1. ProPower foot control Foot control cable o gt A gt amp N Power cord LMProPower Unpacking 1 2 Content of introkit Content of AirLED Polisher introkit 2 x Polisher nozzles universal and angeled 2 x ErgoGrips Light Focus Light 2 x Bottles 180 g polisher powder LM Mi PAA Universal e gt Angeled feel the difference LM Eguipment description 2 Eguipment description 2 1 General description LM ProPower AirLED is an effective AirLED polisher in one versatile and ergonomic appliance The device is eguipped with the impressive LED light that gives an optimal visibility in diagnostics and removal of discolourings and stains Ergonomically designed ErgoGrip handpieces with soft silicone hand les give the user a comfortable relaxed grip as well as an excellent feel 1 Polisher handpiece with an ErgoGrip and a nozzle mounted 2 Handpiece tubing 3 Powder container 4 Water flow control ring 5 Control panel 6 ProPower foot control 7 Medicament bottle 8 Depressurisation button 11 LM Equipment description 1 AC power input 2 Fuse holder Polisher 3 Air hose coupling Model LM ProPower 100722 Type No 5609661
2. 11 2 1 OCHE Al OSCAR a en 11 2 2 CONO 12 2 3 ProPower foot control iii 13 2 4 Medicament bottle aa 14 2 5 Symbols on the equipment annan anasti 15 5 MSO aac 16 3 1 General installation instructions onneen 16 3 2 Version for tap water i 17 3 3 General installation instructions continued 17 4 Operating instructions u mannaa nannaa 18 4 1 General Leoni 18 5 Cleaning and maintenance u 11111111111112 a 21 5 1 General cleaning procedure 21 5 2 Recommended cleaning procedure 22 5 3 MAINTENANCE ANA PADAPA ANA AA 23 6 IFOUDICSNODOTNG iaia 24 Fr Technical gata a 25 8 Warranty and Declaration of conformity 27 GeL Vuan AY AA 27 8 2 Declaration of conformity ssi 28 09 EMG GUIDANCE AA maser 29 LM LM iie Safety Safety Intended use This AirLED polisher unit is designed for dental purposes It is designed for removal of plague cleaning discoloured teeth and other dental work where air polishing is beneficial The unit should only be used by licensed dental proffesionals trained in the proper use of polis hing devices Do not use it for applications where it is not intended If you are unsure about your application please contact your local dealer or place of purchase General reguirements Installation an
3. dentine sur faces root cement and com posite fillings N 2 The polisher air purges the handpiece for a few seconds 3 After the cleaning cycle is finished remove the nozzle by pulling it vainen out from the handpiece It is important to air purge 4 Wash the nozzle in an ultrasonic bath 40 50 C for at least 3 minu AA KN NE treatment to prevent clogg tes before cleaning sterilization If ultrasonic cleaning not is possible ing flush the nozzle in warm water 5 Sgueeze the ErgoGrip gently at the top and at the same time slide it off the handpiece Do not squeeze too hard at the ErgoGrip as this can pe ie one Hin Se make the removal difficult e Pence A sher nozzle mounted in the 6 Remove the powder container and polisher handpiece handpiece 7 Before removing the medicament bottle press the depressurization button Banal paran o not leave powder in the 8 Pullthe medicament bottle from the unit powder nine over ie 9 Clean and sterilize the equipment components according to the night 20 Cleaning and maintenance section on page 21 23 LM Cleaning and maintenance 5 Cleaning and maintenance Note Always set the water flow to fully open before running the cleaning cycle dots in line see picture N Caution The automatic cleaning function must always be performed with the polisher nozzle mounted in the hand piece 5 1 General cleaning procedures Air purg
4. ou le patient au risque lectrique e Utilisez l original empaquetage en renvoyant le mat riel pour le service Avertissement Le produit ne doit pas tre utilis a proximit ou empil avec d autres 6guipements Si l usage adjacent ou empil est necessaire le produit doit tre surveill pour une utilisation normale suivant la configuration dans laquelle il sera utilis Consigne de securite Notifications de surete en ce manuel N Warning indique une situation proba blement dangereuse La inobservance peut mener a la mort ou des dommages WARNING Caution mdigue une situation probable ment nocive La inobservance peut endom mager le materiel Caution Note decrit si on observe la notification speciale Note LM feel the difference LM aie Unpacking 1 Unpacking Carefully unpack your LM ProPower AirLED unit and verify that all accessories and components are included according to the content lists below Note 1 1 General content of delivery This chapter describes the components of the delivery and can be used as a check list when unpacking Con tact your place of purchase If anything is missing For a description of the features of the equipment read the Equipment description sec tion on page 11 LM ProPower AirLED unit Polisher introkit see section 1 2 500 ml medicament bottle or water hose 1 4 Air hose Powder container Polisher handpiece and tubing
