Home
TRACe B304-TR «
Contents
1. 53 SD DT G45 0e Page x Introduction TRACe B304 TR User s Manual Chapter 1 Introduction Kontron TRACe B304 TR is an EN50155 certified fanless Operational Computer designed to ensure stable ope ration in harsh environments This B version is specifically designed to ease customization thanks to MiniPCie slots and multiple configuration extentions to help integrators meet application specific requirements The B304 TR version is based on a CoM express CPU module featuring Intel Atom E3845 Bay Trail quad core 1 91 GHz Kontron COMe Intel Atom E3845 Bay Trail CPU http www kontron com products computeronmodules com express com express mini come mbt10 specification H 28 D 9 Figure 1 TRACe B304 TR Overview SD DT G45 0e Page 1 TRACe B304 TR User s Manual Introduction 1 1 Manual Overview 1 1 1 Objective This guide provides general information hardware instructions operating instructions and functional description of the TRACe B304 TR system The onboard programming onboard firmware and other software e g drivers and BSPs are described in detail in separate guides see section A 1 Associated Documentation This hardware technical documentation reflects the most recent version of the product Functional changes that differ from previous version of the document are identified by a vertical bar in the margin 1 1 2 Audience This manual is writte
2. 22 2 6 1 TRACE KIT CAB EVAL 22 2 099 2s ea he REX ARR ERRARE RR cR UR AUC ct 22 2 7 Plug and Play with TRACe B304 TR 23 PIU atem 23 2 5 2 tia vest eet cdi ocu Ba Saavik stood s date ote 25 2 8 Device Management 28 28 1 Powerstatus ERR MC ek Mado DE D epee E 28 SD DT G45 0e Page vi Table Of Contents TRACe B304 TR User s Manual 2 8 2 Status and User LEDs 1 28 28 37 Computer Reset xcci Sean ond de eee tad buat wee a 30 2 9 Health Management Unit Use Cases 31 29 1 2 92 0 554 edo een RC Rn 31 2 9 2 TRACe as a monitored Operational Computer 32 2 10 us REV NE ROREM NINE ERE RE na c MOM 33 2 11 Windows 34 Chapter 3 Deploying TRACe B304 TR 35 3 4 Installing
3. 35 3 1 1 Mounting Pre requisites 35 3 1 2 Physical ee 35 3 1 3 Physical Orientation 9 36 3 1 4 Horizontal Mount 9 36 3 1 5 Vertical Mount MAR 36 3 1 6 Thermal 2 37 3 1 7 38 3 1 8 Grounding Point Cabling 38 3 2 Servicing Preventive maintenance 40 3 3 Troubleshooting MRD eee 40 Chapter 4 Updating TRACe 7 41 4 1 BIOS eoi O o 41 4 1 1 Update BIOS from UEFI Shell using USB device 41 4 1 2 Record BIOS image ROM and setting from UEFI Shell using USB device 43 4 4 3 Default BIOS 44 42 CPLD gy VEI 44 421 cPLD SR ccc ene tenet n eee RRR 44 4 2 2 Default cPLD 5
4. 4 53 7 2 3 SATA Power Connectors 53 7 3 BIOS 54 TA CPLD dona dues 55 7 5 Management 1 56 7 5 1 Overview 56 7 52 Basic Commands 56 7 5 2 1 Inventory _ __ 56 7 5 22 EB TEES 57 7 5 2 3 Control Management VB 58 7 5 2 4 Alarm Management eee eee hh rns 58 7 6 Ge 59 7 6 1 BSP Contents REED 59 7 6 1 1 OS Release 59 7 6 1 2 COMeBSP ae 59 7 6 1 3 Specific Drivers CA EE 60 7 6 2 Network Configuration m 60 7 6 3 Tools 61 7 6 3 1 trace config TRACe Config
5. 4 CON con 52 4 isolated 1 05 serial DIO USB Eth mPCle mSATA GSM GMS R EON 3x mPCle slots WIFI MVB modules Figure 28 TRACe B304 TR Grounding SD DT G45 0e Page 39 B304 TR User s Manual Deploying TRACe B304 TR 3 2 Servicing Preventive maintenance In progress TRACe Health Management services will be made available with TRACe Operational Computers These services will provide information on the status of each TRACe in the field on line and through Internet to help user applications in supporting Spare part logistic management Fleet management gt Localization of failed equipment Preventive Maintenance Field servicing support gt Reliability analysis Acceptance Field test For now the HMU can already be used to get some useful information about the health status of the box Refer to chapter 2 8 Device Management page 28 2 9 Health Management Unit Use Cases page 31 and 7 5 Healh Management Unit page 56 for more information about HMU 3 3 Troubleshooting In progress TRACe Health Management services will be made available with TRACe Operational Computers These services will provide information on the status of each TRACe in the field on line and through Internet to help user applications in supporting Spare part logistic management Fleet management Localization of failed equipment
6. 44 4 3 Health Management Unit 45 4 3 1 Configuration for Updating HMU Firmware 45 44 47 Chapina WBling 48 Chapter6 Customizing B304 TR 49 49 6 2 tte arc etc d ant Stem 49 6 3 Plate scsi saciid donk ad weit ade ea ae area ae art 49 Chapter 7 Reference Information 50 TA Mechanical ayer ad sae CURES ated AERE PER eee seid PI Ee ER ses 51 7 1 1 Howto mount a SSD 51 Page vii SD DT G45 0e TRACe B304 TR User s Manual Table Of Contents 7 1 2 How to integrate mPCle 51 7 1 3 Assembly and Dismantling Instructions 51 7 2 Onboard Connectors ecce ach RAPI deh aware ach ah RENE ace i na de 52 7 2 1 MiniPCle Connectors 52 7 2 2 SATA DATA Connectors
7. Preventive Maintenance Field servicing support gt Reliability analysis Acceptance Field test For now the HMU can already be used to get some useful information about the health status of the box Refer to chapter 2 8 Device Management page 28 2 9 Health Management Unit Use Cases page 31 and 7 5 Healh Management Unit page 56 for more information about HMU SD DT G45 0e Page 40 TRACe B304 TR User s Manual Updating TRACe Chapter 4 Updating TRACe 4 1 BIOS 4 1 4 Update BIOS from UEFI Shell using USB device This section details the update procedure of the TRACe BIOS Firmware A USB key with the BIOS image to flash and the Firmware Update Utility will be used Last BIOS image and Firmware Update Utility are provided on EMD Customer Section of the COMe mBT10 on Kontron Web Site http emdcustomersection kontron com The Firmware Update Utility is included with the zip BIOS image file on Kontron Web site Before starting install the BIOS image to flash and the Firmware Update Utility on a USB key The USB key must be formatted in FAT32 VFAT or NTFS and shall contents gt MVV1Rxxx bin BIOS image to flash gt fparts txt gt fpt64 efi flash nsh Operating Mode Boot TRACe on UEFI shell If necessary enter the BIOS Boot Menu pressing F5 during the boot sequence Then navigate and select UEFI shell in Boot override menu and boot under UEFI shell Boot Menu App Menu eM
8. Maintenance Side View Rear View ____ L1 L2 L3 L4 L5 RST USBA 10 11 12 5 GPIO 4x inputs 4x outputs 6 Power status LED 7 Mechanical Ground YT SIM CARDS 13 14 15 Figure 3 TRACe B304 TR Rear View 8 Reset Button 9 Status and User LEDs L1 L5 10 UsB 2 0 11 Processor first serial line and HMU serial line RJ 12 12 DisplayPort 13 2x SIM Card Sockets 14 1x USB 3 0 USB2 port BIOS configurable 15 Gigabit Ethernet Port AX connector 11 is an RJ 12 connector on which two serial lines are available processor HMU You can get the compatible cable by purchasing our Cable Kit TRACE KIT CAB EVAL You can plug an RJ 11 cable in this RJ 12 connector to get the processor serial line TX RX GND If you use an RJ 12 cable make sure your cabling does not handle the pins allocated to the HMU serial line as flow control signals for the processor serial line to prevent conflitcts with the HMU If the HMU serial line is not needed and a custom RJ 12 cable is used it is recommended to leave the HMU serial line pins unconnected SD DT G45 0e Page 4 TRACe B304 TR User s Manual Introduction 1 2 4 Block Diagram PSU SATA 0 mCOMe SATA 1 W Processor Intel Atom WDG Ne MiniPCle MiniPCle MiniPCle 0 Full B MiniPCle 1 Full M MiniPCle 2 Full Size Size Size Display 0
9. Display 1 OPT Display DP Customizable plate SMA Video MVB USIM USIM Figure 4 TRACe B304 TR Block Diagram SD DT G45 0e Page 5 TRACe B304 TR User s Manual Introduction 1 3 Environmental Specifications gt ITE Safety Europe EMC Emission EN 60950 1 2006 A1 2010 A2 2013 EN 50155 A11 2009 A12 2011 NF EN50121 3 2 Safety Europe Directive EN 55011 Railway Safety Supply Voltage EMC Immunity EN 50155 2007 EN 50155 gt Railway NF EN50121 3 2 Thermal Operating EN 61000 4 2 EN 50155 EN 61000 4 3 NF EN 60068 2 1 2007 EN 61000 4 4 NF EN 60068 2 2 2007 EN 61000 4 5 Railway Class Tx EN 61000 4 6 gt Climatic Test Rail gt WEEE Directive 2002 96 EC Waste electrical and heat cyclic i amp heat cy electronic equipment EN 50155 NF EN 60068 2 30 2006 RoHS Directive 2002 95 EC Restriction of the use gt Railway of certain hazardous substances in electrical and s electronic equipment Random Vibration 7 gt Environmental Protection Operating Long life testing 50155 IP50 EN 60529 2000 61373 2011 04 60068 2 64 2008 gt Railway Class 1B gt Shock 9 IP50 for Maintenance side only with optional Cover EN 50155 Plate P N 01 NF EN 61373 2011 04 NF EN 60068 2 27 2009 Railway Class 1B SD DT G45
10. TRACe B304 TR User s Manual Getting Started with TRACe B304 TR Form Factor gt Dimensions Figure 6 TRACe B304 TR Dimensions gt Weight 2 5 kgs Warranty gt 2 years SD DT G45 0e Page 10 TRACe B304 TR User s Manual Getting Started with TRACe B304 TR 2 4 Operational Side Connectors Pinout 2 4 4 DC IN External PSU M12 Connector Male 4 Pin A coded View from Plug Side Figure 7 DC IN Connector Pin Configuration 1 VIN POWER IN VDC 2 VIN POWER IN GND 3 IGN Ignition IGN 4 NC NC Chassis SHLD Chassis ground Shield Table 2 DC IN Pin Configuration To power on the system you need a power cable with M12 Connector Female 4 Pin A Coded in one end see Appendix A Accessories References Examples pages 69 to find some references to fit the DC IN connector The power cable is included in TRACE KIT CAB EVAL cable kit to be purchased separately According to the above pinout free ends of this cable must be wired as follows refer to section 2 6 1 page 22 Brown VDC White VDC Blue IGN VDC to Power On IGN can be directly connected to VDC to have the system always on when VDC is applied or connected to VDC through a switch to power the system on off with VDC kept applied A power off controlled by the IGN signal has the same impact than removing VDC all PSUs are swit
