Home
EZiSYSTEM User Manual - M&P Survey Equipment Ltd
Contents
1. ft inch The service is too deep The signal received by the Locator is too small to register properly metres ft inch EZiSYSTEM How to Use the Locator 29 EZiISYSTEM How to Use the Locator 30 Information code Description Information on instru ment label The signal received by the Locator is too large to register properly Depth function not available The Locator is set to the wrong mode for a depth reading to be taken Current Measurement Current Measurement is used to identify the service to which the transmitter is attached i550xf i650xf and i750xf this is measured in milliamperes mA The transmitter is used to apply a signal current to the required service The signal can also couple to additional services making it hard to di
2. 2 7 Memory amp Communication Data Records The i600 i650 1700 1750 i600xf i650xf and i750xf locators record and store information whilst they are in use The locators start to record information every second after comple tion of the initial start up routine These records logs are stored in the locator s memory and can be retrieved and transferred via Bluetooth to a PC for analysis a The records are sequentially stored once the locator s memory is full the oldest records will be overwritten Yo A communication pack is available from an authorised supplier enabling users to retrieve the locators stored log files We recommend you to install and use the Bluetooth Adapter amp Logicat Software provided in the communication pack EZiSYSTEM How to Use the Locator 37 EZiISYSTEM How to Use the Locator 2 8 Data Records 38 Internal GPS The i700 1750 i750xf locators have an internal GPS module which is used to record the geographical position of use The geographical position Latitude and Longitude is stored in the log file and provides information on where the locator was used The M icon is used to display the GPS status as follows M flashing GPS fix available and the geographical position is being recorded to the loca tors log files M static No GPS fix and the geographical position is not being recorded to the locators log files GPS GPS S S GPS Search Mode i700
3. 3 Replace all batteries with six new LR6 AA type alkaline batteries or remove and recharge the battery pack if rechargeable batteries are fitted 2 4 Description Hazard zone status indicators Hazard Zone Provides an additional warning to the close proximity of buried services and functions in the following modes e Power e 8 kHz e 33 kHz e Auto mode Power mode only e 512 Hz amp 640 Hz xf models only Status indicator Description Hazard zone is switched on Hazard zone on and is alarming Hazard zone is switched off EZiSYSTEM How to Use the Locator EZiISYSTEM How to Use the Locator 20 L Caution The absence of a positive indication does not guarantee the non existence of a service Services without a detectable signal may be present The Locators can only locate non metallic services such as plastic pipes typically used by the water and gas utilities with the use of appropriate accessories Precautions Always excavate with care 2 5 How to Locate a Service Start up test The following test sequence will take place every time the Locator is activated On test Test pattern Info on label Audio Output On throughout test sequence Signal Strength indi Scrolls through in m cator sequence once 512r Mode indicators Briefly illuminated Indicator Icons Briefly illuminated Battery indicator On throughout test seq
4. Removal of hazard notices Opening the product using tools for example screwdriver unless this is specifically permitted for certain functions Modification or conversion of the product Use after misappropriation 65 EZiISYSTEM Safety Directions 66 N Warning 9 3 Environment Z Danger 9 4 Manufacturer of the product Manufacturers of non Cable Detection accesso ries e Use of products with obviously recognizable damages or defects e Use with accessories from other manufacturers without the prior explicit approval of Cable Detection e Inadequate safeguards at the surveying site for example when measuring on roads Adverse use can lead to injury malfunction and damage It is the task of the person respon sible for the equipment to inform the user about hazards and how to counteract them The product is not to be operated until the user has been instructed on how to work with it Limits of Use Suitable for use in an atmosphere appropriate for permanent human habitation not suit able for use in aggressive or explosive environments Local safety authorities and safety experts must be contacted before working in hazardous areas or in close proximity to electrical installations or similar situations by the person in charge of the product Responsibilities Cable Detection Ltd Staffordshire UK hereinafter referred to as Cable Detection is respon sible for supplying the product including t
5. Power mode to 3 m 10 ft Radio mode to 2 m 7 ft Transmitter mode Dependent on Transmitter and service type EZiCAT i550 i650 i750 EZICAT i550xf i650xf i750xf 10 of depth in line or Sonde 10 of depth in line or Sonde 0 3 to 3 0 m 1 to 10 ft Line Mode 0 3 to 3 0 m 1 to 10 ft Sonde Mode 0 3 to 3 0 m 1 to 10 ft Line Mode 0 3 to 9 99 m 1 to 32 ft 9 inches Sonde Mode Operating frequencies Bluetooth when fitted Memory capacity GPS Sensor i700 i750 i750xf EZiSYSTEM Technical Data Mode Frequency Power mode 50 Hz or 60 Hz Radio mode 15 kHz to 60 kHz 8 kHz mode 8 192 8 kHz 33 kHz mode 32 768 33 kHz Auto mode Power mode and Radio mode 512 Hz xf models 512 512 Hz 640 Hz xf models 640 640 Hz Class 2 nominal range 30 m i600 i650 i600xf i650xf 32 Mb 1700 1750 1750xf 64 Mb e Chipset MediaTek MT3329 WAAS EGNOS capable 1 e Type L1 frequency C A code SPS e Channels 22 tracking 66 search channels e Accuracy 2 Position 1 8m CEP95 Velocity 0 1m s Time 50ns RMS e Start time Cold 12 min max 34s typical Warm 34s typical Hot 1s typical 1 WAAS available in North America only EGNOS available in Europe only 2 Accuracy is dependent upon various factors including atmospheric conditions multipath obstructions signal geometry and number of tracked satellites 81 EZiSYSTEM Technical Data
6. Precautions Do not use on electrical services which have impaired or no insulation If in doubt do not use EZiSYSTEM Safety Directions 69 EZiISYSTEM Safety Directions 70 Z Danger When using a Property Connection Set a hazardous signal may be present on the service or mains outlet causing personal harm Precautions Do not use on electrical services which have impaired or no insulation If in doubt do not use Replace damaged Property Connection Set cable assembly before use Inadequate securing of the surveying site can lead to dangerous situations for example in traffic on building sites and at industrial installations Precautions Always ensure that the survey site is adequately secured Adhere to the regulations governing safety and accident prevention and road traffic The transmitter is capable of outputting potentially lethal voltages Precautions Care should be taken when handling exposed or non insulated connections including the connection cables sets the earth pin and the connection to the service Notify others who may be working on or around the service The transmitter is capable of outputting potentially lethal voltages Precautions Care should be taken when using the maximum power output level Risk of electric shock when removing the Transmitter s battery pack Precautions Before removing the battery pack switch the transmitter off and remove any cable set or accessories from the c
7. i750 amp i750xf A GPS search mode is activated as part of the start up test allowing the internal GPS module time to search for a GPS position GPS search mode is active following the start up test even if the locator is off the search mode will stop when a GPS position is obtained or a 12 minute search period has elapsed GPS search mode does not affect the locator s performance and the locator can be used as normal throughout this search mode ae When retrieving log files from the i700 i750 amp i750xf P C must be selected from the COM setting as described in section 2 3 Locator Setup and Information COM Setting Options PC Enables Bluetooth communication to Logicat Software BT1 Enables Bluetooth option 1 refer to section 2 6 BT2 Enables Bluetooth option 2 refer to section 2 6 GPS Switches GPS on following use with BT1 or BT2 settings ae BT1 and BT2 connections will be maintained for a three hour period when selected during this period the GPS will be off The GPS will automatically activate after the three hour period has elapsed or GPS is selected from the COM Setting EZiSYSTEM How to Use the Locator 39 EZiISYSTEM How to Use the Transmitter 40 3 How to Use the Transmitter 3 1 General information Tracing signal The Transmitter applies an electrical current signal onto a buried metallic service which enables the service to be traced and identified by the Locator operating in the same mode Opera
8. information to the data logger press the i Button whilst LOG is displayed e Whilst the Locator is calculating depth the data output stops e If there is no wireless communication then the LOG function will not be displayed and the unit will function as a Locator e The Locator will output ASCII text Refer to ASCII text description for more information ASCII text description ASCII output pattern e BT1 standard on all Bluetooth enabled locators DVxXxxSNxxxxxxSVxxxx IMxxxxxDTdd mm yyCMxxS TxBTxMDxSSxxUMxDPxxxx e BT2 model dependent DPxxxxUMxMDxSSxxDVxxxSNxxxxxxCMxxBTxS TxSVxxxxDTxXxxxxxxx TMXxxxx EZiSYSTEM How to Use the Locator 35 EZiISYSTEM How to Use the Locator 36 Data output Range Example value Description DV 000 to 999 550 Model identifier SN 000000 to 999999 123456 Serial number SV 0 00 to 9 99 3 01 Software version TM 00 00 to 23 59 08 30 Time hh mm default 00 00 no RTC fitted DT 00 00 00 to 31 12 99 01 12 10 Date dd mm yy default 00 00 00 no RTC fitted CM 00 to 15 12 Number of months until next calibration 00 to 15 ST Oor 1 Self test 0 Pass 1 Fail BT 0to9 Battery level 0 Empty 9 Good MD 0to6 Mode 0 Power 1 Radio 2 8 kHz 3 33 kHz 4 Auto 5 512 Hz 6 640 Hz SS 01 to 48 16 Signal strength 01 to 48 UM M or M Units of measurements M or I Metres or Imperial DP 0 30 to 3 00 or 125 Depth value displayed depends on value for UM
9. or off to suit light conditions Battery Indicator Indicates the battery condition Segment illumina tion decreases as battery condition declines Replace the batteries when the battery indicator is empty M Indicator Symbol Static Memory enabled GPS indicator i700 i750 i750xf Symbol Flashing GPS active and recording GPS coordinates Symbol Static No GPS position Indicates the Locator requires periodic service or unit is faulty i Numeric Signal Strength Indicator SSI Symbol Static SSI is enabled No Symbol SSI is disabled j Current Indicator i550xf i650xf and i750xf Indicates the amount current flowing through a service which is applied by the Transmitter This is measured in milliamperes mA k Measurement Unit Depth indication with the i550 i650 i550xf i650xf and i750xf Indicates depth indication is in metric or feet and inches I Display Readout Alpha numeric matrix indicates system set up and depth indication m Depth Mode Indicators Indicates a depth reading to a service or a Sonde Depth locators only Service depth icon used to indicate Hazard Zone status n i Button Used to access the user settings and to provide a depth readout for Depth locators EZiSYSTEM How to Use the Locator 15 EZiISYSTEM How to Use the Locator 2 3 Locator settings 16 Locator Setup and Information The i Series Locators offer a range of settings which the operator can adjust to their own prefe
