Home

MR-1 - User manual

image

Contents

1. Pressing the Stop key for more than 3 s resets the settime If the working time is not set or reset and the display shows 0 00 pressing the Start key will start time indication and will cause the unit to operate non stop until the Stop key is pressed After finishing the work turn the Power switch to the Off position Disconnect the external power supply unit from electric circuit Power Start YW A Stop Reset Fig 1 Control panel 5 Specifications The unit is designed for operation in cold rooms incubators and closed laboratory rooms at ambient temperature from 4 C to 40 C in a non condensing atmosphere and maximum relative humidity 80 for temperatures up to 31 C decreasing linearly to 50 relative humidity at 40 C 5 1 Mixing frequency range eeccceeeeceeeeeeeeeeeeeeneeeseeeeeenneeeneas 5 30 oscill min 52 gt Fixed tilt angle csecsivecucn cited cca ck cecesace ote e ernaar blessed aancedech TaN aeaa Ae 5 3 Digital time S tting s 0 c ssecceeeceeeeecseeceteetaneeeseetensens 1 min 24 hrs non stop 5 4 Maximum continuous operation time eee eneee 168 hrs 5 5 Maximuntloadsscascsaasin nen Giada e a 1 0 kg 56 Platform WOKING EPCS sorserien e aai 200x200 mm 5 7 DIMENSIONS nrnna hada E 220x205x120 mm 5 8 Input current power COnNSUMptiOn eeen 12 V 320 mA 3 8 W 5 9 External power supply input AC 100 240 V 50 60 Hz output DC 12 V 5 10 Weight siinne ANENE NEE
2. from the power socket If liquid penetrates into the unit disconnect it from the external power supply and have it checked by a competent person Do not operate the unit in premises where condensation can form Operating conditions of the unit are defined in the Specifications section DURING OPERATION e Donot impede the platform motion e Do not operate the unit in environments with aggressive or explosive chemical mixtures Please contact manufacturer for possible operation of the unit in specific atmospheres e Do not operate the unit if it is faulty or has been installed incorrectly e Do not use outside laboratory rooms e Donot place a load exceeding the maximum load value mentioned in the Specifications section of this Manual BIOLOGICAL SAFETY e Itis the user s responsibility to carry out appropriate decontamination if hazardous material is spilt on or penetrates into the equipment Page 5 2 General Information MR 1 Mini Rocker Shaker has been upgraded to provide reliable continuous operation Non stop mode up to 7 days and over 2 years of trouble free operation are guaranteed due to of direct drive mechanism and brushless motor Platforms are equipped with non slip thermoresistant silicone mat MR 1 Mini Rocker Shaker provides regulated gentle rocking motion for mixing of samples in vessels placed on the platform Shaker MR 1 provides Soft rocking of the platform with a constant amplitude Smooth regulat
3. local distributor address Please visit www biosan v Technical support section to obtain the claim form The following information will be required in the event that warranty or post warranty service comes necessary Complete the table below and keep a copy for your records Model MR 1 Mini Rocker Shaker Serial number Date of sale Page 10 8 Declaration of Conformity Declaration of Conformity Equipment name MR 1 Type of equipment Mini Rocker Shaker Directive EMC Directive 2004 108 EC Low Voltage Directive 2006 95 EC RoHS 2011 65 EC WEEE 2002 96 EC amp 2012 19 EU Manufacturer SIA BIOSAN Ratsupites 7 build 2 Riga LV 1067 Latvia Applied Standards EN 61326 1 Electrical equipment for measurement control and laboratory use EMC requirements General requirements EN 61010 1 Safety requirements for electrical equipment for measurement control and laboratory use General requirements EN 61010 2 051 Particular requirements for laboratory equipment for mixing and stirring We declare that this product conforms to the requirements of the above Directive s Signature Signature Svetlana Bankovska Aleksandr Shevchik Managing director Engineer of R amp D A a ae __ 12 00 2015 _ _ AF Oe OS Date Version 2 07 January 2015 Page 11 om R m wae wir eee we Bio RS 24 CEB e PST 60HL 4 PST 100HL Applications with heating with hea
4. unit on even horizontal surface remove protective film from display plug the external power supply unit into the 12 V socket at the rear side of the unit Install the platform fitting the pins on the bottom side of the platform into the holes on the moving base Page 7 4 1 4 2 4 3 4 4 4 5 4 6 4 7 4 8 4 9 4 10 4 11 4 12 Page 8 Operation Connect the external power supply unit to electric circuit Place samples on the platform Switch On the Power switch Fig 1 1 the timer display Fig 1 3 will light Using the A and W keys Fig 1 4 set the working time The set time is displayed on the Timer indicator in hours and minutes hh mm Press the Start key Fig 1 2 The platform will start rocking movement and the timer will start counting up the set time interval Timer display shows actual elapsed time until 1 hour in minutes and seconds mmiss after 1 hour in hours and minutes hh mm Set the shaking speed as recommended using the Speed knob Fig 1 6 After the set time interval expires the platform movement will stop and the set working time will be shown on the timer display Press the Start key to repeat operation with the same working time and speed The unit can be stopped before the set time elapses if necessary by pressing the Stop key Fig 1 5 For 20 seconds the time indicator will be showing the time the shaker has worked and after that it will be showing the set time
