1. remove old o rings Alte O Ringe entnehmen Removing of old valves 4 Mounting of new valves Entfernen der alten Ventile Einbau der neuen Ventile 1 1 cut off collars of the valves ih use the stem rubber to straight r 0 N Klemmbund der Ventile abschneiden i N the valves 7 N c TT j Ventile mit Hilfe der WEA Einziehhilfe ausrichten i ot N T cai a 0 Nf Ye insert and lock bolt for outlet valve An oul out valves P ME a E Auslassventilschraube einfuegen und b UO Ventile herausziehen l T N festschrauben Vs 3 the stem rubber are to be cut off Einziehhilfen abschneiden loose and remove bolt for outlet valve Auslassventilschraube loesen und entnehmen pull stem rubber and collar through the valve plate 4 Ventilbund durch die Ventilplatte ziehen remove outlet valve insert new outlet valve Auslassventil entnehmen neues Auslassventil einfuegen 5 Mounting of pump chamber Zusammenbau der Foerderkammer 4 lock plastic bolt Kunststoffschrauben einschrauben 3 Lock new diaphragms through pressure plate into clamping ring Neue Mebranen durch Membrangehaeuse deckel in Klemmring schrauben 2 insert valve plate Ventiplatte einlegen A insert new o rings neue O Ringe einlegen For mounting the pump chamber please follow 4 2 Seite 13 von 18 Version of 01 01 2012 a gt ALMATEE L QUATTRO nial Fluid Systems FLOW 4 4 Changing of the shaft bearing cap unit The
2. speed of the motor by the control panel on the top of the pump Main switch Push to start the panel lights up Push to speed up arrow bottom up or to speed down arrow top down Push Green button RUN to start the pump MOD button Switch between rpm effiency motor power V Display show rom V max speed 3 000 rpm Push the Red button STOP to stop the pump Attention The optimal motor parameter are set before the delivery Only authorized and qualified personnel should change the parameter of the control panel Attention You must study the operating instruktions of the PANASONIC Motor before you make any changes of the parameter Quattroflow 150 S Pump Motor Panasonic 50 W 230V with integrated frequence inverter Speed contol Panasonic Digital Control panel Seite 9 von 18 Version of 01 01 2012 o N ALMATEE L QUATTRO i Eua Systems FLOW 3 5 Start U Prior to leaving our factory all pumps are subjected to a leakage and performance test Only properly operating pumps leave the factory achieving the performances assured by us It is possible that there will be a few mls of water inside the pump Prior to each use we recommend to flush the pump with a proper fluid e g water or buffer Prior to the very first use it might make sense to clean and sanitize the pump chamber A commmercial caustic cleaner and or 1n bis 0 5n NaOH can be applied The choosen cleaning agent can be recirculat
3. ball bearings if these are still working smoothly or if these are hard to turn and are noisy during operation Attention Safety hints After purging the pump with air there might be a small residual amout of fluid inside the pump chamber Flush the pump chamber thoroughly and check the rinse fluid Please follow the general guidelines and safety advices when handling with chemicals Disconnect mains supply before opening the pump housing The dismounting and mounting of the pump should be done on a rigid table or work bench Please note the pump is heavy Seite 11 von 18 Version of 01 01 2012 ALMATEE 4 1 Dismounting of the pump chamber Main Switch Hauptschalter Ring drive Control Panel Ringantrieb Fa ae 4 Bediener Panel Pump chamber Foerderkammer Shroud housing stainless steel Edelstahl Haube N A QUATTRO Fuia Systems FLOW Unlock clamping ring and pump chamber Klemmring und Foerderkammer loesen 1 Loose and remove hexagon socket screw plug Verschlussschraube loesen und entfernen Loose bolt of clamping ring inside the housing with an Allen key wrench size 25mm Loesen der Klemmschaube im Pumpengehaeuse mit Innensechskantschluessel 2 5mm Loose bolts Schrauben loesen und entfernen Pull off pump chamber Foerderkammer abnehmen Pull off pump chamber ATTENTION Do not drop Foerderkammer herausziehen ACHTUNG Nicht fallenlassen 4 2 Mounting the pump chamber to the ri
