Home

to the PDF file.

image

Contents

1. iii What is BSI_Config BSL Config is a free configuration software package for performing basic configuration of your ControlWave or Network 3000 controller flow computer or transmitter It may be used with the following products e ControlWave series controllers e Network 3000 series including DPC 3330 DPC 3335 RTU 3310 RTU 3305 and 3530 TeleRTU controllers plus 3530 series TeleFlow TeleCorrector and TeleRecorder flow measurement products e 3808 MVT Transmitter How do Install BSI_Config IMPORTANT The standalone version of BSI_Config cannot be installed on the same PC as the OpenBSI Network Edition If you intend to install the full OpenBSI package onto a PC that already includes the standalone version of BSI_Config you should remove BSI_Config first l Insert the OpenBSI CD ROM in your CD ROM drive 2 If your CD ROM drive has autorun enabled skip to the next step Otherwise use Windows Explorer to locate the file BROWSER EXE in the root directory of the CD Double click on BROWSER EXE When the CD browser screen appears choose the Install OpenBSP option 3 A screen reminding you to close all other programs and warning you that older OpenBSI versions will be removed will appear Click on Next gt 4 A license agreement screen will appear Review the agreement using the scroll bar to bring it into view Click on I accept the terms of the license agreement in order to proceed The
2. Pinos 01180 Mexico D F Mexico T 52 55 5809 5300 F 52 55 2614 8663 www EmersonProcess com Remote Emerson Process Management Ltd Remote Automation Solutions Blackpole Road Worcester WR3 8YB United Kingdom Phone 44 1905 856950 Fax 44 1905 856969 www EmersonProcess com Remote Emerson Process Management AP Pte Ltd Remote Automation Solutions Division 1 Pandan Crescent Singapore 128461 Phone 65 6770 8584 Fax 65 6891 7841 www EmersonProcess com Remote NOTICE Remote Automation Solutions RAS division of Emerson Process Management shall not be liable for technical or editorial errors in this manual or omissions from this manual RAS MAKES NO WARRANTIES EXPRESSED OR IMPLIED INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THIS MANUAL AND IN NO EVENT SHALL RAS BE LIABLE FOR ANY INCIDENTAL PUNITIVE SPECIAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO LOSS OF PRODUCTION LOSS OF PROFITS LOSS OF REVENUE OR USE AND COSTS INCURRED INCLUDING WITHOUT LIMITATION FOR CAPITAL FUEL AND POWER AND CLAIMS OF THIRD PARTIES Bristol Inc Bristol Babcock Ltd Bristol Canada BBI SA de CV and the Flow Computer Division are wholly owned subsidiaries of Emerson Electric Co doing business as Remote Automation Solutions RAS a division of Emerson Process Management FloBoss ROCLINK Bristol Bristol Babcock ControlWave TeleFlow an
3. RETURNED EQUIPMENT WARNING When returning any equipment to RAS for repairs or evaluation please note the following The party sending such materials is responsible to ensure that the materials returned to RAS are clean to safe levels as such levels are defined and or determined by applicable federal state and or local law regulations or codes Such party agrees to indemnify RAS and save RAS harmless from any liability or damage which RAS may incur or suffer due to such party s failure to so act ELECTRICAL GROUNDING Metal enclosures and exposed metal parts of electrical instruments must be grounded in accordance with OSHA rules and regulations pertaining to Design Safety Standards for Electrical Systems 29 CFR Part 1910 Subpart S dated April 16 1981 OSHA rulings are in agreement with the National Electrical Code The grounding requirement is also applicable to mechanical or pneumatic instruments that include electrically operated devices such as lights switches relays alarms or chart drives EQUIPMENT DAMAGE FROM ELECTROSTATIC DISCHARGE VOLTAGE This product contains sensitive electronic components that can be damaged by exposure to an electrostatic discharge ESD voltage Depending on the magnitude and duration of the ESD this can result in erratic operation or complete failure of the equipment Read supplemental document S14006 for proper care and handling of ESD sensitive components Remote Automation Solutions A Division
