Integra32 User Manual
Contents
1. 45 BOSCH ALARM PANEL INTERFACE eave ivi tele ved tei ie ho did iere 46 SUMMIT ALARM PANEL INTERFACE 48 APPENDIX DIALUP MODEM CONFIGURATION ssscccssssscssssssccssssccccssssccsessscccesscccessssccccsssaccessscsccssnee 51 REMOTE SITE MODEM RE nmn ann n nU 51 SERVER HOST SITE MODEM Raga tan ae ante Geek KORA REA Ae A AAAS s 52 MODEM CONNECTION re nene nnn 60 Integra32 Hardware Guide RBH Access Technologies Inc Chapter 1 Introducing Integra32 Chapter 1 Introducing Integra32 The Integra32 system from RBH Access Technologies Inc represents the latest in access technology specifically designed for smaller applications Its intuitive graphical interface allows users to take advantage of the power of the Integra32 with a minimal amount of training The IRC 2000 Intelligent Field Panels utilize flash firmware for easy upgrades The IRC 2000 panel uses fully distributed intelligence for off line operations In addition to supporting two card readers each IRC 2000 Intelligent Field Panel also has eight fully supervised alarm inputs along with eight outputs four dry contact outputs and four open collector outputs The IRC2000 s memory has been increased to now hold 5 000 cards and can be further extended to hold 8 000 cards An alternate panel the URC 2000 can be used along with or
2. Figure 6 modem Query results The modem failed to respond Make sure it is properly connected and turned If it is an internal modem or is connected verify that the interrupt For the port is properly set Figure 7 Modem Query error message RBH Access Technologies Inc Integra32 Hardware Guide 57 1 Specification Sheets Cautions Procedure for Modems connection 1 Dipswitch 8 of all IRC 2000s should be set to OFF before making the modem connection 2 After establishing the modem connection download to all IRC 2000s and not just the IRC 2000 to which modem is connected so that the password is downloaded to all the panels 3 Change all Dipswitch 8s to ON 4 Re power the IRC 2000s Configure Modem COM Port on the Integra32 Server 1 Open the Network Properties window in the Integra32 Database Manager Network Properties Advanced Port Type Modem Network m Poll Retries nc Network Time Out 11000 Milli Secs PC Modem Modem es 2 Standard 33600 bps Modem 3600 Phone 7654351 Schedule v Hang up After 3 Min Panel Modem Phone 765431 6 Password Init String EOF1 S0 1Y08 amp C18D0 amp HO amp R18 amp 51HO 2 Click on Port Type and select Modem Network 3 Use the Modem combo box down arrow and select the modem from those already setup under Windows 4 Set the baud rate 9600 and Phone number for the software to call the remote si
3. RR ees 9 URE 2000 iiie tee ertet Een 16 RTE iiie See Request to Exit Run LED 11 Integra32 Hardware Guide 42 5 Specification Cable RR RERUMS 40 ELC OS hehe 39 2000 36 PC 100 5 gei ee 38 URC 2000 neutri PIS 37 Status LED s Elevator Control 22 IRG 2000 ipeo erp 11 URC 2000 eite hee 17 Switching Inductive Devices esses 29 T TCP IP 1 ai 9 U Unlocked Mode ttt ter 32 URC2000 Connection Daigram 34 Connection Details eese 13 DIP Switch Settings oerorrrnrrrorvrnvnnrnvernvrrnrrrnrver 15 FUSES PE 17 Jumpers eene reete 17 PC deiode 13 RS485 16 Run LED needed 17 Specification eei eere 37 Stat s EBD S iet t eet err etes 17 Wiring 14 RBH Access Technologies Inc License amp Warranty License amp Warranty Notice 1 01 This Software is licensed not sold It is licensed to sublicenses including end users without either express or implied warranties of any kind on an is basis RBH Access Technologies Inc makes no express or implied warranties to sublicenses including end users with regard to this software including merchantability fitness for any purpose
4. Door Normal 5 Back Door Normal 6 Front Window Normal 7 Side Window Normal 8 Back Window Abnormal 9 Front Hall Restore 10 Living Room Restore 11 Kitchen Restore 12 Upstairs Hall Restore 13 1st Bedroom Door Abnormal 14 1st Bedroom Wind Abnormal 15 2nd Bedroom Restore RBH Access Technologies Inc Integra32 Hardware Guide 45 1 Specification Sheets Some inputs such as smoke detectors are always armed so they will only be able to display Restore or Alarm Inputs such as Entry types are delayed so that at first they will display the disarmed states Normal and Abnormal followed by Alarm if the timed entry fails In order to display a partition s status a database has to be created to store the zone names and its partition reference Bosch Alarm Panel Interface It is recommended that the user be familiar with the DS7400Xi panel and has the ability to program PIN codes and parameters into the panel The PC100 interface has been designed to connect the Integra network to the DS7400Xi alarm panel through the option or keypad bus It will emulate a keypad when a link has been provided and report status to the Integra network when included in the list of keypads If you observe the red and green led associated with the keypad network you should notice the red LED flashing as it receives data and the green LED flashing as it responds to polls The response to polls will only occur under the following conditions 1 The keypad add
5. Elevator Control see 19 IRC 2000 tege IER Deere 2 PC 100 21 URCZ2000 iot Une tete 13 Connection Diagram Controller Network eese 10 Door Strike eicere 31 Electronic Output sese 29 Handicap Output sese 31 IRC 2000 ettet tee 33 Magnetic LOCKk 4 i eee iet iet 30 Controller Addressing eese 5 15 Controller Networks 10 D DC utet uti See Door Contact Diagnostic LED 11 Switch Settings IRC 2000 5 2000 aeo Eee s 15 Door Contact rire IR EFE 23 Door Held Open Alarm eee 32 Door Held Open Warning eese 32 Door Strike Connection Diagram 31 E 4 15 ELC 08 Specification see 39 Electronic Output Connection Diagram 29 Elevator Control 18 Connection Details eee 19 Jumpers isset eaa edges 22 RBH Access Technologies Inc Specifications Status LED E E 22 Exit Reader Interface 33 Fire Signal eee ee 20 Fuses IRG 2000 RENDIR 11 URC 2000 rettet et et eiS 17 G General Purpose l put ida eet ice t etes 23 Outp t 28 H Handicap Output esee 28 Connection Diagram eee 31
6. is already armed the command will be ignored The key switch functionality works on the basis of a momentary contact Whenever the button is pushed the alarm panel will change states if possible when the switch returns to its closed position It is not allowed to arm if an exterior zone is open for example Each zone can be programmed manually through the keyboard interface There are two types of arming allowed STAY and AWAY RBH Access Technologies Inc Integra32 Hardware Guide 48 1 Specification Sheets Sharing a door contact It is possible to use the door contact of the access control system to be mapped to the door contact of the alarm panel as long as the reporting for the door contact is enabled by software Using Alarms Three types of alarms with A or B readers are allowed alarm reader alarm reader Forced entry reader Forced entry reader Reader Tamper Reader tamper Multiple Combinations For multiple combinations of inputs outputs and events a spare output on an IRC panel can be assigned this functionality through the use of links The output can be assigned to a Summit input and instructed to follow RBH Access Technologies Inc Integra32 Hardware Guide 49 1 Specification Sheets Power 9 14vdc IRC2000 Network Computer Connection RBH e CANAD