5. LM LMProPower AIrLED difference om A J N Jan USER MANUAL LM This manual is valid for LM ProPower 100722 LM ProPower 100732 LM ProPower 100722us LM ProPower 100732us LM ProPower 100722jp LM ProPower 100732jp Important Read this manual carefully before using the product How to read this manual Fach chapter starts with a section with general instructions which is followed by sections with additional information First read the general section and then proceed to the section that applies to your product If there are any questions regarding the contents of this manual please contact LM Instruments Oy Manufacturer Marketing and Sales LM Instruments Oy PL 88 Norrbyn rantatie 8 FI 21601 Parainen Finland Telephone 358 2 4546 400 Fax 358 2 4546 444 E mail info amp lminstruments com Internet www lminstruments com Copyright Copyright 2010 LM Instruments Oy All rights reserved The contents of this manual may be changed without notice No part of this manual may be reproduced in any form or by any means without permission in writing from LM Instruments Oy Printed in Sweden January 2010 C 0537 LM iee Contents Sd 5 Consignes de securite Canada 111 1 7 I MEV AG IN lla 9 1 1 General content of delivery XQ Xa 9 1 2 Content of MALL GA 10 2 Equipment description a nana nanna
6. Serial NG XXXXX 3 S 4 Water hose coupling optional 5 Foot control connection 6 Type plate gt 2 230 VAC 50 60 Hz 40 VA T 10W 24 28 kHz Foot cbntrol lt E O o N AIR 4 10 bar 2 2 Control panel ag _ lt a mun 1 1 Cleaning key 2 Power on key 3 Power off key 4 Air Purge key 5 Working mode 2 key 60 power 6 Working mode 3 key 60 or 100 power 7 StandBy indicator 8 Power on indicator 9 Air Blow mode indicator polisher 10 Water Jet mode indicator polisher 11 Air Purge indicator 12 Working mode 2 indicator 13 Working mode 3 indicator 14 Cleaning mode indicator 12 LM Equipment description 2 3 ProPower foot control SN N Connection for foot control cable OFF position ON position Diagnostic function turn LED light ON or OFF by a single click on the pedal Water Jet position 6 Working mode 3 position if working mode 3 is chosen on control board otherwise working mode 2 Working mode 2 position 13 Equipment description 2 4 Medicament bottle optional LM ProPower has a medicament dispenser system making the device independent of a fixed water supply connection The medicament bottle can be used for either medi cament solutions or ordinary clean water The unit contains an electrically driven air compressor When operating the unit the compressed air forces the fluid from the bo
7. d service of the product is only to be performed by authorized service personnel The product must be connected to electricity water and compressed air supply meeting the requirements specified in the Technical data section on page 25 The product needs special precautions regarding EMC Elektro Magnetic Compability and needs to be installed and put into service according to the EMC information provided on page 29 Portable and mobile RF Radio Freguency communications eguip ment can affect the product General precautions e If the handpiece tubing is damaged or worn out it must immedia tely be replaced to avoid exposing the user or the patient to elec tric hazard e Use the original packaging when returning equipment for service Warnings The product should not be used adjacent to or stacked with other eguipment If adjacent or stacked use is necessary the product should be observ ed to verify normal operation in the configuration in which it will be used Safety Safety notices in this manual N Warning indicates a potentially dange rous situation Non observance may lead to MARNA death or injury N Caution indicates a potentially harmful situation Non observance may damage Giusi the equipment Note indicates a situation where special notice should be observed Note LM feel the difference LM Consigne de securite Consigne de securite Canada Utilisation prevue Cet apparei
8. d should be provided N WARNING Polishing should NOT be performed on patients who e Are on a sodium restricted diet Have renal insuffiency e Have chronic respiratory disease e Are on long term steroid or diuretic therapy N WARNING Especially when using a sodium bicarbonate cleaning powder the spray 2 The jet should be kept constantly moving in small circles It should not houd never De deciso be directed at the same spot too long The nozzle shall be held approx into the gingival sulcus or imately 3 mm 0 12 in from the surface onto the gingival margin as 3 The polisher will be most effective when directing the jet downright this can result in unneces towards the tooth although the spray should be directed away from the Che no W h h val tissues and or extension gingiva onto the tooth of the periodontal pocketing 4 Only one or two teeth should be polished at a time with frequent with associated clinical com rinsing performed An efficient intraoral evacuation system will prevent excessive build up of fluid and increase patient comfort A short learning period is required by the operator as with any new technique until the ideal angulations soft tissue protection and an effective treatment can be achieved After treatment i Without removing the nozzle place the polisher handpiece over the bowl and press the air purge key AP plications Caution should be exercised in dealing with
