Liebert GXT3 - Emerson Network Power
Contents
1. Liebert GXT3 Quick Start Guide 6000VA RTL630 Models The Liebert GXT3 is shipped with the following items e Terminal Block Communication terminals e Compact disc with o Liebert MultiLink o Configuration program o User manual electronic version e USB cable one 2m 6 1 2 ft long e Rack handles with mounting hardware e Plastic tower support base one set e Plastic Bezel e Warnings safety instructions booklet and WEEE recycling sheet ISO 14001 compliance If the UPS is intended to be installed in the Tower orientation locate the support base and spacers then assemble the two stand assemblies with an even number of spacers in each assembly Insert the UPS between the support base assemblies with adequate space between the assemblies as shown in the picture below Note the display should be located on the upper half of the unit in the Tower orientation To rotate the display with the bezels removed depress the grooved tabs on the sides and rotate it 90 degrees clockwise f the USP is to be installed in a rack enclosure follow the instructions provided with the rack mounting hardware for proper installation Upper Bezel Status Indicators and Controls Lower Bezel and Battery Access Door The UPS is cord and plug connected using a L6 30P input plug All wiring should be done in accordance to all local and national electrical codes The UPS is equipped with output receptacles connect the equipment to be protected to th
2. e output receptacles The GXT3 6000RTL630 is compatible with IT Power Systems To configure the unit for operation on the IT Power system remove the 2 screws securing the cover plate in the lower right hand side on the rear of the unit and disconnect the jumper then replace the cover and secure with the screws IT Power System Connector with cover removed s EMERSON Network Powe 1 SL 23185QS6L630_RevO_09 2012 The Liebert GXT3 6000 VA models ship without the internal battery installed Located the internal battery kit model number GXT3 240BATKIT and follow these steps to install the battery 1 Loosen and remove the screws on the battery door and remove the battery door and set aside the screws and door for reassembly 2 Insert the two battery trays and connect the plugs to the mating receptacles 3 Gently push the battery wiring into the compartment making sure that the wiring will not be pinched when the battery door is reinstalled 4 Reinstall the battery door and secure using the screws that were removed in step 1 5 Locate the plastic bezel from the shipping box and attach the bezel to the UPS taking care to align the fastening clips on both ends before inserting them into the holes 6 If your application requires the use of external battery cabinets for longer back up time requirements connect the first battery cabinet to the UPS with the cable provided with the battery cabinet Note it does not matter which connec
3. es attention In addition to the fault indicator being illuminated one or more of LED segments of battery level indicator will also be illuminated to provide a diagnostic aid to the user as shown below A B C The descriptions are listed in the following table Indicator Diagnosis Audiblealarm __ gt Z gt A___ On bypass due to over temperature condition 1 second beep every 4 seconds B On bypass due to DC bus overvoltage 1 second beep every 4 seconds _ C On bypass due to DC DC power supply failure 1 second beep every 4 seconds C D C E A amp C mn PFC failure 1 second beep every 4 seconds On bypass due to inverter failure 1 second beep every 4 seconds E A C E A amp B UPS Failure includes dual fan failure single fan failure under certain conditions and battery charger failure and continuous alarm C amp E A amp C CRE UPS shutdown by command from communication USB or Liebert IntelliSlot port no audible alarm AC Input Indicator LED flashing N reverse Battery Indicator Internal battery source not available continuous audible alarm check battery Flashing connection power down and reboot UPS a Utility power voltage or frequency is out of tolerance bypass is unavailable Single Phase UPS amp Server Cabinets Technical Support liebert upstech emerson com 800 222 5877 Outside North America 00800 1155 4499 Emerson Network Power Worldwide Locations Un
4. ited States Europe 1050 Dearborn Drive Via Leonardo Da Vinci 8 P O Box 29186 Zona Industriale Tognana Columbus OH 43229 35028 Piove Di Sacco PD Italy 800 222 5877 39 049 9719 111 Fax 39 049 5841 257 Asia 29 F The Orient Square Building F Ortigas Jr Road Ortigas Center Pasig City 1605 Philippines 63 2 687 6615 Fax 63 2 730 9572 5 EMERSON 4 SL 23185QS6L630_Rev0_09 2012
5. tor is used on the battery cabinet f more than one battery cabinet is used the additional cabinets then connect to the adjoining battery cabinet Battery Kit Handle Internal Battery Kit 1 of 2 GXT3 240BATBKIT Output Circuit Breakers Liebert GXT3 UPS AA GXT3 6000RTL630 gt m pe External Battery ele Cabinet Connector for Maintenance GXT3 240VBATTUL Bypass Breaker IT Power System Input Circuit Breaker Access Cover s EMERSON Network Powe 2 SL 23185QS6L630_RevO 09 2012 The Liebert GXT3 UPS is ready to be powered ok a eS Ensure the maintenance bypass breaker is in the open position and that the guard is secured in place Ensure that the REPO connecior on the rear of the unit has a jumper between pins 1 2 of the REPO connector or properly wired to an Emergency Power Off circuit normally closed Install any optional Intellislot communication card into the Intellislot port on the rear of the unit Close the input breaker in the panelboard that provides input power to the UPS Close the input breaker on the rear of the UPS unit Note the UPS will now have power and the AC Input indicator on the display should illuminate The UPS will also begin to charge the internal batteries at this point so there will also be battery capacity LEDs illuminated The Liebert GXT3 UPS has customizable settings that might be required depending on the application Please review the CD that ships
6. with the UPS unit for the steps to use the configuration program and make any necessary changes Once that is complete proceed to the next step Close all output breakers on the rear of the UPS If external battery cabinets are used close all breakers on the rear of each battery cabinet Press and hold for about 4 seconds the ON button on the UPS display Note this will apply power to the output receptacles via the internal bypass and the bypass indicator will be illuminated along with an audible beep Over the next several seconds the UPS will perform the self checks and startup routine then automatically transfer the connected equipment to the inverter power Once that is complete the bypass indicator will turn off and the inverter indicator will illuminate The UPS is now running in normal operation mode providing protected filtered power to the connected equipment Battery Level Indicators Load Level Indicators Fault Indicator A Nea AT zi aie Bypass Indicator AC Input Indicator Inverter Indicator On Alarm Silence Manual ry eta cxt Battery Test Button Na anal oy of 6000VA otandby Manual Bypass Button Battery Indicator Pp he EMERSON 3 SL 23185QS6L630_Rev0_ 09 2012 Troubleshooting The following symptoms indicate the Liebert GXT3 is malfunctioning e The relative indicators illuminate indicating the UPS has detected a problem e An alarm buzzer sounds alerting the user that the UPS requir