Home

Metal waterproof access control system User Manual

image

Contents

1. condition On Off On On Unlock Alarm Fast flashing a Exit Slow Off programming flash o owo Alarm sound 8 Installation method lead wire description and Cabling diagram 8 1 Installation method 8 1 1 On the wall of the aperture size machine on the pan is playing well with a hole or installed 2 exisiting junction box plus connecting Figure 1 Figure 8 1 2 Put the lead wire from Bottom shell of the outlet hole oout he connection of cable needed Unused lines wrapped with insulating tape isolated to prevent short circuit 8 1 3 Finish line Install the front cover to the back cover Finally tighten the screws Fixed the front cover and back cover 8 2 Lead wire description Line Marks Color Function description sequence e do Green WGoutputineDO 5 ALARM Grey Alarm negative alarm positive connected 12 v OPEN Yellow Exit button one end Exit button the other end connected GND 7 D_IN Brown Magnetic switch one end magnetic switch another end connected GND a DG 2v Red Power supply 9 28V input DC inputs 10 NO Relay normally on end Connected positive electric lock Relay Publicend Connected GND 12 NC Orange Relay Closedend connected negative electric lock 8 3 Cabling diagram 8 3 1 Ordinary power supply Cabling diagram JIT TOIJUOD SSII proMssedTe LO BELL_A Pink BELL_B Green D1 ALARM Gray OPEN D_IN Brown feefee E D co ta Wat
2. Metal waterproof access control system User Manual Reading carefully before Install and use this manual 1 Product Profile The product is Contact less inductive card Metal Password Access Controller According to the model respectively support EM HID MIFARE three cards Itis one of the most advanced stand alone access controller It uses unique metal exterior design Dexterity keyboard panel operation Built in high grade microprocessors Strong anti interference ability Safety and reliability is extremely high can provide a powerful security for 2 000 users It has strong functions such as low power consumption Luminous keyboard independent passwords wiegand output the output short circuit protection door magnetic alarm prevent demolition alarm exit button the doorbell interface level of security Settings etc widely used in home office residential area and other public places 2 Features Low power consumption less than 30mA standby current Luminous keyboard the night can also operate keyboard User capacity support 2 000 users Independent password can use password which irrelevant with the card to open the door User modification password Users can revise the door password Search speed charge to open the door time less than 0 1 S Output short circuit protection electric lock or alarm output circuit within 100 uS when shut down automatically output Wiegand output With Wiegand output interface Wg26 card number or W
3. g4 buttons output Usable keyboard delete card number After card is lost usable keyboard delete card Thoroughly eliminate safety lapses The demolition alarm Illegal dismantling machine built in alarm sound buzzer The bell button and interface key and circuit segregation external any the doorbell 3 Technical parameters Work Voltage DC9 28V Static Current lt 30mA Reading Range 3 8cm Capacity 2000 users Ambient Temperature 45 C 60 C Ambient Humidity 10 90 Electricity lock output lt 3A Alarm output lt 20A Output short circuit protection time lt 100uUS Open time 0 99 seconds adjustable Size 120 56 18mm 4 Administrator operation Restore factory settings Disconnect the power of the mechine press key at the same time conntect the power for it after the sound of beep then loosen key It means initialization of machine successfully Note restore factory Settings will not delete a user data Enter administrator operation status Press Administrator password Administrator the default password 999999 4 1 Modify administrator password Press 0 Note the administrator password for 6 8 random Numbers please take good care 4 2 Add user 4 2 1 Continuous increase card Press Reading card Reading card 4 2 2 Designated card No increase Press 1 Eight card number Eight card number Automatically increase the user ID automatically genera
