Home
PSAC 04244SEP
Contents
1. Pulsar PSAC 04244SEP v 1 0 PSAC 24VAC 4A 4x1A SEP AC power supply for CCTV EN Edition 1 from 06 12 2011 Replaces edition Hee C Features of the power supply unit e 4 independent galvanically separated outputs e protections e Voltage regulation by jumper e SCP short circuit protection e LED optical signalisation e overvoltage protection e AW technical output e overload OLP e against sabotage e OHP thermal protection of transformer CONTENTS 1 Technical description 1 1 General description 1 2 Block diagram 1 3 Description of elements and connectors of the power supply 1 4 Technical parameters 2 Installation 2 1 Requirements 2 2 Procedure of installation 3 Signalling the operation of power supply 3 1 Optical signalling 3 2 Technical output 4 Service and operation 4 1 Overload and short circuit 4 2 Maintenance 1 Technical description 1 1 General description AC AC PSAC 04244SEP power supply is using for supplying CCTV devices requiring AC voltage of 24 V with overall efficiency of 4A 24V AC The power supply is housed in a metal case colour RAL 9003 The casing is equipped with a micro switch that signals the opening of the doors front panel Information about additional elements of PSAC 04244SEP power supply module of the AC AC power supply in ABS casing MSC 1512 module of MSC 12V 1 5A or 24V 1A power supply exchanged voltage allowing to create a 24 V AC and 12
2. V DC 24 V DC supply system 1 2 Block diagram fig 1 OUTPUT4 TAMPER Fig 1 Block diagram of the power supply 1 3 Description of elements and connectors of the power supply table 1 table 2 fig 2 fig 4 Table 1 Terminal and elements of LB4 SEP Element No Description of LB4 SEP elements Fig 2 L1 L4 LED green signalling the status of L1 OUT1 output etc F1 F4 fuses in output circuits F1 OUT1 etc COM U1 U2 Input of the AC supply required transformer separation OUT1 OUT2 OUT3 OUT4 independently protected outputs Law LED red signalling failure of one of the outputs activation of a safety device AW output signalling failure of one of the outputs relay type Attention Fig 2 shows non potential state of relay i e the state of failure Jumper of the output voltage change independently for each output U2 Uf EN U2 jumper used voltage on OUTx U2 output U2 U1 HH U1 jumper used voltage on OUTx U1 output o A HE Jumper of the change in PTC fuse element safety device type FX FXX EN Fx jumper used fuse element protection device selected Fx FX x Fx x jumper used polymer protection device selected ii Uu ya INPUT 1 INPUT 2 INPUT 3 INPUT 4 E a i L4 B F 1 F 5 Bi a HN i luni ln wf Fx 2 Fs 2 F3 p3 n F4 exe s 4 ll ER 4 E PTC Fig 2 View of the LB4 SEP fuse block Table 1 Terminals and element
3. 0V AC installations and low voltage installations The device shall be mounted in closed rooms according to the environment class Il of the normal air humidity RH 90 max without condensation and the temperature within the range from 10 C to 40 C The power supply shall operate in a vertical position so that free and convectional air flow through ventilating holes of the casing is guaranteed Before installation is started the balance of the power supply load shall be performed During normal operation the sum of the currents consumed by the receivers cannot exceed I 4 0A 24 V AC Because the power supply is designed for a continuous operation and is not equipped with a power switch therefore an appropriate overload protection in the power supply circuit shall be guaranteed Moreover the user shall be informed about the method of isolation of the power supply from the power voltage usually through assignment and marking of an appropriate fuse in the fuse box The electrical system shall be made in accordance with valid standards and regulations 2 2 Procedure of installation 1 Before initiating the installation it is necessary to ensure that the voltage in the 230 V power circuit is disconnected 2 Mount the power supply in the selected place and guide connecting conductors 3 Connect the power cables 230 V AC with L N power supply terminals Connect the earth conductor to the clamp marked with earthing symbol The connection sho
