Home
Business/ Home GSM Alarm System
Contents
1. to inform the user When the external power recovered the system will send SMS Power changer on Switch turn left to start the host otherwise close Antenna GSM antenna you should connect the antenna before power supply 7 10 pin ports GND SIREN RELAY1 RELAY2 SPEAKER Oa Is Ox I4 13 l2 l4 GND is educed end of ground SIREN is to connect one end of siren the other end connects to GND RELAY 1 2 relay output It is normally opened and will keep closed for three minutes when alarming this function can be set off When alarming it can link the power video etc SPEAKER is to connect the speaker the other end of speaker connects to GND h l2 Is l4 Is are wired inputs short circuit or disconnect to GND will trigger alarm lll Installation a Use a normal SIM card delete all telephone numbers and messages in the SIM card insert SIM card b Then connect GSM antenna c Plug in DC power supply and power on the unit The LED will change LED status explanation RECORD SIGNAL STATUS POWER LED Status System working status Hasn t turned on the switch hasn t Off connected the power no power in POWER built in battery power supply is normal SIM card or GSM network is abnormal SIGNAL Green flash SIM card and GSM signal are normal RECORD Remote controlled by SMS commands Red flash quickly Orange Check SIM card and search GSM flash
2. even melt some plastic parts Do not place the system in excessively cold locations Otherwise condensation many occur and damage the circuit board of the alarm system It is recommended that you check and test the alarm system periodically Check the main unit every three months 1 Whether it can arm disarm normally 2 Whether it can dial the number for alarm normally 3 Whether it can receive wireless detectors signal normally 4 Whether the back up battery can work normally Check the wireless detectors once a month 1 Trigger wireless detectors to see if system can alarm normally 2 Check all detectors batteries to see if it s in low voltage 3 Check whether wireless detectors can send signal to the main unit normally Check the SIM card 1 Check the use of SIM card such as network signal balance ect 2 Make sure the PIN code verification of the SIM card is closed 3 Please keep the password and SIM card number safe in case that other people remote control the system illegally Since the alarm system is continuously in operation or standby mode the supply adaptor of the control panel shall be connected to a safe and reliable socket 18 lt Do not place the system near your bedroom or office table because the siren will make high loudness sound in the case of alarm which may adversely affect your rest or work lt If the alarm system will not be used for a long time please disconnect t
3. number 13988821003 123456 1 8 13988821004 Call the 4th phone number 13988821004 123456 1 9 13988821005 Call the 5th phone number 13988821005 3 Defense zones setting can be set only by SMS Users can set the status of the defense zones according to their requirements a Wireless zones setting zone serial number 50 65 total 16 zones zone 00 15 SMS commands password zone serial number zone status Message content Zone status 0 disarm 1 arm 2 24 hour arm system default arm E g 123456 50 1 hall means set wireless zone 1 arm 50 indicates wireless zone1 the name of the zone hall can be set according to your actual situation b Wired zones setting zone serial number 66 70 total 5 zones zone 16 20 SMS commands password zone serial number Zone status Message content Trigger type Zone status 0 disarm 1 arm 2 24 hour arm system default arm Trigger type 1 open circuit trigger to alarm 0 short circuit trigger to alarm system default 0 shorted alarm E g 123456 66 1 hall means set wired zone 1 arm and open circuit alarm NOTE The host has 16 solidified SMS of the wireless detectors wireless zone 0 15 the first SMS corresponds the first zone of wireless detectors other detectors are the same The host also has 5 solidified messages of the wired detectors wired zone 1 5 the first message corresponds the first zone of wired detectors other detectors are the same
4. slowly network SIM card and GSM signal are normal in disarm status Out Arm flash slowly Home Arm flash quickly STATUS Orange flash slowly Out Arm with delay time 10 s later green on Orange flash quickly Home Arm with delay time 10 s later green on or phone lt gt 2 Door sensors are used for detecting the status of open and close of windows and doors It will detect it and send Host Try to install the main panel in the center of defense zone and pull out the antenna to get longer wireless receiving distance Installation position should be far away from huge metal objects and wireless interference Install the main panel in a hidden place Door sensor the signal to main panel less than 10mm Tear apart the lt gt lt gt 3 double side adhesive tape on the magnet and the transmitter Then adhere them to the appropriate position Magnet should be near to the side of transmitter with indicator The two should align with each other and the distance should not exceed 10mm Please plug out the antenna for better signal If the low power indicator is on please change the battery Wireless PIR detector PIR detectors are used to detect the movement within a certain range lt gt Fix the adjustment bracket on the wall with the provided screws and attach the detector to the bracket It is recommended to mount it at a height of 2 2 2m above the floor lt Eff
