Foundation FieldBUS Linking Device
Contents
1. e the Fieldbus Solutions for Rockwell Automation s Integrated Architecture User Manual publication 1757 UM006 for a condensed overview of fieldbus wiring considerations Publication 1757 INO21E EN P August 2009 12 Foundation Fieldbus Linking Device Ethernet Connection If you connect or disconnect the communication cable with power applied to this module or any device on the network an electrical arc can occur This A could cause an explosion in hazardous location installations Be sure that power is removed or the area is nonhazardous before proceeding Connect your Ethernet cable to the Ethernet port on the underside of the linking device The factory default for the linking device is Dynamic Host Configuration Protocol DHCP for initial configuration H1 Terminal Block WARNING When you connect or disconnect the removable terminal block RTB with field side power applied an electrical arc can occur This could cause an A explosion in hazardous location installations Be sure that power is removed or the area is nonhazardous before proceeding Be careful when stripping wires Wire fragments that fall into the linking device could cause damage The H1 terminal plugs are keyed so they fit only into the corresponding socket Be certain that you are connecting the cables to the correct plugs The linking device provides two parallel terminals on each H1 network Use one to connect to your fieldb
2. United States Please contact your local Rockwell Automation representative for any technical support issues New Product Satisfaction Return Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures United States Contact your distributor You must provide a Customer Support case number call the phone number above to obtain one to your distributor to complete the return process Outside United States Please contact your local Rockwell Automation representative for the return procedure Allen Bradley Rockwell Automation ControlLogix RSLogix 5000 RSLinx Classic Logix5000 Rockwell Software PLC 5 ProcessLogix RSFieldbus RSLinx and TechConnect are trademarks of Rockwell Automation Inc Trademarks not belonging to Rockwell Automation are property of their respective companies www rockwellautomation com Power Control and Information Solutions Headquarters Americas Rockwell Automation 1201 South Second Street Milwaukee WI 3204 2496 USA Tel 1 414 382 2000 Fax 1 414 382 4444 Europe Middle East Africa Rockwell Automation Vorstlaan Boulevard du Souverain 36 1170 Brussels Belgium Tel 32 2 663 0600 Fax 32 2 663 0640 Publication 1757 IN021E EN P August 2009 PN 45236 Supersedes Publication 1757 IN021D EN P October 2005 Copyright
3. the EDS file The EDS file can also be downloaded from http www ab com networks eds html and installed with the RSLinx EDS Hardware Installation tool Publication 1757 INO21E EN P August 2009 Foundation Fieldbus Linking Device 17 Set the Linking Devices Network Parameters 1 Open RSLinx software and click the RSWho icon 2 Browse to the linking device under the Ethernet IP driver 3 Right click the linking device and choose Module Configuration to set network parameters 1757 FFLD Ver 2 1 25 Configuration General Port Configuration Device Name IF Vendor Product Type Product Code Revision Serial Number D003614F Publication 1757 IN021E EN P August 2009 18 Foundation Fieldbus Linking Device 4 Click the Port Configuration tab to view or change parameters 1757 FFLD Ver 2 1 25 Configuration General Port Configuration Network Configuration Type Static C Dynamic e IP Address Network Mask Gateway Address Primary Name Server Secondary Name Server Domain Name Host Name AB_FFLD M Auto negotiate port speed and duplex Current Port Speed Current Duplex Changes to Port Speed and Duplex require module reset Status Network Interface Configured Carce Asov 5 When you finish making changes click Apply and then OK Troubleshoot the Linking Device The following instructions describe how to maintain your linking d
