1. lumen8 PF LED Profile User Manual Order codes ELUM094 100W 3200K WW Version ELUMO95 100W 6000K CW Version ELUMO96 150W 3200K WW Version ELUMO97 150W 6000K CW Version Lumen8 Safety advice WARNING FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START UP e Before your initial start up please make sure that there is no damage caused during transportation e Should there be any damage consult your dealer and do not use the equipment e To maintain the equipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written in this manual e Please note that damages caused by user modifications to this equipment are not subject to warranty CAUTION CAUTION TAKE CARE USING KEEP THIS EQUIPMENT THIS EQUIPMENT AWAY FROM RAIN MOISTURE AND LIQUIDS HIGH VOLTAGERISK OF ELECTRIC SHOCK IMPORTANT The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorised modification to the equipment e Never let the power cable come into contact with other If the equipment is dropped or damaged disconnect the cables Handle the power cable and all mains voltage mains power supply immediately and have a qualified connections with particular caution engineer inspect the equipment before operating again e Never remove warning or inf
2. input output see image below Further DMX cables can be purchased from all good sound and lighting suppliers or Pro Light Concepts dealers Please quote CABL10 2m CABL11 5m CABL12 10m Note DMX cable must be daisy chained and cannot be split www prolight co uk PF LED Profile User Manual 6 elumen8 DMX setup Notice Be sure to follow the diagrams below when making your own cables Do not connect the cables shield conductor to the ground lug or allow the shield conductor to come in contact with the XLRs outer casing Grounding the shield could cause a short circuit and erratic behaviour common DMX 512 out 3 pin XLR DMX 512 in 3 pin XLR Soc PS A KE XLR MALE SOCKET XLR FEMALE SOCKET XLR Pin Configuration 2 cold 1 ground 1 ground 2 cold I Pin 1 Ground o Pin 2 Negative 3Hot 3 Hot Special note Line termination When longer runs of cable are used Termination reduces signal transmission you may need to use a terminator on problems and interference It is always the last unit to avoid erratic behaviour advisable to connect a DMX terminal resistance 120 Ohm 1 4 W between pin 2 Using a cable terminator will decrease DMX and pin 3 DMX of the last fixture the possibilities of erratic behaviour 3 pin Order ref CABL9O 5 pin Order ref CABL89 5 pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtu
3. curve e 3 push button menu with LCD display e PowerCON input output e 5 Pin XLR input output e Temperature controlled fan cooling e Handle on rear panel e Filter frame included e Supplied with gobo holder Specifications Power consumption Power consumption PF LED Profile 120W 100W Version 170W 150W Version Power supply 100 240V 50 60Hz Dimensions 320 x 262 x 590mm Weight 9 6kg Order code ELUMO94 100W WW Version Order code ELUMO95 100W CW Version Order code ELUMO96 150W WW Version Order code ELUMO97 150W CW Version 100W WW 590mm 25 Lux 14760 3700 1640 925 592 37 Lux 9800 2450 1090 613 392 100W CW 25 Lux 15200 3800 1690 950 608 37 Lux 9000 2250 1000 563 360 150W WW 25 Lux 21000 5250 2330 1310 840 37 Lux 13720 3430 1520 856 548 150W CW 25 Lux 21200 5300 2360 1130 848 e 37 Lux 12600 3150 1400 788 504 9 m NN A WA ri I Om 1m 2m 3m 4m 5m www prolight co uk PF LED Profile User Manual 3 Lumen8 Technical specifications 01 Earth point 02 LCD display 03 On Off switch 04 Function buttons 05 5 Pin DMX input 06 5 Pin DMX output 07 PowerCON input 08 PowerCON output 09 Fuse T3 15A 250V In the box 1 xfixture 1 x 13A powerCON mains cable 8 1 x user manual lumen8 PF Profile www prolight co uk Operating instructions DMX channel mode Operating in DMX cont
4. ed do not overlap E g the next unit in the chain starts at 107 DMX 512 DMX Digital Multiplex is a universal protocol used as a form of communication between intelligent fixtures and controllers A DMX controller sends DMX data instructions form the controller to the fixture DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a data out terminal DMX linking DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain DATA cable DMX cable requirements for DMX operation This fixture can be controlled via DMX 512 protocol The DMX address is set on the back of the unit Your unit and your DMX controller require a standard 3 pin XLR connector for data
5. ormative labels from the unit If the equipment has been exposed to drastic Do not open the equipment and do not modify the unit temperature fluctuation e g after transportation do not connect power or switch it on immediately The arising condensation might damage the equipment Leave the equipment switched off until it has reached room temperature Do not connect this equipment to a dimmer pack e Do not switch the equipment on and off in short intervals as this will reduce the system s life e Only use the equipment indoors If your product fails to function correctly stop use Do not expose to flammable sources liquids or gases immediately Pack the unit securely preferably in the e Always disconnect the power from the mains when original packing material and return it to your Pro Light equipment is not in use or before cleaning Only handle dealer for service the power cable by the plug Never pull out the plug by pulling the power cable Repairs servicing and power connection must only be e Make sure that the available voltage is between carried out by a qualified technician THIS UNIT CONTAINS 100 240V 50 60Hz NO USER SERVICEABLE PARTS e Make sure that the power cable is never crimped or damaged Check the equipment and the power cable periodically Only use fuses of same type and rating WARRANTY Two year from date of purchase OPERATING DETERMINATIONS If this equipment is operated in any othe