4. and or the MVT GPT pressure transducer for the following products e 3508 TeleTrans Transmitter e 3808 MVT Transmitter Firmware Version 1 5 or newer e 3530 10B TeleFlow Electronic Gas Measurement Computer e 3530 20B TeleFlow Plus e 3530 45B TeleRecorder e 3530 50B TeleFlow Corrector e 3530 55B TeleRecorder e ControlWave EFM e ControlWave GFC e ControlWave XFC How to Start TechView Click on Start gt Programs gt OpenBSI Tools gt TechView Where to find detailed instructions on how to use TechView Please see the TechView User s Manual document D5131 3 BSI_Config User s Guide What is the Diagnostics Program Used For The Diagnostics program also known as WINDIAG can be used to check for hardware faults It can test memory I O and the CPU for the RTU 3305 RTU 3310 DPC 3330 DPC 3335 and the Control Wave series The Diagnostics program is NOT used with the 3530 series TeleFlow family of products however How to start the Diagnostics Program Click on Start gt Programs gt OpenBSI Tools gt Common Tools gt Diagnostics Where to find detailed instructions on how to use the Diagnostics Program Please see WINDIAG Windows Diagnostics for Bristol Controllers document D4041A for detailed information on how to use the Diagnostics program What are the Web_BSI for Tele Products Web Pages Used For The TeleFlow TeleCorrector TeleFlow 2 Run TeleRecorder and 3808 MVT Transmitter each have a
5. controls Control View allows you to connect to the ControlWave upload the HTML files to your PC using FTP and launch Internet Explorer to allow you to view the HTML pages with their associated data from the ControlWave Files are downloaded to the ControlWave using OpenBSI s 1131 Downloader Files are downloaded to the ControlWave s FLASH memory using the 1131 Downloader provided with OpenBSI Users must select the Download User Files option in the Downloader prior to starting the download The Downloader takes all files in the directory defined by the User Files Path and downloads them to the ControlWave pa ControlWave Downloader File View Help Node Cw2 Username SYSTEM Password Project Path Check Download User Files when you User Files Path c OpenBSI Downloads CW2 ControlVie Browse Path download files to the ControlView file k i cit area of the ControlWave s flash memory For Help press Fi The User Files Path should follow the format shown below OpenBSI Downloads project_name Control View BSI_Config User s Guide 6 where project_name is the basename of the ControlWave project The folder containing the files to be downloaded must be a sub directory of projectname called ControlView So for example if the ControlWave project name is STATION3 then the folder containing the files to be downloaded to FLASH should be called OpenBSI Downloads STATION3 Contro
6. of Emerson Process Management 1100 Buckingham Street Watertown CT 06795 Telephone 860 945 2200 Emerson Process Management Training GET THE MOST FROM YOUR EMERSON INSTRUMENT OR SYSTEM e Avoid Delays and problems in getting your system on line e Minimize installation start up and maintenance costs e Make the most effective use of our hardware and software e Know your system As you know a well trained staff is essential to your operation Emerson offers a full schedule of classes conducted by full time professional instructors Classes are offered throughout the year at various locations By participating in our training your personnel can learn how to install calibrate configure program and maintain your Emerson products and realize the full potential of your system For information or to enroll in any class go to http www EmersonProcess com Remote and click on Educational Services or contact our training department in Watertown at 860 945 2200 Table of Contents What 5 BSI Conlin aa 1 How do 1 Install BSI Cone nie 1 What is incida in BSI Conlin ee 2 What is Tech View Used For nennen 2 How to Stat TEEN ER MMM 3 Where to find detailed instructions on how to use Tech View ooooooooccccoccccnonoccconncnononcccnnnccnnn nos 3 What is the Diagnostics Program Used For cccccccssssssscssssssscscssssssccssssssccsssssessscsssssecees 4 How o sart ne Diazanses Freie en zn een Where to find det
7. only one file in the ControlView area available for uploading it will automatically be uploaded and its application will be launched e From the list box in the Select File to View dialog Select which file you want box choose the file you want to view and click on to upload and click on OK OK That file will be uploaded to the PC and the application associated with that file will be EE ok 21 launched to view the file ra Cancel NOTE If file being uploaded is a zipped compressed file the file will automatically be uncompressed and the application launched will depend on entries made in the STARTUP INI file BSI_Config User s Guide 10 What is LocalView Used For LocalView is a standard OpenBSI utility used for local communications with a ControlWave or Network 3000 controller As part of BSI_ Config LocalView is primarily used for setting various configuration parameters of the controller such as the addresses used for communications the default baud rate for communication ports when the unit is first powered on etc It can also be used for upgrading the system level firmware in the unit if that is required however some units require a special cable for that purpose The table below summarizes the various uses of Local View as part of the BSI_Config package CONTROLLER TYPE HOW TO SET RTU HOW TO UPGRADE SYSTEM CONFIGURATION FIRMWARE PARAMETERS Mode requires FLASH cable RTU 3310 DPC 333
