Contents
1. it is highly recommended that you choose a longer wake up interval to save battery life If the device ID 0 is selected as the target device for the wakeup notification the periodic wake up is suppressed It is possible to specify the device number 255 as the destination device for the wake up notification In this case the message is sent as a broadcast to all devices with direct wireless connection The advantage of immediate notification is offset by the disadvantage that where appropriate the device consumes more time in active mode and thus more battery capacity Meaning of LED signals Confirmation green 2 seconds Error red 2 seconds Confirmation of each keystroke green 1 4 second Waiting for selecting the network mode green flash Waiting for selection of group in association mode green flashes quickly Waiting for node information frame in association mode green red without blinking NUBWN FE Technical specifications Protection class IP 20 Battery type 1 x CR2032 Z Wave frequency 868 42 MHz SRD Band Wireless range Up to 100 m outdoors Up to 20 m in buildings on average Disposal information This device contains batteries Please refer to the applicable disposal regulations for batteries It is an electrical device It can be disposed of free of charge at specified disposal sites EC Declaration of Conformity Hereby Schwaiger GmbH declares that the product ZHSO3 is in compliance with
2. power it is thus usually in deep sleep mode In deep sleep mode the device cannot received any wireless signals Therefore a static controller is required which is mains powered and therefore always available for wireless data transmission This controller for example an IP gateway manages a message mailbox for this battery powered device in which messages to the unit can be temporary stored Without such a static controller using this battery pow ered device will quickly discharge the battery or render use completely impossible This device regularly wakes up reports this by sending a so called wake up notification and then empties its mailbox in the static controller The node ID of the controller and a wake up interval must be defined with the inclusion If the inclusion is carried out by means of a static controller such as an IP gateway this controller will automatically perform this configuration and usually offer a user interface to adapt the wake up interval to user needs The wake up interval is a compromise between maximum battery life and minimum response time of the battery powered device Immediately after the inclusion the device remains awake about 2 5 seconds so that a controller can perform configuration tasks The device can then always be woken manually For this the manage ment mode is activated keep all four buttons pressed for 5 seconds and then press button 2 The minimum wake up interval is 240 seconds However
3. ZHS03 WIRELESS DUAL PADDLE WALL SWITCH BDA_ZHS03_b QJ USER MANUAL ZHSO3 Congratulations and thank you for purchasing the Schwaiger ZHSO3 pro duct Below you will find useful operating guidelines Product description Not only can both Z Wave devices be controlled directly with the Z Wave Me wireless wall switch but in an IP gateway different scenes can be activated Although the wireless wall switch controls devices directly it cannot as Z Wave controller manage their networks but always requires an additional con troller for inclusion and exclusion The device can operate in different modes which are determined by configuration parameters iR Control groups of other Z Wave devices with ON OFF and dimming commands 2 Control of devices in the vicinity of the fob with ALL ON or ALL OFF commands 3 Activation of pre defined scenes in gateways or other Z Wave devices Installation guidelines The device is delivered in working condition with a built in battery In this default condition simply pressing on one of the buttons since the device is not included in a network and therefore unable to send a message will result in an error code flashing red LED In this manner the operational readiness of the device can be tested The device can be mounted on every level and dry sur face either with screws or double sided tape First the base plate is secured to the wall In the next step the switching eleme
4. azardous substances and must not be disposed of with household waste Battery type 1 x CR2032 Performance of the device in the Z Wave network When delivered the device is not connected to a Z Wave network It must be integrated into a Z Wave network so that it can communicate with other Z Wave devices This process is called Z Wave inclu sion Devices can also be removed from networks again This process is called Z Wave exclusion Both processes are started from a controller that must be connected to an inclusion and or exclusion mode The manual of the controller contains information on how it is to be connected in these modes Devices can only be added when the controller of the Z Wave network is in inclusion mode Leaving the network through exclusion will reset this device to its factory defaults Bring your Z Wave controller in the inclusion mode Bring your wireless wall switch in management mode and press button 3 The device is included and or excluded locally by pressing key 3 in man agement mode In order to include and or exclude the device network wide button 1 in management mode must be pressed Operation of the device Depending on the mode and further configuration the device can be set differently Standard mode Controlling a group with 2 buttons This is the default setting One group no 1 of the equipment is controlled with buttons 1 and 3 the other group no 2 is controlled with buttons 2 and 4 Buttons 1 and 2 switc
5. h the actuators ON buttons 3 and 4 switch the actuators OFF If double click the setting parameters 1 or 2 is activated groups 3 and 4 can be controlled by means of short double clicking Dimming of devices is enabled through pressing the buttons for a long time high dimming with buttons 1 and 2 low dimming with buttons 3 and 4 and or a short click and pressing for groups with a double click A single click controls groups 1 and 3 A double click controls groups 2 and 4 Group 1 2 Group 3 4 ON ON LED Batterie Group 1 2 Group 3 4 OFF OFF Controlling a group with a button in this mode the groups are controlled by a respective button Pressing a button switches ON double clicking a button switches OFF High dimming of devices is achieved by holding the button down for a long time and low dimming is achieved by clicking and holding the button The group number corresponds to the button number Controls Controls group 1 group 2 O LED Batterie Controls Controls group 3 group 4 Control commands The configuration parameters 11 to 14 regulate which commands are sent when the buttons are pressed Direct control of devices occurs through ON OFF HIGH DIMMING and DOWN DIMMING The special commands ALL ON and ALL OFF send a group call to all devices in direct wireless range The devices react according to their settings to the command switch everything This m
