Gst-Def M2.2 Defining Software

image

Contents

1. Fig 16 REC We Action Mode Effect Dev Device QTY Delay Time 00101716 D oo After clicking 53v Modify the equation will be added to the list at the bottom Then add the next equation For similar devices customers can use Fuzzy Logic to save our work It means for these similar devices we use only one Fuzzy Device instead of inputting them one by one Click lt Fuzzy Devices gt to start the function as shown in Fig 17 W Fuzzy Devices Zone 01 Zone 1 Page 10 Cancel GstDef M2 2 Defining Tool qs T Eo User s Manual The Intelligent Solution 4 3 5 Customize Device Type Device Pattern WpLoadAll Default duit 2011 8 6 13 45 Fig 18 Choose the node of the tree structure at the left of the main screen and click lt Device Type gt button the screen in Fig 18 will pop up Function of tool bar buttons are as follows Import Importing ini file with saved device type Save Saving the current device type into current database so that the device type doesn t change when running the software next time Save As Saving the current device type as an ini file Down Downloading the selected device type to the FACP lt DownAll gt Downloading all currently defined device types to the FACP UpLoad Uploading device type to the computer lt UpLoadAll gt Uploading all device types to the computer Default Restoring the default device type Cancel Cancelin
2. 4 3 4 4 General In case of fire the FACPs will act according to the pre programmed equation There are TWO default actions that do not need to be defined 1 In case of fire in a zone zonal sounders will be started immediately Page 8 GstDef M2 2 Defining Tool qs J A User s Manual The Intelligent Solution 2 In case of fire in a zone the panel outputs Sounder circuit output fire alarm output amp F P E will be started immediately Clicking Equations under FACP Net gt will get into equation definition as shown in Fig 14 and Fig 15 ad oE SB SB Hew Insert Dey Delete Dey Save Modify Save Hew Fig 14 lt New gt Add a new equation lt Insert Dev gt Add a device into the condition or result Delete Dev Delete a device from the condition or result Save Modify Save the current equation temporarily Save New Easily add a similar equation into the temporary database A 3 X Upload UploadAll DownloadAll Delete cave Reload Fig 15 Upload Upload this piece of equation from panel Upload All Upload all equations from panel Download All Download all equations to the panel The equations can be only downloaded together rather than piece by piece Delete Delete the selected equation Save Save all equations to the database Note this operation must be done after defining all equations Reload Restore equation from the last Save operation The numb
3. as shown in Fig 4 Page 2 GstDef M2 2 Defining Tool User s Manual The Intelligent Solution Communication Test Infomation Commucation Result TestCount 2 Successful 0 Failed 2 Timeout Factor Log Communication Detail Index Test Result 0001 0000 Further Information Timeout Timeout 4 1 4 Database Database tools for backup and restoring the database The default folder is Gst software GstUL Backup as shown in Fig 5 Restore Database Cancel Fig 5 4 1 5 Device type Add device types and look at the related symbol as shown in Fig 6 Page 3 GstDef M2 2 Defining Tool qs J E User s Manual The Intelligent Solution Device Pattern 8 Al v d A amp wl x Import Save Save As Down DownAl Upload LUpLoaadAl Default Cancel Qui Mo DeviceTvpeMame Mo DeviceType ame Mo DeviceTypeh ame No DeviceT ype ame No DeviceTypeh ame 1 MULTISENSOR 1 USER DEFINED 1 ZONE VALVE USER DEFINED F P E A 1 1 HEAT DETECTOR USER DEFINED FLO SWITCH USER DEFINED 2 Sounders OPTICAL SMOKE USER DEFINED PRESSURE SWITCH 63 USER DEFINED ALARM ROUTING USER DEFINED USER DEFINED USER DEFINED USER DEFINED Loop Flash Data 2 4 0 0 0 0 0 4 5 2 3 4 2 3 4 5 iz T 8 7 1 2 3 4 5 Bb n B 2 3 4 5 z d 10 1 12 13 14 15 16 1 18 r2 c 2009 03 14 8 26 Fig 6 4 1 6 Cancel Cancel current oper
