Home
Trans-Power V-Display User Guide
Contents
1. DISPLAY should try to communicate with Press the Stop key to select the drive address Displayed when selecting the V DISPLAY ID 1 or 2 so that two V DISPLAYs can be connected to a single drive or network of multiple drives Select V DISPLAY ID TROUBLE SHOOTING Select drive address The V DISPLAY failed to successfully XX communicate with the specified drive displayed after address in the network SCAN message Check that the RJ45 data cable connection is correct Check that the drive with address XX is available in the network If XX gt 1 and only one V DISPLAY is connected then check the V DISPLAY device number make sure the number is 1 This normally occurs when there are two V DISPLAY units in the same drive network and both of them have the same device number Check and change the device number of one V DISPLAY This normally occurs when the user plugs a second V DISPLAY into the drive network Change the device number of one of the V DISPLAY units Communication link between the V DISPLAY and drive has failed during operation Check the electrical connection and make sure the cable is connected correctly between the V DISPLAY and the drive Press STOP button to enable the V DISPLAY to search for the drive again Display Err id on power up Display Err id during normal operation Display SC OBS
2. ART key again The motor will reverse its direction of rotation Press the STOP key to decelerate the motor to standstill Whenever the drive is started it will start with a positive soeed unless the direction is negated by the digital inputs on the user terminals CHANGING THE DISPLAY LANGUAGE V DISPLAY supports multiple languages for the displayed text To select a different language simultaneously press the Start and Up keys A list of available languages will be displayed which can be selected using the Up and Down keys To activate the chosen language press the Navigate key DRIVE FAULT MESSAGES AND TRIP CODES In the event of a drive fault or trip the V DISPLAY will display the fault code information from the connected drive For a full list of the trip codes and diagnosis and remedy information please refer to the relevant drive User Guide V DISPLAY DISPLAY MESSAGES V DISPLAY uses various display messages to indicate different working status See the following table for more information Scanning for Drive The V DISPLAY is searching for the drive Load The V DISPLAY has found the drive in the network and is loading the initialisation information from the drive drive and V DISPLAY has failed Select Language Displayed in the language selection screen with a list of available languages Press the Navigate key to select a language Select drive address Displayed when selecting the address of XX the drive that the V
3. OPAD TP_V1 0 USER INTERFACE parameter edit mode and to store parameter changes parameter values in parameter edit mode parameter values in parameter edit mode RESET STOP When drive is in trip mode this button is used to reset a tripped drive When operating in Keypad mode this button is used to stop the drive when enabled and running START When operating in Keypad mode the button is used to start a stopped drive or to reverse the direction of rotation if bi directional keypad mode is enabled See drive user guide for more information Allowed System Configurations Depending on the requirement of the application V DISPLAY can be used in the following different ways One V DISPLAY with one drive Ie One V DISPLAY with multiple drives up to 63 max 3 E zj Two V DISPLAYs with multiple drives up to 63 max E 3 p Gow S Hl Je Irrereraserl Ea EASY STARTUP To setup the drive communication address By default the V DISPLAY will try to communicate with the drive that has Address 1 in the network after powering up for the first time The V DISPLAY will display Scanning for Drive 01 after power up which indicates that the V DISPLAY is searching for the drive with the correct drive address in the network Once the drive has been found the message Load will be displayed on the V DISPLAY which indicates that the V DISPLAY is reading the configuration informatio
4. P 31 Oorl1 Whilst the drive is stopped press the STOP key The value of the digital potentiometer will be displayed indicating target speed Use the UP and DOWN keys to select the required target speed Press the STOP key to return to the real time display showing Stop or the START key to start the drive ramping up to the target speed To vary the speed in real time in keypad control mode Press the START key The drive will ramp up to the preset speed set in the digital potentiometer assuming P 31 1 Press UP to increase speed The drive will run forward increasing speed until the UP button is released The maximum speed is the speed set in P 01 Press DOWN to decrease speed The drive will decrease speed until the STOP button is released The minimum speed is the speed set in P 02 Press the STOP key to stop the drive The drive will decelerate to stop at the selected deceleration ramp The display will finally show Stop at which point the drive is disabled Pressing the START key once more results in the drive running back up to the speed at which it was previously running assuming P 31 1 To reverse direction of rotation with P 12 2 Set the following parameter values to select keypad mode with reverse direction enabled P 12 2 Press the START key The drive ramps up to the preset speed as set in the digital potentiometer assuming P 31 1 Press UP or DOWN to increase or decrease the speed Press the ST
