Home

ProStreamer user manual

image

Contents

1. 19 sub rack ref 5060 power supply ref 5050 RF bridge for signal loop through power bridge for DC power loop through wall mounting holes mounting brackets bindings for attaching fan unit to the sub rack fan unit ref 5062 mounting screws 312 mm 7 RU INSERTING CAM SLOT Connect the RF and power bridges on consecutive modules to bridge the signal and power to the following modules The CAM slot is inserted with the pit on the top as is indicated below Insert the CAM card with the chip pointing to the left side of the CAM module MODULE OVERVIEW 5202 5203 Q SAT input 1 DiSEqc OG tuner 1 lock LED Q SAT input 2 DiSEqc OG tuner2 lock LED SAT input 3 DiSEqc OG tuner3 lock LED SAT input 4 DiSEqc tuner4 lock LED Q 15 VDC input power indication LED Q GND input Q alarm indication LED Q RJ 45 control port Q RJ 45 streaming port Q mounting screws SAT output 1 for loop through to next module SAT output 2 for loop through to next module SAT output 3 for loop through to next module SAT output 4 for loop through to next module 15 VDC output for loop through GND output for loop through CI slot 5303S T Q only OO 60066000000000 5230 CVBS IN 1 Video IN 1 CVBS IN 2 Video IN 2 CVBS IN 3 Video IN 3 CVBS IN 4 Video IN 4 15 VDC input GND input RJ 45 control
2. factory defaults CCS maen FIRMWARE UPGRADE To upgrade the firmware of the device click the Firmware upgrade menu item 5203 ProStreamer IP DVB S2 CI Factory reset Firmware upgrade DVB S2 inputs MPEG settings Copyright 2011 UNITRON nw Click on the BROWSE button and open the upgrade file Click UPLOAD to send the file to the device and click START FIRMWARE to install the new firmware on the device CONFIGURATION OF THE INPUT DVB S2 INPUT 5202 5203 Go to the LNB Settings menu to configure the 4 LNB inputs 5203 ProStreamer IP DVB S2 CI voltage r2 7 vi vi Copyright 2011 UNITRON nw Input Sequence number of the input also indicated on the front of the actual module Label custom label for each input e g V low or ASTRA 19 2 V Low Voltage The LNB voltage to select the polarization o 13V Vertical polarization o 18V Horizontal polarization Tone LNB tone to select low high band o ON high band o OFF low band DiSEqC control of a DISEqC switch A B C D Band Satellite band o Ku band common in Europe o C band mostly used in the USA Ext Voltage Add 1V to the LNB voltage to compensate the cable losses for long coaxial cables Press APPLYto confirm the parameters Go to the TUNER menu to configure the tuner frequency The modules have 4 independent tuners which can be assigned to every input thanks to a built in
3. multiswitch e Input One of the 4 labels configured in the previous step This selects the satellite input e Frequency Transponder frequency e Baud rate kBaud Press APPLYto confirm the parameters The module will now set the tuner to this frequency Wait until the correct parameters are loaded 19 When the tuner is able to lock on the frequency the list of services from this tran sponder will be shown Language enw Alarm DMH web interface 1 2 4 Release 5203 ProStreamer IP DVB S2 CI Configuration i DVB S2 inputs LNB settings Tuner 1 Tuner 2 Tuner 3 Tuner 4 IP output MPEG settings a Leve GD 39 dBm BER CD E sR GED 1448 Available services Name EUROSPORT HD HISTORY HD FILMBOX HD NOVY HD Spektrum HD HBO HD Travel Channel HD CE Eurosport HD DUT EEEEEEBHES S The status of the tuner is shown e Status o Green tuner locked o Red tuner unlocked e Level input signal level dBm e BER Bit Error Rate e SNR Signal to Noise Ratio dB The table Available services shows all the services found in the transponder e Type Type of data tv TV service J radio service i locked service encoded u unlocked service decoded e Name Service name e SID Service Identifier unique ID for a service 20 CONFIGURATION OF THE OUTPUT Navigate to the P SETTINGS menu to configure the IP addresses atthe output Summary Configuration DV