8. 0 DPC 3335 with Use hardware switch Use LocalView in FLASH Mode 386EX Real Mode CPU or 386EX jumper settings requires FLASH cable Protected Mode CPU with PLSO2 PLX02 or earlier system firmware RTU 3310 DPC 3330 DPC 3335 with Use LocalView in Configure Use LocalView in FLASH Mode 386EX Protected Mode CPU and PLS03 Mode or NetView Some requires FLASH cable PLX03 PESO3 PEX03 or newer system hardware switch jumper firmware settings are also applicable EGM 3530 xx TeleFlow or RTU 3530 xx Local Address only can be Use LocalView in FLASH Mode TeleRTU set via LocalView in Local requires FLASH cable Mode or via NetView from Local View NetView LocalView in FLASH Mode How to Start LocalView Click on Start gt Programs gt OpenBSI Tools gt Local View Where to find detailed instructions on how to use LocalView Please see Chapter 5 of the OpenBSI Utilities Manual document D508 1 for detailed information on how to use the LocalView program and the Flash Configuration Utility Please note that access to other OpenBSI Utilities via LocalView s Local Mode such as DataView the Downloader Communication Statistics etc is only available if you have purchased and loaded OpenBSI Network Edition lI BSI_Config User s Guide What is the System Firmware Downloader Each ControlWave controller ships from the factory with system firmware pre installed Emerson periodically releases new versions of the sys
9. User Manual Document D5128 Part D301428X012 May 2010 OpenBSI Version 5 8 BSI Config User s Guide S Remote Automation Solutions EM ERSON www EmersonProcess com Remote IMPORTANT READ INSTRUCTIONS BEFORE STARTING Be sure that these instructions are carefully read and understood before any operation is attempted Improper use of this device in some applications may result in damage or injury The user is urged to keep this book filed in a convenient location for future reference These instructions may not cover all details or variations in equipment or cover every possible situation to be met in connection with installation operation or maintenance Should problems arise that are not covered sufficiently in the text the purchaser is advised to contact Emerson Process Management Remote Automation Solutions division RAS for further information EQUIPMENT APPLICATION WARNING The customer should note that a failure of this instrument or system for whatever reason may leave an operating process without protection Depending upon the application this could result in possible damage to property or injury to persons lt is suggested that the purchaser review the need for additional backup equipment or provide alternate means of protection such as alarm devices output limiting fail safe valves relief valves emergency shutoffs emergency switches etc If additional information is required the purchaser is advised to contact RAS
10. ailed instructions on how to use the Diagnostics Program u ee 4 What are the Web_BSI for Tele Products Web Pages Used For e sesessecssocssoceccocesseessecesosee 4 How to call up the Web Pages for Tele Pla iii a el 4 Where to find instructions on how to use these web pages en 5 What isthe Control File VERE seine 6 Files are downloaded to the ControlWave using OpenBSI s 1131 Downloader 6 Using the ControlView File Retrieval Utility oooocomosssss 8 Starting the ControlView File Retrieval Utility 3 Methods oooooonoccnoccnonccconnconcnonnononccnncnnnoos 8 Establishing a Connection Between the ControlWave and Control View csseeeseeeeee 9 What is Local View Used For iras 11 Ea o A 11 Where to find detailed instructions on how to use Local Vie W oooconocccnoncccnoncccnnncnononcccnonnncnono 11 What is the System Firmware Downloader eesooessoesscecssecssecssocsccocecocessecesccesoccesocescosesssessee 12 How to Start the Systemi Firmware Divine 12 Where to find detailed instructions on how to use the System Firmware Downloader 12 Whatis the Reset ControlWave Tool eiserne 13 How t Start the Reset ContolWaye Tool ea ii 13 Where to find detailed instructions on how to use the Reset ControlWave Tool 13 What the Debus lata TE ee 14 How to Start the Debug Info Tool AA aie 14 Where to find detailed instructions on how to use the Debug Info Tool s es 14