11. Warning All operations on this device must be carried out by sufficiently skilled personnel only N Caution Electric Shock Before installing a not hot swappable Kontron product into a system always ensure that your mains power is switched off This applies also to the installation of piggybacks Serious electrical shock hazards can exist during all installation repair and maintenance operations with this product Therefore always unplug the power cable and any other cables which provide external voltages before performing work Earth ground connection to vehicle s chassis or a central grounding point shall remain connected The earth ground cable shall be the last disconnected or the first connected during operations of cabling Special Handling and Unpacking Instructions ESD Sensitive Device Electronic boards and their components are sensitive to static electricity Therefore care must taken during all handling operations and inspections of this product in order to ensure product integrity at all times Do not handle this product out of its protective enclosure while it is not used for operational purposes unless it is otherwise protected Whenever possible unpack or pack this product only at EOS ESD safe work stations Where a safe work station is not guaranteed it is important for the user to be electrically discharged before touching the product with his her hands or tools This is most easily done by touching a metal
12. Windows BSP for Windows 7 Windows 8 and Windows 7 Embedded in 32 or 64 bits are available through the customer section on Kontron COMe mBT10 webpage http www kontron com products computeronmodules com express com express mini come mbt10 emd 7 7 1 Feature supported by BSP The BSP delivers third party drivers like w Chipset Ethernet Graphic USB 3 0 Atom IO driver for GPIO I2C SPI HS UART SD2 SATA Audio Controller Intel amp High Definition Audio TPM TXE driver and some Kontron adapted drivers for w w 4 GPI and 4 GPO SM BUS Watchdog reset interrupt or timer mode NCT7802 HW Monitor for Voltage 3V3 VBAT 12V 5V EEPROM R W 2 BootCounter Boardlnformation SPI Temperatures CPU Temp and SYS Temp Many specific Kontron features accesses are implemented using the Kontron API KEAPI driver The driver access is specified in KEAPI Specification see documentation into BSP A demonstrative command tool is delivered ktool32 exe or ktool64 exe SD DT G45 0e Page 65 TRACe B304 TR User s Manual Reference Information The following display shows the ktool command syntax C Program Files Kontron Kontron EAPI gt ktoo132 exe Usage ktool lt API class lt API name gt lt command_type_args gt h Available API classes bat battery functions cpu cpu functions disk disk functions disp display functions eep eeprom functio
13. Figure 14 USB 3 0 Connector Pin Assignment SL 1 5V protected USB power 2 DATA Differential USB 3 DATA Differential USB 4 GND Ground 5 USBSS_RX Differential USB Receive 6 USBSS_RX Differential USB Receive 7 GND Ground 8 USBSS TX Differential USB Transmit 9 USBSS_TX Differential USB Transmit Table 9 USB 3 0 Connector Pin Assignment SD DT G45 0e Page 18 TRACe B304 TR User s Manual Getting Started with TRACe B304 TR 2 5 4 USB A USB 2 0 Connector The TRACe B304 TR have a USB 2 0 connector type A right angle Figure 15 USB 2 0 Connector Pin Assignment VCC 5V Protected 2 USB_D Differential USB 3 USB_D Differential USB 4 GND GND Table 10 USB 2 0 Connector Pin Assignment All the signal lines are EMI filtered SD DT G45 0e Page 19 B304 TR User s Manual Getting Started with TRACe B304 TR 2 5 5 SIM CARDS SIM Connectors The TRACe B304 TR have two SIM connectors SIM Card B SIM Card A SIM CARDS Figure 16 SIM Connector Pin Assignment NAME SIGNAL DESCRIPTION 1 VCC VCC 2 Reset RST 3 Clock CLK 4 SW1 SIM Detection 5 GND GND 6 VPP Not Connected 7 DATA DATA 8 SW2 GND Table 11 SIM Connector Pin Assignment SD DT G45 0e Page 20 B304 TR User s Manual Getting Started with TRACe B304 TR 2 5 6 DP DisplayPort Connector The TRACe B304 TR have a DisplayPort Interface Figure 17
14. https eshop phoenixcontact net phoenix treeViewClick do jsessionid TXZV8bq4RbGyRkRpdtxQJv1pnR ShypTWO07bpkvGXth1ZQQ6x61b2 1813238290 UID 852645997 amp parentUID amp reloadFrame true DP to VGA adapter Vendor RS Reference 790 3634 SD DT G45 0e Page 69 TRACe B304 TR User s Manual Appendix B List of Abbreviations AC DC COMe CPU DP ESD GND HMU LAN LED Os PCI S3 S4 S5 SATA SIM USB WEEE SD DT G45 0e Alternating Current Direct Current Computer On Module Express Central Processing Unit DisplayPort Electrostatic Sensitive Device Ground Health Management Unit Local Area Network Light Emitting Diode Operating System Peripheral Component Interconnect Suspend to RAM Suspend to Disk Soft Power Off Serial Advanced Technology Attachment Subscriber Identity Module Universal Serial Bus Waste Electrical and Electronics Equipment List of Abbreviations Page 70 G kontron MAILING ADDRESS TELEPHONE AND E MAIL Kontron Modular Computers S A S 33 0 4 98 16 34 00 150 rue Marcelin Berthelot BP 244 Sales Order ATD Toulon Kontron com Z TOULON EST Support GSS ATD Toulon Kontron com 83078 TOULON CEDEX France For further information about other Kontron products please visit our Internet web site www kontron com www kontron com
15. template optional script used by trace poweroffd to run some user tasks before final shutdown Tools trace config TRACe configuration tool gt trace cpld update to update the CPLD from file i2c transfer raw I2C tool to probe read write and debug gt port to do some read write accesses to I O ports gt i0 to do some read write accesses to the memory space services and tools listed above must run as root user N SD DT G45 0e Page 33 TRACe B304 TR User s Manual Getting Started with TRACe B304 TR 2 11 Windows n progress SD DT G45 0e Page 34 TRACe B304 TR User s Manual Deploying TRACe B304 TR Chapter3 Deploying TRACe B304 TR 3 1 Installing 3 1 1 Mounting Pre requisites Because the mounting position may impact thermal and mechanics properties the TRACe B304 TR system shall be integrated according to the following recommendations Physical Mounting Physical Orientation Thermal conditions gt Cabling Grounding Point Cabling 3 1 2 Physical Mounting In normal condition of use the EUT will be mounted on two horizontal mounting brackets one on each side The system shall be attached to the cabinet with four M5 screws of 12 mm length minimum assembled with adapted washers ISO 7093 series recommended The torque will depend on the thread material e CO O 0 SD DT G45 0e Figure 24 Physical Mounting Page 35 TRACe B304 TR
16. 001 In case of HMU alert SD DT G45 0e Page 58 TRACe B304 TR User s Manual Reference Information 7 6 Linux BSP 7 6 1 BSP Contents This distribution includes the standard Fedora 20 Linux release as well as the BSP packages related to the common platform COMe mBT10 and some additional specific drivers for TRACe system 7 6 1 1 OS Release gt Base Distribution Fedora 20 Package Management YUM RPM gt Distribution Website http www fedoraproject org gt Linux Kernel Linux 3 15 koX Semet 1 14 Default Graphical Environment LXDE 7 6 1 2 COMe BSP The COMe mBT 10 BSP is available through the customer section on the Kontron webpage http www kontron com products computeronmodules com express com express mini come mbt10 emd Full description of the following drivers and instructions for installation are provided in the corresponding README and INSTALL files Here the summary of the COMe mBT10 BSP features gt Kempld drivers Kontron PLD drivers to support following features PLD core needed by all other PLD drivers mfd kemp1d GPIO gpio kempld gt 12C i2c kempld Watchdog kempld wdt Kontron drivers gt Backlight kontron bl supports Backlight control using PWM and I2C depending on the BIOS backlight configuration This driver is also an alternative to 7 other PWM drivers p
17. 1 sim 1 mini socket 0 to 5 socket 1 to SIM B gpilwake off Wakeup from GPI1 NOT enabled gpiOwake off Wakeup from GPIO NOT enabled 1210 LAN C connector for Intel 1210 ethernet comb uart COM B connector for PCIe UART root trace board SD DT G45 0e Page 25 TRACe B304 TR User s Manual To display current settings Getting Started with TRACe B304 TR root trace board trace config c Current configuration serial 232 RS232 mode on COM B COM C serial lines serial full Full duplex on COM B COM C serial lines tpm on Second TPM chip ON start Start when ignition key is switched ON dport maint DisplayPort on maintenance plate connector sata minil SATA interface to mini socket 1 sim 0 1 mini socket 0 to SIM A socket 1 to SIM B gpilwake off Wakeup from GPI1 NOT enabled gpi0wake off Wakeup from GPIO NOT enabled lanc 1210 LAN C connector for Intel i210 ethernet comb uart COM B connector for PCIe UART offdelay 3 Power off delay in units of 1 4 seconds 0 to 255 0 absent Mini socket 0 PCIe device NOT present minil absent Mini socket 1 device NOT present mPCIe or mSATA minilsata absent Mini socket 1 SATA device NOT present 2 absent Mini socket 2 PCIe device NOT present mode normal System running in normal mode ledsysr off LED SYS red OFF ledalarmr off LED
18. 1D 0 Usb 0 0 Usb 2 0 Usb 3 0 HardDisk Alias 50 blko 0 Pc1 17 0 Ctr1 0 HD Part1 S1g3F46EF32 D69B 4A39 87AF hd39a0cOdOb Removable HardDisk Alias fs1 blki 0 1 1D 0 Usb 0 O Usb 2 0 Usb 3 0 HD Part1 S1 If BIOS image is named MVVRxxx bin then flash the BIOS entering command flash nsh fs1 gt flash nsh flash nsh fpt64 efi f MVVIR112 bin Intel R Flash Programming Tool Version 1 0 2 1062 Copyright 2007 2013 Intel Corporation All rights reserved Platform Bay Trail SpiLoadDevicesFile fparts txt Reading HSFSTS register Flash Descriptor Valid Flash Devices Found MX25L6405D 45E 36E 06E 73E ID 0xC22017 Size 8192KB 65536kb PDR Region does not exist Could not communicate with the HECI Reading Flash 0x800000 8192KB of 8192KB 100 complete Erasing Flash Block 0 71 000 100 complete Programming Flash 0 71 000 68KB of 68KB 100 complete Erasing Flash Block 0x724000 100 complete Programming Flash 0x724000 8KB of 8KB 100 complete Erasing Flash Block 0x73A000 100 complete Programming Flash 0x73A000 4KB of 4KB 100 complete Verifying Flash 0x800000 8192KB of 8192KB 100 complete Do not turn off nor reset the board until the end of the command This prevents the system to boot at next power on Wait about 1 minute and 3
19. 7 2 1 2 Unpacking 488 SRB 7 2 2 System Identification 8 23 AtaGlance SERA _ __ 9 2 4 Operational Side I O Connectors 11 241 DC IN External PSU M12 Connector Male 4 Pin A coded 11 2 4 2 LAN B LAN C Ethernet M12 Connectors Female 8 Pin X coded 12 243 COMB COM C Serial SUBD9 Connectors Male 9 Pin 13 244 GPIO SUBD25 Connector Female 25 Pin 14 2 4 5 Audio SUBD9 Connector Female 9 Pin 15 2 5 Maintenance Side I Os Connector 16 25 1 RJ 12 Connector 16 2 5 2 LAN A Gigabit Ethernet Port 17 2 5 3 USB B USB 3 0 Connector 18 2 5 4 USB A USB 2 0 Connector 19 2 5 5 SIM CARDS SIM Connectors 20 2 5 6 DP DisplayPort Connector 21 DIoME Dtional Cables Kits