4. 8 DVB 52 Input 5202 9203 EE ENE 18 bonidguraton ofthe DUEDDLE EE 21 contguratonmoriie MPEG SSN eran nnen dna onai 25 TECHNICAL SPECIFICATIONS 5202 5203 26 TT 9 eee 27 VIN OEA eer ee ee oem ne eee er ne ee A E arene eee es 28 CONDITIONS OF WARRANTY 29 UHF FREQUENCY TABLE seen 30 POWER CONVERSION TABLE eneen earns 31 1 INTRODUCTION THE PROSTREAMER RANGE DVB S 2 REF 5202 5203 4 SAT inputs with 4 active loop through outputs 4 transponders over 4 tuner matrix up to 16 FTA programs up to 12 encoded programs ref 5203 with associated multiservice CAM DVB T REF 5210 5211 1 RF input with active loop through output 4 multiplexes over 4 tuner matrix up to 16 FTA programs up to 12 encoded programs ref 5211 with associated multiservice CAM A V encoder REF 5230 4 A V stereo inputs 4 programs PACKAGE CONTENTS Be sure all items listed below are included E ProStreamer module CAT6 ethernet cable RF bridges except for 5230 P DC bridges DC blocked 75 O loads 5202 5203 E DC blocked 75 O load 5210 5211 AN cables 5230 SAFETY INSTRUCTIONS A SE Read these instructions carefully before connecting the unit To prevent fire short circuit or shock hazard Donot expose the unit to rain or moisture Install the unit in a dry location without infiltration or con
5. A can power up to 9 modules 19 sub rack REF 5060 can contain up to 9 modules power supply mounting in 19 rack or wall mountable bindings delivered delivered with 8 blank plates mounted depending on the configuration 0 06 0 see 9 0 06 O 9 0 O 0 0 9 0 0 0 9 6 O 0 0 O0 9 0 GO 0 9 9 0 O 0 0 GO O 9 0 0 O 9 6 O0 O0 0 9 0 0 9 6 O 0 0 9 O O 0 0 GO O 9 9 0 GO 9 0 0 GO 9 9 9 GO 9 0 O 0 0 9 0 0 9 0 O 0 0 9 O0 eee 0 9 9 9 0 9 Fan Unit REF 5062 voltage 230 VAC essential for proper functioning of the system 2 INSTALLATION OF THE HARDWARE Before mounting install all modules in the sub rack Place the power supply ref 5050 in the uppermost left slot of the rack ref 5060 19 RACK MOUNTING For rack mounting attach the 19 sub rack and the optional fan unit in the rack as indicated by the picture 00 Q Q 09000000 19 sub rack ref 5060 power supply ref 5050 RF bridge for signal loop through power bridge for DC power loop through fan unit ref 5062 19 Rack mounting screws 312 mm 7 RU 10 WALL MOUNTING When mounting the headend to a wall attach the fan unit to the sub rack with the delivered bindings Attach the mounting brackets on the back of the sub rack for the mural mounting 000 6 O 00 000000000 E
6. B 52 inputs Source address of stream IP output 192 168 10 100 IF settings Service assignment MPEG settings Copyright 2011 UNITRON n v e Channel The number of the channel e Multicast address Multicast IP address of the 16 streams These multicast addresses will be needed to receive the streams on a PC TV e UDP port UDP port number e VLAN turn VLAN ON OFF e PCP Priority Code Point a 3 bit field which refers to the IEEE 802 1p priority It indicates the frame priority level Values are from 0 best effort to 7 highest 1 represents the lowest priority These values can be used to prioritize different classes of traffic voice video data etc e VID VLAN Identifier a 12 bit field specifying the VLAN to which the frame belongs 21 22 Navigate to the SERVICE ASSIGNMENT menu to configure the streams Every Prostreamer module except for the 5230 can stream up to 16 services ag a 3 e tg eG GG eG avd ad ad eG a e ag e ts Copyright 2011 UNITRON n v e Multicast address IP address of the stream e Port UDP port of the application e Name Name of the service e SID Service ID Unique number which identifies the service e ON Check this box to enable the streaming of this service uncheck to stop the streaming e CAM Check this box to pass this stream through the CAM slot for decryption e Icons GQ adda new program to the list