9. de 3 100 Working mode 1 can not be activated N Caution It is very important to air purge the polisher hand piece after each treatment to prevent clogging 10 11 12 13 14 15 16 Operating instructions Gently slide the ErgoGrip on to the polisher handpiece lt Poo MAA Insert the polisher nozzle into the handpiece until the bottom Turn on the polisher on by pressing the button marked ON on the front side of the scaler The blue polisher indicator lamp illuminates Choose working mode 2 or 3 by pressing the corresponding working mode key on the keyboard see note A second press of the ON key activates the Air blow mode for cleaning with just air A third press of the ON key activates the Water Jet cleaning mode No powder but only water and air comes out from the nozzle The Water Jet mode can also be activated in the scaling mode by pres sing down the foot control in the leftmost position By pressing the ON key repeatedly it will toggle between normal polishing Air blow and Water Jet mode Point the handpiece towards the cuspidor and over the bowl Depress the foot switch to activate the polisher and adjust the water flow with the ring on the powder container see equipment description Hold the polisher nozzle approximately 1 cm 0 4 in downright from the bottom of the bowl and press the foot control to activate the polisher Slowly reduce the water flow
10. e equipment into the domestic refuse Please use the re turn and collection systems available in your country for the disposal of this product The equipment can also be returned to the manufacturer for disposal 15 Installation 3 Installation 3 1 General installation instructions Checklist e Position the unit horizontally with the handpieces in the holders and the hoses hanging free e Position the unit where air is free to circulate on all sides and be neath it Do not position the unit on a wall or next to a heat source e Avoid placing the unit in the immediate vicinity of sources of electromagnetic radiation for example an electrosurgery equip ment e Connect the foot control cable to the foot control and at the rear side of the unit Connecting to the air supply 1 Verify that the air supply can be turned off 2 Verity that the air pressure con forms to the data in the Technical data section on page 25 3 Use only dry and filtered com pres sed air 4 Unscrew the nut from the nipple and thread it on the hose 5 Push the hose onto the coupling nipple al 6 Tighten the nut firmly and ensure that the hose 1s securely attached to the unit 7 Connect the other end of the hose to the air supply LM N Caution Do not place the unit on or next to a heat source Ex cessive heat may damage the electronics N Caution Consult a qualified technici an for connecting th
11. e guick cleaning function With the polisher mode active a press on the AP button will air purge the handpiece for a few seconds Air purge the handpiece after each treatment to prevent clogging Automatic cleaning function 1 Place the polisher handpiece over the bowl and start the cleaning cycle by pressing the cleaning key C 2 The cleaning cycle starts and stops automatically after 80 seconds Cleaning of the eguipment components Wipe off with a soft cloth and use a 45 isopropanol and detergent solution Cover and control panel Polisher handpiece tubings and cables Cap for powder container Wash at max 65 C 149 F Powder container Medicament bottle Cap for medicament bottle 21 LM Cleaning and maintenance Autoclave in steam at max 135 C 275 F or wash at max 95 C 203 F Polisher nozzle Note Always set the water flow to fully open before running the cleaning cycle dots in line see picture LM ErgoGrip LED LM ErgoGrip Focus LED 5 2 Recommended cleaning procedure Beginning of the day Run the automatic cleaning cycle with clean water See instructions N on page 21 Caution After each treatment Do not sterilize any acces e To prevent clogging air purge the polisher handpiece after each sories using dry heat or treatment See instructions on page 20 chemical autoclaves This may damage the material Do not immerse on page 21 the handpiece