4. pump need to be modified for ATEX applications ALMATEC Maschinenbau GmbH Attention Inadmissible modes of operation arbitrary reconstruction spare parts production and or any changes of the design without admission of the manufacuturer may cancel the liability for the concequences resulting therefrom Seite 7 von 18 Version of 01 01 2012 r oN ALMATEL t QUATTRO R company Fluid Systems FLOW 3 Description of the Quattroflow 150 S pump 3 1 Application and range of utilization of the Quattroflow 150 S pum The Quattroflow 150 S is a 4 piston Diaphragm pump which is mainly used to pump water like fluids that are typically handled in research pilot plant or production facilities of the pharmaceutical biotech food or cosmetic research centers or plants Typical examples of these fluids e Solutions containing proteins albumin IgG Clotting factors monoclonale antibodies enzymes vaccines Solutions of polymers or suspensions silicons latex chromatography media Cell suspensions bacteria yeast algae fungi mammalian cells Colloidale solutions Suspensions of virusses or phages Dairy products Gelatine Supplements and ingredients for cosmetic and food 3 2 Typical process steps in which the Quattroflow 150 S pump is used Filtration technology e To recirculate feed retentate e g membrane cassettes hollow fibre spiral wound ceramic elements e Feed pump for filter cartridges or plate and f
5. valid fort the Quattroflow 150 S pump No liability will be undertaken for any damages caused by non compliance with the operating instructions and service conditions Original spare parts serve safety purposes The use of other parts may cancel the liability for the consequences resulting therefrom Manufacturer ALMATEC Maschinenbau GmbH Carl Friedrich Gauss Str 5 D 47475 Kamp Lintfort Germany Phone 49 2842 961 0 Fax 49 2842 961 40 e mail quattroflow almatec de Internet www quattroflow com 1 2 Labelling of the pump The type label of each Quattroflow pump can be seen on the bottom of the base plate Besides the serial No of the pump head is punshed in at the front cover Quattroflow 150 S with 50W brushless DC motor in a stainless steel housing Power switch Control panel Power kable The type lable on the bottom of the base plate CE sign protection class IP55 Safty lable 6 bar Do not remove Serial No is punched in at the front of the pump Seite 3 von 18 Version of 01 01 2012 r oN ALM ATEE L FQUATTRO COMPANY Flull Systems FLOW 2 Safety These operating instructions contain basic hints to be observed during installation operation and maintenance Therefore prior to mounting and commissioning these operating instructions must by all means be read by the fitter as well as the pertinent expert personnel customer and must always be available at the place of installation of the pump Not on
6. Version of 01 01 2012 N LLM AT EE t FQUATTRO an Fluid Systems FLOW Holland APPLIED TECHNOLOGIES Indianapolis e Chicago e San Juan U ser Man U al www hollandapt com Quattroflow 150 Series 4 Piston Diaphragm Pump These two photographs show the Quattroflow 150 S pump The left one is equipped a stainless steel motor cover and the integrated control panel The right one is the system integrable version of the Quattroflow 150S without a stainless steel motor cover and with a seperate control panel Safety These operating instructions contain advices to be observed during installation operation and maintenance Therefore prior to mounting and commissioning these operating instructions must be read by the user and must always be available at the place of installation Performance Data The exact performance data applying to the pump are to be taken from the order data sheet These Operating and Maintenance instructions contain information from the pump manufacturer They may need to be supplemented by instructions of the operator company for its personnel ALMATEC Maschinenbau GmbH is constantly working on improvements of the pump Modifications of the design or materials might be done without prior notice Seite 1 von 18 Version of 01 01 2012 FN ALMI NEE L QUATTRO 1 General 1 1 1 2 2 gt a T DOVER company F I Ji Appropriate Specification Labelling of the Pump Marking of hints in the oper