7. one hundred and twenty eight time zones as well as handicap access by cardholder High security and lock unlock modes are also supported Each panel can have up to sixty four input output links and the system is capable of holding two hundred and fifty five pre programmed operator commands Both local and timed Antipassback are also supported RBH Access Technologies Inc Integra32 Hardware Guide 1 Chapter 2 Intelligent Field Panel Chapter 2 Intelligent Field Panel IRC2000 The Integra32 access control system consists of one or more controllers information required by the controller is downloaded from the PC and stored locally in flash memory This information includes configuration data cardholder records access levels schedules and all other records necessary for the operation of the system The controller operates independent of the PC and all decision making is performed locally even in the event of total power loss while operating on battery backup Connection Details Power The IRC 2000 requires 9 to 14 volts DC and draws about 250ma PC Modem Interface Inputs Outputs Readers The PC Modem interface connects the IRC 2000 to a PC or modem through an RS232 TCP IP Ethernet or an RS485 2 wire interface There are two common terminals for each set of four inputs one between inputs one and two another between three and four one between five and six and one between seven and eight Seven diff
8. or non infringement of patents copyrights or any other proprietary rights of others RBH Access Technologies Inc shall not have any liability or responsibility to sublicenses including end users for damages of any kind including special indirect or consequential damages arising out of or resulting from any program services or materials made available hereunder or the or the modification thereof Notice 1 02 RBH Access Technologies Inc makes no claim or warranty with respect to the fitness of any product or software for a specific application and assumes no responsibility for installation This warranty is in lieu of all other warranties expressed or implied No representative or agent of RBH Access Technologies Inc may make any other claims to the fitness of any product for any application RBH Access Technologies Inc Integra32 Hardware Guide 43 1 Specification Sheets Appendix A PC 100 Interface Applications The PC 100 communications interface can be used for a number of different applications PC 100s can be used to interface alarm panels with the Integra TM system Some DSC Bosch Summit Gardtec Rokonet and Paradox alarm panels can be interfaced this way Wiring Power Computer 9 14vdc Connection Integra32 Network Connection connection The PC 100 connects to the IRC 2000 through the RS 485 Power 9 14 150ma LEDs DIAGI Interface status DIAG2 Inte
9. the shields of all reader and communication cables back to one location Do not connect them to the panel or the panel s housing Grounding the Integra32 system RS 485 Earth To PC RS 232 Ground 12vdc 12vdc 16vac 16vac External External Transformer Transformer AC Power Source Integra32 Hardware Guide RBH Access Technologies Inc 4 Chapter 2 Intelligent Field Panel DIP Switch Settings The IRC 2000 s DIP switches control a number of operating parameters including the device address and serial port baud rate The controller must be powered down to accept any changes in the DIP switch settings Use DIP switches one through five to set the controller address Switches six and seven set the communication baud rate and switch eight is used to set the connection type modem or direct DIP Switch 8 Modem Direct PC Connection Controller Addressing Use DIP switches 1 2 3 4 and 5 to select the controller address The address is binary coded and the switch settings for all sixteen possible addresses are given below Controller Addressing Off Off Off Off Off Off Off Of On On Of Of 6 Off Off Of Of On Of 8 E NN Off Off Off RBH Access Technologies Inc Integra32 Hardware Guide 5 Chapter 2 Intelligent Field Panel Direct Connect Modem Selection DIP switch 8 specifies whether the IRC 2000 is connected directly to a serial port on the PC or communicates with the
10. time as the Lock Output and is used to bypass the door contact of a burglar alarm panel The Alarm Shunt Output will reset with the closure of the access control panel s door contact the Alarm Shunt Output will stay activated past the Unlock Time as long as the door is open door with two contacts one for the burglar Alarm and one for the access control will require an Alarm Shunt Output to prevent the burglar alarm system for going into alarm during a valid entry Modem Power Output The Modem Power Output is a normally activated output that is used to reset a modem by momentarily removing the power from the modem General Purpose Output General Purpose Outputs are outputs that are user controlled They are activated and de activated by user defined links and schedules Integra32 Hardware Guide RBH Access Technologies Inc 28 Chapter 3 Input amp Output Connections Electronic Output Connection Diagram The electronic outputs are capable of switching up to 100ma to ground Piezo Buzzer 12vdc Power Supply Switching Inductive Devices Locks Bells Exercise caution when switching an inductive load Inductive devices include external relay solenoids bells and door locks of these devices generate extremely high voltage spikes several thousand volts when power is applied or removed and possible disruption of the operation could occur if this interference gets on to the electronic circuit board T
11. 0 will automatically reset the modem and download the initialization string required to receive a call from the Server modem RBH Access Technologies Inc Integra32 Hardware Guide 51 1 Specification Sheets Server Host Site Modem Install modem in Windows 1 Use the modem setup TAPI screen in Windows Control Panel to install a modem for any available COM port on the Server 2 From the Modem Properties window you can add a modem remove a modem or edit modem properties You can access modem properties from Control Panel Click the Add button Phone And Modem Options 2 xl Dialing Rules Modems Advanced The following modems are installed Modem Sportster 56k Data Fax COM1 Add Remove Properties Apply Figurel Phone and modem Options window 3 You may choose to let the Install New Modem wizard auto detect your modem or select it yourself You will have to specify the COM port that you will use for that modem 4 Once the modem has been installed you may edit the settings to correspond with the remote site s settings 5 InFigure 2 right click on modem and select properties to open modem properties window RBH Access Technologies Inc Integra32 Hardware Guide 52 1 Specification Sheets E Computer Management File Action View Window Help e mm m J Computer Management Local TESTING 14 Syste