12. e unit to the air supply Use only dry and filtered compressed air LM Installation 3 2 Version for tap water optional Connecting to the water supply 1 Verify that the water supply can be turned off 2 Verify that the water pressure conforms to the data in the Technical N data section on page 25 3 Verify that the water supply fulfills the medical demands of Caution hygiene Consult a gualified technici 4 Unscrew the nut from the nipple and thread it on the hose an for connecting the scaler 5 AA Push the hose onto the coupling nipple 6 Tighten the nut firmly and insure that the hose is securely attached to the unit 7 Connect the other end of the hose to the water supply 3 3 General installation instructions continued e Verify that the voltage rating on the rear side match the voltage of the AC power outlet N e Verify that the AC power outlet is provided with a protective ground WARNING e Connect the power cord to the unit and the AC power outlet POC UNIE GS De Connie All indicator lamps will illuminate for a short period during a ted to an AC power outlet provided with a protective self check of the unit ground USA and Canada The power cord and plug must be classified as Hos pital Grade The unit is standby when the green indicator lamp is illuminated 17 LM Operating instructions 4 Operating instructions Preparations bot
13. eck that the o rings on the polisher nozzle into the handpiece are lubricated and in good condition If problems cannot be resolved according to this troubleshooting guide please contact your dealer for further service support 24 LM Technical data 7 Technical data LM Instruments Oy Manufacturer PL 88 Norrbyn rantatie 8 FI 21601 Parainen FINLAND EN60601 1 Class 1 Type B 93 42 EU Medical products class Ila 270 x 110 x 165 mm without bottle and powder container 100 Vac 50 60 Hz Voltage 115 Vac 50 60 Hz 230 Vac 50 60 Hz T500 mAH 250 V 05x20 mm 100 Vac Primary fuse T400 mAH 250 V 05x20 mm 115 Vac T200 mAH 250 V 05x20 mm 230 Vac Separate with protective earth plug Transport and storage 40 C to 70 C 40 F to 158 F Operation 10 C to 40 C 50 F to 104 F Transport and storage 10 to 100 Ambient temperature Relative humidity Operation 10 to 95 VIP pressi 1 10 bar 0 1 1 0 MPa 14 5 145 PSI version conn to tap water Bottle volume bottle version o PERE ALA 4 10 bar 0 4 1 0 MPa 58 145 PSI PPY P Use only dry and filtered compressed air Powder container capacity 45 g Installation and service of the product is only to be performed by authorized service personnel by the manufacturer N ON Technical data Medicaments that can be used e Clean water e Cetylpyridinium chloride e Clorhexidine e Essential oils e H
14. ency range applies NOTE2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people Field strengths from fixed transmitters such as base stations fro radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the LM ProPower is used exceeds the applicable RF compliance level above the LM ProPower should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as reorienting or relocating the LM ProPower Over the freguency range 150 kHz to 80 MHz field strengths should be less than 3 V m L M ue Warranty and declaration Recommended separation distances between portable and mobile RF communications equipment and the LM ProPower The LM ProPower is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the equipment can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the LM ProPower as recommended below according to the maximu
15. ervice or repair is performed by persons not authorized by the manufacturer Normal wear and tear is specifically excluded from this Limited Warranty Manufacturer disclaims any express warranty not provided herein and any implied warranty guarantee or representation as to suitability for any par ticular purpose performance guality and absence of hidden defects and any remedy for breach of contract which but for this provision might arise by implication operation of law custom of trade or course of deal ing including implied warranties of merchantability and fitness for a par ticular purpose except as provided in this limited warranty The manufacturer further disclaims any responsibility for losses expenses inconveniences special indirect secondary or conseguential damages arising from ownership or use of the product 27 Warranty and declaration 8 2 Declaration of conformity The manufacturer hereby declares that the LM ProPower AirLED unit Class I type B according to EN60601 1 equipped with original acces sories conforms to the essential requirements of the Medical Device Directive 93 42 EEC with reference to the following harmonized standards IEC 60601 1 Third edition 2005 EN 60601 1 2006 Classification Medical products Class Ila C 0537 28 LM N WARNING No modification of this eguipment is allowed feel the difference LM ace Warranty and declaration 8 3 EMC Gu
16. frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment 29 Warranty and declaration LM dice Guidance and manufacturer s declaration electromagnetic immunity The LM ProPower is intended for use in the electromagnetic environment specified below The customer or the user of the LM ProPower should assure that it is used in such an environment Immunity test IEC 60601 test level Men Electromagnetic environment guidance 30 Portable and mobile RF communications equipment should be used no closer to any part of the LM ProPower including cables than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Recommended separation distance Conducted RF 3 Vrms d 1 2VP IEC 61000 4 6 150 kHz to 80 MHz Radiated RF 3 V m d 1 2VP 80 MHz to 800 MHz IEC 61000 4 3 80 MHz to 2 5 GHz d 2 3VP 800 MHz to 2 5 GHZ were P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer and d is the recommended separation distance in metres m Field strengths from fixed RF transmitters as deter mined by an electromagnetic site survey should be less than the compliance level in each frequency range Interference may occur in the vicinity of equipment marked with the following symbol O NOTE 1 At80 MHz and 800 MHz the higher frequ
17. idance and manufacturer s declaration Guidance and manufacturer s declaration electromagnetic emissions The LM ProPower is intended for use in the electromagnetic environment specified below The customer or the user of the LM ProPower should assure that it is used in such an environment Emissiontest Compliance Electromagnetic environment guidance The LM ProPower uses RF energy only for its internal function Therefore it s RF emissions are very low and are not likely to cause any interference in nearby electronic eguipment RF emissions CISPR 11 RF emissions CISPR 11 The LM ProPower is suitable for use in all establishments including domestic establishments and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes Harmonic emissions Notanolicabie IEC 61000 3 2 PP Voltage fluctuations flicker emissions Not applicable IEC 61000 3 3 Guidance and manufacturer s declaration electromagnetic immunity The LM ProPower is intended for use in the electromagnetic environment specified below The customer or the user of the LM ProPower should assure that it is used in such an environment i IEC 60601 Electromagnetic environment Immunity test Compliance level test level guidance Electrostatic discharge ESD IEC 61000 4 2 Electrical fast transient burst IEC 61000 4 4 Surge IEC 61000 4 5 Voltage dips short interruptions a
18. in any fluid e Wipe off the cover control panel handpiece and the hose with a soft cloth Use a 45 isopropanol and detergent solution e Wash the nozzle in an ultrasonic bath 40 50 C for at least 3 minutes before cleaning sterilization If ultrasonic cleaning not is possible flush the nozzle in warm water e Wash the ErgoGrip the nozzle and autoclave according to the clinic s routines e Runthe automatic cleaning cycle with clean water See instructions End of the day e Runthe automatic cleaning cycle with clean water See instructions on page 21 e Remove and wash medicament bottle bottle cap and powder container at a maximum temperature of 65 C 149 F e Wipe of the powder container cap with a soft cloth Use a 45 isopropanol and detergent solution 22 LM N Caution A petroleum based lubricant on the o rings may shorten their durability time Cleaning and maintenance Weekly bottle version e Run the automatic cleaning cycle with an anti microbial cleaning agent solution in the bottle for example Planosil See instructions on page 21 We recommend to use a separate bottle for the cleaning agent solution Concerning exposure times of cleaning agent follow instructions given by manufacturer e Before patient treatment to rinse the lines from cleaning agent solution put clean water in the bottle and run the automatic cleaning cycle until clean water comes out of the handpiece 5 3 Ma
19. intenance Power cord Inspect the power cord cables and the handpiece hose daily to insure that the eguipment is in g00d condition without mechanical damage O rings bottle and powder container connectors polisher nozzle Lubricate the O rings regularly with a glycerine based water soluble lubricant Vaseline may also be used but it may shorten the durability time of the O rings Exchanging fuses 1 Disconnect the power cord from the AC power outlet and the unit 2 Open the fuse holder on the rear side of the unit 3 Inspect the fuses for damages Replace damaged fuses with new ones Verify the fuse specifications according to the Technical data section on page 25 4 Close the fuse holder 23 LM Troubleshooting 6 Troubleshooting 6 1 General Problem Action The green Stand by indicator lamp is off Check that the power cord is connected pro perly Check the fuses and replace 1f necessary For further instruction read the Exchanging fuses section on page 23 The blue power ON indicator 1s flashing Check that the foot control cable 1s connected in both ends and is not defective There is a stop in the polisher nozzle and Place the nozzle in an ultrasonic bath with no air and powder is coming out from the WARM water for a couple of minutes Flush nozzle the nozzle in water and dry it with compressed alr reconnect and try again It is difficult to insert the polisher nozzle Ch
