Contents
1. 3 2 Typical Multi Story or Split Level House Install a wireless smoke detector on the ceiling or wall inside each mr bedroom and in the hallway outside each separate sleeping area If a bedroom area hallway is more than 9 meter long install a wire less smoke detector at each end Please install a wireless smoke detector on the top of a first to second floor stairwell CY gt ka Xa Bedroom Bedroom LEGEND Minimum required smoke detector locations ZS C Recommended additional smoke detector locations In Living Dining Room Room Basement 3 3 Incorrect EWF1 Placement DO NOT place EWF1 in the following locations Near appliances or areas where normal combustion regularly occurs kitchens near furnaces hot water heaters Use specialized wireless smoke detector with unwanted alarm control for this areas In areas with high humidity like bathrooms or areas near dishwashers or washing machines Install at least 3 meters away from these areas Near air returns or heating and cooling supply vents Install at least 1 meter away from these areas The air could blow smoke away from the detector interrupting its alarm In rooms where temperatures may fall below 5 C or rise above 45 C e _Inextremely dusty dirty or insect infested areas where loose particles interfere with wireless smoke detector operation geile Inco
2. button and the wireless smoke detector will sound a loud beep The alarm will stop sounding after releasing the TEST button When testing EWF1 using ELDES Configuration Tool software the detector will provide short beeps e Stand at arm s length from the wireless smoke detector when testing e _ Test wireless smoke detectors weekly and upon returning from vacation or when no one has been in the household for several days e Test each wireless smoke detector to be sure it is installed correctly and operating properly e DONOT use an open flame to test this wireless smoke detector You may ignite and damage the wireless smoke detector or your home e Ifthe wireless smoke detector does not sound please check the battery and signal level using ELDES Configuration Tool software vedas bile 8 Test all wireless smoke detectors weekly to ensure proper operation 5 2 Battery Replacement 1 Turn EWF1 counter clockwise to detach it from the mounting 7 plate BZ 9V battery Gently pull down the wireless smoke detector Remove the old battery from the battery pocket Postition the new 9V battery according to the appropriate battery slot positive negative terminals indicated on the enclosure of EWF1 Ensure the plastic battery holder is fully depressed when the battery has been fitted 5 Using the TEST button test the wireless smoke detector to verify if itis operational See 4 1 Testing EWF1 6 Re attach the
3. a Ill a eldes F User Manual v1 0 Compatible with e ESIM264 v7 11 30 and up EWT1 16 14 and up e ESIM364 v02 04 01 and up e EPIR2 v01 01 02 and up Main Features Photoelectric sensor for slow smouldering fires Quick fix mounting plate for easy installation e TEST button LED operation indicator Built in speaker for audio alarm indication Auto reset when smoke clears Non radioactive technology for environmental friendly High and stable sensitivity EWF1 is a wireless photoelctric type smoke detector intended to use with ELDES alarm systems Photoelectric smoke detectors are gener ally more effective at detecting smouldering fires which smoulder for hours before bursting into flame An optical method is used for the detection of visible smoke When the concentration of smoke in the optical chamber exceeds a given threshold EWF1 sounds the alarm and sends out a signal to the ELDES alarm system using the wireless connection and the system triggers the alarm By default when more than one EWF1 device is used the system will automatically activate the interconnection feature See 4 1 Interconnection ESIM264 and EPIR2 alarm systems support up to 16 EWF1 devices while ESIM364 up to 32 EWF1 devices The maximum wireless con nection range is 150 meters in open areas 1 PACKAGE CONTENT qty 1 qty 1 qty 1 ww qty 2 2 TECHNICAL SPECIFICATIONS 2 1 Electrical amp Mechanical Characteri
