1. accumulators Before installing the system it is to be inspected to confirm that there is no external damage or indication of rough handling during shipment In case of overseas shipments it is recommended that the XH5 is tested in a work shop near the final destination to facilitate the commissioning and allow the operators to become familiar with the unit NOTE XHS5 ME R1 doc Page 3 of 9 Axiom Technologies XH5 User 15711 West Hardy Rd Suite 1 Phone 281 931 0907 It is recommended that the operator becomes familiar with the Hydraulic Schematic Appendix B and have a copy handy during the tests described below to better understand the system s behavior To commission the system follow with the steps listed below i il ii iv vi vii viii ix Xi xii xiii Pre charge 20 CU IN diaphragm accumulator with 500 PSI of Nitrogen Pre charge 5 CU IN diaphragm accumulator with 40 PSI of Nitrogen Add hydraulic fluid to the reservoir approximately one gallon if reservoir is empty Filling is to be done with care not to exceed the High level mark in the liquid gauge Open Explosion Proof Box mounted inside the stainless steel box and install battery module as indicated in Appendix A By doing this the electronic circuit becomes energized and the green LED blinks every second Heartbeat to indicate the electronic circuit is operating without problem Before applying pressure it is recomm
2. Axiom Technologies L L C Telephone 281 931 0907 15711 W Hardy Road Suite 1 Fax 281 231 6562 Houston Texas 77060 www axiomsafety com XH5 USER S MANUAL SELF CONTAINED SINGLE PUMP WELLHEAD CONTROL PANEL Axiom Technologies XH5 User 15711 West Hardy Rd Suite 1 Phone 281 931 0907 GENERAL The XH5 self contained system is a device designed and built for protecting oil and gas production wells It includes a switch gage to detect high and low pressures connects up two electronic external alarm signals as well as a hydraulic interface for fire detection and manual ESD The XH5 is self sufficient and doesn t need external sources of energy or supply pressure for keeping a wellhead open and protected It uses hydraulic fluid for driving the SSV and it has a hand pump and dump valve for controlling production The detection of High and Low pressures is done by a switch gage with adjustable contacts for detecting when the monitored pressure is out of acceptable limits Also the XH5 can be connected to remote shutdown signals such as Auxiliary Remote Shutdown i e a shutdown signal from an external process control panel and Telemetry Shutdown that can be connected to an RTU output signal Both external signals Aux Remote and Telemetry are monitored for wiring loop integrity in such a way that wiring failure will be detected and indicated The electronic circuits are fed by a battery module capable of keepi
3. e gage s needle is now touching the Low Pressure contact The first detected alarm will keep flashing until the operator presses Reset Once the operator presses Reset the system resets the solenoid valve to allow the re opening of the well and flashes the green LED even if the alarm still present However the pending alarm red LED and the green LED will flash alternatively to show the system is not completely clear The system tolerates the existing alarm for 30 minutes before re initiating the shutdown preventing the well from flowing for an unlimited period of time under alarm condition When pressing Test the system respond by flashing the last detected alarm for about two seconds and then it sequentially flashes all five red LEDs to confirm all indicator LEDs are operating without problem The battery module provides two separate voltages 3 6 VDC to feed the microcontroller circuits and 14 4 VDC to operate the solenoid valve and read the remote alarms Both voltages are periodically monitored to confirm the system has the proper battery supply to operate reliably If the battery module shows sign of being discharged then the Green LED and the Low Battery red LED will flash alternatively to indicate the need for replacing the battery module This warning may last for weeks but the operator must replace the battery module as soon as the above alternating LED flashing is detected If the battery module discharges to the po
4. ended that hydraulic fluid is circulated throughout the system to flush any particle and contaminants that could be present within the hydraulic lines With this purpose proceed as follows a Set valve In Service ESD to ESD b Set valve SSV Pilot to Pilot c Pump Pilot SSV in a fast mode for approximately one minute while observing the Pilot pressure gage This gauge should display 0 PSI but the needle oscillates with each pump strike d Set valve SSV Pilot to SSV e Again pump Pilot SSV in a fast mode for approximately one minute while observing the SSV SSV pressure gauge This gauge should stay in 0 PSI Confirm that the plugs on the bulkhead connectors are tight before proceeding with the following steps Set valve In Service ESD to In Service Set valve SSV Pilot to Pilot Press Reset on switch Test Reset Pump Pilot SSV while observing the Pilot pressure gauge Pump until reaching 80 PSI Inspect hydraulic lines to confirm that there is no leakage Set valve SSV Pilot into SSV Pump SSV Pilot pump while observing the SSV pressure gauge Pump until reaching 1 500 PSI Inspect hydraulic lines to confirm that there is no leakage It is normal for the pressure to fall about 10 after finishing the pumping Set valve In Service ESD to ESD to return all pre