12. 485 Bias Low RS485 tuning Termination RS485 tuning Bias High RS485 tuning Integra32 Hardware Guide RBH Access Technologies Inc 12 Chapter 2 Intelligent Field Panel URC2000 Connection Details Power The URC 2000 requires 9 to 14 volts DC and draws about 200ma PC Interface The PC interface connects the URC 2000 to a PC through an RS485 2 wire connection Inputs There are two common terminals for each set of inputs one between inputs one and two another between three and four Seven different input types are supported including normally open normally closed one resistor and two resistor configurations Outputs Two of the four programmable outputs are dry contact relays UL rated 2A 50v dc These are designated as outputs one and three The other two outputs are solid state switches open collector to ground capable of sinking 100ma Readers Readers are connected to non programmable outputs BUZ amp LED as well as data inputs DO and D1 Both readers have their own connection terminals reader A is designated as P4 and reader B is designated as P5 RBH Access Technologies Inc Integra32 Hardware Guide 13 Chapter 2 Intelligent Field Panel URC2000 Wiring Diagram RS485 Connection Door Lock In Out Signal Ground 12 volts _ Request to Exit Door Contact _ Lock Power Lock Integra32 Hardware Guide RBH Access Technologies Inc 14 Eart
13. A V Hl Keypad Network Summit 3208GLD 87654321 RBH Access Technologies Inc Integra32 Hardware Guide 50 1 Specification Sheets Appendix B Dialup Modem Configuration Setting up a dialup network requires two 2 modems one connected to a serial port on the Server and one connected to the first IRC2000 board at the remote site Remote Site Modem 1 Set DIP Switches 1 through 5 to define the IRC2000 s address 2 RBH recommends a U S Robotics external Sportster modems and a baud rate of 9600 3 Make any DIPswitch settings on your modem as per your modem manual and the Integra32TM hardware manual Parameter Setting Auto Answer AA ON Data Terminal Ready DTR or TR ON Override Verbal Result Codes ON Suppress Result Codes OFF Echo Commands OFF Carrier Detect CD OFF Normal These settings on the recommended modem would mean that all modem DIPswitches 1 3 4 7 and 8 were down except switches 2 5 amp 6 which will be up Note PC side modem will not work with above DIP switches settings PC side modem has to be set to default settings 3 5 8 4 Check the telephone line for dial tone and connect the phone cord to the modem 5 Power up the modem and check the front panel lights to verify that the AA TR and CD settings are correct as per the above table 6 Pluginthe IRC2000 to Modem cable See the Hardware Manual for pin outs 7 Power up the IRC2000 The IRC200
14. Access Technologies Inc Integra32 Hardware Guide 15 Chapter 2 Intelligent Field Panel Computer Port Baud Rate Selection The controller s RS485 port baud rate is set with DIP switches 6 and 7 This setting determines the speed used to communicate with the controllers connected to the software through the same port must have the same baud rate The default PC baud rate is 38 400 Controller Baud Rate Selection OF 2880 F ON OoN 5600 PC Connections RS485 Connection The URC 2000 controller supports a two wire RS485 interface The RS485 interface allows the distance between the controller and the PC to be up to 4000 feet 1200 meters RS485 requires one twisted pair shielded cable Integra32 Hardware Guide RBH Access Technologies Inc 16 Chapter 2 Intelligent Field Panel Status LED s Communication Port The RS485 port has two LEDs to show the flow of data between the URC 2000 controller and PC The red LED LED flashes when the controller receives data The green TX LED LED2 flashes when the controller transmits data If the controller is connected directly to the PC the status LED s flash continuously Run LED The run LED LED3 flashes to indicate the controller is not communicating it is on solid when running normally and off if power is missing Fuses There are two 1 amp self resetting Polyfuses on the URC 2000 board F1 is connected to Re
15. High Security Mode eese 32 I Input Circuit 24 23 Intelligent Field Panel sees 2 Introducing Integra32 1 IRC2000 Baud Rate Selection sees 6 Connection Details sees 2 Connection Diagram 33 DIP Switch Settings 5 USES p EA 11 ione c ei aeons 12 Modem Selection eene 6 PC Connections 7 PC Modem Interface esee 2 RS485 9 Specification 36 Status LED S cseteris 11 Wiring ettet tetti 3 J Jumpers Elevator Control 22 2000 oe te e Ier 12 URG22000 vis iret EUR 17 K Keypad Reader Combination 32 Integra32 Hardware Guide 41 Index L Lock Output ote teme 28 30 M Magnetic Lock Connection Diagram 30 Modem Connection eseeeeeene 8 Modem Power Output eese 28 OUtpUts satse 28 PC Interface IRC 2000 2 i RU RT 2 PC 100 ene 21 URC 2000 2 aeree 13 PC100 Connection Details esee 21 Specification 38 Relay Output Operation 30 Request to 23 RS232 Connection entere 7 RS485 Connection IRC 2000
16. Integra32 Integrated Alarm Monitoring and Access Control HARDWARE MANUAL Copyright Notice Copyright 1995 2010 by RBH Access Technologies Inc rights reserved Worldwide Printed in Canada This publication has been provided pursuant to an agreement containing restrictions on its use No part of this book may be copied or distributed transmitted stored in a retrieval system or translated into any human or computer language in any form or by any means electronic mechanical magnetic manual or otherwise or disclosed to third parties without the express written consent of RBH Access Technologies Inc Mississauga Ontario Canada Trademark Integra32 is the trademark of RBH Access Technologies Inc Windows is a trademark of Microsoft Corporation other product names mentioned herein are the property of their respective owners Use of a term in this book should not be regarded as affecting the validity of any trademark or service mark Disclaimer This book is provided as is without warranty of any kind either express or implied including but not limited to performance merchantability or fitness for any particular purpose Neither RBH Access Technologies Inc nor its dealers or distributors shall be liable to any person or entity with respect to any liability loss or damage caused or alleged to have been caused directly or indirectly by this information Further RBH Access Technologies Inc reserves the rig