5. 0 C 40 C Humidity lt 90 rh Wireless PIR Detector Power Supply DC9V built in 9V battery Static Current lt 100uUA Transmission Current lt 20mA Transmission Frequency 315 433MHZ 0 5MHZ 16 Transmission Distance No obstacle 80m Detective Speed 0 3 3m s Detective Distance 5 12m Detective Range Horizontal 110 Vertical 60 Working Condition Temperature 10 C 40 C Humidity lt 90 rh Remote Controller Power Supply DC 12V built in 12V battery Static Current 0 Transmission Current 15mA Transmission Frequency 315 433 0 5 MHz Transmission Distance No obstacle 80m Working Condition Temperature 10 C 40 C Relative Humiditys90 VII Care and Maintenance The alarm system has excellent design and used advanced technologies It shall be used with care The following suggestions are required to maintain your obligations under the warranty terms and for prolonging the service life of the system lt Place the control panel and all parts and accessories out of children s reach lt Keep the alarm system dry Rain humidity and various fluids or moisture all will corrupt the electronic circuit lt Do not use or place the alarm system in dirty locations otherwise the electronic elements will be damaged 17 lt gt lt gt Do no place the system in excessively hot locations High temperature will shorten the service life of electronic equipment damage batteries deform or
6. Business Home GSM Alarm System All Fer Your Security BUSINESS HOME GSM ALARM SYSTEM User Manual Profile For a better understanding of this product please read this user manual thoroughly before using it Thank you for purchasing this alarm system For proper use and your safety please read these instructions thoroughly and carefully before you put the system in use Keep this manual carefully for your reference in the future Precautions Please read and follow the brief instructions below otherwise physical danger or system damage may be incurred This manual contains more detailed information about safety issues concerning the system in other parts hereof Proper use Waterproofness Qualified maintenance service Read this manual The alarm system is Only those qualified carefully before you put not waterproof maintenance professionals the system in use Please keep it dry may repair the alarm system Operate in accordance with the instructions herein Backup Original parts and 40 Addition of batteries other equipment Be sure to back up all Only original parts and Before adding other important information batteries approved by equipment please read the stored in the system manufacturer may be used user manual for detailed otherwise the warranty term safety instructions Be sure may be breached and danger not to connect incompatible may occur products to the system WN Switch on safety Interfer
7. Users can send SMS and change its contents 4 Function settings Taking original password 123456 as examples The following functions can be set by SMS commands or phone SMS Content Function Description 4 1 123456 4 1 Open intercom function D O 123456 5 0 Relay disconnected D 1 123456 5 0 Relay connected When you do the above settings by phone call press password 12345 if you hear a long di it means the operation is successful if there s di twice it means the operation is wrong you should re input Press to clear if the input is wrong The following functions can be set only by SMS commands Function Command SMS Function Description fang e en Set the time 31 123456 31 18 00 auto arm of timing Arm time arm disarm disarm time 123456 Close auto arm disarm 31H function 32 0 123456 No siren sound when default on 32 1 123456 With siren sound when ee lem amg Relay 33 0 123456 Link the relay for 3 linkage 33 0 minutes when alarming default link 33 1 123456 Don t link the relay AE ee re eo 37 delay 123456 00 99 seconds default of delay arm 38 delay 123456 00 99 seconds default disarm alarm time 38 00 99 00 no delay when alarming Language 39 0 123456 English version Chinese 39 1 123456 Chinese version en lame O Addition set the system time Under normal working status send SMS password 31 Th
8. ect of the PIR detection is best when the detection direction is in 90 angle with the walking direction of the intruder Choose the most suitable installation place and angle according to actual situation and taking the following installation diagram as reference to ensure the window 10 30 detection effect is best lt Please do not fix it under direct sunlight or other strong lights and also keep it away from places with frequent strong air stream lt Ifthe low power indicator is on please change the battery IV System settings 1 Change the password of the system can be set only by SMS Format original password 30 new password new password is 0 6 digits For example change original password 123456 to 888000 send SMS 123456 30 888000 2 Set alarm phone numbers and SMS numbers can be set only by SMS The following operations take original password 123456 as example 123456 1 0 13988821001 Send SMS to the 1st phone number eee sameeren sama 123456 11 13988821002 Send SMS to the 2nd phone number Serie samaseer ang 123456 1 2 1 3988821 003 Send SMS to the 3rd phone number Sees somes mensan 123456 1 3 13988821004 Send SMS to the 4th phone number 123456 1 4 1 3988821 005 Send SMS to the 5th phone number 13988821005 when alarming 123456 1 5 13988821001 Call the 1st phone number 13988821001 123456 16 13988821002 Call the 2nd phone number 13988821002 123456 1 7 13988821003 Call the 3rd phone