20. DisplayPort Connector Pin Assignment SIGNAL FUNCTION 1 ML_Lane 0 p Lane 0 positive 2 GND Ground 3 ML_Lane 0 n Lane 0 negative 4 ML Lane 1 p Lane 1 positive 5 GND Ground 6 ML Lane 1 n Lane 1 negative 7 ML_Lane 2 p Lane 2 positive 8 GND Ground 9 ML Lane 2 n Lane 2 negative 10 ML Lane 3 p Lane 3 positive 11 GND Ground 12 ML Lane 3 n Lane 3 negative 13 GND Ground 14 GND Ground 15 AUX CH p Auxiliary Channel positive 16 GND Ground 17 AUX CH n Auxiliary Channel negative 18 Hot Plug Hot Plug Detect 19 Return Return for power 20 DP PWR Power for connector Table 12 DisplayPort Connector Pin Assignment SD DT G45 0e Page 21 TRACe B304 TR User s Manual Getting Started with TRACe B304 TR 2 6 Optional Cables Kits 2 6 1 TRACE KIT CAB EVAL y Ethernet Cable y M12 to RJ 45 1 brown T 2 whit Serial Cable 3 00 for COM A 4 black Power Cable 2 6 2 TRACE KITSATA 1 SD DT G45 0e Page 22 TRACe B304 TR User s Manual Getting Started with TRACe B304 TR 27 Plug and Play with TRACe B304 TR The following sections are only valid for Linux with TRACe BSP A live Fedora 20 demo image will be available on the Kontron Web Site under TRACe B304 TR download section 2 71 Plug Earth ground connection to vehicle s chassis or a central grounding point shall remain connected The earth ground cable shall be the last disconnected or the first connected during operat
21. SATA Power Connectors 1 5V vx GND 3 GND 4 12V Table 16 Onboard SATA Power Connectors Pinout SD DT G45 0e Page 53 TRACe B304 TR User s Manual Reference Information 7 3 BIOS BIOS Version The BIOS version is accessible in DMI table under OS dmidecode for Linux It is also available in BIOS SETUP in system information in Main menu BIOS on Serial Line By default the BIOS console does not show up on COM A or To have the BIOS accessible on serial line the SETUP option Console redirection in MAIN menu must be enabled on COM A or COM B However enabling this option will strongly slow down the Graphical BIOS access This is a BIOS limitation on TRACe So this option must be set only if graphical BIOS access is not used Also the serial line speed must be set to 115200 it is 9600 by default to access the BIOS SETUP by serial line and to avoid to considerably slow down a verbose Linux boot SD DT G45 0e Page 54 TRACe B304 TR User s Manual Reference Information 7 4 CPLD The cPLD implemented on the carrier board implements some registers mapped to the LPC bus These registers can be accessed at I O base address 0x800 register offset 0x00 to 0x3F 0x00 0x0F MISC REGISTERS managed by the trace_config tool 0x10 0x15 12 REGISTERS managed by the trace cpld i2c driver 0x20 0x29 SPI REGISTERS managed by the trace cpld micro driver 0x30 0x35 cPLD FLASH REGISTERS managed by the tra
22. User s Manual Deploying TRACe B304 TR 3 1 3 Physical Orientation The equipment is in its normal position of use when axis Z is vertical and upwards oriented as described below 3 1 4 Horizontal Mount e Figure 25 Horizontal Mount 3 1 5 Vertical Mount Figure 26 Vertical Mount SD DT G45 0e Page 36 TRACe B304 TR User s Manual Deploying TRACe B304 TR 3 1 6 Thermal Conditions To place the Box unit in well conditions free minimal volume shall be respected around the system h is the height of the Box unit h 77 5mm Free volume is defined by the free minimal distances as follows In X direction 2 h gt In X direction 2 h gt In Y direction 2 h gt In Y direction 2 h gt In Z direction 3 h gt In Z direction 0 Nw air surrounding into the free volume shall not exceed 70 in continuous and 85 C during 10 min SD DT G45 0e Page 37 TRACe B304 TR User s Manual Deploying TRACe B304 TR 3 1 7 Cabling The Box unit environment shall allow the access to all connectors with consideration of the cables minimum radius The cables must be of sufficient length as to guarantee that the Box unit can be safely installed or removed from its mounting position and have the cables be installed or removed without the possibility of the Box unit falling or otherwise being damaged 3 1 8 Grounding Point Cabling As the operational grounding concept of the TRACe B304 TR
23. calls for a ground point connection of the chassis to external ground there must always be a ground connection to the chassis This is accomplished via an M4 stud with an external ground wire attached installed on the operational plate Refer to the figure below for an example of assembly details M4 stud Flat washers Serrated washer External ground TRACe operational plate cable Figure 27 Assembly of the Grounding Point Connection Grounding Concept Externally the TRACe B304 TR is grounded via an M4 screw terminal point From this terminal point a grounding wire must be connected to the vehicle s chassis or a central grounding point The following table and figure provide further information concerning TRACe B304 TR grounding Operational DIO GPIO SUBD25 Yes Ethernet LAN B M12 Yes Ethernet LAN C M12 Yes Audio Audio SUBD9 No Serial COM B SUBD9 Yes Serial COM C SUBD9 Yes External Ground Shield Ground M4 Yes SD DT G45 0e Page 38 TRACe B304 TR User s Manual Deploying TRACe B304 TR Maintenance Ethernet LAN A RJ45 No USB 2 0 USB USB 2 0 No USB 2 0 amp 3 0 USB B USB 3 0 DP DP DP SIM SIM CARD SIM CARD Serial A RJ 12 Sockets PCIe Mini or mSATA Cards Depends on mXCards lt No Table 14 TRACe B304 TR Grounding TRACE B304 TR housing CON connector shell PCB Ae PAn electrical ground to housing shield ground i non isolated 1 05 audio isolated I Os serial Eth SIM DP
24. d debug Also print debug settings including for this help r reset Reset saved and or current settings to defaults including debug settings if debug also specified Current settings are loaded from saved settings at power on Some settings do not support modification of their current runtime value only modification of their saved value is allowed The list below shows all valid options arguments pairs that can be used on command line after the ones listed above If none is provided this program displays all settings saved and or current If only options are supplied without argument only the related settings are displayed If both options arguments are supplied the related settings are updated Several options arguments can be supplied in the same command line 5 1 232 RS232 mode COM B COM C serial lines serial 485 RS422 485 mode on COM B COM C serial lines serial full Full duplex on COM B COM C serial lines serial half Half duplex on COM B COM C serial lines tpm on Second TPM chip ON tpm off Second TPM chip OFF start Start when ignition key is switched ON wait Wait GPI uC event when ignition key is switched ON dport maint DisplayPort on maintenance plate connector dport j2602 DisplayPort on J2602 sata minil SATA interface to mini socket 1 sata j2201 SATA interface to J2201 connector sim Oalb mini socket 0 to SI
25. part of your system housing It is particularly important to observe standard anti static precautions when changing piggybacks ROM devices jumper settings etc If the product contains batteries for RTC or memory backup ensure that the board is not placed on conductive surfaces including anti static plastics or sponges They can cause short circuits and damage the batteries or conductive circuits on the board SD DT G45 0e Page iv Preface TRACe B304 TR User s Manual General Instructions on Usage In order to maintain Kontron s product warranty this product must not be altered or modified in any way Changes or modifications to the device which are not explicitly approved by Kontron and described in this manual or received from Kontron s Technical Support as a special handling instruction will void your warranty This device should only be installed in or connected to systems that fulfill all necessary technical and specific environmental requirements This applies also to the operational temperature range of the specific system version which must not be exceeded In performing all necessary installation and application operations please follow only the instructions supplied by the present manual Keep all the original packaging material for future storage or warranty shipments If it is necessary to store or ship the product please re pack it as nearly as possible in the manner in which it was delivered Special care is necessar
26. processed by the command TRACe SysMngr gt set SD DT G45 0e Page 56 TRACe B304 TR User s Manual Reference Information List and syntax of subcommands are provided by TRACe SysMngr gt set vpd help Usage set parameter lt parameters gt with parameter system TRACe system VPD with parameters carrier Carrier VPD come COMexpress VPD IOB 10 Board VPD init initialize VPD areas in eeprom 7 5 2 2 Supervision TRACe SysMngr show temp Temperatures HHHHRHHEHHE Carrier Therm Sensor 43 degC COMe Therm Sensor 39 degC PSU Therm Sensor 40 degC Displays the temperature inside the TRACe system TRACe SysMngr show volt THRSHHHHHE Voltages FHHSHHHRHHE 5V_STDBY 5000 mV 12V 11362 mV ALARM below voltage limit 3V3 3352 mV 3V3_STDBY 3502 mV ALARM above voltage limit 5V 5039 mV HHHHHHHHE Current 12V_CURRENT SENSE 970 mA Displays the voltage and current level the ALARM messages are examples TRACe SysMngr gt show cbit THHRHHRHHHE STATUS 12C Carrier Errors 0 12C I0B Errors 0 Thermal sensor Carrier Therm Sensor status OK Thermal sensor COMe Therm Sensor status OK Thermal sensor PSU Therm Sensor status OK 12C Carrier alive 2 issue on IO Board COMe Port80 status 0 0 Displays the status of miscellaneous health parameters of the systems SD DT G45 0e Page 57 TRACe B304 TR User s Manual Referen
27. report log and transmit any out of specs parameters and or any failures at power on and during operations of TRACe B304 TR 1 2 2 Ordering Information Available Order Codes TRACe B304 TR EN50155 certified fanless Operational Computer Intel Atom E3845 Bay Trail quad core 1 91 GHz COMe CPU 2 GB DDR3 with ECC 8 GB SLC Flash mPCle slots Wide range Railway certified PSU 24 VDC 110 VDC EN50155 Class TX 40 to 70 C 10 min 85 C IP50 TRACE KIT CAB EVAL Set of Cables for TRACe B304 TR evaluation consisting of 1x CABLE ASSY Power M12 A coded to free end 1x ETHERNET M12 X coded to RJ45 1x Serial RJ 12 to dual DB9 TRACE KITSATA 1 Set of SATA cables to install one 2 5 SSD on TRACe B304 TR consisting of 1xSATA Power cable 1x SATA Data cable 4x screws and spacers TRACE STARTER KIT TRACE COVMNT V01 Cover Plate for Maintenance Side Dust Protection Table 1 TRACe Order Codes SD DT G45 0e Page 3 TRACe B304 TR User s Manual 1 2 3 Operational Side View Front View TRAC Optional Plate for additional gt ND e Introduction Introducing Operational and Maintenance Side Views F a oO AUDIO OMB GPIO COMC E 3 S3 5 6 7 Figure 2 TRACe B304 TR Front View custom I O 4 1 Wide Range 24V 110V DC Power Supply input 2 Serial lines RS232 RS422 RS485 3 Audio Stereo Line In Stereo Line Out 4 Gigabit Ethernet ports