7. WLC mit Gewindestange hochhalten Gewindestange entnehmen und 5 u i gt SA A Schraube montieren a Fy ias Seite 14 von 18 Version of 01 01 2012 o N ALMAT EE QUATTRO a DOVER company Fluid Systems FLOW 7 Fit bearing housing Lagerschale montieren Mount bearing housing to the pump L Lageschale aufstecken Insert and lock bolts Schrauben einfuehren und verschrauben For mounting the pump chamber please follow 4 2 Seite 15 von 18 Version of 01 01 2012 r oN ALMI NEE L QUATTRO T DOVER company HUIC FOW 5 Operating troubles causes and remedial action e Operating troubles Causes and remedial action he 4 piston diaphragm pump operates rouble free at any time provided they Are applied according to the operating onditions mentioned in this manual If indought please contact Quattroflow Delivery Pressure oe Motor Display is not ob pay tained obtained delivery noisily warm code Fluid Systems The screws of the pump chamber 1 X X maybe not thightened enough Fixe it 2 X Check the direction of flow showed by the arrow on the pump in case of wrong way turn the pump head 3 X X X Check suction pipeline and TC seals for tightness Check suction head increase suction line cross section Check viscosity of liquid pumped Eine pump speed Control speed of drive motor Check voltage and frequency and the fuse 6 3A T in the controlbox te j AA
8. ating instructions Personnel qualification and personnel training Responsible working Dangers in case of non compliance with the safety hints Safety hints fort the user and or operator Safety hints for maintenance inspection and mounting operations Arbitrary reconstruction and spare part production Attention Warning hints Attention Safety hints 3 Description of the Quattroflow 150 S Pump Application and range of utilization of the Quattroflow 150 S pump Typical application of the Quattroflow 150 S pump Description of the function of the Quattroflow 150 S pump The control panel Start up 4 Maintenance and servicing of the Quattroflow 150 S pump 4 1 4 2 4 3 4 4 Dismounting of the pump chamber Mounting of the pump chamber Changing of the diaphragms and valves Changing of the ball bearing unit shaft ball bearing cap plate 5 Operating troubles causes and remedial actions Pump does not start Pump does not prime Delivery is not obtained Pressure head is not obtained Irregular pump delivery Pump operates noisily Pump is leaky Motor gets to warm Display show error code 6 Performance chart of the Quattroflow 150 S pump 6 1 Diagram 1 Discharge as function of pump rpm 7 Technical data of the Quattroflow 150 S pump Seite 2 von 18 Version of 01 01 2012 N ALMAT EE L QUATTRO a T DOVER company Fluid Systems FLOW 1 General 1 1 Appropriate specification This User Manual is
9. changing of the shaft bearing cap unit can be done by the user Please follow the schematic drawings Dismounting of the pump chamber and Mounting of the pump chamber by using following Spare part kit PSKITWLC155 5 excentric shaft For dismounting the pump chamber please follow 4 1 Remove bearing housing Unlock ii Lagerschale abbauen 2 anced Ka 1 Loose bolt of coupling Loesen der Kupplungsschaube 2 Pull off coupling Kupplung abziehen 3 Loose and remove hexagon socket Screw Schrauben loesen und entfernen pull off bearing housing Lageschale abziehen 1 Loose and remove bolts Schrauben loesen und entfernen Mount new WLC unit lincl excentric shaft Remove WLC unit incl excentric shaft Neue WLC Einheit incl Exzenterwelle einbauen WLC Einheit incl Exzenterwelle entnehmen Spare Part No Ersatzteilnr PSKITWLCISS 1 Use thread rod to straight the WLC unit into the bearing housing U N Mithife einer Gewindestange M5 Fj gan i die WLC Einheit in die Lagerschale Lift WLC unit ify i u NN einfuehren WLC Einheit herausheben Ce Lock WLC into bearing housing 6 Lock coupling and WLC WLC in Lagerschale verschrauben Kupplung und WLC befestigen 2 Lock bolt into bearing retainer fit coupling and lock bolt of coupling 1 ee Kuppl fsteck nd klemm E Schraube in Fixierring schrauben in Dun ie Fil w Fix WLC with thread rod i gt remove thread rod insert and lock bolt OO oes