9. ence Switch off in restricted areas Do not switch the Device All wireless devices may be Follow any restrictions on when wireless phone susceptible to interference Switch the device off in use is prohibited or when which could affect aircraft near medical it may cause interference performance equipment fuel chemicals or danger or blasting areas Catalog Functions gt Identify the Host Installation Bo aan a Camis E Door Sensor __ Wireless PIR detector System Settings Change Password Alarm Number Setting Defense Zone Setting Function Settings Audio Message Recording sX_si eee eee Add or Delete Detectors 2 0220222 e es Add New Detectors Delete Detectors Operation Instruction Remote Controller Components List Techniqucal Parameters 0 0000 e Care and Maintenance lt e2ttiscditecesriipemiiatetrree tigen CoN O O DTD THT MT w pp _ e N O gt oO N N oO 10 Ti 12 13 14 15 Functions GSM 900 1800 1900 bands can be used all over the world 5 wired and 16 wireless defense zones each can arm disarm and 24 hour arm independently SMS of each zone 5 wired zones 16 wireless zones can be edited independently Users can record 10 seconds alarm audio message with the scene location information Arm amp alarm delay function the delay time is adjustab
10. he system from the power supply lt Please do not disassemble repair and alter the products without permission or it may cause accidents and faults lt Do not drop this product on the ground or on hard objects as it may lead to massive impact to cause faults and damages lt Without approval and consent of relevant authorities please do not set 110 119 or the alarm phone number of police station for this main unit Please read the suggestions above carefully and follow the instructions herein If any of the equipment does not work properly please send it to the dealer or authorized service point for repair We will try our best to solve the problem for you as soon as possible 19 FAQ 1 Cannot alarm by phone Remote controlling distance is too short and the light indicator is not on bright enough Light indicator of door sensor and PIR is always on Dial alarm number slowly The main panel cannot receive signals from the accessory Hasn t armed Less than 30 seconds after arming Set wrong phone number The two parts of door window sensor is installed too far from each other Haven t activated PIR Hasn t checked code The battery of remote controller is rusty Low battery Low power battery The main panel has stored other numbers 1 Low power battery in the accessory 2 There is block between the control panel and the wireless accessory or the distance between them is too fa
11. le 00 99 seconds Timely arm disarm convenient for users and alarm center to control the system Can set 5 phone numbers which used to receive alarm phone and alarm SMS Set Out Arm Home Arm Disarm or Panic alarm with remote controllers Can control the system by calling in or SMS such as arm disarm listening in output and so on Listen in function can hear the sound of people move dig and other actions at the scene Two way intercom function can communicate with people at the scene SMS alert for power failure or recovery Password operation to make sure the security of system Siren port for shift between silence and sound Optional built in battery AC DC shift automatically recharge Identify the ports of the host RESET ON OFF ao RELAY1 RELAY2 INPUT SIM card slot at the back of the main panel there is a cover of the SIM card open the cover and insert SIM card then close the cover 2 Record press it for 2 seconds to enter recording status 3 Rset press RESET on the back of the host and then plug in power 5 6 The signal light flashes once or the siren sounds a di means the main panel has been reset The system restores to factory settings and all detectors are deleted default password is 123456 Power slot connect 12V 1 2A DC inner core is positive shell is negative When the external power is cut off the system will send SMS Power changer off
12. ng SMS to the number and then make alarm call Answering the call the user can hear the recorded message press to hear it again When alarming user can listen in by pressing 3 1 When alarming user can talk to people at the alarm scene by pressing 4 1 Note For normal use if there is built in battery when external power fails or recovers the host will send messages to inform users 12 The message content power change off on year month day hour minute second Control the host with remote controller The remote controller has 4 keys Out Arm Home Arm Disarm Emergency Out Arm Disarm Home Arm Emergency 1 OutArm Press the Out Arm button on the remote controller the STATUS indicator on the main panel flashes in orange 10 seconds later it will turn green with slow flash The system enters Out Arm mode and all the detectors will be in working status 2 Home Arm Press the Home Arm by button the STATUS indicator on the main panel flashes in orange 10 seconds later it will turn green with fast flash Detectors inside the house in inner defense zone will not work only the detectors outside the house in outside defense zone will work so 13 that people inside can move freely but others who break in from outside will trigger the alarm 3 Disarm Press Disarm button the system will enter into disarmed status the STATUS indicator on the main