7. ace 1 2 4 Release 5203 ProStreamer IF summary Active services Name FILMBOX HD HISTORY HD NOVY HD HBO HD Spektrum HD Travel Channel HD WE Travel Channel HD CE HISTORY HD BG BEBBBHBBEs Copyright 2011 UNITRON n v GENERAL CONFIGURATION GLOBAL Here you can configure the hostname of the module This name can be used to ac cess the module by simply typing it into your browser as the address and surf to it This is more convenient than using the IP address DMH web interface 1 2 4 Release Configuration Global Host name Export configuration IP address Factory reset Firmware upgrade Language enw Alarm e 5203 ProStreamer IP DVB S2 CI DMH 169 254 221 78 DVB S2 inputs MPEG settings Copyright 2011 UNITRON n v Just enter http hostname into your favorite browser not case sensitive and press enter EXPORT CONFIGURATION The configuration can be exported as an xml file amp johansson Language en v Alarm 6 DMH web interface 1 2 4 Release 5203 ProStreamer IP DVB S2 CI The export file is ready and available Download Configuration Global Export configuration Factory reset Firmware upgrade DVB S2 inputs MPEG settings Copyright amp 2011 UNITRON n v Press DOWNLOAD to save the xml file 16 FACTORY RESET All settings can be reset to default by means of a factory reset Are you sure you wantto resetthis module to
8. densation of water Donot expose it to dripping or splashing Do not place objects filled with liquids such as vases on the apparatus If any liquid should accidentally fall into the cabinet disconnect the power plug To avoid any risk of overheating Install the unit in a well aery location and keep a minimum distance of 15 cm around the apparatus for sufficient ventilation Donot place any items such as newspapers table cloths curtains on the unit that might cover the ventilation holes The unit must not be exposed to any source of heat sun heater Donot place any naked flame sources such as lighted candles on the apparatus Do not install the product in a dusty place Use the apparatus only in moderate climats not in tropical climates Respect the minimum and maximum temperature specifications To avoid any risk of electrical shocks Connect apparatus only to socket with protective earth connection The mains plug shall remain readily operable Pull out power plug to make the different connections of cables To avoid electrical shock do not open the housing of adapter Maintenance A Only use a dry soft cloth to clean the cabinet A Do not use solvent For repairing and servicing refer to qualified personnel RE Dispose according your local authority s recycling processes ACCESSORIES Power Supply REF 5050 operating voltage 15 V max output current 10
9. elete services Multicast address Port 239 0 1 1 239 0 1 2 239 0 1 3 239 0 1 4 239 0 1 5 239 0 1 6 239 0 1 7 49152 49152 49152 until the bar becomes green again eg E ERE Bee Name EUROSPORT HD HISTORY HD FILMBOX HD NOVY HD Travel Channel HD CE Eurosport HD DUT HISTORY HD 0 100 Mbps SID 5041 ty c t c ig c i ce ES EI EI EI EI EI EI EI CONFIGURATION OF THE MPEG SETTINGS This menu item is only visible with modules having a DVB S2 input johansson 5203 ProStreamer IP DVB S2 Cl DVB S2 inputs IP output Copyright 2011 UNITRON nv e Forward EPG tables Forward Electronic Program Guide tables to the TV s e CAS forwarding Forward the Control Access System tables CAT EMM ECM to descramble the programs with a set top box o CAT Conditional Access Table o EMM Entitlement Management Message o ECM Entitlement Control Message e Block others Block private data PID share Enable sharing of the PES PCR and ECM 25 26 4 TECHNICAL SPECIFICATIONS standard IEEE 802 3 10 100 Base T OUTPUT protocols Multicast IP UDP capacity up to 16 simultaneous streams up to 100 Mbps RF input with loop through 8 x female F power supply with supply voltage 15 VDC LED indications 4x lock status power alarm de multiplexing of up to 4 transponders PSI SI parsing