4. the linking device to a panel by using 8 or M4 screws tightened to 1 1 1 8 Nem 10 16 Ibein All dimensions are in mm in 168 lt 6 62 DIN Rail Center Line 132 Yi 122 Biip i me A a 15 78 43580 31991 M Publication 1757 IN021E EN P August 2009 Foundation Fieldbus Linking Device 11 Wire the Linking Device Wire your linking device by using these instructions WARNING e If you connect or disconnect wiring while the field side power is on an electrical arc can occur This could cause an explosion in hazardous A location installations Be sure that power is removed or the area is nonhazardous before proceeding e When you change switch settings while power is on an electrical arc can occur This could cause an explosion in hazardous location installations Be sure that power is removed or the area is nonhazardous before proceeding Wire Requirements The FOUNDATION Fieldbus recommendation for the cable connecting fieldbus devices is 0 8 mm 18 AWG shielded twisted pair wire It is important to calculate how the planned topology for your fieldbus segment selected wiring supplied power and intended mix of fieldbus devices may impact the overall performance of a fieldbus network For further details see e the FOUNDATION Fieldbus specifications at http www fieldbus org publication AG 140
5. 2009 Rockwell Automation Inc All rights reserved Printed in the U S A
6. 57 INO21E EN P August 2009 24 Foundation Fieldbus Linking Device 1757 FFLD2 1757 FFLD4 Environmental Specifications Attribute Value Radiated RF immunity 1V m with 1 kHz sine wave 80 AM from 2000 2700 MHz IEC 61000 4 3 10V m with 1 kHz sine wave 80 AM from 80 2000 MHz 10V m with 200 Hz 50 Pulse 100 AM at 900 MHz and 1890 MHz EFT B immunity 2 KV at 5 kHz on power ports IEC 61000 4 4 2 KV at 5 kHz on shielded Fieldbus ports 2 KV at 5 kHz on Ethernet ports Surge transient immunity 2 KV line earth CM on shielded Fieldbus IEC 61000 4 5 a 2 kV line earth CM on shielded Ethernet ports Conducted RF immunity 10V rms with 1 kHz sine wave 80 AM from 150 kHz 80 MHz on power ports PAS shielded Fieldbus ports and Ethernet ports Magnetic field immunity 30 A m long duration at 50 Hz IEC 61000 4 8 1757 FFLD2 1757 FFLD4 Certifications Certification 2 Value c UL us UL Listed for Class I Division 2 Group A B C D Hazardous Locations certified for U S and Canada See UL File E194810 Publication 1757 INO21E EN P August 2009 Foundation Fieldbus Linking Device 25 1757 FFLD2 1757 FFLD4 Certifications Certification 2 Value CE European Union 2004 108 EC EMC Directive compliant with e EN 61326 1 Meas Control Lab ndustrial Requirements e EN 61000 6 2 Industrial Immunity e EN 61000 6 4 Industrial Emissions e EN 61131 2 Programmable Cont
7. EC temp code T4 n circuit battery life 5000 charge discharge cycles about 13 years Battery is not replaceable Enclosure type rating None open style Each network defined as a FOUNDATION Fieldbus 31 25 kbps H1 network Use this Conductor Category information for planning conductor routing Refer to Industrial Automation Wiring and Grounding Guidelines publication 1770 4 1 Publication 1757 INO21E EN P August 2009 Foundation Fieldbus Linking Device 23 1757 FFLD2 1757 FFLD4 Environmental Specifications Attribute Opera IEC 60068 2 1 Test Ad Operating Cold IEC 60068 2 2 Test Bd Operating Dry Heat IEC 60068 2 14 Test Nb Operating Thermal Shock ing temperature Value 0 60 C 32 140 F Nonoperating temperature IEC 60068 2 1 Test Ab Unpackaged Nonoperating Cold IEC 60068 2 2 Test Bb Unpackaged Nonoperating Dry Heat IEC 60068 2 14 Test Na Unpackaged Thermal Shock 40 85 C 40 185 F Relative humidity IEC 60068 2 30 Test Db Unpackaged Damp Heat 5 95 noncondensing Vibration IEC 60068 2 6 Test Fc Operating 5g 10 500 Hz Operating shock 15g IEC 60068 2 27 Test Ea Unpackaged Shock Nonoperating shock 30g IEC 60068 2 27 Test Ea Unpackaged Shock Emissions Group 1 Class A CISPR 11 ESD immunity 6 kV contact discharges IEC 61000 4 2 8 kV air discharges Publication 17
8. Installation Instructions Foundation Fieldbus Linking Device Catalog Numbers 1757 FFLD2 1757 FFLD4 Topic Page Important User Information 2 Environment and Enclosure 3 North American Hazardous Location Approval 4 European Hazardous Location Approval 5 Parts Illustration of the Fieldbus Linking Device 6 Install the Linking Device 7 Wire the Linking Device 11 Configure the Linking Device 14 Troubleshoot the Linking Device 18 Specifications 21 Additional Resouces st 2 About the Fieldbus Linking Device The FOUNDATION Fieldbus Linking Device bridges from the Ethernet network to H1 networks It accepts either High speed Ethernet HSE or EtherNet IP messages and converts them to the H1 protocol By supporting H1 HSE and EtherNet IP protocols the linking device is capable of providing bridging capability of Rockwell Automation products and FOUNDATION Fieldbus products on the Ethernet network to products on H1 links ALLEN BRADLEY Rockwell Roceweit Sorrwae Automation 2 Foundation Fieldbus Linking Device Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment Safety Guidelines for the Application Installation and Maintenance of Solid State Controls Publication SGI 1 1 available from your local Rockwell Automation sales office or online at http Awww literature rockwellautomation com describes