17. PC over a modem Contact the RBH tech support office for information on the optional TCP IP Ethernet connection Direct Connect Modem Selection DIP Switch 8 Interface Type Direct Connect To PC DIP switch 8 specifically turns on the password requirement and enables modem call back The panel will still answer a modem call with DIP switch 8 off You should initially set up the panel with DIP switch 8 off program the panel and download to it Then turn DIP switch 8 on to enable password checking Computer Modem Port Baud Rate Selection The controller s serial port baud rate is set with controller DIP switches 6 and 7 This setting determines the speed used to communicate with the modem or PC serial port If the controller is connected directly to the PC the controller baud rate must be the same as the baud rate set for the port on the PC The default PC baud rate is 38 400 Controller Baud Rate Selection F F F F ON 38 ON F F ON OoN 5600 Integra32 Hardware Guide RBH Access Technologies Inc 6 Chapter 2 Intelligent Field Panel PC Connections RS232 Connection The PC serial port used to connect to the IRC 2000 panels is assigned under the Communication Port Setup screen of Network properties window in the Integra32 software The baud rate is set by default to 9600 for direct connection to the PC using the standard RS232 interface The RS232 interface can be used to connect to a sing
18. Power The ELC 08 requires 9 to 14 volts DC connected to the Data Input and draws a maximum of 325ma Data Input Data Output The first ELC 08 is connected to the Elevator URC2000 Four wires are connected as per the diagram above The second third and fourth boards are each connected to the previous board Board four connected to board three board three connected to board two and board two connected to board one Connect Ov to Ov D to D D to D and 12v to 12v Fire Signal Apply 12 24 volts DC to satisfy this input When this voltage is removed all of the relays on the board will power down turn ON making all floors accessible If the Fire Signal feature is not required install a jumper on the Fire Signal Bypass Integra32 Hardware Guide RBH Access Technologies Inc 20 Chapter 2 Intelligent Field Panel PC100 Connection Details GNDB DCDGNDRX TX RBH 59 DIAG CANADA S12 DIAG2 www rbh access com _ O RX TX 12345678 CH3 OG RX TX Power The PC 100 requires 9 to 14 volts DC and draws about 150ma PC Interface The PC interface connects the PC 100 to a PC through an RS232 serial connection at 9600 baud only RBH Access Technologies Inc Integra32 Hardware Guide 21 Chapter 2 Intelligent Field Panel RS485 Interfaces Connect the PC 100 to IRC 2000 amp URC 2000 panels through an RS485 connection and connect the PC 100 to an Alarm Panel through an RS485 connection Stat
19. ader Power and F2 is connected to Main Power Jumpers 1 Bias Low RS485 tuning JP2 Termination RS485 tuning JP3 Bias High RS485 tuning RBH Access Technologies Inc Integra32 Hardware Guide 17 Chapter 2 Intelligent Field Panel Elevator Control Integra32 Elevator Control uses a modified URC2000 board with ELC firmware OV D D 12V ELC 08 OV D D 12V ee DATA INPUT DATA OUTPUT FIRE SIGNAL BYPASS ba Od Up to four ELC 08 relays boards may be connect strung together for a maximum of thirty two dry contact outputs per Elevator Control panel These contacts are programmed as state de energized so that the release of the fire signal or power will place the outputs in the ON state There are red LEDs one for each relay that turn on as each relay is energized therefore indicating an off state The green LED next to the data input connector flash when communications is lost Another green LED next to the Fire Signal connector indicates the presence of a Fire Signal or Fire Signal Bypass Integra32 Hardware Guide RBH Access Technologies Inc 18 Chapter 2 Intelligent Field Panel Connection Details ELC 08 Installation URC2000 aa Controller 0 uu First stage output board for outputs 1 8 e bten Second stage output board outputs 9 16 RBH Access Technologies Inc Integra32 Hardware Guide 19 Chapter 2 Intelligent Field Panel
20. ails s dee oie tese c RR ade ra e SRE 13 ss etsi t raise 15 DIP Switcli Settings edge Ree pepe e He I e Pe O Eee er dde teneo 15 IPOLCOnHectlOnmm 16 TEE 17 EID du EET 17 ELEVATOR CONTROL 18 Connection rS TE EER a oe ee 19 sansen mapu men 21 Connection Details dec 21 Stat s 22 22 CHAPTER 3 INPUT amp OUTPUT CONNECTIONS toss seta sess esten setas sesta ee 23 INPUTS inttr tie rt Ee ERR 23 Request to Exit 5 4 aede ier eie edet Ee eee e aee id dn ee ee ren ee dE ev ela e aa eins 23 DC Door Contact vaso RO RE RETE D TEE abe ta Ba ae 23 General PULPOSE sus su t t Eee tp en e e trip Eee etr ped 23 INPUT CIRCUIT TYPES Sissener EE Rte a REOR OE oV EE EXER e perd ee 24 OUTPUTS 28 Lock qiie needed pad eene de i ota epa vede iE 28 Handicap Output edge e gegen Ret e te Belo te Ede e dde tege 28 Alarm Shuhnt Output idi oer OR RH e ERE ORE FUIS DR E C SPURS herir Pe 28 Modem Power ond eit e RE t ep Red eR ere 28 General Purpose Outplt eh coed it deres err re ead 28 Switching Inductive Devices Locks 29 RELAY OUTPUT OPERATION 30 Lock O
21. erent input types are supported including normally open normally closed one resistor and two resistor configurations Four of the eight programmable outputs are dry contact relays UL rated 2A 30v dc These are designated as outputs one two five and six The other four outputs are solid state switches open collector to ground capable of sinking 100ma Readers are connected to non programmable outputs BUZ RED amp GRN as well as data inputs DO and D1 Both readers have their own connection terminals reader A on the left side of the board and reader B on the right Integra32 Hardware Guide RBH Access Technologies Inc 2 Chapter 1 Intelligent Field Panel IRC2000 Wiring Diagram Lock Power Lock Power Q GND RS485 Connection to additional units RBH P51224 24 RBH Access Technologies Inc Integra32 Hardware Guide Chapter 2 Intelligent Field Panel Earth The controller contains several layers of protection against induced high voltage transients from static discharge lightning and power line spikes In order for this protection to be fully effective a good connection to earth ground is essential Wire this connection to a metal cold water pipe or similar structure Do not connect directly to the AC earth Use 16 AWG or heavier cable and keep the length as short as possible less than 50 feet 15 meters For multiple panels always use only a single point ground reference for all panels Bring
22. eters Integra32 Hardware Guide RBH Access Technologies Inc 8 Chapter 2 Intelligent Field Panel TCP IP Connection For TCP IP connections wire to the TCP IP interface as you would to the PC with a direct RS 232 connection The TCP IP interface is programmed with an IP address and connected to the LAN contact the local system administrator for an IP address Additional controllers can be connected via the RS 485 connection terminals RS485 Connection The IRC 2000 controller supports a two wire RS485 interface Jumpers JP1 is to be set on the lower two pins for RS485 operation The RS485 interface allows the distance between the controller and the PC to be extended up to 4000 feet 1200 meters RS485 requires one twisted pair shielded cable Cable Specification single twisted three conductor shielded 18 to 22 AWG Maximum Cable Length 4000 feet 1200 meters RBH Access Technologies Inc Integra32 Hardware Guide 9 Chapter 2 Intelligent Field Panel Controller Networks Up to thirty two controllers can be connected to a single PC They can be connected to the same network or distributed across multiple networks After the first controller of the network is connected to the PC additional controllers can be connected to the network via the RS485 terminals Connect the TX A terminal of one controller to the TX A terminal next one and connect the RX B terminal to the RX B terminal All of the controllers on a networ
