Home
ms1 - Omni Controls
Contents
1. Humidity standards based on saturated salt solutions in plastic cylinders with a moisture permeable membrane Values 11 33 53 75 90 rh page 3 46 novasina Pre Arl oe eel eee 111 0534 ms1 basic set T 111 1564 Power supply 230V 111 1406 Power supply 115V 111 3542 Extension cable 111 0898 Surface temp sensor 111 0846 HOG 00 Extension at a 111 0826 PC interface Version 01 10 04 Measurement instrument ms1 Accessoirs F ms1 measurement instrument Basic set ms1 The portable ms1 measurement instrument is supplied in an impact resistant plastic case with two humidity standards The case also has space for further options including a power supply RS232 interface surface temperature sensor etc ms1 accessories 230V or 115V power supply The power supply is recommended when the ms1 is used for a long period in one place or to preserve battery power when the RS 232 interface is extensively used gt The ms1 does not recharge batteries If rechargeable batteries are used an external charger is needed Extension cable for ms 1 1 5m long cable with 9 pin plugs for remote measurements with the ms1 Use of the extension cable does not require recalibration of the instrument gt Recalibration is not necessary if an extension cable is used Surface temperature sensor A separate NTC temperature sensor for measuring surface temperatures of walls etc This plugs in t
2. 46
3. _ 111 1044 gt 111 1037 gt 111 1040 gt 111 1035 gt 111 1032 gt Prices see on the pricelist Version 01 10 04 11 rh 33 rh 53 rh 75 rh 90 rh 111 7847 Sensor check Set 111 7841 Empty case for set ms1 accessories Sensor Checks SC with European certificate Humidity standards based on saturated salt solutions in plastic cylinders with moisture permeable membranes Each salt is delivered in a well sealed box Sensor Checks SC are obtainable for the following values at 25 C 11 3 colour white 32 8 colour blue 52 9 colour green 75 3 colour purple 90 1 colour white ms1 certification in an accredited European laboratory A UKAS laboratory will certify the instrument at two or more humidity values and at several different temperatures if required Set with 5 Sensor Checks SC Humidity standards based on saturated salt solutions in plastic cylinders with moisture permeable membranes Each salt is delivered in a well sealed box Sensor Checks SC are obtainable for the following values at 25 C 11 3 colour white 32 8 colour blue 52 9 colour green 75 3 colour purple 90 1 colour white Catalogue AlR Novasina 2004 05 Internationally accredited laboratory All Novasina humidity standards can also be supplied with an internationally recognised certificate from an accredited European UKAS England Weight 90g Internationally accredited laborato
4. e electronics pharmaceutical chemical biology food preparation industries e Material humidity measurements in for example concrete wood paper and also in pharmaceuticals and chemicals Version 01 10 04 Catalogue AlR Novasina 2004 05 Measurement instrument ms1 A stand alone precision hand held instrument for relative humidity and temperature measurements in rooms air ducts and for material measurements non condensing with remote sensor 10 90 rh at 25 C and calibration at all 5 reference points Optional RS 232 interface for a printer controlled by the ms1 or PC software available the ms1 directly shows the relative humidity and the air temperature dry bulb temperature The built in processor also makes it possible to display the following Mollier diagram parameters e Wet bulb temperature Measurement instrument ms1 Dimensions 54x43x265mm Weight 280 g Power Battery 9V DC Humidity measurement Resistive electrolytic measurement cell Range 6 98 rh Repeatability 0 3 rh Precision 1 0 rh in temp range from 10 50 C and 10 90 rh Temperature measurement very precise NTC resistance Range 20 80 C Repeatability gt 0 1 C Precision 0 3 C Note Application and measurement range with the sensor mounted directly on the ms1 10 50 C With a remote sensor connected by an extension cable or tube 20 80 C Sensor Checks SC