10. 0 0en Original text S 2013 Cable Detection Ltd Staffordshire UK detection delivering expert technology
11. 220 V 50 Hz 220 V 50 Hz Asia Abu Dhabi Afghanistan Armenia Azerbaijan Bahrain Bangladesh Brunel Cambodia China Cyprus Georgia Hong Kong India Indonesia lran lraq Israel Japan Jordan Kazakhstan Kirgizstan Korea North Korea South Kuwait Laos Lebanon Malaysia Myanmar 230 V 50 Hz 220 V 50 Hz 220 V 50 Hz 220 V 50 Hz 110 230 V 50 Hz 60 Hz 230 V 50 Hz 240 V 50 Hz 220 V 50 Hz 220 V 50 Hz 240 V 50 Hz 220 V 50 Hz 220 V 50 Hz 230 250 V 50 Hz 60 Hz 127 220 V 50 Hz 220 V 50 Hz 220 V 50 Hz 230 V 50 Hz 100 220 V 50 Hz 60 Hz 220 V 50 Hz 220 V 50 Hz 220 V 50 Hz 220 V 50 Hz 110 220 V 60 Hz 240 V 50 Hz 220 V 50 Hz 110 220 V 50 Hz 240 V 50 Hz 240 V 50 Hz EZiSYSTEM World Frequency Zones Oman Pakistan Philippines Qatar Saudi Arabia Singapore Sri Lanka Syria Taiwan Tajikistan Thailand Turkey Turkmenistan United Arab Emirates Uzbekistan Vietnam Yemen 240 V 50 Hz 230 V 50 Hz 110 220 V 60 Hz 240 V 50 Hz 127 220 V 50 Hz 230 V 50 Hz 230 V 50 Hz 220 V 50 Hz 110 220 V 60 Hz 220 V 50 Hz 220 V 50 Hz 220 V 50 Hz 220 V 50 Hz 220 V 50 Hz 220 V 50 Hz 120 220 V 50 Hz 220 V 50 Hz 115 EZiSYSTEM Index 116 Index C ODETA serea AA 94 Conductive Rod ONIO r E E E E E EAE 94 Functional CHECK ccccccssssssscccceseseeeeeeeeeeeeseeeeeaeaeeeees 107 Sonde Gjo e e E
12. B digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a partic ular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and the receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help Changes or modifications not expressly approved by Cable Detection for compliance could void the user s authority to operate the equipment EZiSYSTEM Safety Directions 75 EZiISYSTEM Safety Directions Labelling Locator 8kHz and 33kHz 76 Labelling Transmitter EZiSYSTEM Safety Directions Power 3 l Cable Detection Ltd ee fe C pi Stoke On Trent ova ax Staffordshire NiMH 4 8V 9000mA Type Art No Ser
13. Brazil 110 127 220 V 60 Hz Chile 220 V 50 Hz Central America Colombia 110 220 V 60 Hz Bahamas 115 V 60 Hz Ecuador 110 220 V 60 Hz Barbados 115 V 50 Hz French Guiana 220 V 50 Hz Belize 110 220 V 60 Hz Guyana 110 240 V 60 Hz Bermuda 115 V 60 Hz Paraguay 220 V 60 Hz Costa Rica 120 V 60 Hz Peru 220 V 60 Hz Cuba 115 120 V 60 Hz Surinam 110 127 V 60 Hz Dominican Republic 110 220 V 60 Hz Uruguay 220 V 50 Hz El Salvador 120 240 V 60 Hz Venezuela 120 240 V 60 Hz Guatemala 115 230 V 60 Hz Haiti 110 220 V 60 Hz Australia Oceania Honduras 110 220 V 60 Hz Australia 240 V 50 Hz Jamaica 220 V 50 Hz Fiji Islands 240 V 50 Hz Netherland Antilles 110 127 V 50 Hz New Zealand 230 V 50 Hz Nicaragua 120 V 60 Hz Solomon Island 240 V 50 Hz Panama 120 V 60 Hz Tonga 230 V 50 Hz Puerto Rico 120 V 60 Hz Trinidad amp Tobago 115 230 V 60 Hz Virgin Islands 120 V 60 Hz Europe Albania Austria Belgium Belarus Bulgaria Croatia Czech Republic Denmark Estonia Finland France Germany Greece Hungary Iceland lreland Italy Latvia Lithuania Luxemburg Moldavia Netherlands Norway Poland Portugal Romania Russia Slovakia EZiSYSTEM World Frequency Zones 230 V 50 Hz 230 V 50 Hz 230 V 50 Hz 230 V 50 Hz 230 V 50 Hz 230 V 50 Hz 230 V 50 Hz 230 V 50 Hz 230 V 50 Hz 230 V 50 Hz 230 V 50 Hz 230 V 50 Hz 230 V 50 Hz 230 V 50 Hz 230 V 50 Hz 230 V 50 Hz 230 V
14. Display panel Keypad Speakers 82 48 segment bar graph 5 mode indicators Standard 7 mode indicators xf models Battery status indicator Line depth indicator Sonde depth indicator Bluetooth indicator where fitted Integrated backlight Annual service indicator 3 alpha numeric dot matrix displays 5x7 Signal Strength Indicator mA milliamperes Memory amp GPS 2 membrane push buttons Dual speakers Audio volumes 85 dBA 30 cm Tone Power Radio and Auto mode Continuous tone different pitch for each mode 8 kHz and 33 kHz mode Pulsed tone different pitch for each mode 512 Hz and 640 Hz mode Pulsed tone different pitch for each mode All tones are different Pneumatic headphone sockets are integrated Internal battery Instrument dimensions Weight EZiSYSTEM Technical Data Type 6 x LR6 AA alkaline Typical operating time 40 hrs intermittent use at 20 C 68 F in 8 kHz mode or 33 kHz mode 760 mm 30 Inches 250 mm 10 Inches Instrument 2 7 kg 6 Ibs including batteries 83 EZiSYSTEM Technical Data 84 Environmental specifica Type Description tions Temperature Operating 20 C to 50 C 4 F to 122 F Storage 40 C to 70 C 40 F to 158 F Protection against Water Dust IP54 IEC 60529 Dust protected Humidity 95 RH non condensing The effects of condensation are to be effectively counteracted by periodically drying
15. EZiISYSTEM How to Use the Locator 28 Se e Activating line depth will provide an inaccurate readout e Mark utilities with marker paint pegs flags or similar Never drive pegs into the ground over the service e Additional services may be within the excavation zone as well as the service you are taking a depth reading from e An additional depth reading should be taken with the locator lifted off the ground by approximately 100 mm 4 inches The reading obtained should confirm the addition of this height Depth shown and diameter Take special care when the signal is produced by a sonde lying in a large diameter conduit The depth reading may not indicate the real depth of the service especially if the sonde is lying at the base of a large diameter duct Precautions Always compensate depth reading for service size Depth code information Information code Description Information on instru ment label metres ft inch The service is too shallow to register prop erly metres ft inch metres
16. No This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Made in the UK 77 EZiISYSTEM Safety Directions Conductive Rod Se is a SS ISN l ji J K Md A J pZ a b c 78 End of Coil Sonde mode Used to accurately pinpoint the end point of the rod Rod Line mode Flexible Glass Fibre sheathed which incorporates copper wires to conduct the signal Connection Terminals Used to connect to the Transmitter Frame Houses the flexible rod Can be used in both vertical shown and horizontal orientation Signal Clamp b a d d f Property Connection Set aa iN Lee S EZiSYSTEM Safety Directions e f Transmitter plug connector Jaws Handle Cable Mains plug connector In line isolator Transmitter plug connector 79 EZiSYSTEM Technical Data 10 10 1 Typical detection range Operating depth range Typical depth accuracy Technical Data Locator i Series Technical Data Mode Power mode Radio mode 80 Distance along conductor length of conductor length of conductor Conductive Rod mode length of unwound rod Mode Range
17. out the product Conformity to national e FCC Part 15 applicable in US regulations e Hereby Cable Detection Ltd declares that the EZiICAT 1500 1550 1600 1650 1700 1750 i500xf i550xf i600xf i650xf 1700xt i750xf is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC The declaration of conformity may be consulted at http www cabledetection co uk ce Class 1 equipment according European Directive 1999 5 EC R amp TTE can be C 4 placed on the market and be put into service without restrictions in any EEA member state e The conformity for countries with other national regulations not covered by the FCC part 15 or European directive 1999 5 EC has to be approved prior to use and opera tion Frequency band 50 Hz to 60 kHz Output power Receive only 10 2 Typical detection range Operating transmission frequencies Display panel Keypad EZiSYSTEM Technical Data Transmitter Technical Data 1 Watt models Mode Output Induction mode Connection mode t100 amp t100xf Connection mode t300 amp t300xf e 8 192 8 kHz or e 32 768 33 kHz e 512 512 Hz xf models e 640 640 Hz xf models e 2 LED Mode Indicators e 2 LED Frequency Indicators Standard e 4 LED Frequency Indicators xf models e LED Battery Status Indicator e 3 LED Power Output Indicators 4 membrane push buttons Up to 1 W max Up to 1 W max when connecte
18. pack if rechargeable batteries are fitted EZiISYSTEM How to Use the Transmitter SA 1 Unscrew the two fasteners and remove 2 Replace all batteries with four new LR20 43 EZiISYSTEM How to Use the Transmitter 44 Risk of electric shock when removing the Transmitter s battery pack Precautions Before removing the battery pack switch the transmitter off and remove any cable set or accessories from the connection socket The Transmitter s battery pack may get hot after prolonged use Precautions Allow the battery pack to cool down before removing 3 3 How to Locate a Service Using the Transmitter Start up test The following test sequence will take place every time the Transmitter is activated On test Audio output Test pattern On throughout test sequence LEDs LEDs are all lit throughout the test sequence Default mode selection 33 kHz and power output level two is automatically selected Induction mode is selected unless the Trans mitter s cable set or accessories are connected EZiISYSTEM How to Use the Transmitter 45 EZiISYSTEM How to Use the Transmitter 46 Using the Transmitter in Induction mode NO of Switch the Transmitter on observe the Induction mode LED is illuminated and the battery level is adequate Change batteries when indicated Select the required power output level and frequency output Place the Transmitter o
19. status of the unit its batteries and basic functionality The following list is used to achieve this 1 Inspection e Casing The casing should be free of significant damage e Labels Body labels must be legible and intact Display label must be free of damage and tears e Battery hatch The hatch must lock into place e Battery holder All the battery contacts and springs on the holder must be free of corrosion and the holder in good condition e Battery contacts The battery contacts must be free of corrosion Once the general condition of the Locator is established the Audio Visual test can be performed 2 Audio Visual display test Upon depressing the trigger the Locator should test the display and speakers by illumi nating each segment in the bar display the mode and function indicators and depth display the battery indicator light will illuminate throughout the display test All LCDs must be operative and an audible output must be heard EZiSYSTEM Functional Checks 97 EZiISYSTEM Functional Checks 98 Checking the performance Checking depth indica tion i550 i650 1750 i550xf i650xf i750xf 3 Battery Functional self check If there is no response when the trigger is activated or the low battery illuminates or flashes after the Audio Visual display test the batteries will have to be replaced Use alka line batteries Replace all of the batteries at the same time The purpose of the following proced
20. 50 Hz 230 V 50 Hz 230 V 50 Hz 230 V 50 Hz 230 V 50 Hz 230 V 50 Hz 230 V 50 Hz 230 V 50 Hz 230 V 50 Hz 230 V 50 Hz 230 V 50 Hz 230 V 50 Hz Slovenia Spain Sweden Switzerland Ukraine United Kingdom Yugoslawia 230 V 50 Hz 230 V 50 Hz 230 V 50 Hz 230 V 50 Hz 230 V 50 Hz 230 V 50 Hz 230 V 50 Hz 113 EZiSYSTEM World Frequency Zones Africa Algeria Angola Benin Botswana Burkina Faso Burundi Cameroon Central Africa Rep Chad Congo Dahomey Egypt Ethiopia Gabon Gambia Ghana Ivory Coast Kenya Lesotho Liberia Libya Malawi Mali Mauritania Mauritius Morocco Mozambique Namibia 127 220 V 50 Hz 220 V 50 Hz 220 V 50 Hz 220 V 50 Hz 220 V 50 Hz 220 V 50 Hz 127 220 V 50 Hz 220 V 50 Hz 220 V 50 Hz 220 V 50 Hz 220 V 50 Hz 220 V 50 Hz 220 V 50 Hz 220 V 50 Hz 230 V 50 Hz 240 V 50 Hz 220 V 50 Hz 240 V 50 Hz 220 240 V 50 Hz 120 V 60 Hz 115 220 V 50 Hz 230 V 50 Hz 220 V 50 Hz 220 V 50 Hz 230 V 50 Hz 127 220 V 50 Hz 220 V 50 Hz 220 V 50 Hz Niger Nigeria Rwanda Senegal Sierra Leone Somalia South Africa Sudan Swaziland Tanzania Togo Tunisia Uganda Zaire Zambia Zimbabwe 114 220 V 50 Hz 230 V 50 Hz 220 V 50 Hz 110 V 50 Hz 230 V 50 Hz 220 V 50 Hz 220 240 V 50 Hz 240 V 50 Hz 220 V 50 Hz 230 V 50 Hz 127 220 V 50 Hz 127 220 V 50 Hz 240 V 50 Hz 220 V 50 Hz
