Home

CORRAL6021A-User Manual.cdr

image

Contents

1. CORRAL6021A RFID middle range integrative reader User Manual First Brief introduction of CORRAL6021A Reader 1 Use of CORRAL6021A Reader 2 Main function of CORRAL6021A Reader 3 Technical parameter Second the configuration and interface instruction 1 Configuration Instruction of every part of CORRAL6021A Reader 2 Instruction of the interface 3 Tag operation 4 Work mode 5 Interfacing identification Third Settling of CORRAL6021A reader Fourth Fitting of CORRAL6021A Reader 1 Fitting mode of CORRAL6021A Reader 2 Fixture and height adjustment of CORRAL6021A Reader 3 Azimuth angle adjustment of CORRAL6021A Reader Fifth demo program instruction of CORRAL6021A Reader Sixth The second exploitation of CORRAL6021A Reader Seventh Contact mode First brief instruction of CORRAL6021A Reader The products can be compatible with multi protocol small volume quickly read and multi tag identification The round polar antenna is no limit of direction for tag water proof Meanwhile it can be used widely in RFID systems the mainly applying sites are 1 Logistics and warehouse Management goods flow warehouse management and the flowing management of mail parcel and luggage 2 Intelligent parking Management Parking management and automatic charge 3 Productive lines Management Production process fixed identification 4 Product counterfeit proof inspection Using memorizer s write protect functions inside tags to ident
2. CTING l Comm Port coma x Baudrate 115200 Addr Code Generi RFE SETTINGS Power a dBm WordPtr Eo ea Hordint tosh Tni een Picture16 demo software interface Choose the COM communication port and baud rate you use and choose the right reader address Click Connect to establish connection with the reader After successful connection the right and left information frames will indicate the successful connection and the edition NO of the reader firmware And you can operate all demos Sixth the second exploitation of CORRAL6021A Users can make the second exploitation to the application software reader according to the need We provide the exploitation bag basis on the C language which supports the environment of VC vo Dephi and C Buider and so on Please make reference to the lt lt NRreader SDK instruction gt gt about the use of exploitation tag
3. OMM SETTING ConmPort i r Reader Addr defar w Pomier faeoob x Peetnin Enable Trston Effect Time m ig Opration Info Default Cnery met Restart E Active Trans Passive Trans e Response Trans Picture 5 fitting software interface 1interface setting Interface setting includes interface choice band rate setting and address choice of reader The address of reader is from 1to 240 Only choosing the right address can reader establishes communication Besides you can choose default which is fit for all reader after clicking Connect button PC and reader establish communication connecting After software and reader connecting it reads the present working parameter of reader at once automatically Interface after connecting is like the following picture indicated RF SETTING ANTENNA READ INDICATE BUZZER Y LED WORE MODE C COMMAND Power 29 am Freq AMERICA TIMING READ TIMING INTERVAL TRIGGER READ Interval 100ms WIEGAND SETTING R545 SETTING Output Mun fode Active Trans OUTPUT FORT Fort frsass CommPart eom Frotocal Common Reader Addr defan COMM SETTING Fulse Width 00 38 Passive Trans pS PRECHP Baudrate S600 x a ean T 5 B Treine Saas Pulse Periods ms Response Trans Discon Effect Time p55 s Oprati on Inf a Get Reader Para
4. cation 6 Read indicate Buzzer and LED are optional for reader to choose users can choose them according to demand 7 Timing interval This frame includes setting the frequency of reading tag namely setting time for cycle reading and the interfacing identification Setting time for cycle reading can be 10ms 1000ms Users can choose interfacing identification and set the effective time for interfacing identification If no need of setting effective time fill in O instead 7 Communication out port parameter setting Setting data out of communication pork and other agreement When choosing RS485 communication agreement Syns agreement and common transmission agreement are optional The format of common transmission agreements are like the predescription Please make reference to the Syns controller information about Syns agreement When choosing Wiegand interface you can choose Wiegand26 or Wiegand34 agreement OUTPUT PORT Fort RS485 Comm ore SUT 1S OUTPUT FORT Fort Wiegand Protocal EREE is Wiegand m FRECHE m FRECHE Picture 10 interface setting 8 RS485 setting R465 SETTING it Active Trans Passive Trans Response Trans Picture 11 interface setting This frame is used for setting the Wiegand interface parameter Include Wiegand output times and signal format Wiegand signal format needs setting Wiegand pulse breath means low impulse breath and code element cycle means
5. g destroy tag after that the tag can t be used again 4 Work mode Command read in this work mode reader works under the control of PC or other controller Reader can controller can communicate through RS232 RS485or one of the big net interfaces This kind of working support all the function that the second exploitation bag supplies Il timing read reader reads card in some cycle can be settled the data be read can be output through appointed communication interface This mode is only for reading to the tag operation Il overwrite working TRIGGER READ when the touching off port inputs low voltage reader begins to read card in cycle and shut off in a period of time Sinterfacing identification Interfacing identification is designed for reducing the prolixity of the data that reader uploads If choosing the function reader will only upload a set of data when reader reads the same card in multi connection Namely that if the interval time of interfacing reading two times exceeds the effective time reader won t process interfacing identification So users should choose it according special demand Third the fitting of CORRAL6021Areader Our company provides Configure exe programs for the fitting of the working parameter of the reader the parameter fitting program is like the following picture WORE MODE COMMAND E TIMING READ C TRIGGER PEAD Dutput Hun Pulse Width Pulse Periods f ms C