6. ivate scenes in IP gateways but can also be used to activate predefined scenes in other devices Switches Switches group 1 group 2 O LED Batterie Switches Switches group 3 group 4 Advanced scene control In this mode pressing any key will trigger a scene command with a set number The scene number is a combination of the group number and the defined button press action It always consists of two digits The group number determines the first digit the action determines the second digit The fol lowing actions are possible high dimming stop low dimming stop Example clicking double clicking button 1 sends an activation signal for scene 11 single clicking process and scene 12 double off controlling a group with a button is selected This mode includes the communication setting 6 Child protection The device has a child protection mechanism Local operation by using buttons is blocked and only wireless operation is possible The device can be set to child lock mode In this mode no local control is possible The child lock mode can only be activated wirelessly Only in protection mode with input mode it is possible to disable protection by pressing any button for 5 seconds Only in protection mode with input mode it is possible to disable protection by pressing any button for 5 seconds The protec tion is activated again after 5 seconds Communication with a battery powered device The device is battery powered and to save
7. nt is secured to the frame The electron ics module is used to fix the frame to the base plate as shown in the figure Finally the rocker switches are mounted on the electronics module For a battery change the rocker switches must be re moved The CR battery can be replaced by pressing the small locking tab above the battery Logging in inclusion or logging out exclusion of the sensor The device operates in normal control mode or in man agement mode Pushing all four buttons for 5 sec will turn the device into management mode indicated by blinking green LED The management mode will time out after 10 seconds if no further button is pushed Button 1 confirms standard inclusion or exclusion started by a primary controller button 2 issues a Node Information Frame or wakeup notification button 4 is used to add devices into association groups and button 1 confirms inclusion or exclusion in NWI network wide inclusion mode The device distinguishes between two operating modes standard and management mode Standard mode In this mode the wireless wall switch can control other devices or activate scenes Management mode The device is switched to management mode when all four buttons are held down together for at least 5 seconds A slow flashing green LED confirms the management mode In management mode the buttons have other functions Without further button operation the unit will return to standard mode in 10 second
8. ode includes the communication setting 7 Simple scene control with configurable scene commands Devices in association groups are individually configured with the Z Wave command class scene controller configuration A scene can be configured via an association group As can be seen in the figure the number of the scene is by default equal to the number of association group This mode is always used by default to activate scenes in IP gateways but can also be used to activate predefined scenes in other devices Switches Switches group 1 group 2 O LED Batterie Switches Switches group 3 group 4 Control commands The configuration parameters 11 to 14 regulate which commands are sent when the buttons are pressed Direct control of devices occurs through ON OFF HIGH DIMMING and DOWN DIMMING The special commands ALL ON and ALL OFF send a group call to all devices in direct wireless range The devices react according to their settings to the command Switch everything This mode includes the communication setting 7 Simple scene control with configurable scene commands Devices in association groups are individually configured with the Z Wave command class Scene controller configuration A scene can be configured via an association group As can be seen in the figure the number of the scene is by default equal to the number of association group This mode is always used by default to act
9. s Each operation also ends the management mode In management mode the following actions can be performed Confirm Node information network frame wide Wake up inclusion Information O LED Batterie Confirm Start normal inclu association sion mode SCHWAIGER HOME AUTOMATION MANUFACTURER INFORMATION Dear Customer should you require technical advice retailer could not help please technical support and your contact our Schwaiger GmbH W rzburger Stra e 17 90579 Langenzenn Hotline 49 0 9101 702 199 www schwaiger de info schwaiger de Business hours Monday to Thursday Friday 08 00 17 00 08 00 14 30 Button 1 Network wide inclusion the device can be added to a Z Wave network from anywhere in the network This requires a primary controller that supports explorer frames This mode lasts 20 seconds and stops automatically Touching any key also stops the mode Button 2 Sends node information frame and wake up messages as outlined in the following chapters Button 3 Standard inclusion exclusion mode the device is directed by a controller of direct wireless range Touching any button stops the mode An exclusion of the device from a network resets the device to its factory defaults Button 4 Set associations to assign target devices to one of the 4 association groups Batteries This device is battery operated Use only batteries of the specified type Used batteries contain h
10. the essential require ments and other relevant provisions of Directive 1999 5 EC The Declaration of Conformity can be found at the following address http www schwaiger de downloads
Download Pdf Manuals
Related Search
Related Contents
Canon VB-S30D Installation Guide Rust-Oleum Specialty 210372 Use and Care Manual CA Enterprise Log Manager - Manuel d 009.14 - EDITAL - Itens e especificações (ANEXO X) Epson EB-G6050W Manuale di installazione e configurazione rapida NetBotz Package Insert - Sekisui Diagnostics Philips myLiving Spot light 56242/31/16 1 Utilice Copyright © All rights reserved.