4. completely deleted 4 2 1 3 Export Devices Right click the name of the panel select Export Devices all the defined devices in this panel can be exported to a text file txt which can be easily converted to Excel file or other format 4 2 1 4 Export Equations This operation can export C amp E equations to a text file by double clicking 4 2 1 5 Upload and Download When a panel is selected the upload or download operation will cover all definitions relating to that panel including zones devices control switches and equations as shown in Fig 9 a v e Upload Download cave FALP Mame i01 GST M 200 FALP Address 1 FACP Type Net Start one lt gt Fig 9 Page 5 GstDef M2 2 Defining Tool qs J ns User s Manual The Intelligent Solution Upload means taking pre record information from the panel Download means sending the definitions to the panel 4 2 1 6 Save The Save operation is for completing definition Each time it will save all changes comparing with previously saved data 4 2 2 Zone Operation Clicking FACP Zone will go to zone operation Here you can add delete or modify the zones 4 3 System Definition 4 3 1 Define zones The protected area can be divided into several zones which in case of emergency situation in a zone a general location information can be shown on the FACP to give people the First Aid The zones should be divided according to building structure A maj
5. 13 GstDef M2 2 Defining Tool qs T a User s Manual The Intelligent Solution T xe SIC GROUND FAULT 39 GROUND FAULT BATTERY CHANGE 40 BATTERY CHANGE AUX 24V FAULT AUX 24V FAULT Page 14 GST China Gulf Security Technology Co Ltd No 80 Changjiang East Road QETDZ Qinhuangdao Hebei P R China 066004 Tel 86 0 335 8502528 Fax 86 0 335 8508942 Email sales gst fs utc com www gst com cn GST UK Global System Technology PLC Lion Court Staunton Harold Hall Melbourne Road Ashby de la Zouch Leicestershire England LE65 1RT Tel 44 1283 225 478 Fax 44 1283 220 690 Email info gst uk com www gst uk com GST Dubai Global System Technology PLC P O Box 17998 Unit ZA04 JEBEL ALI Free Zone Dubai UAE Tel 971 0 4 8833050 Fax 971 0 4 8833053 Email info gst uk com www gst uk com
6. M200 2 there are TWO loops When the panel is created two loops are configured as default 4 3 2 3 Upload and Download oame as for zones the upload or download can be done to one or a group of or all the devices in the current loop 4 3 2 4 Device Check d Click on eck button the software will check the definitions of the current panel As mentioned in Device Number in the whole system the device number cannot be duplicated This operation will check all devices and give the information If there are the same addresses from different loops installed into the same zone the duplicated condition may occur In this case please manually modify the 4 to 6 digits of device Number 4 3 2 5 Reload This operation will restore the definition from last Save operation All modifications not saved will be lost 4 3 3 Define Repeater Panels FACP Net FACP Zone A v FALP Upload Download UploadAll DownloadAll Save Reload on O1_G57T M200 Repeater Number Description ee Equation 3 Loop 00 MetM ade m Repeater O oo w n ony ee Oo Po i c Fig 13 As shown in Fig 13 GST M200 and GST M200 2 can drive up to 10 repeater panels The description 8 characters can be downloaded to the control panel In case there is fault with the repeater panel the description will be displayed on the FACP But even if the repeater panel is not defined it will still work normally 4 3 4 Define Equations
7. Xm se GstDef M2 2 Defining Tool way Issue2 20 September 2011 User s Manual ERP 30308899 GstDef M2 2 Defining Tool User s Manual The Intelligent Solution CONTENTS T C 32 1 MER S SUCTIN PRECIP ING IN acess ua eects cera nc eee eee hexane vee eaten ak eewmwsetetesavaraesoweetatecauaeeae 1 Ze FN OW AN NS 1 Qo SOINS EE saints tide turd tpi tas dari E A AA E TE TE dcus NIA dM NUR INI MES MUN 1 AZ E 1 A Download Card isossa rperonner ie rs IR AE MBE 5 Users C1 0 seen een 2 sx neienireo Ma 2 5 1 1 Com ite gt ec 2 Dee Oe ING INO AGC 2 3 yee Gre 0 1 I 2 SADAT IS O eee ne TER 3 5 1 5 Device type ccccecccccesseeeceesseeceeaseeeceeusececsaseeecseaeeeceuseeessageeeeseageeessauseeesseseeesseaes 3 Dia Os TI MEME A 4 SNNZ oU E M 4 TEO EI iso METTE 4 g2 General ODEA e REN ETT EET 4 S NN Ree Em 4 D22 46 a OPETAN ee ee ee ee ree 6 5 3 System Definition ssctsssaintstniecawaraxasexuatielsps seconesennsorasouesaneceansecenatenasesanedsuedatadatacanecanatenases 6 Gaol DEINE ZONG NONO 6 0 o2 DEME COVIC EE EE EEE 7 5 3 3 Define Control Keys and their LEDS eess Hin REN BA 5 3 4 Define Repeater Panels cccccccssseeeceeseecceseeecee