6. he controller machine ms eee Sius In order to improve the of the reliability of data transmission the reader supply multi transmission function namely when reading one tag the Wiegand interface will be multi transmission in interval in some time T he transmission tomes can be 1 to 3 the transmission interval can be settled when display software 3 Tag operation 1SQ18000 6B tag 1 multi tag identification search all the tags in the rang of antenna radicalization and read their octet UID 2 multi tag reading search all the tags in the rang of antenna radicalization and read the octet data from the beginning of the appointed address 3 single tag writing write data of one tag at the appointed tag address 4 single tag locking lockdown the data of the appointed tag address After that it won t be overwritten 5 Inquire about the Single tag locking inquire about the locking state of the appointed address ll EPC GEN2 1S018000 6C tag 1 Multi tag identification search all the tags in the rang of antenna radicalization and read their EPC the longest of EPC of EPCGENZ can reach 256 digits now support 96 digits 2 Single tag initialization define the EPC longness of the tag popularly 96 digits 3 Single tag writing read in the EPC of the tag one piece 16 digits one time 4 Single tag locking lock down the EPC of the tag after that the EPC of the tag can t be overwritten 5 Single tag destroyin
7. ify true false of products 5Other fields widely used in club management library school consumption management time management dinner management and pool management 1 the use of CORRAL6021A Reader It can be used for goods identification and data collection specially used widely in the following areas with its speciality 1 Transportation management road and railway transportation management and container transportation management and so on 2 motor vehicles management use it to police station and transport department supervise and manage the motor vehicles 3 roadand bridge charge as the product is able to read the tag data quickly in long distance road rate and bridge can be charged without stopping Vehicles 4 Customs management the management for goods to pass and transit the customs and vehicles Logistics and warehouse Management Goods flow warehouse management and the flowing management of mail parcel luggage 5 Parking management in order to make management and charge automation 6 Doors control management including vehicles and people to pass in and out management 6 Craft work manufacture flow supervise parts in the whole manufacture flow 2 the main function of CORRAL6021A Reader 1 A waken the tag Only the tags that be awaken can communicate with the reader and prevent the disturbing of those tags out of the system thereby confirm the credibility and nicety of the exchange information between the
8. ivation line instruction of the reader Mainframe of the reader The stationary barrier of the reader 2 interface instruction of the reader The hookup of CORRAL6021A Electricle interface RS232 RS485 TRIGGER WIEGAND source Color red black white purple gray brown yellow orange green blue pink green Define 9V GNE TX RX GND A B TRIGGER GND DATAO DATA GND 2 1 RS232 The reader provide RS232 communication interface for connecting communication with control mainframe commonly the PC machine the data format of the RS232 interface is 8 daa bits a star bit and a stop bit without parity bit 9600 19200 38400 57600 and 115200 are the choices for data modulus RS232 communication interface support the fitting parameter demonstration program all the second exploitation bag function of the single communication of the reader 2 2 RS485 Model A and B reader of DRF series provide RS485 communication interface which can connect with interface of the PC machine in the condition of using RS232 KS485 changer for changing RS485 interface supports all functions that RS232 supports besides RS485 a interface for tag data output when using theRS485 to upload tag data it can choose three kins of modes for transmission Initiative uploading upload data immediately when reader reads the tag Passivity uploading it doesn t upload data when reader reads the tag but wait until the mainframe
9. meters ETA Restart READER ADDR Addy 212 Query Picture sixth setting interface 3 Reader address rejigger fuers Picture 7 setting interface If you want to amend the address of the reader you can choose the new address under the frame of the amending address column of the reader Then click the set button The new address will be effective when reader reposition 4 work mode choice TINTES BEAD TRIGGER READ Picture8 setting interface Users can configure the work mode of the reader through single choosing frame When choosing the command reader can set radio frequency parameter and antenna multicenter matching style at the same time and other part become gray When choosing timing or touching off mode Reader can set the parameter of radio frequency timer and communication interface If choosing touching off mode it can set the parameter of the trigger We will describe them one by on as the following ee dEm Freq AMERICA Picture 9 setting interface Users can set the power and frequency of the radio frequency according application need The largest power parameter can be 30dBm You can choose China standard 920MHZ 925MHZ or FCC 902MHZ 928MHZ as the frequency of radio frequency other frequency bands need customize 5 antenna setting When using multicenter readers you can choose antenna Choosing the corresponding antenna in the check box means antenna invo
