Home
User Manual
Contents
1. Accessories Do not use any unsupported accessories as these may be hazardous or cause damage the product Location e Setup the device only in dry and dust protected rooms e Do not place the device near a radiator or heat register e Setup the device only in areas with the advised operating temperatures of 10 50 C 14 Warnings Follow all safety and operating advises before starting up the device 1 Follow these directions in order to avoid damage of the power cord or plug e Do not modify or process the power cord or plug arbitrarily e Make sure to disconnect the power cord holding the plug e Keep heating appliances as far as possible from the power cord in order to prevent the cover vinyl from melting 2 Follow these directions Failure to follow any of them may cause electrical shock e Do not open the main body or the power supply e Do not insert metal or inflammable objects inside the product e In order to avoid any damage during lighting use a surge protection 3 Do not use the product when it is out of order If you continue to use the product when defective serious damage can be caused to it Make sure to contact your local product distributor if the product is out of order AN During the installation into an existing video surveillance system make sure that all devices are disconnected from the low and supply voltage circuit If in doubt allow a professional electrician to mount install and wire up your de
2. Icon explanation A flash in the triangle is used if there is danger for the health e g by an electric shock An exclamation mark in the triangle points to an important note in this user manual which must be minded This symbol can be found when you are to be given tips and information on operation Important safety advice The warranty will expire for damage due to non compliance with these operating instructions ABUS will not be liable for any consequential loss ABUS will not accept liability for damage to property or personal injury caused by incorrect handling or non compliance with the safety instructions In such cases the warranty will expire The device has been manufactured in compliance with international safety standards Please read these safety advices carefully Safety advice 1 Mains supply 100 240V AC 50 60 Hz Operate this product only from the type of power supply indicated on the marking label If you are not sure of the type of power supplied to your home consult your local power company Disconnect the product from the mains before you start any maintenance or installation procedures Overloading Do not overload a wall outlet extension cord or adapter as this may result in electric fire or shock Liquids Protect the device from any kind of liquids entering Cleaning Disconnect the product from the wall outlet before cleaning Use a light damp cloth no solvents to dust the product
3. 2A Powersupply 12 VDC 2A DC 5 5 x 2 1 mm RJ 45 socket for connection to the IP network device For changes to device settings Device status display Connection for data transfer via coaxial cable 4 2 TVAC25110 connections Pw C ON DIP cpeco C see oo Power supply 12 VDC 2A DC 5 5 x 2 1 mm RJ 45 socket for connection to the IP network device For changes to device settings Device status display Connection for data transfer via a dual wire line 4 3 Housing backside On the rear side of the housing there is an optional earth connection for earthing the housing 18 5 Description of the DIP switches and status LEDs 5 1 DIP switches Master CPE Slave CO Signal to noise ratio DIP 1 Master Slave ON o PTET Use this switch position to connect the device to a PC ora postion aa router which accesses the network camera on the slave side Select this switch position to use the device on the network OFF position End device eee p DIP 2 Transmission ON iti Fast mod Use this setting to establish a fast data connection Please PaRa D observe that data loss could occur using this setting OFF iti ei q Use this setting if there is a high data rate and thereby avoid ical IAA any data loss on the transmission range DIP 3 Transmission rate ON Sp Unlimited Use this setting to utilise a maximum data connection with a Peston ened transmission rate of up to 100
4. MB s download 60 MB s upload Use this setting in the event that data losses occur on the ae 0 transmission line The transmission rate is then decreased to OE T Posen T Emea 50 MB s download 30 MB s upload in order to reduce the data loss DIP 4 Signal to noise ratio SNR ON J 6 dB Standard noise reduction which is used to compensate peer interference on the line Increased noise reduction the signal to noise ratio is increased in this mode This will be necessary in the event that OFF position 9 db increased data loss occurs on the wiring section The maximum transmission path is then reduced in this mode 19 These status LEDs on the network connection indicate the current connection status of the network componenis 5 2 Status LEDs o Status LED Bandwidth speed Flashing These status LEDs indicate the current connection status of the two devices O Pw cPE CO O LINK S Swienedon fst of CPE CO_ CPE Master _ J CO Slave _ _ LINK Connected Connection setup If the LED Link flashes rapidly the devices are attempting to set up a connection to each other If they flash slowly no connection has been set up 20 6 Installation 6 1 Installation set up On the device which is connected to the network camera first set DIP switch 1 to OFF Connect the IP camera and the device using a network cable Please only use the power supply units supplied for th
5. e installation of the devices Depending on the type of device now connect the two devices using a coaxial cable RG59 or a dual wire or telephone line twisted pair dual wire cable min AWG24 Warning Please observe that if coupled cables are used data loss could occur during transmission Dual wire cable connection set u Warning Please observe that connection could take up to 30 seconds 1 If the Link LEDs on both devices flash simultaneously a data connection is being set up 2 If both LINK LEDs light up continuously a connection has been successfully set up 21 Please observe that the data transmission rate depends on the length of the cable The longer the cable the lower the data transmission rate If cables have been spliced data loss could occur on the line 7 Data transmission rate The following bandwidths are available in Fast mode _ Distance Bandwidth Up to 100 MB s Up to 83 MB s 8 Maintenance and cleaning 8 1 Maintenance Regularly check the product s physical state e g check for damage of the housing If you suspect that safe operation cannot be guaranteed anymore disconnect the product and ensure that it cannot be used by mistake You can assume that safe operation is not possible anymore when e the device shows visible damage e the device does not function anymore Please note The product is maintenance free for you Inside the product are no parts
6. nnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nnmnnn nnmnnn nnmnnn nnmnnn nnmnnn 22 Gell E EEE E E A E S A A P E S I A E A 22 Oe AN ra E E E E E a eee E E 22 DISPOSE Aie enie cas nt ce wee los te wane alo EE ESEE sm a E RA EE TE Ea RA 22 Technical dala rn RS E EE 23 16 Intended use This transmission set IP via Coax or IP via dual wire is used for the transmission of network data via standard coaxial cables or twisted pair cables This allows IP data from network cameras to be transmitted easily using existing cables replacement with expensive network cables is therefore completely unnecessary You can also use this transmission set effectively at locations where a wireless connection is not possible or no WLAN is available A detailed description of all functions can be found in chapter 3 Features and functions Scope of delivery l Power supply incl Walls mount incl fixing Receiver amp Transceiver units EU AU and UK plugs Screws Features and functions e Use of existing BNC or dual wire lines for transmitting IP video signals e High bandwidth e Increased transmission distance up to 1500 m compared to network cables e Delay free real time video transmission e deal for transmission where radio transmission is not possible e Reduction of the installation costs since no cost intensive network cables must be installed 17 4 Physical descriptions 4 1 TVAC25100 connections ON DIP cpejco _ rot 12VDC
7. security Tech Germany TVAC25100 TVAC25110 User manual Version 11 2010 3 Original English user manual Keep for future use Introduction Dear Customer Thank you for purchasing this product This product meets the requirements of the applicable European and national guidelines The corresponding declarations and documents can be obtained from the manufacturer www abus sc com To maintain this condition and to ensure risk free operation you as the user must observe these operation instructions Before initial start up read through the complete operating instructions observing operating and safety instructions All company and product names mentioned in this document are registered trademarks All rights reserved If you have any questions please contact your installer or your local dealer A Disclaimer This user manual was prepared with greatest care If you should notice omissions or inaccuracies please inform us about these on the back of this manual given address The ABUS Security Center GmbH assumes no liability for technical and typographical faults and reserves the right to make at any time modifications to the product or user manual without a previous announcement The company is not liable or responsible for direct and indirect subsequent damages which are caused in connection with the equipment the performance and the use of this product No guarantee for the content of this document is taken
8. that can be checked or repaired so do not ever open it 8 2 Cleaning Wipe the product with a clean dry cloth If the device is very dirty you can moisten the cloth with lukewarm water Make sure that no liquids can enter the equipment as the device can be destroyed Never use chemical detergents as they could attack the surface of the device 9 Disposal Devices with this marking should not be put in the household garbage Dispose of the product at the end of its lifetime according to the applicable regulations 22 10 Technical data Model number TVAC25100 TVAC25110 RJ 45 DC input Earth connection Outputs BNC 75 Ohm Terminal for dual wire cable Type of cable Coaxial cable RG59 Dual wire cable ere CPE CO Master Slave LINK Data transmission Transmission rate distance Max 100 MB s 200 m Tarsmisson rale dslanoe Mac 2eMBe 1s00m O Dimensions W x H x D 136 mm x 30 mm x 95 mm Weight 315g 23
9. vice Improper electrical connection to the mains does not only represent at threat to you but also to other persons Wire up the entire system making sure that the mains and low voltage circuit remain separated and cannot come into contact with each other in normal use or due to any malfunctioning Unpacking While you are unpacking the device please handle it with utmost care A If you notice any damage of the original packaging please check at first the device If the device shows damages please contact your local dealer 15 Table of contents ee E 10 BTS IC SO A cee sets veces T OA A E T E E E E T 17 SCOPE Ol CONV CNY eni e E a a T 17 Features and fUNCHONS issan aa aaa a aaa a a a 17 Physical descriptions osen ie gcerey acces aana aaa aaa aaa aa a aaa aaa aaa Ean 18 4 1 TVYAC25100 CONMCCHONS eccacencanceccacptvewsncseciansccutntecsakutsccssatasinaseusdansacensivexsvebesqesssedeneodenceenueeaceseeden 18 42 TYAC25110 COMMCCUOINS sessen E a a aR R 18 4 3 Housing AC SIO sriisnssirrnnn E i aeee NE ETAR EEEE EREEREER AOSA 18 Description of the DIP switches and status LEDS cccccssseeseeeeeesseeeeseeenseeseeensseeeseoennseeseoenseees 19 oi DIF WC IO aE E E AE E E E eee E E 19 oa W LEDS saa E E E ee en ee eee ere nner 20 EEE a AEE AE E A E A AAN AA E AA A E A A E A E AE 21 CA HIS MAON OO UD sa E EA eras A EE 21 Dala rans mission Tale cosis a A a EEA 22 Maintenance and cleaning ssnsssnnnnnnnnnnnnnnnnnnnnnnn
Download Pdf Manuals
Related Search
Related Contents
StarTech.com 50 ft Straight Through Serial Parallel Cable - DB25 M/M dretec Email Usage Stats Collector 60 conseils pour une vie de famille et des relations harmonieuses Manuale dell`utente Read this first - Visual Artists Ireland Hitachi C 7YA Saw User Manual 減災miniSOHO カタログ 【Web版】 v.1.01 [100122] Eaton Basic ePDU IEC60309 4xBS 16A 3m Copyright © All rights reserved.
Failed to retrieve file