10. e fluid that will be pumped are to be checked by the operator before the first process run E g Oily fatty fluids or solvents might cause a swelling and or destruction of the elastomeric components If in doubt please contact the manufacturer A Operating the pump in humid or aggressive air can cause damages to the motor and control box A The control box should not be exposed to spray splash water or to heat sources If the Quattroflow 150 S pump is to be used under rough conditions the manufacturer can supply special equipment like motors and controls Seite 6 von 18 Version of 01 01 2012 r oN ALM ATEE L FQUATTRO COMPANY Fluid Systems FLOW 2 10 Attention Safety Hints The following safety hints notify you of the potential of bodily harm or life danger of the user operators A Please read and follow the safety hints and warnings to avoid any risk of bodily harm life danger and or the damage of equipment A Please keep this User Manual available Make sure that the operators of the pump have read and understood the User Manual A training session might be appropriate A We recommend to install specific warning labels at the system Disconnect mains before doing any maintenance The housing of the control box is to be opened only by skilled personnel Check the electrical cables before connecting to mains supply A The Quattroflow 150 S is a positive displacement pump and can theoretically generate an infintely h
11. ed and also stored inside the pump chamber For flushing out of any cleaning agent do not recirculate Check with appropriate analytical methods the success of the flushing procedure Recommendation Test run prior first use Before using your pump in your process e g as recirculation pump in a TFF system perform a test run to get used to the specific properties of the pump Please note ALMATEC Maschinenbau GmbH is also building custom made pumps and set ups These modified pumps can be different from this one that is described in here However the basic information is applicable to all of the Quattroflow 150 S Series pumps Please do not hesitate to contact us for further information ALMATEC Maschinenbau GmbH Carl Friedrich Gauss Str 5 D 47475 Kamp Lintfort Germany Phone 49 2842 961 0 Fax 49 2842 961 40 e mail quattroflow almatec de Internet www quattroflow com Seite 10 von 18 Version of 01 01 2012 r oN ALMATEL t QUATTRO R company Fluid Systems FLOW 4 Maintenance Servicing of the Quattroflow 150 S pump Due to the robust construction the Quattroflow 150 S pump requires only little and easy to do maintenance The ball bearings do not need any extra lubrication The diaphragm and the valves are wear parts These should be checked and if needed be changed once the performance of the pump decreases In case that the diaphragm broke it need to be replaced Then it is also recommended to check the
12. g Stainless steel 1 4435 optional 1 4539 e polished Ra lt 0 4um Ferrite lt 1 m Connector inlet standard other dimetions TC clamp 1 4 Stainless steel 1 4435 are available optional 1 4539 e polished Ra lt 0 4um Flange diameter inlet 25mm internaldiameter inlet mm oS O m Connector outlet standard other dimetions TC clamp 1 4 Stainless steel 1 4435 are available optional 1 4539 e polished Ra lt 0 4um Flange diameter outlet 25 mm Internal diameter outlet mm S O _ Available certificates for stainless steel parts DIN EN 10204 3 1 B Ra Ferrite Flowdirections sd 4 in 90 steps Motor standard Panasonic brushless 50W IP65 Additional cooling fan Not necessary Bsepate Stainless steel 1 4301 e polished Motor housing Stainless steel 1 4301 e polished Dimensions L W H 520K 155xK210mm _ N eee SS Controlbox 1 7 11717 o Z o Frequency inverter _ _ integet o Panel Bedienmodul ESVZXK1 Power supply 230 V 50Hzor115V 60Hz Powercabel appre mm Dimensions L W H 280K 155X185MmM DD __ Weight of the controlbox appr 8kg o o o ooo _____ Germancoustom tarif number 84138190 Seite 18 von 18