8. ation It is used to stop downloading or uploading communications 4 1 7 About About the copyright 4 1 8 Exit system 4 2 General Operation The system map provides a quick method to define FACPs loops devices manual keys and zones and etc as shown in Fig 7 FACP Net FACP Zone FACP 9e 01_GST M200 fe Equation Loop O01 NetMade zm Repeater Fig 7 4 2 1 Panel Operation 4 2 1 1 Add New FACP Right click on lt FACP gt click on Add FACP gt The dialogue box is shown in Fig 8 Page 4 GstDef M2 2 Defining Tool qs T Eo User s Manual The Intelligent Solution Fe Add FACP FALP Mame 2 G ST M 200 FACP Addes FACP Type GST M200 Met crcl Fig 8 lt FACP Name Any description of the FACP which can be blank FACP Address The FACP Address must be unique for each control panel lt FACP Type The FACP Type must be correct otherwise GstDef Tools cannot communicate with the panel This setting cannot be changed once it is saved lt Net If lt Net gt is selected the devices in this panel can be used into equations on other panels lt Start Zone The Start Zone is for network use only for GST M200 When the panel is connected to network the information will be displayed on main panel as Zone Local zone Start Zone The setting can be modified later 4 2 1 2 Delete FACP Right click the name of the panel select Delete FACP gt all configurations with this panel will be
9. er of devices both in condition and result shall not exceed 10 If more than 10 devices are to be used please split them into two equations 4 3 4 2 Equations in GST200 and GST200 2 Click the device cell under the Condition Devices the cell becomes editable The device number can be input manually An easier way is double clicking the cell again a defined device list will pop out Choose the device and double click or click OK button the device will be selected and input to the cell as shown in Fig 16 If more than one device are required in the condition click Insert Dev to add another device The relationship between the devices should be manually set means OR logic X means AND logic The operation is the same for adding multiple devices to the result The delay time can be set individually to each output device The delay time is in second multiplied by 10 Maximum 10 minutes 600 seconds For example 6 means delaying 1 minute 6X10 60s Page 9 GstDef M2 2 Defining Tool User s Manual FACP Net FACP Zone FACP QJ 01_GST M200 Fe Equation 3 Loop 001 ES NetNode za Repeater GST The Intelligent Solution P a 4 S 8 New Insert Dev Delete Dev Save Modify Save New Condition Dev Device Device QTY Relation 00100101 0 mma mum rog poe oen o 3 D Device Device Device Device 00101 00100201 00100301 E 0171600 Reload
10. g the current operation Quit Closing the current window 4 3 6 Upload Running Record Right clicking the FACP node at the left of the main screen as in Fig 7 a menu will pop up Choosing History Record the window as in Fig 19 will pop up Page 11 GstDef M2 2 Defining Tool qs T Eo Eel ene The Intelligent Solution History Record No ID EventType Code Device Type Time 2009 09 07 9 06 Fig 19 The user can upload the running record in the FACP to the computer by clicking lt Upload gt After uploading clicking lt Export gt will save the current records in the form of an Excel file the user shall have the Excel program in the computer 5 Caution lt After completing all above definitions please make a backup of the database for future checking and modification lt The copyright of this software is reserved by the manufacturer and protected by law Any copy or modification without the permission of the manufacturer is prohibited lt his operation manual may be updated according to product upgrading without notification Page 12 GstDef M2 2 Defining Tool qs J Eco User s Manual The Intelligent Solution Appendix Device Type List Type ID jActonafterstat OO O OOOO O Undefined 0 Undefined EHE abl 01 02 03 04 05 s L i 5 am ow x2 10 xd FIRE Relay FIRE Relay Trouble Relay Trouble Relay SUPERV Relay SUPERV Relay Page
11. izontal text for some special languages and the screen displays accordingly lt 4 For control panel name of device type is user definable and running record can be uploaded to computer and saved as an Excel file 2 System Requirement 2 1 Hardware CPU Pentium IV 1 7G or above Free Hard disk 2GB or above Memory 1G or above 2 2 Software Windows 7 or Windows XP Professional 3 Installation The software setup file is named GstDef M2 2 setup exe Double clicking the file and following the wizards will install the software into your computer To uninstall the software you can either go to Control Panel Add Remove Software or run the GstDef M2 2 setup exe again Page 1 GstDef M2 2 Defining Tool GS T Eo User s Manual The Intelligent Solution 4 User s Guide 4 1 Function Tools The toolbar is shown in Fig 1 clicking the corresponding button you can reach the relevant window R o z Fd 5 Bot P il Com Set Language Set Com Test Database Device Tvpe Cancel About Exit system Fig 1 4 1 1 Com Set Choose the serial port communicating with control panel as shown in Fig 2 ES Com Set Fig 2 4 1 2 Setting Language Define system language as shown in Fig 3 The software supports multi languages The default language is English The language package can be downloaded from GST website iE Language Set Language Set OF Cancel Fig 3 4 1 3 Com Test Test the communication