20. l a ropolisseur Air LED est destin des applications dentaires Il est concu pour liminer le plaque biofim des taches et decolorations des dents et pour toute autre application dentaire ou l a ropolissage est b n fique Cet appareil doit tre exclusivement manipul par des professionnels dentaires dipl m s ayant suivi une formation relative l utilisation correcte des dispositifs de d tartra ge N employez pas cet appareil pour des applications pour lesquelles il n est pas con u Au cas o vous ne seriez pas s r de son application veuillez contacter votre distributeur local ou le point de vente Conditions g n rales L installation et le service du produit doit tre execute seulement par le personnel de service autoris avec les outils et le mat riel appro pri s Le produit doit tre reli a l approvisionnement de l lectricit et l approvisionnement en eau et en air comprim r pondant aux exigences d finies dans la section Caract ristiques techniques la page 25 Le produit exige des pr cautions sp ciales concernant la CEM Compatibilit Electromagn tique et doit tre install et mis en service selon la page 29 L quipement de communication RF Radio Fr quence portable et mobile peut affecter le produit Pr cautions g n rales e Si la tuyauterie de pi ce a main est endommag e ou us e elle doit imm diatement tre substitu e pour viter d exposer l utilisateur
21. m output power of the communications equipment Separation distance according to frequency of transmitter m Rated maximum output power of 150 kHz to 80 MHZ 80 MHz to 800 MHz 800 MHz to 2 5 GHz transmitter d 1 2VP d 1 2VP d 2 3VP For transmitters rated at a maximum output power not listed above the recommended separation distance d in metres m can be estimated using the equation applicable to the frequency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer NOTE 1 At 80 MHz and 800 MHz the separation distance for the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people 31 32 LM feel the difference LM feel the difference 33 34 LM feel the difference LM feel the difference 35 LM Instruments Oy PL 88 Norrbyn rantatie 8 F1 21601 Parainen Finland Tel 358 2 4546 400 Fax 358 2 4546 444 info lminstruments com www Iminstruments com
22. nd voltage varaiations on power supply input lines IEC 61000 4 11 Power frequency 50 60 Hz magnetic field IEC 61000 4 8 6 kV contact 8 kV air 2 kV for power supply lines 1 kV for input output lines 1 kV differential mode 2 kV common mode lt 5 Yo Ur gt 95 dip in Ur for 0 5 cycle 40 Yo U 60 dip in Ur for 5 cycles 70 Ur 30 Yo dip in Ur for 25 cycles lt 5 U gt 95 dip in U7 for 5 sec 6 kV contact 8 kV air 2 kV for power supply lines 1 kV for input output lines 1 kV differential mode 2 kV common mode lt 5 Ur gt 95 dip in Ur for 0 5 cycle 40 Yo U 60 dip in Ur for 5 cycles 70 Ur 30 dip in Ur for 25 cycles lt 5 U gt 95 dip in U7 for 5 sec NOTE Uj is the a c mains voltage prior to application of the test level Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at least 30 Mains power quality should be that of a typical commercial or hospital environment Mains power quality should be that of a typical commercial or hospital environment Mains power quality should be that of a typical commercial or hospital environment If the user of the LM ProPower requires continued operation during power mains i interruption it is recommended that the LM ProPower be powered from an uninterruptible power supply or battery Power
23. tle version 1 Fill the medicament bottle with water or medicament solution according to the Medicaments that can be used section on page 25 2 Screw the bottle connector onto the bottle and push it onto the con nector See picture in section 2 4 3 Check that the unit is connected to air supply the power cord is con nected and the unit is in stand by mode the green indicator lamp is illuminated 4 1 General 1 Unscrew the powder container from the cap and fill the powder container with LM ProPower powder up to MAX Note Only use original LM ProPower air polishing powder n 2 Screw the container back on to the cap and connect the tubing N to the cap Caution It is Important that the pow g 00 der container is fully tighte SV ned before the polisher is activated Do not leave powder in the Namn powder container over the night 3 Connect the powder container cap to the connectors on the right side of the unit 4 Connect the medicament bottle to the unit see instruction section 2 4 bottle version feel the difference LM IN Caution It is very important that the polisher not is activated be fore the nozzle is mounted A WARNING When inserting the nozzle it is important to push it in until the bottom is reached Note For the polisher only work ing mode 2 and 3 can be activated Working mode 2 is aprox 60 of polishing power compared to working mo