5. D Medical Biological Research amp Technologies MR 1 Mini Rocker Shaker Operating Manual for version Certificate V 2AW Page 2 Contents Safety Precautions General Information Getting Started Operation Specifications Maintenance Warranty and Claims o NoNaNo Declaration of Conformity Page 3 1 Safety precautions The following symbols mean A Caution Make sure you have fully read and understood the present Manual before using the equipment Please pay special attention to sections marked by this symbol GENERAL SAFETY Use only as specified in the operating manual provided The unit should be saved from shocks or drops The unit must be stored and transported in a horizontal position see package label After transport or storage in humid conditions keep the unit under room temperature for 2 3 hrs before connecting to electric circuit Use only cleaning and decontamination methods recommended by the manufacturer Do not make modifications to the design of the unit ELECTRICAL SAFETY Page 4 Connect only to a power supply with voltage corresponding to that on the serial number label Only use the external power supply unit provided with this product Ensure that the power switch and external power supply are easily accessible during use Disconnect the unit from the electric circuit before moving Turn off the unit by disconnecting the external power supply unit
6. EE R CES EYIN EEE OKEERE O ESSN 2 1kg Accurate within 10 Optional accessory Description Catalogue number PDM Dimpled mat to prevent different size PDM tubes from rolling Replacement parts Description Catalogue number Bio PP 4S Detachable platform with non slip BS 010125 AK thermoresistant silicone mat Biosan is committed to a continuous programme of improvement and reserves the rightto alter design and specifications of the equipment without additional notice Page 9 6 1 6 2 6 3 TA 7 2 7 3 7 4 Maintenance If the unit requires maintenance disconnect it from the mains and contact Biosan or your local Biosan representative All maintenance and repair operations must be performed only by qualified and specially trained personnel Standard ethanol 75 or other cleaning agents recommended for cleaning of laboratory equipment can be used for cleaning and decontamination of the unit Warranty and Claims The Manufacturer guarantees the compliance of the unit with the requirements of Specifications provided the Customer follows the operation storage and transportation instructions The warranted service life of the unit from the date of delivery to the Customer is 24 months Contact your local distributor to check availability of the extended warranty If any manufacturing defects are discovered by the Customer an unsatisfactory equipment claim shall be compiled certified and sent to the
7. ion of the rocking speed Indication and setting of the operating time Automatic stop of platform movement after the set time expires Interruption of the operation at any moment The display of the current operation time MR 1 is an extremely quiet compact shaker that can be easily placed in con fined work spaces The shaker is designed for mixing of samples in Petri dishes plates and tubes MR 1 is ideal for minigel destaining after electrophoresis conducting reactions of northern Southern and western blots washes The device is applicable in all areas of biomedicine biotechnology and micro biology laboratory research Page 6 3 1 3 2 3 3 3 4 Getting started Unpacking Remove packing materials carefully and retain for future shipment or storage of the unit Examine the unit carefully for any damage incurred during transit The warranty does not cover in transit damage Complete set Package contents Standard set MR 1 Mini Rocker Shake finery eta aNG 1 pce Detachable platform Bio PP 4S with silicone Mat 0 ceceeeeeeeeeeees 1 pce DINCONE PAs sseececs iecheaie tied sea Bou cies AT 1 pce External power supply Unit acces disci sistas enireyo N a 1 pce Operating Manual Certificate sssrinin arsu a 1 copy Optional accessory PDMidimpled mat 45 aara cnet a aa Ae on request Standard detachable Bio PP 4S platform with non slip thermoresistant silicone mat Dimplet mat PDM Setup place the
8. ting ES 20 60 ah b with heating PSU 20i Multi RS 60 os arai Bio RS 24 Cell growing ass PF NEW nprs TS DW yi ja P Applications wo es ES Microbiology gt a oe Extraction N PST 60HL s A Cellgrowing NTS X with heating RIG gt PSU 101 Applications EED HA ane _ D lt A Hybridization MSV 3500 PSU 2T ES 20 _ NEW with heating Applications MPS 1 oom A 5 DNA analysis oe ts No hake Genome sequence 4 MR 1 lt 3 Applications ey Agglutination NEW Ly Extraction Multi Bio 3D CvP 2 A a Gel staining _ _ a destaining _ oer aces e a E J x E TS 100 with heating Go gt 4 TS 100C with heating AS Cr and cooling m J a i V 32 MR 12 Applications Agglutination wag gt Extraction e NS Blot hybridisation w Gel staining destaining a amp a gt EMI _ Level of liquid 10 10 ml 10 mi 10 10 ml Erlenmeyer flasks and Cultivation flasks Petri dishes vacutainers and tubes up to 50 ml PCR plates microtest plates and Eppendorf type tubes