21. BT1 Enables Bluetooth option 1 refer to section 2 6 BT2 Enables Bluetooth option 2 refer to section 2 6 GPS Switches GPS on following use with BT1 or BT2 settings Sets the Locators start up mode On The Locator starts in the last mode of operation used Off The Locator starts in Power mode 1 Switch the Locator on NO Ensure the Locator is in Power mode If required press Function Button to select mode NO O01 B OW EZiSYSTEM How to Use the Locator Depress the i Button until the user settings are displayed in the display readout Press Function Button to toggle through to desired setting Press Button to select the setting Press Function Button to activate adjust Press Button to store and exit 17 EZiISYSTEM How to Use the Locator 18 Z Danger Changing the battery The Locator may fail to detect electrical services in Power mode if an incorrect power setting is used Precautions Before use verify the Locator is setup to be compatible with mains frequency supply in your country Options are 50 or 60 Hz Refer to Appendix B World Frequency Zones for more information Contact your agency or Cable Detection authorised service workshop if your unit is incor rectly configured for your region 1 Replace or Recharge the batteries when the battery status indicator is empty 2 Press the release button to unlock the Battery Hatch Remove the battery holder from the Locator
22. E E E E 91 L SLOLAJG penisimani inoi TAn a 91 Locator Transmitter Functional CROCK sirimiri echo aeecehancen 97 Operating cecececcesececeecececescececeseececececerserscersarenersates 87 O SOLIE pien 87 Transmitter PETANG AEREN ANGE seers ecacan cece taaamanseaasaesasae a Functional Check sssssssssssssesrnssrnnnnnnnnnnnnrnnnnrnnrnnnrnnnne 101 S Typical depth accuracy cccsccsecseeceesseeceeeeeseeeeeeeeeeeeeaess 80 Sonde Typical detection range Functional Check cccccccceeeceeeseeeeeeseeeeeeeseeeeeeeenaees 109 Distance along CONUUCTOF sierprisreyinananieniiineiiies 80 T MC TIN NCG ID Ale een E 80 Temperature Conductive Rod OPET eeercereercr rere termes tre Crier ere ree terre errr 89 O Co ea E E E 89 Locator OD CR QUIS E E E E E 84 AOLO o E E E EE 84 Property Connection Set ODEN EE E a oemseniaoeacssciatens 92 SOAGE aincitnsisastinnaveiateractioninetiienimnidarsianiena 92 Signal Clamp EZiSYSTEM Index 117 Total Quality Management Our commitment to total customer satisfaction TOM ISO 9001 Cable Detection Ltd Staffordshire UK has been certified as being equipped with a quality system which meets the International Standards of Quality Management and Quality Systems ISO standard 9001 Ask your local Cable Detection dealer for more information about our TOM program Cable Detection Ltd 1 Blythe Park Cresswell Stoke On Trent Staffordshire ST11 9RD UK www cabledetection co uk 124701 1
23. EZiISYSTEM How to Use the Transmitter 47 EZiISYSTEM How to Use the Transmitter 48 Z Danger Connecting the cable set to a live service can result in an electric shock Precautions The connection cable set should never be connected directly to a live service The transmitter is capable of outputting potentially lethal voltages Precautions Care should be taken when handling exposed or non insulated connections including the connection cables sets the Earth Pin and the connection to the service Notify others who may be working on or around the service The transmitter is capable of outputting potentially lethal voltages Precautions Care should be taken when using the maximum power output level e Ensure there are no services below the ground when using the Earth Pin Use the Locator in advance e The black cable can be connected to other metallic structures which go into the ground e Indry conditions it may be necessary to add water around the earth point to get a good connection e Examine connection points and remove contamination if a continuous audible output is not achieved e An extension cable is available to extend the red or black cable sets 4 How to Use the Conductive Rod 4 1 General Information Description The Conductive Rod is a service tracer enabling small diameter non conductive pipes or ducts to be traced It can be used in Line mode or Sonde mode 4 2 Conductive Rod Overview Conductive
24. Radio e Active modes 8 kHz 33 kHz additionally 512 Hz and 640 Hz on xf models e Auto mode Combined Power and Radio modes An electromagnetic signal radiates from buried conductive services as an electrical current flows through them The Locator processes these signals and displays their presence Some signals are already present on buried services and can be readily detected by the Locator We call these passive signals These signals are generated by power distribution systems and radio transmitters Some conductive services do not emit passive signals These services may be traced by applying a signal to the service by using a transmitter Depth indication is only available with the i550 i650 1750 i550xf i650xf i750xf locators when used in conjunction with the Transmitter or Sonde The displayed depth is to the centre of the service or to the Sonde Current measurement is only available on the i550xf i650xf or i750xf when used in conjunction with the transmitter The highest current reading mA will be displayed over the service which has the transmitter connected to it Data can be wirelessly transferred from the Bluetooth enabled Locator to devices which are designed to accept the information EZiSYSTEM How to Use the Locator 11 EZiISYSTEM How to Use the Locator 12 Hazard zone Provides an additional alarm indicating the close proximity of a service emitting a Power 8 kHz 33 kHz 512 Hz and 640 Hz on xf
25. Rod main parts NS j ip 7 NZ Ve yx S a b c d End of Coil Sonde mode Used to accurately pinpoint the end point of the rod Rod Line mode Flexible Glass Fibre sheathed which incorporates copper wires to conduct the signal Connection Terminals Used to connect to the Transmitter Frame Houses the flexible rod Can be used in both vertical shown and horizontal orientation EZiSYSTEM How to Use the Conductive Rod 49 EZiISYSTEM How to Use the Conductive Rod 50 4 3 How to Locate a Service Using the Conductive Rod Using the Conductive Rod in Line mode 1 Insert the rod into the pipe duct conduit or drain until the desired length is in place Plug the Transmitter s cable set into the connection socket Connect the black cable to the Earth Pin ensuring that no services are below push the Earth Pin into the ground Connect the red cable to the positive terminal on the conductive rod Switch the Transmitter on observe the Connection mode LED is illuminated and the battery level is adequate Change batteries when indicated Select the required power output level and frequency output A good level of tracing signal is indicated when the power output LED amp audible tone changes from pulsed to continuous Trace the length
26. The reading obtained should confirm the addition of this height EZiSYSTEM How to Use the Locator 25 EZiISYSTEM How to Use the Locator Depth shown and actual depth 26 d1 Depth shown on the EZICAT depth to the centre of the line d2 Actual depth of the service Note the difference between d1 and d2 Z Warning The depth reading might not reflect the real depth if your Locator picks up the signal induced into the service by the Transmitter This signal is radiated from the centre of the service This is even more important when the signal is produced by a Sonde lying in a large diam eter conduit Precautions Always compensate depth reading for service size Measuring Sonde depth 1 Switch on the sonde and set to 1550 i650 i750 i550xf the required frequency Refer i650xf and i750xf to 7 Howto Use the Sonde for more information 2 Select the mode to suit the Sonde s output Position the Locator directly over and in line with the Sonde Refer to 7 How to Use the Sonde for more informa tion 3 Press and hold down the i Button for 2 seconds until the dashed lines have scrolled through once 4 The display readout will indi cate the depth of the Sonde and the Sonde mode icon will be displayed H EZiSYSTEM How to Use the Locator 27
27. Transport 63 8 2 Storage 63 8 3 Cleaning and Drying 64 9 Safety Directions 65 9 1 General Introduction 65 9 2 Intended Use 65 9 3 Limits of Use 66 9 4 Responsibilities 66 9 5 Hazards of Use 67 9 6 Electromagnetic Compatibility EMC 72 9 7 FCC Statement Applicable in U S 75 EZiSYSTEM Table of Contents 5 EZiISYSTEM Table of Contents 6 10 Technical Data 80 10 1 Locator i Series Technical Data 80 10 2 Transmitter Technical Data 1 Watt models 85 10 3 Conductive Rod Technical Data 88 10 4 Sonde Technical Data 90 10 5 Property Connection Set Technical Data 92 10 6 Signal Clamp Technical Data 94 11 International Limited Warranty 96 Appendix A Functional Checks 97 A 1 Locator Functional Check 97 A 2 Transmitter Functional Check 101 A 3 Conductive Rod Functional Check 107 A 4 Sonde Functional Check 109 Appendix B World Frequency Zones 112 Index 116 1 1 er Naming convention Index Instrument label EZiISYSTEM General Information General Information How to Use this Manual It is recommended to set up the product while reading through this manual EZICAT i500 i550 i600 i650 i700 i750 and xf models are hereinafter referred to as Locator Differences between the models are marked and described EZiTEX t100 t300 and xf models is hereinafter referred to as Transmitter EZiROD is hereinafter referred to as Conductive Rod The index is at the back of the manual On the Loca
28. and Dust protected Sand Rod Fully submersible Humidity 95 RH non condensing The effects of condensation are to be effectively counteracted by periodically drying out the product e Hereby Cable Detection Ltd declares that the Conductive Rod is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC The declaration of conformity may be consulted at http www cabledetection co uk ce Class 1 equipment according European Directive 1999 5 EC R amp TTE can be C 4 placed on the market and be put into service without restrictions in any EEA member state e The conformity for countries with other national regulations not covered by the FCC part 15 or European directive 1999 5 EC has to be approved prior to use and opera tion 89 EZiSYSTEM Technical Data 10 4 Sonde Technical Data Operating transmission e 8 192 8 kHz or frequencies e 32 768 33 kHz Internal battery Type 1 x LR6 AA alkaline Typical operating time 40 hrs intermittent use at 20 C 68 F in 8 kHz mode or 33 kHz mode Instrument dimensions 38 mm 1 5 Inches 120 mm 4 7 Inches Weight Instrument 0 18 kg 0 4 Ibs including batteries elas specifica Type Description ions Temperature Operating 20 C to 50 C 4 F to 122 F Storage 40 C to 70 C 40 F to 158 F Protection against Water Dust Fully submersible and Sand Humidity 95 RH non condensing The effe