13. g of the diaphragm or lines which must be absolutely avoided especially when handling dangerous products Diameter of the suction line need to be sufficient to avoid cavitation The use of a safety device e g pressure switch can be necessary Please make sure that prior to the start of the pump the discharge line is checked Make sure that there is no flow restriction in the discharge line to avoid any over pressure e g closed valve Check all seals e g TC clamps before the pump is started gt BPP The maximum discharge pressure depends on the temperature of the fluid pmax at room temperature 6 barg pmax at 90 C 3barg Please allow the pump to cool down after heat treatment e g CIP SIP Flush the pump prior to use with appropriate fluid e g buffer A Foundation design The foundation must be designed so that it can take the weight of the pump aggregate on the entire surface A Please make sure that the pump is operated with the proper mains voltage and frequeny to avoid damages and electrical danger Due to the versatile possibilities to use the Quattroflow 150 s pump it is highly recommended to check case by case if the Quattroflow 150 S pump will be the right tool for the specific application The user operator is responsible to perform a proper method of testing if the pump should be applied for his specific application The chemical and thermal compatibility of the elastomeric parts of the pump with th
14. i RT rQUAI RO Fluid Systems 250 0 200 0 150 0 0 bar B 2 bar 4 bar gt 6 bar L h 100 0 50 0 0 0 0 500 1000 1500 2000 2500 3000 3500 UpM Caution This flowrates are tested with new diaphragms and valves in the pump It s possible that the pump won t reached this flow rates with used diaphragms and valves In this case it s necessary to change them Look at 4 1 Changing Diaphragms and valves Seite 17 von 18 Version of 01 01 2012 r oN ALMI NEE QUATTRO T DOVER company FLOW 7 Technical data of the Quattroflow 150 S pum 4 piston diaphragm pump LI 1 eonentie hat o Eccentric shaft eg Flowratemax5 app 150 L h atObar DD T CCCC d appr 120W hat Bar Flowratemin5 fap 1lhatObar DD aap at bar Pressure temperature of fluid lt 40 C max P Pressure temperature of fluid gt 40 C max __ Volume of pump chamber without connectors _ appr 15M Surfaces area with contact of fluid ap 73 5cm DEE Residual volume depense on position of ports __ Temperature of fluid 2 CIP 90 C SIP 125 C Autoklav 125 C Speedrange 80 3000rpm Diaphragms EPDM PP compound Santoprene Po Vales ERPOM Po Oringss EPDM Available certificates for elastomer parts FDA 177 2600 USP Class VI m Valve plate Stainless steel 1 4435 optional 1 4539 e polished Ra lt 0 4um Ferrite lt 1 D Pump housin
15. igh pressure even at low speed rpm Prior to each start of the pump check and make sure that the discharge line is not closed or restricted The design of the discharge line must not build up a pressure of gt 6 barg A If suction and or discharge line are flexible tubing then make sure that these tubings do have the proper pressure rating for the full range of temperatures that are applied max 6 bar Do not exceed Warning Label p max bar Do not remove If the maximum pressure is exceeded it can happen that the diaphragm of the pump will burst In this case the fluid will come out of the pump and can cause a danger for the personnel and or enviroment e g caustic cleaner The Quattroflow 150 S pump can pump air which means that most of the fluid inside the pump chamber will be pump out However there will be a residual amount of fluid appr 1 3 ml inside the pump chamber that should be flushed out of the pump before the pump will be opened A Please follow the general safety guidelines when handling chemical fluids wear gloves and or glasses before the pump chamber will be opened A Never operate the pump without coupling and motor housing A The foundation must be designed so that it can take the weight of the pump on the entire surface The Quattroflow 150 S must not be operated in ATEX zones Special versions for ATEX applicationen are available Please contact the manufacturer in case that the Quattroflow 150 S
