Home
Quick Start Guide
Contents
1. Quick Start Guide www DiveRite com Conso Ne Camper Qs 0142011 Congratulations on your Dive Rite NiTek Q purchase This Quick Start Guide is intended to familiarize you with the basic functions ofthis computer Itis nota substitute for the user manual found in our brary twv Divete om You MUST read the Nek Q user manualin its entirety before diving this product The NTek Qis an electronic device and electronic devices can fal NEVER clive this computer without a back up device or dive tables Before diving your NTek Q the battery must be charged The Q can be charged with either the included AC charger or from any USB connector To access the charging port use a coin and turn the cap a quarter tum counter clockwise to align the groove the battery cap with the groove on the computer case When this groove is aligned the battery cap is longer sealed lug the charger into an AC outlet or USB connection and then into the port on the computer The battery symbol s animated to Indicate charging Periodically disconnect the charging cable and check the number of bars a solid battery symbol indicates a ful charge Upon fuli charge reinsert the battery cap and using a coin turn the battery cap a quarter tur clockwise to seal Donot dive the computer unless the battery sealed Getting Started The NiTek Q has an always on OLED screen that returns to a sleep mode hibernation after 10 minutes PRES
2. Decompression Warning Deco Stop Violation Warning FREEDOM OF CHOICE This two gas Nitrox dive computer gives you the freedom to choose additional features as your sills row and your equipment changes The Q diver can upgrade to normoxic or hypoxic Trimix CCR digital compass and custom gradient factos You only pay for the features you will use and can upgrade to ad ditional features at any time Contact us at Dive Rite at Qunlocks diverite com to upgrade your and then simply connect to any standard USB port to unlock the features you have added SUPPORT All Dive Rite products receive our com mitment to excellence in customer service from your fellow divers Contact us at support diverite com or phone at 800 495 1046 M F 9A 4P ES Using Your NiTek Q Thefolowingisa checklist of general things you should pay attention to before during and after a dive Before A Dive Be surethe computers charged The Q can be charged ftom any USB connection or ftom indus charger Ensure that the USB apis secure Ceci thatthe proper me and date are set Check that the proper mnes and modes are se Review the dive plan for mauimum dept times and for mbesyou plan to use During A Dive Montor your Tek Q throughout the dve for depth and time Monto the Presiune Gas nue PGT and Oxygen Ln Instr OL bar graphs Hedat sams or warnings Follow the no decompression itso complet any displayed decompression schedule
3. After ADive Montor Surface Interval Tf making another de Folow desaturation and no fy guidelines Review your dive using the log book and profi modes NOTE The hematin atter Tories The screen dilay isthe biggest rain on he bat tep Jovan pan e npr ta desp ype eb Scd Tori e copper gt DIVE RITE 800 495 1046 www DiveRite com ine dbs Dre pe e dia D Tt Noam notre rae vete oe mota parois haters weer ers Laer die DWE ARE
4. scroll to the Conservatism Gradient Factor option SET PRESS the 8 button to choose your GF CONS 2 30 75 defaut CONS 1 40 100 CONS o 75 95 PRESS the A button to select your GF The computer v li then scroll to the fishing Impe HalMetric option Imperial Metric PRESS the Bbuttonto toggle to either ft mpe Fal orm Metri PRESS the A button set your option The computer will then scroll to the sampling rate option for your dive log Sampling Rate orLog Bookand Profi PRESS theBbuttonto toggle to either 15 sec ond or 30 seconds PRESS the A button to set your selection The computer wili then scroll to the calibration option foreither FRESH or SEA water FRESH or SEA PRESS theBbuttonto toggle to either FRESH water or SEA PRESS the A button to set your option The computer wili then advance to additional Brightness Control Upon entering the SET sereen MIX 1 is flashing PRESS the A button repeatedly untl the Brightness mumberis fishing PRESS the 8 button to change the brightness When finished press the A button to lackin your selection Additional Screens tos Were mor PRESS the A butontoscol toaditionalceens PLAN displays the NDL no decompression limit based on your programmed gasses fora dive Conservatism Gradient Factors The NiTek Q uses the Buhiman 2116 algorithm a default gradient factor of 30 75 and tw
