Home
to User Manual PDF File
Contents
1. G Shell Power switch EMS button Down Up West East South North 3 3 Receiver function introduction D Q D o Front Back 1 LED Indicator light 2 Label 3 Cable 4 Fastness screws1 5 Fastness screws2 6 Anti vibration spring 7 Installation screw 4 Internal structure 4 1 Transmitter internal structure 1 Transimmitting RF board 2 IP code dip switch 3 Battery contact 4 Micro cpu 5 Power buton 6 EMS button 7 Double speed 8 Indicator light 4 2 Receiver internal structure 1 Receiving RF board 2 Micro cpu 3 Position for function 4 Indicator light 5 Output cable connection 6 Relay 7 AC power input socket 8 1A fuse 9 5A fuse 5 Exterior connection 5 1 6008 5 2 6108 5 3 6208 wiring diagram POWERI POWER COMI UP DOWN EAST WEST CALX COME Q i MAIN e SOUTH NORTH WECAN 6005 POWERI POWERE BI 0 5 COM Oo UPS Oro gt ts DOWN Q o DOWN2 Qt o EAST OQ lt e WEST Oo AUX Ss FUSE COMe ot To a MAIN cso SOUTH C Ox o NORTH at WECAN 6108 POWER POWER2 COMI UP UP2 DOWN DOWN2 EAST WEST E We AUX COMe MAIN SOUTH NORTH N S2 j Oo GO O0 O Note please install the yellow green wire into the equipment shell rightly 7 System configuration 7 1 how to s
2. light is 2 normal but Receiver has not action 1 Confirm the receiver power input is normal 2 Check if AC power fuses and DC power fuse melt if it is necessary turn off the power and use the spare fuse 3 Confirm if the relay output fuse melt if it is necessary please use the spare fuse 4 Send to repair Some actions is not 4 Distance become near 1 Confirm if the relay output fuse melt if it is necessary please use the spare fuse 2 Comfirm if original cable control system works if so find the factory to repair 3 Send to repair 1 Confirm the emitter battery is abundance 2 Confirm the receiver doesn t shield by corresponding metal cover or net 3 Confirm surround has not be interfered by strong wireless 4 Confirm no same frequency interfered which can use to change the channel 5 Send to repair 11 System parameter WECAN 600 two speed series Constant technique parameter The emitter Model WECAN600S WECAN610S WECAN620S Button 6 CSCS 6 Shell ABS enhanced plastics Button mode High reliability two step button Antenna Inside or outside Battery 2pcs AA battery Battery life gt 100hours Frequency 400 460MHz Power Less than 10mW 11 The receiver Model WECAN 600S_ WECAN 610S WECAN 620S Input voltage DC12V DC24V AC85 400V Wiring Pin insert connection Relay 10A 250V Respond time lt 100ms Temperature 20 70 Antenna Outside Encl
3. relay to meet your requirement 5 Operate the emitter farthest to check the signal If the crane action is discotinuous or blind then the operation is very dangerous Note whenever keep your emitter and leave it at proper place Make sure no one can operate it or it will cause very serious aftereffect 9 Transmitter instruction 1 Install the alkalic battery rightly suggest to use above 1600AH battery to make the use time reach 100hours Don t use NIH battery its voltage is only 1 2V 2 Make sure the EMS button is loose and then turn the emitter power button to ON 3 Please pay attention to observe the indicator it will help you to use the remote system The explication between the indicator of the transmitter and the corresponding status LED status Complement Explication Processing method Red light And then operate The transmitter is normal the blink then normal blue light is voltage amp buttons are normal Operation normal close bright communication good And then red blink The transmitter is low Please open the one time after voltage please change the machine after pressing any buttons battery on time change the battery Red light light And then no action There is any button in touch eo done gar lig after pressing any status the transmitter pret ect 3s then depressed and then buttons itself warning open the machine And then normal Weak signal please ensure ar operation blue light is that there is no s
4. WECAN RADIO User Manual User Manual 1 Introduction 2 Safety Instruction 3 Model definition and function introduction 3 1 WECAN seires model definition 3 2 Transmitter function introduction 3 3 Receiver function introduction 4 Internal structure 4 1 Transmitter internal structure 4 2 Receiver internal structure 5 Exterior connection 6 1 Model 6 2 Model 6 3 Model 6 4 Model 7 system CONFIGURATIONS 7 1 how to set jumper functions 7 2 Receiver RF channel setting 7 3 How to set ID codes 7 4 Frequency Channel Table 8 Receiver installatoin 8 1 Installation attention 8 2 Receiver fixation 8 3 System test 9 Transmitter instruction 10 Failure Remove 11 System parameter 1 Introduction WECAN series wireless remote control system which is easily used can be alone applied in different working condition and industry equipment system such as automatic controlling It can ensure safety requirement of modern industry Through man y years professional knowledge and technical experience on Industry communication field we keep on develop and make technology first try to be a leader of wireless remote control field The design of WECAN series wireless remote control system is based on the maximal safeguard for the user and can pass kinds of interfere test of complex condition The major features of WECAN600 series are as follow The system uses advanced microprocessors with highly evolved software that has redun
