1. 64 8 APPENDIX C XA100 BNC INPUT OVERVOLTAGE PROTECTION ee eren nennen 65 9 APPENDIX D XP100 FAN UNIT FOR DP214 DP235 DP240 UNITS eere eere 66 10 APPENDIX E XP101 FAN UNIT FOR DP DIGITIZERS OBSOLETE e ee eee 67 11 APPENDIX F XP103 FAN UNIT FOR THE DP FAMILY OF MODULES 68 User Manual Family of 8 bit Digitizers Page 4 of 66 acqiris 1 Out of the Box 1 1 Message to the User Congratulations on having purchased an Acqiris data conversion product Acqiris Digitizers are high speed data acquisition modules designed for capturing high frequency electronic signals To get the most out of the products we recommend that you read this manual carefully We trust the product you have purchased will meet with your expectations and provide you with a high quality solution to your data conversion applications 1 2 Using this Manual This guide assumes you are familiar with the operation of a personal computer PC running a Windows 95 98 2000 NT4 XP or other supported operating system It also assumes you have a basic understanding of the principles of data acquisition using either a waveform digitizer or a digital oscilloscope The manual is divided into 5 separate sections To understand the elements of operation for the module it is essential that you read them all Chapter 1 OUT OF THE BOX describes what to do when yo
2. Spacer B User Manual Family of 8 bit Digitizers Page 66 of 66 acqiris 10 Appendix E XP101 Fan Unit for DP Digitizers Obsolete Specification and Assembly Instructions SPECIFICATIONS Airflow 16 m3 h typical speed 6500 rpm maximal noise 30 dB A Nominal Voltage 5 VDC Power input 2 1 W With electronic protection against reverse polarity impedance protected against blocking and overloading Operating temperature 0 C to 70 C Life expectancy at 25 C 50000 hours Safety approvals CE VDE UL and CSA Materials Box of stainless steel and fan of fiberglass reinforced plastic PBT housing PA impeller HOW TO INSTALL REMOVE THE FAN ON A DIGITIZER 1 Remove the digitizer from the PC prior to installing or removing the fan unit 2 Twist the fan s cable a few times in order for the 2 wires to stay together 3 Introduce the cable between the spacers A and B at the back of the digitizer 4 Push the fan unit into the back of the digitizer so that the two springs lock into place 9 Insure that the two springs are safely attached behind the two spacers and that the fan s box is in contact with the digitizer cover 6 Connect the fan s cable as shown in the figure below The position of the power connector can vary between different digitizer models 7 To remove the fan unit first unplug its power cable and then press on both fan springs and pull it away from the digitizer C
3. Offset Voltage FS 2 to Offset Voltage FS 2 Signals going outside of the FSR will be clipped and data values for the clipped portion of a signal should be regarded as erroneous The maximum input voltage for 50 Q input impedance is 5 V The maximum input for 1 MQ input impedance is 100 V dc ac except for the DC2x1A AR models where it is 300 V dc ac 3 2 7 Vertical Resolution The digitizers described in this manual use an ADC system with 8 bits of vertical resolution 256 levels The dynamic range of the ADC covers the Full Scale Range FSR of the Input Voltage setting For example if the Input Voltage is set to 1 V then the ADC resolution is equivalent to 3 91 mV To obtain the best dynamic range from the ADC care should be taken to ensure that the input signal varies over more than 50 of the Input Voltage FSR setting 3 2 8 DC Accuracy and Linearity The DP and DC Series digitizers use low noise front end electronics in order to ensure voltage measurement is made with accuracy and precision DC voltage accuracy at 0 V offset is better than 2 1 typical of the input voltage full scale The differential linearity is better than 0 7 LSB 0 8 LSB for DC135 DC140 digitizers and 0 9 LSB for other DC271 FAMILY digitizers 3 2 9 Using Probes The 50 Q and 1 MQ input impedance settings make it possible to use Acqiris digitizers with a wide variety of probes The 50 Q setting is most commonly used for active
4. the t in the right one The times are in ps The Show Parameters option activates a display of pulse parameters 10 for each active channel Inactive channels will have parameter values of 0 0 The parameters will be calculated in a model in which the distribution of measured voltages has two distinct peaks If this condition is not satisfied the results will be unreliable 4 10 Display Features Display features in the Options menu include items for e turning the waveform display off by de selecting Display Waveforms e overlaying segments of a sequence e connecting displayed data points e modifying the display refresh rate e displaying the internal temperature of the currently selected module User Manual Family of 8 bit Digitizers Page 57 of 68 acqiris 4 11 Command Line Switches When starting the AcqirisLive application the executable s name in the command line can be followed by one or more switches to change the running conditions Syntax The syntax of the command line is the following pathNAcqirisLive exe a c d h i 1 m 7n p 7s t v 7x Available Switches List of available switches a start in Averager mode C no initial calibration d use DMA for data transfers default h high priority process default i use acquisition interrupts low priority process m medium priority process n no DMA for data transfers p Use acquisition polling
5. 3 3 3 Single and Sequence Acquisition Modes Digitizers acquire waveforms in association with triggers Each waveform is made of a series of measured voltage values sample points that are made by the ADC at a uniform clock rate To maximize sampling rates and utilize memory as efficiently as possible the digitizers include both Single and Sequential storage modes The Single Acquisition mode is the normal operation of most digitizer products In this mode an acquisition consists of a waveform recorded with a single trigger The user selects the sampling rate and acquisition memory size and sets the number of segments to 1 default value The Sequence Acquisition mode allows the capture and storage of consecutive single waveforms Sequence Acquisition mode is useful as it can optimize the digitizer s sampling rate and memory requirements for applications where only portions of the signal being analyzed are important The mode is extremely useful in almost all impulse response type applications RADAR SONAR LIDAR Time of Flight Ultrasonics Medical and Biomedical Research etc In Sequence Acquisition mode the acquisition memory is divided into a pre selected number of segments Waveforms are stored in successive memory segments as they arrive Each waveform requires its own individual trigger The memory can be divided into any number of segments between 2 and 200 up to 8000 segments with options M32M M16M M8M and M4M 4000 segments
6. 20 Setup will prepare a registration e mail in your e mail client application upon termination of the setup procedure You can then decide whether or not you wish to send it You may also add comments Uncheck the box if you do not want to register your installation User Manual Family of 8 bit Digitizers Page 19 of 66 i Acqiris Software Setup Acqiris Software Installed Successfully Setup iz complete and your software is now installed Thank vou for choosing an Acqins Product Please click Finish ta exit this installer 21 Click Finish The software installation is now complete 22 You can now either accept the suggestion to restart the computer or you should shutdown your computer and proceed with the hardware installation jie Acqiris Software Setup Hestart Computer Y aur computer needs ta be rebooted You must reboot the system to complete the installation f vou do not reboot now you will need to do sa later in order ta complete the installation we Yes restart my compter now User Manual Family of 8 bit Digitizers Page 20 of 66 acqiris 2 3 Installing the Software for Linux The Acqiris Software is ready to install and run on Linux systems with either RedHat versions 8 0 Kernel Version 2 4 18 14 or 9 0 Kernel Version 2 4 20 8 Fedora Core 3 Kernel Version 2 6 9 1 667 and 2 6 9 1 667smp or Debian Sarge Kernel Version 2 6 8 2 686 The driver and the library were compiled with GN
7. Page 45 of 68 acqiris 3 11 2 Environmental and Physical The modules have a Declaration of Conformity according to ISO IEC Guide 22 and EN45014 and CE Marks of Compliance The American Standard MIL PRF 28800F has been used as the source for many of the characteristics specified below Those indicated with a are compatible with Class 3 as defined in that standard The front panels of the CompactPCI modules are in compliance with the IEEE 1101 10 standard Operating Temperature 0 to 40 C for the DC271 FAMILY modules 0 to 50 C all other modules The above values are for the ambient temperature of the room or equivalent where the PC or CompactPCI crate is located The temperature as measured on the board may well be significantly higher On board temperatures above 60 C should be avoided Relative Humidity 5 to 9596 non condensing Dimensions All DP modules conform to the PCI standard The DP214 DP235 DP240 and DP211 DP212 DP111 modules are 107 mm x 210 mm and require a long card slot If used with the XP103 fan they can be adjusted to conform to the full 342 mm length All other cards require a short card slot 107 mm x 175 mm An XP100 fan will add 45 mm to the length of any card The DC110 DC140 and DC135 conform to the 3U CompactPCI standard 100 mm x 160 mm x 20 mm All other DC modules conform to the 6U CompactPCI standard 233 mm x 160 mm x 20 mm Shock 30 G half sine pulse Vibration 5 500 Hz
8. User Manual Family of 8 bit Digitizers Page 43 of 66 acqiris The ASBus is intended to connect modules of the same type i e of the same model number although some exceptions to this rule might be possible If modules with the same model number but different memory length options are connected only the shortest memory length can be used The ASBus connector is located on the front panel of each module Bridges are used to connect adjacent modules for synchronization which is then activated through software by defining a master module and the trigger source Up to 7 modules may be synchronized with the ASBus More detailed information and the commands required to set up the ASBus clock and trigger distribution are included in the Programmer s Guide and Reference manual 3 8 Special Front Panel Inputs and Controls DC271 FAMILY MMCX CLK IN 50 Q External Reference or External Clock Input MMCX I O A User configurable see below MMCX TR OUT Signal occurs after an accepted TRIGGER MMCX I O B User configurable see below The I O A and I O B signals are 3 3 V compatible CMOS This means that on input low is 0 7 V and high must be in the range 1 7 V 5 0 V An unconnected signal will be high This definition ensures TTL compatibility On output the low level will be in the range 0 V 0 7 V and the high level in the range 1 7 V 3 3 V for HiZ The high level output will typically give 0 8 V into 50 O The I O A or B con
9. r start in transient recorder digitizer mode S simulation mode t temperature update off V show acquisition state X disable automatic multi instruments Operation Mode Acqiris averagers can be operated in Averager Mode or in standard Digitizer Mode AcqirisLive operates in either mode but since these are mutually exclusive only instruments that support the chosen mode are accessible in any given mode E g only averagers are accessible in Averager Mode while both digitizers and averagers are accessible in Digitizer Mode The operation mode can be switched within the application By default AcqirisLive starts in Digitizer Mode Calibration Before operation the instruments must undergo an internal calibration As this calibration can only proceed sequentially for each channel the initialization time of AcqirisLive can become significant for systems with many channels Therefore it can sometimes be desirable to be able to start the application quickly by skipping the calibration which must then be done manually before collecting correct data DMA Data Transfers By default data transfers on the PCI bus between the digitizer memory and the PC are done in DMA Direct Memory Access mode which allows the fastest transfer speeds up to about 130 MB s peak 100 MB s sustained acquisition data rate These very high data rates are not well supported by all hardware configurations PC motherboard and system hangs due to endless
10. convenient program for capturing displaying and archiving captured data into the format of your choice binary or ASCII AcqirisLive is provided free with the purchase of any Acqiris Digitizer Acqiris supplies drivers on the CDROM for National Instruments LabWindows CVI LabVIEW Microsoft Visual C and Visual Basic Acqiris also provides some examples GetStarted applications as a guide or starting point for programmers developing their own applications to interface with the DC or DP series digitizer cards When you start AcqirisLive a display like that shown below appears Instrument Control m jej xl Waveform Display Sisi xj Instrument Setup Store Options Help View Zoom E 17157 crate 3 pos 2 Finder qo 0 Dspl s B Dieet en Ad Input Voltage Scale Coupling Bs BE oc Input Voltage Offset Impedance Halooo oov o img Trigger Ady Edge class Source DC271 Ch1 i Coupling O00 0 00 oc Delay BR Slope Y 0 00E 0 0 00s TN Timebase 100 ns Div Memory MAX 50000 50 0 K samples 4 1 00 segments may Sampling Interval Rate 1 0000 ns 1 0000 GS s Acquisition STOPPED U ACG0 5 AUTO NORMAL SINGLE STOP Trig Time 1 00 GS s 100 ns Div 10 59 10 Ready 10 59 23 Starting calibration 10 59 50 DC271 recalibrated ald AcqirisLive displays two independent windows a control window and a display window The control window contains functions that allow
11. the first time the system is started the Plug amp Play system will automatically detect the Acqiris hardware briefly display a New Hardware Found dialog box and start the Add New Hardware Wizard displaying the window shown below User Manual Family of 8 bit Digitizers Page 23 of 68 acqiris Add New Hardware Wizard Thiz wizard searches for new drivers Far PCI Card device driver is a software program that makes a hardware device work Lancel To proceed with the installation click Next The following window will appear Add N ew Hardware Wizard What da vau want Windows to do Search for the best driver for your device Recommended C Display a list of all the drivers in a specific location so you can select the driver you want Cancel To proceed with the installation click Next The following window will appear User Manual Family of 8 bit Digitizers Page 24 of 68 acqiris Add New Hardware Wizard Windows will search Far new drivers in its driver database on Your hard drive and in any of the following selected locations Click Next to start the search Floppy disk drives CD ROM drive Microsoft Windows Update I Specify a locatior CSwINDOWSNINF Browse Lancel To proceed with the installation keep the defaults and click Next The following window will appear Add New Hardware Wizard Windows driver file sear
12. 5 5 1 and Linux RedHat 8 0 Kernel Version 2 4 18 RedHat 9 0 Kernel Version 2 4 20 or Fedora Core 3 Kernel Version 2 6 Debian Sarge 2 6 8 Linux kernel driver source code is available for compilation Hard Drive Space 20 Mbytes Minimum CD Drive or any method to copy Acqiris Software installation files from CD to the hard drive such as LAN floppy drive etc User Manual Family of 8 bit Digitizers Page 7 of 66 acqiris ETS The example files are for Microsoft Visual Studio 6 0 with Phar Lap ETS 12 0 support LabVIEW The Acqiris LabVIEW driver is available for National Instruments LabVIEW versions 6 0 6 1 7 0 or 7 1 LabVIEW RT The Acqiris LabVIEW RT driver is available for National Instruments LabVIEW RT version 7 1 or higher The VISA driver must be version 3 0 or higher MATLAB The Acqiris MEX interface can be used with MathWorks MATLAB 60 5 or a newer vesion Alternatively to successfully use the Acqiris MATLAB Adaptor you must have at least MathWorks MATLAB 6 5 with the Data Acquisition Toolbox Visual BASIC The interface files and examples are available for Microsoft Visual Basic versions 5 or 6 and the interface files only for NET Tornado The example files are useable with Wind River Tornado 2 2 1 1 10 Transport amp Shipping CAUTION Cards can be safely transported in their original shipping packages DC cards can be transported when properly mounted in a CompactPCI crate The transport of DP card
13. Acqiris acquisition module in one of the last 7 slots and with the PC running under Windows 2000 NT or XP will not need the GeoMapper Users who do not need GeoMapper do not need to read this chapter any further 5 2 When should the GeoMapper Application be used The application needs to be used whenever the bus or slot configuration of the system changes in a fundamental way The most obvious trouble symptom is that an expected multi Instrument was not found Alternatively the driver can issue error messages that the AcqirisLive application and other programs will see Among them are Modules are not contiguous in ASBus combination ACOIRIS ERROR MODULES NOT CONTIGUOUS ASBus Candidate Modules not on same bus ACOIRIS ERROR MODULES NOT ON SAME BUS AcqGeo map file is invalid or corrupted ACQIRIS ERROR INVALID GEOMAP FILE In all of these cases the GeoMapper application should be run to ensure that the map file is up to date If desired the GeoMapper application will generate a default configuration in which it allows the driver to make all of the choices This is done by specifying None Disable GeoMap as the desired configuration in Stepl Crate count of the application 5 3 How to run GeoMapper After software installation you will find GeoMapper in the AcqirisApp directory of the installation directory After being started the program will learn about the Acqiris devices present and then show a screen like the one below RS A
14. Aq_GetStarted m example mex help Aq_ m help files for all routines ReplacedSystemFiles directory with old versions for possible recovery not for Windows XP msvcp60 dll msvcrt dll tornado directory with sample program GetStarted VxW cpp Source file for Tornado sample program GetStarted VxW wpj Tornado Project file for Tornado sample program GetStartedVxW wsp Tornado Workspace for Tornado sample program VB directory with the files needed for either a 12 bit digitizer or 8 bit digitizer Visual Basic program AcqgirisShow12 frm Source code for main window of VB sample program AcgirisShow12 vbp Visual Basic project file of VB sample program AcqirisShow12 vbw VBW file of VB sample program AcqirisShow8 frm Source code for main window of VB sample program AcqirisShow8 vbp Visual Basic project file of VB sample program AcqirisShow8 vbw VBW file of VB sample program DevCtrlForm12 frm Source code for device control dialog box of VB sample program DevCtrlForm8 frm Source code for device control dialog box of VB sample program VC directory with the files needed for either an averager or a digitizer VisualC program GetStartedAvgVC cpp C source code of VC sample program GetStartedAvgVC dsp VisualC2 6 0 project file of VC sample program GetStartedVC cpp C source code of VC sample program GetStartedVC dsp VisualC 6 0 project file of VC sample program GetStartedVC rc R