5. EA water option and brightness control Programming Gas Mixes PRESS the B button The number will be flashing 1 To select Mix 1 PRESS the A button which v ll Jockin your frst mixand then scroll to the Poz alarm option PRESS the B button to toggle between 14and 16 Poz alarm Menus SET Mode continued PRESS the A button to set your PO alarm The computer will automatically advance to your 02 gas option PRESS the B button to select your 02 Upto2 derent gas mises can be programmed buit ouare only 1 mae you oniy need to set MIX Additional Settings Maximum Depth Alm smu eine Alam Fetes Water TGenatbnvGdertfecor Conto SET Maximum Depth and Time Alarms Ifyou do not wish to set a Maximum Depth Alarm continue to pres the A button to scroll through this menu youwish to seta Depth Alarm PRESS the B button until your reach your desired maximum depth PRESS the A button to select the depth and PRESS the B button to select ON The com puter will advance to the Maximum Dive Time Alarm option Ifyou donot wish to seta Maximum Dive Time Alarm continue to press the A button to scroll through this menu Ifyou wish to seta DiveTime Alarm PRESS the button until your reach your desired dive time PRESS the A button to select the time and PRESS the B button to select ON The com ter Will
6. S either A or B button to bring it out of hibernation The Home screen shows the serial number and the software version The Surface screen is the default sereen which will appear ten seconds following activation The Surface screen displays battery charge status date time choice of FRESH water or SEA calibration and the first gas mix you will use when diving mes Navigating the menus of the Q is intuitive TEN the left A button and right B button are 18 0 O16 Used in the same way across all screens Surface Mode Screen PRESS A to scroll PRESS B to select PRESS A to confirm the choice and advance to the next option p Toretum othe Surface Mode Screen mox x DEM PRESS and hold the A button for 2 3 seconds ser 18 jj SET Mode Seen Home Screen 07 12 06 19 If no buttons are pressed within about 20 sec onds the screen vall retur tothe surface mode Toretur the computer to hibernation PRESS the B button for 23 seconds To getto the SET Mode Screen from the Sur face Mode Screen PRESS the A button Menus Dive Option SET Mode The dive option SET and display mode is where all dive settings are programmed including your Poz alarm for each gas either 1 4 or 1 6 02 an optional maximum depth alarm a maxi mum dive time alarm conservatism gradient factor options a sampling rate for the lag book either 15 or 30 second intervals the FRESH or S
7. o addit ional pre set GF settings to choose from that alow for deep stops ar shallow stops PRESS theBbuttonto activate the screen tinue pressing the B button to change depths foryour NDL LOG is where your logged dives are stored PRESS the B buton to activate the screen Continue pressing the B button to sal through logged dives PROFILE is where graphic profiles of each dive are stored PRESS theBbutento activate the screen Con tinue pressing the B button toscolthiooghyour logged profe PC Workbench dive software allows the Q diver to perform dive planning or gas mixes on either a PC or An optional upgrade to the Workbench Log book allows you to upload dive data and view dive profiles Contact Dive Rite at Qunlocksadiverite com for information about the Workbench upgrade TIME From the Surface Mode Screen scroll through the menus using the A button to the TIME screen The seconds will be flashing PRESS the B button to reset to 00 PRESS the A button to scroll to minutes theBbuttonto set the accurate time Continue setting hours year day and month using the A and B buttons as directed above To change to 24 hour time PRESS the B button when PM flashes Dive Mode Dive Computer Mode The Dive Computer Mode is automatically entered when the computer enters the water It begins performing dive calculations once you descend below 5 feet 1 5m While in diving mode the compute
8. r calculates and displays Information about your dive and prompts you with safety stop information and warnings if needed When diving there are two screens you can toggle between and you can switch to different gas mixes when needed 75 24 ad Qu i z Hr Bar 15 Bar Tar Unde soe Primary Underwater Screen Displays depth re maining no decompression time dive time max depth mix Po and Da percentage mix number and PGT pressure gas in tissue and OLI oxygen limit indicator bar graphs graphic representations of your CNS cock To get to the Second Underwater Screen PRESS and hold the Button Release the B but ton to return to the Primary Underwater Screen 25 2 00037 a Second Underwater Screen Displays curent depth dive time temperature and conservatism gradient factor Changing Gas Mixes PRESS the A button and the MIK number wil fash PRESS the B button as needed toselectmikmum ber Qa and Poa wili change per the programmed mix PRESS the A button to lock the mature and retum tothe primary screen Ambe cannot be locked init causes yout exceed pre programmed 140r 155 ATM WARNINGS There are several visual warnings you should be alert to and become familiar with Refer to your NiTek Q user manual at www DiveRite com for additional information These indude Ascent Rate Warning Limit Waring PGT Limit Warning OlWaming
Download Pdf Manuals
Related Search
Related Contents
MANUAL DE INSTALACIÓN Wifi Action Camera T86 User Manual SMC Networks EZCONNECT SMCWUSB-N2 User's Manual User Manual Lenovo Miix 3 10 64GB Black プラレールチェーンSCシリーズ用取扱説明書 Installation and user manual Ecosun IRC Copyright © All rights reserved.
Failed to retrieve file