28. system complies with the following standards 50121 3 2 50127 50128 50155 2007 EN 50155 2007 EN 55011 8 12 2 8 2 NF EN 60068 2 1 2007 NF EN 60068 2 2 2007 NF EN 60068 2 11 1999 NF EN 60068 2 27 2009 NF EN 60068 2 30 2006 NF EN 60068 2 64 2008 NF EN 60529 2000 EN 60950 1 2006 1 2010 A2 2013 A11 2009 A12 2011 EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 NF EN 61373 2011 04 SD DT G45 0e Reference Information Page 68 TRACe B304 TR User s Manual References Appendix A References A 1 Associated Documentation The following documentation is available on the Kontron web site gt Datasheet TRACe B304 TR 06092014MB gt TRACe B304 TR Quick Start 22 2 SD DT G39 A 2 Accessories References Examples M12 Connector for Power Cable Vendor Phoenix contact Reference 1521601 http fr rs online com web p connecteurs et cables pour interrupteurs et capteurs 6528201 Vendor Weidmuller Reference 9457240000 http catalog weidmueller com procat Product jsp jsessionid 408DEB4DCB7EDC2E0F7B518824DAE36 B productld 5b9457240000 5d amp page Product Ethernet M12 to RJ45 Cable gt Vendor Phoenix Contact Reference 1407471
29. 0 seconds and check if message RESULT The data is identical is displayed If not do not reset and do again the flash update When upgrade is finished without any errors then turn off the system and do a fresh cold start in order to boot with the new BIOS SD DT G45 0e Page 42 TRACe B304 TR User s Manual Updating TRACe 4 1 2 Record BIOS image ROM and setting from UEFI Shell using USB device This section details the record of the TRACe BIOS Firmware and its SETUP configuration A USB key will be used to store the BIOS image Before starting install the Firmware Update Utility on a USB key see previous section to locate them The USB key must be formatted in FAT32 ou NTFS and shall contents gt fparts txt gt fpt64 efi Operating Mode Boot TRACe on UEFI shell If necessary enter the BIOS Boot Menu pressing lt F5 gt during the boot sequence Then navigate and select UEFI shell in Boot override menu and boot under UEFI shell Boot Menu App Menu eMMC Card0 DISK Internal Shell USB HDD Kingston DataTraveler 3 0 i v y Move Colla Tab Switch Menu Select ESC Exit Plug the USB device on the concerned USB interface Enter command map r Then input the fs1 command to switch to the root of the USB flash drive fs1 file system must become visible 51 Eventually use fs2 fs3 case of other File syst
30. 0e Page 6 B304 TR User s Manual Getting Started with TRACe B304 TR Chapter 2 Getting Started with TRACe B304 TR 2 1 Receipt of the Equipment 2 1 1 Checking the Packages Inspecting the packing cartons and verifying their condition is the responsability of the customer and should be carried out upon delivery gt Inspect the packing and check its condition no broken corners gt general state of the case no rips or holes gt condition of the bands and the clips If you wish to report any damage in transit you should make out a full report and also note the damage on the packing list that accompanies the equipment Ensure that the report and the packing list are signed by yourself and also by the transport agent and send a copy of these documents to the transport company Kontron 2 1 22 Unpacking Unpacking the equipment must be carried out under the supervision of an authorized technician gt Open the package and take out the items one by one Inspect each item and make a note of any possible defects scratches marks or blemishes damaged cables etc If necessary make a report of any damage or defects Checkthe equipment against the packing list and report any missing items gt It is recommended that you keep the package and the anti shock protection This will be required if val you decide to move your system to a different site SD DT G45 0e Page 7 TRACe B304 TR User s Manua
31. 4 kontron SD DT G45 0e February 2015 Preface TRACe B304 TR User s Manual Revision History Publication Title TRACe B304 TR User s Manual Doc ID SD DT G45 0e Re Brief Description of Changes Date of Issue Oe Initial Issue 202 2015 7 4 lt a Ww Copyright 2015 Kontron AG All rights reserved All data is for information purposes only and not guaranteed for legal purposes Information has been carefully checked and is believed to be accurate however no responsibility is assumed for inaccuracies Kontron and the Kontron logo and all other trademarks or registered trademarks are the property of their respective owners and are recognized Specifications are subject to change without notice Page i SD DT G45 0e TRACe B304 TR User s Manual Preface Proprietary Note This document contains information proprietary to Kontron It may not be copied or transmitted by any means disclosed to others or stored in any retrieval system or media without the prior written consent of Kontron or one of its authorized agents The information contained in this document is to the best of our knowledge entirely correct However Kontron cannot accept liability for any inaccuracies or the consequences thereof or for any liability arising from the use or application of any circuit product or example shown in this document Kontron reserves the right to change modify or imp
32. 485 mode Full duplex on serial on COM B COM C serial lines COM B COM C serial lines on COM B COM C serial lines COM B COM C serial lines Page 27 TRACe B304 TR User s Manual 2 8 Device Management 2 8 1 Power status LED Getting Started with TRACe B304 TR amp a8 Figure 19 Power On LED OFF GREEN GREEN PULSE ONCE every 2 seconds GREEN PULSE TWICE every 2 seconds SLOW BLINKING GREEN with period 1 second FAST BLINKING GREEN with period 0 5 second ORANGE red green POWER RED 2 8 2 Status and User LEDs System power off Ignition key OFF or forced to OFF by REG_POWER System running System in standby mode S3 S4 or S5 state System waiting for power on event GPI uC command System about to power off power off delay In debug mode System reset from COME CB_RESET asserted Power error Power supplies are switched off and an error code is reported on USERO 1 LEDs L1 L2 L3 L4 15 MAINTENANCE L1 L2 L3 L4 L5 re RST m d COMA SIM CARDS USBB LANA Ethernet LEDs Figure 20 Status LEDs gt Five Status User LEDs L1 User1 L2 User0 L3 Alarm HMU L4 Sys SATA L5 Power SD DT G45 0e Page 28 TRACe B304 TR User s Manual Getting Started with TRACe B304 TR These LEDs are bicolor red and green giving 4 possible states off red green orange gt L1 and L2 are controlled by the cPLD L3 and 14 are controll
33. 5 RS 422 RS 485 Full Duplex Half Duplex RX A N C TX 2 TX RX Z B N C N C N C N C N C N C TX Y TX RX Y A RX B N C N C N C Table 4 COM B COM C Connectors Pin Configuration N Two naming conventions are used for RS 422 RS 485 differential signals they match each other voli as follows TX Y TX Z RX RX B The serial mode and duplex can be set using the trace config tool When in 485 mode the RTS signal from the UART is no more available on the connectors but is used as a TX enable transmit enable when RTS is high logic 1 driven by UART TX is enabled TX is disabled by switching RTS low under Linux OS RTS can be managed by the TIOCMGET TIOCMSET IOCTL using the TIOCM RTS flag COM B is muxed between UART default and HMU can be selected by the trace config tool When in HMU mode transmit is always enabled RTS always at 1 so only RS 232 and RS 422 are supported See COM A for HMU serial line routing to COM A or COM B SD DT G45 0e Page 13 B304 TR User s Manual Getting Started with TRACe B304 TR 2 4 4 GPIO SUBD25 Connector Female 25 Pin 13 1 25 14 Figure 10 GPIO Connector Pin Configuration 1 GND GPIO ISO 14 GPIO IN 0 2 GND GPIO ISO 15 GPIO IN 1 3 GND GPIO ISO 16 GPIO IN 2 4 GND GPIO ISO 17 GPIO IN 3 5 N C 18 N C 6 N C 19 N C 7 20 8 21 24 VISO external 9 GND_GPIO_ISO 22 GPIO_OUT 0 10 GND_GPIO_ISO 23 GP
34. 51 gt sys class gpio export root trace board echo 252 gt sys class gpio export root trace board echo 253 gt sys class gpio export root trace board echo 254 gt sys class gpio export root trace board echo 255 gt sys class gpio export root trace board echo out gt sys class gpio gpio252 direction GPIO OUT O0 root trace board echo out gt sys class gpio gpio253 direction GPIO OUT 1 root trace board echo out gt sys class gpio gpio254 direction GPIO OUT 2 root trace board echo out gt sys class gpio gpio255 direction GPIO OUT 3 SD DT G45 0e Page 63 TRACe B304 TR User s Manual root trace board echo root trace board echo root trace board echo root trace board echo in gt sys class gpio gpio248 direction in gt sys class gpio gpi0249 direction in gt sys class gpio gpio250 direction in gt sys class gpio gpio251 direction Reference Information GPIO IN 0 GPIO IN 1 GPIO IN 2 GPIO IN 3 Then the value of each GPIO can be set or read using a sys class gpio gpio lt number gt value device Examples gt Set GPIO OUTT 0 active drives open collector output to 0 root trace board echo 1 gt sys class gpio gpio252 value gt Read level on GPIO_IN 0 root trace board cat sys class gpio gpio248 value 0 SD DT G45 0e Page 64 TRACe B304 TR User s Manual 7 7 Windows BSP Reference Information
35. 9 12 2014 10 36 Fichier HEX Emplacements r cents Biblioth ques A SN Ordinateur b n 6 Nom du fichier R seau Types de fichiers Hex File hex Y Annuler Ouvrir en lecture seule Navigate to the repository where the file has been uploaded and select it Hex file loaded successfully Press the Button Erase Program Veri fy Flash Erased Programming completed Verification successful In the TRACe machine terminal type the commands root trace board trace config c lanc i210 root trace board trace config c ucctl reset root trace board trace config c ucct normal The first command re allocates LANC interface to Gigabit Ethernet interface ethO The second command resets the microcontroller The third command starts the microcontroller in operational mode On the microcontroller serial interface the new firmware version can be checked with the following command TRACe SysMngr show version TRACe SystMngr version 0 15 Dec 19 2014 10 22 30 SD DT G45 0e Page 46 TRACe B304 TR User s Manual Updating TRACe 44 OSSW TRACe Fedora 20 live image is available on Kontron Website TRACe B304 Download section By design TRACe BSP updates come with the COM Express board BSP updates Please refer to chapter 7 6 Linux BSP page 59 and 7 7 Windows BSP page 65 SD DT G45 0e Page 47 TRACe B304 TR User s Manual Getting Help Chapter5 Getting Help H