16. in the liquid to be Check rossurs head open valve in discharge line completely remove obstruction in discharge line Pressure line completely or partly clogged Diaphragm maybe broken Change diaphragm The diameter of the pipes in suction or pressure line are to small Check the coupling halves They must be fixed with at least 2 3mm space ee 5 pins The spider might be worn Beas whether foreign bodies in pump se esse De replace defective parts ESTER nn switch Please alow the motor to cool down please reduce the power consumption I BE ER an Disassemble pump replace the shaft bearing cap unit PSKITWLC123 or PSKITWLC125 emt EEE ER ER 2 a a long time deformed or worn Change Bi or wet the pump Peer en pressure was too high replace it a 2 rey RTT TT TTT Tees Hee housing are defective PSKITQ12 Align coupling accurately 20 The clamping ring screw got loose fixe it See 4 4 Mounting of the pump chamber picture 12 Seite 16 von 18 Version of 01 01 2012 ALMATEE QUATTRO 6 Performance chart of the Quattroflow 150 S pump Performance Diagram Quattroflow 150 S Pump Testmedia Water at ambient temperature Eccentric shaft 3 Discharge pressure 0 to 6 barg 6 1 Diagram 1 Shows appr Flow rates as function of pump rpm Motor is directly coupled to pump Pump rpm motor rom Kennlinie Quattroflow 150 4 N Antrieb Panasonic 50 W Brushless Testmedium Wasser be
17. ly are the general safety hints listed under this item Safety to be observed but also the special safety hints such as for specific use at the user s site 2 1 Marking of hints in the operating instructions The safety hints contained in these operating instructions which in case of non compliance may cause danger to personnel are particularly marked with the danger symbol Safety sign according DIN 4844 W 9 In case of warning against electric voltage with Safety sign according DIN 4844 W8 Safety hints which in case of non compliance may cause danger to the pump itself or to parts of the systems are particularly marked with the word ATTENTION Marking labels at the pump e g Pmax 6bar Direction of flow must not be removed and care have to be taken that these labels are readable 2 2 Safety hints for maintenance inspection mounting and operation The customer shall see to it that all maintenance inspection and mounting operations are performed by authorized and qualified expert personnel who have sufficiently informed themselves by thoroughly studying the operating instructions Basically operations at the machine must be performed during standstill only Pumps handling noxious fluids must be decontaminated 2 3 Responsible working Please follow strictly the safety guidelines that are issued for your particular enviroment Eg the handling of chemicals like caustic or acid the handling of bi
18. ngdrive Mount pump chamber Foerderkammer montieren Straighten pump chamber to the ring drive Clamping ring bolt must be horzintal on top Foerderkammer ausrichten und andrueckenl Klemmringschraube waagerecht oben Lock clamping ring Klemmring klemmen Lock hexagon socket screw plug Verschlussschraube festschrauben Lock bolt of clamping ring inside the housing with an Allen key wrench size 2 5mm Festschrauben der Klemmschaube im Pumpen gehaeuse mit Innensechskantschluessel 2 5mm Tight bolts Schrauben anziehen Seite 12 von 18 Version of 01 01 2012 a gt ALMATEE L QUATTRO a TDOVER company Fluid Systems FLOW 4 2 Mounting of the pump chamber The changing of the diaphragms and valves can be done by the user Please follow the pictures for dismounting and mounting of the pump chamber by using service kit no PSKITQ15 Attention In case of bursting diaphragms by overpressure we advice also to change the shaft bearing cap unit For dismounting the pump chamber please follow 4 1 1 Opening of the pump chamber Daten dar Foardarkammet Dismounting of diaphragms and o rings Herausdrehen der Membranen und O Ringe L Loose and remove bolts i Ai j Schrauben loesen und entfernen a Loose old diaphragms BB Alte Membranen herausschrauben 2 Lift pressure plate incl diaphragms and pe clamping ring a gt Lift lat Membrangehaeusedeckel mit Membranen Ventilplatte else und Klemmring anheben