5. ed salt solutions in plastic cylinders with moisture permeable membranes Each salt is delivered in a well sealed box Sensor Checks SC are obtainable for the following values at 25 C 11 3 colour white 32 8 colour blue 52 9 colour green 75 3 colour purple 90 1 colour white Catalogue AlIR Novasina 2004 05 ms7 printer system Portable smart printer system to connect the ms1 handheld instrument via an interface box directly with a standalone battery powered thermal transfer printer Other printers may be used Seiko printer Interface set Weight 280g 1m long printer cable D Sub 25 25 pin RS 232 interface box ms1 Seiko adapter box Adapter Interface Dimensions 60x40 x 20mm Weight 50g Adapter D Sub 25F 9M 25 in female connector 9 pin male connector Epson printer Interface set Printer cable is an flat cable Length 1m D Sub 25 25 pin connector ms1 RS 232 interface Epson adapter Weight 300g Thermal paper replacement Set of 5 rolls each 25 m long Weight 850 g Set Thermal paper for Seiko printer Models DPU 411 and 414 Paper width 11cm Humidity values in the temperature range 15 30 C E 11 3 rh SORT 32 4 rh FD oa 51 4 rh Oon 75 1 rh g0 or 89 9 rh The precision corresponds to the Greenspan Report 1977 typically 0 3 rh Weight 90g page 5 46 novasina Plog Bel ol ee ee Dee ee Eoi ma ma
6. ith the salt SC checks It ensures an airtight connection of a Sensor Check to the conical sensor gt Adapter CS only for the conical sensor gt Attach the adapter to the conical sensor first and then to the SC check Check that it is well sealed Adapter CS to conical sensor Dimensions 30x13 mm Material PE plastic Weight Og The adapter has no gasket on the sensor side The cone itself provides an airtight seal 111 1083 9V battery 111 1302 Styrofoam box for SC Version 01 10 04 9V battery Alkali manganese battery not rechargeable This battery permits up to 25 hours of continuous operation If a rechargeable battery is used an external charger is required The ms1 cannot perform this function Thermal insulation styrofoam box For the SC sensor Check system A styrofoam box providing optimal insulation and temperature stabilisation of a SC Check SC while calibrating the system Two half covers for simple temporary in situ mounting gt Can be used together with the SC calibration kit for optimal thermal protection during calibration Catalogue AlIR Novasina 2004 05 9V Battery for the ms7 Dimension 48x 25x 17mm Weight 50g Alkali cell battery Battery 9V DC 180mAh A standard battery available in most electronic shops Max storage time 2 years Styrofoam box for the SC check Dimensions 100x65 x50 mm Weight 10g Material thermal insulating styrofoam PPE page 9
7. novasina Plog Bel ol ee ee Dee ee mst Relative humidity 6 98 rh Temperature 10 50 C 20 80 C Precision 1 rh 0 3 C Communication Further parameters e Dewpoint e Mixing ratio e Specific enthalpy e Vapour pressure The ms1 humidity amp temperature measurement system Precise fast versatile A practical 1 000 times proven precision hand instrument for humidity and temperature measurements Thanks to its resistive electrolyte measurement principle the ms1 is particularly well suited to high precision humidity measurements in air and other gases Other special advantages are its robustness and long term stability as well as simple checking and recalibration functions using the Novasina Sensor Checks The sensor has outstanding repeatability Hysteresis is essentially not measurable The integrated computer makes it possible to display a number of Mollier h x Diagram parameters of particular importance to all climate and ventilation professionals The large clear multifunction LCD display has excellent contrast The instrument incorporates a shut down function to conserve battery power Other options include a power supply and an RS 232 interface to transmit data to a printer or PC software available Typical mS 1 applications e Heating ventilation and air conditioning e Room climate measurements in research and development laboratories e Local climate control in for example th