36. ALARM red OFF ledusrl off LED USER1 is OFF ledusr0 off LED USERO is OFF sysstate 0 Current system state code 0 to 15 updated by soft cpldrev 0x04 CPLD revision version on carrier board root trace board The help gives the list of all possibles settings and their supported values root trace board trace config h To also see debug settings root trace board trace config d h Some of them are read only or and only apply to the current or saved settings A See chapter 7 Reference Information page 50 for full command output gt EXAMPLES gt Switch LED L2 User0 to red right now root trace board trace config c ledusr0 red gt Get current LED L2 UserO state root trace board trace config c ledusr0 Current ledusr0 red LED USERO is RED root trace board SD DT G45 0e Page 26 TRACe B304 TR User s Manual Getting Started with TRACe B304 TR Set serial lines to 422 485 at next power on saved setting root trace board trace config serial 485 Set serial lines to 422 485 right now current setting root trace board trace config c serial 485 Get serial lines configuration for both saved and current settings root trace board trace config c s Saved serial 485 serial full Current serial 485 serial full root trace board SD DT G45 0e RS422 485 mode Full duplex on RS422
37. CI Express Card It can also be filled with any Mini PCI Express Card Full size only F1 or F2 types 7 1 3 Assembly and Dismantling Instructions In progress SD DT G45 0e Page 51 TRACe B304 TR User s Manual Reference Information 7 2 Onboard Connectors MiniPCIE 0 MiniPCIE 1 MiniPCIE 2 SATA Power Connectors Figure 29 Onboard Connectors 7 21 M MiniPCle Connectors These connectors are compliant with the PCI Express Mini Card Electromechanical Specification Revision 1 2 Revision 1 2 October 26 2007 gt MiniPCIE 0 connector Accept full or half size of MiniPCIExpress cards and mUSB devices gt MiniPCIE 1 connector Accept only full size of MiniPCIExpress cards mUSB devices and mSATA modules gt MiniPCIE 2 connector Accept only full size of MiniPCIExpress cards SD DT G45 0e Page 52 TRACe B304 TR User s Manual Reference Information 7 2 22 SATA DATA Connectors The following figure and table provide pinout information for the SATA connectors 7 1 Figure 30 Onboard SATA DATA Connectors 1 Ground signal 2 SAG Differential Transmit D xe 3 SATA_TX Differential Transmit 4 GND Ground signal im 5 SATA_RX DifferentialReceive 6 SATA_RX Differential Receive a 7 GND Groudn Signal N WV Table 15 Onboard SATA DATA Connectors Pinout 7 2 3 SATA Power Connectors The following figure and table provide pinout information for the SATA power connectors Figure 31 Onboard
38. IO_OUT 1 11 GND_GPIO_ISO 24 GPIO_OUT 2 12 GND_GPIO_ISO 25 GPIO_OUT 3 13 GND_GPIO_ISO 26 27 Shield Table 5 GPIO Connector Pin Configuration 24 VISO DC voltage 8 VDC min 29 VDC max must be applied to pin 21 to power the isolated GPIO logic GPIO_OUT n are open collector outputs enabled driven low to GPIO ISO when a logic 1 is written from software Each output can sink up to 20 mA Maximum voltage on GPIO OUT n to GND GPIO ISO is 29 VDC GPIO IN n are inputs that are read at 1 from software when at logic level high 24V logic Maximum voltage on GPIO IN n to GPIO ISO is 29 VDC These inputs have an hysteresis around 1V level high is above 17V level 0 under 16V GPIO OUT n and GPIO IN n can have a voltage greater than 24 VISO provided than this voltage does not exceed 29 VDC SD DT G45 0e Page 14 TRACe B304 TR User s Manual Getting Started with TRACe B304 TR 2 4 5 Audio SUBD9 Connector Female 9 Pin Figure 11 Audio Connector Pin Configuration x SD DT G45 0e Signal Name LINE OUT L Headphone GND AUDIO LINE OUT R Headphone GND AUDIO AUDIO LINE MICBIAS 5V internal LINE IN L Microphone GND AUDIO LINE R Microphone Table 6 Audio Connector Pin Configuration Page 15 TRACe B304 TR User s Manual Getting Started with TRACe B304 TR 2 5 Maintenance Side I Os Connector Pinout 2 5 1 RJ 12 Connector Figure 12 COM A Connector Pin Con
39. M A socket 1 to SIM B sim 1b mini socket 1 to SIM B sim 0a mini socket 0 to SIM A sim 05 mini socket 0 to SIM B gpilwake off Wakeup from GPI1 NOT enabled gpilwake Wakeup from GPI1 enabled gpiOwake off Wakeup from GPIO NOT enabled gpiOwake Wakeup from GPIO enabled 1210 LAN C connector for Intel 1210 ethernet LAN C connector for microcontroller ethernet comb uart COM B connector for PCIe UART SD DT G45 0e Page 61 TRACe B304 TR User s Manual comb offdelay 0 miniO 1 1 minilsata minilsata 2 2 mode mode ledsysr ledsysr ledalarmr ledalarmr ledusrl ledusr0 ledusr0 ledusr0 ledusr0 sysstate cpldrev uc lt value gt present absent present absent present absent present absent normal debug off on off on off red green amber off red green amber lt value gt lt hexvalue gt root trace board COM Power off delay in units of 1 4 seconds 0 to 255 Mini Mini Mini Mini Mini Mini Mini Mini System running in normal mode System running in debug mode LED LED LED LED LED LED LED LED LED LED LED LED Current system state code 0 to 15 updated by soft cPLD revision version on carrier board Reference Inf
40. MC Card0 DISK Internal Shell USB HDD Kingston DataTraveler 3 0 v y Move lt gt Colla Tab Switch Menu Select ESC Exit Plug the USB device on the concerned USB interface Enter command map r Then input the 51 command to switch to the root of the USB flash drive fs1 file system must become visible 51 SD DT G45 0e Page 41 TRACe B304 TR User s Manual Updating TRACe Eventually use fs2 fs3 in case of other File system devices presence Use cd command to reach a directory where the Bios image is stored Use 1s to display files list HardDisk Alias hd23b bLko PNPOAOS 0 1 17 0 Ctr1 0 HD Part1 Sig3F46EF32 D69B 4A39 87AF Removable HardDisk Alias hd39a0cOd0b blki Acpi 0 Pci 1D 0 Usb 0 0 Usb 2 0 Usb 3 0 HD Part1 S19g00000 HardDisk Alias hd23b fso Acpi Pci 17 0 Ctrl 0 HD Part1 Sig3F46EF32 D69B 4A39 87AF Removable HardDisk Alias hd39a0codob 51 0 Pci 1D 0 Usb 0 0 Usb 2 0 Usb 3 0 HD Part1 51900000 HardDisk Alias null 0 1 17 0 Ctrl 0 HD Part2 S196020B71A 412E 44B7 B74B BlockDevice Alias null Pci 17 0 1 0 Removable BlockDevice Alias null 1 PNPOAOS3 0 Pc1i
41. anings of 103 106 and 109 respectively The only exception to this is in the description of the size of memory areas when K M and mean 210 220 and 230 respectively When describing transfer rates k M and G mean 103 106 and 109 not 270 220 and 230 N In PowerPC terminology multiple bit fields are numbered from 0 to n where 0 is the MSB and n is the LSB PCI and CompactPCI terminology follows the more familiar convention that bit 0 is the LSB and n is the MSB Signal names ending with an asterisk or a hash denote active low signals all other signals are active high Signal names follow the PICMG 2 0 R3 0 CompactPCI Specification and the PCI Local Bus 2 3 Specification Page iii SD DT G45 0e TRACe B304 TR User s Manual Preface For Your Safety Your new Kontron product was developed and tested carefully to provide all features necessary to ensure its compliance with electrical safety requirements It was also designed for a long fault free life However the life expectancy of your product can be drastically reduced by improper treatment during unpacking and installation Therefore in the interest of your own safety and of the correct operation of your new Kontron product you are requested to conform with the following guidelines High Voltage Safety Instructions As a precaution in case of danger the power connector is the product s main disconnect device and must be easily accessible
42. are PIC32UBL PC must be configured as a server on a subnet 192 168 1 in order to download firmware on the TRACe machine configured by default at the IP Address 192 168 1 11 Launch the PIC32UBL program on PC The following interface is displayed Enable Ethernet Communication setting 5 PIC32 Bootloader Application V1 2 Ves Communication Settings Serial Port Com Port Baud Rate COMI 115200 USB VID PID 0 03 Enable Ethernet IP Address 192 168 UDP Port 6234 On the TRACe machine log in and type commands root trace board trace config c ucctl reset root trace board trace config c ucctl boot root trace board trace config c lanc uc The first command puts the HMU in reset The second command sets the HMU in firmware updating mode The last command configures the TRACe machine to accept Ethernet traffic towards microcontroller on LANC interface Then in the PIC32UBL interface press the Connect button The following message is displayed Device connected Bootload firmware Version 1 4 When in bootloading mode the Maintenance Panel L3 Green LED blinks quickly press the Load Hex File but ton SD DT G45 0e Page 45 TRACe B304 TR User s Manual Updating TRACe A Popup Browser opens to select the firmware hex file provided by Kontron Ouvir Regarder dans F trunk ect E3 a Nom Modifi le Type n ww TRACe SysMngr X production hex 1
43. ce Information TRACe SysMngr gt show logs 11 03 15 14 32 39 WARNING 3V3_STDBY limit reached 3486 mV 11 03 15 14 32 38 WARNING 12V limit reached 11362 mV 11 03 15 14 32 33 Startup 11 03 15 14 32 26 Startup 11 03 15 14 32 17 Startup Displays the recorded warnings or alarm events of the system ALARM events are examples TRACe SysMngr gt set date 00 48 14 3 11 03 15 TRACe SysMngr gt show date 11 03 15 14 48 04 Sets and shows date for events recording 7 5 2 3 Control Management Power Management Reset Management to be defined later according to a predefined policy 7 5 2 4 Alarm Management When a monitored event thermal voltage current interface health is out of its limits or in default an interrupt IRQ10 is generated towards the COMe board via the CPLD This interrupt must be handled on COMe board For example under Linux gt Wait on event blocking command is performed by root trace board cat lt sys class trace cpld event event wait2 Device wait is reserved for the trace poweroffd daemon so use wait2 or wait3 here iN Read the status of the event non blocking command is done by root trace board cat lt sys class trace cpld event event get The data returned is based on the information in CPLD register POWER 0 0 ign key switched off power forced off by FORCE OFF bit event from IRQIO SET bit gt For example it can be