15. C Program FileszsM ational InstrumentssL abi TIE WwW PT nst libe 9 Applications gt C Program Files amp cginss amp egqinis amp pp AcqrnsLime APs Derma Firmware gt C Program FilessAcqinssfirmesare User manuals gt C Program Files ss amp cqinissmanuals 17 You are now ready to install You may still go back to any previous screen to modify your selection Click Install when ready User Manual Family of 8 bit Digitizers Page 17 of 66 i Acqiris Software Setup Heady to Install Y au are now ready to install amp cqins Software Click Nest to continue Setup now has enough information to start installing the software Fou would like ta make any changes before continuing click Back To abort the Installation click Cancel When you are ready to start installing the software click on the Install button 18 Setup will now copy the files and make the necessary changes to your system When done an information screen will be displayed Please read this carefully jie Acqiris Software Setup IMPORTANT Information For First fime Installation Please read the information below and click Next After completion of the software installation you should shutdown your computer and install the digitizer madule s Details on this are green in Chapter 2 of uour User Manual Please pay particular attention to the following Take proper precautions to avoid electrostatic damage to the cards Power your crate befo
16. Ne a aE d 222 2 2222 BRESSE on H LEPTH RER L ELLA Un E 5 LLL P XA001 Battery Backup D User Manual Family of 8 bit Digitizers Page 64 of 68 acqiris 8 Appendix C XA100 BNC Input Overvoltage Protection Specifications and User Instructions The XA100 Acgiris option contain two elements 3dB BNC Attenuator 90V BNC Spark Gap The XA100 overvoltage protection kit allows the digitizers with 50 Ohm only input without high impedance input to withstand a high voltage surge of up to 5 kV XA100 SPECIFICATIONS Frequency range DC to 1GHz Input impedance 50 Ohm Attenuation 3 dB VSWR DC to 1GHz 1 25 Impulse discharge current 8 20 us pulse 10 kA Weight 60 g Length 85 mm ATTENTION BOTH the 90V spark gap and the 3dB attenuator MUST be used in order to absorb very high current In order to limit the input current the attenuator MUST be inserted between the spark gap and the input of the module as shown in the figure below 3dB BNC Attenuator att n jj t o exe j Y Ww N 90V BNC Spark Gap 7 0 a bi M d L U I e LARA e e br QJ d e 2 Digitizer 90V BNC Spark Gap e Input Channel A 3dB BNC Attenuator Input Channel B User Manual Family of 8 bit Digitizers Page 65 of 66 acqiris 9 Appendix D XP100 Fan Unit for DP214 DP235 DP240 units Specification and Assembly Instructions SPECIFICATIONS Airflow 6 m3 h typi
17. T sae babe tfe ie beam 7 WAO Transpo acs MIP Pie ceresna i N N A 8 Ib Maenan iae dti ML ELM ML IM NL IE LM NM ML TAN 8 IR EK IT ITE mmm 8 I5 dusposal ambReeyelm9 uet e saul tuii cba dea canbadesentbe Pacabaemaesbbacsion anh ET 8 Ds INSTALLATION TT TENE 9 k LR YE Tas CaN AN E P scm 9 E E 1C414 Hardware installation Wits eo eR xe cad KES mula edie dated ce ERa NHS hraa 9 2 12 IC414 Windows software installation eeeeeeeeeeeeeeeeeeeeseeee een 9 2 2 Installing the Software under Windows caa TR era NER aga eene 10 elle IV AU Tid EN OS ee EE 10 2 2 2 Multiple VerstOHs zoe tua a umi esten d end ciet Les iesu estera LE 10 2 2 5 nstallattOfi isse sees CURE E A EE c een bd I prepa so a Dea E AE AEEA 11 Za Umnstalhme the Software Tor LIAtboss uu Sor REPRE eased spa dee 21 2 3 Kernel Mode Driver Compilation 21 E E CRT TT 22 2 Da Environment variables for the Firmware eeeeesseeeeeeseeee ens 22 Z4 Installing the FI3EOWAEe iade oti etii o ee EE m OR em nates et Et 22 Z2 XH IR CSU AIO soi ssa mp De ta eaten ar eh oe p EM De e LL CM 23 2 5 1 NY MIN OV E 23 245 2 WIndows cotcateud ito obedece pte obd tuat ness iudei suot CUP 23 2 5 95 Doo Fo 7 092 010 0 Rp MR NR UR EMEN 26 2 5 4 Windows CD TTT 26 2 5 5 I LEO NTA E Decet reca dt fiut acd ttt rtu tn eo Md EDLA 29 2 5 6 MATLA D Per E RE re eee ere 29 20 SbabAME W E nsi ere ne one eee mer eee nr CTE ao aera Oe DTrace
18. Time Interpolator TTI that measures the time from the trigger point to the first sample point This information is essential for determining the precise relation between the trigger or other event of interest and the digitized samples of the signal The approximate TTI resolution 1s also given in the table at the beginning of this section 3 3 5 Timebase Range The timebase range defines the time period over which data is being acquired For example the DC110 has a standard acquisition memory of 128 Kpoints and maximum sampling rate of 1 GS s Therefore at User Manual Family of 8 bit Digitizers Page 40 of 66 acqiris the maximum sampling rate the digitizer can record a signal over a timebase range of up to 130 us approx 130 000 points 1 ns point The timebase range can be adjusted by varying the amount of acquisition memory or the sampling rate of the digitizer 3 3 6 Combining channels The DCI135 DC140 DC241 DC241A DC271 DC271A DC271 AR DP235 DP240 digitizers offer the possibility of combining the converters and their memories from two or four channels to analyze a single input channel With this feature the maximum sampling rate and the maximum amount of acquisition memory can be doubled or quadrupled if all of the input channels are not of immediate interest 3 4 Trigger Normally the trigger settings applied to the digitizer are used to determine the time at which the device will stop acquiring data Some models are also
19. acqiris 5 Running the GeoMapper Application 5 1 Who needs a Geographical Map of Modules The GeoMapper application gives the user the possibility of telling the Acqiris driver crucial details of the physical position of modules when this information cannot be deduced directly It allows the driver to correctly adjust trigger and clock delays between the different modules of an ASBus multi Instrument and arrange the modules in an intuitive order The GeoMapper application has been implemented as a Wizard with the goal of learning the physical position of each module of a multi bus system The driver already knows the logical Bus and logical Slot numbers of each Acqiris unit present However because of varying conventions for the compactPCI slot arrangement on a bus this is not sufficient to determine the physical position Furthermore with the aid of the map the software can ensure that the modules of an Auto defined multi Instrument will be ordered to correspond to increasing physical slot number NOTE The unusual slot numbering convention of the CC121 is documented in the CC121 CompactPCI Crate User Manual The CC10X crates have a simpler slot numbering convention that the Acqiris driver already takes into account CompactPCI Crates from other manufacturers represent an unknown element NOTE The GeoMapper is of use for some ASBus systems in CC121 crates and perhaps crates from other manufacturers CC121 crate configurations with both an
20. capable of a Start on Trigger mode of acquisition see the Programmer s Guide for further details The various trigger settings are outlined below 3 4 1 Trigger Source The trigger source can be a signal applied to either an Input Channel internal triggering or the External Trigger Input For the DCI35 DC140 DC211 DC211A DC241 DC241A DC271 DC271A DC271AR modules a standardized trigger in signal can also be routed via the PXI Bus Star Trigger line The digitizers provide a separate front panel input that can be used as an External Trigger Input The External Input provides a fully functional trigger circuit with selectable coupling level and slope as for the Internal Triggering source The external trigger termination 1 MQ or 50 Q is also selectable on most modules In modules with this feature the circuit also provides an overload protection that will automatically switch the coupling from 50 to 1 MQ if the signal is greater than 5 V DC The DC271 FAMILY digitizers have a fixed 50 Q termination impedance They also allow the same BW limiter selections as can be found for the channels The DC271 Family digitizers external trigger circuit has diode protection against overload In all 50 cases a 5 V limit on trigger signals should be respected although somewhat higher voltages for short time periods will not damage the unit For 1 MQ input signals up to 100 V DC peak AC lt 10 KHz are allowed 3 4 2 Trigger Coupling Tr
21. contact your nearest sales office User Manual Family of 8 bit Digitizers Page 35 of 68 acqiris 3 2 Channel Input 3 2 1 Coupling Both AC and DC coupling modes are available The AC mode couples signals capacitively thus removing the input signal s DC component and filtering out any signal component below 16 Hz for the DC2x1A digitizers 32 Hz for the DC271 Family and 10 Hz for all other models DC mode allows all signal components to be passed through to the digitizer 3 2 2 Impedance The input channels of the DP and DC Series digitizers offer termination in either 50 Q or 1 MQ The 50 O coupling mode offers high quality termination with better than 1 precision It is ideally suited to use with 50 Q transmission lines coax high bandwidth low impedance typically 500 probes or active probes The 1 MQ coupling mode provides a high impedance low load capability that is suited for use with most standard high impedance probes The high impedance mode also features low typically 10 pF see table capacitance that helps to minimize loading effects that can occur when probing high frequency circuits 3 2 3 Input Protection The input amplifiers are fully protected against over voltage signals Input signals up to 300 V for the DC271A DC271AR DC241A and DC211A and 100 V otherwise DC peak AC 10 KHz at 1 MQ and up to 5 V DC at 50 Q can be input without damaging the front end electronics The front end also provid
22. control panel in Transient Recorder mode The input frequency should be keyed into the clock frequency selector outlined in red on the control panel Then the appropriate sampling frequency must be selected in order for the proper timebase to be displayed on the waveform display window The time window displayed can be manipulated by allocating more or less memory to the acquisition The External 10 MHz Reference in AcqirisLive is designed to work either in Oscilloscope mode or in Transient Recorder mode The timebase and sample rate for waveform capture is fully selectable when using the external reference just as it is when using the digitizer s own internal reference clock 4 9 Additional Waveform Information The Options menu also includes possibilities to obtain additional information about the waveform In both cases described below the display will be updated after each acquisition The Show Segment Timestamps option shows a display like the one below ioj x sexe pee Tt gives you the information needed to better understand the trigger EET times of the individual segments of an acquisition By definition the first 2 trigger of an acquisition occurs at t 0 0 There are two columns for each digitizer For the n th row the first column contains the difference ta t 1 and the second column contains ta The top line contains the 3 4 5 6 average value of the t in the left column and the standard deviation of t 8 7
23. input signal has a frequency between 10 MHz and 2 GHz DC271 FAMILY or between 10 MHz and 500 MHz all other models For the Start Stop mode the input signal frequency must be less than 1 GHz DC271 Family or 500 MHz all other models In both cases it must have a minimum amplitude of at least 2V 0 5 V DC135 DC140 DC211A DC241A DC271A DC271AR 1 V all other DC271 Family peak to peak into 50 O at the front of the digitizer The transitions of the clock are defined with the aid of a threshold that is user selectable in the range 2 0 V 2 0 V 3 0 V 3 0 V for the DC240 The signals should not exceed 5 V amplitude For a detailed discussion on the programmed use of the external clock refer to the Programmer s Guide For applications that require greater timing precision and long term stability than 1s obtainable from the internal clock a 10 MHz Reference signal can be used The External Reference is nominally at 10 MHz However frequencies in the range 9 0 MHz 10 2 MHz will be accepted If you do this you may need to correct for the difference in your application since the digitizer and the driver have no way to know about such deviations The amplitude and threshold conditions for an External Reference are the same as for the External Clock If synchronization between several digitizers 1s required the reference signal should be applied to all of them 3 6 Internal Calibration The software drivers supplied by Acqiris include calib
24. probes and low impedance 500 Q passive probes The 1 MQ setting is normally used for high impedance probes While it is possible to use a variety of different manufacturers high impedance probes Acqiris recommends the use of its model P001 Passive Probe The model P001 is matched to the Acqiris digitizers to ensure that effects that can reduce measurement quality such as bandwidth loss and capacitive loading are minimized The P001 features 300 MHz bandwidth 10 MQ input impedance and 10 1 attenuation These specifications make it an excellent choice for most general purpose probing applications Before using any Passive Probe with a digitizer care should be taken to check that the probe has been correctly adjusted refer to the Probe s Calibration procedure NOTE Passive high impedance probes are not suitable for high fidelity measurements above 100 MHz The non negligible 5 10 pF tip capacitance loads the signal causing distortion and or ringing when combined with the ground lead inductance User Manual Family of 8 bit Digitizers Page 38 of 68 acqiris 3 3 Data Acquisition The table below summarizes the characteristics discussed in the sections that follow Model Max Max Default Maximum Maximum TTI Timebase External Sampling CONVER Memor Optional ee Clock Rate TERS PER y Memory y CHANNEL channel ie CHANNELS points Min channel DPl05 soomsis 1 1 fiK 2M 400 s0ps soppm 2V DPl06 soom
25. user information and click Next to continue If the program finds that there is still Acqiris software installed on your machine a warning panel not shown will appear Otherwise the next screen shows jie Acqiris Software Setup Select Module Families Select ane ar more module Families and click N evt to continue Please select one or more module families that pou may want to use below 8 bit and or 10 bit Digitizers 42 bit Digitizers Averagers Analuzers All module families Back Cancel 5 Pick the desired combination of module families and click Next to continue User Manual Family of 8 bit Digitizers Page 12 of 68 jie Acqiris Software Setup Install Manuals Make your choice below and click Mest ta continue Please check the box below if you want access to Acqiris Manuals on your system copy to disk and create shortcuts All of the available User and Reference Manuals will be installed Iw Enable Documentation Installation 6 The screen above will normally allow the documentation to be installed Remove the check from the box if you do not want online access to the manuals 7 The next screen allows you to enable LabVIEW RT Phar Lap ETS and or Wind River VxWorks support By default there will be none but if desired you can install any of them together with Windows support or without Windows support Click Next to continue jie Acqiris Software Setup Se
26. you to manipulate the acquisition parameters of the card In order to display an acquired waveform connect a signal to the input and then select the Auto acquisition mode at the bottom of the control panel A waveform should appear in the display User Manual Family of 8 bit Digitizers Page 47 of 66 acqiris Other controls in the control panel allow you to select the optimal acquisition settings for your particular signal Each of the other control panel functions will be discussed in detail in the following Control Panel Functions section Here is a sample result I xi Waveform Display ox Instrument Setup Store Options Help View Zoom E J 17157 crate 3 pos 2 Feder Lom 19 5098 Dspl s acqiris DC271 Ch1 ses Input Voltage Scale Coupling Bs AC DC Input Voltage Offset Impedance E o oo00 000v 502 IMG Trigger Adv Edge class Source DC271 Ch1 vw Level 1 Coupling O00 o 0ov oc Delay Een 0 00s Timebase a B Memory MAX 50000 50 0K samples E 1 00 segments may Sampling Interval Rate 1 0000 ns 1 0000 G5 s Acquisition NORMAL 1056 53 Acq s Trig Time 1 00 GS s 2 00 us Div NORMAL SINGLE 10 53 10 Ready 10 53 23 Starting calibration 10 59 50 DC271 recalibrated al 4 2 Control Panel and Functions 4 2 1 Control Panel Mode DSO TR In AcairisLive there are two control panel modes available Oscilloscope Mode and Transient Recorder Mo
27. 01 Demo application GeoMapper exe Acqiris GeoMapper application cviauto dll NI software needed by AcqirisLive cvirt dll NI software needed by AcqirisLive cvirte dll NI software needed by AcqirisLive dataskt dll NI software needed by AcqirisLive mesa dll software needed by AcqirisLive cvirte directory containing bin and fonts subdirectories Data directory to be used for saved data files from AcqirisLive or APx01Demo AqSC files created only after 1 run A Bin directory aq dii software needed by MATLAB Adaptor AqDrv4A dll Acqiris Windows Digitizer Driver DLL AqDrv4 fp CVI function panel contains all the driver C functions AgqDrv4 ini Optionally created to indicate where FPGA bit files can be found AqDrvMex dll software needed by MATLAB MEX interface AgISI3 dll software needed by AcqirisLive and MATLAB Adaptor AqRT 4 dll software needed for LabVIEW RT AgqSCI3 dll software needed by AcqirisLive and MATLAB Adaptor CallAcgiris dll software needed by MATLAB Adaptor FactoryInstrumentSettings AqSettinss MATLAB Instrument Settings Configuration file msvcp71 dll msvcr71 dll qt mt332 dll qt mt333 dll Microsoft VC run time Microsoft VC run time software needed by AcqirisLive and MATLAB Adaptor software needed by AcqirisLive and MATLAB Adaptor BinWernel directory only the files needed for your OS will be present acqirv00 vxd Win9x low level driver acqirv04 inf Win9x 2000 low
28. 1 10004 4 14 2 OC27 10000 4 15 1 zsystem slot x Previous The final step is to actuate the Save button so that the final configuration will be memorized and made available to the driver The GeoMapper application will always work with the standard AqGeo map file If you need to have several such files corresponding to different configurations it is up to you to either rename the files or transfer them to other directories in an appropriate manner User Manual Family of 8 bit Digitizers Page 62 of 66 acqiris 6 Appendix A ASBus for CompactPCI PXI Digitizers Specification and User Instructions SPECIFICATIONS ASBus Bridges allow the connection and synchronisation of up to 7 DC series digitizers up to 28 channels Acqiris recommend having the master digitizer in the center of the group in order to obtain the best performance possible Clock synchronization accuracy 100ps Important to ensure the correct operation of the ASBus Bridge it is necessary that each module is securely attached to the crate using the screws provided in the upper and lower handles Failure to install the modules correctly may result in disconnection of the ASBus Bridge due to pin misalignement User Instructions for 2 digitizers ASBus dual termination bridge XB103 User Instructions for 3 digitizers ASBus left termination bridge XB101 ASBus right termination bridge XB102 E User Instructions for 4 to 7 d