5. ase choose the allo wed channel to operate We promise most channels is availability and reliability but not every channel if you find wrong channel please trip off to use 7 3 How to set ID codes WECAN600 series have been set ID code each system has exclusive code We can give the right to modify ID code for special customer those customer can obey the operational process to match the transmitter and the receiver at random 7 4 Frequency Channel Table 8 Receiver installatoin 8 1 Installation attention 1 Check and confirm the control traveling crane is normal before installation 2 Turn off the power 3 For the receiver position wherever the crane goes it should not impact any building extruded 4 The receiver should be fixed tightly otherwise it maybe loose and d ropped 5 lt should learn about the crane power and emitter s function settings include relay output to avoid incorrect connection 6 The receiver position should be away from motor transducer and cable at least 3 meters see following picture to avoid unnecessary interference Receiver gt 3M a d er 7 The receiver should be at the top of the electricity box and then take the output cable into the electricity box don t fix the receiver inside the box If must be inside the box then please install the Antenna outside the box gt 3M Right receiver cable Ele box 8 2 Receiver fixation Please install the receiver properly t
6. dant error checking and correcting capabilities to ensure 100 error free transmission decoding and control of all output relays The typical character of WECAN series wireless remote control system includes system parts self diagnosing function the transmitter has com munication check function and know the situation between transmitter and receiver for the detailed see the manual WECAN600 series wireless remote control system no matter transmitter or Receiver can be matched according to sepical opeation for th e detailed see the manual With more than 250 noninterference and different RF channel it can guarantee many machines be operated at the same time in the same area The Degrees of protection of receiver and transmitter can be above IP65 with good configuration The transmitter can be used outside completely against the water come in as the degrees of protection of water proof and dust proof can be reached IP 66 The receiver is ensure to be used in bad environment as IP65 The life of batteries can be used more with lower transmit power Use 2 pcs AA batteries in the trasmitter to make sure at least transmit 100 hours in the smallest distance 2 Safety Instruction WECAN600 series wireless remote control system are relatively simple to use how ever please read manual before installation and operate with correct procedure It can bring good effect with correct installtion and use WECAN600 series wireless remote control s
7. et the jumper The receiver has 3 function positions details on the picture you can set your system functions to meet your different requirements the function settings is below 1 Special function setting Join the terminal to the receiver port P3 the relay action for button B is lock form On the contrary the relay action will be action by pressing 2 Automatic shutoff setting Join the terminal to the receiver port P2 the man relay will be automatic breaken after 600s by the receiver if no signal for the open the receiver won t answer any command On the contrary the automatic function of the receiver will be responsive 3 Masterslave setting Join the terminal to the receiver port P1 then it is master receiver the transmitter will control it directly On the contrary the receiver is slave receiver you will switch to this receiver by A button You can change the port P1 to make one is master or slave This function is only for 600A 610A and 620A Note please shut off the receiver power first and change the port then it is valid to open the receiver 7 2 Receiver RF channel setting Both the transmitter and the receiver have a ID code dip switch if this is changed the RF channel of the transmitter and the receiver will be changed Note 1 Finishing ID code dip switch setting then cut off the equipment it will be effective after electricity 2 WECAN series supply more than 256 channels to you ple