44. ce cpld update tool for cPLD update Please concact Kontron for a detailed description of these registers SD DT G45 0e Page 55 TRACe B304 TR User s Manual Reference Information 7 5 Healh Management Unit 7 5 1 Overview The Health management unit implemented in a Microchip PIC32 microcontroller provides the following management facilities gt Inventory Vital Product Data of the TRACe machine gt Supervision monitoring of thermal sensors voltage sensors health status of internal interfaces I2C bus devices log events Control Management This feature will be implemented later All alarm alert events are backuped in EEPROM area The log area is a cyclic pool of 256 events Each event has a 64 byte length including date stamp Currently the HMU interface is provided on Serial port RJ 12 on the Maintenance side Parameters for this serial line interface are 9600 bauds 8 bit No Parity No flow Control 7 5 2 Basic Commands Globally commands are listed by TRACe SysMngr help TRACe show Show TRACe information set Set TRACe information debug Debug TRACe functionalities RESERVED USE 7 5 2 1 Inventory TRACe SysMngr show vpd And its subcommands TRACe SysMngr show vpd system TRACe SysMngr show vpd carrier TRACe SysMngr show vpd IOB TRACe SysMngr show vpd come List and syntax of subcommands are provided by TRACe SysMngr show vpd help VPD can be
45. ched off including standby power supplies However using IGN to power on off is recommended because this enables some extra features such as an automatic system shutdown with a delayed power off when the IGN signal is disabled or a system wakeup from sleep by toggling the IGN signal N Even if IGN is expected to be connected to VDC it can be alternatively connected to another voltage Me source with same GND POWER IN and a voltage in the same range than the one required for VDC VDC and IGN voltage range to GND 24 VDC 110 VDC nominal 17 VDC min 138 VDC max Current on VDC for VDC 24 VDC when idle under BIOS or Linux OS around 800 mA Current on IGN for all IGN voltage range around 4 mA SD DT G45 0e Page 11 TRACe B304 TR User s Manual Getting Started with TRACe B304 TR 2 4 2 LAN B LAN C Ethernet M12 Connectors Female 8 Pin X coded View from Receptacle Side Figure 8 LAN B LAN C Connectors HMU 10 100 Ethernet interface can be routed to LAN C can be selected by the trace_config tool Pin Configuration DA DA DB DB DD DD DC DC ON Oak Table 3 LAN B LAN C Connectors Pin Configuration SD DT G45 0e Page 12 TRACe B304 TR User s Manual Getting Started with TRACe B304 TR 2 4 5 COMB COM C Serial SUBD9 Connectors Male 9 Pin Figure 9 COM B COM C Connectors Pin Configuration N C RX TX N C GND N C RTS CTS N C OMAN DOA FP ON RS 422 RS 48
46. cting TRACe 04 23 Figure 19 Power On LED T 28 Figure 20 Status LEDs uoo aAA oo oe o oo o o e Rm RR 28 Figure 21 Computer Reset 9 30 Figure 22 TRACe as a BOXOPC WEBB ES 31 Figure 23 TRACe as a monitored Operational Computer 32 Figure 24 Physical 35 Figure 25 Horizontal 36 Figure 26 4f amp gpticalliffount 36 Figure 27 Assembly of the Grounding Point Connection 38 Figure 28 TRACe B304 TR 39 Figure 29 Onboard Connectors 52 Figure 30 Onboard SATA DATA Connectors 53 Figure 31 Onboard SATA Power Connectors 53 Figure 32 Ignition Implementation 7 67 Page ix SD DT G45 0e TRACe B304 TR User s Manual Table Of Contents List Of Tables Table 1 TRACe Order Cod
47. d as a daemon started automatically at system boot The trace shutdown script script can be modified to add some user specific tasks to do before the final shutdown occurs 7 6 4 I Os 7 6 4 1 COM devices routing sde dmesg lspci connector ttySO 00 04 COMe UART port 0 COM A connector 0 0 3 8 IRQ 4 ttyS1 00 05 COMe UART port 1 NC 0 0 218 ORQ 3 0 carrier UART port 2 NC 0 carrier UART port 3 NC 0 carrier UART port 0 COM C connector 0 carrier UART port 1 COM B connector MIO 0x90500c00 IRQ 17 MIO 0x90500000 IRQ 17 8 0 0x90500400 IRQ 17 muxed with HMU console eI eI MMIO 0x90500800 IRQ 17 M e M SH SHR He CH 7 6 4 2 LAN devices routing zdey dmesg 1spci chip 2 ethO 0000 05 00 0 carrier 1210 LAN C connector muxed with HMU ethernet ethl 0000 06 00 0 carrier i210 A LAN B connector eth2 0000 0 00 0 COMe 1210 LAN A connector 7 6 4 3 GPIOs The gpio kempld driver manages 8 COMe GPIOs that are available on the SUBD25 connector on the operational side Before beeing used these GPIOs must be configured as follows 4 as outputs 4 as inputs root trace board echo 248 gt sys class gpio export root trace board echo 249 gt sys class gpio export root trace board echo 250 gt sys class gpio export root trace board echo 2
48. ed by the cPLD for red color Alarm Sys but not for green color HMU SATA L5 Power has the same state than the Power status LED on operational side To control the LEDs through the cPLD the trace config tool can be used trace config c ledXXXX YYYY When L5 Power is red power error an error code is reported on L1 User1 and L2 User0 as follows EICLLIMNEMNEN IL NENNEN NEST CNN UN 75 ERR NO ERROR 1 ERR STDBY 5V 3V3 OFF GREEN 2 ERR SUS S3 OFF RED 3 ERR 3V3 5V OFF ORANGE 4 ERR 12V GREEN OFF 5 ERR 2V5 GREEN GREEN 6 ERR 1VO GREEN RED 7 ERR 1V5 GREEN ORANGE 8 ERR UART RED OFF 9 ERR PCIESW LOCK RED GREEN 10 ERR SUS STAT RED RED 11 ERR EMERGENCY OFF RED ORANGE Ethernet status LEDs LEDs STATUS SPEED LED ACT LED Ethernet link is not established OFF OFF Ethernet link establisehd OFF ON 10 100 Mbps Ethernet Link Activity OFF BLINK Ethernet link establisehd ON ON 1000 Mbps Ethernet Link Activity ON BLINK Table 13 Ethernet LEDs Status Definition SD DT G45 0e Page 29 TRACe B304 TR User s Manual Getting Started with TRACe B304 TR 2 8 3 Computer Reset MAINTENANCE L1 L2 L3 L4 L5 re RST SIM CARDS USBA COMA USBB mm RST button on Maintenance rear side Figure 21 Computer Reset SD DT G45 0e Page 30 TRACe B304 TR User s Manual Getting Started with TRACe B304 TR 2 9 Health Management Unit Use Cases 2 9 1 TRACe as a Box PC PSU EN50155 mCOMe Processor Intel Ato
49. elp is provided by documentation and Kontron Support support kontron com Before contacting Kontron support please collect information on TRACe Machine This information can be displayed on HMU serial line by typing the command TRACe SysMngr gt show vpd SD DT G45 0e Page 48 B304 TR User s Manual Customizing TRACe B304 TR Chapter6 Customizing TRACe B304 TR Only for Base Version 6 1 SSDs n progress 6 2 mPCle n progress 6 3 OPT Plate n progress SD DT G45 0e Page 49 TRACe B304 TR User s Manual Chapter 7 Reference Information Reference Information 588 COMA 15840 7 EN 3 5 d MEE ZZ 7z Power Tum SD DT G45 0e Page 50 TRACe B304 TR User s Manual Reference Information 7 1 Mechanical 7 1 1 to mount a SSD Disk n progress 7 1 2 to integrate mPCle Module Two sizes and different types are available in the mPCle market mini PCI Express standards SLOT 1 PSU side both full and half sizes mini PCI Express Cards are supported But if you choose Full size the mini PCI Express Cardshall be F2 type mechanical restrictions SLOT 2 Mini PCI Express Card Full size only F1 or F2 types SLOT 3 preferred slot for MVB Mini P
50. em device presence Use cd command to reach directory where the Bios image will be stored Use 1s to display files list If BIOS wished image name is TRACe Vxxx SETUP ROM then dump the current BIOS image entering command fpt64 D TRACe Vxxx SETUP ROM Wait 20 seconds When finished without error then the BIOS ROM image is stored onto the USB device and ready to be flashed again SD DT G45 0e Page 43 TRACe B304 TR User s Manual Updating TRACe 4 1 3 Default BIOS Setting When a new BIOS is flashed it could be necessary to adjust the BIOS SETUP Here is the list of BIOS SETUP Modification done for TRACe production compared to the delivered COMe_mBT10 module BIOS image In case of doubt first restore the SETUP DEFAULT gt Boot restore SETUP DEFAULT Then gt Setup Advanced South Cluster Configuration Audio Controller Disable gt Setup Advanced South Cluster Configuration Miscellaneous Configuration State S5 State gt Setup Advanced South Cluster Configuration LPSS amp SCC Configuration SCC SD Card Support Use as GPIO Setup Advanced OS Selection Linux Security TPM Support Disable Boot 1 eMMC Card0 disk eMMC as first boot device Then Save and Exit 42 CPLD 4 2 1 Update The update can be done under Linux using the trace cpld update tool and a JEDEC file jed The update takes 3 seconds Do not power off while updating Then power cycle the system to start on t
51. es 3 Table 2 DC IN Pin Configuration 11 Table 3 LAN B LAN C Connectors Pin Configuration 12 Table 4 COM B COM C Connectors Pin Configuration 13 Table 5 GPIO Connector Pin Configuration 2 1 4 14 Table 6 Audio Connector Pin Configuration 1 15 Table 7 COM A Connector Pin Configuration eR 16 Table 8 Gigabit Ethernet Connector Pin 17 Table 9 USB 3 0 Connector Pin 18 Table 10 USB 2 0 Connector Pin 1 19 Table 11 SIM Connector Pin Assignment 1 20 Table 12 DisplayPort Connector Pin 21 Table 13 Ethernet LEDs Status Definition 29 Table 14 TRACe B304 TR Grounding 39 Table 15 Onboard SATA DATA Connectors 53 Table 16 Onboard SATA Power Connectors Pinout
52. figuration HMU TX GND COMe TX COMe RX GND HMU RX ont WN Table 7 Connector Pin Configuration HMU serial line on COM A default can be routed to COM B instead can be selected by the trace config tool UART TX HMUTX TX UART TX RX HMU RX RX UART RX RTS UART RTS is available on COM B only RS 232 mode HMU TX HMU TX TX HMU TX TX output of HMU is available on both connectors RX RX HMU RX RTS 1 RTS is available on COM B only RS 232 mode SD DT G45 0e Page 16 TRACe B304 TR User s Manual Getting Started with TRACe B304 TR 2 5 2 LANA Gigabit Ethernet Port The TRACe B304 TR have a Gigabit Ethernet port LEDs Figure 13 LAN A Gigabit Ethernet Connector Pin Assignment 10BASE T 100BASE TX 1000 TX TX VO 1 BI_DA 2 TX TX BI_DA 3 RX l RX DB 4 5 BI_DC 6 RX 1 RX BI_DB 7 BI_DD 8 BI_DD Shell Chassis Ground Table 8 Gigabit Ethernet Connector Pin Assignment Note The Ethernet transmission should operate using a CAT5 cable with a maximum length of 100 m N The Ethernet connectors are available as RJ 45 connectors with tab down SD DT G45 0e Page 17 TRACe B304 TR User s Manual Getting Started with TRACe B304 TR 2 5 3 USB B USB 3 0 Connector The TRACe B304 TR have a USB3 0 compliant connector It can work as a USB 2 0 connector or as a USB 3 0 connector