12. or consideration is to make people easily access the area By BS standard each detection zone should be no more than 2000m to 3000 m for L1 or L2 The zone definitions are shared by all devices connected to the FACP Each zone may contain devices from different loops and devices from the same loop may be set to different zones Click FACP Zone and select a panel all zones defined in this panel will be displayed And click a zone number you can check all devices in that zone as shown in Fig 10 FACP Net FFACP Zone 38 x amp EXC Zussauuuauauuauauuuuusuuauauuuuuuuyuucur Hew Tel ee Cave Reload n1 GST M200 BackColor Description Zone Dn Zone 1 Zone 002 ni Zone O04 Fig 10 4 3 1 1 Add New Zone B Click New _ there will be a new zone shown at the bottom The information will be shown on panel screen lt ForeColor gt and lt BackColor gt When a device is defined into a zone the text lt ForeColor gt and background lt BackColor gt will easily spot it The default color is black on white as shown in Fig 11 Page 6 GstDef M2 2 Defining Tool rjr User s Manual The Intelligent Solution Address Device Number Loop Zone Device Type Walktest PAS Silenceable Autosilence Location Registered adress 1 5 AE Le ae oe C EOS 6S CH ICE CR CCS 1 E IE 5 cen con IH KN Fig 11 4 3 1 2 Delete zone x Select a zone highlighted and click Dele
13. seeecsesseecseaseeessagseeseseseeesseass 8 Zo DEME EGUNO oes To E 8 CUO e 12 Appendix Device Type LISE ceesexvesserexmieut ene eestor rai vErce tuv evee seat dEravvEE EUMD EIE IUE 13 GstDef M2 2 Defining Tool User s Manual The Intelligent Solution 1 Overview The newly developed GST Intelligent Fire Alarm System Defining Tool software is used for system commissioning It is designed with friendly user interface and powerful functions The fire alarm control panel FACP that can use this software include GST M200 series The main features of this highly intelligent package are lt By dividing control panels into logical zones and with descriptions of each zone the control functions of the panels are made clearer Providing the network definition of up to 32 FACPs of any model of GST M200 series Communicating with FACP through RS232 interface at a rate of 2400bps Devices are distinguished with different icons Zones are easily distinguished with different colors Dropdown lists are used to save time Manual input is also available with memory ability from the software that makes it simpler for similar inputs Definitions can be edited in dialogue boxes lt C amp E equation definition with clear relationship easily selecting exact device or group devices by fuzzy logic lt n addition to normal text display the system also supports upload or download of bi direction text a mixture of left to right and right to left hor
14. te Pelete button 4 3 1 3 Save 3 Press Save _ button to save all the modifications 4 3 1 4 Reload This operation will restore the definition from the last Save operation All modifications not saved will be lost 4 3 2 Define devices 4 3 2 1 General Fig 12 The items include Address The physical address of the device Device Number Each device has a 6 digit number normally arranged as zone number address This number must not be repeated in the whole system including network devices Loop Showing the loop of the devices Zone Dropdown list to select zone Device Type Select device type by dropdown list Type should be selected according to the real device For modules the type is decided by equipment connecting to the module For example there is a Fire Door connecting to a module addressed 17 so address 17 should be defined as 28 FireDoor To view the complete type list please refer to the appendix Walktest PAS lt Silenceable gt lt AutoSlience gt Device properties Location Detailed location of the device maximum 32 characters including letters numbers and some symbols Registered The device is successfully registered or not Page 7 GstDef M2 2 Defining Tool qs J Eco User s Manual The Intelligent Solution 4 3 2 2 Loop Operation For GST M200 there is only ONE loop When the panel is created the loop is configured as default For GST