11. can then select a file for uploading and ControlView will automatically upload the file and launch the Windows M application associated with that file type Starting the ControlView File Retrieval Utility 3 Methods e Method 1 If you are in LocalView or NetView you can right click on the icon for the controller then choose RTU gt Control View e Method 2 You can start the utility by clicking on Start gt Programs gt OpenBSI Tools gt ControlWave Tools gt ControlView e Method 3 Advanced users may choose to start Control View from the command line Command line parameters must be entered in the order shown below If you omit a parameter entirely you cannot enter any of the parameters after 1t Once the program starts you will then be prompted to enter the omitted parameters ControlView RTUname IPAddress Username Password Filename where RTUname 1s the target RTU from which you are uploading the file IPAddress is the IP address of the target RTU If you know the RTUname and it s defined in the network but you don t know the IP address you can enter 0 0 0 0 here username a valid username for accessing this ControlWave unit password The password for the user named in username filename The name of the file you want to upload using Control View Once you have successfully established communications with the RTU by selecting a node name when running LocalView or NetView the IP address associated with that no
12. d Helicoid are trademarks of RAS AMS PlantWeb and the PlantWeb logo are marks of Emerson Electric Co The Emerson logo is a trademark and service mark of the Emerson Electric Co All other trademarks are property of their respective owners The contents of this publication are presented for informational purposes only While every effort has been made to ensure informational accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or their use or applicability RAS reserves the right to modify or improve the designs or specifications of such products at any time without notice All sales are governed by RAS terms and conditions which are available upon request 2010 Remote Automation Solutions division of Emerson Process Management All rights reserved EMERSON
13. de will be saved in the Windows Hosts file Because of this if you subsequently use ControlView to upload files you can enter a node name without LocalView or NetView running because that node name will automatically be resolved to an IP address stored in the Hosts file and will work so long as that IP address remains accurate NOTE The Hosts file is updated automatically by Windows networking software do NOT attempt to manually edit the Hosts file yourself BSI_Config User s Guide 8 Establishing a Connection Between the ControlWave and ControlView To establish a connection with the ControlWave you must e Select the button to the right of the RTU Name field then enter the ControlWave s node name in the RTU Name field Or use the list control to select it if it appears in the history list of node names If the name doesn t appear in the list and LocalView NetView are currently running you should first add the name to the list by clicking on the BSI RTUs button and selecting the name from the Select New Node dialog box Descriptor Select New Node Ed Cancel Controlw ave 120 0 77 1 Or e Select the button to the right of the IP Address field then enter the ControlWave s IP address in the IP Address field Or use the list control to select it if it appears in the history list of IP addresses Select this button and enter the IP address Or Select th
14. et of icons for accessing Web_BSI pages for the Tele Products will appear on your Windows desktop What is included in BSI_Config BSI_Config includes the following major components TechView program Diagnostics program Web_BSI for TeleProducts ControlView File Viewer LocalView program System Firmware Downloader Reset ControlWave Debug Info What is TechView Used For TechView is a standalone software package that allows a technician to Calibrate Bristol transmitter s either locally bench configuration or via communication with the transmitter s master controller RTU Perform certain basic configuration operations on a controller flow computer or transmitter such as changing the local address or group number BSI_Config User s Guide 2 e Collect real time or historical data from the controller flow computer or transmitter e Start other OpenBSI programs or utilities to perform other activities such as the Flash Configuration Utility e Perform on line edits to signal lists and to the structure of archive files in ControlWave series controllers Requires 4 60 or newer ControlWave firmware Typically the Tech View software would be installed on a portable laptop computer to allow the technician to bring it to the site of the RTU transmitter It could also be installed on a desktop computer in a lab for bench configuration of a transmitter TechView may be used to calibrate the RTD temperature circuitry