29. Acqiris Instruments The instructions below concern LabVIEW RT as used in NI PXI processors The Aq RT inf and AqRT 4 ini files must be uploaded to the target To do this e start the MAX application e right click on the target e select file transfer e select the Aq RT inf file on your host machine and upload To Remote to the LabVIEW RT working directory NI RT system on the target e select the Aq RT ini file on your host machine and upload To Remote to the LabVIEW RT working directory NI RT system giving it the name AqDrv4 ini For Acqiris modules which need FPGA files you should e create the folder firmware in the NI RT system directory using the file transfer application e select the FPGA files from AcqirisDxRoot Firmware you want to copy to the target and upload them into the firmware directory Restart the target after finishing the file transfers User Manual Family of 8 bit Digitizers Page 29 of 66 acqiris Restart the MAX Explorer and you should have Acqiris digitizers detected in your PXI system 2 7 Distribution for Windows 95 98 2000 NT4 XP After a complete installation of Acqiris Software for Windows supports Windows 95 98 2000 NT4 XP the following files and directories should exist in the chosen installation directory jrunin miscellaneous install files AcgirisApp directory AcgirisLive exe AcqirisLive Windows application AP SSRDemo exe AP SSRDemo application APx01Demo exe APx
30. U gcc 3 3 The Kernel Driver source code is available for recompilation for users with other Linux systems The tar file AcqirisLinux tar bz2 should be copied to a local directory e g your home directory and then unpacked by using the following command tar xe AGGIPISLSIDUXUADZ2 The resulting directory AcqirisLinux contains an install script drv install and a graphical Demo program demo AcqirisDemo Before installing the driver you have to put the correct version of the Kernel mode driver into acqirisPCI o By default the version 2 4 18 RHS is ready If this is not what is needed type cp lib modules acqrsPCI o n lib modules acqrsPCI o where the driver is from the following list acqrsPCI 0 2 4 18 14 for Kernel Version 2 4 18 and RH8 acqrsPCI 0 2 4 20 8 for Kernel Version 2 4 20 and RH9 acqrsPCI o 2 4 21 4 EL Red Hat Enterprise Linux version 3 acqrsPCI 0 2 4 21 4 ELsmp for above with SMP acqrsPCI 0 2 6 9 1 667 for Kernel Version 2 6 9 and the Fedora Core 3 acqrsPCI ko 2 6 9 1 667smp for above with SMP acqrsPCI ko 2 6 8 2 686 for Debian Sarge To install the driver and the load script to the system you have to get super user privileges and execute the driver install script by typing cd AcqirisLinux drv install add You can check that the driver is loaded properly with 1smod or dmesg The drv install script has the following additional functionality drv install rem to remove the driver and load script drv install res to restart
31. Voltage Scale Offset and Coupling ss 5 4 2 6 utor qe Hr RE EA 51 FT ACam ton ModE inene EEE E AE Gna nal NEEE A EN 52 4 2 8 Timebasc and L C1 1010 sostener EUER RR atat uestis tenen in ee RF uui was cust UR LE 53 4 2 9 Using digitizers of different models simultaneously sss sese 53 4 2 10 Sco memed MEMO M Dm 53 4 2 11 Display Features Zoom and Persistence s0ssssssssssssesssssssssssssssssessssssssssseseees 54 A Pop lime Menu ot ACOITISETVE vites meta A NERE ex dedita ec ee n Mee LEA 55 due SSODUDOSSpiu id Maddie a nd du eM di Mi eM di m Mai 55 4 5 Store Autostore and Conversion of Waveforms sse eene 55 AO ANNO octets cada dte ui eats id haa us candi cose del 56 4 1 MOMMIES chanBelS a a etos iade as tesi ata e buds p autas ut otio usu et tens 57 4 5 External 10 MHz Reference and External Clock 57 49 Additional Waveform Information a etes ette E ete ege Perte i eto eae ds 57 LAC NECESITE omm 57 c TL Command P SL e S kins esteso etre a a a a a a aa 58 5 RUNNING THE GEOMAPPER APPLICATION cccsssssssssssssssccssssssssssssssscsssssssscssccsssssssssees 60 5 1 Who needs a Geographical Map of Modules sss sese 60 5 2 When should the GeoMapper Application be used sss 60 Jor Howto eric Ooh RR EET m ll m 60 6 APPENDIX A ASBUS FOR COMPACTPCI PXI DIGITIZERS ccce eee eee eee eene eenn 63 7 APPENDIX B XA001 BATTERY BACKUP FOR COMPACTPCI DIGITIZERS
32. a has already been adjusted for gain and offset and can be directly read out as a voltage However it requires roughly twice as much space as Raw ADC value data For the sequential acquisition mode the segment time stamps are also stored when waveforms are saved using the Autostore and Save Waveform functions Data stored in binary format with Autostore must be Data Format Conversion ni xi converted before it can be imported into a data processing Source tolder package or a spreadsheet e g Excel The Data Format em Conversion option is found under the Store menu Select C carsbie Data Browse Data Format Conversion in order to bring up the following C Baw ADE values window The acquisition must be stopped in order to access ye fmpitudes vl this menu SE ee ai LY 1 To convert the binary data simply select the source folder UF Cancel Help where the data is located select the output format and click OK All binary data files found in the source directory will be converted to the desired format If you are writing amplitudes with multiple segments formatting with segments in columns is limited to 200 segments 4 6 Calibrate The Calibrate item in the Options menu leads to a sub menu where a particular type of calibration can be invoked In order to use this item the acquisition must be stopped otherwise the Calibrate option is not selectable The possibilities are Calibrate instruments to perform a sel
33. acqiris XZ001 USER MANUAL FAMILY OF 8 BIT DIGITIZERS For Use with DP and DC Series Digitizers Models covered DP105 DP106 DP110 DP111 DP210 DP211 DP212 DP214 DP235 DP240 DC110 DC135 DC140 DC211 DC211A DC240 DC241 DC241A DC265 DC270 DC271 DC271A DC271AR User Manual Family of 8 bit Digitizers ZM020010H Kev D acqiris January 2006 The information in this document is subject to change without notice and may not be construed as in any way as a commitment by Acqiris While Acqiris makes every effort to ensure the accuracy and contents of the document it assumes no responsibility for any errors that may appear All software described in the document is furnished under license The software may only be used and copied in accordance with the terms of license Instrumentation firmware is thoroughly tested and thought to be functional but it is supplied as is with no warranty for specified performance No responsibility is assumed for the use or the reliability of software firmware or any equipment that 1s not supplied by Acgiris SA or its affiliated companies Any versions of this manual which are supplied with a purchased product will be replaced at your request with the latest revision in electronic format At Acqiris we appreciate and encourage customer input If you have a suggestion related to the content of this manual or the presentation of information please contact your local Acqiris repr
34. all Acqiris driver files acqiris acqrs and acqir to some archive directory The DLL files will be installed into the bin subdirectory of the Acqiris software root and the corresponding path will be added to the PATH environment variable 2 2 2 Multiple Versions With the software installation from Acqiris Software 2 0 or above it is possible to keep multiple versions on the same system but you must specify a different root directory 1 e Install Folder If you keep the same directory Setup will overwrite your previous installation To go back to a previous version you must change the PATH environment variable and reinstall the Kernel driver E Under Windows 95 98 1 Copy the VXD file from old AcqirisSoftware root MbinNkernel to the Windows System directory 2 Change the AcqirisDxRoot environment variable to the old root 3 Reboot the computer Under Windows 2000 NT4 XP User Manual Family of 8 bit Digitizers Page 10 of 66 acqiris l Copy the SYS file from lt old_AcgirisSoftware_root gt bin kernel to the Windows System32 drivers directory 2 Change the AcqirisDxRoot AcqirisDxDir and PATH environment variables to the old root 3 Reboot the computer 2 2 3 Installation Before installing the Acqiris hardware you should complete the following steps to install the software for Windows 95 98 2000 NT4 XP N NOTE You will need administrator privileges to complete the software installation under W
35. anical support Close the PC Module in a CompactPCI crate Follow the instructions of the crate manufacturer to insert the DC Series card into a free 6U CompactPCI peripheral slot Be sure to ground yourself by touching the grounded crate and avoid touching any components on the DC Series card Be sure to tighten both front panel mounting screws to lock the module into place and insure proper grounding of the frame NOTE To ensure the best possible performance users of Acqiris CCI21 Crates with ASBus systems should respect the module placement rules to be found in the Acqiris CCI21I CompactPCI Crate User Manual PCI Bus extension module in a PC Consult the manufacturer s documentation for any special instructions Open the PC identify a free PCI slot and carefully insert the card into it Be sure to ground yourself by touching the grounded PC frame and avoid touching any components on the card Make sure that the grounding of the card s mounting bracket to the back panel rail of the computer is done correctly Close the PC Connect the module to the CompactPCI crate controller 3 Turnon the power of the crate s 1f present and then the PC and start the operating system NOTE Acqiris Digitizers are equipped with a LED If this LED is not glowing orange or red when the power is applied there is a severe problem Either the module is broken or the necessary voltages for its use are not available NOTE For proper system operation when usin
36. arns that an important point must be observed WARNING Denotes a warning which advises you of precautions to take to avoid being electrically shocked CAUTION Denotes a caution which advises you of precautions to take to avoid electrical mechanical or operational damages NOTE Denotes a note which alerts you to important information Italic text denotes a warning caution or note Bold Italic text is used to emphasize an important point in the text or a note mono text is used for sections of code programming examples and operating system commands User Manual Family of 8 bit Digitizers Page 5 of 66 acqiris Certain features are common to several different modules For increased readability we have defined the following families DC271 FAMILY DCI35 DC140 DC211 DC211A DC241 DC241A DC271 DC271A DC271 AR DP214 DP235 DP240 1 4 Disclaimer and Safety The DP Series PCI Digitizer cards have been designed to operate in a standard PCI slot found inside most personal computers The model DC Series CompactPCI PXI Digitizers have been designed to operate inside a CompactPCI PXI crate The crate provides the modules with all needed power Acqiris does not recommend operation of the DC Series modules outside of a CompactPCTI PXI crate CAUTION Do not exceed the maximum input voltage rating The maximum input voltage for 50 input impedance is 25 V The maximum input for 1 MQ input impedance is 100 V dc ac except for the DC2x1A AR m
37. as received a trigger Stop will stop the acquisition and hold the latest complete acquisition on the display Single mode is used in order to capture one event at the first valid trigger It freezes the acquisition in the digitizer s memory and on the display until the user requests another acquisition After an acquisition 1s taken in Single mode the digitizer will ignore subsequent trigger events until the Single button is pressed again or another acquisition mode is selected Pressing the single button re arms the trigger and captures one acquisition at the next valid trigger Normal mode is used to continuously acquire waveforms into memory for valid trigger events The display is updated with the new acquisitions in accordance with the Display Refresh Rate setting under the Options menu on the top line of the AcqirisLive Control window Acquisitions will happen for each valid trigger until either single or Stop is pressed If the trigger indicator at the lower left of the waveform display does not blink green the digitizer is not receiving valid triggers Check the trigger settings or select Auto mode in order to obtain a display of the waveform Auto mode will acquire and display waveforms according to the trigger settings if a valid trigger is present within a timeout interval If a valid trigger 1s not available within this interval the digitizer generates its own trigger in order to digitize and display whatever signal is at the inp
38. better than 16 samples For more details refer to the Programmer s Guide 3 4 8 Trigger Status The front panel includes a tri color LED indicator to show the status of the trigger When the LED is green it indicates the trigger is armed and waiting for a valid trigger to occur Red indicates that the trigger has occurred the acquisition is complete and the data is waiting to be readout The user can override the default functions and program the LED color in an application specific manner 3 5 External Clock and Reference For applications where the user wants to replace the internal clock of the digitizer and drive the ADC with an external source either an External Clock or an External Reference signal can be used The Clock or Reference signals can be entered into the digitizer either by the dedicated MMCX DC271 FAMILY or BNC DC240 connector or via the shared External Input connector on the front panel all other models User Manual Family of 8 bit Digitizers Page 42 of 66 acqiris In addition for the DCI35 DC140 DC211 DC211A DC241 DC241A DC271 DC271A DC271AR models the PXI Bus 10 MHz system clock signal PXI CLK10 can be used as the reference With External Clock two operating modes are possible Continuous for the case in which the clock signals are always present and Start Stop for the situation where the user needs complete control of the sampling process When using a Continuous External Clock the user must ensure that the
39. cal speed 6000 rpm maximal noise 35 dB A Nominal Voltage 5 VDC Power input 0 8 W With electronic protection against reverse polarity impedance protected against blocking and overloading Operating temperature 0 C to 70 C Life expectancy at 25 C 45000 hours Safety approvals CE VDE UL and CSA Materials Box of stainless steel and fan of fiberglass reinforced plastic PBT housing PA impeller HOW TO INSTALL REMOVE THE FAN UNIT ON A DIGITIZER 1 Remove the digitizer from the PC prior to installing or removing the fan unit 2 Unscrew the screw of the retaining clips on each side of the fan unit 3 Twist the fan s cable a few times in order for the 2 wires to stay together 4 Introduce the cable between the spacers A and B at the back of the digitizer 5 Push the fan unit into the back of the digitizer until the fan s box is in contact with the digitizer cover 6 Place the two retaining clips on the spacers A and B and screw again the two screws Insure that the fan unit is safely attached on the two spacers 7 Connect the fan s cable as shown in the figure below The position of the power connector can vary for different model of digitizers 8 To remove the fan unit first unplug its power cable and next unscrew and remove the two retaining clips Pull the fan unit away from the digitizer Connect the fan s cable Power cable Spacer A Screw Retaining clip
40. ccurs only after all segments are filled Segments can be displayed sequentially on the display or they can be overlaid on top of each other To select an overlaid display select the item Overlay Segments under the Options menu Segmented data can be archived to any storage device on the computer in a similar way to non segmented acquisitions If the acquisition needs to be stopped before all segments are filled press the Stop button User Manual Family of 8 bit Digitizers Page 53 of 66 acqiris In order to set up the sequential acquisition mode simply select more than 1 segment on the segment selection control under the Memory section of the control window and start the SI acquisition 4 2 11 Display Features Zoom and Persistence A waveform zoom feature is available under the View menu of the display window The screen image below shows the normal display and the zoom window that appears when zoom is selected The zoom scale and center position are modified using the horizontal and vertical controls shown on the zoom display window To the right side of the zoom window click on the Horizontal button then modify the zoom expansion factor by clicking the In or Out buttons The vertical blue cursor or box depending on the zoom factor shown on the main display window indicates the center point and range of the zoom The vertical box or line can be dragged right or left with the mouse in order to re position the cen
41. cgiris GeoMap Wizard E A xl Step 1 Crate count Step 2 Bus location Step 3 Crate size Step 4 Module locations How many crates do you have with activated amp cqins modules 7 Hest gt gt User Manual Family of 8 bit Digitizers Page 60 of 66 acqiris The choice of the number of crates ranges from None up to the number of bus segments that the driver has found containing Acqiris modules If you choose None and save the resulting AqGeo map file the system will behave in its natural way without any additional user provided information If you want to give the driver information on the physical position of modules you should select the appropriate number of crates If the number of crates does not correspond to your expectations you may have hardware problems unpowered broken or badly cabled crates or modules The next step 1s to associate each bus segment with a physical crate The menu to do this 1s shown below fe Acgiris GeoMap Wizard E f B xl Step 1 Lrate count Step Z Bus location Step 3 Crate size Step 4 Module locations In which crate are the modules with the red LED Select corect one Modules fram bus 4 are in crate H Modules fram bus 5 are in crate Modules from bus HB are in crate H x Previous Mest gt gt i Selecting a row will cause all of the LED s of modules in that Bus to be turned on RED This should make it easy to identify which cra
42. ch for the device Acqins D Cg DP Digitizer Windows i now ready to install the best driver for this device Click Back ta select a different driver ar click Next to continue Location of driver CIN DUAS SIN PAC OIA YO INF Cancel To proceed with the installation click Next The following window will appear User Manual Family of 8 bit Digitizers Page 25 of 68 acqiris Add New Hardware Wizard o Acqiig DCsss DP Digitizer Windows has Finished installing the software that your new hardware device requires Lancel Click Finish and the hardware installation will be complete 2 5 3 Windows 2000 Under Windows 2000 you must login with administrator privileges after the first boot following the hardware installation the Plug amp Play system must have the appropriate privileges to be able to complete your hardware installation successfully After a successful hardware installation you will be able to use your Acgqiris Digitizer s with normal privileges At the first boot following the hardware installation Windows will detect the new hardware and will install the devices automatically The following image will appear Found New Hardware Acqiris PCI Instrument Installing NOTE In some systems an application program such as AcqirisLive will not yet work correctly at this point One additional boot cycle may be needed if this is the first time that a hardware board is b
