Home
Hotwire thermo-anemometer VT110 - VT115
Contents
1. displays on screen Press again on OK the average calculation is launched End displays on screen and AVG blinks Press on OK to end the average calculation the average displays Press again on OK to display the maximum and minimum values measured during the average calculation Press on On Off Esc to exit the average function and return to the measurements display MEASURE AND DISPLAY THE AIRFLOW It s possible to measure and display the airflow in place of the velocity The device is on and displays the velocity and temperature measurements gt v v v v v Press on Select MODE blinks Press on OK the mode currently used blinks at the bottom of the screen Press on Select to select the FLOW mode Press on OK CONE blinks on screen press on Select to make appear RECT then CIRC Press on OK to select RECT or CIRC according to the type of sheath or cone CONE for a measurement with an airflow cone If RECT or CIRC is selected the measuring unit of the type of sheath displays Press on Select to select the unit mm or inch then press on OK to adjust the section size e If the type of selected sheath is circular DIAM displays and the first digit blinks Press on Select to select its value then press on OK to validate Perform the same procedure to select the value of the
2. 30 45 60 75 90 105 120 minutes or OFF gt Press on OK to validate gt Press on On Off Esc to return to the measurement display ox BN AUTO OFF OFF Activate or deactivate the keys beep The device is on and displays the measurements gt Press on Select until BEEP blinsk on screen gt Press on OK OFF or ON blinks on screen gt Press on Select to activate the keys beep ON or deactivate the keys beep OFF gt Press on OK to validate gt Press on On Off Esc to return to the measurement display SEL SEL BEEP ok _ BEEP gt Stet gt on P SEL ON ON OFF ACTIVATE THE BACKLIGHT The device is on and displays the measurements gt Press on Backlight B to activate the device backlight gt To deactivate the backlight press again on Backlight CHANGE THE BATTERIES gt Remove the front part at the back of the device gt Change the old batterers by AAA LRO3 1 5 V batteries gt Replace the front 1 Once returned to KIMO required waste collection will be assured in the respect of the environment in accordance to 2002 96 CE guidelines relating to WEEE EXPORT DEPARTMENT Boulevard de Beaubourg Emerainville BP 48 77312 MARNE LA VALLEE CEDEX 2 Tel 33 1 60 06 69 25 Fax 33 1 60 06 69 29 Q Qualit AFNOR CERTIFICATION NTang portable VT110
3. following digits to return to the previous digit press on On Off Esc When the last digit is adjusted press on OK to validate The device returns to the display of airflow and temperature measurements e If the type of selected sheath is rectangular LENGT displays and the first digit blinks e Press on Select to select its value then press on OK to validate Perform the same procedure to select the value of the following digits to return to the previous digit press on On Off Esc When the last digit is adjusted press on OK WIDTH to adjust the width also displays on screen perform the same procedure to select the digits value when the last digit is adjusted press on OK to validate The device returns to the display of airflow and temperature measurements If CONE is selected CONE displays on screen and the type of cone blinks K35 K75 K120 K150 Press on Select to select the type de cone then press on OK to validate The device returns to the display of airflow and temperature measurements T The length the width and the diameter of the section are adjustable from 1 to 3000 mm FREEZE THE MEASUREMENT During a measurement gt gt Press on Hold min max to freeze the measurement Hold displays on screen and the measurements of velocity or airflow and of temperature are frozen Press on On Off Esc to return to the measurements di
4. VT115 10 06 14 RCS 24 P rigueux 349 282 095 Non contractual document We reserve the right to modify the characteristics of our products without prior notice
5. KIMO INSTRUMENTS Pressure Temperature Humidity Air velocity Airflow Sound level Hotwire thermo anemometer VTO VTB DESCRIPTION OF THE DEVICE OK key Backlight key On Off Esc key Select key Hold min max key PERFORM A MEASUREMENT gt Turn on the device by pressing on On Off Esc The device displays its name VT110 or VT115 then the measured values gt Put the probe to the required location The device displays the measurements of velocity or airflow and of temperature Sanciivecienent a element velocity Gensiiva clement Pe element velocity temperature temperature Ss g Protective tube of the sensitive element 1 ions lt Tube de protection de l l ment sensible 1 lt White point Xn lt Red point Bottom of the Bottom of the telescopic landmark hotwire probe landmark hotwire probe VT110 Standard hotwire probe VT115 Telescopic hotwire probe Airflow direction Airflow direction e Before any device usage with the standard or telescopic hotwire probe standard please lower the protective tube 1 of the sensitive element A e Always use the hotwire probe with the red point in front of the flow e Always use the telescopic hotwire probe with the white point in front of the flow PERFORM AN AVERAGE IN VELOCITY During a measurement gt v v v Vv Press on OK Start
6. low mode gt Press on Select until UNIT blinks on screen with the airflow unit displayed below gt Press on OK The unit currently used blinks on screen gt Press on Select to select the required measuring unit m h L s fem or m s gt Press on OK to validate UNIT blinks on screen gt Press on On Off Esc to return to the measurement display EL UNIT 0 UNIT Steet SEL m3 h m3 h SE x SE Se EL m3 h L s Select the measuring unit in temperature The device is on and displays the measurements gt Press on Select until UNIT blinks on screen with the temperature unit displayed below gt Press on OK The unit currently used blinks on screen gt Press on Select pour choisir l unit de mesure souhait e C F gt Appuyer sur la touche OK pour valider UNITE clignote a l cran gt Appuyer sur la touche On Off Esc pour revenir a la mesure EL S nlala lO O oC a L e Seca m s EL UNIT os F 0 L UNIT p L s 25 4 L s C Adjust the auto shut off The device is on and displays the measurements gt Press on Select until AUTO OFF blinks on screen gt Press on OK The time before device auto shut off blinks on screen gt Press on Select to select the time before device auto shut off 15
7. splay DISPLAY THE MINIMUM AND THE MAXIMUM Once the measurement is frozen gt Press on Hold min max The device displays the maximum value of velocity or airflow measured since the last questioning at the top of the screen and the minimum value of velocity or airflow measured since the last questioning at the bottom of the screen Press on Hold min max The device displays the maximum value of temperature measured since the last questioning at the top of the screen and the minimum value of temperature since the last questioning at the bottom of the screen Press on On Off Esc to return to the measurements display ADJUST THE DEVICE e Device drop down menu SEL SEL SEL SE 1x eet gt MODE 2x sate UNIT 3x Stee UNIT 4x 60 AUTO OFF VIT we Km h Select the measuring unit in velocity The device is on and in velocity mode gt Press on Select MODE blinks on screen gt Press again on Select UNIT blinks on screen gt Press on OK the measuring unit currently used blinks at the bottom of the screen then press on Select to select the required measuring unit fom km h m s gt Press on OK to validate UNIT blinks on screen gt Press on On Off Esc to return to the measurement display UNIT UNIT UNIT se Get se Km h Kmlh m s Select the measuring unit in airflow The device is on and in airf
Download Pdf Manuals
Related Search
Related Contents
Mairie Gare Église La Rive Les Échalières Perrières Bascule SUNNY WEBBOX with Bluetooth® Wireless Technology Samsung SCX-4016 manual de utilizador 座注 意(ちゅうい) User Manual for ArcGIS Online THE SWAM USER MANUAL IN A NUTSHELL. Benutzung Reflections TA Mode Emploi 2011 V1.0 Severin WK 3338 electrical kettle Transcend 1GB SDRAM PC133 ECC Registered Memory Copyright © All rights reserved.