29. be adjusted between 0 to 5 seconds 7 1 Position the Locator directly 9 over the service S IIN 7 2 Rotate the Locator on its axis 3 3 The blade of the Locator will be 9 in line with the service when the signal strength indicator is at its minimum Depth Indication 1 Apply a signal to the service 1550 i650 i750 i550xf Refer to 3 How to Use the i650xf and i750xf Transmitter for more informa tion 2 Select the mode to suit the Transmitter s output Position the Locator directly over and at 90 degrees to the direction of the service 3 Press and release the i Button 4 The display readout will indi cate the depth of the service and the Line mode icon will be displayed ES e Activating Sonde depth will provide an inaccurate readout e Mark utilities with marker paint pegs flags or similar Never drive pegs into the ground over the service e Additional services may be within the excavation zone as well as the service you are taking a depth reading from e The reading will be more accurate when taken over a straight run where the service does not bend or have a service crossing it or coming off it e An additional depth reading should be taken with the locator lifted off the ground by approximately 100 mm 4 inches
30. ble output must be heard Batteries Replace Replace alkaline batteries if exhausted no response or if the battery indicator light Is illuminated or flashing after display test Replace all batteries EZiSYSTEM Functional Checks 105 EZiISYSTEM Functional Checks 106 Functional Test Check List 7 Induction mode Return for repair Replace Reduced or no output signal 8 Connection mode no change in audio indica tion 9 Connection mode no change in audio indica tion Tested by Return for repair Replace Return for repair Replace Faulty cable No output signal Date A 3 Checking the function Conductive Rod Functional Check The purpose of the following procedure is to verify the performance of the Conductive Rod To carry out this test the following are required e A Transmitter for generating the signal in the Sonde and Line mode tests e The cable set for the Conductive Rod Plug the Transmitter s cable set into the connection socket Connect the red cable to the positive terminal on the conductive rod connect the black cable to the negative terminal Switch the Transmitter on and adjust the power output on the Transmitter to minimum the audible output must be constant Disconnect the black cable from the negative terminal the audible output must be pulsed If any of these tests give no response or a significan
31. ction range will indicate poor battery condition Use alkaline batteries EZiSYSTEM Functional Checks 109 EZiISYSTEM Functional Checks 110 1 Switch sonde on and activate 33kHz mode 2 Set Locator to 33 kHz mode and aim at Sonde see diagram 3 At 2 m 6 56 ft the Locator must be at maximum 4 Repeat this with Sonde and Locator in 8 kHz amass ft J 7 5 m 16 4 ft 5 m 16 4 ft af S If any of these tests give no response or a significantly different response from normal the Sonde should be returned for service Functional test check list Functional Test Check List Unit Serial Number Comments Sonde Test Operative Fail analysis Notes Yes No N A 1 Casing Fail Casing should be free of damage 2 Screw thread and Fail Screw thread must be intact 5 8 kHz mode Tested by seal and seal in place 3 Battery contacts Fail Contacts must be free of corro sion 4 33 kHz mode Fail LED must be illuminated brightly and pulse fast Locator must provide maximum display at 2 metres Fail LED must be illuminated brightly and pulse slowly Locator must provide maximum display at 2 metres Date EZiSYSTEM Functional Checks 111 EZiISYSTEM World Frequency Zones 112 Appendix B World Frequency Zones North America South America Canada 120 V 60 Hz Argentina 230 V 50 Hz United States 120 V 60 Hz Bolivia 110 V 50 Hz Mexico 120 V 50 Hz 60 Hz
32. cts of condensation are to be effectively counteracted by periodically drying out the product Conformity to national e Hereby Cable Detection Ltd declares that the Sonde is in compliance with the essen regulations tial requirements and other relevant provisions of Directive 1999 5 EC The declara tion of conformity may be consulted at http www cabledetection co uk ce Class 1 equipment according European Directive 1999 5 EC R amp TTE can be C placed on the market and be put into service without restrictions in any EEA member state e The conformity for countries with other national regulations not covered by the FCC part 15 or European directive 1999 5 EC has to be approved prior to use and opera tion EZiSYSTEM Technical Data 91 EZiSYSTEM Technical Data 92 10 5 Property Connection Set Technical Data Operating transmission e 32 768 33 kHz frequencies Instrument dimensions 80 mm 3 1 Inches aC Da 100 mm 3 9 Inches Weight Instrument 0 15 kg 0 3 Ibs Environmental ficati Type Description specifications i Temperature Operating 20 C to 50 C 4 F to 122 F Storage 40 C to 70 C 40 F to 158 F Protection against Water Dust IP54 IEC 60529 and Sand Dust protected Type Description Humidity 95 RH non condensing The effects of condensation are to be effectively counteracted by periodically drying out the product Conformity to national e He
33. d to a buried service with an impedance of 100 Q Up to 3 W max when connected to a buried service with an impedance of 100 Q 85 EZiSYSTEM Technical Data Integral Speakers Internal battery Instrument dimensions Weight Audio Volumes Tone Type Typical operating time t100 amp t100xtf Typical operating time t300 amp t300xt 105 mm 4 13 inches 190 mm 7 48 inches 86 85 dBA 30 cm 8 kHz mode Low pitched tone 33 kHz mode Higher pitched tone 512 Hz mode xf models Low pitched tone 640 Hz mode xf models Low pitched tone Induction mode Pulsed tone Connection mode Pulsed tone when poor or no current output continuous tone when good connection 4 x D alkaline IEC LR20 supplied 30 hrs intermittent use at 20 C 68 F 15 hrs intermittent use at 20 C 68 F 235 mm 9 25 inches Instrument including batteries 2 4 kg 5 3 Ibs a naa specifica Type Description ions Temperature Operating 20 C to 50 C 4 F to 122 F Storage 40 C to 70 C 40 F to 158 F Protection against With cover open IP54 IEC 60529 Water Dust and Dust protected Sand With cover closed IP65 IEC 60529 and secured Dust tight Low power water jets Humidity 95 RH non condensing The effects of condensation are to be effectively counteracted by periodically drying out the product Conformity to national e FCC Part 15 applicable in US regula
34. eries locators the t Series transmitters and accessories Differences between the various instruments and models are marked and described EZiSYSTEM Introduction EZiSYSTEM Table of Contents 4 Table of Contents In this manual Chapter Page 1 General Information 7 1 1 How to Use this Manual 7 1 2 i Series General Information 8 1 3 i Series Instruments and Accessories 10 2 How to Use the Locator 11 2 1 General Information 11 2 2 Locator Overview 13 2 3 Locator Setup and Information 16 2 4 Hazard Zone 19 2 5 How to Locate a Service 21 2 6 Wireless Data Communication where applicable 34 2 7 Memory amp Communication 37 2 8 Internal GPS 38 3 How to Use the Transmitter 40 3 1 General information 40 3 2 Transmitter Overview 42 3 3 How to Locate a Service Using the Transmitter 45 4 How to Use the Conductive Rod 49 4 1 General Information 49 4 2 Conductive Rod Overview 49 4 3 How to Locate a Service Using the Conductive Rod 50 5 How to Use the Signal Clamp 52 5 1 General Information 52 5 2 Signal Clamp Overview 52 5 3 How to Locate a Service Using the Signal Clamp 53 6 How to Use the Property Connection Set 55 6 1 General Information 55 6 2 Property Connection Set Overview 55 6 3 How to Locate a Service Using the Property Connection Set 56 7 How to Use the Sonde 58 7 1 General Information 58 7 2 Sonde Overview 58 7 3 How to Locate a Service Using the Sonde 61 8 Care and Transport 63 8 1
35. g connector b Jaws a t c Handle d Cable 5 3 How to Locate a Service Using the Signal Clamp Using the Signal Clamp 1 Connect the Signal Clamp to the Transmitter 2 Open the jaws of the Signal Clamp and place around the service to be traced 3 Switch the Transmitter on and select the required power output level set the frequency output to correspond with the clamp A good level of tracing signal is indicated when the audible tone and power output LED are continuous 4 Trace the length of the service using the Locator set to the same frequency ES e Ensure the clamp jaws are fully engaged e Ensure the Transmitter s frequency output is comparable to that of the Signal Clamp Check the signal clamps type plate for the frequency rating Z Danger A hazardous signal may be present on the connection plug of the Signal Clamp when clipped over a live service Precautions The clamp should be connected to the Transmitter before clamping around a live service EZiSYSTEM How to Use the Signal Clamp 53 EZiSYSTEM How to Use the Signal Clamp Z Danger A hazardous signal may be present on the service causing personal harm Precautions use 54 Do not use on electrical services which have impaired or no insulation If in doubt do not 6 How to Use the Property Connection Set 6 1 General Information Description The Property Connection Set provides a safe technique of applying a traceable signal to li
36. he correct functioning of other products may be impaired Precautions While the product is in use connecting cables for example product to external battery product to computer must be connected at both ends EZiSYSTEM Safety Directions 73 EZiISYSTEM Safety Directions 74 N Warning Electromagnetic fields can cause disturbances in other equipment in installations in medical devices for example pacemakers or hearing aids and in aircraft It can also affect humans and animals Precautions Although the product meets in combination with radio or digital cellular phone devices recommended by Cable Detection the strict regulations and standards which are in force in this respect Cable Detection cannot completely exclude the possibility that other equip ment may be disturbed or that humans or animals may be affected e Do not operate the product with radio or digital cellular phone devices in the vicinity of filling stations or chemical installations or in other areas where an explosion hazard exists e Do not operate the product with radio or digital cellular phone devices near to medical equipment e Do not operate the product with radio or digital cellular phone devices in aircraft e Do not operate the product with radio or digital cellular phone devices for long periods with it immediately next to your body FCC Statement Applicable in U S This equipment has been tested and found to comply with the limits for a Class
37. he user manual and original accessories in a completely safe condition The manufacturers of non Cable Detection accessories for the product are responsible for developing implementing and communicating safety concepts for their products and are also responsible for the effectiveness of those safety concepts in combination with the Cable Detection product Person in charge of the product The person in charge of the product has the following duties e To understand the safety instructions on the product and the instructions in the user manual e To ensure that it is used in accordance with the instructions e To be familiar with local regulations relating to safety and accident prevention e To inform Cable Detection immediately if the product and the application becomes unsafe The person responsible for the product must ensure that it is used in accordance with the instructions This person is also accountable for the training and the deployment of personnel who use the product and for the safety of the equipment in use Hazards of Use The absence of instruction or the inadequate imparting of instruction can lead to incorrect or adverse use and can give rise to accidents with far reaching human material financial and environmental consequences Precautions All users must follow the safety directions given by the manufacturer and the directions of the person responsible for the product Watch out for erroneous