43. d scitote eres E ern LEE occae 42 3 4 5 WIndow K T o een teen ere rete eee ner bebat demas tee tere nen rinn eer sere eee etn sto coord 42 3 4 6 PETT SO Uh ak da ah an La ac MM at eae cn LE eu EM dit EI 42 3 4 7 Priccgod Fost Tri tecr Deli haem eee ene ene ee ere ne eRe mm eee ete tiep 42 3 4 8 ARBs en Fb E er oe en RO rr neo a ON MEM TN eee eee 42 35e XxExtemalClockana Ie ecre Ta oops atte cat cant sh ceed daca E E al cates abends atten ele ea atin 42 Ox NCPC altDEalTOBIc custode semtasiesct a ned a a es uev eS basi actin Rise 43 S II E E I 43 3 8 Special Front Panel Inputs and Controls DC271 FAMILY T 44 3 9 External Trigger Output DC271 FAMILY T 44 3 10 Dtequency Counter THOU escas Ite pedes etek aca auis aha a nter i estie nist 45 3 11 Electrical Environmental and Physical SpeciThcanong sss 45 3 HET FCC 611 EN E A E E AE A T T M 45 3 11 2 Envitonmental and PHystedlz uomo i mao Pme a thun irs et urne a meten UE 46 4 RUNNING THE ACQIRISLIVE APPLICATION ccsssssssssssssssscccsssssssssssssssssssssscssccsssssssssees 47 Z1 Octuds 5 tartedwith ACaoIHs Av Arasi a EAEE meses Es dus entes bri bos a i Less e dtu mee Dd 47 22 Control Panel aie Fumi OMS urena b nftemb ntes bonu ca ER Ubes see entes iustis AR entes Dd 48 4 2 1 Control Piel WOO retea eben aenea tocado eds laine Mesue 48 K D2 Displaying ETT ETTR TTT 49 42 3 Numeric aT oS 50 4 2 4 hore hast 01 8 RR LU ML C pm 50 25 Input
44. de The choice of mode is entirely determined by the preference of the user Both modes provide the same set of functional capabilities but display the settings slightly differently For example in Transient Recorder Mode the user selects the Full Scale Range of the amplifier whereas in Oscilloscope Mode the user selects the input voltage scale set in Volts Div The desired mode is selected using one of the two buttons shown at the top of the control panel The distinction between the control panels for the two operating modes can be seen in the images below In both modes it is possible to set the memory depth and the sample speed independently within the limits of the maximum available memory However the two modes differ in the following way In Oscilloscope Mode the user selects the time window time per div and the sampling rate will be adjusted to the fastest possible within the limits of the available memory The maximum available memory is programmable In Transient Recorder Mode the user selects the capture time window the sampling rate or the number of samples When selecting the capture time window the number of samples is adapted keeping the current sampling rate and number of segments up to the maximum available memory on the card When selecting the sampling rate the number of samples is adapted keeping the current capture time window and number of segments up to the maximum available memory on the card When selecting the
45. de format is limited to 200 segments The Binary file format selection provides the fastest storage performance and generates the smallest files on the hard drive Binary files can be subsequently converted to either Raw ADC values or to Amplitude values using the Data Format Conversion utility provided with AcqirisLive Selecting the Write files at end option acquires all waveforms into memory first before converting to the selected format and writing the data to disk This option allows for faster data capture times Selecting the Show waveforms allows the user to see the waveforms before writing them to disk When all parameters are selected click OK and then select Normal Auto or Single acquisition mode When the waveforms are recorded a progress bar will appear to show the status of the acquisition and of writing the data to disk The Autostore function can be aborted from the progress bar Raw ADC values are the raw 8 bit ADC levels in ASCII format The channel s gain and offset are needed in order to obtain the signal level in Volts The required information to convert the Raw ADC values to voltage is included in the header information of each Raw ADC ASCII file or in the awh file accompanying the binary files In order to convert the Raw ADC values into Volts the following formula should be used V vGain data vOffset The Amplitudes V selection stores the waveforms as voltage samples in ASCII format This dat
46. digitizers have an external trigger range of 3 V The DC271 FAMILY digitizers will trigger on signals with a peak peak amplitude gt 15 FS from DC to their bandwidth limit User Manual Family of 8 bit Digitizers Page 41 of 66 acqiris 3 4 4 Edge Trigger Slope The trigger slope defines which one of the two possible transitions will be used to initiate the trigger when it passes through the specified trigger level Positive slope indicates that the signal is transitioning from a lower voltage to a higher voltage Negative slope indicates the signal is transitioning from a higher voltage to a lower voltage 3 4 5 Window Trigger The DC271 FAMILY digitizers implement a Window trigger Two trigger level thresholds are used to define the desired range The trigger can then be chosen to occur either when the signal exits or enters the window range This mode can be thought of as the appropriate OR of two edge triggers of opposite slope 3 4 6 HF Trigger The DC271 FAMILY digitizers implement an HF trigger that allows triggers to be reliably accepted at rates above GHz In this mode triggers occur on every fourth positive edge The window trigger mode is not available 3 4 7 Pre and Post Trigger Delay To increase trigger flexibility a pre or post trigger delay can be applied to the trigger position The amount of pre trigger delay can be adjusted between 0 and 100 of the acquisition time window i e sampling interval x number
47. driver software Administrator option Make this action the system default The PCI 8570 PXI 8570 User s Manual Rev 1 00 section 2 4 contains the software installation instructions These should be executed before allowing the hardware installation process to look for the driver If you have an AdLink CD Version 2004A4 or later you can use it if not you should download the latest driver from the WEB site http www adlinktech com You can then continue with the Hardware Installation A reboot will then be necessary At this point the Stargen Fabric PCI Adapter and the Stargen Aruba Fabric to PCI Bridge should appear correctly installed under System Devices in the Device Manager NOTE If you have an AdLink CD Version 2005A3 or 2005A4 you can find 8570install exe in the folder X Driver Installation PXI Platform PXI Extension PCI PXI 8570 Wnt2kxp and the starfabl inf file in the folder X Driver Installation PXI Platform PXI Extension PCI PXI 8570 Win98 2 2 Installing the Software under Windows 2 2 1 Warnings If Setup detects a previous installation of Acqiris software on your system a warning screen will be displayed It is recommended to exit Setup and uninstall older versions The installer from software releases prior to Acqiris Software 2 0 installed the Digitizer Driver DLL files into the System directory These will be removed by Setup If you wish to keep the old installation on your system you should exit Setup and move
48. e directory containing FPGA bit files lib directory modules acqrsPCI o the device driver for Kernel 2 4 18 or RH8 modules acqrsPCI o 2 4 18 14 alternate driver for Kernel 2 4 18 or RHS modules acqrsPCI o 2 4 20 8 alternate driver for Kernel 2 4 20 or RH9 modules acqrsPCI ko 2 6 9 1 667 alternate driver for Kernel 2 6 9 or Fedora Core 3 modules acqrsPCI ko 2 6 9 1 667smp for above with SMP modules acqrsPCL 0 2 4 21 4 EL Red Hat Enterprise Linux version 3 modules acqrsPCT o 2 4 21 4 ELsmp for above with SMP modules acqrsPCI ko 2 6 8 2 686 Debian Sarge A linuxdriverpci directory Makefile to create acqrsPCI o LinuxGeneral h header file DDriIORules h header file S LinuxDriverPCI c kernel driver main source code S LinuxDriverPCI h kernel driver header file S LinuxConfigPCI c kernel driver configuration code Linux2 6driverpci directory Makefile to create acqrsPCI o LinuxGeneral h header file S DDrIORules h header file LinuxDriverPCI c kernel driver main source code User Manual Family of 8 bit Digitizers Page 33 of 68 LinuxDriverPCI h LinuxConfigPCI c usr include directory AcqirisD1Import h AcqirisD1Interface h AcgqirisDataTypes h AcqirisErrorCodes h visatype h vpptype h usr lib directory libAnDBSLib a libAqLib a usr src directory User Manual Family of 8 bit Digitizers GetStarted GetStartedc GetStartedc c GetStarted cpp GetStarted o Make
49. e is particularly suited for examining the jitter on an edge of a periodic signal as shown in the image below 1 200 my 255 ADC bite per Division DC271 per Division out g8nn 43920 439940 43960 43990 50000 50020 5 0040 5 0060 5 0080 5 0100 gt To clear the display in persistence display mode press the Clear button that appears on the main display window User Manual Family of 8 bit Digitizers Page 54 of 66 acqiris 4 3 Top Line Menu of AcgirisLive The top line menu contains functions offering r additional utility to the AcqirisLive application lal x Provisions are included for storing instrument setups Instrument Setup Store Options Help waveforms converting the format of stored data files identifying models and versions and in the Options Menu calibrating the digitizer extended control of event acquisition and controlling the display properties These possibilities are discussed in the next few sections 4 4 Setup The Setup menu allows you to store and recover instrument configurations When you store a configuration the parameters used to configure each of the channels of each module together with the timebase and trigger configurations will be saved in a file You will be asked to choose the destination directory for the file and be allowed to give it an appropriate name When you choose to recover a file you will be asked to give the name or navigate to it using the browser functionality If y
50. ee eer meer er 29 2 7 Distribution for Windows 95 98 2000 NT4 XP ccce eene nnne 30 2 9 DBD Om Or Kaen cae tis Bete eae utet edd RU peut ease aa ind ete banno 33 5 PRODUCT DESCRIPTION TT 35 l uU cul Wi E ene mesase 35 SEE uiris Mino PT 36 AT LOTEI QR s m m 36 3252 Inipedatit bans M Ente MEM LL M MM LM CM S E 36 ER Input Protec UON TTT 36 3 2 4 Mezzanine Bronb eid sies sete tus temm a tM I PAD A Ic 36 3 2 3 Bandwidthrand Rise K 36 3 2 6 Input VolldPe and OTISeLb siete testet EH ERU Det a Reuse tare Edu rS eR REP 38 SATA binnen Resolutions 38 3 2 8 DG Accuracy and Ene an iy MER ates teen ete aA tances ceed hart ean ee ss 38 32 9 Usin Probe Senee a aoe eure 38 E Data ACTUS ON sea MEL Mu M DARII CE M LEE 39 S L OILS RAE oto bore vs deese toco ette ndisse AU A tmd tec uuu dens sees M den 39 33 2 ACAS ONY T Te ieii a esi oie Mela aaa 39 3 973 Single and Sequence Acquisition Modes sss 40 3 3 4 T sana Mete 40 User Manual Family of 8 bit Digitizers Page 3 of 66 3 3 0 T nebase Re cuo ass ot auem nidi a sume aaa E LL Les ru 40 3 3 6 Combining channels co oot be vta dde Santee ean au a ME EE 41 Se ADBSBC etus tos eaten uu Sea EES Lu uM ELI Li D E Te 4 3 4 1 DS Ol SOUPE c as ie aint notte dites A Aaa E a a a 41 3 4 2 TAPS OCC OU MINS is pees See S 41 3 4 3 Tezer Eev TT 41 3 4 4 Ddocorris9ecr SIODE uec Nee
51. eing installed 2 5 4 Windows XP Under Windows XP you must login with administrator privileges after the first boot following the hardware installation the Plug amp Play system must have the appropriate privileges to be able to complete your hardware installation successfully After a successful hardware installation you will be able to use your Acqiris Digitizer s with normal privileges If you login with administrator privileges after the first boot following the hardware installation Windows will detect the new hardware and start the Found New Hardware Wizard after a few seconds NOTE Acqiris Digitizers and the drivers provided do not support the Standby mode You may want to de activate this feature if it is in use on your PC An error message will occur if the transition into Standby mode is attempted User Manual Family of 8 bit Digitizers Page 26 of 68 acqiris Found Mew Hardware Wizard Welcome to the Found New Hardware Wizard Windows will search for current and updated software by looking on your computer on the hardware installation CD or an the Windows Update Web site with your permission Can Windows connect to Windows Update to search for software CO es this time only CO T es now and every time connect a device CO No not this time Click Next to continue Back Nest gt To proceed with the installation click No not this time and then Next The following window will appear F
52. er the control of a channel parameter s can be used to set the current value to all channels of all available instruments c can be used to set the current value to all channels of the current instrument Other shortcuts are Ctrl S as a synonym for Save Setup Ctrl R as a synonym for Recall Setup Ctrl C as a synonym for Calibrate all active instruments Ctrl E functions as a toggle between Internal Clock and External Clock operation User Manual Family of 8 bit Digitizers Page 50 of 68 4 2 5 Input Voltage Scale Offset and Coupling Settings for input voltage scale offset coupling and impedance SSERZESTT mum are available in the portion of the control panel shown to the right Input Voltage Full Scale The selected channel is shown on the upper section of the display M Only this channel will be affected by changes in any settings on zi i the control panel The input voltage scale is set by one of three possible methods Coupling AC CoC Input valtage Offset 000 00V 1 Clicking on the white numeric display of the voltage scale will show a pop up list Select the desired gain setting with the mouse pointer 2 Clicking on the Decrement Increment icons will step the voltage scale up or down to the next level for each click of the mouse 3 Clicking Max Min will toggle to the least sensitive gain setting or to the most sensitive gain setting The inpu
53. er to select the trigger source click the drop down source menu in the trigger Source section of the control panel and choose the desired one Notice that for most digitizer models when external trigger is selected the controls for the trigger termination 50 Q or 1 MQ are enabled in the Coupling section Select the desired termination for the external trigger The Coupling section also contains a selection for AC or DC coupling AC coupling on the trigger sets the trigger circuit to an AC Low Frequency Reject mode Use the Level section to set the desired trigger level The relationship between coupling trigger source and trigger level was discussed in section 3 4 3 Trigger Level The DC271 FAMILY digitizers have two adjustable trigger levels associated with the range of the window trigger The trigger Delay setting positions the acquisition with respect to the trigger Pre trigger values are negative and are selectable in the range of 0 to 10 timebase The value 10 timebase 19 equivalent to the time window or capture time 100 pre trigger is achieved by setting the Delay to capture time A 100 pre trigger delay means the trigger point is at the right edge of the display and all of the data in the acquired waveform were captured just prior to the trigger event Maximum Post trigger delay settings depend on the sample interval used Post trigger delays are adjustable up to 200 Mpoints User Manual Family of 8 bit Digitize
54. es an overload protection that will automatically switch the coupling from 50 Q to 1 MQ if the signal is greater than 5 V DC This is implemented for most modules not the DC2x1A that have the 1MQ impedance possibility 3 2 4 Mezzanine Front end The front end electronics are all mounted on a removable mezzanine card In the event of accidental damage or as components fatigue over time e g relays in high duty cycle automated testing applications the mezzanine card allows for fast and efficient replacement 3 2 5 Bandwidth and Rise Time The bandwidth specification indicates the frequency at which an input signal will be attenuated by 3 dB approximately 30 loss of amplitude The bandwidth also affects the minimum rise and fall times that can be passed through the front end electronics A pulse with a very sharp edge will be observed to have a minimum rise time Tmin determined by the front end electronics In general a pulse with a given 10 90 rise time Tj0 90real Will be observed with a slower value given by Tiu qoos T where Gane ns 0 35 GHz ns BW GHz The following table indicates the bandwidth and rise time performance of the DP and DC Series digitizers For many digitizers the bandwidth can be limited with hardware bandwidth limiters as shown in the tables below For many of the older models the bandwidth at 50 mV FS BW5o is not as high as that of the other sensitivities User Manual Family of 8 bit Digitize
55. esentative or Acqiris Technical Support support acqiris com or come visit our web site at http www acqiris com Trademarks product and company names listed are trademarks or trade names of their respective companies Acqiris Headquarters Acqiris SA 18 chemin des Aulx CH 1228 Plan les Ouates Geneva Switzerland Tel 41 22 884 33 90 Fax 41 22 884 33 99 Acqiris USA Acqiris LLC 234 Cromwell Hill Rd P O Box 2203 Monroe NY 10950 1430 USA Tel 845 782 6544 Fax 845 782 4745 O Copyright January 2006 Acqiris SA AII rights reserved User Manual Family of 8 bit Digitizers Acgiris Asia Pacific Acgiris Pty Ltd Suite 7 Level 1 407 Canterbury Road P O Box 13 Surrey Hills 3127 Australia Tel 61 3 9888 4586 Fax 61 3 9849 0861 Page 2 of 68 CONTENTS 1L MOU TOE TIE BOX uicina rete e HER REPE E IUE ERE o te vU E EFE eeu Aaa DUE CrO eua TX SNR ERE Oe veo ARTINCA 5 Tel Messie tothe WSC T 5 12 Usmethis Manual ER bt ete eset epe eM M eMe LCD tent ehe set UL clad a 5 Los Conventions Usedin This Manual ie oin i telo A OA AO A e 5 L4 Drokim and Sale Vespinae db b t cepta E E ET E EE E 6 15 Wamine Reeardine Medical Use dioe ottime AE E AE tears haan seas 6 L6 3Packapip and Hdi E ea a a a a a 6 bee AN a OR T a Nor e adtuannatrbaSaiuteacins of 1 8 Warranty and Repair Return Procedure Assistance and SUDO sss sese eee eee 7 9 system RequiEefBefils 6 opp eneige cuento buteghtiinsto Emu
56. esource file of VC sample program resource h Resource file of VC sample program vxworks directory with AcqirisVxWUmode out AcqrsD1 VxWorks driver VxWorksDriverPCl out AcqrsD1 VxWorks Low Level driver LabVIEWhelp directory with the help file needed for a LabVIEW program AQDRV4 HLP LabVIEW Instr lib AqDx directory with the files needed for the chosen LabVIEW version acstat mnu applic mnu AqDx llb AqDx obs llb AqDx u b AqRT Ilb AqRT u llb config mnu data mnu dir mnu User Manual Family of 8 bit Digitizers Page 32 of 66 acqiris util mnu Windows directory Windows or WINNT Acqiris Software Setup Log txt a readable record of installation activity Windows system directory Windows system or WINNT system32 acqirv00 vxd Win9x drivers Acqir400 sys NT4 drivers Acqir500 sys Win2000 WinXP msvcp60 dll Microsoft VC run time Msvert dll Microsoft VC run time Windows Mnf directory WINNTWnf acqirv04 inf Win9x 2000 2 8 Distribution for Linux AcgirisLinux directory drv install install script creates system load script acqstartstop hidden file used by the install script demo directory AcqirisDemo script to start the AcqirisDemo application AcqirisDemo bin AcqirisDemo application based on the Qt GUI libqt mt so 3 Qt 3 3 2 GUI library AgqDrv4 ini to indicate where FPGA bit files can be found Firmwar
