1. TechGrow T 2 User manual The Quick menu s The Quick menus give a compact overview of all settings You do not have to go through all the menu s to see how your adjustments are set The Quick menu s can only be reached from the main menu Rotate the PTB for at least 10 clicks within 1 second to left or right That is turn the PTB quite fast Turn right First an overview of the set values and the hysteresis of CO2 TMP and RH will be shown photo20 CO2 SET 850 40 TMP SET 29 2 RH SET 65 3 Push Exit Turn the PTB 1 click to the right to see all Min values photo 21 e CO2 MIN 583 ppm TMP MIN 26 C RH MIN 50 Push Exit Turn the PTB another click to the right to see all Max values photo 22 e CO2 MAX 1233 ppm TMP MAX 32 C RH MAX 69 Push Exit Turn the PTB another click to the right to see all Box settings photo 23 BOX perc 20 BOX A M Auto Auto MAX 90 Push Exit 21 TechGrow T 2 User manual With another click to the right you will return to Set values by turning left you will return to the Max values This way it becomes possible to go through the quick menu s By pushing the PTB you will return to the main menu If you do not change anything the T 2 will return to the quick menu after 30 seconds Turn left Gives the same overview as turning to the right only now sorted by the same measurement value
2. The following will appear on the display for 3 seconds photo 6 e The box is now e adjusted TechGrow T 2 User manual When you are using a Torin or Lemmens fan The Brand menu photo 7 Lemmens Torin Custom Push or wait Select your brand then select your fan photo 8 Select fan 2500 m3 Push or wait 3 seconds By rotating the PTB the desired fan can be selected After a push on the button the selected fan will be set as standard When restarting the T 2 this fan setting will be used as standard If you do not change anything the T 2 will proceed after 3 seconds using the previous fan setting Options are from 1000 5000 m3 hour Next is the Calibration menu photo 9 CO2 calibration Continue Yes No This option is standard set at No If you do wish to calibrate the CO2 sensor please read the Calibration manual first Normally the sensor does not need calibration Only in exceptional cases calibration will be needed Wait for 3 seconds or press No to enter the main menu TechGrow T 2 User manual The previous menus are only accessible after powering up the T 2 Once the T 2 is in the main menu mode no access is possible to beforementioned menus To return to the main menu the T 2 has to be switched off for at least 20 seconds and then switched on again Main menu photo 10 e CO2 700 ppm e TMP 25 7 C e RH 62 e BOX 20
3. Manual Line 1 The current value of the CO2 level is displayed An asterisk means that the light is detected If the asterisk is not shown it means no light is detected Line 2 The current temperature Line 3 The current relative humidity Line 4 The current speed of the fan Next to it is the current state of the fan control To change the settings push the PTB and rotate until the arrow appears next to the desired submenu and push the PTB again to confirm If you do not change anything the arrow will disappear after 5 seconds and rotating the button will have no effect photo 11 TechGrow T 2 User manual CO2 menu photo 12 e CO2 set 700 ppm e CO2 50 ppm e CO2 ALARM gt gt NEXT gt gt Line 1 CO2 set A blinking square appears in front of the value of the CO2 set By rotating the button you can change the value range 300 2000 With a push on the PTB you confirm the value If you do not change anything the blinking square will disappear after 3 seconds and you will be able to make a different choice If you do nothing again the arrow will disappear after 3 seconds and you will return to the main menu Line 2 CO2 Operates the same as line 1 only for adjusting the hysteresis bandwidth The range is 10 200 Line 3 CO2 ALARM Here the alarm value for the CO2 level can be adjusted photo 13 e CO2 ALARM CO2 1500 ppm lt lt BACK lt lt When the alarm value is reach