10. johansson user manual ProStreamer 5202 5203 5210 5211 5230 e e amp ProStreamer AIV J johansson 1 johansson 1 johansson J johansson johansson No part of this manual may be copied reproduced transmitted transcribed or translated into any language without permission Unitron reserves the right to change the specifications of the hardware and software described in these manuals at any time Unitron can not be held liable for any damages resulting from the use of this product Specifications are subjectto change without notice 09 11 O Unitron Frankrijklaan 27 B 8970 Poperinge Belgium T 32 57 33 33 63 F 32 57 33 45 24 email salesQjohansson be www johansson be www unitrongroup com CONTENTS 1 INTRODUCTION er 4 package contents EEE 5 safety instructions ccccccccescssescseseesesssscseseseeseesesessesesessesaesesaesesaseeseseesaestsecausecacsesaseeeateesases 6 FEN 8 INSTALLATION OF THE HARDWARE I FV a DUI ER 9 FE EEE EE 10 Tie AN ES RR 11 Hode ENE asken ie 12 WEBGUI setting the name of the VICE nnn 14 logging into the device tnnt nnn tnnt nnne 15 general configuration tnn tnnt nnn tnnt nnne nn nnns 16 adi MNT 16 gt export configuration ccccccsescssssescsesssscscsessescsesesecsesesesessesesecacsesesavsususesassesesasanseseearenses 16 ae EO AE MA Q 17 SN IT Ware UDO EN AE aE AE AN 17 conugurauam LAE 1
11. of services update the current service this icon will become active if some setting has changed delete the service from the list pressing this icon will remove the program permanently you can add it again Press the GY button to add a new service A list of available services from all 4 tuners will appear on the screen od OM CO BO ES EI IE ET ES EE EC Click on the service to be added and wait until the service is loaded into the list The list will be refreshed and the added service will appear 23 24 johansson DMH web interface 1 2 4 Release 5203 ProStreamer IP DVB S2 CI Language env Alarm o CED CIT Li CHED DVB S2 inputs IP output 1 IP settings 2 Ga Service assignment Cem T gt s a Q 8 B You can add up to 16 programs as long as the total bitrate is lower than 100 Mbps The bitrate is shown in the bar on the bottom of the SERVICE ASSIGNMENT page IF bitrate If the bar is green the total bitrate is good and the chance of having an overflow is quite small However if this bar becomes orange this means the bitrate is close to an overflow This will happen if the total bitrate is higher than 85 Mbps If this hap pens it is advisable to delete some services until the bar becomes green again If the bar becomes red there is an overflow This can be due to the fact that the total bitrate exceeds 100 Mbps or there can be a CAM overflow D
12. only way to connect to the module later on It s advisable to print this name and label the devices e After you press APPLY the module will restart This will take about 25 seconds Afterwards you can surf to the new name you just entered to connect to the module e Repeat this procedure with the next modules 1 at a time e When all modules have a new name you can connect all modules to the same network The modules will now get a new IP address but you can connect by surf ing to the right name the unique name you gave the module in the previous steps LOGGING IN TO THE DEVICE Open your network browser and surf to the name of the module You will now log in to the module After logging in the Summary window appears status Language enw Alarm e 4 r DMH web interface 1 2 4 Release 5203 ProStreamer IP DVB S2 CI LE D Configuration Name DVB S2 inputs IP output MPEG settings FILMBOX HD HISTORY HD NOVY HD HBO HD Spektrum HD Travel Channel HD WE Travel Channel HD CE HISTORY HD BG Egso s8IScs Copyright 2011 UNITRON nw On this screen you see all the services streamed by this module The type of module the status and the language are visible on every screen In the picture above the status LED is green indicating that there are no alarms The alarm status is shown when you move over the status LED with your mouse IB johansson Language enw Alarm DMH web interf