23. gra status Communication Channel LEDs Each communication channel has a green transmit LED and a red receive LED Normally flashing at a rate of once a second DIAG2 will flash twice as fast if the unit is offline with the Integra network RBH Access Technologies Inc Integra32 Hardware Guide 44 1 Specification Sheets DSC Alarm Panel Interface It is recommended that the user be familiar with the DSC alarm panel and has the ability to program PIN codes and parameters into the panel The PC100 interface has been designed to connect the Integra network to the DSC alarm panel through the keypad bus It will emulate a keypad when a link has been provided and report status to the Integra network when included in the list of keypads Keypad States The emulated keypads in this case are representations of partition states A partition can be armed disarmed or in alarm Panic Emergency and Fire alarms initiated by the alarm panel will be reflected on the first keypad Input States In addition to the keypads the PC100 will also emulate 256 inputs Each input address will be mapped directly from the DSC alarm panel interface When an input changes state on the alarm panel the PC100 will report the change of state as if it happened on its own panel Status Display Partition 1 Alarm Status i le N Mode Disarmed Zones Name Status gH 1 Front Gate Abnormal 2 Front Door Normal d Side Door Normal 4 Garage
24. gramming it Integra32 Hardware Guide RBH Access Technologies Inc 22 Chapter 3 Input amp Output Connections Chapter 3 Input amp Output Connections Inputs The IRC 2000 has eight fully supervised inputs two sets of four each with two common terminals and the URC 2000 has four fully supervised inputs two sets of two each with a common terminal All inputs are individually programmable from the PC The panels employ digital filtering to eliminate the effect of interference on the input loops and to verify all loop changes before reporting to the controller Each input can report up to four states Open Short Abnormal and Normal For example if the circuit type is programmed as 2 resistor normally closed 1k represents a normal state and 2k represents an abnormal state Less than twenty ohms is a short and very high resistance is an open RTE Request to Exit Inputs programmed as RTE will be connected to push buttons mounted on the door or to motion detectors mounted near the door Activating the RTE input will cause a grant access to be executed on the appropriate door The RTE can be disabled by a schedule Multiple inputs can be programmed as RTEs for the same door DC Door Contact Inputs programmed as door contacts monitor the state of the door Forced entry door held open alarm and door held open warning require monitoring of the door state General Purpose General Purpose Inputs are inputs that are no
25. h Chapter 2 Intelligent Field Panel The controller contains several layers of protection against induced high voltage transients from static discharge lightning and power line spikes In order for this protection to be fully effective a good connection to earth ground is essential Wire this connection to a metal cold water pipe or similar structure Do not connect directly to the AC earth Use 16 AWG or heavier cable and keep the length as short as possible less than 50 feet 15 meters For multiple panels always use only a single point ground reference for all panels Bring the shields of all reader and communication cables back to one location Do not connect them to the panel or the panel s housing DIP Switch Settings The URC 2000 s DIP switches control a number of operating parameters including the device address and serial port baud rate The controller must be powered down to accept any changes in the DIP switch settings Use DIP switches one through five to set the controller address Switches six and seven set the communication baud rate and switch eight is used to set the connection type modem or direct DIP Switch DIP Switch Controller Address Controller Baud Rate Controller Addressing Use DIP switches 1 2 3 4 and 5 to select the controller address The address is binary coded and the switch settings for all sixteen possible addresses are given below Controller Addressing Off Off Off Off RBH
26. his interference can be suppressed by placing a diode 1N4004 or similar across the lock or other inductive device being switched Connect the diode cathode end with band to the positive terminal and the other end to the negative terminal The diode must be placed at the device being switched and not at the controller RBH Access Technologies Inc Integra32 Hardware Guide 29 Chapter 3 Input amp Output Connections Relay Output Operation Lock Output Any output can be used to control a magnetic lock or door strike Multiple outputs can be set to the same function outputs one and two can both be Lock outputs for reader A Magnetic Lock Connection Diagram For magnetic locks the relay should be configured from the PC as On State de energized for fail safe operation If power fails AC and battery the power to the magnetic lock is removed and the door is opened Integra32 Hardware Guide RBH Access Technologies Inc 30 Chapter 3 Input amp Output Connections Door Strike Connection Diagram Diode 1N4004 Handicap Output Connection Diagram Door Actuator Input If this output is used with an inductive load use a back EMF diode as described on page 29 to prevent damage to other equipment RBH Access Technologies Inc Integra32 Hardware Guide 31 Chapter 3 Input amp Output Connections Access Point Operating Modes High Security In high security mode only cardholders with super
27. ht to revise this publication and to make changes to the content hereof from time to time without the obligation of RBH Access Technologies Inc to notify any person or organization of such revision or changes FCC This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation RBH ACCESS TECHNOLOGIES INC 2 Automatic Road Suite 108 Brampton Ontario CANADA L6S 6K8 Integra32 Revision 4 2 Printing Date 25 February 2010 Integra32 Hardware Guide RBH Access Technologies Inc Table of Contents Table of Contents CHAPTER 1 INTRODUCING INTEGRA 2 iis ies aii Du d Id ER 1 CHAPTER 2 INTELLIGENT FIELD PANEL ecce ee ee eere ee enero etta sette stan Pese setas eee seen see 2 IRC2000 uses 2 Connections Details eir ree etos vea eo ots Ye e Po ee 2 EF eerta A e ES E IERI dritte oa e Oe ts dee TEER EAE c 4 DIP Switch Settings ai php d eee eer eda eo nep e ied tesa 5 PC Connections s ee ede lot c 7 Controller Networks arier sakte en 10 Status LED nae E eain eee IR 11 12 200027 reset 13 Connection Det