53. gure 2 TRACe B304 TR Front View 4 Figure 3 TRACe B304 TR Rear View 4 Figure 4 TRACe B304 TR Block Diagram 2 1 5 Figure 5 Identification Label Location 8 Figure 6 TRACe B304 TR Dimensions 2 10 Figure 7 DC IN Connector 11 Figure 8 LAN B LAN C Connectors 2 12 Figure 9 COM B COM C Connectors 13 Figure 10 GPIO 14 Figure 11 Audio Rh hh 15 Figure 12 A Connector 16 Figure 13 LAN A Gigabit Ethernet Connector 17 Figure 14 USB 3 0 Connector SE NBD eee ee eee eee 18 Figure 15 USB 2 0 Connector 9 TE 19 Figure 16 SIM Connector 7 20 Figure 17 DisplayPort Connector 21 Figure 18 Conne
54. he new cPLD version For example as root user root trace board trace cpld update w lt KBOX C304 TR PLD V3 jed 4 2 2 Default cPLD settings The saved settings configured by the trace config tool are loaded by the cPLD at power on from a non volatile memory However if these settings are changed and set to a value not suitable for the system it may not be possible to run trace config again to recover In this case the system must be started in debug mode by pressing the RESET switch on maintenance plate while powering on VDC applied and IGN on then by releasing the switch as soon some LEDs are switched on In this mode the saved settings are not loaded and the system is started in default configuration The Power status LED front plate and L5 maintenance plate are blinking green twice a second 2 Hz On maintenance plate L1 should be red and L2 green to indicate that the system is in the running state all PSUs started OK and reset released Then trace config can be run again to fix the configuration To restore saved settings to defaults in one command root trace board trace config r When done just power cycle SD DT G45 0e Page 44 TRACe B304 TR User s Manual Updating TRACe 4 3 Health Management Unit The microcontroller firmware implementing the HMU can be updated via the network interface LANC 4 3 1 Configuration for Updating HMU Firmware PC under Windows running the Microchip applicative softw
55. ions of cabling To power on the TRACe B304 TR Operational Box Computer you need to attach a Power Supply Cable refer to section 2 6 page 22 to the DC IN connector PSU wide range 24 VDC 110 VDC On the other side it has to be cabled to a DC power source 24 VDC minimum following the pin out description in the above section 2 4 I O Connectors Pintout page 11 Two methods 1 Graphical session recommended Connect a display for graphical session display and cables not provided to the DisplayPort on Maintenance side Plug a USB hub for keyboard and mouse in USB A connector on Maintenance side 2 Serial console Connect to the TRACe B304 TR via RJ 12 serial connector on maintenance side using a cable KIT 2X RJ12DB9 included in TRACE KIT CAB EVAL and use a serial terminal emulator as putty or minicom for example Power Supply E P 5 EH 7 MAINTENANCE L1 L2 L3 L4 L5 RST SIM CARDS e ISBA USBB LANA USB Key Serial Connector DisplayPort Figure 18 Connecting TRACe B304 TR SD DT G45 0e Page 23 TRACe B304 TR User s Manual Getting Started with TRACe B304 TR To start the system gt Power on the DC power supply module via DC IN connector section 2 4 I O Connectors Pintout page 11 and then turn on the ignition key As long as the ignition signal is not connected to the POWER IN power supply connector pin 1 the system cannot start
56. l Getting Started with TRACe B304 TR 2 2 System Identification An identification label is available on the left side of the system Label data gt Model TRACE B304 TR gt S N XXXX 4 digits chronologic Serial Number ECL 10000 5 digits Engineering Change Level Model TRACE B304 TR C Ht S N0004 10000 2 kontron 5 Figure 5 Identification Label Location Page 8 SD DT G45 0e TRACe B304 TR User s Manual Getting Started with TRACe B304 TR 2 3 Ata Glance Processor gt Intel Atom Bay Trail I Platform E3845 quad cores 1 91 GHz Memory gt 2GB DDR3 with ECC Storage EMMC 8 GB SLC Flash soldered Connectivity Operational side gt 2x M12 GbE 10 100 1000BASE T 2x Serial SUBD9 for RS232 422 485 gt 1x Audio SUBD9 gt 1x GPIO SUBD25 gt Maintenance side gt 1x USB high speed gt 1x USB 3 0 3 0 only port BIOS configurable gt 1x RJ 45 GbE 10 100 1000BASE T 1x RJ 12 RS 232 for processor and HMU Software Linux Refer to 7 6 1 2 COMe BSP page 59 Windows Refer to 7 7 Windows BSP page 65 Specific TRACe tools package and live demo image will be made available on TRACe Kontron Web Site download section Management gt Operational side status LED Power status LED Maintenance side Status an User LEDs gt L1 User1 L2 UserO L3 Alarm HMU L4 Sys SATA L5 Power Status SD DT G45 0e Page 9
57. lls attention to important features or instructions Caution this notice alert you to system damage loss of data or risk of personal injury This symbol indicates that product must be connected to earth ground prior making any other connections to the equipment ESD This banner indicates an Electrostatic Sensitive Device This symbol Indicates on the rating plate that the equipment is suitable for direct current only 24 VDC 110 VDC nominal Identify relevant terminals C The CE marking certifies that the product complies with the essential requirements of the Directive 2011 65 EC of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment 2006 95 CE of the European Parliament and of the Council of 12 December 2006 on the harmonisation of the laws of Member States relating to electrical equipment designed for use within certain voltage limits 2004 108 CE of the European Parliament and of the Council of 15 December 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility All numbers are expressed in decimal except addresses and memory or register data which are expressed in hexadecimal The prefix shows hexadecimal number following the C programming language convention The multipliers M and G have their conventional scientific and engineering me
58. m ES E O0 Display 0 Display 1 Display DP MiniPCle MiniPCle MiniPCle Figure 22 TRACe as a Box PC SD DT G45 0e Page 31 B304 TR User s Manual Getting Started with TRACe B304 TR 2 9 2 TRACe as a monitored Operational Computer PSU 50155 SATA 0 SATA 1 4 Processor Intel Atom Health Management JTAG Display 0 Display 1 RTC Display DP Health Management And Or Health Management gos MiniPCle b MiniPCle MiniPCle Figure 23 TRACe as a monitored Operational Computer Refer to section 7 5 Healh Management Unit page 56 for more detailed information about HMU SD DT G45 0e Page 32 TRACe B304 TR User s Manual Getting Started with TRACe B304 TR 2 10 Linux Linux BSP COMe mBT10 Linux BSP Document Revision 010 In addition to the standard Linux distribution some TRACe specific software is provided BSP gt Drivers trace cpld cPLD driver gt trace cpld i2c bus driver for the 2 bus managed by the cPLD dev i2c 24 trace cpld micro driver for communication with HMU trace cpld event driver to manage events ignition signal Services trace poweroffd daemon managing ignition signal to do an automatic shutdown when switched off gt trace shutdown script
59. n to cover as far as possible the range of people who will handle or use the TRACe B304 TR system from unpackers inspectors through system managers and installation technicians to hardware and software engineers Most chapters assume a certain amount of knowledge on the subjects of single board com puter architecture interfaces peripherals system cabling grounding and communications 1 1 3 Scope This manual describes all variants of the TRACe B304 TR series 1 1 44 Structure This manual is structured in a way that will reflect the sequence of operations from receipt of the system up to getting it working Each topic is covered in a separate chapter and each chapter begins with brief introduction that tells you what the chapter contains In this way you can skip any chapters that are not applicable or with which you are already familiar The chapters are Chapter 1 Introduction this chapter gt Chapter 2 Getting Started with TRACe Chapter 3 Deploying TRACe Chapter 4 Updating TRACe Chapter 5 Getting Help Chapter 6 Customizing TRACe B304 TR gt Chapter 7 Reference Information wo v w Appendix A References w Appendix B List of Abbreviations SD DT G45 0e Page 2 TRACe B304 TR User s Manual Introduction 1 2 B304 TR Overview 1 2 4 Main Features Kontron TRACe B304 TR is an EN50155 certified fanless operational computer This B version is specifically designed to ease c
60. ns fan fan functions gen general functions gpio gpio functions i2c i2c functions mem memory functions net network info functions pci pci info functions perf performance functions smbus smbus functions Spi spi functions temp temperature sensors functions volt voltage sensors functions watchdog functions To learn more about class args ktool API class h The Wake up from Suspend is supported under Windows see section 2 7 1 Plug Suspend the system iN page 23 7 7 2 Features not yet supported by Windows BSP The following features are not yet supported by Kontron Windows BSP w MicroController HMU communication Non standard SPI communication Alarm Management IRQ10 event LM73 3 temperature sensors Specific CPLD access for Board Controlling the services available with the Linux command Trace config are not yet adapted for Windows COM B and COM C or driver for XR17V354 Pcie UART but driver is available on www exar com SD DT G45 0e Page 66 TRACe B304 TR User s Manual Reference Information 7 8 System 7 8 1 Power Management POWER IN Isolated GND POWER IN Isolated GND ING KEY Protected Earth IO BOARD 500ms 500ms gt START delay Programmable OFF delay Figure 32 Ignition Implementation SD DT G45 0e Page 67 TRACe B304 TR User s Manual 7 9 Standards Compliance The TRACe