38. ial Number Yes Operative Functional Test Check List Comments Fail analysis No N A Notes 1 Casing Return for repair Replace Casing should be free of damage 2 Labels 3 Battery hatch 4 Battery holder 5 Battery contacts 6 Audio Visual display test EZiSYSTEM Functional Checks Return for repair Replace Return for repair Replace Replace Return for repair Return for repair Body labels must be legible and intact Display label must be free of damage and tears Hatches must be free of corrosion Holder must be free of corro sion Contacts must be free of corrosion LCD is illuminated and an audible output must be heard 99 EZiISYSTEM Functional Checks 100 Functional Test Check List 10 11 12 Batteries Power mode Radio mode 8 kHz 33 kHz Depth Mode Depth Locator only e 8 kHz 33 kHz e 512 Hz 640Hz xf models Replace Return for repair Return for repair Return for repair Return for repair Return for repair Replace alkaline batteries if pack is exhausted no response or if the battery indicator light is illuminated or flashing after display test Replace all batteries Response width and peak value similar to test unit Response width and peak value similar to test unit Response width and peak value similar to test unit Response width and peak
39. icator flashes to indicate a poor battery condition Replace all batteries with four new LR20 D type alkaline batteries or remove and recharge the battery pack if rechargeable batteries are fitted Checking the The purpose of the following procedure is to verify the performance of the Transmitter It is performance important that the test is conducted away from areas of electromagnetic interference 1 2 3 EZiSYSTEM Functional Checks Plug the Transmitter s cable set into the connection socket Connect the black and red cable clips together ensuring good metal to metal contact Hold down Frequency Control Button and switch the Transmitter on Note Hold the frequency control button down until the Extended Self Test has commenced Observe the displayed output Induction Mode Test Mode Display Induction LED illuminated Frequency Display Frequency LED illuminates showing the frequency on test Mode Display Induction LED off Connection Mode Test Mode Display Connection LED illuminated Frequency Display Frequency LED s illuminates showing the frequency on test Mode Display Connection LED off The transmitter will display the outcome Pass Battery indicator LED Flash if tested with poor batteries Audible Output High Low pulsed tone emitted three times Fail Battery indicator LED Flash if tested with poor batteries Audible Output Low pitch tone emitted Mode Display Induction or Connection LED illu
40. ignal strength indicator will rise and fall as you pass over it 3 Repeat the Sweep Search process in Radio mode KE The Sweep Search must be conducted in Power and Radio modes as a minimum as not all services including some electrical ones emit a power signal These services may be found using Radio mode or active modes c Hazard zone can be operated in Power 8 kHz 33 kHz and Auto 512 Hz and 640 Hz on xf models modes and provides an additional alarm to the presence of buried services which may be within close proximity ZNN XT nu aes y The service is directly below the Locator when the signal strength indicator is at its maximum The strength indicator drops to Its audio output will automatically j minimum position ion Pinpointing the service Retrace your steps to the area adjust to facilitate pinpointing over the service and automati me e Mark services with marker paint pegs flags or similar Never drive pegs into the ground over the service Sy 9 9 DS where the highest signal reading peak response was obtained cally reset when the signal e The signal strength indicator does not indicate the size depth or type of a service EZiSYSTEM How to Use the Locator 23 EZiISYSTEM How to Use the Locator 24 Detecting direction of the service Peak hold When activated peak hold will show the highest peak reading obtained during the pinpoint process The displayed reading can
41. indication does not guarantee the non existence of a service Services without a detectable signal may be present The Locators can only locate non metallic services such as plastic pipes typically used by the water and gas utilities with the use of appropriate accessories Precautions Always excavate with care Designed to increase the detection of services with no or little signals on them Generally Accessories work in conjunction with the Locator and Transmitter Designed to demonstrate the equipment is working satisfactorily in between service inter Functional Check vals Refer to Appendix A Functional Checks for more information EZiSYSTEM General Information EZiISYSTEM General Information 10 1 3 i Series Instruments and Accessories General information The i Series is a collection of products used to locate buried metallic and nonmetallic services i Series instruments overview a Locator b Transmitter i Series accessories over view a Conductive Rod non metallic service tracer b Extension Cable c Property Connection Set d Signal Clamp e Sonde Operating modes Electromagnetic signals Passive signals Active tracing Depth indication 1550 i650 i750 i550xf i650xf i750xf Current Measurement I550xf i650xf amp i750xf Wireless communication Bluetooth How to Use the Locator General Information e Passive modes Power and
42. measurement results if the product has been dropped or has been misused modified stored for long periods or transported Precautions Periodically carry out test measurements and perform tests indicated in the user manual particularly after the product has been subjected to abnormal use and before and after important measurements EZiSYSTEM Safety Directions 67 EZiISYSTEM Safety Directions 68 Z Danger Because of the risk of electrocution it is very dangerous to use the product in the vicinity of electrical installations such as power cables or electrical railways Precautions Keep at a safe distance from electrical installations If it is essential to work in this environ ment first contact the safety authorities responsible for the electrical installations and follow their instructions During dynamic applications for example stakeout procedures there is a danger of acci dents occurring if the user does not pay attention to the environmental conditions around for example obstacles excavations or traffic Precautions The person responsible for the product must make all users fully aware of the existing dangers The absence of a positive indication does not guarantee the non existence of a service Services without a detectable signal may be present The Locators can only locate non metallic services such as plastic pipes typically used by the water and gas utilities with the use of appropriate accessories Preca
43. minated to show failure mode Frequency Display Frequency LED illuminated to show frequency failure 103 EZiISYSTEM Functional Checks 104 ee N Warning e If the unit fails check the Transmitter s cable set is fully engaged and the clips are connected e Repeated failure will indicate a faulty unit which must be returned for service If any of these tests give no response or a significantly different response from normal the Transmitter should be returned for service The transmitter is capable of outputting potentially lethal voltages Precautions Care should be taken when handling exposed or non insulated connections including the connection cables sets the Earth Pin and the connection to the service Notify others who may be working on or around the service Functional test check list Functional Test Check List Unit Serial Number Comments Transmitter Test Operative Yes No N A Fail analysis Notes 1 Casing Return for repair Casing should be free of Replace damage Labels Battery cover and accessory cover Battery contacts Return for repair Replace Return for repair Replace Return for repair Body labels must be legible and intact Display label must be free of damage and tears Hatches must lock into place Contacts must be free of corrosion Audio Visual Return for repair All LEDs must illuminate and display test an audi
44. models signal Peak hold Assists in pinpointing a service by displaying the peak reading for a short period of time 2 2 Locator Overview Locator main parts a Display Panel Contains the operational controls b Speakers mounted internally left and right Active at power on and when a signal is detected c On Off Trigger Press and hold the trigger to activate the Locator Release the trigger to deactivate d Battery Hatch Release Pressing the release button unlocks the battery hatch allowing access to the battery compartment e Battery Compartment 6 x LR6 AA alkaline batteries are used Replace all f batteries when indicated f Case Foot me The case foot can be replaced if it is worn Contact your agency or Cable Detection author ised service workshop EZiSYSTEM How to Use the Locator 13 EZiISYSTEM How to Use the Locator Display panel overview a eS H ae g Bluetooth Status Indicator Symbol Static Bluetooth is enabled Symbol Flashing Bluetooth is paired No Symbol Bluetooth is disabled h Wrench 14 Signal Strength Indicator Indicates the response of the Locator to a signal service Mode Indicators Displays the selected mode Power Radio 8 kHz 33 kHz Auto 512 Hz and 640 Hz on xf models As shown from bottom to top Function Button Selects operating mode Light Sensor Automatically switches the displays backlight on
45. n mode 8 kHz 33 kHz combined 8 kHz and 33 kHz additionally 512 Hz 640 Hz on xf Transmitters This is the most efficient way of applying a signal to a service and should be used when ever possible The Transmitter s cable set or any of the available accessories are connected to the service which is to be traced or identified EZiSYSTEM How to Use the Transmitter 41 EZiISYSTEM How to Use the Transmitter 3 2 Transmitter main parts Transmitter Overview 42 w Oo A a b c d e Battery Cover Accessory Compartment Earth Pin Connection Socket Used to connect accessories directly to metallic services Standard crocodile clip cable set Frequency Control and Indicator Used to set the Transmitters frequency output LED illuminates to indicate selection Mute Control Used to silence the Transmitter Mode Display Indicates which mode is selected Induction or Connection Power Output Control and Indicator Press the control to set the Transmitters power output Level 1 minimum power output indicated by the bottom LED illuminated Level 4 maximum power output indicated by all LED s illuminated Default setting Level two On Off control Press to switch the transmitter on and off Speaker Changing the battery The battery indicator flashes to indicate a poor battery condition ihe the cover D type alkaline batteries or remove and recharge the battery