8. o the side of the ms1 and disables the built in temperature sensor of the ms1 Extension tube HOG 00 Fits the ms1 base instrument and enCK 3 sensor Connects the sensor to the ms1 for applications in air ducts and enclosures gt Use of the extension tube does not require recalibration of the instrument PC communication via RS232 RS232 interface 1m long cable software CD Including NOVALOG 32 for Win 9x 2000 NT Catalogue AIR Novasina 2004 05 Consisting of Carrying case with Measurement instrument ms1 9V battery Measurement cell enCK 3 Plastic rack for the ms Sensor Check SC 33 rh Sensor Check SC 75 rh Polystyrene box for calibration User manual Manufacturers procedure for the 5 point calibration 11 33 53 75 90 Weight instrument 220g Power supply 230V AC 10 50 60Hz 115V AC 5 50 60Hz Output 9VDC 16 mA Power requirement 0 4 VA Plug 4mm diameter coax Weight 250g Extension cable for ms1 Extension cable 1 5m 9 pin special connectors for ms1 and enCK 4 5 cell Weight 120g Surface temperature sensor Range 20 80 C Repeatability 0 1 C Precision 0 3 C Weight 70g Extension tube HOG 00 Length 240 mm Weight 110g Material Aluminium Polycarbon Interface Set comprising 1m cable with D Sub 25 25 pin RS 232 Interface Software CD with NOVALOG 32 for Windows systems User manual Weight 440g page 4 46 nova
9. olycarbonate rubber Weight 59 Tip to sensor SARK Material POM black Weight 5g page 7 46 ovasi g ric va aina Options ms1 kaa Replacement measurement cell CK 3 Humidity measurement cell CK 3 for the enSARK 3 enCSK 3 sensors oe l Humidity measurement e Humidity measurement without temperature sensor Range 6 95 rh H a or saturation protection 98 non condensing t Attention No saturation protection mia E ale by pts after a 7 el n E OBA G iter e Titer SUrTace on the top O e cell Snou Precision 2 0 rh not be touched Basis 5 Point cal with SC salts at 25 C Information recalibration of the ms1 at a minimum of two points Weight ake is required when a sensor is replaced High precision requires a 111 1013 CK 3 measurement cell 9 point Ca nian Set of 10 external tubes Set of 10 Precision tubes including cover plate for material Set of 10 precision reusable tubes with closing measurements caps for humidity measurements in concrete floors Weight 220g a set or walls using the enSARK 3 sensor The tubes are Application inserted in boreholes in the concrete floors or Make an opening in the wall floor walls The humidity is measured with a SARK Insert the tube sensor once a stable value has been reached Wait for the humidity to stabilise Measure the humidity using an 110 6562 Polycarbonate tubes ms1 and a SARK Sensor See also Set AM Conical sensor enCSK 3 Conical sen
10. ry Certified instruments can be supplied Case with all 5 Sensor Checks from 11 to 90 rh Humidity values in the temperature range 19 con 307C ere aan 11 3 rh SEO ean 32 4 rh IS 51 4 rh OO 75 1 rh 9o gin 89 9 rh The precision corresponds to the Greenspan Report 1977 typically 0 3 rh Weight 900g page 6 46 novasina Fim Mf ot ee ee eee 111 0978 enCk 3 R 1110985 Metal web eVMT 83 1112569 Sintered eVM 83I 111 6716 enSARK 110 7345 Adapter CH 111 6497 enSARK tip Version 01 10 04 Replacement parts Options to ms1 Replacement parts for the set ms1 Sensor enCK 3 Standard humidity sensor for the ms1 This sensor is mounted directly on the ms1 but can also be used with an extension cable or tube Information recalibration of the ms1 at a minimum of two points is required when a sensor is replaced High precision requires a 5 point recalibration Cell protection filters to enCK 3 sensors A number of filters are available to protect the measurement cell from abrasion or corrosive vapours gt Please consult the appropriate datasheets ms1 instrument options Sensor enSARK 3 with 2m connection cable and 9 pin plug A 13 mm diameter sensor rod with a duroplast tip CK 3 humidity measurement cell and NTC temperature sensor Designed for measurements in for example material in granulated form in sacks tanks and silos Sensor check adapter ch for any 13mm