5. VDISPLAY OLED Remote Keypad Option Module User Guide Installation and Operating Instructions DECLARATION All rights reserved No part of this User Guide may be reproduced or transmitted in any form or by any means electrical or mechanical including photocopying recording or by any information storage or retrieval system without permission in writing from the publisher The manufacturer accepts no liability for any consequences resulting from inappropriate negligent or incorrect installation or adjustment of the optional operating parameters of the drive or from mismatching of the drive to the motor The contents of this User Guide are believed to be correct at the time of printing In the interests of a commitment to a policy of continuous improvement the manufacturer reserves the right to change the specification of the product or its performance or the contents of the User Guide without notice WARRANTY The product carries a 2 year warranty valid from the date of manufacture Complete Warranty Terms and Conditions are available upon request Contact Details Internet www transpower com Phone 1 800 526 2626 Kaman Industrial Technologies Part No OPT 2 OPPAD TP OPT 2 OPPAD TP SKU Number 400188062041 SAFETY VDISPLAY is designed to be used in conjunction with the V Drive It is intended for professional incorporation into complete equipment or systems The drive must be installed correctly to prevent a saf
6. an j k 90mm kismm l 81mm THROUGH PANEL MOUNT The panel on to which the VDISPLAY is to be mounted should be cut out in accordance with the diagram below ELECTRICAL INSTALLATION Electrical Interface The VDISPLAY uses a standard RJ45 8 Way connector as its electrical interface which provides a simple solution for the user to setup their system using a standard RJ45 8 Way data cable The signal layout of the connector is as follows RJ45 Interface Signal Layout Cable Requirements Standard 8 way data cables with plugs are available from your local Trans Power stockist on request If the data cable is made up on site ensure that the connection pin out is correct Pin 1 to Pin 1 through Pin 8 to Pin 8 Incorrect cable connection may damage the drive Extra care should be taken when using third party cable System Setup The drive provides the 24V power supply to the VDISPLAY via the RJ45 connection Once the physical connection has been setup the system is ready to operate See picture below Note The location of the RJ45 connector on the drive will vary depending on the drive range and model O L RJ45 Port Power The manufacturer adopts a policy of continuous improvement and whilst every effort has been made to provide accurate and up to date information the information contained in this User Guide should be used for guidance purposes only and does not form the part of any contract 8 0 2
7. communicate with the same drive or different drives When using two V DISPLAYs simultaneously on a network the user must change the V DISPLAY Device Number on the second V DISPLAY to ensure correct operation All V DISPLAY units are set to Device Number 1 by default To change the Device Number press the NAVIGATE STOP and DOWN buttons together The message Select V DISPLAY ID xx xx 01 or 02 will be displayed The User can then use the UP or DOWN buttons to change the V DISPLAY Device Number to 1 or 2 as required Press the STOP button to return to normal operation Note e The V DISPLAY Device Address should only be changed to 2 if 2 V DISPLAY units are connected on a network A V DISPLAY with Device Number 1 must always be present for the network to function correctly REAL TIME OPERATION Once the communication has been established between the drive and V DISPLAY the user can operate and monitor the drive by using the control buttons on the front panel of the V DISPLAY To monitor or change a parameter value e Press and hold the NAVIGATE key for more than 1s when the drive is displaying Stop The display changes to the first parameter in the drive parameter menu Press and release the NAVIGATE key to display the value of the parameter to be edited Change to the required value using the UP and DOWN keys Press and release the NAVIGATE key once more to store the change Press and hold the NAVIGATE key for more than 1s to