46. o pinpoint a buried manhole The Locator will pick up a pool of signal with a null point at the centre This is an accurate method but it is essential to ensure the Sonde is vertical sewer 8 8 1 Transport in the field Transport in a road vehicle Shipping Shipping transport of batteries 8 2 Product Care and Transport Transport When transporting the equipment in the field always make sure that you carry the product in its original transport container Never carry the product loose in a road vehicle as it can be affected by shock and vibration Always carry the product in its transport container and secure it When transporting the product by rail air or sea always use the complete original Cable Detection packaging transport container and cardboard box or its equivalent to protect against shock and vibration When transporting or shipping batteries the person in charge of the product must ensure that the applicable national and international rules and regulations are observed Before transportation or shipping contact your local passenger or freight transport company Storage Respect the temperature limits when storing the equipment particularly in summer if the equipment is inside a vehicle Refer to 10 Technical Data for information about tempera ture limits If the equipment is to be stored for a long time remove the alkaline batteries from the product in order to avoid the dange
47. of the rod using the Locator set to the same frequency S e Ensure there are no services below the ground when using the Earth Pin Use the Locator in advance e At least half the Conductive Rod needs to be uncoiled when in use Using the Conductive 1 Insert the rod into the pipe duct conduit or drain until the desired length is in place Rod in Sonde mode 2 Plug the Transmitter s cable set into the connection socket Connect the red cable to the positive terminal on the conductive rod connect the black cable to the negative terminal 3 Switch the Transmitter on and select the required power output level and frequency output A good level of tracing signal is indicated when the power output LED amp audible tone changes from pulsed to continuous The signal applies itself along the length of the Conductive Rod 4 Trace the length of the rod using the Locator set to the same frequency LE At least half the Conductive Rod needs to be uncoiled when in use EZiSYSTEM How to Use the Conductive Rod 51 EZiSYSTEM How to Use the Signal Clamp 52 5 How to Use the Signal Clamp 5 1 General Information Description The Signal Clamp provides a safe technique of applying a signal to services such as telecom cables etc It is connected to the Transmitter and then clipped around the service Supply is not interrupted by the applied signal 5 2 Signal Clamp Overview Signal Clamp main parts a a Transmitter plu
48. onnection socket The Transmitter s battery pack may get hot after prolonged use Precautions Allow the battery pack to cool down before removing If the product is improperly disposed of the following can happen e If polymer parts are burnt poisonous gases are produced which may impair health e If batteries are damaged or are heated strongly they can explode and cause poisoning burning corrosion or environmental contamination e By disposing of the product irresponsibly you may enable unauthorised persons to use it in contravention of the regulations exposing themselves and third parties to the risk of severe injury and rendering the environment liable to contamination e Improper disposal of silicone oil may cause environmental contamination Precautions The product must not be disposed with household waste Dispose of the product appropriately in accordance with the national regulations in force in your country Always prevent access to the product by unauthorised personnel Product specific treatment and waste management information can be downloaded from the Cable Detection home page at http www cabledetection co uk treatment or received from your Cable Detection dealer EZiSYSTEM Safety Directions 71 EZiISYSTEM Safety Directions 72 Z Warning 9 6 Description During the transport shipping or disposal of batteries it is possible for inappropriate mechanical influences to constitute a fire hazard Preca
49. r of leakage EZiISYSTEM Care and Transport 63 EZiSYSTEM Care and Transport 64 8 3 Cleaning and Drying Damp products Dry the product the transport container the foam inserts and the accessories at a temper ature not greater than 40 C 104 F and clean them Do not repack until everything is completely dry Cables and plugs Keep plugs clean and dry Blow away any dirt lodged in the plugs of the connecting cables 9 9 1 Description 9 2 Permitted use Adverse use Safety Directions General Introduction The following directions should enable the person responsible for the product and the person who actually uses the equipment to anticipate and avoid operational hazards The person responsible for the product must ensure that all users understand these direc tions and adhere to them Intended Use The products are intended to be used for the following applications EZiSYSTEM Safety Directions Detection and localization of underground services cables and metallic pipes Locator Detection and localization of a Sonde Transmitter Locator Detection and localization of Conductive Rod accessory Locator 1550 i650 1750 i550xf i650xf i750xf Estimation of the depth of an underground service a Sonde or Conductive Rod Locator with Bluetooth Data communication with external appliances Use of the product without instruction Use outside of the intended use and limits Disabling safety systems
50. readout will then indicate the Current Reading EZiSYSTEM How to Use the Locator 33 EZiISYSTEM How to Use the Locator 34 2 6 Bluetooth Pairing information Wireless Data Communication where applicable Bluetooth status is indicated on the locators display the Bluetooth symbol will be illumi nated when Bluetooth connectivity is available Data can be wirelessly transferred from a Bluetooth enabled Locator to a suitable data logging device enabling the operator to capture information about the Locator s status and the service depth When the Locator is paired to a suitable device the Bluetooth symbol will flash and the unit will transmit data periodically Important information for pairing e The Locator must be switched on throughout the process e Follow the instructions on the device for pairing Refer to the manufacturer s instructions Locator Name Model Number Serial Number for example 550 000001 Pass key 12345 e The Bluetooth symbol will flash continually when the devices have successfully paired e When a depth reading has been taken the Locator will display LOG To transfer the
51. reby Cable Detection Ltd declares that the Property Connection Set is in compli regulations ance with the essential requirements and other relevant provisions of Directive 1999 5 EC The declaration of conformity may be consulted at http www cabledetection co uk ce Class 1 equipment according European Directive 1999 5 EC R amp TTE can be C 4 placed on the market and be put into service without restrictions in any EEA member state e The conformity for countries with other national regulations not covered by the FCC part 15 or European directive 1999 5 EC has to be approved prior to use and opera tion EZiSYSTEM Technical Data 93 EZiSYSTEM Technical Data 94 10 6 Signal Clamp Technical Data Operating transmission 32 768 33 kHz frequencies when used with a signal transmitter set in 33 kHz mode Instrument dimensions 250 mm 9 8 Inches 142 mm 5 6 Inches Kf 100 mm 4 Inches Weight Instrument 0 354 kg 0 76 Ibs oo specifica Type Description ons Temperature Operating 20 C to 50 C 4 F to 122 F Storage 40 C to 70 C 40 F to 158 F Protection against Water Dust IP54 IEC 60529 and Sand Dust protected Conformity to national regulations EZiSYSTEM Technical Data Type Description Humidity 95 RH non condensing The effects of condensation are to be effectively counteracted by periodically drying out the product e Hereby Cable Detection Ltd decla
52. rence It also displays additional service and contact information as detailed Setting Description EST Performs a function check on the locators hardware and software displaying PAS if the Locator is within predefined tolerance or ERR if the locator is not H Z Switches hazard zone on or off VOL Adjust volume level 0 10 HLD Adjust peak hold duration 0 5 seconds SSI Displays a numeric signal strength indicator CST Adjusts display s contrast 0 15 M I Displays unit of measurement CAL Displays the next service date DD MM YY CON Displays supplier company name TEL Displays supplier company telephone number I D Displays the operator s name PWR Displays the power mode regional setting Refer to Appendix B World Frequency Zones for more information SR Displays unit serial number VER Displays software version CLK Displays the date and time held within the locators memory i600 i650 i700 i750 i600xf i650xf i750xf Format DD MM YY HH MM SS Accessing and adjusting the settings Setting LOG i600 i650 i700 i750 i600xf i650xf i750xf BT i600 i650 iGOOxf amp i650xf Setting COM 1700 1750 amp i750xf LST xf models Description Displays the last stored log number 001 to 999 Adjusts the Bluetooth output options Adjusts the locators Bluetooth or GPS settings PC Enables Bluetooth communication to Logicat Software
53. res that the Signal Clamp is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC The declaration of conformity may be consulted at http www cabledetection co uk ce Class 1 equipment according European Directive 1999 5 EC R amp TTE can be C placed on the market and be put into service without restrictions in any EEA member state e The conformity for countries with other national regulations not covered by the FCC part 15 or European directive 1999 5 EC has to be approved prior to use and opera tion 95 EZiISYSTEM International Limited Warranty 96 11 International Limited Warranty International Limited Warranty This product is subject to the terms and conditions set out in the International Limited Warranty which you can download from the Cable Detection home page at http www cabledetection co uk internationalwarranty or collect from your Cable Detec tion distributor The foregoing warranty is exclusive and is in lieu of all other warranties terms or conditions expressed or implied either in fact or by operation of law statutory or otherwise including warranties terms or conditions of merchantability fitness for a partic ular purpose satisfactory quality and noninfringement all which are expressly disclaimed Appendix A A 1 Checking the function Functional Checks Locator Functional Check Before any tests can be carried out it is vital to check the
54. stinguish by conventional locating techniques The highest current reading mA will be obtained when the locator is positioned over the service which has the transmitter attached to it N TO Additional information on the condition and layout of the service can be ascertained such as a fault in the service damage to the insulation or a connection off the service these are typically indicated by sudden reduction in the current reading EZiSYSTEM How to Use the Locator 31 32 EZiISYSTEM How to Use the Locator The signal current applied by the transmitter decreases at a uniform rate as it travels along the service This can help to identify the service layout as connections off it have a corresponding reduction in current A sudden reduction in current may indicate damage to the service LUULDUSUUULUEEUUOe ee See eee m o tt m te See m g y T y m y m m m I m o f o f m m y m m m fet mmm mmm mmm Taking a Current Measurement 1 Apply a signal to the service Refer to 3 How to Use the Transmitter for more informa tion 2 Select the mode to suit the transmitters output Position the Locator directly over and at 90 degrees to the direction of the service 3 Press and release the Button 4 The display readout will indi cate the depth of the service and the Line mode icon will be displayed 5 The display