9. ail mounting dimensions ATTENTION A Thi s product is grounded through the DIN rail to chassis ground Use zinc plated yellow chromate steel DIN rail to assure proper grounding The use of other DIN rail materials for example aluminum or plastic that can corrode 0X idize or are poor conductors can result in improper or intermittent grounding Secure DIN rail to the mounting surface approximately every 20 0 mm 7 8 in and use end anchors appropriately Do these steps o install your linking device on the DIN rail 1 Verify that the placement of the linking device on the DIN rail allows for 50 mm 2 in of space on all sides for adequate ventilation 2 Hook the top slot over the DIN rail Publication 1757 IN021E EN P August 2009 Foundation Fieldbus Linking Device 9 3 While pressing the linking device down against the top of the rail snap the bottom of the linking device into position AA Y Middle of DIN 43482 Dimension Height A 138 mm 5 43 in B 69 mm 2 715 in C 69 mm 2 715 in DIN latch closed 76 1 mm 3 in DIN latch open Mount on a Panel Follow these steps to install your linking device on a panel 1 Verify that the placement of the linking device allows for 50 mm 2 in of space on all sides for adequate ventilation Publication 1757 INO21E EN P August 2009 10 Foundation Fieldbus Linking Device 2 Use the following figures to mount
10. and understanding of the product ATTENTION dentifies information about practices or circumstances that can lead to personal injury or death property damage or economic loss Attentions help you identify a hazard avoid a hazard and recognize the consequences SHOCK HAZARD Labels may be on or inside the equipment for example drive or motor to alert people that dangerous voltage may be present BURN HAZARD Sos Labels may be on or inside the equipment for example drive or motor to alert people that surfaces may reach dangerous temperatures PEPE eie Publication 1757 INO21E EN P August 2009 Foundation Fieldbus Linking Device 3 Environment and Enclosure This equipment is intended for use in a Pollution Degree 2 industrial environment in overvoltage Category Il applications as defined in IEC A 60664 1 at altitudes up to 2000 m 6562 ft without derating This equipment is considered Group 1 Class A industrial equipment according to IEC CISPR 11 Without appropriate precautions there may be difficulties with electromagnetic compatibility in residential and other environments due to conducted and radiated disturbances This equipment is supplied as open type equipment It must be mounted within an enclosure that is suitably designed for those specific environmental conditions that will be present and appropriately designed to prevent personal injury resulting from accessibility t
11. evice Reset the Linking Device You can reset the linking device with the reset jumper locally e reset button locally e web page remotely To use the reset jumper or reset button follow the procedures below To use the web page refer to the FOUNDATION Fieldbus Linking Device User Manual publication 1757 UM010 You can reset the linking device to the following defaults Reset Configuration e Factory Publication 1757 INO21E EN P August 2009 Foundation Fieldbus Linking Device 19 Reset Configuration The Reset Configuration removes power from the battery clearing all downloaded fieldbus configurations The linking device retains its network configuration and web page password information through this reset Do these steps to reset configuration 1 Remove power from the linking device If you insert or remove the jumper while the power is on an electrical arc can occur This could cause an explosion in hazardous location installations Be sure the area is nonhazardous before proceeding 2 Move the jumper from its original position two right pins to the two left pins 3 Wait 5 seconds 4 Move the jumper back to its original position 5 Return power to the linking device Reset to Factory Default The factory default reset sets the linking device s network configuration to use BOOTP erases web page password information and clears all downloaded fieldbus configurations Follow these ste
