1. Green light DMX signal OK or from the machine Out no DMX signal Flashover DMX signal error Red lights Medium speed flash menu setting mode Express flash software cpu failure Traffic lights at the same time liang Address setting mode Traffic lights flash alternately the host Control Panel LED Display Signal Description Maintenance When the camera has broken and other damage should be promptly replaced When the light bulb when there is deformation of the damage should be immediately replaced When the lights brightness decreased the bulbs may have to use the time limit should be the timely replacement of aging light bulb has burst danger When the lamp will not boot check whether the lamp power supply fuse blown such as blown fuse fitted on the corresponding specifications can 6 35X32 T15A 250V Lamps inside the motherboard has three fuses specifications respectively X axis and Y axis circuit boards circuit boards one each 6 3A 250V speed melting 5mmx20mm and the motor drive circuit board and a 4A 250V fast melt 5mmx20mm Attention to the need to use the same specifications of the fuse Lamps equipped with overheating protection device when the overheating protection device will automatically cut off power supply when this happens check whether the normal operation of the fan fan fans and whether or not there is dust plug the Net to find out after the start troubleshooting lamps But take note that qualifi
2. control from the controllers DMX output to connect to the first machine from the DMX input and from the first DMX output from the machine connect to the second machine from the DMX input and so and so on until all the connections from the machine completed and then loop connecting plug at the last output signal lamps to complete the connection controller mode In the Controller mode the last DMX output lamps have to connect DMX loop inserted This loop inserted Canon XLR 2 pin plugs with a 3 pin connection between a 1200 OHM about the resistance as in the figure below Play Play this loop at the last output on the lamp which can effectively avoid the DMX512 signal during transmission noise and reflection phenomena PIN 2 FIM 3 Connect map DMX DMX channel for controlling the content 575 W moving head lights have 12 chanels receiving the international standard DMX512 signal As follows Channel DMX Features O O ane 182199 Red 2 Rotating Gobo Lineary dimmer 0 100 white Tm oos 000 255 Pan 16Bit fine Pan Fine T Tilt 000 255 Tilt rotation 8 16Bit Tilt Fine 000 255 Tilt 16Bit fine 9 Pan amp Tilt Speed 000 255 Pan tilt speed fast to slow 051 101 by 102 152 Prism rotation fast to slow 204 255 prism m 0 254 m dd All the machine reset Restart Control 255 after stopping 10 seconds Prism prism Rotatom Control Panel LED Display Signal Description
3. CKLite 12CH MOVING HEAD LIGHT Item No CK 403 USER MANUAL C www cklight com cn O Copyright C Note This instructions include the important information how to safely install and use After reading carefully please operate it as required At the same time please keep a proper record of this specification in case of necessary Firstly thanks for buying our professional light products This moving head light is just the perfect combinations of excellent human nature and industrial design beautiful and elegant By using aluminum alloy and high temperature engineering plastics design the Light body has a good cooling effect especially with the ultra quiet cooling fan This machine used electronic positioning technology All the products are according with CE standards adopting international standards DMX512 signal control Its widely used in television disco song and dance halls nightclubs and other indoor places The product has perfect performance and intergrity packing All users should be strictly comply with the warning and operating instructions as stated Or we aren t in charge of any result by misusing Any damage resulting by misuse is not within the Company s warranty Any fault or problem caused by neglecting the manual is also not in the charge of dealers If the manual has technology changes forgive to have no notice Appurtenance The following attachment has been packaged together with the lamp Ple
4. ase Check XLR 3 core signal lines 1PCS Power cord 1PCS The instruction 1PCS Auxiliary metal gobos Option 4PCS Hanging hook Option 2PCS Before your first using please check whether it has any damages caused by the transportation If occuring Please don t use and contact with the dealer or manufacturer as soon as possible This product only apply to indoor places and the defend level is IP20 Keep it dry avoiding moisture overheating or dusty environment Prevent the light from water and other liquids Please dont directly install lamps on the surface of the nomal combustible material NW The qualified professionals are allowed to carry out the lamp installation operation and maintenance but they must guarantee to operate in strict accordance with the instructions referred to Lamps should be installed in a well ventilated place at a distance of 50 centimeters or more with the walls At the same time please check if the fan and ventilation holes are unobstructed Please don t directly project the lamps on combustible objects Keep more than 3 meters between the lighting and exposured objections 3m E Please don t look directly at the lamp light source especially for the epilepsy patients in order to avoid damages to the eyes Please do not open it to repair by yourself The person having the appropriate qualifications are allowed to carry out the operation Before installing make sure the using supplied v