15. is button and enter the RTU name You cannot enter both the RTU name and IP address Name Address Connection 4 A RTU Name cnic p Cc IP Address 7 er came y Clear History You must provide re N a valid username Flsemame system password combination pseu eig for accessing the a A ControlWave unit ZB The list controls allow you to call up previous entries To erase the previous entries click on Clear History Click on Connect to establish the connection and display the files available for uploading When you upload a file to the PC itis stored in a temporary directory Clear Cache deletes all files in that temporary directory If LocalView or NetView is running you can select an RTU name by clicking on BSI RTUs to call up the Select New Node dialog box NOTE Entering an RTU name will only work if when you Select it that name can be resolved to an IP address This means that the node name must be mapped to an IP 9 BSI_Config User s Guide address in the Windows Hosts file This mapping occurs by running LocalView NetView when you connect the very first time using a node name or by selecting from the BSI RTUs button in Control View while NetView or LocalView are running You should NOT attempt to edit the Hosts file yourself e Click on Connect and the utility will display a list of files available for uploading from the ControlWave If there is
16. l View IMPORTANT If the files you are downloading are to be compressed into a zip file you must include a STARTUP INI file within the zip file which identifies which application should be launched when the files are unzipped This file takes the format STARTUP File xxxxx yyy Program program_name where xxxxx yyy is the name of one of the zipped files program_name is the name of the program to be launched by Control View once the zipped file is unzipped If the directory containing the program is not part of the standard Windows PATH statement you must enter the entire path and filename of the program executable here Example STARTUP INI File STARTUP file mymenu htm program iexplore NOTE Control View only uses the program entry in the STARTUP INI file if it is unable to choose a program based on the Windows file association 7 BSI_Config User s Guide Using the ControlView File Retrieval Utility ControlView establishes a connection with a particular ControlWave controller and uploads selected user files from the ControlWave to the PC To establish the connection the user must provide an IP address or 1f LocalView or NetView are running the user may optionally provide a node name from the currently active NETDEF file Once the connection is established the ControlView File Retrieval Utility will display the contents of the ControlView folder on the ControlWave for the user The user
17. late Help Live Value Calibrate Zerg Calbrate Operating Span Bad Signal Name Found od E i In other web pages help is available by Calibrate Differential Pressure DP clicking on a dedicated Help link or Run 2 by clicking on the title of the web page Differential P File Edit Bookmark Options Help Data ta Comenta Seach Back Bint Live Valu Calibration of the Static Pressure sensor involves the followir 1 Vent the HI and LO input ports of the DP body to a differential The SP sensor is connected to the HI side o Bad Signal Na 2 Observe the Live Value reading and wait for it t 3 Click on the Calibrate Zero button to calibrate the 5 BSI_Config User s Guide What is the ControlView File Viewer The ControlWave series of process automation controllers can store user created files in FLASH memory These could include HTML files ZIP files etc The underlying file transfer between the ControlWave and the PC is accomplished using the industry standard File Transfer Protocol FTP Beginning with OpenBSI Version 5 3 Service Pack 2 a free ControlWave file retrieval utility called ControlView is provided to retrieve these files from the ControlWave copy them to the PC and launch the associated application program for those files For example if you have created HTML pages for displaying signal values from the ControlWave using OpenBSI s ActiveX
18. n click on Next gt de Now you must choose the installation directory on your computer where OpenBSI packages will be installed Either accept the default or click on Browse to specify a new directory Then click on Next gt 6 On the next screen use the check boxes to select BSI Config as well as any other package s you would like to install 1 BSI_Config User s Guide 10 Once you have made your choices click on Next gt On the next screen you can specify if desired different directories for storage of OpenBSI data and configuration files Now click on Next gt This is your last opportunity to make any changes prior to starting the installation If you want to make changes you can use the lt Back button to go back to earlier pages If you are ready to perform the installation click on the Install gt button and the installation process will begin Be patient as it may take several minutes to install all of the different utilities depending upon which you have chosen When the installation has completed you will be prompted to re boot your computer which must be done in order for BSI Config to function properly If you choose not to re boot now you must do so before running BSI Config Click on Finish and the installation will be complete and re boot will proceed if you chose to do it now After re boot an OpenBSI Tools menu selection will be added to your Windows Start Programs menu and a s