57. f calibration on the digitizers calibrating the gain offset trigger level and the timing Performing a calibration compensates for any drift in these properties typically due to component temperature variations Calibrate current combine configuration to perform a calibration only at the current configuration in each instrument Calibrate External Clock Timing to do a calibration of the internal TDC in the Continuous External Clock mode User Manual Family of 8 bit Digitizers Page 56 of 66 acqiris 4 7 Combine channels The Combine Channels function in the Options menu gives the DC135 DC140 DC241 DC241A DC271 DC271A DC271 AR DP235 DP240 user the control of how many converters will be used for each channel This allows the memory size and the sampling rate to be increased in situations where not all of the input channels need to be acquired Normally digitizer modules work with one converter channel If two or more converters channel are desired the identities of the channels to be used have to be chosen with the Active Channel control 4 8 External 10 MHz Reference and External Clock Either one of the External 10 MHz Reference or External Clock options can be selected in the Options Menu The external input threshold option available in the options menu must also be set appropriately The 10 MHz Reference can be activated at the I O B output The External Clock function is available in AcqirisLive only when using the
58. file acqiris kernel driver header file kernel driver configuration code Header file for C C Acqiris Device Driver Interface Definitions API Data Structure Header file for C C Acqiris Error Code definitions VISA types Linux Acqiris library compiled with gcc 3 2 Linux Acqiris base library Linux sample program Linux sample program Linux sample program source Linux sample program source Linux sample program object makefile to create the application Page 34 of 66 acqiris 5 Product Description 3 1 Overview Signal bit Input l Ext memories Spi DEMUX NE 128K Amplifier 9 Acq Mem n 50 1M Ohms Ohms TIMEBASE me trigger Input Trigger TRIGGER signal circuit Amplifier Thr DAC 50 1M Ohms Ohms Cal v Card PLX s Controler PCI Interface PCI Bus Acqiris Digitizers are available in two popular industry standards The DP series digitizers are PCI modules that plug directly into a vacant PCI slot in a PC The PCI Bus is a well defined industry standard with a 32 bit bus operating at 33 MHz The DC series products are CompactPCT PXI compliant and require an appropriate CompactPCI crate The digitizers are all fully programmable over the PCI bus and deliver oscilloscope like performance Data captured by the di
59. g the IC200 IC414 or other PCI extension interface from Acgiris to connect a CCIOX crate to a remote PC the crate must be powered on before the PC in order for the PC BIOS to recognize the presence of the CompactPCI crate 4 For Windows NT 98 95 ONLY Go into the BIOS Setup menu Under the Advanced section or the Boot section you may find a selection named Plug amp Play OS Check that its value is No If it is not you should change it to this value and save the settings NOTE For proper system operation under Windows NT 98 95 ONLY the Acqiris Driver expects that the BIOS has already configured any modules present Plug amp Play OS Yes inhibits this activity and can result in the Acqiris hardware not being recognized 5 Devices that were installed using a previous version of Acqiris Software the instruments in these logical positions will still appear as Unknown Devices This can be changed to the new Acqiris type category with the Grey Diamond icon by Uninstalling the device and then Installing again Instructions on this procedure can be found in the ReadMe txt file in the manuals folder of your Acqiris Software installation 2 5 After Restarting 2 5 1 Windows 95 Under Windows95 the first time the system is started the Plug amp Play system will automatically detect the Acqiris hardware and briefly display a New Hardware Found dialog box prior to automatically installing the new hardware 2 5 2 Windows 98 Under Windows98
60. gitizers can be transferred to a host processor either in the PC in the crate or interfaced to the crate over the PCI bus at speeds up to 100 Mbytes s DCI1XX series digitizers occupy a single slot of a 3U CompactPCI crate and they comply with the 3U Compact PCI standard PXI compliant DC2XX series digitizers occupy a single slot of a 6U CompactPCI crate and they comply with the 6U CompactPCI standard PXI compliant Acqiris digitizers are designed to provide superior measurement precision and accuracy Key acquisition specifications such as DC accuracy integral and differential non linearity have been optimized to deliver maximum measurement fidelity Careful circuit layout custom IC s and special packaging techniques have all been employed to reduce overall system noise The use of custom IC s also dramatically reduces the total number of discrete components required This has tremendous benefits on reliability and also allows the modules to use a minimal amount of power 15 W typical for a single channel 1 GS s card For complete technical specifications concerning your particular digitizer please refer to the product s Specifications amp Characteristics In addition Acqiris maintains up to date versions of all product data sheets on our web site www acqiris com The data sheets are available in pdf format and are best viewed using Adobe Acrobat software If you have trouble accessing our web site or viewing the data sheets please
61. he digitizer HOW TO INSTALL REMOVE THE DIGITIZER IN A PCI SLOT OF APC 1 Install the fan on the digitizer as described above 2 Release the three screws R from the adjustable retainer and move the retainer against the fans 3 Introduce the digitizer into the PCI slot and tighten the front panel screw 4 Push the retainer into the PCI slot guide and tighten the three screws R The digitizer is now installed 5 To remove the digitizer it is necessary to first release the three screws R and pull back the adjustable retainer Spacer A Screws R ez Power connector on the internal R edge of the digitizer Power cable Spacer B Adjustable retainer User Manual Family of 8 bit Digitizers Page 68 of 68
62. igger coupling is used to select the coupling mode applied to the input of the trigger circuitry Modes available include AC LF Reject and DC The AC LF Reject mode couples signals capacitively and removes the input signal s DC component and signals below 50 KHz 50 Hz for DC271 FAMILY digitizers DC mode allows all signal components to be passed through to the trigger circuit The DC271 FAMILY digitizers have an HF Reject mode that removes signal components above 50 KHz 3 4 3 Trigger Level The trigger level specifies the voltage at which the selected trigger source will produce a valid trigger The trigger level is defined as a set voltage Using the internal trigger the level is set with respect to the midpoint voltage V Offset voltage of the digitizer s vertical scale Internal trigger level settings expressed in must be within V 0 6 FS 0 5 FS for DC271 FAMILY digitizers where FS is the channel Full Scale All trigger circuits have sensitivity levels that must be exceeded in order for reliable triggering to occur For most digitizers the AC coupled mode is implemented with an auto level trigger Only the DC271 FAMILY digitizers allow trigger levels to be selected in connection with the AC coupling choices The DC271 FAMILY digitizers allow the user to choose the external trigger Full Scale from the set of values 0 5 1 0 2 0 or 5 0 V The external trigger level can then be set to values in the range 0 5 FS All other
63. igitizers XB101 ASBus left termination bridge XB101 l J L 1 to 4 ASBus bridges XB100 7 2 ASBus right termination bridge XB102 User Manual Family of 8 bit Digitizers Page 63 of 68 acqiris y Appendix B XA001 Battery Backup for CompactPCI Digitizers Specification and Assembly Instructions SPECIFICATIONS Please refer to the user manual for more detailed information on the use of the battery backup Time to charge the battery 2 5 h digitizer powered Backup duration time without long memory option gt 120 h with long memory option gt 12 h Lifetime 7596 of battery capacity after 500 cycles CompactPCI digitizer XA001 Battery Backup ATTENTION The CompactPCI digitizer must always been powered off before either introducing or removing the battery backup and care must be taken in order to avoid electrostatic discharges The following steps are necessary to install the battery backup XA001 into a CompactPCI digitizer 1 Position the battery backup between the guides A and B insuring that the orientation matches the figure below 2 Lift the two strips C and D in order to introduce the circuit board of the battery into the guides A and B 3 Push the battery in the direction of the card until it hits the stop blocks and ensure that the strips C and D are correctly and securely attached Proceed in the reverse order to remove the battery V borrors E asnan D
64. indows 2000 NT4 XP 1 Insert the Acqiris Software CD into the CD ROM drive of your computer If the Autorun program does not start automatically Autoplay disabled you can start it manually or navigate to the AcgirisSoftware Windows folder in order to display the files included 2 Choose Install AcqirisSoftware for Windows 95 98 2000 NT4 XP or run Setup exe from the AcgirisSoftware Windows folder After several seconds for initialization the following screen will appear jie Acqiris Software Setup Welcome Welcome to the Acqins Software setup program It iz strongly recommended that you exit all Windows programs before running Setup Click Cancel to quit Setup and close any programs You have running WARMING This program i protected by copyright law and International treaties Unauthorized reproduction or distribution af this program may result is severe civil and criminal penalties and Will be prosecuted to the maximum extent possible under law un qi L m Click Hest to continue with the setup wea User Manual Family of 8 bit Digitizers Page 11 of 68 3 To proceed with the installation click Next The following screen will be shown jie Acqiris Software Setup User Information Please Fill in your user information and click Nest to continue TOU must complete these fields in order to continue with the setup Hame Your name Company You company 4 Please enter your
65. irmware is in usr local AcqirisLinux Firmware and that AqDrv4 ini is in usr local AcqirisLinux demo then you must edit AqDrv4 ini so that it contains the line fpgaPath usr local AcqirisLinux Firmware Then if your shell is csh or tcsh modify the etc csh login file to contain the line setenv AcqirisDxDir usr local AcqirisLinux demo or if your shell is bash ksh zsh or sh modify the etc profile file to contain the lines AcqirisDxDir usr local AcqirisLinux demo export AcqirisDxDir 2 4 Installing the Hardware 1 Turn off the power of the PC and the crate in the case of a CompactPCI module CAUTION For PCI modules the PC may have to be unplugged to ensure that the PCI bus has no power available However CompactPCI crates can be left plugged in since this ensures proper grounding CAUTION Touch the antistatic package to a grounded object before removing the card from the package Electrostatic discharge can damage the card 2 Module in a PC open the PC identify a free PCI slot and carefully insert the DP Series card into it Be sure to ground yourself by touching the grounded PC frame and avoid touching any components on the DP Series card Make sure that the grounding of the card s mounting bracket User Manual Family of 8 bit Digitizers Page 22 of 66 gt acqiris to the back panel rail of the computer is done correctly If present make sure that the fan s adjustable retainer is correctly positioned and tightened for mech
66. le configuration of the instrument its disadvantage 1s the time taken If a more selective calibration is done it will allow the generation of good data in the current acquisition state This calibration will remain useable whenever that acquisition state is used again for as long as the temperature of the instrument does not change significantly A fast calibration of a channel in a configuration can be done in around a second Many applications can save time by only performing calibration for the configurations that will actually be used 3 7 ASBus The DC Series digitizers may be used in applications that require many data acquisition channels In such cases it 1s possible to use more than one digitizer in a standard CompactPCI PXI crate Each DC Series digitizer except the DC135 and DC140 models includes ASBus a proprietary high bandwidth auto synchronous bus system that allows multiple digitizers to work together synchronously The ASBus distributes both the clock and trigger signals along a plug in front panel bus between all the digitizers that participate in the system It allows any digitizer to act as the trigger source and any other digitizer to act as the clock source acquisition master enabling all the digitizers to be clocked at the same time Synchronizing the clock signals between the devices improves the accuracy of cross channel measurements and is essential for accurate time correlation between signals on different channels
67. lect All Desired Platforms Select one ar mare af the below and click N evt ta continue Please select one or more of the platforms that vou may want ta use below IZ Windows Program Development LabVIEW AT Phar Lap ETS T Wind River Ve orks All platforms User Manual Family of 8 bit Digitizers Page 13 of 68 acqiris 8 The screen below asks for the desired installation type After having made your choice Click Next to continue jie Acqiris Software Setup Select Install Type Select an installation type and click Nest to continue Complete Instrument Driver Applications and development support for all supported Windows environments C Instrument Driver and Applications only Instrument Driver and A amp cqinsLive No development support will be installed C Custom Lets you decide which components you want to install 9 If you chose the Custom installation the following screen will let you select each package individually Note that the space indicated for LabVIEW Firmware and UserManual packages 1s incorrect The correct values are 10 MB 23 MB and 27 MB respectively jie Acqiris Software Setup Select Packages Select the packages that wou want ta install and click Mest Select each package that you want to install B Acoins Digitizer Driver 2 0 MB Iw AcqinsLive 13 8 MB WIM Run Time Engine 3 5 MB n MAP sO Demo 12 4 MB Iv Firmware 1 K Development Supp
68. level driver Acqir400 sys WinNT4 low level driver Acqir500 sys Win2000 low level driver Aq _RT inf LabVIEW RT driver CVI directory with the files needed for a LabWindows CVI program GetStarted c C source code of CVI sample program GetStarted h Header associated with the User Interface file of CVI sample program GetStarted prj LabWindows CVI project file of CVI sample program GetStarted uir CVI User Interface file of CVI sample program User Manual Family of 8 bit Digitizers Page 30 of 66 GetStartedETS cpp GetStartedETS dsp GetStartedETS dsw GetStartedETS Ink GetStartedETS rc GetStartedETS vsb resource h RTOS ini acqiris ETS directory with the files need for a Phar Lap ETS sample program C source code of ETS sample program VisualC 6 0 project file of ETS sample program VisualC 6 0 workspace file of ETS sample program only after 1 run ETS application linker file VisualC 6 0 resource file of ETS sample program VisualSystemBuilderProject file of ETS sample program Header associated with the resources for the ETS sample program ETS Configuration file Firmware directory containing FPGA bit files for AC210 AC240 AP100 AP101 AP200 AP201 AP235 AP240 DP306 DP308 DP310 DC436 DC438 DC440 SC210 and SC240 Include directory with AcqirisD1Import h AcqirisD1Interface h AcqirisDataTypes h AcqirisErrorCodes h AcqrsD1Interface bas AcqrsD1Interface vb visatype h vpptype h AqDr
69. mmunicate with us using eMail Our standard form will require your name company phone number and address the model and serial numbers of the unit to be repaired and a brief description of the problem If a unit returned under guarantee is found to be working normally and this procedure was not followed we reserve the right to charge you for the work done As well as providing you with an RAN Acqiris Support Centers can assist you with any questions concerning the installation operation or service of your equipment For your nearest customer support center contact Acqiris at 1 877 ACQIRIS in the USA 41 22 884 33 90 in Europe or 61 3 9888 4586 in the Asia Pacific region 1 9 System Requirements In order to obtain reasonable performance from your digitizer Acqiris products need the following minimum PC System Requirements Processor 150 MHz Pentium higher recommended Memory 64 Mbytes RAM The previous number is a very rough estimate Assuming that you are using AcqirisLive or an application of your own that operates on the acquired data it seems reasonable to ask for 10 times the total acquisition memory that you will be using at the same time in the application Performance is likely to be degraded if less memory is available Display resolution At least 800 x 600 pixels and 256 colors for use of AcqirisLive or AcqirisDemo Operating System Microsoft Windows 95 98 2000 NT4 XP Phar Lap Real time ETS 12 0 Kernel Wind River VxWorks
70. multi thread process After starting an acquisition a new thread is created to wait for the hardware interrupt indicating that the acquisition completed This thread is put to sleep and wakes up upon reception of the interrupt from the instrument or after a 2 seconds timeout Please note that switching the DMA data transfer mode off precludes the use of acquisition interrupts The i switch will therefore be ignored when n is used Transient recorder mode The application will start in the transient recorder mode as opposed to the oscilloscope mode Simulation Mode Simulation mode allows you to run AcqirisLive without having any digitizer installed in the PC Temperature Update The internally measured temperature of the currently selected module is normally displayed Using this switch turns this feature off Acquisition State This switch turns on the display of the current acquisition state Stopped Ready Started Reading Data ready This is helpful when running with time consuming settings e g many segments overlaid many channels large records etc but will slow down the overall performance Multi instruments By default AcqirisLive tries to detect instruments connected through ASBus and will initialize any connected digitizers as a multi instrument This behavior can be inhibited by the x switch in which case any ASBus connector will be ignored User Manual Family of 8 bit Digitizers Page 59 of 66 gt gt