5. ed technical personnel are allowed to carry out maintenance work Chip design in order to maintain smooth rotation and smooth exercise focusing lens it is recommended to rotate every two months to design a small bearings and focusing lens first two rail lubrication Should be used for good and high temperature grease Lamp cleaning In order to ensure reliable use of lamps to maintain clean the lamp is very necessary Cooling fan should be clean once every 15 days Internal and external optical lenses reflectors and filter cleaning coating must be carried out periodically to optimize light output efficiency Do not use any solvent containing the chemical constituents of cleaning filter coating Cleaning operation of the lamp as the freguency and use the surrounding environment With a soft cloth when cleaning and general cleaning products for cleaning glass it is recommended at least every 20 days once clean external optical system at least every 30 60 days of a clean internal optical system Do not use alcohol and other organic solvents to clean lamp shell so as to avoid causing damage General Troubleshooting Failure description measure 000 power fuse Fail to start intact bulb the normal lamp isnt 1 Inspect DMX start address setting controlled by the controller 2 check XLR signal lines Inspect the dust and oil of the fans whether the dust Intermittent working plug fans and Nets fans Dim light 1 buble s expi
6. oltage is in line with the lamp voltage Each lamp should be properly grounded and installed in accordance with the relevant standards Please don t connecte the lamp to any other dimming device Please don t use the power cord which has injuried insulating layer At the same time don t conect the power cord to other wires When not using or cleaning the lamps please take the power cord plug and then unplug the power cord not forcing to drag or directly dropping the power cord Keep bulbs clean do not directly contact with the glass bulb by hands There is a insurance rope connecting hole at the bottom of the lamps Based on the safety reason please connecte the insurance rope through the hole to have a auxiliary intallment This product use discharge lamp based on the characteristics of the discharge lamp please restart it after turning off lamps for 15 minutes untill full cooling Frequent switching will reduce the life span of lamps and bulbs intermittent useing will improve the life of bulbs and lamps Please do not run the lights before installing the bulb There are no any parts users can repair inside the lamps Before operating Please check if all of the cover plate or shell is well installed the screw has been reliable on tight Prohibit the plate or shell to open the case of the use of lamps If you have any questions or suggestions please timely contact the Company or distributor Key Before having any in
7. ry the brightness decrease 2 check whether the optical system is clean mi Clean the dust and oil of the light bulbs lenses and Beam impurities halo other components 1 Check whether the lens is ruptureing 2 Cleaning dust or oil Serious beam distortion Main technical parameters According to your first product model you only need to refer to the sign project CM575 Input Voltage 220V AC 50Hz Consume Power 750W Lamp HMI575 discharge Color Basic color 7 color white adjustable speed rainbow effect Gobo rotation rotating gobo wheel 7 gobos white bi directional rotary at variable speed Prism prism Variable speed rotation Dimmer strobe dimmer 1 7 times second Focus Electronics linear zoom Rotating angle horizontal 540 vertical 270 Control way DMX512 12 chanels Operation modes stand alone mode the controller mode Master Slave synchronization mode Other functions adjustable horizontal vertical speed Housing aluminum alloy high temperature engineering plastics Net Weight 27 kg Packing Size 560 470 610mm Professional Stage Lighting
8. stallation repair and cleaning make sure that power has been cut off Structure and installation of lighting With 4 attached hanging hooks quick knobbing Have 2 hanging hooks installed at the bottom of the lamp and then hanging lamps on the stable bracket Tighten up the hanging hook bolt and fix the entire lamp Please confirm that it has a solid and reliable installation and ensure that the hoisting position has sufficient strength to bear the weight of the lamp For security reasons please connecte the insurance rope through the hole to have a auxiliary intallment Warning hanging hook is only used in lifting the lamps Prohibited taking the hanging hook as handle carrying the lamps Be sure to use the handle Install replace light bulbs As it s shown release the the screws on the cover of the lamp body and open it Opened two light bulbs screw nut remove out the old bulb When removing it is recommended to remove one side at first Fitted with new light bulbs tighten two bulbs nut Note When loading a new light bulb the hands can not directly contact the spherical body of the lamp so as not to affect luminous efficiency there is a protuberance on the buble when installed we must let the protuberance is vertical to the rear cover with a fan After re installing equip with the cover and tighten screws Key The lamps used high pressure discharge lamp with external triggers When using the light bulbs Please read
9. the Guide Power Connection Connect Power cord as following methods L FireWire brown line E GND yellow green two color line N midline Blue Line Please note that power supply voltage and frequency comply with the ones marked on thelogos of lamps When more than one lamp are used propose that each lamp s power is connected separately so that we can have a separate on off control Key Ground wire must be yellow green two color lines safely connected to the ground electrical installation shall comply with all relevant standards Control signal connection DMX OUT DMX IN MX 51 DMX 512 PIN FUNCTION is gin 2 1 1 2 2 DATA RES 3 DATA DMX OUT Controller as well as lamps and lamps with the lamps must be used between the link is not less than 0 5 mm in diameter two core wire with shielding Please use 3 core random incidental or 5 core XLR plug Block DMX512 output connected to the lamp entrance XLR plug Block and wire connection between the list such as shown in the figure above It should be noted that when connected to XLR Plug Block 3 of the core or core 5 should not in contact with the inner shell and core and between cores can not touch In addition to the list as shown in the figure above connection methods XLR plug XLR Line of Control Block and should not in any other way connected Lighting 1200W receive international standard DMX512 1990 control signal XLR XLR to use the line of