10. of letter L it demands the dia of L shape or dragon door shape crutch is from 60 to 80mm while rail dia 60 to 60mm lt is best to sue stain steel material that more than 12 to 20mm thick Fix the CORRAL6021A reader to the rail that near the middle carriage drive The height that the rail to the ground is needed to adjust from 3 5m to 4 0m according to the height of vehicle 3 the azimuth adjustment of the reader CORRAL6021A reader mle 60 75 2 072 2m Picture 15 the sketch map of the azimuth angle adjustment of CORRAL6021Areader Antenna angular indicates the included angle between the antenna and level when the antenna inclines to the ground Azimuth angle of antenna indicates the deviation angle when antenna deflects to the direction of carriage drive Fifth The demo program instruction pf CORRAL6021A The demo program of the reader provides the contend of all kinds of operation to the tag and parameter setting of radio frequency Users can evaluate the function of the function of the reader through this demo program of consid er to make the second exploitation of the reader The demo program of the reader includes DEMO exe and MR915ApiV10 dll Please put this two parts in the same file catalog then double click it will begin to circulate the interface is like the following picture indicated die UHF INTERROGATOR DEMO Ef x emr READ AND WRITE Eytekddr fi Brytelnt CONNE
11. reader and the tag of the system 2 read the tag data not only can it read the ID number of the tag but also the data of the appointed tag storage area not only can it read the single tag data but also multi tag data of the antenna wave synchronously 3 real in tag data it can read in data to the appointed tag storage area 4 It can connect with the control equipment with standard W26 or W34 interface without exploitation therefore convenient for use 5 Connect the controller of PC machine through the communication interface to process the data communication and exchange and to provide SDK exploitation bag so as to make customers exploit for use again 3 Technology parameter of the CORRAL6021A 1 operation frequency China standard 920 925MHz FCC standard 902 928MHz or Others frequency band can be tailor made as per required Card reading distance identify distance and adjust range 1 4 meters 2 card reading sense twin pole mode technology 3 card reading time single tag 54ID no lt 6ms 3 Operation voltage DC 9V 4 Operation temperature 20 C 80 C 5 Storage temperature 40 C 125 C Second the configuration and interface instruction of CORRAL6021A Reader Second configuration and interface instruction of CORRAL6021A 1 every part of reader instruction Picture2 co nfiguration inst ruction of CORRAL6021A 1 instruction of every part of the reader Derivation instruction of the reader The der
12. the time of a bit data After every function choosing click SET button The successful setting parameter will be effective when reader repositions Suers can click Restar button to make reader reposition Fourth The fitting of CORRAL6021A Reader 1 1 fitting modes of the reader T Picture 13skatch map of fitting effect There are two kind of modes that CORRAL6021A crutch fitting frank fitting that like the figure 1 and crutch fitting like the shape of letter L as the following picture indicated They can be choose according to the application need and locale practice Generally the reading distance of frank fitting is nearer but fitted simply while crutch fitting farrer but complex CORRAL6021AReader CORRAL6021A Reader IB Pe ee El Frank fitting like the figure 1 crutch fitting like the letterL Picture 14the fitting modes of the reader 2 the fixation and height adjustment of the reader When frank fitting it demands that the crutch dia of the reader 50 to 60mm while length2 2m Using stain steel material that more than 1 3m thick is the best choice Fix the reader to the top of the crutch with the self provided fastening pin in the casing of CORRAL6021A reader Adjust the height from the center of CORRAL6021A reader to the level of carriage way according to the vehicle style mainly indicates the oversize vehicle and landauter generally about 2 0m from 1 2m to 2 2m When crutch top fitting like the shape
13. to fetch data Reaponsion transmission after reader reads aoe tag it will upload data repeated until receives the response velemen from the mainframe How RS485 uploads data format is like the following tables head 0x02 High Low byte One octor ASCII 0x03 One byte byte byte Thereinto the method of checkout is for the difference checkout of all the frontal bytes The mainframe to get the order frame format of data is like the following table showing Identification module address Order No head The mainframe to get the response frame is like the following table showing 2 3 Wiegand interface Reader supply one Wiegand data interface users can choose Wiegand26 or Wiegand34 communication agreement the data format of these two kinds of agreement is like the following table showing Table one Wiegand26 format The formal 12 digits The latter 12 digits Thereinto PO is the even of the formal 12 digits PI is the odd of the latter 12 digits 34 format The formal 16 digits The latter 16 digits 1 Thereinto POis the even of the formal 16digits PI is the odd of the latter 16 digits Wiegand interface is composed of 3 lines the negative pulse of the first line indicates 3 0 anothere line indicates 1 and the third one is ground electrode The typical format of every data is like the following picture showing Of course users can settle the data formal of the Wiegand interface according the special demand of t

Download Pdf Manuals

image

Related Search

Related Contents

ioCONTROL USER'S GUIDE    AC400S  Cyber Cafés, um Manual de Instruções      Philips 32PFL3258H 32" Full HD Smart TV Black    Requirements for the ongoing assessment of treatment system  

Copyright © All rights reserved.
Failed to retrieve file