4. 2 In case when there is no bill of sale when filing the claim three year warranty period shall be counted from the date when the device was manufactured 3 Warranty shall cover free repair or provision of functional equivalent the producer shall select the equivalent of the faulty device due to reasons lying in the domain of the producer including production and material faults unless these faults have been filed within the warranty period point 1 and 2 4 Device falling under warranty period should be delivered to the point where it was purchased or directly to the seat of the producer 5 Warranty covers complete devices with written description of the fault on properly filled claim application form 6 When a claim shall be positively considered the Producer shall be obliged to realise warranty repairs in the shortest possible time however this period of time should not extend 14 working days from the date when the device was delivered to the producer s service point T Repair period of which mention has been made in point 5 may be prolonged in case of lack of technical possibilities to perform the repair and in case of device conditionally accepted to the service point as the claimant did not meet the warranty conditions 8 All service activities resulting from the warranty shall be performed solely within the service point of the producer 9 Warranty does not cover faults of the device resulting from reasons not lying within the pow
5. ED L1 L4 green status of OUT1 OUT4 normal status illuminated failure status not illuminated LED Law red failure signalling of min one output normal status not illuminated failure status illuminated Fmainf use T 14 250 V F1 F4 fuses F 1A 250 V lub PTC 1A Mechanical parameters table 4 215 x 246 x 64 210 x 241 x 5648 WxHxD 178 x211 4x 66 Connections Supply 00 63 72 50 AWG 22 10 Outputs 00 41 71 63 AWG 26 14 TAMPER output cables 30cm The casing is equipped with distance from the mounting basis in order to guide the wiring system convection cooling User safety table5 PN EN 60950 1 2007 protection class first PN EN 60529 2002 U protection degree IP20 Insulation electric strength between the input network circuit and output circuits of the power supply I P O P 3000 V AC min between the input circuit and the PE protective circuit I P FG 1500 V AC min between the output circuit and the PE protective circuit O P FG 900 V AC min Insulation strength between the input circuit and the output or protective circuit 100 MO 500 V DC Operating parameters table 6 Operating temperature 10 C 40 C Storing temperature 20 C 60 C 6 2 Installation 2 1 Requirements AC AC power supply shall be mounted by the qualified installer having appropriate required and necessary for a given country permissions and qualifications for connecting operating 23
6. er of the producer mechanical failures improper storage and transport usage not compliant with the user manual or the anticipated use of the device random events including atmospheric discharges power line failure fire flooding influence of high temperatures and chemical agents improper installation and set up not compliant with principles included in the user manual 10 Statement of performing changes in construction or repairs performed outside the service point of the producer or when the serial numbers or warranty stickers on the device were anyhow damaged shall result in the loss of warranty rights 11 Responsibility of the producer towards the purchaser shall limit to the value of the device settled according to the determined wholesale price suggested by the producer from the date of purchase 12 Producer shall bear no responsibility for faults resulting from damaging improper activity or impossibility to use the device especially when the above results from non observance of recommendations and requirements included in the user manual or use of the device Pulsar K Bogusz Sp j Siedlec 150 32 744 tapczyca Poland Tel 48 14 610 19 40 Fax 48 14 610 19 50 e mail biuro pulsar pl sales pulsar pl http www pulsar pl
7. r supply is equipped with optical signalling the status of operation Presence of voltage on power supply outputs is signalled by illumination of green LED diodes on the plate of LB4 SEP fuse block Failure is signalled by red LED diode AW Condition of the power supply may be controlled remotely by AW technical output 3 1 Optical signalling e LED L1 L4 green signal the supply status on OUT1 OUT4 outputs In case of loss of voltage on the output burnout of the fuse activation of the PTC appropriate LED diode stops to be illuminated L1 for OUT1 L2 for OUT2 etc e LED AW red indicates failure of at least one output number of the output is signalled by the green LED L1 L4 3 2 Technical outputs The power supply is equipped with signalling output enabling to submit information about the failure or sabotage e AW relay type output signalling the activity of one of the output fuse Attention Fig 2 shows non potential state of relay i e the state of failure e TAMPER output signalling opening of the power supply casing output of the potential free contact signaling the status of the power supply doors power supply closed NC power supply open NO 4 Service and operation 4 1 Overload and short circuit of the power supply output Outputs OUT1 OUT4 of the power supply are protected against short circuits with fuse element safety device inserts or PTC In case of damaging fuse element safety device it is necessary