28. instead of the original IRC 2000 This panel also uses fully distributed intelligence for off line operations In addition to supporting two card readers each URC 2000 panel has four fully supervised alarm inputs and four outputs as well as a 3 000 card capacity Communication is handle through an RS485 port The PC is used for data entry setting up the database and monitoring activity on the system Once the database is downloaded to the controllers the PC is not required for system operation Should the PC be powered down the controller will perform all access and other control functions but of course not Global functions including logging history events When the connection is restored the log will then be reported to the PC Up to thirty two panels can be connected together for a maximum capacity of sixty four doors Connect the PC to the first control directly via RS232 or by an IP address using an existing Ethernet Additional controls can be connected to the first control with RS485 maximum total wiring distance is four thousand feet to a maximum of sixteen panels per connection or network Interfacing with intrusion alarm panels has been made possible Connect to Bosch or Summit panels through the PC 100 board Elevator control is accomplished with a modified URC2000 panel and ELC 08 relay boards Four relay boards can control up to thirty two floors for two readers Other features include the capacity for forty holidays
29. interface the Electronics Line Summit alarm panel to the IRC2000 access control system 1 RS232 RS485 TCP IP Host for communication with the PC software running Integra32TM 2 RS485 Panel for connection to the LSCP bus on the Summit alarm panel 3 RS485 IRC for connection to the Access control system channels are programmed for a baud rate of 9600 8 bits no parity and all Integra32 panels need to be programmed for 9600 baud activity is synchronized to the Summit LSCP bus If the bus is disconnected all activity on the PC100 will halt The PC100 acts like a zone expander to the Summit panel allowing up to 32 zones Each zone is mapped to an element in the IRC network The state of each element in the IRC network will cause a zone to appear open or closed The PC100 acts like an IRC panel at address 32 to the host The host can poll the PC100 to see if it is online request status write to memory and update flash memory P IRC2000 panels connected along with the PC100 must be running firmware version 76 or higher for the PC100 and the IRC2000 panels to function together correctly Programming an Arm Disarm key switch When an Access Granted message is used source for an input the status of the alarm panel is checked before execution is allowed If the function is to disarm the panel and the panel is already disarmed no action will take place Conversely if the function is to arm the panel and the panel
30. k are connected in parallel Controller Network Connection Diagram RS232 to RS485 Converter Network 1 R5 232 5 485 Network 2 Network 3 RS232 to Ethernet convetrer Integra32 Hardware Guide RBH Access Technologies Inc 10 Chapter 2 Intelligent Field Panel Status LED s Computer Modem Port The computer modem port has two LEDs to show the flow of data between the IRC 2000 controller and PC or modem The red RX LED LED3 flashes when the controller receives data The green TX LED LED4 flashes when the controller transmits data If the controller is connected directly to the PC the status LED s flash continuously Run LED The run LED LED2 flashes to indicate the controller is not communicating it is on solid when running normally and off if power is missing Diagnostic LED This LED will be on if either reader A or reader B buzzer output is on Fuses There are two 1 amp self resetting Polyfuses on the IRC 2000 board 1 is connected to Reader Power and F2 is connected to Main Power RBH Access Technologies Inc Integra32 Hardware Guide 11 Chapter 2 Intelligent Field Panel Jumpers JP1 JP2 JP3 JP4 The upper position is for RS232 and the lower position is for RS485 In a multi panel network with the first panel connected to the PC via RS 232 and all other panel connected to the first panel via RS 485 set JP1 of panel 1 to RS 232 and all other JP1s to RS
31. le controller or to the first controller of a network The distance between the PC and controller can not be greater than 150 feet 45 meters or 30 feet 9 meters if the baud rate is increased to 38 400 For distances greater than 150 feet 45 meters an RS485 interface must be used RS485 is built into the IRC 2000 controller but is not part of the standard PC The PC must be fitted with either an RS485 serial card or an external RS232 to RS485 serial port converter Additional controllers can be connected via the RS485 terminals Controller to PC Connection RS232 PC to IRC 2000 RS232 Interface Wiring Jumper JP is in the upper position for RS232 Cable Specification 3 or 4 conductor shielded 18 to 22 AWG Maximum Cable Length 9600 baud 150 feet 45 meters 56000 baud 50 feet 15 meters RBH Access Technologies Inc Integra32 Hardware Guide 7 Chapter 2 Intelligent Field Panel Modem Connection Jumper JP is in the upper position for RS232 The IRC 2000 can be connected to the PC via a modem The modem connection is similar to the RS 232 connect with the inclusion of the DCD terminal If multiple controllers are used then the RS 485 connecter will be needed to connect the additional controllers to the modem controller Connected to additional panels Cable Specification 4 conductor shielded 18 to 22 AWG Maximum Cable Length 9600 baud 150 feet 45 meters 56000 baud 50 feet 15 m
32. m Tools g Event Viewer 3 Computer sp Disk drives 2 Display adapters 5 DVD CD ROM drives Human Interface Devices 3 IDE controllers 9 Keyboards Removable Storage 9 Mice and other pointing devices Disk Defragmenter IL Modems Disk Management Standard 33600 bps Modem EH d Services and Applications 3 Monitors BB Network adapters Ports COM amp LPT s Processors 9 Sound video and game controllers System devices Universal Serial Bus controllers Shared Folders P Local Users and Groups Performance Logs and Alerts Device Manager 55 Storage Fe REI E TI T E FE E E Figure 2 Opening modem properties from device Manager RBH Access Technologies Inc Integra32 Hardware Guide 53 Appendix 1 Specification Sheets 6 Use the Properties button to set the desired modem parameters e g Max Speed of 9600 for a 56 6k modem Use parameters appropriate for the remote site that you are connecting to Standard 56000 bps Modem Properties General Modem Diagnostics Advanced Driver Details Port COM1 Speaker volume Off Maximum Port Speed 66 Dial Control Wait for dial tone before dialing Figure 3 Modem properties RBH Access Technologies Inc Integra32 Hardwa