8. ere needed Within the European Union all machinery in which this product is used must comply with Directive 98 37 EC Safety of Machinery In particular the electrical equipment should comply with EN60204 1 GENERAL SPECIFICATION Compatible Drives V Drive Signal Interface Standard 8 way RJ45 connector Supply Input 24V 10 DC 30mA RS485 signal Industry standard 2 wire 5V differential Environmental Operational 10 50 C Storage 40 C 60 C Relative Humidity lt 95 non condensing Protection rating IP55 Max cable length 25m 82 5ft shielded twisted pair MECHANICAL INSTALLATION WARNING e When installing the VDISPLAY all drives should be disconnected and ISOLATED before attempting any work High voltages are present at the terminals and within the drive for up to 10 minutes after disconnection of the electrical supply The drives should be installed by qualified electrical persons and in accordance with local and national regulations and codes of practice e Refer to the relevant drive user manual for further details CAUTION e Carefully inspect the VDISPLAY before installation to ensure it is undamaged e Store the VDISPLAY in its box until required Storage should be clean and dry Temperature range 40 C to 60 C e Install the VDISPLAY on a flat flame resistant vibration free surface e Flammable material should not be placed close to the VDISPLAY DIMENSIONS 110mm 102mm
9. ety hazard The drive uses high voltages and currents carries a high level of stored electrical energy and is used to control mechanical plant that may cause injury Close attention is required to system design and electrical installation to avoid hazards in either normal operation or in the event of equipment malfunction System design installation commissioning and maintenance must be carried out only by personnel who have the necessary training and experience They must read carefully this safety information and the instructions in this and the drive User Guides and follow all information regarding transport storage installation and use including the specified environmental limitations Please read the IMPORTANT SAFETY INFORMATION below and all Warning and Caution boxes within this document SAFETY NOTICES WARNING is given where there is a hazard that could lead to injury or death of personnel CAUTION is given where there is a hazard that could lead to damage to equipment IMPORTANT SAFETY INFORMATION Safety of machinery and safety critical applications The level of integrity offered by the VDISPLAY drive control functions for example stop start forward reverse and maximum speed is not sufficient for use in safety critical applications without independent means of protection All applications where malfunction could cause injury or loss of life must be subject to a risk assessment and further protection provided wh
10. n from the drive Usually it will take 1 2 seconds for the V DISPLAY to read this information After the data has been loaded the V DISPLAY will display the drive real time status If the V DISPLAY cannot find the drive in the network i e there is no drive in the network with address equal to 1 the V DISPLAY will display Select drive address 01 The user can then adjust the address from 1 to 63 by using the UP or DOWN buttons on the V DISPLAY Once the address has been changed to a value to match that of a connected drive the STOP button must be pressed to enable the V DISPLAY to search for the drive again Working with Multiple Drive Networks When the V DISPLAY is used on networks with multiple drives the user can change the drive address to set up communication with another drive in the same drive network at anytime Briefly pressing the STOP and DOWN buttons together results in the message Select drive address xx being displayed where xx represents the present drive address Use the UP or DOWN button to select the desired drive address After selecting the new address pressing STOP and DOWN button together again will result in V DISPLAY establishing communications with the drive that has this address NOTE For detailed parameter listing and functional setup please refer to the corresponding drive user guide Networks with 2 V DISPLAYs connected A maximum of 2 V DISPLAYs can be connected within the same drive network to
11. return to real time mode The display shows Stop if the drive is stopped or the real time information e g speed current or power if the drive is running DRIVE OPERATION To change parameter group Ensure that extended parameter group access is enabled The default extended parameter access code is 101 and this should be entered in P 14 to enable the extended parameter group access Enter parameter edit mode with parameter number PX XX displayed Press NAVIGATE button and then simultaneously press and release the UP or DOWN key to change the parameter group number until the required parameter group is displayed Locking access to the parameters e To prevent unauthorised access to the parameters via the V DISPLAY set the following parameter values P 38 1 Once this parameter has been set access to parameters via the V DISPLAY will be prevented e The operational information e g speed current power etc can be still accessed as normal and the drive can still be controlled from the keypad e To unlock parameter access change parameter listed above back to 0 via the drive keypad directly Pre setting target speed in keypad mode Set the following parameter values P 12 1or2 Setting a value of 1 enables keypad mode with forward direction only whilst a value of 2 enables keypad mode with forward and reverse rotation Ensure the following parameters are also set to enable the drive to start from the keypad speed
Download Pdf Manuals
Related Search
Related Contents
Weider WEEVSY2996 User's Manual Copyright © All rights reserved.
Failed to retrieve file