11. sensor to SC check salt standard This adapter is needed for calibration an instrument It ensures an airtight connection of a Sensor Check to the sensor tube of the top of the instrument It reduces the diameter of 20 mm down to 13 mm and ensures an airtight seal gt The adaptor should first be attached to the sensor and then to the SC check Both seals should be carefully checked leaks will bias the calibration Replacement tip for Sensor enSARK 3 A hard plastic tip to ease the insertion of SARK sensors into materials gt Not usable with the older SARK sensors Catalogue AlR Novasina 2004 05 Sensor enCK 3 Dimensions 58 x 22mm Weight gt 10g Humidity measurement Range 6 95 rh Attention No saturation protection Repeatability lt 0 3 rh Precision 2 0 rh Basis 5 Point cal with SC salts at 25 C Temperature Measurement Range temp 20 80 C Repeatability 0 1 C Precision 0 3 C Metal web filter eVMT 83 to enCK 3 Dimensions 68 x 30 mm Effect mech protection against particles larger than 0 3 um Weight 40 g Sinter filter eVM 83I to enCK 3 Dimensions 55 x 30 mm Effectiveness mech protection against particles larger than 0 1 um Weight 90g See also Set AM Set and AMS Example humidity measurements of granulates sawdust or tobacco in a sack Weight 210g CH adapter for any 13mm sensors to SC checks Dimensions 30x13 mm Material P
12. sina Fim Mf ot ee eee eee 111 0562 Seiko interface 111 8426 Seiko Thermal paper 111 0885 gt 11 rh 111 0855 gt 33 rh 111 0857 gt 53 rh 111 0859 gt 75 rh 111 0896 gt 90 rh Version 01 10 04 Accessories for the ms1 ms1 local printer system Attention Any printer must be obtained locally Novasina does not supply printers RS232 interface for Seiko printer RS 232 interface 1m long cable to connect a Seiko DPU 411 thermal printer This makes it possible to control the printer using the printer parameters defined in the ms1 menu Attention The printer must be obtained locally Problems may arise with local language support D Sub adapter 25F 9M Adapter for the RS232 Interface for the Seiko printer 111 0562 permitting connection to the more recent Seiko DPU 414 printer RS232 interface for Epson printer RS 232 interface 1m long cable to connect an Epson or other compatible 9 pin needle printer This makes it possible to control the printer using the printer parameters defined in the ms1 menu Attention The printer must be obtained locally Problems may arise with local language support Thermal paper replacement rolls Printer type Seiko DPU 411 414 Attention This paper must be stored in a dark and dry place This is thermal transfer paper only intended for Seiko printers Note Set of 5 rolls each 25m long Sensor Checks SC Humidity standards based on saturat
13. sor to ms1 Dimensions 100 x 14 mm a Conical sensor for measurement in vats or directly Cable length 1m lt in materials Incorporates a sintered filter to protect Connector 9 pin plug for the ms1 instrument the measurement cell Incorporates a sintered Humidity cell CK 3 incl NTC filter for protection against fine dust and damage element for temp measurement Delivered with a 1m cable and 9 pin plug Range 6 95 rh 20 80 C 111 0852 Conical sensor See also ms1 set M Box sensor enMBRK 3 Box sensor enMBRK 3 incl Conical sensor enCSK 3 suji Cable length 1m A special sensor for humidity and water content Connector 9 pin plug for the ms1 measurements of large quantities of foodstuffs e g Weight 275g potato chips tea leaves granulates gt Includes the conical sensor enCSK 3 Nr 111 0852 111 0526 Box sensor enMBRK 3 ms i See also Set M Sintered filter Sintered filter for conical sensor a f MEER I i D 25x16 A i For the conical sensor enCSK 3 111 0852 and eile een m box sensor 111 0526 Material Sintered brass Attention carefully unscrew the conical sensor when changing l 111 1467 Sintered filter the filter Weight 30g Version 01 10 04 Catalogue AIR Novasina 2004 05 page 8 46 novasina Pte Srl el Fpl fe SSeS Options to ms1 111 1023 adapter CS Adapter CS for enCSK 3 sensor to SC check This adapter is needed for calibration of the enCSK sensor w