24. ttle through the hose and to the handpiece and the tip nozzle 1 Medicament bottle 2 Bottle connector 3 Depressurisation button The LM ProPower can be delivered either with the medicament dispenser system or with fixed water supply connection without the bottle and bottle connector 14 LM feel the difference LM gt O A lt FF Polisher Model LM ProPower 100732 Type Na 568971 Scnal No XXAXX S M harmana Oy PL 06 iha 3yr marie di 121621 PARSINEN CLASSIFIED M A LG C 0537 x PO gt Eguipment description 2 5 Symbols on the eguipment Air Purge Working mode 2 60 power Working mode 3 60 or 100 power Water Jet mode Air Blow mode Automatic cleaning function Power ON Power OFF Example of type plate The type plate is placed on the back side of the scaler unit Medical electrical eguipment classified by ETL with respect to electric shock fire mechanical and other specified hazards in accordance with the Safety Standards ANSI AAMI ES 60601 1 and CAN CSA C22 2 No 60601 1 08 Caution Consult accompanying documents Compliance label indicating compliance with the Medical Device Directive 93 42 EEC 0537 is the ID number of the Notified Body VTT Withstands autoclave temperature 135 C 275 F Type B applied part according to the degree of protection against electrical shock Fuse Input Output Please do not throw th
25. until the powder starts to accumulate on the surface as a white spot Increase the water flow until the spot just disappears The air polisher is now balanced for optimum performance 9 Perform polishing treatment according to How to use the polisher section on next page Water Jet cleaning With the foot control pressed down in the leftmost position the Water jet cleaning mode is activated and no powder but only water and air comes out from the nozzle 19 feel the difference LM Operating instructions Polishing power With working mode 3 choosen and the foot control is pressed down in the rightmost position the unit will temporarely switch to working mode 2 the polishing power is reduced to aprox 60 Air purge guick cleaning function With the polisher mode active a press on the AP button will air purge the handpiece for a few seconds Air purge the handpiece after each treat ment to prevent clogging How to use the AirLED polisher Polishing is suitable for the following procedures Efficient removal of heavy stains and dental plaque Cleaning teeth prior to bleaching Cleaning pits and fissures prior to sealant placement Surface cleaning prior to any acid etch or bonding procedure Cleaning orthodontically banded or bracketed teeth Cleaning of implants Protective eyewear should be worn by the patient and operator Contact lenses should not be worn or a close fitting eye shiel
26. ydrogen peroxide 3 USP e Povidine iodine 10 solution e Saline solution e Sangurinara extract e Planosil Oxygenal and Dentosept for unit cleaning e Sodium hypochlorite 1 solution 26 LM N WARNING Immedately after using any kind of medicament in the medicament bottle run the automatic cleaning cycle with clean water in the medi cament bottle until clean water comes out of the handpieces LM feel the difference Warranty and declaration 8 Warranty and Declaration of conformity 8 1 Warranty The manufacturer hereby warrants that the unit will be free from defects arising from faulty materials or workmanship for a period of twentyfour 24 months from the date of purchase by a customer from an authorized dealer Limited Warranty This Limited Warranty 1s limited to free of charge repair or replacement of any defective parts by the authorized dealer or distributor from whom the unit was purchased by the customer This Limited Warranty applies only 1f the unit is installed and used by the customer according to the instruction furnished herein is connected to a proper power supply is not misused or abused and there is no evidence of tempering mishandling neglect accidental or wilful damage or modifications The customer must contact the authorized dealer from whom the unit was purchased to request repair or replacement under this Limited Warranty This Limited Warranty is void if s
Download Pdf Manuals
Related Search
Related Contents
Sun Fire X2200 M2 Server Service Manual Ferm Tile Cutter FTC-400 インラインサーモユニットキット(ラバーホース用)取扱説明書 PLANA ELÉTRICA DE 3¼" (82MM) MANUAL DE INSTRUÇÕES Cat BM2 24H 4Z/GP Operating Instructions Press to ClickCartPro v 5 - Kryptronic Central Server Samsung SyncMaster Fellowes e500 User's Manual Copyright © All rights reserved.