5. ile observing the SSV pressure gauge Pump until reaching 1 500 PSI It is normal for the pressure to fall about 15 after finishing the pumping Do not exceed maximum actuator s pressure 7 Check all hydraulic connections internal and external to the panel to confirm that there is no leakage 8 Adjust High and Low Alarm set point on switch gage Closing SSV 9 Turn In Service ESD valve to ESD The system responds closing the SSV Re opening the SSV 10 If any of the red LEDs is flashing Press Reset The Alarm LED stops blinking while the green LED Heartbeat blinks every two seconds 11 If In Service ESD valve is on ESD turn it to In Service 12 Set valve SSV Pilot to Pilot 13 Pump while observing the Pilot pressure gauge until reaching 80 PSI 14 Set valve SSV Pilot into SSV 15 Pump SSV Pilot pump while observing the SSV pressure gauge Pump until reaching 1 500 PSI It is normal for the pressure to fall about 10 after finishing the pumping Do not exceed 2 000 PSI Adjusting High and Low Pressure Alarms 16 Turn red knob to adjust High pressure Alarm to the desired High Pressure Alarm Repeat the same with the black knob to set the Low Pressure Alarm HYDRAULIC CIRCUITS The hydraulic circuits are shown on appendix B ELECTRONIC SYSTEM By replacing most of the hydraulic logic with electronic circuits the most fa
6. ilure prone components are removed and the hydraulic circuit greatly simplified to a few reliable components In this way by having self diagnostic in the electronics and a simplified hydraulic XHS5 ME R1 doc Page 5 of 9 Axiom Technologies XH5 User 15711 West Hardy Rd Suite 1 Phone 281 931 0907 system the XH5 offers a reliability level not seen on any of the typical self contained wellhead control panel Furthermore if a failure would occur the diagnostic and correction of the problem is much simpler because of the simplicity of the hydraulics The electronic circuit and battery module are enclosed in a explosion proof box that makes the system suitable for Class 1 hazardous areas where ignitable mixtures of combustible gases may exist To External Alarms Auxiliary and Telemetry Common Common White To Switch gage Wiring to Black High and Low Explosion Pressure Alarm Proof Box Red ae ee ooo0oo0oo0000000000 O TB2 Fig 4 Wiring to the Operator Interface Module The interface module includes the indicator LEDs and the Test Reset switch The circuits connecting to the Interface Module use energy level so low that they are incapable of igniting the type of combustible mixtures found in the oil industry and the circuits have been designed to meet the Non Incendive criteria When operating under normal conditions no alarms the electronic system flashes the green LED every second hear
7. int where the electronics is no longer reliable it will execute a shutdown for preventing operation under such low voltage condition See the instructions shown on Appendix A for installing the battery module WIRING INTEGRITY Given the safety requirements associated with the XH5 enhanced self diagnostics have been added to insure the integrity of the system and the reliability of the operation XHS5 ME R1 doc Page 7 of 9 Axiom Technologies XH5 User 15711 West Hardy Rd Suite 1 Phone 281 931 0907 To this effect the XH5 monitors the wiring integrity of all alarms circuits including the High Low Pressure alarm gauge and the loop integrity to the remote alarms located external to the XH5 enclosure End of Line Zeners for external alarms Operator Interface Module Alarm 1 Blue wire Common White Wires Alarm 2 Blue wire Fig 5 Operator Interface Module As shown on Fig 5 the XH5 is shipped with the End of Line Zener connected at the external alarms input points When connecting the XH5 to an external alarm device the End of Line Zener is to be removed from the Operator Interface Module and connected in parallel with the external alarm device Please note that when connecting the End of Line Zener polarity is important for proper operation If the End of Line Zener is connected backwards it will cause the corresponding alarm channel to go and remain on alarm condi