4. photo 24 e CO2 SET 850 ppm e CO2 50 ppm e CQ2 ALM 1500 ppm e Push Exit Turn the PTB 1 click to the left photo 25 e TMP SET 29 C e TMP 2C e Push Exit Turn the PTB another click to the left photo 26 e RH SET 65 e RH 3 e Push Exit Turn the PTB another click to the left to go to Box menu photo 27 BOX perc 20 e BOX A M Auto Auto MAX 90 e Push Exit 24 TechGrow T 2 User manual ASSEMBLING THE MOUNTING BRACKETS CONTROLLER ce team santa io n 5 i f q sa CO2 SENSOR TECHNICAL SPECIFICATIONS Power supply 110 or 230 Volt automatic 50 60 Hz Consumption 3 Watt with sensor without CO2 bron Maximum power fan 1400 W max 6A Maximum capacity fan 5000 m3 hour Adjustment range CO2 set 300 to 2000 ppm Adjustment range CO2 10 to 200 ppm advice 50 ppm Measurement frequency 1 measurement per second 14 Pig amp Blay AEs ase ate external Mult Ser os Placable in any fo M leas oo Lil trical Timer 15 WWW TECHGROW NL TechGrow T 1 amp T 2 CO Sensor CALIBRATION PROCEDURE V gt i F F a z pe al gt Z D gt m TechGrow CO Sensor calibration procedure The TechGrow T 1 and T2 controllers come with a unique calibration feature that allows you to calibrate the device in case of large deviation Only calibrate the sensor if you suspect a
5. deviation Experience has shown that the Sen seAir sensors we use function without any problems for at least two years without calibration being necessary The sensors are calibrated with the highest precision during manufacture however it could occur after a year in use that the sensor shows a deviation and needs to be calibrated PREPARATION FOR CALIBRATION 1 Place the CO2 sensor in a CO2 neutral environment such as a balcony or your garden for at least half an hour or in a sealed and well ventilated room for at least 8 hours This is best done during daytime because the CO2 values will be closest to 400 ppm During nighttime plants and trees emit CO2 and the outdoor CO2 values will be closer to 450 ppm If the minimal value is not much lower than 370 ppm or much higher than 430 ppm it is not nec essary to calibrate the sensor That is because the value of neutral clean outdoor air is between 380 ppm and 420 ppm A devi ation of 5 is common with this type of measurement equipment Please keep this in mind when setting your CO2 values In case of a greater deviation calibration is necessary Please continue with step 2 2 To calibrate the sensor you have to switch DIP switch 1 see image from position 0 to position 1 ON This is to prevent any unintentional calibration caused by any electronic dimmable control gear which can cause much disturbance to our measurement equipment This manual security has been built in f
6. WWW TECHGROW NL TechGrow T 2 to mere pp ie EBJ i gt vith pond coz sensor temperature sensor i Te ej umidity_ s sensor and Calibration function Software version 1 60 D Z gt m Issued 01 11 2014 TechGrow T 2 User manual A full climate controller with a revolutionary fan control that responds to all TechGrow sensors oe FEATURES Plug amp Play can be used in small to very large rooms e Extremely accurate external CO2 sensor produced by SenseAir Sweden for CO2 measurement and Sensirion Switserland for temperature and humidity e Calibration function for CO2 and temperature e CO2 adjustable between 300 2000 ppm e The sensor takes a measurement every second e LED indicates when CO2 is being dosed e Measures CO2 temperature humidity and light simultaneously e Regulates CO2 and humidity during the night e Switches the CO2 source CO2 generator CO2 cilinder on off using a 230V relay e Memory in case of power outages for setpoint and hysteresis e Suitable to connect fans up to 5000m3 hr e All set hysteresis and alarm values of the sensors are separately adjustable e Shortcut menu for a quick summary of all settings e The fan control has 2 adjustment settings automatic and manual e The fan control is adjustable in steps of 10 for all fans pre programmed for Torin and Lemmens fans e The external CO2 sensor has a built in light sensor to automatic