55. the product meets the strict regulations and standards which are in force in this respect Cable Detection cannot completely exclude the possibility that other equipment may be disturbed There is a risk that disturbances may be caused in other equipment if the product is used in conjunction with accessories from other manufacturers for example field computers personal computers two way radios non standard cables or external batteries Precautions Use only the equipment and accessories recommended by Cable Detection When combined with the product they meet the strict requirements stipulated by the guidelines and standards When using computers and two way radios pay attention to the informa tion about electromagnetic compatibility provided by the manufacturer Disturbances caused by electromagnetic radiation can result in erroneous measurements Although the product meets the strict regulations and standards which are in force in this respect Cable Detection cannot completely exclude the possibility that the product may be disturbed by very intense electromagnetic radiation for example near radio Transmitters two way radios or diesel generators Precautions Check the plausibility of results obtained under these conditions If the product is operated with connecting cables attached at only one of their two ends for example external supply cables interface cables the permitted level of electromagnetic radiation may be exceeded and t
56. the service being traced 7 3 How to Locate a Service Using the Sonde Locating the Sonde 1 Walk in line with the suspected direction of travel observing the display The signal strength indicator will rise and fall as you pass over the ghost signal at the back of the Sonde the peak signal directly over the Sonde and the ghost signal at the front The numeric signal strength indicator will display its highest value when detecting the peak signal 2 Retrace your steps and position the locator directly over the peak signal Move the locator left and right until the highest numeric reading is obtained This reading will indicate the Sonde s precise location EZiSYSTEM How to Use the Sonde 61 EZiISYSTEM How to Use the Sonde 62 3 Depth indication refer to Sonde Depth in How to Use the Locator section Depth indication can be used with a suitable depth locator The locator must be posi tioned directly over the Sonde and in line with it rotate the locator on its axis to find the highest reading Press and hold the i Button for 2 seconds The depth of the Sonde will be displayed in the depth readout window and the Sonde mode icon will be visible beneath the display e For ease and convenience mark the ground every 3 to 4 metres e For ease of use practice the process above ground Tracing a walk through gt Ifa walk through sewer is being traced another method is to place the Sonde vertically for example t
57. ting mode There are three operating modes for onsite flexibility e 33 kHz for general usage e 8 kHz for medium range tracing and reduced coupling on to other services e Combined 8 kHz and 33 kHz Connection mode only is useful in congested areas when either 8 kHz or 33 kHz may provide a better result The best results can be simply achieved by switching modes on the Locator Plus two additional operating modes on the xf transmitters connection mode only e 640 Hz for long distance tracing and reduced coupling on to other services Generally used in Countries where the mains electrical frequency is 50 Hz e 512 Hz for long distance tracing and reduced coupling on to other services Generally used in Countries where the mains electrical frequency is 60 Hz Description Active tracing is a term frequently used when a Transmitter is used to apply a signal to a service enabling it to be traced The use of a Transmitter will greatly improve the detection of services especially ones which may not have a signal on them The signal from the Transmitter can be applied to services in two ways e Induction mode 8 kHz or 33 kHz Induction is a quick and simple way to apply a signal to a service without the need to make any physical connection to it The Transmitter uses an internal aerial to transmit the signal therefore it should be noted that the signal will apply itself to additional services within close proximity to the Transmitter e Connectio
58. tions e Hereby Cable Detection Ltd declares that the EZiTEX t100 t100xf t300 t300xtf is in compliance with the essential requirements and other relevant provisions of Direc tive 1999 5 EC The declaration of conformity may be consulted at http www cable detection co uk ce C Class 1 equipment according European Directive 1999 5 EC R amp TTE can be placed on the market and be put into service without restrictions in any EEA member state e The conformity for countries with other national regulations not covered by the FCC part 15 or European directive 1999 5 EC has to be approved prior to use and opera tion EZiSYSTEM Technical Data 87 EZiSYSTEM Technical Data 10 3 Typical detection range Tracing distance Operating transmission frequencies Instrument dimensions Weight 88 Conductive Rod Technical Data Both modes Line and Sonde Typical 3 0 m 10 ft 30 m 99 ft 50 m 165 ft 80 m 263 ft maximum Reel length dependant Dependent on Transmitter 13 mm 0 512 Inches 490 mm 19 3 Inches 210 mm 8 3 ches 440 mm 17 3 Inches Instrument 7 3 kg 16 1 Ibs Environmental specifica tions Conformity to national regulations EZiSYSTEM Technical Data Type Description Temperature Operating 20 C to 50 C 4 F to 122 F Storage 40 C to 70 C 40 F to 158 F Protection against Frame IP54 IEC 60529 Water Dust
59. tly different response from normal the Conductive Rod should be returned for service EZiSYSTEM Functional Checks 107 EZiISYSTEM Functional Checks 108 Functional test check list Unit Conductive Rod Test Functional Test Check List Serial Number Operative Yes No N A Comments Fail analysis Notes 1 Sonde mode Transmitter audio output does not go continuous Sonde mode Locator does not detect signal Line mode Locator does not detect signal Repair or replace cable set Return for repair Replace Return for repair Replace Faulty cable One or both internal wires are open or short circuit One or both internal wires are open or short circuit Tested by Date A 4 Checking the function Sonde Functional Check The purpose of the following procedure is to enable a user to verify the performance of the Sonde To carry out this test the following are required e A Locator to detect the signal e A work area free of services as illustrated 1 Inspection e Casing The casing should be free of significant damage with the sealing ring and the screw thread intact Once the general condition of the Sonde is established the self test can then be used to indi cate the basic unit function and state of the batteries 2 LED test Turn on the sonde the led display will illuminate 3 Battery check A dull LED and lack of dete
60. to the mains supply Precautions The Property Connection Set should be connected to the Transmitter before connecting to the mains supply Z Danger When using a Property Connection Set a hazardous signal may be present on the service or mains outlet causing personal harm Precautions Do not use on electrical services which have impaired or no insulation If in doubt do not use Replace damaged Property Connection Set cable assembly before use EZiSYSTEM How to Use the Property Connection Set 57 EZiISYSTEM How to Use the Sonde 58 7 7 1 Description er 7 2 Sonde main parts How to Use the Sonde General Information The Sonde is a dual frequency signal transmitter used to trace drains sewers and other non conductive services It can be attached to a range of equipment including drain rods boring tools and inspection cameras It is powered by a 1 5 V LR6 AA battery so unlike other accessories this does not require a connection to the transmitter The signal pattern transmitted from the Sonde is different to that which is radiated from a service transmitting a peak signal over its main body with a ghost signal at the front and back This requires the Sonde to be traced with its own unique method The i Series Locators feature a numeric signal strength indicator user setting SSI set to ON which will greatly improve the locating process The numeric signal strength indicator is shown in the display readout on the Loca
61. tor Sonde Overview a LED b Sonde body c LR6 AA battery d End cap and M10 connection point The thread on the Sonde is a male M10 and comes with adaptors to both British and Euro pean drain rods Changing the frequency Changing to 33 kHz mode output 1 aip W Xx k 10 sec Z 4 ia EZiSYSTEM How to Use the Sonde Unscrew and remove end cap Insert battery positive end first Refit end cap securely Hold Sonde upright Confirm green LED is continuous Wait approximately 10 seconds for the green LED to start flashing With the green LED flashing the Sonde is ready for use at 33 kHz 59 EZiSYSTEM How to Use the Sonde Changing to 8 kHz mode te KF K D QJ CDs Ro x X 60 Unscrew and remove end cap Insert battery positive end first Refit end cap securely Hold Sonde upright Confirm green light is continuous Rotate Sonde so the LED points down and wait approxi mately 1 second Rotate Sonde upright Confirm the amber coloured LED is continuous If LED remains green repeat from step 1 Wait approximately 10 seconds for the amber LED to start 4 y 5 flashing With the amber LED flashing the Sonde is ready for use at 5 8 kHz 10 sec 6 a 8kHz me Once the function of the Sonde has been checked with a Locator set to the same operating mode it can be attached to drain rods or other means of guiding it into
62. tor and Transmitter you will find a label that shows some important informa tion by means of illustrations You will find some of these illustrations in this manual too This should help to get a clear connection between the instrument label and the informa tion in this manual EZiISYSTEM General Information 8 1 2 Description i Series General Information Locators are used to detect buried conductive services emitting an electromagnetic signal which is generated by a current passing through the service Transmitters are used to apply a distinct signal to conductive services which may not radiate electromagnetic signals or may need to be traced for a specific purpose The Transmitter is required to make a depth or current measurement The Locators and Transmitters described within this manual will greatly increase the detec tion process and help to reduce the dangers and costs associated with service strikes But the very nature of electromagnetic location is dependent on the services being conductive metallic and radiating a signal as current flows through them It is important to remember that a Locator on its own will not detect all services and care should be taken when excavating It is generally accepted that a safe system of work should be adopted which would include planning the work in advance the use of utility maps the use of Locators and Transmitters and the use of safe digging practices The absence of a positive