8. s of PSAC 04244SEP Element No Description of power supply elements 1 Separating transformer 2 Fuse block LB4 SEP tab 1 3 TAMPER anti sabotage protection contact NC HM y Fmain fuse in supply circuit 230 V AC PE protection connection Fig 3 View of the power supply panel 4 O6mm 246 mm 14 mm E co OIOI s m o ps3 VX 53 cs psa Wa e oun Hi n in M z CO N gt 211 mm Fig 4 View of the power supply 9 1 4 Technical parameters electrical parameters table 3 mechanical parameters table 4 user safety table 5 Operation parameters table 6 Electrical parameters table 3 U1 23 0 28 0 V AC 100 load 0 load U2 25 5 31 5 V AC 100 load 0 load 23 A 27 V AC max 4x F 1 0A fuse element or PTC 1A Short circuit protection SCP failure of the fuse element safety device requires changing the fuse element insert AC 24 V circuit 4x F 1 0A or PTC 1A changed by jumper AC 230V circuit 1x T 1 0A Overloading protection OLP Technical outputs AW output signalling failure of one of the relay type 1A 30V DC 50V AC max AUX outputs activation of the safety device Attention Fig 2 shows non potential state of relay i e the state of failure TAMPER output signalling opening of the microswitch NC connectors closed casing power supply casing 0 5A 50 V DC max Optical signalling L
9. to exchange the fuse compliant with the original If PTC polymer fuses protection was chosen then automatic disconnection of the output voltage was signalled by switching off the green diode It is then necessary to disconnect the load from the power supply output for the period of about 1 min Loading the power supply with the current exceeding 24 0A 24 V AC 110 150 of the S power results in the failure of the Fuman fuse in the 230 V AC circuit and or F1 F4 fuses In case of failure it is essential to exchange the fuse compliant with original 4 2 Maintenance All maintenance procedure may be performed after disconnecting the power supply from the power network The power supply unit does not require performing any special maintenance procedures however in case of significant drop of the dustiness it is only essential to remove the dust from the interior with the help of compressed air In case of changing the fuse it is essential to use substitutes compliant with the original parts recommended WEEE MARKING The used electric and electronic device may not be thrown out together with common household wastes According to WEEE directive binding within the EU in case of used electric and electronic devices separate means of utilization should be utilized GENERAL WARRANTY CONDITIONS 1 Pulsar K Bogusz Sp j producer provides two year quality warranty for the device counting from the date of sale indicated on the bill of sale
10. uld be performed with 3 core cable with yellow green PE protecting conductor Power conductors should be connected to proper terminals through seal wire The circuit of the shock protection shall be performed with a particular care i e the yellow and green protection wire of the power cable shall be connected from one side to the terminal marked by the symbol of inthe casing of the power supply Operation of the power supply without the properly made and fully operational circuit of the shock protection is UNACCEPTABLE It can result in failure of devices and electric shock 4 Connect the cables of consumers to the OUT1 OUT4 terminals on LB4 SEP fuse block 5 If necessary connect device cables alarm unit controller signaller etc to technical outputs of the power supply AW output signalling the activity of the fuse output of the LB4 SEP fuse block TAMPER output signalling opening of the power supply casing 6 In case of installation where significant drops in voltage in effective resistance of receiver supply cables can occur it is possible to correct the value of output voltage with the help of U1 U2 jumper independently for each output 7 Connect 230 V AC supply 8 Check optical signalling of the power supply operation LED L1 L4 green should be constantly illuminated 9 Close the casing after installing and verifying the correctness of the power supply activity 3 Signalling the operation of power supply The powe
Download Pdf Manuals
Related Search
Related Contents
GE LineFit Light LED System Installation Guide USER GUIDE - Allen & Heath MORIWAKI ZERO TEAR DROP ANO/WT SLIP Guida per l`utente Zebra GX420d™ / GX430d™ QUITA-POLVO L-31 その10(488KB) Volvo XC90 D Montage- und Betriebsanleitung Návod k montáži a GUÍA TÉCNICA ADJUNT A - Artículos para el jardín, piscina, SPA `-“wI5T Chopper“ - Clearpoint Direct User Manual 2 Copyright © All rights reserved.