7. ally switch between day and night settings e Automatically detects broken cable or bad connection of the connected sensors e Connecting the sensor is done with a standard network cable UTP Included are 2 cables of 5 meter each e Possibility to connect the TechGrow AM T a SMS module to remotely read values from your CO2 controller INSTALLATION 1 It is recommended to mount the CO2 sensor on a wall close to the CO2 source with a minimum distance of 50 cm It is not advisable to place the sensor directly over the CO2 source if that source can reach very ea Sa high temperatures CO2 generator The sensor must be placed F approximately 1 meter above the floor For this use the enclosed mounting bracket 2 It is not recommended to mount the Temp RH sensor in such a way that it catches full light The housing of the sensor can reach high temperatures and wrong values could be shown The sensor must be placed approximately 1 meter above the floor For this use the enclosed mounting bracket TechGrow T 2 User manual ATTENTION please make sure that the light sensor the milk coloured cap on top of the CO2 sensor can absorb light directly and is not obstructed by e g shelves or fixings as then it will not be able to differentiate between day and night 3 Mount the TechGrow T 2 controller to the wall with the supplied mounting bracket 4 Connect the sensors to the TechGrow T 2 controller with the supplied UTP cabl
8. anol depending on software version e Francais By rotating the Push amp Turn Button PTB the desired language can be selected After a push on this button this language will be set as standard value When restarting de T 2 the selected language will be used If you do not change anything the T 2 will proceed after 3 seconds using the previous language Factory setting Dutch Brand menu photo 3 e Lemmens Torin e Custom Push or wait You can select the desired extractor manufacturer by moving the arrow with the PTB With a push on the button you confirm your selection You will then go to the Fan menu automatically see later on If you are using another brand than Lemmens or Torin please choose Custom and push the button photo 3 To return to the main menu the T 2 has to be switched off for at least 10 seconds Then switch T 2 back on TechGrow T 2 User manual Custom menu photo 4 e Adjust the box at 10 e and push the button e See manual The fan is now switched off Slowly turn the PTB until the fan has reached 10 of its maximum speed according to your sense Push the PTB again The following will appear on the display photo 5 e Set the box at 90 e and push the button e See manual The fan is now rotating slowly Turn the PTB slowly until the fan s speed is no longer increasing This is the full 100 speed Now turn the PTB back to 90 according to your sense Push the button to confirm
9. ed the fan will rotate faster until auto max position Line 4 gt gt NEXT gt gt Here you can find the minimum and maximum values of the CO2 value photo 14 e CO2 Min 496 ppm CO2 Max 981 ppm Reset Min Max lt lt BACK lt lt To set the Min or Max value at the current CO2 value select by rotating the PTB then push Select lt lt BACK lt lt to return to the main menu 12 13 14 TechGrow T 2 User manual TMP menu photo 15 TMP set 30 C TMP 1 5 C TMP Corr 0 4 C gt gt NEXT gt gt Line 1 Here you can adjust the desired temperature Line 2 Here you can adjust the bandwith HYSTERESIS Line 3 Although the temperature sensor is very accurate it can be desirable to have the indication equal to other measurement equipment By using TMP Corr you can adjust the indication in steps of 0 1 C from 5 0 C up to 5 0 C Line 4 gt gt NEXT gt gt Min Max menu photo 16 TMP Min 26 C TMP Max 33 C Reset Min Max lt lt BACK lt lt Select and push to set the Min or Max value to the current temperature Select lt lt BACK lt lt to return to the main menu TechGrow T 2 User manual RH menu photo 17 RH set 50 RH 3 e gt gt NEXT gt gt Line 1 Here you can adjust the desired humidity value Line 2 Here you can adjust the desired bandwith HYSTERESIS Line 3 gt gt NEXT gt gt Go to M
10. es 5 Plug the CO2 source into the socket of the TechGrow T 2 controller 6 Plug the fan in to the socket of the TechGrow T 2 controller 7 Plug the TechGrow T 2 controller in a 230V socket 8 Ready OPERATING THE TECHGROW T 2 CO2 CONTROLLER When the CO2 value in a room drops below the set value setpoint the CO2 source will be activated After a while the CO2 value will rise and when it has reached the CO2 set value the CO2 source will be deactivated again EXAMPLE The CO2 set is at 670 The CO2 is at 40 The current CO2 value in the room is for example 733 which is higher than the CO2 set so the CO2 source is deactivated The red light is now turned off The CO2 gradually starts to drop to 670 still nothing happens Only when the value drops below the CO2 set minus the CO2 which in this case is at 670 40 630 the CO2 source will be activated and the red light turns on The CO2 is now rising and as soon as the value of 670 has been reached the CO2 source will be deactivated again By adjusting the CO2 a stable atmosphere can be obtained Factory settings the CO2 is set at 700 ppm the CO2 is set at 50 TechGrow T 2 User manual When activating the T 2 the following will appear on the display sequentially foto 1 e TechGrow T 2 e Software v 1 60 After 3 seconds a menu will appear to select the desired language photo 2 e English e Nederlands e Deutsch or Esp
