Home

Redline RDL-3000 Quick Start Guide

image

Contents

1. All provisioning is performed on the sector controller Subscriber Links Enable a wireless connection between the base station and a subscriber and set the uplink and downlink rates UBR Service Groups Define packet filtering at the sector controller Ethernet port and set parameters for broadcast multicast groups Services Define packet filtering at the subscriber Ethernet port and set parameters for subscriber unicast traffic Use the following provisioning functions to set up a Pass through configuration no VLAN support and have the RDL 3000 system transparently pass all Ethernet traffic 3 1 Create Subscriber Link Create a Subscriber Link named Link 1 to enable a wireless link to the subscriber 1 Click Provisioning gt New Subscriber Link in the main menu 2 Enter data for the following fields Link Name Link 1 Peer MAC Subscriber MAC address Use factory defaults for all other fields 3 Click Apply to activate this wireless link Click Links Summary to verify the link has become active 4 Click Save All in the main menu to permanently save changes 70 00160 01 01 Proprietary Redline Communications 2011 Page 4 of 6 March 15 2011 4Gon www 4Gon co uk info 4gon co uk Tel 44 0 1245 808295 Fax 44 0 1245 808299 RDL 3000 Quick Start Guide redline 3 2 Create a Service Group Create a Service Group named Group 1 to forward all Ethernet traffic received on the sector controller Ethernet port 1 Click
2. Configuration gt New Service Group in the main menu 2 Enter data for the following fields Name Group 1 Tagging mode Pass through SC Ethernet Enable Click to check the box Use defaults for all other fields 3 Click Apply to activate this Service Group 4 Click Save All in the main menu to permanently save changes 3 3 Create Subscriber Connections Create a Service named Service 1 to forward all Ethernet traffic received on the subscriber Ethernet port 1 Click Provisioning gt New Service in the main menu 2 Enter data for the following fields Name Service 1 Tagging mode Pass through Use factory defaults for all other fields 3 Click Apply to activate this Service 4 Click Save All in the main menu to permanently save changes The system is now configured to pass Ethernet traffic over the wireless interface RDL 3000 Pass Through Configuration Central ites Remote Network ii i Network Grounding and Surge Protection If you have determined that surge protection is required for your system the following general industry practices are provided only as a guideline Refer to the drawing on the following page 1 The AC wall outlet ground for the indoor POE adapter should be connected to the building grounding system 2 Install a surge arrestor in series with the Ethernet cable at the point of entry to the building The grounding wire should be connected to the same termination point used for the tower or ma
3. 000 system RDL 3000 System Components Available from Redline N e lt Fi G A Ny HA TA a P n 3 RDL 3000 Lightweight Heavy Duty Stand Alone RF Jumper Sector Radio Mounting Kit Mounting Kit Mounting Kit Cables Antennas Subscriber Ethernet Line Outdoor l PoE Power Antennas Protection Ethernet Adapter LP Cable AC Power Cord RDL 3000 System Components Available from Redline Description RDL 3000 radio Model T502 4 940 4 850 GHz 2 5 Mounting kit for RDL 3000 2 Lightweight mount bracket assembly hardware and two 230 mm 9 in RF cables Fits 44 5 to 76 2 mm 1 75 to 3 00 in mast or mounts to flat surface 3 Heavy duty mount bracket assembly hardware and two 400 mm 16 in RF cables Fits 44 5 to 117 3 mm 1 75 to 4 62 in mast 4 Stand alone mount bracket assembly hardware and two 400 mm 16 in RF cables Fits 70 to 120 mm 2 75 to 4 75 in mast 5 All mounting kits items 2 4 include two RF cables with male N type termination 6 Base station sector antenna wide beamwidth Subscriber antenna narrow beamwidth Ethernet cable line protection LP unit Cat 5e shielded outdoor Ethernet cable terminated with RJ 45 connectors Available in 30 m 100 ft or 90 m 300 ft GPS Antenna with mounting bracket and 6 m 19 5 ft antenna cable Synchronization cable and T connector Cable is 6 m 19 5 ft with TNC M connectors 12 PoE power injector with single AC 110 220 VAC inp
4. POWERFUL VERSATILE RELIABLE 7 redline communications RDL 3000 Broadband Wireless Radio Platform Quick Start Guide This guide is provided to aid initial deployment of RDL 3000 systems Refer to the RDL 3000 User Manual and the RDL 3000 Installation Guidelines for detailed information about safety advisories installation and operation of RDL 3000 systems RDL 3000 System Components Antenna l Outdoor Indoor Mounting Equipment Equipment Customer Network Kit amp RF Cables Indoor Ethernet Equipment Cable MMM CPS IAD See Antenna RDL 3000 iiin Radio Drip i Loop Router PoE Ground Synchronization Primary paum Power Lug I O Port Ra utpu Adapter Ohren Ground Outdoor Ethernet Cable Wires All Items ordered separately Supplied by customer NOTICE RDL 3000 System Documentation The RDL 3000 system user manuals are available online at Redline Partner support portal If you can not access the Redline support portal directly contact your Redline partner or sales representative to obtain electronic copies of the RDL 3000 system documentation Adobe PDF format Page 1 of 6 March 15 2011 70 00160 01 01 Proprietary Redline Communications 2011 4Gon www 4Gon co uk info 4gon co uk Tel 44 0 1245 808295 Fax 44 0 1245 808299 RDL 3000 Quick Start Guide redline OmMmmMuNnicatl The components in the following illustration are available for each RDL 3