13. port RJ 45 streaming port mounting screws stereo audio IN 1 stereo audio IN 2 stereo audio IN 3 stereo audio IN 4 115 VDC output for loop through GND output for loop through power indication LED alarm indication LED 5210 5211 tuner 1 lock LED tuner 2 lock LED tuner 3 lock LED tuner 4 lock LED power indication LED alarm indication LED Q Terrestrial input 15 VDC input GND input RJ 45 control port RJ 45 streaming port mounting screws terrestrial output for loop through to next module Q 15 VDC output for loop through GND output for loop through CI slot 5211 only 000000 000060 e 3 WEBGUI SETTING THE NAME OF THE DEVICE When first connecting the modules be sure to follow this exact procedure Connect the first module in the rack with your PC using an RJ 45 Ethernet cable without using a switch f p Lf Sses eee edo o OOH XM d WV e Open a browser and surf to START dein D ntp dmh You will now enter the webGui Go to the Configuration gt Global menu Language enw Alarm e 5203 ProStreamer IP DVB S2 CI Pic RN Hostname DMH Export configuration i IP address 169 254 221 78 Factory reset Firmware upgrade DVB S2 inputs IP output MPEG settings Copyright 2011 UNITRON nv e Change the name START to another name Be sure to choose a logical name and don t forget this name This name is the
14. r or replace the product Return the product to your local dealer for reparation THE WARRANTY IS APPLIED ONLY FOR DEFECTS IN MATERIAL AND WORKMANSHIP AND DOES NOT COVER DAMAGE RESULTING FROM Misuse or use of the product out of its specifications e Installation or use in a manner inconsistent with the technical or safety standards in force in the country where the product is used Use of non suitable accessories power supply adapters Installation in a defect system e External cause beyond the control of Unitron N V such as drop accidents lightning water fire improper ventilation THE WARRANTY IS NOT APPLIED IF Production date or serial number on the product is illegible altered deleted or removed e The product has been opened or repaired by a non authorised person NOTE Date of production is MMYY format example 0411 April 2011 For the serial number barcodes the date corresponds to the 4 first numbers 29 TV band Frequency MHz 30 HV 75 O dBuV mV750 dBuv V750 BET 31 UN TRON www unitrongroup com UNITRON NV Frankrijklaan 27 B 8970 Poperinge Belgium T 32 57 33 33 63 F 32 57 33 45 24 sales johansson be www johansson be
15. transport PID filtering remapping capability stream processing regeneration of PAT PMT tables EMM ECM pass through IP UDP encapsulation of up to 16 MPEG streams PERFORMANCE standard IEEE 802 3 10 100 Base T OUTPUT protocols Multicast IP UDP capacity up to 16 simultaneous streams up to 100 Mbps RF input with TT loop through power supply with f CONNECTORS loop through 4 x banana socket de multiplexing of up to 4 multiplexes PSI SI parsing transport PID filtering remapping capability stream processing regeneration of PAT PMT tables EMM ECM pass through IP UDP encapsulation of up to 16 MPEG streams PERFORMANCE 2 20 OUTPUT CONNECTORS GENERAL PERFORMANCE OPERATING TEMPERATURE DIMENSIONS standard protocols 4 streams capacity video 4 x CINCH audio 4 x jack f 3 5 mm stereo m RF input with loop through supply voltage 15 VDC LED indications power alarm encoding video MPEG 2 transport audio MPEG 1 stream processing IP UDP encapsulation of 4 MPEG streams 0 to 40 C SRU x 8TE x 195 mm 5 CONDITIONS OF WARRANTY PERIOD OF WARRANTY Unitron N V warrants the product as being free from defects in material and workmanship for a period of 24 months starting from the date of production indicated on it See note below If during this period of warranty the product proves defective under normal use due to defective materials or workmanship Unitron N V at its sole option will repai

Download Pdf Manuals