11. in Max menu photo 18 e RH Min 50 e RH Max 62 e Reset Min Max e lt lt BACK lt lt TechGrow T 2 User manual sania nenn photo 19 BOX perc 20 BOX A M Manual Auto MAX 90 e lt lt BACK lt lt Line 1 Here you can set the idle power of the fan If all measured values are normal the fan will operate at this speed Line 2 Here you can select Automatic or Manual control of the fan In Auto the fan will rotate faster automatically if a measured value is too high That is if the CO2 is higher than CO2 set CO2 or if TMP is higher than TMP set TMP or if RH is higher than RH set RH Every 5 seconds the fan will soeed up 10 until the value AutoMax has been reached If the measured values are normal again the fan will automatically rotate slower until the inactive percentage has been reached NOTE the Auto adjustment only responds to CO2 if the lights are turned off When the lights are turned on the Auto adjustment will not respond to the CO2 However for TMP and RH the Auto adjustment functions all the time In Manual mode the fan will always rotate according to BOXperc speed Only when the CO2 alarm value is exceeded the fan will rotate faster until AutoMax has been reached This will occur either with the lights turned on or off Line 3 Adjustment of the maximum fan speed in Auto see Line 2 Line 4 Return to main menu 11
12. or exactly that reason 3 Open the sensor case 4 screws see image A 4 Locate DIP switch 1 see image B 5 Switch DIP switch 1 to position 1 ON using a pen or a small screwdriver image C 6 The sensor can now be calibrated 2 17 image A image B image C CALIBRATION MENU 1 2 3 4 Disconnect the power supply to the T 1 T 2 CO2 controller Re connect the power after 20 seconds The display will first show the type and software version of the controller Next a language menu is shown photo 1 after 5 seconds the question appears to continue cal ibrating Choose Yes photo 2 If you do nothing or choose No the controller returns to the main menu without calibration CALIBRATION PROCEDURE The calibration menu guides you step by step through the procedure Note step 5 is your last chance to terminate the calibration and return to the main menu without mak ing any modifications 18 O APON CO2 calibration continue gt Yes No photo 2 Place DIP switch 1 to position 1 ON Consult the manual gt Continue photo 3 Place the sensor outside and wait 20 minutes gt Continue Stop photo 4 Start calibrating sensor at 400 ppm gt Yes No photo 5 IS THE SENSOR OUTSIDE gt Push button for 10 seconds to start calibration photo 6 Arrows gt will appear on the second line of the display If the button is released before the line is completel
13. y filled you will be returned to the main menu The sensor will not have been calibrated photo 7 Calibration is starting Ready in 20 minutes photo 8 During these 20 minutes a message will be displayed every 10 seconds Please stay away from the sensor Do not forget to switch back the DIP switchl Every minute an asterisk will appear on the last line of the display photo 9 8 After 20 minutes the message Calibration 400 OK will appear and the controller will 9 automatically return to the main menu photo 10 NOW YOU HAVE TO SWITCH DIP SWITCH 1 BACK TO POSITION 0 image B 10 Close the sensor case image A ET sort pp j Matas a tren y accurate CO sensor allest ofits kind BACKUP fOr Up to 24 nors Works with any 12 Volt car batte istallet tee alata ul es 20

Download Pdf Manuals

image

Related Search

Related Contents

ÄÞºñ ³ÃÀå°í(ºÒ)P3423-7 - DAEWOO Electronics France  LN-505/506/507/508/509 LN-515/516/517/518 - CD  Bedienungsanleitung  60 7 , 0 90 M T scopes  研究開発型町工場の飽くなき探求  Manual de Usuario Instalación y Uso de Realidad  manual de instrucciones lavavajillas whf085edhw  Ciclos de apalpação iTNC 530  Decreto 22 gennaio 2014 - Ministero dell`Ambiente    