8. hielding or Weak signal please bright interferent between the attention to use right transmitter and the receiver 4 Every time you press EMS button the emitter will send stop signal to the receive r continously the signal keeps 3 seconds then stop sending you must press EMS button to continue If you turn the power to OFF then the EMS is invalid 5 Before close the power of the emitter please press the red EMS button then turn the power button to OFF Don t close the power directly it won t disconnect the relay and keeping on 6 Button interlock the emitter has the function when you press UP button then the emitter won t respond DOWN command 7 Change the battery please change the battery on time when the voltage is low you can open the battery cover take out them and put new battery 10 Failure Remove 10 If the remote control is not working please remove the failure according the following explain When the controller can t work normally pressing the emitter buttons the receiver has not action please check the failure by the following steps Item Failure description Method Emitter LED light doesn t shine Receiver has no action 1 Confirm if the battery power is normal a Check the battery directions b Check the battery box directions c Check the battery capacity d Check if the tube is break or uncertain close 2 send to repair Emitter LED
9. o avoid the shake 6 amp Installation of the shockproof spring 8 3 System test Notice please sure that all wiring is right and under good protection all screws are t ight fix the cable between the reciever and the crane to avoid the cable be short by the crane shake Then open the crane power supply 1 Test process First loosen the EMS button method rotate the button 1 4 circle clockwise it will bounce automatic Then rotate the left rotory switch to ON position the center indicator will be red later turn to blue Note 1 when you press the EMS button you must redo the above operation to open the receiver loosen the EMS and rotate the switch to ON position Note 2 don t press any button of the transmitter during the power on or it will make the 9 transmitter into protection not sending any signal Note 3 after the power on the transmitter appear red 3 seconds then turn to blue or sparkle One time on red then one time on blue etc two different condition details see the manual 2 Under default state the control relay of the receiver will disconnect after 10minutes starting from not any signal If you don t need this function give a suggestion for you move the relevant connecting pieces then the control relay keep contact until receiving the EMS signal Details operation see the manual 3 Make sure that the contactor is off after pressing the EMS button 4 Test each function of the
10. osure IP66 RF mode Frequency modulation Range 100 meter Enclosure IP66 Notice the environment is bad or distance more than 100m please add the antenna Attention 1 Please read the manual before installation and usage 2 Please close the main power when you install and maintain the remote control to avoid touch electricity 3 The transmitter is lay at safety place nobody can push the button to avoid accident happen 4 Controlable crane should has mainpower relay limit switch and other safety facilities 5 Please stop using when there is lightning strike or disturbance non training person don t open the machine to avoid break it 6 This manual is for user reference please contact us for details 7 We hold the right to amend the machine and manual without notice operation manual is not confirmed to the machine please enquiry our company 12
11. ystem The following points should be followed when using 1 Check the transmitter casing and pushbuttons daily Should any damage be found the unit should be removed from service 2 The transmitter voltage should be checked If the voltage is low red status light blinking or completely off the batteries should be replaced If t he transmitter is not used for a long time please take out the batteries and keep it safe 3 The red emergercy stop button should be checked daily to ensure it is in proper working If any question the receiver should be prohitted to use 4 Turn the power switch off after each use to avoid the mis operation 5 Do not use the same RF channel and ID code as any other system in use at the same facility or test within distance 6 Never operate a crane or equipment with two transmitters at the same tim e with the same RF channel and ID code 3 Model definition and function introduction 3 1 WECAN seires model definition WECAN 6 Affixal function The sort of model Serial number of design Sign of brand 3 2 Transmitter function introduction WECAN600S 5 one speed buttons D D 1 5 O 8 9 Shell Power switch EMS button Down Up West East South North WECAN610S 2 two speed buttons 4 one speed busttons Attached drawing and instruction WECAN 600 Shell Power switch EMS button Down Up West East South North WECAN620S 5 two speed buttons Attached drawing and instruction
Download Pdf Manuals