33. more information on the Exit Reader Interface check TB51 Exit Reader Interface pdf Integra32 Hardware Guide RBH Access Technologies Inc 34 Specifications Specifications RBH Access Technologies Inc Integra32 Hardware Guide 35 Specifications IRC 2000 Controller Power Requirements Specification 9 14V DC Current Consumption 250ma Flash ROM Download firmware upgrades from the PC to IRC 2000 System Capacities IRC 2000 s per System Readers per IRC 2000 2 Cardholder normal extended Event Log per IRC 2000 Maximum of 32 Maximum 5 000 Maximum 8 000 Maximum 1 400 Network Connection Type RS 232 or RS 485 Serial Port Speed 9600 28800 38400 or 56000 Real Time Clock Dallas DS1994 with battery back up Housing dimensions 12in x W 14in x D Operating temperature 0 to 70 C 35 150 F Operating Humidity 20 to 80 RH non condensing PC Connection Can be connected via RS232 RS485 or by Modem Integra32 Hardware Guide 36 RBH Access Technologies Inc Specifications URC 2000 Specification Controller Power Requirements 9 14V DC Current Consumption 200ma Flash ROM Download firmware upgrades from the PC to URC 2000 System Capacities URC 2000 s per System Maximum of 32 Readers per URC 2000 2 Cardholder Maximum 3 000 Event Log per URC 2000 Maximum 1 400 Network Connectio
34. n Type RS 485 Serial Port Speed 9600 28800 38400 or 56000 Real Time Clock Dallas DS1994 with battery back up Board dimensions 3in x W Operating temperature 0 to 70 35 150 F Operating Humidity 20 to 8096 RH non condensing PC Connection Can be connected via RS485 RBH Access Technologies Inc Integra32 Hardware Guide 37 Specifications PC 100 Specification Controller Power Requirements 9 14V DC Current Consumption 150ma Flash ROM Download firmware upgrades from the PC to PC 100 System Capacities PC 100 s per System Maximum of 1 Network Connection Type RS 232 and RS 485 Serial Port Speed 9600 28800 38400 or 56000 Real Time Clock Dallas DS1994 with battery back up Board dimensions 4 Ain W 4 in Operating temperature 0 to 70 C 35 150 F Operating Humidity 20 to 80 RH non condensing PC Connection Can be connected RS232 RS485 or by Modem Integra32 Hardware Guide RBH Access Technologies Inc 38 Specifications ELC 08 Specification Controller Power Requirements 9 14V DC Current Consumption 325ma max System Capacities ELC 08 s per URC2000 Maximum of 4 Network Connection Type RS 485 Relay Outputs 1A Q 30vdc Board dimensions 3in x W 6 in Operating temperature 0 to 70 C 35 150 F Operating Humidity 20 to 80 RH non conde
35. nd four solid state outputs Outputs 1 2 5 and 6 are dry contact relays UL rated 2A 30v dc Outputs 3 4 7 and 8 use electronic drivers and can switch up to 100ma The URC 2000 has four outputs two relay outputs and two solid state outputs Outputs 1 and 3 are dry contact relays UL rated 2A 9 30v dc Outputs 2 and 4 use electronic drivers and can switch up to 100ma outputs are programmable from the PC as On State energized or On State de energized State de energized outputs are used for fail safe operation where it is essential that the output return to a safe state when the system fails due to power loss communications failure or fire Electronic outputs are switched negative which means that they switch the power negative to the terminal When the output is off the output terminal is electronically disconnected Outputs can be programmed for lock or handicap operation as described below or they can be used as general purpose outputs Lock Output The lock output is used to activate or deactivate the locking device on the door It can apply power to door strikes or remove power from magnetic locks Handicap Output This output is used to drive door operators It turns on in less than one second after the Lock Output is turned on and stays on until the Lock Output is turned off Only designated cardholders will activate this output Alarm Shunt Output This output is activated at the same
36. nsing RBH Access Technologies Inc Integra32 Hardware Guide 39 Specifications Cable Specification PC to Controller RS232 3 or 4 conductor shielded 18 to 22 AWG Maximum Cable Length 9600 baud 150 feet 50 meters 56000 baud 50 feet 15 meters 2 Wire RS485 Single twisted pair shielded 18 to 22 AWG Maximum Cable Length 4000 feet 1200 meters IRC 2000 URC 2000 to Reader 20 to 22 AWG 6 or 8 conductor stranded shielded not twisted Maximum Cable Length 22 AWG Cable 250 feet 75 meters 20 AWG Cable 500 feet 150 meters PC 100 RS232 to PC 3 or 4 conductor shielded 18 to 22 AWG Maximum Cable Length 9600 baud 150 feet 50 meters 56000 baud 50 feet 15 meters 2 Wire RS485 to panels Single twisted pair shielded 18 to 22 AWG Maximum Cable Length 4000 feet 1200 meters Input Output Port Circuit Loop 2 conductor 20 to 22 AWG Maximum Cable Length 1000 feet 300 meters Integra32 Hardware Guide RBH Access Technologies Inc 40 Index A Access eee 32 Access Granted eie pe e eU 32 Access Panel Interface sees 21 Access Point Operating 32 Alarm Panel Interface 21 Alarm Shunt Output eee 28 B Baud Rate 16 Cable Specification 40 Computer Modem Pott sees 11 Connection Details
37. re Guide 54 1 Specification Sheets 6 Set Advanced Connection Settings as follows Include Extra Initialization Commands of amp 6 to further force a baud rate of 9600 Standard 56000 bps Modem Properties General Modem Diagnostics Advanced Driver Details Extra Settings Extra initialization commands amp Change Default Preferences Figure 4 Modem Properties RBH Access Technologies Inc Integra32 Hardware Guide 55 Appendix 1 Specification Sheets Click on Query Modem button Figure 5 and you will see success message Figure 6 Otherwise you will see communication fails message Figure 7 Standard 56000 bps Modem Properties i General Modem Diagnostics Advanced Driver Details Modem Information Field Value Hardware ID motol gen Command Response Query Modem Logging Figure 5 Modem Diagnostics properties RBH Access Technologies Inc Integra32 Hardware Guide 56 1 Specification Sheets Standard 56000 bps Modem Properties General Modem Diagnostics Advanced Driver Details Modem Information Field Value Hardware ID motol gen Command Response ATQOVIEO Success AT GMM COMMAND NOT SUPPORTED AT FCLASS 0 1 2 0 ATHCLS COMMAND NOT SUPPORTED lt gt Logging