71. nectors can be used for an Enable trigger input or the following output signals 10 MHz reference clock Acquisition skipping to next segment Acquisition is active Trigger is armed 3 9 External Trigger Output DC271 FAMILY When the digitizer is ready to be triggered and a valid trigger signal occurs a trigger output is generated for external use It is always available on the Front Panel Trigger Out MMCX connector The pulse ends when the data acquisition for the trigger in question is complete N NOTE The External Trigger Output functionality is implemented in the hardware No Trigger Out signal occurs for software generated triggers such as those of the AUTO mode of AcqirisLive or through the use of the function AcqrsD1_forceTrigger However AcqrsDI forceTriggerEx does generate the signal Trigger Output Block diagram Signal 1 6V swing Ov centered 90 Ohm Trigger Out The output swing is 1 6 V c 0 8 V when unloaded and 0 8 Offset 2 5 V V when terminated on 50 Q The rise and fall times are 2 5 ns typical The offset can be adjusted by software control in the range 2 5 V 42 5 V unloaded or 1 25 V 1 25 V into 50 Q The GND maximum output current capability is 15 mA As the output is retro terminated it is possible to drive a 50 Q line unterminated HiZ without loss of performance Trigger For a TTL compatible signal set the offset to 1 0 V and the Out swing at destination will be 0 2 to 1 8 V Wi
72. no special software installation Windows users should have the hardware installed as noted above This software installation should be done before any Acqiris modules are placed in the CompactPCI crates This may mean that you have to remove the module from the crate as delivered The crate should be turned on first followed by the PC If the cabling and start up sequence is done correctly there will be no LED illuminated on the PCT unit connected pair and the LED s of the PXI connected pair will be lit For Windows XP installation Select the Control Panel under Settings in the Start menu Then if you are using the Category View select Printers and Other Hardware After this for both Category and Classic views go to System and then display the Hardware tab to get access to the Driver Signing menu Since neither the AdLink nor the Acqiris driver has been submitted for Windows Logo testing you must select either the Ignore or Warn action The resulting menu looks as shown User Manual Family of 8 bit Digitizers Page 9 of 66 acqiris Driver 5igning ptions During hardware installation Windows might detect software that has not passed Windows Lago testing to verify its compatibility with Windows Tell me why this testing is important 1 What action da you want Windows to take Ignore Install the software anyway and don t ask For my approval O Warn Prompt me each time to choose an action CO Block Never install unsigned
73. nue jie Acqiris Software Setup Enable C VI Run Time Engine Loading Option Check your preference below and click Nest to continue Acqinslive needs the CI 7 0 Run Time Engine CYT ATE is installed on this machine IF IE Is an older version you should install the 7 0 version in the AcqinsLive application directory In any case your current CYT ATE installation will not be altered Ie Install Labindows Cvl 7 0 Run Time Engine lt Back Cancel 15 Depending on the install type you may be asked which LabVIEW version format you want for the LabVIEW files Select the appropriate format and click Next to continue User Manual Family of 8 bit Digitizers Page 16 of 68 jie Acqiris Software Setup Select an Option Please select an option below and click Next to continue IF uou wish to install any of the Lab EWW divers please select a LabVIEW version format availability see below LabVIEW format eo oral 6 1 C ci C NO Labview 16 A summary will be shown to allow you to check what you have asked for jie Acqiris Software Setup Installation Summary The following files will be installed Please review and click Nest to continue Diver gt C Program Filess amp cegirissbin C Program Filesss amp caqiisslib Windows Device Driver LabWindows CVI Driver MATLAB Data Acquisition Toolbox Adaptor For amp cqiris Digitizers MATLAB MEX interface LabViEW Driver gt
74. number of samples the capture time window is adapted keeping the current sampling rate and number of segments User Manual Family of 8 bit Digitizers Page 48 of 68 Oscilloscope Mode Instrument Control aof xl Instrument Setup Store Options Help E L4 1715 crate 3 pos 2 DE27T Leni m Input Voltage Scale Coupling Bs BE wo Input Voltage Offset Impedance Sl 0 0000 0 00 V 502 IMQ Level 1 EN rA 0000 0 00 V e Delay Slope Slope Y 0 00 s LAR Timebase a M Memory MAX 50000 50 0 K samples di 1 00 segments may Sampling Interval Rate l 1 0000 ns 1 0000 GS s Acquisition STOPPED OAcg s AUTO NORMAL SINGLE STOP Transient Recorder Mode Instrument Control Sel xl Instrument Setup Store Options Help ii 3 17157 crate 3 pos 2 Finder DC271 Ch1 Adv Input Voltage Full Scale Coupling 8 Bi AC CDC Input Voltage Offset Impedance 0000 ooy Gon iw Trigger Edge class Source DC271 Ch1 Level1 Ww 0 00 V Delay ee 0 00 s m Time Window ER 50 0 ps El Sampling S ined Rate CUm Fd 1ns H 1 GS s E Memory ii 5000 50 0 K samples 4 1 00 segments ER Acquisition ALTO NORMAL SINGLE stor Coupling acqiris 4 2 2 Displaying Multiple Traces If multi channel modules or several single channel modules are installed on the PCI bus multiple waveform displays one from each installed channel are overlaid on the di
75. odels where it is 23300 V dc ac 1 5 Warning Regarding Medical Use The Digitizer cards are not designed with components and testing procedures that would ensure a level of reliability suitable for use in treatment and diagnosis of humans Applications of these cards involving medical or clinical treatment can create a potential for accidental injury caused by product failure or by errors on the part of the user These cards are not intended to be a substitute for any form of established process or equipment used to monitor or safeguard human health and safety in medical treatment WARNING The modules discussed in this manual have not been designed for making direct measurements on the human body Users who connect an Acqiris module to a human body do so at their own risk 1 6 Packaging and Handling Your Digitizer is shipped with the following components e A compact disc that includes o 7 product user manuals in electronic form Family of 8 bit Digitizers Family of 10 bit Digitizers Family of 12 bit Digitizers Family of Averagers Family of Analyzers CC10X Family of CompactPCI Crates and CC121 CompactPCI Crate o Programmer s Guide and 1 Programmer s Reference Manual o device drivers with sample software for different operating systems environments and languages o the AcgirisLive application a demonstration program for our digitizer and averager products o the AP SSRDemo application a demonstration program for the Ac
76. of samples whereas the post trigger delay can be adjusted between 0 and 200 million samples Pre or post trigger delays are just different aspects of the same trigger positioning parameter e The condition of 100 pre trigger indicates that all data points are acquired prior to the trigger i e the trigger point is at the end of the acquired waveform e The condition of 0 pre trigger which is identical to a post trigger of 0 indicates that all data points are acquired immediately after the trigger i e the trigger point is at the beginning of the acquired waveform e The condition of a non zero post trigger delay indicates that the data points are acquired after the trigger occurs at a time that corresponds to the post trigger delay i e the trigger point is before the acquired waveform The digitizer hardware accepts pre and post trigger adjustments in increments of 16 samples By definition post trigger settings are a positive number and pre trigger settings are a negative number Thus it is only natural that the software drivers provided by Acqiris treat pre and post trigger delays as a single parameter in seconds that can vary between nbrSamples samplingInterval 100 pre trigger and maxPostTrigSamples samplingInterval max post trigger Since the Acqiris software drivers provide very accurate trigger position information upon waveform readout the accepted resolution of the user requested pre post trigger delay 1s much
77. onnect the fan s cable Power cable Spacer B User Manual Family of 8 bit Digitizers Page 67 of 68 acqiris 11 Appendix F XP103 Fan Unit for the DP Family of Modules Specification and Assembly Instructions SPECIFICATIONS Airflow 16 m3 h typical speed 6500 rpm maximal noise 30 dB A Nominal Voltage 5 VDC Power input 2 1 W With electronic protection against reverse polarity impedance protected against blocking and overloading Operating temperature 0 C to 70 C Life expectancy at 25 C 50000 hours Safety approvals CE VDE UL and CSA Materials Box of stainless steel aluminium and fan of fiberglass reinforced plastic PBT housing PA impeller HOW TO INSTALL REMOVE THE FAN ON A DIGITIZER 1 Remove the digitizer from the PC prior to installing or removing the fan unit 2 Twist the fan s cable a few times in order for the 2 wires to stay together 3 Introduce the cable between the spacers A and B at the back of the digitizer 4 Push the fan unit into the back of the digitizer so that the two springs lock into place 5 Insure that the two springs are safely attached behind the two spacers and that the fan s box is in contact with the digitizer cover 6 Connect the fan s cable The position of the power connector can vary between different digitizer models 7 To remove the fan unit first unplug its power cable and then press on both fan springs and pull it away from t
78. ors are transparent and therefore their channels are turned off and not displayed User Manual Family of 8 bit Digitizers Page 49 of 68 Instrument Control Ioj x Instrument Setup Store Options Help DELCA Input Voltage Scale Coupling Impedance EI mo Ady Input Voltage Offset 172 0 0000 1 00 VV Trigger Edge class Source DC271 Ch1 Level 1072 0 000 0 00 Y Coupling E LAN Timebase M n B Memory BULU K samples 1 00 segments max Sampling Delay UR 0 00E 0 0 00 s MA 50000 _ Interval Hate 1 0000 ns 1 0000 GS s Acquisition STOPPED AUTO NORMAL SINGLE STOP a 10 59 10 Ready 10 59 23 Starting calibration 10 59 50 DC271 recalibrated r Digits that are below the resolution or granularity cannot be modified A message is displayed in the numeric setting control window when the pointer is positioned over a digit that 1s below the allowed granularity and cannot be changed E 17157 crate 3 pos 2 acqiris As an alternative to controlling the channels to be displayed from the control panel you can also control them by selecting the desired channels from the list of channel gains shown at the right hand side of the display window Pressing the Finder button at the top of the control panel will identify the module associated with the current channel When the finder button is depressed
79. ort E33 K The m riimum necessary to run an application using Acqins Digitizers 10 If MATLAB is installed on your machine you will be asked to point the installer to the MATLAB root directory You should do this if you want the installer to modify the standard startup m file to incorporate the Acqiris adaptor User Manual Family of 8 bit Digitizers Page 14 of 66 11 Installation Folder acqiris Now that the elements of the installation have all been decided you will be prompted for the installation folder This will be the root directory of the Acqiris software installation If User Manuals 27 MB and Firmware 23 MB are loaded more space than indicated here will be required on the drive For the case of a Tornado 2 2 installation the folder name should not contain any spaces jie Acqiris Software Setup Select the installation folder below and click Next to continue Setup will install the software under dee root directory listed in the box below Any existing files will be overwritten To install to a different directory either type in the new path or click Browse to select another directory Install files to this location CPrearam Filezs Aeris Browse Space required on drive 21 8MB Space available on selected drive 3383 MB 12 Furthermore you should give a name to the shortcut folder This is the menu entry under Start gt im Acqiris Software Setup Shortcut Folder Programs where
80. ou are using many modules the settings in the configuration file will be associated preferentially with the digitizer that has that serial number or then with the digitizer in the same location Only the parameters of the modules are stored in the configuration file This means that parameters of the AcqirisLive program such as channel activation and display mode choices are not included 4 5 Store Autostore and Conversion of Waveforms The store menu gives you two mechanisms to store waveforms 1 The Store Waveform option allows you to store the last acquired waveform for the current channel To store the last acquired waveform for each of the active channels you must sequentially select each one to make it the current channel and use the Store Waveform menu command The title of the Store Waveform dialog indicates the name of the channel that will be stored The data is stored in ASCII format as Raw ADC values or Amplitudes in Volts 2 The Autostore option allows you to store AutoStore Settings x consecutively acquired waveforms from all of the active channels into files Destination folder Configuration of Autostore is achieved C cgirisLive Data by selecting the Autostore item under the Store menu Autostore brings up the umber of waveforms to store _ d 100 dialog box shown here Three formats are EEEESEEEEREERREERERRRRRDS available for stored waveforms Binary Mas total samples memory MB afso Raw ADC values and Ampli
81. ound Mew Hardware Wizard This wizard helps you install software Far amp cqins P Instrument L TP your hardware came with an installation CD ac or floppy disk insert it now What da you want the wizard to do Install the software automatically Recommended C Install from a list or specific location Advanced Click Nest to continue lt Back To proceed with the installation click Next You should then see User Manual Family of 8 bit Digitizers Page 27 of 68 Please wait while the wizard installs the software w Aegis PCI Instrument s 5 elting system restare point and backing up old files in Case your system needs to be restored in the future M R Sancel and then Found New Hardware Wizard Completing the Found New Hardware Wizard The wizard has Finished installing the software far Y Acgins PEI Instrument Chick Finish to close the wizard Sancel NOTE In some systems an application program such as AcqirisLive will not yet work correctly at this point One additional boot cycle may be needed if this is the first time that a hardware board is being installed User Manual Family of 8 bit Digitizers Page 26 of 66 acqiris 2 5 5 Windows NT 4 0 Under Windows NT 4 0 the operating system does not automatically detect new hardware However the Acgiris device drivers are configured to automatically search for all Acqi
82. owever it 1s possible to run each digitizer at its maximum available sampling rate performance in the following way e Select the Scope mode e Inthe channels list select a channel from the fastest digitizer that will make that digitizer the current digitizer e Make sure the maximum number of samples MAX samples in Memory panel is large enough e Select the desired time per division setting timebase panel the fastest sampling rate for the current digitizer compatible with the maximum number of samples will be selected and applied to all digitizers in the system Any digitizer not capable to satisfy that sampling rate will run at its closest setting Finally note that the sampling rate menu visible in Transient Recorder mode contains the sampling rate capability of all digitizers currently in use You must turn off the channels of slower digitizers in order to view the highest sampling rates of the faster digitizers Note versions of AcqirisLive prior to 2 0 had in the sampling rate list the capability of the first digitizer found on the system its channels appear first in the channel list 4 2 10 Segmented Memory Segmented memory enables the sequential acquisition mode This feature is particularly useful when capturing impulse response type waveforms in a variety of applications Segmented memory is available in all acquisition modes However it is generally used in either Normal or Single mode Waveform display o
83. puts 3 11 3 11 1 Electrical Electrical Environmental and Physical Specifications PCI Max Power Current Requirements A Rev Consumption W with Memory option Model DP105 os 5 o5 55 DP106 13 5 1 3 1 6 DP111 DP210 DP211 DP212 0 75 pou 2 s o 2 2 6 DP235 DC110 DC135 DC140 DC211 0 46 0 46 DC240 DC241A DC265 DC270 DC271 NA NA Na NA NA A NA 1 1 1 9 1 1 1 9 1 1 1 9 0 4 0 9 1 1 1 5 1 4 2 2 NENNEN alal a Taie E z1 o s n s 29 m 22 4 so i1 27 3045 00 pou o as 1 29 1969 na pou o s 1 29 1969 n 22 e so i1 27 soas oos 3 0 4 5 3 0 4 5 2 3 5 3 0 4 5 3 0 4 5 1 9 3 5 1 9 3 5 3 0 4 5 3 0 4 5 a N oy Tov ay a LOL pos Dia a eit aa ae 1 lw Ee 1 4 2 0 0 03 0 03 pou 9 R seam NA oo 1 4 2 0 pou 9 R seam NA oo 1 4 2 0 peza 22 2 25 os 15 ay 0 03 0 03 o2 s x os uw mas oo pea 22 274 2 o9 7 0 03 0 03 NA 1 i m ez n 09 na fj n os Le uas ew 0 04 0 04 0 05 0 05 NA 0 05 0 05 NA NA 0 05 0 05 penap 22 2 s iz 27 3045 oos All Acqiris Digitizers use the PCI Bus at 33 MHz The CompactPCI modules are compatible for either V VO 3 3 Vor5 V User Manual Family of 8 bit Digitizers 3 0 4 5 0 05
84. qiris AP235 AP240 Analyzers o the APx01Demo application a demonstration program for the Acqiris AP101 AP201 Analyzers o product data sheets o full installation procedures for use with Microsoft Windows National Instruments LabVIEW RT Phar Lap ETS Wind River VxWorks and Linux software e A declaration of conformity e Optional documentation such as a model dependent document giving Specifications amp Characteristics a Calibration Certificate or a Performance Verification After carefully unpacking all items inspect each to ensure there are no signs of visible damage Also check that all the components received match those listed on the enclosed packing list Acqiris cannot accept responsibility for missing items unless we are notified promptly of any discrepancies If any items are found to be missing or are received in a damaged condition please contact the Customer Support User Manual Family of 8 bit Digitizers Page 6 of 68 acqiris Center or your local supplier immediately Retain the box and packing materials for possible inspection and or reshipment 1 7 Warranty All Acqiris Digitizer products are warranted to operate within specification assuming normal operation for a period of three years from the date of shipment It is recommended that yearly calibration be made in order to verify product performance All repairs replacement and spare parts are warranted for a period of 3 months A 5 year repair warranty is a
85. r Manual Family of 8 bit Digitizers Page 37 of 66 acqiris Bandwidth Bandwidth Minimum BW Limiter Maximum Other into 50 Capacitance Rise Time selections Offset particularities into 1 MO DC271A 950 MHz 300 MHz 0 35 ns 20 200 700 MHz 5 V 50 DC271 FAMILY 1 GHz typical 50Q see remark below 20 V 0 5 V Max FS 50V typical 14 pF 1 2 ns FS amp IMQ 1 MQ typical 200V 25V The AR has only 2 1 MQ FS amp 1IMQ channels DC271AR For 1 MQ coupling in the DC2x1A AR the 700 MHz Bandwidth Limiter cannot be used Furthermore for FS gain gt SV the 200 MHz Bandwidth Limiter is always active 3 2 6 Input Voltage and Offset The input channel provides a fully programmable amplifier with variable input voltage and offset Full Scale FS input voltages are selectable from 50 mV to 5 V except as shown above in a 1 2 5 sequence Care should be taken to select an input voltage range that will allow the signal to be recorded using as much dynamic range of the digitizer as possible The Variable Offset is programmable in the range of 2 V when using an FS Input Voltage setting of 500 mV or below increasing to Maximum Offset for FS settings above 500 mV The raw 8 bit ADC data values are in the range 128 127 with the first and last values reserved for underflow and overflow respectively The midpoint value 0 of the range corresponds to the negative of the offset voltage Thus the Full Scale Range FSR goes from