61. on maintenance side HMU request SD DT G45 0e Page 24 B304 TR User s Manual Getting Started with TRACe B304 TR 2 7 2 Play gt Plug the system as described in section 2 7 1 Plug page 23 gt Power on the system in graphical session mode monitor and keyboard gt A Linux Fedora 20 login prompt should appear a few seconds gt Choose one of the three following user s accounts to log in Root Account Administrator gt login root gt password kontron Tech Account Super User login tech password kontron Guest Account Guest User gt login guest password guest TRACe configuration Some configuration settings are available under BIOS setup however TRACe specific settings are managed by the OS tool trace config By default this tool works on saved settings that are applied at power on ignition signal on It is also possible to work on the current settings to temporarily change some settings changes are lost at power off command must be run as root user N To display saved settings root trace board trace config Saved configuration serial 232 RS232 mode on COM B COM C serial lines serial full Full duplex on COM B COM C serial lines tpm on Second TPM chip ON start Start when ignition key is switched ON dport maint DisplayPort on maintenance plate connector sata minil SATA interface to mini socket
62. ormation B connector for microcontroller console socket 0 PCIe device present socket 0 PCIe device NOT present socket 1 device present mPCIe or mSATA socket 1 device NOT present mPCIe or mSATA socket 1 SATA device present socket 1 SATA device NOT present socket 2 PCIe device present socket 2 PCIe device NOT present SYS red OFF SYS red ON ALARM red OFF ALARM red ON USER1 is OFF USER1 is RED USER1 is GREEN USER1 is AMBER USERO is OFF USERO is RED USERO is GREEN USERO is AMBER 7 6 3 2 trace cpld update cPLD Update Tool Carrier Board root trace board trace cpld update trace cpld update cPLD update utility h r y w gt Examples Help Check image in cPLD is valid Convert a jed file from stdin to a binary to stdout Readback cPLD in binary format to stdout Verify that image in cPLD matches the jed file from stdin Program cPLD from jed file from stdin trace cpld update c trace cpld update trace cpld update trace cpld update trace cpld update root trace board SD DT G45 0e j lt file jed gt file bin r gt readback bin v lt file jed w lt file jed Page 62 TRACe B304 TR User s Manual Reference Information 7 6 3 3 trace poweroffd trace shutdown script These scripts located in usr local bin are used to implement an automatic system shutdown when the ignition signal is switched off The trace poweroffd script should be use
63. ossibly available through the graphics driver and ACPI Bootcounter kontron bootcounter driver to access the board internal bootcounter through the sys file system Embedded EEPROM User Area kontron eeep driver to access the persistant data storage within the configuration EEPROM nct7802 driver Driver to access the hwmonitor on the module It is packaged through several RPM files gt kontron ci noarch rpm Kontron specific modifications to the base system Theme changes Driver configuration System configuration kernel mvv1 x86 64 rpm Product specific kernel and kernel development packages for 64 bit systems SD DT G45 0e Page 59 TRACe B304 TR User s Manual Reference Information gt kernel mvv1 i686 rpm Product specific kernel and kernel development packages for 32 bit systems perf x86_64 rpm Product kernel specific performance counter tools for 64 bit systems gt perf i686 rpm Product kernel specific performance counter tools for 32 bit systems gt python perf x86 64 rpm Product kernel specific performance counter support module for 64 bit systems gt python perf i686 rpm Product kernel specific performance counter support module for 32 bit systems kernel bhl6 src rpm Product specfic kernel source package kontron ci src rpm Source package for the Kontron specific modifications to the base system 7 6 1 3 TRACe Specific Drivers Four modules are provided for a full
64. refer to Figure 9 Ignition Implementation page 13 gt A Linux login prompt should appear in a few seconds The system can also be configured to stay off when ignition signal is switched on and start on assertion of GPIO IN 0 or GPIO IN 1 configurable using trace config or on HMU request In this case when waiting to start the Power status LED is flashing twice every 2 seconds To stop the system Manual method Shutdown the OS with shutdown menu in graphical session or halt command in a Linux terminal for example When the Power status LED is flashing once every 2 seconds shutdown completed switch off the ignition signal You can also optionally remove power on POWER IN Automatic method default This requires the trace poweroffd daemon to be started when the OS is booting in a Linux console Just switch off the ignition signal this automatically performs a shutdown and once the shutdown is completed a power off Suspend the system Suspend the OS with suspend menu in graphical session or systemctl suspend in a Linux terminal as root The Power status LED is flashing once every 2 second To resume the following methods are supported Switch the ignition signal off and on fastly less than 750mS Send a Wake On Lan Ethernet packet to the system on LAN B or LAN C interfaces Assertion of a GPIO IN 0 or GPIO IN 1 configurable using trace config Reset switch
65. rove this document or the product described herein as seen fit by Kontron without further notice Trademarks This document may include names company logos and trademarks which are registered trademarks and therefore proprietary to their respective owners Environmental Protection Statement This product has been manufactured to satisfy environmental protection requirements where possible Many of the components used structural parts printed circuit boards connectors batteries etc are capable of being recycled Final disposition of this product after its service life must be accomplished in accordance with applicable country state or local laws or regulations Environmental protection is a high priority with Kontron Kontron follows the DEEE WEEE directive You are encouraged to return our BS products for proper disposal The Waste Electrical and Electronic Equipment WEEE Directive aims to gt reduce waste arising from electrical and electronic equipment EEE gt make producers of EEE responsible for the environmental impact of their products especially when they become waste gt encourage separate collection and subsequent treatment reuse recovery recycling and sound environmental disposal of EEE gt improve the environmental performance of all those involved during the lifecycle of EEE SD DT G45 0e Page ii Preface TRACe B304 TR User s Manual Conventions N lt ote Note this notice ca
66. support of the TRACe system gt trace cpld cPLD driver gt trace cpld i2c Bus driver for the I2C bus managed by the cPLD trace cpld event Driver to manage events ignition signal trace cpld micro Driver for communication with HMU Non standard SPI protocol 7 6 2 Network Configuration Network configuration is done with the legacy network service through configuration files under etc syscon fig network script directory LAN A Eth2 192 168 1 1 LAN B EthO Not configured LAN C Eth1 Not configured In order to configure a WIFI module the service NetworkManager shall be used instead of network one Use the following command lines through a terminal systemct stop network systemct disable network systemct unmask NetworkManager systemct l enable NetworkManager systemct start NetworkManager SH SH SHR Now the network can be configured with a graphical windows SD DT G45 0e Page 60 TRACe B304 TR User s Manual Reference Information 7 6 3 Tools 7 6 3 1 trace config TRACe Configuration Tool root trace board trace config h Usage trace config OPTION TRACe configuration tool V1 5 Options h help Get help c current Work on current settings volatile runtime settings instead of default behaviour that is to work on saved settings non volatile default settings s Saved To be used with current to also work on saved settings in addition to current settings
67. uration 61 7 6 3 2 trace cpld update cPLD Update Tool Carrier Board 62 7 6 3 3 trace poweroffd 1 63 D MMS RET mr 63 7 6 4 1 devices MEBBU 1 NM ees ooo eet RR REL RITE En EEG 63 7 6 4 2 LAN QA IRISH 63 7 6 4 3 GPIOS 7 BERI eee A RII 63 7 7 Windows MEME AEN 65 7 7 1 Feature supported by BSP 65 7 7 2 Features not yet supported by Windows BSP 66 7 8 Wene 67 7 8 1 Power Management 67 7 9 Standards Compliance 68 Appendix A 69 A 1 Associated Documentation 69 A 2 Accessories References Examples 69 Appendix B List of Abbreviations 70 SD DT G45 0e Page viii Table Of Contents TRACe B304 TR User s Manual List Of Figures Figure 1 TRACe B304 TR Overview 1 1 0 1 Fi
68. ustomization thanks to MiniPCie slots and multiple configuration extensions to help integrators meet application specific requirements The B304 TR version is based on a COM Express CPU module featuring intel Atom E3845 Bay Trail quad core 1 91 GHz The TRACe B304 TR is designed to ensure stable operation in harsh environments The Kontron TRACe B304 TR features a wide range power supply from 24 VDC to 110 VDC Its front plate is dedicated to the operational connectors certified I O according to EN50155 standard Ethernet serial ports audio digital inputs and outputs whereas the rear plate hosts maintenance connectors DisplayPort USB serial Ethernet On this plate a reserved area with 3 pre holes allows the routing of non provided Mini PCi exp ress cards I O signals GSM GPRS 3G LTE 4G GPS WiFi Bluetooth Kontron TRACe B304 TR extensible and modular design allows custom configuration on operational front plate an option plate is available for additional interfaces MVB CAN Layer2 CAN Open Profibus TRACe B304 TR has been designed to support a comprehensive health management capability thanks to sensors and a microcontroller for system health monitoring The integrated Hearth Management Unit HMU monitors boards and inbox ambient temperature voltages current and even manages Vital Product Data P N S N E C Level of main components Health Management by Kontron covers all the vital resources of TRACe B304 TR to
69. y when handling or unpacking the product Please consult the special handling and unpacking instruction Page v SD DT G45 0e TRACe B304 TR User s Manual Table Of Contents Table Of Contents Chapter 1 Introduction seio xx ore E EE EX Ee UDCEE ERR E ELE 1 1 4 2 141 ODECE o tre trs tret 2 1 1 2 A 2 11 3 S60pG6 a mee uses eR ede Rb RI 22 22 2 1 1 4 2 1 2 B304 TR Overview 3 1 2 1 Main Features 3 1 2 2 Ordering NEED eee 3 1 2 3 Introducing Operational and Maintenance Side Views 4 1 2 4 Block Diagram ERE 5 1 8 Environmental Specifications 41 6 Chapter 2 Getting Started with TRACe 304 7 2 4 Receipt of the Equipment 7 2 1 41 Checking the Packages