38. ress is included in the list of keypads programmed in the Integra network 2 The keypad emulation box has been checked 3 The keypad address has been programmed into the alarm panel In order for the alarm panel to poll the emulated keypad the keypad assignment for the alarm panel should be programmed Keypad addresses 1 10 connect to the keypad bus and addresses 11 15 is connected to the option bus The PC100 can monitor all keypads on the bus that are listed under panel properties Keypads A Link to an Event will use an emulated keypad to enter a password followed by a command If the password is not programmed into the alarm panel no operation will take place Whenever a command is executed the green DIAG2 LED will turn on The green DIAG2 LED will turn off when the alarm panel finishes its poll to the keypad Do not overload the power supply by connecting the IRC2000 s along with their weigand readers to the Bosch 12 supply RBH Access Technologies Inc Integra32 Hardware Guide 46 1 Specification Sheets Power 9 14vdc IRC2000 Network Computer Connection oo Bosch Alarm Panel Option or Keypad Bus Use Option Bus for addresses 11 15 Use Keypad Bus for addresses 1 10 RBH Access Technologies Inc Integra32 Hardware Guide 47 1 Specification Sheets Summit Alarm Panel Interface General description The PC100 when made for the Summit application will
39. t tied directly to an access point The user defines what happens when they change state They can trigger links cause alarms and or report their change of state RBH Access Technologies Inc Integra32 Hardware Guide 23 Chapter 3 Input amp Output Connections Input Circuit Types The IRC 2000 supports seven different input circuit types ranging from no resistor for low security applications to two resistors normally closed circuits where the highest security is required Normally Open No Resistor Integra32 Hardware Guide RBH Access Technologies Inc 24 Chapter 3 Input amp Output Connections Normally Closed Two Resistor 1K This circuit provides a high degree of supervision and detects both short and open circuit fault conditions Use this circuit in high security applications RBH Access Technologies Inc Integra32 Hardware Guide 25 Chapter 3 Input amp Output Connections Normally Open One Resistor Loop Resistance Open Circuit Integra32 Hardware Guide RBH Access Technologies Inc 26 Chapter 3 Input amp Output Connections Normally Open And Normally Closed One Resistor 1k Restore This circuit type is used where normally open and normally closed contacts are used in the same loop RBH Access Technologies Inc Integra32 Hardware Guide 27 Chapter 3 Input amp Output Connections Outputs The IRC 2000 has eight outputs four relay outputs a
40. te 5 Enter a password Connect the first time with Dip switch 8 off 6 Click OK to complete the configuration In House Hardware Setup RBH Access Technologies Inc Integra32 Hardware Guide 58 1 Specification Sheets PC CONNECTOR Op ed Sportster 33 6 Faxmodem yore pyar pi PC Mocdem 33 6 Fax Modem al Products ation Phoneline Simulator i t Ramesses Sportster 33 6 Faxmodem as aa as Panel Modem P Note Panel modem side 25 pin DB connector wiring diagram is incorrect Please refer to diagram below RBH Access Technologies Inc Integra32 Hardware Guide 59 1 Specification Sheets Modem Connection The IRC 2000 can be connected to the PC via a modem The modem connection 1s similar to the RS 232 connect except that the TX amp RX connections are straight through instead of crossed with the inclusion of the DCD terminal If multiple controllers are used then the RS 485 connecter will be needed to connect the additional controllers to the modem controller Jumper JP is in the upper position for RS232 Cable Specification 4 conductor shielded 18 to 22 AWG Maximum Cable Length 9600 baud 150 feet 45 meters 56000 baud 50 feet 15 meters RBH Access Technologies Inc Integra32 Hardware Guide 60
41. us LED s Health The green health LED indicates synchronization with the LSCP bus and the red health LED indicates LSCP problems For normal operation the green led will be flashing quickly and brightly and the red led will be mostly off PC Interface The PC Interface port has two LEDs to show the flow of data between the PC 100 and the PC The red RX LED LED flashes when the controller receives data The green TX LED LED10 flashes when the controller transmits data Access Panel Interface The Access Panel Interface is an RS485 port that has two LEDs to show the flow of data between the PC 100 and IRC2000 and or URC2000 panels The red RX LED LED5 flashes when the controller receives data The green TX LED LED6 flashes when the controller transmits data Alarm Panel Interface The Alarm Panel Interface is an RS485 port that has two LEDs to show the flow of data between the PC 100 and a Bosch or a Summit panel The red RX LED LED flashes when the controller receives data The green TX LED LEDS flashes when the controller transmits data Jumpers JP1 Do not use for developmental purposes only 2 amp Both jumpers are left in the upper position for normal operation This will connect the PC Interface port to the micro controller Move the jumper to the lower position only if a LAN interface module is attached to the PC100 This will connect the PC Interface port to the LAN interface module for the purpose of pro
42. utput ede p rede eR ie rese ta Re deti iva dts 30 ACCESS POINT OPERATING MODES 32 ettet e ned ette n fe bases ettet 32 UNIO CRED ai t ecu UNI UM 32 Door Held Open Wamirng 2 tese petere S Eee OUR ERE e a re cuna pe 32 Door Held 32 RBH Access Technologies Inc Integra32 Hardware Guide Table of Contents Keypad Reader Combination nisiwe et tene E REN e UR SERE URS e 32 RE 32 Access c 32 EXIT READER INTERFACE CONNECTION 5 33 IRG 2000 GISELE a kunde 33 2000 e 34 IRC 2000 SPECIFICATION M 36 URC 2000 SPECIFICATION 37 1005 Pe boo eee owe eoe dvo fe ovo dus eese do Veg eU RS 38 ELC 08 SPECIFICATION P 39 CABLE SPECIFICATION 40 E EEEN T 41 EICENSE WARRANTY 055 cuc 43 APPENDIX A PC 100 INTERFACE APPLICATION ssccccssssssssssssscsssssccessssccsessscccsssscccesssccscssssccssseccccssses 44 WIRING e ient neue euentu 44 DSC ALARM PANEL INTERFACE eere nenne tenete
43. visor privilege are allowed access Unlocked The green LED turns on to indicate the door is unlocked Door Held Open Warning The Buzzer beeps slowly Door Held Open Alarm The Buzzer beeps continuously Keypad Reader Combination The Buzzer emits a series of short beeps every second after a card is presented until a PIN is entered Access Granted The Buzzer emits one long beep and the green LED turns on for the duration of the unlock time Access Denied The Buzzer emits two short beeps and the red led flashes twice Integra32 Hardware Guide RBH Access Technologies Inc 32 Chapter 3 Input amp Output Connections Exit Reader Interface Connection Diagrams The Exit Reader Interface board enhances the IRC2000 and URC200 panels by allowing the connection of two readers to a single reader port A single reader port can now have an In and an Out reader IRC 2000 Connection Connect the Out reader to the seven pin terminal and the In reader to the eight pin terminal Also connect the eight pin terminal to the panel s reader port For the IRC2000 connect the SIG terminal of the interface to the TAM terminal on the reader port If you are connecting to a URC2000 connect the SIG terminal to appropriate A or B terminal as indicated by the diagram below RBH Access Technologies Inc Integra32 Hardware Guide 33 Chapter 3 Input amp Output Connections URC 2000 Connection For