86. random Safety Complies with EN61010 1 EMC Immunity Complies with EN61326 1 Industrial Environment EMC Emissions Complies with EN61326 1 Class A for radiated emissions Required Airflow 2 m s in situ User Manual Family of 8 bit Digitizers Page 46 of 66 acqiris 4 Running the AcqirisLive Application AcdqirisLive is an application to control and demonstrate the capabilities of Acqiris Digitizers on a single machine AcqirisMAQS is a new software application offering many interesting possibilities for the control of acquisition systems in a single or multi machine environment Ask your salesman or Acqiris for more information 4 1 Getting Started with AcqirisLive Once the software and hardware installation described in Section 2 of this manual is complete you will find AcqirisLive in the start menu of your computer Start AcqirisLive from the menu An initial AcqirisLive load screen will appear followed by a panel of controls and a waveform display window During startup AcqirisLive searches for all Acqiris Digitizers on the PCI bus If no digitizers are found on the PCI bus AcqirisLive will display an error message indicating that no digitizers were found and the program will continue in simulation mode If this is not wanted turn off the computer install and turn ON the hardware on the PCI bus and then restart the computer AcqirisLive is intended to verify the functionality of the card and to serve as an easy to use and
87. ration functions for the timing gain and offset settings which can be executed upon user request The digitizers are never calibrated in an automatic way ie as a side effect of another operation This ensures programmers have full control of all calibrations performed through software in order to maintain proper event synchronization within automated test applications The model DC and DP series digitizers include a high precision voltage source and a 16 bit DAC used to determine the input voltage and offset calibration For accurate time and voltage measurements it is recommended to perform a calibration once the module has attained a stable operating temperature usually reached with a few minutes of digitizer operation after power on Further calibration should not be necessary unless temperature variations occur A full internal calibration of a digitizer can be very time consuming gt 100 s digitizer in particular for the DC2x1A models Therefore several other options are available They are documented in the Programmer s Reference Manual A program can always be started with the digitizer in an uncalibrated state and data taken can be used for many kinds of testing However as soon as good data respecting the specifications of the instrument is required a calibration of at least the current acquisition state is needed The full internal calibration has the advantage that it generates the calibration constants needed for any possib
88. re powering your PE Werty that the LED on your 4cqins module is glowing orange or red when the power is applied Your amp cqirs digitizer rmadule s will be operational after you restart your computer MM 19 Registration of your installation will help us provide you with better support You will also be notified of updates and upgrades All information submitted to Acqiris will be treated confidentially and never be disclosed outside the company User Manual Family of 8 bit Digitizers Page 18 of 68 jie Acqiris Software Setup Registration Please register your software with Acqins By doing so you will receve Notification of product updates and upgrades New product announcements Y au will alzo help us provide vau with the most efficient technical support IF you have already registered a previous version please do send a new registration that will ensure aur records are up to date Acqiis maintains a strict privacy policy our contact information will never be disclosed outside the company Email support support acis cor im Acqiris Software Setup Select Options Select your options below and click Nest to continue Fou check the bos below Setup will prepare a registration email ready to send you can then still decide nat to send it TOU may add any comments to the email as you wish iW Prepare registration email lt Back M est gt Cancel
89. retries on the PCI bus have been observed on some machines Such problems disappear when switching DMA mode off data transfer rate is then about 2 8 MB s User Manual Family of 8 bit Digitizers Page 56 of 66 acqiris Please note that switching DMA data transfer mode off precludes the use of acquisition interrupts The i switch will therefore be ignored when n is used Process Priority When the program checks for an event from the operating system e g to react to user input it can put itself to sleep for a specified period of time This gives other applications more processor time but limits the performance of AcqirisLive in terms of maximum acquisition rate The default is not to go to sleep but this can be overridden to allow better performance for other applications Note that this sleep policy is only in effect while the acquisition is running When the acquisition stops the sleep policy is always reset to the longest sleep period Acquisition Interrupts When performing acquisitions there are 2 possible ways to wait for the acquisition to complete polling or using a hardware interrupt e p Polling AcqirisLive runs as a single thread process After an acquisition is started the instruments are regularly polled to check when the acquisition is complete The user interface is still alive but the latency for reading the data after the acquisition may vary e i Hardware interrupt In this mode AcqirisLive is run as a
90. ris devices present on the system when the NT driver is started Therefore the system is ready to run immediately after booting the computer 2 5 6 MATLAB If you want to use the Data Acquisition Toolbox interface then the Acqiris Adaptor has to be registered This can be done with the following command gt gt Aq Install This command will also generate diagnostic information that confirms that the installation succeeded Since a calibration will be performed the command may take a while to execute If no errors are shown the CallAcqiris dll file was successfully installed You should see messages like this Registering the Acqiris Adaptor aq dll successfully registered AdaptorDllName C Program Files Acgiris bin aq d1l Location AdaptorDilVerston s 1l 2 D I DLL Version AdaptorName ag BoardNames DP240 12767 Either Model Serial Number or 1xn cell InsetalledBoatdlds 70 Board Identifiers for MATLAB ObjectConstructorName analoginput ag 0O 13 ort or nx3 cell Help for CallAcgiris module Syntax CalLAoccguirzsi FuncrtionName Argin ase APQOUC wee List of available functions from this module CallAcqiris SetString instID attribute string Set an attribute value String Followed by more help lines and the next command prompt If there is an error please check your paths under MATLAB and contact us if needed 2 6 LabVIEW RT There is only one Acqiris Driver It supports all
91. rs Page 36 of 68 acqiris Other particularities Model Bandwidth Bandwidth Minimum BW Limiter Maximum into 50 Q Capacitance Rise Time selections Offset into 1 MQ 8 pF Max FS 0 5 V 8 EN BW 200 MHz DP111 500 MHz EN 7 ns ET MHz Max FS 20 5 V DP210 500 MHz 400 MHz 0 7 ns DBW n 200 MHz 8 EN eno E MHz 0 7 ns 25 MHz BW 5 200 MHz Max FS 0 5 V DP212 500 MHz NA 0 7 ns 25 MHz NA BW 5 200 MHz Max FS 0 5 V DP214 20 200 700 MHz DC271 FAMILY ns 500 MHz LU Lam 200 MEZ pen ramy FAMILY pps l oue naan 35 ns 20 200 700 MHz 200 700 MHz DC271 FAMILY FAMILY DC110 250 MHz 250 MHz 1 4 ns 20 V BW 200 MHz 8 mE pess E MHz EN 7 ns un 200 MHZ DC271 FAMILY FC Option DC140 1 GHz NA 0 7 ns 20 200 700 MHz 5V DC271 FAMILY FC Option pe2it 20 200 700 MHz DC271 FAMILY DC271 FAMILY Max FS 50 V 1 MQ DC211A 950 MHz 300 MHz 0 35 ns 20 200 700 MHz 5 V 500 1 GHz typical 509 see remark below 20 V 2 0 5 V typical 14 pF 1 2 ns FS amp IMQ typical 200 V gt 5V 1 MQ FS amp 1MQ DC240 500 MHz 400 MHz 0 7 ns 20 V BW 5 200 MHz 11 pF pet 1GHz NA 035m 20 200 700 Miz C271 FAMILY DC241A 950 MHz 300 MHz 20 200 700 MHz 5 V 50 DC271 FAMILY 1 GHz typical see remark below 20 V 0 5 V Max FS 50 V 1 MQ typical 14 pF FS amp IMO i 200 V gt 5V FS amp 1MQ 11 pF 11 pF pen 1GHz na 035m 20 200 700 mez DC271 FAMILY Use
92. rs Page 51 of 66 acqiris When a Slope box is shown next to the delay section selecting the trigger slope is achieved by depressing either the positive or negative slope buttons The DC271 FAMILY digitizers extend the functionality of the slope section to allow the choice of the window and HF divide trigger modes when the multiple mode slope button is selected When the Window trigger is chosen buttons below it will allow the user to choose between trigger on entering or exiting the window trigger level range The Adv button in this section gives access to the choice of External Trigger range and Bandwidth Limiter for the DC271 FAMILY digitizers It also allows the user to set the offset of the trigger out signal 4 2 7 Acquisition Mode The acquisition mode of the digitizers 1s selected using one of four acquisition mode buttons in the Acquisition section of the control panel Available acquisition modes are Auto Normal single and Stop Acquisitian NORMAL 18 1718 Acg s AUTO NORMAL SINGLE STOP This Acquisition section of the control panel also indicates the number of waveforms acquired per second by the digitizer The use of each of the acquisition modes is described below In the discussion a valid trigger indicates a trigger signal meeting the trigger conditions at a time when the digitizer is armed and ready to acquire data In Single and Normal modes the display will only be updated after each active digitizer h
93. ry AcqirisLinux lib modules where the install script drv install can access it dry install rem to remove the previous installed kernel mode driver dry install add to install the new driver To compile for a new kernel under linux 2 6 issue the following commands cdlinux2 6driverpci make clean all to generate a new kernel mode driver acqrsPCI ko from scratch make install to copy the kernel module where it should reside Note that this version of the loadable kernel module had been tested on Linux kernel versions up to 2 6 13 2 3 2 Special cases If you are running a Linux distribution that doesn t use the standard paths for the load scripts you can load the driver with the command cd AcqgirisLinux drv install load Copy the driver to the module directory as follows cp lib modules acqrsPCI o n lib modules kv ACQIRIS acgqrsPCI o where n is the optional designation of the desired version of the acqrsPCI driver as given above and kv is the appropriate system kernel version 1 e 2 4 20 Then add the following command to rc local sbin insmod f lib modules kv ACQIRIS acqrsPCT o 2 3 3 Environment variables for the Firmware Automatic loading of the firmware needed by 12 bit and AP modules relies on the environment variable AcqirisDxDir pointing to the directory containing the file AqDrv4 ini which in turn points to the directory containing the Firmware bit files Therefore assuming that your F
94. s mounted in a PC is a more delicate issue Because of their mass the cards can vibrate loose unless they are properly secured and braced DP cards held only in the front and on the bottom should not be shipped in their PC However properly mounted DP cards with XP103 fans can be sufficiently well held the Adjustable retainer must be used so as to hold the card in place 1 11 Maintenance The cards do not require any maintenance There are no user serviceable parts inside A periodic calibration can be obtained on request 1 12 Cleaning Cleaning procedures consist only of exterior cleaning Clean the exterior surfaces of the module with a dry lint free cloth or a soft bristle brush If any dirt remains wipe with a cloth moistened in a mild soap solution Remove any soap residue by wiping with a cloth moistened with clear water Do not use abrasive compounds on any parts 1 13 Disposal and Recycling Electronic equipment should be properly disposed of Acqiris Digitizers and their accessories must not be thrown out as normal waste Separate collection is appropriate and may be required by law User Manual Family of 8 bit Digitizers Page amp of 66 acqiris 2 Installation This chapter describes how to install the Acqiris hardware and software for Windows 95 98 2000 NT4 XP National Instruments LabVIEW RT Linux Phar Lap ETS or Wind River VxWorks NOTE For a first time installation Acqiris strongly recommends installing the
95. sis 1 1 DsK 2M 400 s0ps soppm 2V ppro 1GSs 1 1 fiK 8M sooo s0ps SOppm 2V DP111 iGss 1 1 fik 2M 40 sips 2 ppm 3 V pezo 2GSs 1 1 25K ism 8000 sps 2ppm s3V DP211 GS as osek fiom 8X0 T Sps 2ppm 3 V DP212 2GSs 1 1 256Ek lism sooo 5ps 2ppm 3 V praia 2GSs 1 1 25K ism sooo sps 2ppm s2V pp23s 1GsSs 2 2 iek 2M 400 Sps 2ppm s2V pez 2GSs 2 2 ik 8M 800 sps 2ppm s2V pcno 1GSs ia fik sm 800 5ps S ppm 2V m Mo 3m Mo am am Mo m Mo Mo cas 2V DC140 2V pe2it 2V DC211A 22V DC240 3V DC241 2V DC241A 2V DC265 2V DC270 2V pc 2V perma acss 4 4 fisk sM 8X0 Sps 2ppm s2v pezar 2Gss 2 2 isk sM 8X0 Sp 2ppm s2V The indicates a Dual Input module where there is one channel which can digitize the signal on one of the two BNC inputs E e 72 3 3 1 Sampling Rate All Acqiris digitizers contain an analog to digital conversion ADC system that can sample waveforms in a real time sampling mode at rates from the maximum allowed rate down to 100 S s 10 ms per point The sampling rate can be programmed and is selectable in a 1 2 2 5 4 5 sequence i e 1 MS s 2 MS s 2 5 MS s 4 MS s 5 MS s 10 MS s etc The maximum sampling rate shown above sometimes exploits the possibility of combining channels 3 3 2 Acqui
96. sition Memory Data from the ADC is stored in on board acquisition memory The amount of memory in use for acquisition can be programmed and is selectable from 1 point to the full amount of acquisition memory available User Manual Family of 8 bit Digitizers Page 39 of 68 acqiris For technical reasons a certain memory overhead is required for each waveform reducing the available memory by a small amount In order to simplify programming Acqiris provides an interface function which recommends the best sampling rate and the maximum possible number of data points taking into account the available memory the requested time window the number of segments in Sequence mode as well as the required memory overhead To ensure maximum sampling rate and high timing resolution Acqiris strongly recommends the use of long acquisition memories whenever possible For example the model DC110 or DP110 with 2 Mpoints of memory can record a signal over a 2 ms period with a sampling rate of 1 GS s 1 ns per point The fast sampling rate ensures that all high frequency signal components up to the full 250 MHz bandwidth of the digitizer are accurately recorded If the memory were reduced to just 20 Kpoints then the sampling rate would need to be reduced to just 10 MS s 20 000 2 ms to record the same 2 ms period All frequencies above 5 MHz would then be incorrectly digitized and important signal characteristics may be distorted or even completely missed
97. software before inserting the hardware into the PC 2 1 IC414 Installation NOTE If you are going to install an IC414 interface for the first time and are running Windows 98 2000 XP you should follow the procedure below before installing the Acqiris hardware 2 1 1 IC414 Hardware installation hints The PCI 8570 PXI 8570 User s Manual Rev 1 00 section 2 5 gives Hardware Installation instructions CAUTION Turn off the power of the PC the PC may have to be unplugged to ensure that the PCI bus has no power available CAUTION Touch the antistatic package to a grounded object before removing the card from the package Electrostatic discharge can damage the card The standard cable pair provided each have a red connector on one end and a black connector on the other Therefore the correct connection can be made by plugging the Red connector into the LORx socket and the Black connector into the LOTx socket on the PXI module and the other Red connector into the PCI module socket furthest from the PCI card internal base connector and the Black connector into the next socket If you intend to use 64 bit 66MHz transfer to maximize data transfer speed you should cable a bundled link use two standard cable pairs and both the LO and L1 pairs of connectors You should also make sure that you configure the PXI 8570 M66EN Jumper correctly 2 1 2 I1C414 Windows software installation Linux users do not need to read any further since there 1s
98. splay The current channel is selected by clicking on the channel name within the upper portion of the control panel The vertical settings of the current channel and the timebase and trigger of the correspondent digitizer are then indicated A unique name is given to each channel installed on the PCI bus The current channel is indicated by a dark highlight over the name Settings changed on the main control panel will only affect the active channel Always verify proper acquisition setting for each channel prior to collecting data There is a small rectangular indicator button to the left of each channel name in the channel list If this indicator is filled in the channel waveform is active the channel is turned on and displayed in the display window Clicking on this indicator once turns it transparent This deactivates the reading of the data from the channel and clears the waveform display Clicking once again on the indicator turns the channel back on and the indicator is filled in After making such changes the channel data will not be displayed until after the next acquisition The image at the left shows a channel list with four active channels in the system All are turned on and displayed in the display window as indicated by the black indicators at the left The DC271 Chl is the currently selected channel The channel list image at the right shows the same system with the DC271 Ch2 selected as the current channel The other indicat