19. ntrolWave Designer Programmer s Handbook document D5125 for detailed information on how to use the Reset ControlWave Tool 13 BSI_Config User s Guide What is the Debug Info Tool The Debug Info tool is intended solely for use by Emerson Development Engineering and Technical Application Support personnel or by customers being directly assisted by these personnel The ControlWave Debug Information tool retrieves information such as e Contents of internal memory e Contents of user stack memory e Contents of messages sent received via a particular port similar to a Data Line Monitor e RBE information How to Start the Debug Info Tool Click on Start gt Programs gt OpenBSI Tools gt Debugging Tools gt ControlWave Debug Info Where to find detailed instructions on how to use the Debug Info Tool Please see Appendix A of the ControlWave Designer Programmer s Handbook document D5125 for information on this tool BSI_Config User s Guide 14 BSI_Config User Manual D5128 May 2010 Emerson Process Management Remote Automation Solutions 1100 Buckingham Street Watertown CT 06795 Phone 1 860 945 2262 Fax 1 860 945 2525 www EmersonProcess com Remote Emerson Process Management Remote Automation Solutions 6338 Viscount Rd Mississauga Ont L4V 1H3 Canada Phone 905 362 0880 Fax 905 362 0882 www EmersonProcess com Remote Emerson Process Management SA de CV Calle 10 145 Col San Pedro de los
20. set of standard web pages for configuration purposes These web pages include controls for entering setup parameters calibrating sensors etc NOTE When signing on to a 3808 MVT transmitter only enter a password username password combinations are not supported How to call up the Web Pages for Tele Products After installation of BSI_Config is complete a set of icons for BI ang alx accessing these web pages will be created inside a folder called ie ae gt BSI_Config on the Windows desktop Se Sp E io TeleCorrector TeleFlow Simply double click on the icon and LocalView will be started to activate the web page mA TeleFlowT TeleRecorder 5 object s 11 66KB BSI_Config User s Guide 4 You will be prompted to enter the local address for the TeleFlow product The default local address is 1 Then RARA click on OK and the associated web page will appear RTU that ron er eae 7 Where to find instructions on how to use these web pages The web pages include embedded help information In some web pages help is available for each individual field by right clicking on the field Right click on a field to see if help is available Fie Edit View Favorites Tools Help e gt A Back konward Stop Refresh Home Search Favorites History Mail Print Address e D OpenBSI WebT eleFlowT woRun WebT eleFlowTwoRun htm 4 Calibrate Differential Pre Run 2 es Differential Pressure g Data P
21. tem firmware to introduce new features to the product or to correct problems with existing firmware In order to take advantage of these new features and corrections you need the ability to install the new system firmware This can be accomplished via various methods including the System Firmware Downloader NOTE The System Firmware Downloader is NOT used for downloading your ControlWave project for information on that please see Chapter 7 of the OpenBSI Utilities Manual document D508 1 How to Start the System Firmware Downloader Click on Start gt Programs gt OpenBSI Tools gt ControlWave Tools gt Remote Firmward Download Where to find detailed instructions on how to use the System Firmware Downloader Please see Appendix J of the OpenBSI Utilities Manual document D508 1 for detailed information on how to use the System Firmware Downloader System firmware may also be installed via Flash Mode in LocalView or using Hyperterminal See your hardware documentation for more information BSI_Config User s Guide 12 What is the Reset ControlWave Tool Changes to certain configuration parameters require you to reset or reboot the ControlWave The Reset ControlWave tool allows you to do this How to Start the Reset ControlWave Tool Click on Start gt Programs gt OpenBSI Tools gt Debugging Tools gt Reset ControlWave Where to find detailed instructions on how to use the Reset ControlWave Tool Please see the Co