4. g and holding the TEST button Please ignore the sound 5 4 Cleaning Clean the wireless smoke detector at least once a month to remove dust dirt or debris Using the soft brush or wand attachment of a vacuum cleaner vacuum all sides and cover of wireless smoke detector Be sure all the vents are free of debris If necessary use a damp cloth to clean wireless smoke detector cover ALLL Do not attempt to remove the cover to clean inside the wireless smoke detector This will void your warranty EN EWF1 Manual v 1 0 6 ADDITIONAL INFORMATION Limited Liability The buyer must agree that the system will reduce the risk of fire theft burglary or other dangers but does not quarantee against such events ELDES UAB will not take any responsibility regarding personal or property or revenue loss while using the system ELDES UAB liability according to local laws does not exceed value of the purchased system ELDES UAB is not affiliated with any of the Internet pro viders therefore is not responsible for the quality of Internet service Manufacturer Warranty This device carries a 24 month warranty by the manufacturer ELDES UAB Warranty period starts from the day the system has been purchased by the end user The warranty is valid only if the system has been used as intended following all guidelines listed in the manual and within specified operating conditions Receipt must be kept as a proof of purchase date The warranty
5. is voided if the system has been exposed to mechanical impact chemicals high humidity fluids corrosive and hazardous environment or other force majeure factors Safety instructions Please read and follow these safety guidelines in order to maintain safety of operators and people around _ DO NOT use the system where it can be interfere with other devices and cause any potential danger e DO NOT use the system with medical devices e DO NOT use the system in hazardous environment e DONOT expose the system to high humidity chemical environment or mechanical impacts e DONOT attempt to personally repair the system the product must not be disposed of together with household waste To prevent possible harm to human health and or the environment the product must be disposed on in an approved and environmentally safe recycling process For further infor mation on how to dispose of this product correctly contact the system supplier or the local authority responsible for waste MEE disposal in your area Dd The WEEE Waste Electrical and Electronic Equipment marking on this product see left or its documentation indicates that Copyright ELDES UAB 2013 All rights reserved zation by ELDES UAB ELDES UAB reserves the right to update or modify this document and or related products without a warning Hereby ELDES UAB declares that wireless smoke detector EWF1 is in compliance with the essential requirements and o
6. ke detectors in every house no matter how small the house is 3 Install a wireless smoke detector in each room that is divided by a partial wall either coming down from the ceiling at least 20 centim eters or coming up from the floor 4 Install a wireless smoke detector in lived in attics or attics which ho use electrical equipment like furnaces air conditioners or heaters ALLL For best protection we recommend that you install a wireless smoke detector in every room Recommended EWF1 placement locations a Ceiling 01 m I 1 Acceptable ye 0 1 m Max here NEVER HERE Top of detector acceptable here 09m 3ft 09m Bft HORIZONTAL DISTANCE wall AHH Measurements shown are to the closest edge of the detector 3 1 Typical Single Story House Install a wireless smoke detector on the ceiling or wall inside each bedroom and in the hallway outside each separate sleeping area If a bedroom area hallway is more than 9 meters long install a wireless smoke detector at each end If there is a basement Install a wireless smoke detector on the basement ceiling at the bottom of the stairwell H Bedroom O Bedroom Living Room O O Family Room 7 LJ Minimum required smoke O LEGEND Bedroom A Dining Room Kitchen detector locations O Recommended additional smoke detector locations EWF1 Manual v 1 0 E
7. on as well as Battery Level and Signal Level see Fig No 6 10 EWF1 wireless smoke detector is ready for use au Mounting plate Mounting slot Screws 1 Battery pocket door ALHA If you are unable to bind the wireless device please restore the parameters of the wireless device to default and try again See chapter 5 3 Restoring Default Parameters for more details EWF1 Manual v 1 0 g Zone Tamper Alarm Quege Wireless Device Management Device ID 58122812 A EWF1 0D 02000011 Tamper ALARMI CA ERD Soks Nesli Nets Device Type EWF1 CONNECTED Search me Temperature 30 C Battery Level 0 Signal Level 0 Device ID x nn Be 4 1 Interconnection The interconnection feature automatically links all wireless smoke detectors to each other that are connected to the same alarm system unit When any EWF1 detects smoke it sounds the alarm and sends the signal to the alarm system that causes an instant alarm along with the rest of EWF1 wireless smoke detectors The device that detected smoke will auto reset when the smoke clears while the rest of EWF1 detectors will sound according to the set time period by default 60 seconds By default the interconnection feature is enabled but can be disabled using ELDES Configuration Tool software 5 MAINTENANCE 5 1 Testing EWF1 e The TEST button verifies if EWF1 is operational Firmly push the TEST