99. t Coupling can be set for AC or DC The selected setting is shown as an actuated indicator with a green backlight AC coupling blocks DC signal components from the input The AC coupling mode acts as a high pass filter passing frequencies above 10 Hz In DC coupling all frequency components are passed through the input The input voltage offset control applies an offset to the input amplifier in order to better digitize and display signals offset away from 0 volts Signals riding on a DC level can be most accurately characterized when the offset 1s adjusted so that the acquisitions are made about the midpoint of the digitizer s Full Scale Range and when as much of the 8 bit ADC range is used as possible The ability to select an offset voltage enables accurate measurement when offsets are present in the signal The Impedance selection allows the user to choose the appropriate internal input termination of 50 Q or MQ The Adv button in this section gives access to the choice of hardware bandwidth limits for the channel 4 2 6 Trigger Trigger characteristics are set using the settings in the control panel 7rigger section The trigger source setting can be either Internal trigger on any one of the input channels or External trigger on an external input The trigger source is indicated in the display by the name appearing under Source Trigger Ady Edge class Source DC271 Ch hae m Coupling i ooo OOV oc In ord
100. te the modules are in The third step is to specify the number of slots in each crate This is shown below Acqiris GeoMap Wizard l 2 xl Step 1 Crate court Step 2 Bus location Step 3 Crate size Step 4 Module locations How many slots do you have in each crate Select corect nbr include system and empty slots E Crate 1 has 21 Slots Mast gt gt User Manual Family of 8 bit Digitizers Page 61 of 66 acqiris The 4 step consists of arranging the modules of each crate into the correct order The menu shown below is one in which all of this work has been done for the modules of a fully populated CC121 Selecting a position will cause a module to have its red LED turned on Then the Up and Down buttons will allow you to move the module in question to the desired Position in crate E Acgiris GeoMap Wizard SS x Step 1 Crate count Step 2 Bus location Step 3 Crate size Step 4 Module locations Select a row below to light the red LED af the module Move it to the correct position with the buttons Crate 1 PCI Slot Up 7 10 DC271 b et DC271 10072 b 11 Down 14 OF 10068 b 12 18 Oe 10064 b 13 17 OF 10060 b 14 15 DC271 10056 b 15 15 DC271 10052 b 4 14 DC271 100468 5 10 13 OF 10044 5 11 12 OF 10040 5 g 11 DC 10036 D 13 10 DC271 10032 5 14 3 DC271 10028 5 15 B8 DC271 10024 5 4 T OF 10020 4 10 b Oe 10016 4 11 S DC 1001 4 9 4 DC271 10008 4 13 3 DC27
101. ter point of N the waveform displayed in the zoom display window Alternatively the right and left arrows at the bottom of the zoom display window will reposition the horizontal center of the zoom In order to expand the zoom region vertically select the Vertical button on the zoom display and click the In Out buttons Alternatively the up down arrows on the scale indicator just below the vertical button can be used When the vertical scale is expanded the top and bottom lines forming the blue box in the main display window show the extent of the vertical zoom region The vertical position of the box and thus the data region shown on the zoom display may be changed by moving the box vertically with the mouse or by clicking on the up and down arrows at the left of the zoom display window When expanding a waveform to the point where individual data points are seen it may be desirable to use the Connect data points option under the Options menu in AcqirisLive When this option is selected larger data points are drawn on the display and a line connects each point The main display window contains a drop down selector that controls the display type for both the main display and the zoom window There are two modes available the Live Display or the Persistence Display When persistence display is selected all points drawn to the display windows remain on while new points are added from subsequent acquisitions This mod
102. th For an ECL compatible signal terminated on 50 Q to 1 2 V prs set the offset to 1 2 V and the output will be in the range 0 8 V 1 6 VJ 1 18V GND Alternatively to reduce the current drawn from the digitizer the terminations shown here can be used For the DC135 DC140 DC211 DC211A DC241 DC241A DC271 DC271A DC271AR modules a standardized trigger out signal can also be routed to the PXI Bus Star Trigger line User Manual Family of 8 bit Digitizers Page 44 of 68 3 10 Frequency Counter mode acqiris The new DC140 and DC135 digitizers offers an optional Frequency Counter FC mode This option allows the measurement of the average frequency or period of a signal for frequencies up to 400 MHz over a user selectable aperture between 1 ms and 1000 s The accuracy is limited by that of the timebase 2 ppm the short term stability is of 0 1 ppm The accuracy can be improved if an appropriate external reference clock 1s used Frequencies in excess of 100 MHz will be measured using the HF divide by four feature of the trigger circuit A digitizer with the FC option can also totalize the number of triggers during a chosen time interval or a user provided gate signal This can be done for trigger frequencies under 125 MHz and for total counts up to 27 The time interval is measured using the same clock as is being used to drive the digitizer The user gate signal has to be made available on one of the Control I O in
103. the LED on the front panel lights up yellow on the digitizer module with the current channel 4 2 3 Numeric Editor The numeric editor is shown in the control id OU QUE 3 window at locations where numeric values are set The Acqiris Numeric Editor enables easy input of numeric values particularly those ranging over many decades The numeric value can be changed in multiple Ways A number can be typed directly into the white number display area or alternatively the Acqiris Numeric Editor may be used In order to use the Acqiris Numeric Editor click on the green numeric editor icon at the left of the number display A numeric editor control will appear as shown The methods to change the values are 1 Increment or decrement any digit with the arrow buttons by pressing the increment or decrement button When the button is held down the digit will continue to increment or decrement automatically 2 Click on a digit and drag the mouse up or down to increase or decrease the value 3 Typea new value with the keyboard for any highlighted digit Mouse sensitivity mmm Move pointer over digit to be changed AAA AAAAAAA n dincrease range 200 0000000 ns The value is constrained to fall within its allowed range whenever the user attempts to enter a larger or smaller value 4 2 4 Keyboard shortcuts Two shortcuts have been defined to simplify applying changes of a parameter to a group of channels When the mouse is ov
104. the driver If you intend to use an Averager an Analyzer or a 12 Bit Digitizer you must install the Firmware bit files You can either copy them from the Firmware directory of the CD ROM or download them from our WEB site They should be placed in the Firmware subdirectory of AcqirisLinux In the case of the CD ROM this can be done by continuing the above command sequence with the following cp mnt CDRom Firmware bit Firmware 2 3 1 Kernel Mode Driver Compilation For some special kernels for example SMP the kernel mode driver will have to be recompiled on the target system All files needed to compile a new kernel mode driver are in AcqirisLinux linuxdriverpei for Kernel 2 4 or in AcqirisLinux linux2 6driverpci for Kernel 2 6 The makefile can be used for compilation under a Redhat compatible distribution To compile the driver the kernel header files need to be installed The path variable INCLUDEDIR in the Makefile has to point to the correct kernel header files The default path INCLUDEDIR usr src linux 2 4 or usr src linux 2 6 respectively This path usually is a link to the actual header files driver source To compile for a new kernel under linux 2 4 issue the following commands cdlinuxdriverpci make clean to remove all o files in AcqirisLinux linuxdriverpci User Manual Family of 8 bit Digitizers Page 21 of 66 acqiris make to generate a new kernel mode driver acqrsPCT o and also copy it to the directo
105. tude values in Volts The destination folder can be selected or created on any system drive using the Browse button Waveforms will f Binary format be stored in a new folder under the V Raw ADC val ARAM 24 4 MB destination folder The new folder will be R ae Total storage 24 8 MB named AcqirisRun_ date time Each Amplitudes V waveform will be stored in a file with a name channel identifier 1 suffix DO Legnenis ay Oban where 1 goes from 1 to N and the suffix LR indicates the data type If the data is stored in Binary form the suffix will be DK Hep data and an additional ASCII format Era caa awh file is written which contains necessary details about each of the other files Otherwise the suffix will be awd Show waveforms The Autostore operation can be stopped either when the desired number of generations of waveforms 1 to N have been stored or when the total amount of data allowed in any single Autostore acquisition series exceeds the desired value When using segmented memory with Autostore a waveform is considered to be a complete set of acquired segments When storing Amplitudes it is possible to write each segment as a separate column of data in the waveform file This is achieved by clicking the check box option User Manual Family of 8 bit Digitizers Page 55 of 66 acqiris Segments as columns in the Autostore settings window Formatting with segments in columns in Amplitu
106. u first receive your new Acgiris product Special attention should be paid to sections on safety packaging and product handling Before installing your product please ensure that your system configuration matches or exceeds the requirements specified Chapter 2 INSTALLATION covers all elements of installation and performance verification Before attempting to use your Acqiris product for actual measurements we strongly recommend that you read all sections of this chapter Chapter 3 PRODUCT DESCRIPTION provides a full description of all the functional elements of the digitizer Chapter 4 RUNNING THE ACOIRISLIVE APPLICATION describes the operation of AcqirisLive 2 15 an application that enables basic operation of Acqiris digitizers in a Windows 95 98 2000 NT4 XP environment Note AcqirisMAQS is a new software application offering many interesting possibilities for the control of acquisition systems in a single or multi machine environment Ask your salesman or Acqiris for more information Chapter 5 RUNNING THE GEOMAPPER APPLICATION describes the purpose and operation of the GeoMapper application which is needed for some ASBus Multi instrument systems For information necessary for writing you own software to control Acqiris products you should refer to the Programmer s Guide and the Programmer s Reference Manual 1 3 Conventions Used in This Manual The following conventions are used in this manual This icon to the left of text w
107. ut at that time If valid triggers are received at a high enough rate Auto mode behavior differs little from normal mode behavior on the display However if the trigger rate 1s too low or trigger settings are not appropriate for the characteristics of the signal the input signal will not be stable on the display This occurs because the internal auto trigger generated by the digitizer 1s asynchronous to the input signal Auto mode is often used to aid in setup when the input signal must be quickly characterized in order to determine proper trigger settings for Normal or Single mode acquisitions User Manual Family of 8 bit Digitizers Page 52 of 66 acqiris 4 2 8 Timebase and Memory The timebase and memory settings should be chosen together ed in order to optimize the desired sample rate for the acquisition H 2 ps Div In oscilloscope mode the timebase settings range from Memory 10 ns div to 5 S div In transient recorder mode time windows MAX 50000 50 0 K samples of 100 ns to 20 Ks are available when using a card with the af 1 00 segments 9 2 Mpoint memory option Sampling Hate In order to change the timebase click on the white area Interval in the timebase display window and select the desired 10000ns 1 0000GS s timebase from the list Alternatively the Decrement Increment timebase selection buttons may be used in order to change the timebase in steps
108. v4 lib borland AqDrv4 lib msvc AqDrv4 lib AqETS4 lib AqLibETS lib AqRT 4 lib Manuals directory with AqDrv4 HLP ProgrammersGuide pdf Header file for C C Acqiris Device Driver Interface Definitions API Data Structure Header file for C C Acqiris Error Code definitions Header file for Visual Basic Header file for Visual Basic NET VISA types already installed if you have LabWindows CVI already installed if you have LabWindows CVI Lib directory with C C link libraries for major compilers default Microsoft compiler Borland compiler Microsoft compiler Phar Lap ETS library Phar Lap ETS library LabVIEW RT library C driver help ProgrammersReferenceManual pdf ReadMe txt ShortCutNames txt A user oriented ReadMe file with information about the installed software needed for Un Install UserManuall12BitDigitizers pdf UserManuall0BitDigitizers pdf UserManual8BitDigitizers pdf UserManualAnalyzers pdf UserManualA veragers pdf UserManualCC10X Crates pdf UserManualCC121 Crate pdf MATLAB directory with InstrumentSettings AqSettings MATLAB Instrument Settings Configuration file Aq startup m only after 1 run example for use in ToolboxMocalAq startup m User Manual Family of 8 bit Digitizers Page 31 of 66 acqiris daq Aq_install m needed for registration and validation daq Aq_ModeLive m example daq Aq_MultipleAcquisition m example daq Aq_SingleAcquisition m example mex
109. vailable as an option Acqiris endeavors to provide leading edge technology that includes the latest concepts in hardware and software design As such software and firmware used with the products is under continual refinement and improvement All software and instrument firmware is supplied as is with no warranty of any kind Software and firmware is thoroughly tested and thought to be functional at the time of shipment At Acqiris discretion software and firmware may be revised if a significant operational malfunction is detected Products supplied but not manufactured by Acqiris are covered solely by the warranty of the original equipment manufacturer In exercising this warranty Acqiris will repair or replace any product returned to the Customer Support Center or an Authorized Repair Center within the warranty period The warranty covers all defects that are a result of workmanship or materials This excludes defects that are caused by accident misuse neglect or abnormal operation The purchaser is responsible for returning the goods to the nearest Customer Support Center This includes transportation costs and insurance Acqiris will return all warranty repairs with transportation prepaid 1 8 Warranty and Repair Return Procedure Assistance and Support Before returning any Acqiris product for repair please contact your nearest service center for a Return Authorization Number RAN In order to issue a RAN we suggest that you co
110. with each click of the mouse The sample rate and sample interval resulting from the combination of memory and timebase are indicated under the Sampling section of the control panel The Memory setting shows the maximum number of points to be acquired The actual number of points acquired could be less than the maximum number set if the acquisition time window selected fills less than the selected amount of memory at the full sample rate Alternatively in oscilloscope mode if a slower timebase is selected in order to ensure that the selected amount of memory will be filled before the acquisition is complete the digitizer will reduce its sample rate as necessary This action differs from the same case in transient recorder mode where preference is given to the selected sample interval In transient recorder mode the digitizer will continue to allocate more memory with increasing capture times This is done in order to maintain the selected sample interval for as long a time window as is possible given the available memory When the card memory is fully utilized the sample rate will decrease with increasing capture times 4 2 9 Using digitizers of different models simultaneously AcqirisLive features a single timebase 1 e the set of acquisition parameters pertaining to the time axis of the waveform such as the sampling rate and the number of samples It is therefore not possible to specify different timebase settings for different digitizers H
111. with option M2M 2000 with option MIM In Sequence Acquisition mode the user needs to specify the sampling rate the total acquisition memory and the number of segments Note that the Single Acquisition mode is just a special case of the Sequence Acquisition mode with the number of segments set to 1 Sequence acquisition enables successive events which can occur within a very short time to be captured and stored without loss A crucial feature of Sequence Acquisition mode is that it has a very fast trigger rearm time A fast trigger rearm helps produce very low dead time less than 800 ns for the highest available sampling rates between the segments of a sequence acquisition The dead time is the period after the end of an event when the card cannot digitize data for a new trigger event To complement this mode of operation the digitizer can also measure and store the arrival time of each trigger using the information from the on board Trigger Time Interpolator TTI Readout of the individual trigger time stamps makes it possible to determine the time from one trigger to any other trigger in the sequential acquisition The TTI resolution sets the resolution of the trigger time stamps see section 3 3 4 Timing 3 3 4 Timing A crystal controlled timebase is used to clock the ADC system of the digitizers The timebase accuracy is guaranteed as shown in the table at the beginning of this section The digitizers also include a built in Trigger
112. you will find the shortcuts for AcqirisLive manual s etc Select the shortcut folder and click Next ta continue Setup will add shortcut icons to the folder indicated below IF you da nat want to use the default folder vau can either type a new name or select an existing folder from the list Shortcut folder Acqirs Digitize Back Cancel 13 If you have enabled the installation of 12 bit Digitizers Averagers or Analyzers the next screen lets you change the name of the directory where the FPGA firmware will be installed User Manual Family of 8 bit Digitizers Page 15 of 68 jie Acqiris Software Setup Installation Folder Select the installation folder below ls click Next to continue Setup will install the FPGA firmare to the directory listed in the box below To install to a different directory either type in the new path or click Browse to select another directory Install files to this location Browse Space required on drive 21 9 MB Space available on selected drive 3383 MB Cancel 14 AcqirisLive needs the LabWindows CVI 7 0 Run Time Engine to run If Setup has detected that a LabWindows CVI Run Time Engine is already installed on your system it will ask you if you would like to install it locally for AcqirisLive anyway If you are not sure about the version of the CVI Run Time Engine on your system it is recommended to install it locally Click Next to conti
Download Pdf Manuals
Related Search
Related Contents
音響器材貸出について(PDF形式:61KB) ASUS D550MA LV8619 User's Manual Installation User and Service Manual Release R - Yokogawa Weider WSAW10011 User's Manual Kurzanleitung zur Installation GAW¤: Effective AW¤ Programming A User's Guide for GNU Awk Weil-McLain EGH Series 4 User's Manual miniTRACEβ取扱説明書 Copyright © All rights reserved.
Failed to retrieve file