5. e RDL 3000 IP address or password is unknown or the unit is unresponsive refer to the Long Reset procedure in the Troubleshooting section of the RDL 3000 User Manual 70 00160 01 01 Proprietary Redline Communications 2011 Page 3 of 6 March 15 2011 4Gon www 4Gon co uk info 4gon co uk Tel 44 0 1245 808295 Fax 44 0 1245 808299 RDL 3000 Quick Start Guide redline Step 2 Setup and Enable a Wireless Link The following table contains the minimum set of parameters required to configure an RDL 3000 sector controller and subscriber Parameters should be configured in the order listed Enter values for all required settings on each screen and then click Apply amp Save to activate and save changes before changing to the next screen RDL 3000 Parameter Settings 1 Utilities Options Key RF Plan Enable PMP SC Enable PMP SS gt Product mode RF freq etc mode RF freq etc Options Configuration System Name Net Plan Name for SC Name for SS gt System IP Address Net Plan IP address for SC IP address for SS 3 Configuration System Mode RF Plan PMP SC PMP SS N A 4 Provisioning Subscriber MAC RF Plan MAC address of N A gt Subscriber each subscriber in Links the sector Notes 1 DFS enabled systems only Step 3 Provision Services Ethernet data traffic will not be transmitted over the wireless interface until at least one wireless Subscriber Link one Service Group and one Service have been provisioned
6. er splicing tape 3M Scotch super 88 electrical tape Rubber mastic putty or duct sealing putty Radio Antenna Mast or tower location as required by site survey Equipment must be rated Mast for weight and wind loading of all installed radios and antennas Ground Block Termination for grounding and shields of all conductive cables entering the building Grounding Wire Master grounding system for all indoor and outdoor equipment with 2 AWG through 6 AWG as required and eye terminals for connection to RDL 3000 chassis and mounting bracket i Precision set of screwdrivers cutter pliers and other common installation tools ii Portable computer Windows for RDL 3000 configuration antenna alignment and troubleshooting as required Deploying an RDL 3000 PMP System The following steps are recommended for each installation Step 1 Restore RDL 3000 units to factory default settings Step 2 Configure basic network and radio parameters Step 3 Provision basic services to enable Ethernet traffic over the wireless link Step 1 Restore Factory Default Settings It is strongly recommended to begin by performing a factory reset of the RDL 3000 This action will initialize the system parameters to known values and simplify the setup procedure Login to the RDL 3000 and use one of the following commands Web Click the main menu command Configuration gt Factory Defaults Telnet Enter the command save defaultconfig Note If th
7. st 3 Provide direct grounding connections from the RDL 3000 the mounting bracket and the antenna to the common building ground bus Use the grounding screws provided for terminating the ground wires 70 00160 01 01 Proprietary Redline Communications 2011 Page 5 of 6 March 15 2011 4Gon www 4Gon co uk info 4gon co uk Tel 44 0 1245 808295 Fax 44 0 1245 808299 redline ___ communications Air Terminal Lightning Rod RDL 3000 gt pat RDL 3000 Grounding wey of Antenna amp Surge Protection CAT 5 Outdoor Cable with Drip Loop RDL 3000 and Air Terminal Grounding PoE Power Facilities Adapter Shelter Primary Line Protection LP 70 00160 01 01 Proprietary Redline Communications 2011 Page 6 of 6 March 15 2011 4Gon www 4Gon co uk info 4gon co uk Tel 44 0 1245 808295 Fax 44 0 1245 808299
8. ut single 10 100 Ethernet data port and single 10 100 powered Ethernet port Power cord for PoE power injector Available terminated as NA EU or UK type Note All items must be specified individually as part of each system order 70 00160 01 01 Proprietary Redline Communications 2011 Page 2 of 6 March 15 2011 4Gon www 4Gon co uk info 4gon co uk Tel 44 0 1245 808295 Fax 44 0 1245 808299 RDL 3000 Quick Start Guide redline Customer Supplied Materials Installation of the RDL 3000 equipment requires additional equipment and materials supplied by the customer and or installer The following list is provided as a guideline only and additional materials may be required based on local conditions at each installation site This list is not comprehensive and is provided as a guide only Installation Customer Supplied Items item Equipment Rack Mounting space allocated for the PoE power adapter Must accommodate 2 m 6 AC power cable and routing of Ethernet cable from PoE to local Ethernet network access point 120 240 VAC Reliable 120 240 VAC Total power requirements must be evaluated based Power on individual site configurations Cat 5 Ethernet Connect from PoE power adapter to core network Cables Cable Installation Materials for securing cables to mast protecting cables from abrasion etc Materials including suggested weatherproofing materials Scotch 2200 series of vinyl mastic rolls scotch 130C linerless rubb