13. panel is green 4 Emergency When there is an emergency press the Emergency A button on the remote controller the system will alarm immediately no matter it is in arm or disarm status V Components list 1 Basic kit Main panel 1 pc Remote controller 2 pcs PIR sensor 1 pc Door sensor 1 pc Siren 1 pe Power adapter 1 pc Antenna 1 pc User manual 1 pc 14 2 Additional sensors Signal Repeater Glass Sensor Wireless Smoke Detector Fai S Wireless Outdoor Siren with flash FEES Wireless keypad 6 lee at 5 Si Panic Button Remote Controller gt Wireless Pat Gas Detector Immune PIR Detector Optional sensors detectors are packed separately You can choose according to your specific requirements Typical house configuration External Sirens Doorfwindow Garage Smoke PIR Movement Detector Detectors Se J 15 VI Technical Parameters Main Panel Power 9V 12V DC GSM frequency 900 1800 1900MHz Receiving code ASK Receiving frequency 315 433MHz Wireless distance no obstacle 100m Wireless detectors 16 Wire detectors 3 Working temperature 10 C 40 C Wireless Door Window Detector Power Supply DC12V built in 12V battery Static Current lt 20uA Transmission Current 15mA Transmission Frequency 315 433MHZ 0 5MHZ Transmission Distance No obstacle 80m Alarm Distance 15mm Working Condition Temperature 1
14. r 3 The accessory has not been coded to the panel 20 Arm the unit Operate after 30 seconds Set the number again according to the manual Adjust the installation place of the door sensor Activate the PIR Check code again Clean the rust Change battery Change battery Set it again according to the operation manual 1 Replace the battery 2 Pull out the antenna of the accessory and the main panel and adjust the position 3 Code it to the main panel
15. resents zone 4 How to trigger the detectors Door sensor separate the two parts PIR detector move across the detector remote controller press any key on it Note door window sensor is for external zone PIR sensor is for inner zone Press Out Arm key all detectors in external and internal zones will be in arm status Press Home Arm key only the detectors in external zones will be in arm status 11 2 Delete detectors If wireless detector eg remote controller is lost you need to delete the lost detector for your home security Press RESET key then power on 10 seconds later the STATUS LED changes from orange to red and then from red to orange again At this time the system restore to original status password is 123456 all the detectors are deleted For normal use the wireless detectors must be code to the host according to adding detectors methods If you want to delete wireless sensors in a certain zones you can send SMS password defense zone serial number50 65 For example 123456 50 it means deleting the sensors in zone 50 VI Operation instruction When the host is powered on and disarmed users can use remote controller Out Arm Home Arm key or send message 123456 1 1 to arm Under arming status the green light flashes Triggering any wired or wireless detectors the host will make alarm 1 If there are phone numbers stored to receive SMS the host will send the correspondi
16. us the system time will be the same as the time of GSM base station 5 Audio message recording Users can record geographical location home address information as alarm audio message which will be played when alarming Recording operation Press the record key for 2 seconds until the light RECORD on and then speak to the microphone which embedded at the left part of the host 10 seconds later the light RECORD will be off the system exits recording status automatically 10 V Add or delete detectors 1 Add new detectors The PIR door sensor and the remote controller in the standard kit have been coded to the main unit If you want to add more wireless sensors please refer to the following instructions a Internal zone detectors In normal working status press RESET key for 2 seconds the STATUS LED turns red then trigger the new detector If the LED flashes one time it means the operation is confirmed 20 seconds later the host will exit automatically and turns to normal working status External zone detectors In normal working status press RESET key for 2 seconds the light turns red then press RESET key again the light turns from red to orange trigger the sensors If the LED flashes one time it means the operation is confirmed 20 seconds later the host will exit automatically If there are 3 detectors stored they represent wireless zones 1 3 if you add a new detector this detector rep
Download Pdf Manuals
Related Search
Related Contents
TECDIS IME EN wo Furuno rev 1_9 H2O Audio iN2 User's Manual User Manual LO + DESTACADO Radio Shack 49-1010 User's Manual User`s Guide Miele G 6105 SCU CLST Futura Crystal Operating and Installation Instructions Descargar en PDF - Trapo de limpieza RiskyProject Administrator`s Guide Copyright © All rights reserved.
Failed to retrieve file