8. ng the system operating for five 5 years Reset Test Switch gpm Flow Pressure w i High and Low Pressure Alarm LEDs E High Pressure Alarm j gt SSV Actuator Low Pressure Alarm Pressure Aux Remote Alarm Telemetry Alarm Low Battery Alarm Pulse Indication Green SSV Pilot Pilot Pressure Selector Valve Hydraulic Pump a In Service ESD Selector Valve Fig 1 XH5 Controls Interface XHS5 ME R1 doc Page 2 of 9 Axiom Technologies XH5 User 15711 West Hardy Rd Suite 1 Phone 281 931 0907 The XH5 is built to operate exposed to the elements as all hydraulic components are enclosed in a Stainless steel box while the electronic circuits and battery module are enclosed in an explosion proof box inside the stainless steel box The inside components are shown in Fig 2 Operator Interface Module Diaphragm Accumulator Pilot Pressure Electronic Enclosure Solenoid Valve SSV Dump Valve Pilot Pressure Relief Valve Hydraulic Level Indicator Hydraulic Hand Pump Diaphragm Accumulator High Pressure Fig 2 XH5 Enclosure s Interior INSTALLATION PRELIMINARY STEPS AND TESTS The XH5 is sent with the battery module not mounted to prevent the system from operating while in transit Also as needed to meet shipping regulations the device is typically shipped without hydraulic fluid in the reservoir and without Nitrogen pre charge in the
9. ssures to cero before moving the XH5 to the field for installation FIELD INSTALLATION Typically the XH5 is mounted on one or two poles made of 3 pipe Using two poles is preferred as it would insure safe mounting even if one of the pipe brackets used for fastening the panel to the poles would fail The two poles should have a separation of 10 to 15 25cm to XH5 ME R1 doc Page 4 of 9 Axiom Technologies XH5 User 15711 West Hardy Rd Suite 1 Phone 281 931 0907 38cm center to center The pipe brackets connect to the strut channel mounted on the left side of the panel With the panel firmly mounted proceed to connect the field devices to the rear of the panel The connection to the ESD station can be also connected to a fire plug If the fire plug used does not have a return line some means are to be used to prevent hydraulic fluid from reaching the ground A small amount of hydraulic fluid approximately 3 CU IN or 50 CC will be released in the event of the fire plug responding to a fire OPERATION AND ADJUSTMENTS The operation of the installed panel is as follows Starting Production 1 Set valve In Service ESD to In Service 2 Set valve SSV Pilot to Pilot 3 Press Reset on switch Test Reset 4 Pump Pilot SSV while observing the Pilot pressure gauge until reaching 60 PSI 5 Set valve SSV Pilot into SSV 6 Pump SSV Pilot pump wh
10. tbeat to indicate that the electronic system is operating without problems The connections to the remote alarms is through a single pair of wires and the remote signal may be a dry contact or an open collector or open drain of a transistor that would pull the signal to ground when the alarm is present The End of Line Zener that is mounted on TB1 on the XHS5 ME R1 doc Page 6 of 9 Axiom Technologies XH5 User 15711 West Hardy Rd Suite 1 Phone 281 931 0907 operator interface board must be removed from there and connected in parallel with the alarm device When connecting external alarm signals such as Aux Remote Shutdown or Telemetry Shutdown remove the End of Line Zener Diode and run the wiring to the remote device i e submersible electric pump control panel and install the End of Line Zener in parallel to the dry contact If any alarm is detected the green LED stops flashing the solenoid valve trips to initiate shutdown and the red LED corresponding to the detected alarm starts flashing Once detected the detected alarm is latched in such way that even if the alarm would go away or a new alarm would be detected only the first alarm detected will flash holding the information for the operator to see the cause of the shutdown For example if a High Pressure Alarm would occur the corresponding High Pressure Alarm LED will flash and keep on flashing even if the high pressure alarm would go away and now th
11. tion If the End of Line Zener is disconnected or the wiring to the external alarm signal would fail then the XH5 will read a wiring failure where the corresponding alarm LED would double flash and XHS is initiated CAUTION TO REDUCE THE RISK OF IGNITION OF HAZARDOUS ATMOSPHER H5 ME R1 doc Page 8 of 9 Axiom Technologies XH5 User 15711 West Hardy Rd Suite 1 Phone 281 931 0907 Do not open this enclosure unless the area is known free of ignitable mixture of gases Keep tightly closed when in operation Battery Module is to be replaced only with Axiom Part No AT00000001 Former AT LBP 36144 battery module XH5 ENVIRONMENTAL SPECIFICATIONS Temperature range 40 to 85C Humidity range 0 To 95 max non condensing Altitude 2 000 m max Hazardous Area Classification Suitable for Class I Division 2 Groups C amp D Hazardous Locations Temp Code T3C XHS5 PRESSURE RATINGS Sensing Pressure Ranges of up to 20 000 psi max Solenoid Valve Pressure 100 psi max standard XHS5 ELECTRICAL RATINGS Electrical Source Dual voltage lithium battery module3 6 amp 14 4 VDC Current consumption 20 mA max on 3 6VDC Circuits 0 5 mA 3 A max pulse on 14 4VDC Circuits XHS5 ME R1 doc Page 9 of 9