6. r way than those described in this manual the product may suffer damage and the warranty becomes void Incorrect operation may lead to danger e g short circuit burns and electric shocks etc Do not endanger your own safety and the safety of others Incorrect installation or use can cause serious damage to people and or property www prolight co uk PF LED Profile User Manual 2 lumen8 Product overview 8 technical specifications PF LED Profile The PF LED Profile is loaded with a 100W 150W cool warm white LED producing an output similar to a 650W 1000W lamp Control of the unit is facilitated via a 3 button menu and LCD display whilst the beam angle can be manually adjusted between 25 and 37 Eight dimmer curves are included for maximum flexibility The whole fixture is enclosed in a robust chassis featuring four framing shutters gobo slot with holder and is supplied with filter frame e 1x 100W warm white COB LED 3200K ELUM094 e 1 x 100W cool white COB LED 6000K ELUMO95 e 1x 150W warm white COB LED 3200K ELUM096 e 1x 150W cool white COB LED 6000K ELUMO97 e Manually adjustable beam angle 25 37 e CRI gt 95 e Glass condenser optic system with zoom and focus adjustment e 1 6kHz refresh rate e Beam framing shutters e Gobo slot Gobo size 70mm e DMX channels 1 or 2 selectable e 0 100 dimming e 4 dimming curves in both LED and halogen profiles Linear square law inverse square law and S
7. res may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The diagram below details the correct cable conversion 5 pin XLR socket Pin 1 GND screen 3 pin XLR socket Pin 2 Signal CHID Pin a GND screen Pin 3 Signal Pin 2 Signal Pin 4 N C Pin 3 Signal Pin 5 N C 5 pin XLR socket Pin 1 GND screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C 3 pin XLR socket Pin 1 GND screen Pin 2 Signal Pin 3 Signal gt B A E www prolight co uk PF LED Profile User Manual 7 lumen8 WEEE notice Correct Disposal of this Product Waste Electrical amp Electronic Equipment Applicable in the European Union and other European countries SS with separate collection systems This marking shown on the product or its literature indicates that it should not be disposed with other household wastes at the end of its working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally safe recycling Business u
8. rol mode gives the user the greatest flexibility when it comes to customising or creating a show In this mode you will be able to control each individual trait of the fixture and each fixture independently To access the 1 channel DMX mode press the MENU button on the rear of the unit to show DMX 1CH on the LCD display The fixture is now in 1 Channel mode Now use the UP and DOWN buttons to set the desired DMX address for the 1 Channel mode To access the 2 channel DMX mode press the MENU button on the rear of the unit to show DMX 2CH on the LCD display The fixture is now in 2 Channel mode Now use the UP and DOWN buttons to set the desired DMX address for the 2 Channel mode To exit out of any of the above options press the MENU button www prolight co uk PF LED Profile User Manual 4 lumen8 1 channel mode Please note Dimming curves for 1 000 255 Master dimmer 1 channel mode can be set via 0 100 internal menu 2 channel mode 1 2 000 255 Master dimmer 0 100 A 105 134 S curve Halogen dimming curve 135 164 Linear LED dimming curve 165 194 Square LED dimming curve 195 224 Inverse Square LED dimming curve 225 255 S curve LED dimming curve Manual dimming mode To access the sound active mode press the MENU button on the rear of the unit to show WhiteSet on the LCD display The unit is now in manual dimming mode Now
9. sers should contact their supplier and check the terms and conditions of the purchase contract This product should not be mixed with other commercial wastes for disposal CE www prolight co uk PF LED Profile User Manual 8
10. use the UP and DOWN buttons to set the brightness from 0 255 0 LED off 255 LED at full brightness To exit out of any of the above options press the MODE button Dimming curves To access the units dimmer curves press the MENU button on the rear of the unit to show Led Linear on the LCD display Now use the UP and DOWN buttons to set the dimming curve required Led Linear LED Linear dimming curve Led Square LED Square dimming curve Led InvSquar LED Inverse Square dimming curve Led S Curve LED S Curve dimming curve Halgen Linear Halogen Linear dimming curve Halgen Square Halogen Square dimming curve Halgen InvSquar Halogen Inverse Square dimming curve Halgen S Curve Halogen S Curve dimming curve To exit out of any of the above options press the MENU button www prolight co uk PF LED Profile User Manual 5 lumen8 DMX setup Setting the DMX address The DMX mode enables the use of a universal DMX controller Each fixture requires a start address from 1 511 Afixture requiring one or more channels for control begins to read the data on the channel indicated by the start address For example a fixture that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100 would read data from channels 100 101 102 103 104 105 and 106 Choose a start address so that the channels us

Download Pdf Manuals

image

Related Search

Related Contents

シーリングプレート取外し工具 取扱説明書  PV n°5  平成17年度成果報告書はこちら - JCCLS-特定非営利活動法人 日本  Télécharger la recette  CleanTelligent User Manual  Configurable Logic Cell (CLC) Configuration Tool User's Guide  PS/PCL/UFR II Druckerhandbuch  Conceptronic CLHDMIMCHDMI video converter  Honeywell 6280 User Guide  Socket Mobile CHS Series 7 QX Stand  