63. uence GPS Search Mode i700 i750 amp i750xf A GPS search mode is activated as part of the start up test allowing the internal GPS module time to search for a GPS position GPS search mode is active following the start up test even if the locator is off the search mode will stop when a GPS position is obtained or a 12 minute search period has elapsed GPS search mode does not affect the locators performance and the locator can be used as normal throughout this search mode EZiSYSTEM How to Use the Locator 21 EZiISYSTEM How to Use the Locator 22 Locating process The locating process is split into three steps e Sweep Search e Pinpointing the service e Direction of the service Sweep Search K Auto mode combines the benefit of simultaneous detection in Power and Radio modes and helps to confirm the presence of services upon initial site occupation Improved defi nition of the service will be provided by single mode operation Define the area to be excavated 1 In Power mode cross the site from left to right keeping the Locator upright taking care not to swing the unit Turn through 90 degrees and repeat K Ensure that the Locator is held in an upright position and close to the ground 2 Continue the sweep until either a signal is located or you are satisfied that the area has been adequately tested K In the presence of a service emitting a traceable signal a tone will be emitted and the s
64. ure is to verify the performance of the Locator It is important that the test is conducted away from areas of electromagnetic interference or over buried services with a large signal radiating off them 1 Switch the Locator on 2 Whilst in Power mode hold down the Button until the settings are displayed 3 Using the Function Button toggle through the settings until EST is displayed 4 Press the i Button to activate the test 5 Observe the displayed output PAS means unit is within set tolerances ERR means unit is outside set tolerances and may need servicing e Repeat the test in a different location if the units displays ERR e The Locator will automatically repeat the function test if it fails e Repeated failure will indicate a faulty unit which must be returned for service This test can be carried out provided the depth of a service on the test area is known 1 Switch the Locator on and ensure that it is in 33 kHz mode 2 Position the Locator directly over and at right angle to the service 3 Press and release the Button to activate the depth measurement 4 Record the depth 5 If the depth reading deviates from the normal value or an error code is displayed the Locator should be returned for service se Locator should be returned for service If any of these tests give no response or a significantly different response from normal the Functional test check list Unit Locator Test Ser
65. utions Always excavate with care Only with a Locator with depth The depth reading might not reflect the real depth if your Locator picks up the signal induced into the service by the Transmitter This signal is radiated from the centre of the service This is even more important when the signal is produced by a Sonde lying in a large diam eter conduit Precautions Always compensate depth reading for service size Z Danger Z Danger The Locator may fail to detect electrical services in Power mode if an incorrect power setting is used Precautions Before use verify the Locator is setup to be compatible with mains frequency supply in your country Options are 50 or 60 Hz Refer to Appendix B World Frequency Zones User Manual for more information Contact your agency or Cable Detection authorised service workshop if your unit is incor rectly configured for your region Only with Transmitter A hazardous signal may be present on the connection plug of the Signal Clamp when clipped over a live service Precautions The clamp should be connected to the Transmitter before clamping around a live service Connecting the Transmitter s cable set to a live service can result in receiving an electric shock Precautions The Transmitter s cable set should never be connected directly to an electrical live service When using a signal clamp a hazardous signal may be present on the service causing personal harm
66. utions Before shipping the product or disposing of it discharge the batteries by running the product until they are flat When transporting or shipping batteries the person in charge of the product must ensure that the applicable national and international rules and regulations are observed Before transportation or shipping contact your local passenger or freight transport company High mechanical stress high ambient temperatures or immersion into fluids can cause leakage fire or explosions of the batteries Precautions Protect the batteries from mechanical influences and high ambient temperatures Do not drop or immerse batteries into fluids If battery terminals come in contact with jewellery keys metallised paper or other metals short circuited battery terminals can overheat and cause injury or fire for example by storing or transporting in pockets Precautions Make sure that the battery terminals do not come into contact with metallic objects Only Cable Detection authorised service workshops are entitled to repair these products Electromagnetic Compatibility EMC The term Electromagnetic Compatibility is taken to mean the capability of the product to function smoothly in an environment where electromagnetic radiation and electrostatic discharges are present and without causing electromagnetic disturbances to other equip ment Electromagnetic radiation can cause disturbances in other equipment Although
67. value similar to test unit Gives same result as test unit 10 accuracy Tested by Date A 2 Transmitter Functional Check Checking the function The purpose of the following procedure is to verify the performance of the signal Trans mitter Before any tests can be carried out it is vital to check the status of the unit its batteries and basic functionality To carry out this test the following are required e The Transmitters cable Set e A fully charged battery pack 1 Inspection Casing Cable Set Labels Battery hatch Battery holder Battery contacts The casing should be free of significant damage The cable set should be free of damage to the cable s insula tion and clip shrouds The terminals should be free of corrosion Body labels must be legible and intact Display label must be free of damage and tears The hatch must lock into place All the battery contacts and springs on the holder must be free of corrosion and the holder in good condition The battery contacts must be free of corrosion Once the general condition of the Transmitter is established the Audio Visual test can be performed EZiSYSTEM Functional Checks 101 EZiISYSTEM Functional Checks 102 2 Audio Visual display test Turn on the Transmitter All LED s will illuminate and the speaker will emit a tone All LEDs must be operative and an audible output must be heard 3 Battery check The battery ind
68. ve electricity cables It is connected to the service via a mains plug outlet and provides a trace able signal Supply is not interrupted by the applied signal and the risk of serious injury is greatly reduced 6 2 Property Connection Set Overview Property Connection Set main parts A OR P a Mains plug connector b In line isolator c Transmitter plug connector EZiSYSTEM How to Use the Property Connection Set 55 EZiSYSTEM How to Use the Property Connection Set 56 6 3 How to Locate a Service Using the Property Connection Set Using the Property Connection Set Connect the Property Connection Set to the Transmitter 2 Connect the Property Connection Set to a live mains outlet Ensure the switch on the mains Is on 3 Switch the Transmitter on and select the required power output level set the frequency output to correspond with the Property Connection Set A good level of tracing signal is Indicated when the audible tone and power output LED are continuous 4 Trace the length of the service using the Locator set to the same frequency OS e The mains supply must be live and switched on for correct operation e Ensure the Transmitter s frequency output is comparable to that of the Property Connection Set e Check the Property Connection Set type plate for the frequency rating Z Danger A hazardous signal may be present on the connection plug of the Property Connection Set when connected
69. ver the service with the arrows running in line with the suspected direction of the service The tracing signal is induced directly onto the service from the internal aerial Trace the suspected path of the service using the Locator set to the same frequency Refer to 2 How to Use the Locator for more information Work at least 10 m 33 ft away from the Transmitter to avoid airborne signals Reposi tion the Transmitter if required Coupling efficiency is best at 33 kHz The signal will couple to adjacent services dependent on depth and direction Reducing the signal output can help to increase the battery life and the Transmitter is less likely to apply a signal to an adjacent service Using the Transmitter in Connection mode Plug the Transmitter s cable set into the connection socket Connect the black cable to the Earth Pin ensuring that no services are below push the Earth Pin into the ground Connect the red cable to the service Switch the Transmitter on observe the Connection mode LED is illuminated and the battery level is adequate Change batteries when indicated Select the required power output level and frequency output A good level of tracing signal is indicated when the power output LED amp audible tone changes from pulsed to continuous Trace the signal using the Locator set to the same operating mode Refer to 2 How to Use the Locator for more information
70. x EZISYSTEM User Manual Version 1 0 English EZiSYSTEM Introduction 2 Introduction Purchase Congratulations on your purchase of an EZiISYSTEM instrument This manual contains important safety directions as well as instructions for setting up the product and operating it Refer to 9 Safety Directions for further information Read carefully through the User Manual before you switch on the product Product identification The model and the serial number of your product are indicated on the type plate Enter the model and serial number in your manual and always refer to this information when you need to contact your agency or Cable Detection authorised service workshop Type Serial No Symbols The symbols used in this manual have the following meanings Type Description Z Danger Indicates an imminently hazardous situation which if not avoided will result in death or serious injury N Warning Indicates a potentially hazardous situation or an unintended use which if not avoided could result in death or serious injury L Caution Indicates a potentially hazardous situation or an unintended use which if not avoided may result in minor or moderate injury ES Important paragraphs which must be adhered to in practice as they enable the product to be used in a technically correct and efficient manner Validity of this manual This manual applies to all EZISYSTEM instruments which are the I S
Download Pdf Manuals
Related Search
Related Contents
Samsung AR09FSFPESNN User Manual DEMUSEtool – user manual Sony VGN-TZ185N/WC Safety Information GE864 Harware User Guide Descargar más información sobre Luces Samsung Galaxy NotePro (12.2", 4G) Käyttöopas 取扱説明書 MANUAL DE USUARIO - Ministerio de Hacienda American Standard 2775.XXXW Series User's Manual SMS Smart Media Solutions WH 3D incl FUNC H Unisl Bl Copyright © All rights reserved.