4. het Blue EEE 1 ME a lock w 01 7U09 SSB00Y Door magnetic TE switch z Negative electronic E lock 5 p Figure 2 Ordinary power supply Cabling diagram 8 3 2 Access Control Power Supply Cabling diagram IJ OI U09 SS909E pPIOASSLATEJ N 28 rom Exit button Door magnetic e switch T 04 U09 SSoO0Y Positive electronic i lock j i Negative E el an n pn ic 7 V ACTOO QS SY Ss S usnd aNd AZT ON Woo ON Figure 3 Access Control Power Supply Cabling diagram 9 Packing list Metal waterproof access control 1 piee a a C Usermanual accesscontol 1 S S Tapping sorows 4mm2emm 4 Usedtor instalation fred Stopper m6mmx30 mm p 4 Used for installation fixed Star screws Used between the front cover and back cover for a fixed O3mmx6mm Warm Tip Please don t secretly repair machine if any problem please return to factory maintenance Before the installation on the wall if you want to punch please check carefully wiring or line tube prevent drilling broken wiring etc unnecessary trouble please use safe glasses when drilling or fixed line clip If product upgrades specifications will likely differ without prior notice
5. ities 4 7 2 1 If you open the door not closed properly 1 minute built in buzzer alarm tone hair tips door or turn off automatically after 1 minute 4 7 2 2 f normal unlock 20 seconds after the doors open or door is forced open external alarm and built in buzzer alarm at the same time 4 8 Security mode setting 4 8 1 Normal mode factory default Press 7 0 4 8 2 Lock mode Press That within ten minutes of continuous brush invalid card or enter the wrong password ten times external alarm and built in buzzer alarm at the same time 5 User operations 5 1 User use card modify password Press 5 2 User use ID No modify password Press Note applicable to a card or without card users if the user password is 1234 must use card to modify 5 3 Card open Reading card Effective namely open 5 4 Password open Press Password right namely open 5 5 Card Password open Reading card Card and password right namely open 6 Remove alarm operation 6 1 External alarm and built in buzzer alarm at the same time SwipelValid card or press Administrator password Can remove alarm 6 2 Close door alarm tips Close the door or swipe card Valid card or Input administrator password Can remove alarm 7 Acousto optic instructions Operation Red Green Buzzer Note Standby Slow Off jeasing o af Buttons oe DiDiDi Indicator is ba a i Success i a Failure Into programming Set
6. ted by this machine the range is 1 2000 and search from small to large 4 2 3 Designated ID No swipe card increase Press 4 2 4 Designated ID No and card No increase Press Note input ID digits for 1 4 digits The range is 1 2000 such as 1 01 001 0001 ID number all expressed 1 Add card user will automatically generate a default password 1234 but this password can t open the door only for a user to change a new password 4 2 5 Designated ID No and password increase Press T Note applicable to no card users password and card unrelated input digits for four but not for 1234 4 3 Delete user 4 3 1 Delete swipe card Press Reading card Reading card 4 3 2 Delete Designated card Number Press 2 Eight card number Eightcardnumber 4 3 3 Delete Designated ID Number Press z 4 3 4 Delete all Press 4 4 Door open method setting 4 4 1 Card open Press 3 0 4 4 2 Card Password open Press 4 4 3 Card or Password open Factory default Press 4 5 Unlock time setting Press Note The lock time range 0 to 99 seconds the factory default is 5 seconds 4 6 Alarm time setting Press Note The alarm time range 0 to 3 minutes the factory default is 1 minute 4 7 Magnetic Alarm Function setting 4 7 1 Shielding of the function factory default Press 6 0 4 7 2 Open the function Press 6 Open the function two possibil

Download Pdf Manuals

image

Related Search

Related Contents

Stovax 7008 Stove User Manual  VisualDSP++ 3.5 C/C++ Compiler and Library  Electrolux K 81200 i User's Manual  ダウンロード  PDF資料ダウンロード(3.7MB)      uC/Trace User`s Manual - Doc  Halo Lighting System L2756MB User's Manual  autorización de uso de maquinaria  

Copyright © All rights reserved.
Failed to retrieve file