8. rrect placement will result in a decrease of operational effectiveness 4 INSTALLATION 1 Detach the mounting plate by turning it counter clockwise from he back of EWF1 see Fig No 5 2 Secure the mounting plate to ceiling or wall with mounting screws see Fig No 5 3 Lift to open the battery pocket door see Fig No 7 4 Insert the battery into the battery pocket considering the po larity terminals indicated on the enclosure of EWF1 Ensure the battery is securely connected Red LED may flash briefly when he battery is being installed Close the battery pocket door by snapping it into place Position the smoke detector to the mounting plate by turning it clockwise to lock into place Note that the device will not lock into the mounting plate without the battery being present in he battery pocket 7 Push the TEST button to verify if the wirless smoke detector is operational See 4 1 Testing EWF1 8 Bind the device to the alarm system using ELDES Configuration Tool software Open Wireless Device Management section and enter a 8 digit wireless device ID located on the EWF1 enclosure and click the Add button see Fig No 6 The device can also be bind by sending a corresponding command via SMS text message For more details please refer to the software s HELP section and ELDES alarm system installation manual 9 Upon the successful binding process EWF1 device icon be comes visible in Wireless Device Management secti
9. stics Detection Type Photoelectric chamber Alarm Sound Level 85 Decibels at 3 meters Battery Voltage gy Battery Type 6F22 primary alkaline Number of Batteries 1 Battery Operation Time 18 months Wireless Transmitter Receiver Frequency 868 Mhz Wireless Communication Range Up to 30 meters in premises up to 150 meters in open areas Range of Operating Temperatures 5 C to 45 C Humidity 0 90 RH 0 40 C non condensing Sensitivity to Smoke 3 0 6 0 Obs m Dimensions 110mm Compatible with Alarm Systems ELDES Wireless This operation time might vary in different conditions 2 2 Main Unit amp LED Functionality TEST Button for testing button for testing and restoring default parameters if RESET button not available LED EWF1 status indication SIREN Built in speaker for audio alarm indication RESET Button for restoring default parameters TEST button foe RESET button or BATTERY LED indicator Unavailaible on some EWF1 models 2 EN EWF1 Manual v 1 0 3 PLACEMENT 1 Install the wireless smoke detector as close to the center of the ceiling as possible If this is not practical mount no closer than 10 centimeters from a wall or corner Also if local codes allow install wireless smoke detectors on walls between 10 and 30 centimeters from ceiling wall intersections 2 Install a minimum of two wireless smo
10. ther relevant provisions of Directive 1999 5 EC The declaration of conformity may be consulted at www eldes lt EWF1 Manual v 1 0 g Itis not allowed to copy and distribute information in this document or pass to a third party without advanced written authori C Made in the European Union www eldes lt
11. wireless smoke detector to the mounting plate by turning the wireless smoke detector clockwise until it snaps into place EWF1 Manual v 1 0 Vay wile Only 9V 6F22 primary alkaline type battery can be used Install only new high quality and unexpired batteries Va wile The battery must be removed if the device is not in use Lute In order to avoid fire or explosion hazards the system must be used only with approved battery Special care must be taken when connecting positive and negative battery terminals Dispose old batteries only into special collection sites Do not charge disassemble heat or incinerate old batteries ALLA The battery status can be monitored in real time using ELDES Configuration Tool software bled The system sends an SMS message to the preset user phone number as soon as the battery level runs below 5 5 3 Restoring Default Parameters 1 Remove the battery from EWF1 2 Press and hold the RESET button 3 Insert the battery back to EWF1 4 Hold the RESET button until you hear a short beep 5 Release the RESET button On some EWF1 models the RESET button is not available On such EWF1 devices the reset process is as follows 1 Remove the battery from EWF1 2 Wait for 45 seconds 3 Press and hold the TEST button 4 Insert the battery back to EWF1 5 Hold the TEST button for 10 seconds or more 6 Release the TEST button GUANI EWF1 built in speaker will sound while pressin
Download Pdf Manuals
Related Search
Related Contents
取扱説明書等 N`oubliez pas de parler de Dynamique et de la Cvthèque à vos AQUABAC™ II XT Specimen Label 取扱説明書 - D.speed APC LE600I uninterruptible power supply (UPS) Manual de instalación VNC [北浦和駅市民の窓口(浦)]基準表(PDF形式:33KB) Captadores Solares ENDA ETC4420 PID TEMPERATURE CONTROLLER Copyright © All rights reserved.