19. nly Disconnect mains supply before opening the electrical cabinets control box Pumps or aggregates handling noxious fluids e g caustic bio hazardous must be decontaminated Prior to restarting all items and the pump are to be observed 2 Arbitrary reconstruction and spare part construction Reconstruction of or changes to the machine are only admissible after consultation with the manufacturer Original spare parts and accessories authorized by the manufacturer serve safety purposes The use of other parts may cancel the liability for the consequences resulting herefrom 2 8 Inadmissible modes of operation The operating safety of the machine supplied is only ensured with due application according to the operating instructions The limit values given in the data sheet must by no means exceeded Seite 5 von 18 Version of 01 01 2012 r oN ALM ATEE L FQUATTRO COMPANY Fluid Systems FLOW 2 9 Attention Warning hints These warning hints are to prevent the user from an inadmissible mode of operation These warning hints are to be strictly followed to avoid any damage of the pump and or any danger to personnel Diapragm pumps are positive displacement pumps and can theoretically generate an infinitely high pressure With the discharge line closed e g by clogging or by incidental closing of a valve the pressure generated by the pump may reach a multiple of the admissible pressure of the plant This may lead to burstin
20. ological materials the handling of tubing piping instrumentation fittings etc Seite 4 von 18 Version of 01 01 2012 r oN ALM ATEE L FQUATTRO COMPANY Fluid Systems FLOW 2 4 Dangers in case of non compliance with safety hints In case of non compliance with the safety hints may cause danger to personnel equipment and enviroment lt can cause Failure of the proper function of the pump system Danger to personnel by electrical mechanical chemical biological impacts Danger to equipment and enviroment 2 5 Safety hints for the user operator In case of hot parts e g while CIP or SIP protective measures have to be taken Protecting covers of moving parts e g coupling cover of motor must not be removed Leakages of dangerous materials to be handled must be discharged so as not to result in danger to persons or he enviroment Legal stipulations are to be obeserved Dangers by electrical energy are to be excluded for details with regard to hereto please refer to the regulations of the VDE and the local energy supply associations 2 6 Safety hints for maintenance inspection and mounting operations The customer shall see to it that all maintenance inspection and mounting operations are performed by authorized and qualified expert personnel who have informed themselves by thoroughly studying the operating instructions A Basically operations at the machine must be performed during standstill o
21. rame depth filters Chromatography e Packing of chromatography columns e Feed pump to mix gradients e Feed pump for centrifuges or separators e Feed pump for filling machines 3 3 Discription of the working princaple Quattroflow 150 S The Quattroflow 150 S pump is a 4 piston diaphragm pump The 4 diaphragms of the pump oscillate back and forth This alternate movement is created by a connector plate that is arranged on a ball bearing The ball bearing sits on an eccentric shaft The connector plate does not turn The stroke of the pistons is determined by the angle of the eccenter There is only eccentric shafts with 5 available Range of flow rate 5 eccentric shaft appr 1 150 L hr at max 3000rpm Please note The direction of flow can be adjusted by turning the pump chamber in 90 steps The Quattroflow 150 S is self priming and can run dry Inside the pump chamber there are no rotating parts that might cause heating up of the product or shed particles The pump motor unit is mounted on a stainless steel base plate In case that the pump will not be mounted on the base plate but in a frame or any other base measures have to be taken that there will be a proper alignment of the motor and the pump Seite 8 von 18 Version of 01 01 2012 a gt ALMATEE FQUATTRO a DOVER company Fluid Systems FLOW 3 4 The Control panel In the Quattroflow 150 S pump is working a 50 W brushless Panasonic motor You can modify the