Home

User Manual

image

Contents

1. 51 57 89 00 Fax 47 51 57 89 50 E mail info tranberg com www tranberg com Tranberg Systems Hjulmagervej 15C 7100 Vejle Denmark Tel 45 75 85 83 80 E mail mail amp tranbergsystems com www tranbergsystems com Tranberg AS P O Box 8033 N 4068 Stavanger Norway Tel 47 51 57 89 00 Fax 47 51 57 89 50 E mail infoGtranberg com www tranberg com Tranberg Systems Hjulmagervej 15C 7100 Vejle Denmark Tel 45 75 85 83 80 E mail mail amp tranbergsystems com www tranbergsystems com TRANBERG
2. TEF 9964 XENON HELIDEGK FLOODLIGHT INDUSTRY USER MANUAL IMPORTANT Read this instruction carefully before installing the product Ma J g b gol OP Q i SN NE SCS sa A O O 16 06 2015 TRANBERG Tranberg AS P O Box 8033 N 4068 Stavanger Norway Tel 47 51 57 89 00 Fax 47 51 57 89 50 E mail info tranberg com www tranberg com Tranberg Systems Hjulmagervej 15C 7100 Vejle Denmark Tel 45 75 85 83 80 E mail mail tranbergsystems com www tranbergsystems com TUM 1024 REV H TEF 9964 XENON HELIDEGK FLOODLIGHT INDUSTRY USER MANUAL INTRODUCTION TOOLS REQUIRED Thank you for purchasing this product Regular tools required for installation For installation maintenance and assurance of a long life of this product please follow this manual 17 mm wrench for assembling the floodlight e 13 mm wrench for adjusting the angle of the light e 8mm flat screwdriver for open closing the cover of the junction box e 3 mm flat screwdriver for installing the cable in the terminal block APPLICATIONS e 5 5 mm flat screwdriver for removing the lamp insert e Floodlighting of helicopter landing areas e 32mm wrench to assembly the cable gland e For use safe area e 30mm wrench to tigh
3. e gland gaskets as 1 The glass in front should face the centre at the helideck unless stated otherwise required to match the cable diameter Unused cable glands should always be replaced with a blind plug 2 Secure the floodlight to the helideck by means of four M10 bolts 4 Connect cables and replace the enclosure cover 5 Luminaire housing shall be connected to earth potential by groundwire of min crossection 2 5mm 14AWG i ry REPLACING XENON LIGHT BULB Warning High voltage components inside lamp Make sure to disconnect power before opening 1 REMOVE FRONT RING Loosen clamps and remove front ring Holding clip 3 Distance bracket 3 SLIDE OUT LAMP INSERT New version 2 REMOVE HOLDING CLIP AND OR DISTANCE BRACKET Old version 4A REMOVE LIGHT BULB NEW VERSION 4a 1 Disconnect the high voltage plug from the light bulb Position lamp removal tool over locking ring as shown below twist approx 30 degrees anti clockwise 4a 2 Remove xenon lamp Xenon lamp E Locking ring 5 INSERT NEW XENON BULB 4B REMOVE LIGHT BULB OLD VERSION 4b 1 Disassemble the reflector unit 3 x M4 screws D
4. isconnect the hight voltage plug 4b 2 Position lamp removal tool over locking ring as shown below Twist approx 30 degrees anti clockwise 4b 3 Remove xenon lamp Xenon lamp Locking ring Note make sure the new xenon bulb is clean Do not touch the glass part of the bulb Mount lamp back together in reversed order TEF 9964 XENON HELIDEGK FLOODLIGHT INDUSTRY USER MANUAL SPARE PARTS Part No Xenon Lamp D2S 35W For TEF 9964 9400074 Front Glass 3141 High Voltage Igniter Unit Xenon 9400103 Locknut for Xenon D2S 9400108 Transformer W Mounting Bracket for 9964 230 254 VAC 4386 Transformer W Mounting Bracket for 9964 110 VAC 4387 Rectifier For 9964 Xenon Helideck Light 3069 Cable Gland E704 3C M25 Cable diameter 8 5 13 5mm 13 17mm 9147200 Complete Insert for TEF 9964 230 254V Se Complete Insert for TEF 9964 110V 3249 Complete Insert for TEF 9964 24V 4210 Tool for Replacing Xenon Lamp in TEF 9964 Helideck Floodlight 4676 Tool for Helideck Lights 4627 TECHNICAL DATA Material Acid proof stainless steel Polycarbonate front glass Input voltage 230 254 VAC 50 60Hz 110 120 VAC 50 60Hz 24 VDC Power consumption 50Watt IP rating without drain plug IP 66 67 according to EN 60529 IP rating with drain plug IP 66 Cable glands 2 X M25 cable diam 8 5 13 5mm 13 0 17 0mm Area of use Safe area Weight 10 kg TRANBERG Tranberg AS P O Box 8033 N 4068 Stavanger Norway Tel 47
5. ten the lock nut and the pressure e Floodlighting nut CONTENT IN BOX The product is fully assembled and ready for installation MAINTENANCE INSTRUCTIONS The luminaire should be inspected according to Company routines The manufacturer suggests regular check for water intrusion condensation which should be removed immediately Check the drain plug drain hole function When cleaning use only mild detergents Alcohol or petroleum based products may damage lens paint or plastic components SAFETY PRECAUTIONS Note that changes made to the product and or installation of components which do not conform to the approval may be a safety violation The manufacturer will in no circumstance be held responsible for such activity For your health and safety always use safety gear suited for the task Be certain to follow codes regulations and or specific procedures that are related to the installation RUBBER SEAL Cable diameter Size Part No 8 5 13 5mm 223 13x8mm 5002 0124 13 17mm 223 16x8mm 5002 0125 Be sure to install the cable in a way wich prevents water to penetrate into the enclosure through the cable gland also make sure to use the correct rubber seal when you install the luminaire TEF 9964 XENON HELIDEGK FLOODLIGHT INDUSTRY USER MANUAL INSTALLATION INSTRUCTIONS The floodlight should be installed according to the calculated light distribution plan 3 Open the enclosure cover on rear Replace cabl