12. linking device Number of fieldbus devices per H1 network max 16 8 10 recommended Number of fieldbus devices per linking device max 64 Power requirements Current rating supply power In rush current 300 mA 24V DC 20 1 5A Isolation voltage 50V continuous Basic Insulation Type Fieldbus to system backplane and Ethernet network to system backplane Type tested at 500V AC for 60 s Panel mounting screw torque using M4 or 8 screws 1 1 1 8 Nem 10 16 Ibein Publication 1757 INO21E EN P August 2009 22 Foundation Fieldbus Linking Device 1757 FFLD2 1757 FFLD4 Technical Specifications Attribute Wiring category Value 2 on Fieldbus ports 3 on power ports 2 on Ethernet ports Terminal block torque specifications 0 34 Nem 3 Ibein on power and Fieldbus wire connections Wire size DC power connection Fieldbus connections Ethernet connections 0 2 1 5 mm 26 16 AWG solid or stranded copper wire rated at 75 C 167 F or greater 1 2 mm 3 64 in insulation max 0 8 mm 18 AWG solid or stranded shielded twisted pair copper wire rated at 75 C 167 F or greater 1 2 mm 3 64 in insulation max RJ45 connector according to IEC 60603 7 2 or 4 pair Category 5e minimum cable according to TIA 568 B 1 or Category 5 cable according to ISO IEC 24702 Program retention unpowered 21 days North American temp code T4
13. linking device including function block and web page details Fieldbus Solutions for Rockwell Automation s Integrated Architecture User Manual publication 1757 UM006 Publication 1757 INO21E EN P August 2009 Overview of intergrating fieldbus into ProcessLogix ControlLogix and PLC 5 controllers Foundation Fieldbus Linking Device 27 Notes Publication 1757 INO21E EN P August 2009 Rockwell Automation Support Rockwell Automation provides technical information on the Web to assist you in using its products At http wwwsupport rockwellautomation com you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make the best use of these tools For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation representative or visit http www support tockwellautomation com Installation Assistance If you experience a problem within the first 24 hours of installation please review the information that s contained in this manual You can also contact a special Customer Support number for initial help in getting your product up and running United States 1 440 646 3434 Monday Friday 8 a m 5 p m EST Outside
14. network patameters for your linking device Assign an IP Address The Rockwell Automation BOOTP DHCP Server BOOTP is a standalone program that combines the functionality of standard BOOTP software with DHCP software The linking device is shipped with DHCP enabled To configure the linking device by using BOOTP perform the following steps 1 Choose Start gt Programs gt Rockwell Software gt BOOTP DHCP Server 2 3 2 Standalone gt BOOTP DHCP Setver 2 3 2 Standalone BOOTP opens and the linking device sends a request Sa BOOTP DHCP Server 2 3 EE Fie Tools Help Request History Clear History hrmin sec Type Ethemet Address MAC IP Address Hostname 13 27 30 DHCP O0 00 BC 26 22C1 Relation List New Doi Ethemet Address MAC Type IP Address Hostname _ Description Status Entries Unable to service DHCP request from 00 00 BC 26 22 C1 O of 256 2 Verify that the linking device is the correct device by matching the MAC address with the MAC address found on the label of the linking device under the barcode Publication 1757 INO21E EN P August 2009 Foundation Fieldbus Linking Device 15 3 Double click the request New Entry dialog box opens Ethemet Address MAC 00 00 BC 26 22 C1 IP Address RCE Hostname Description 4 Type the IP address for the linking device New Entry Ethemet Address MAC O1 IP Address Hostname Descri
15. ns on the following pages Mount the Linking Device Most applications require installation in an industrial enclosure Pollution Degree 2 to reduce the effects of electrical interference Over Voltage Category ID and environmental exposure Locate your linking device as far as possible from power lines load lines and other sources of electrical noise such as hard contact switches relays and AC motor drives For more information on proper grounding guidelines see the Industrial Automation Wiring and Grounding Guidelines publication 1770 4 1 e We do not recommend vertical mounting due to heat build up considerations e Be careful of metal chips when drilling mounting holes for your linking device or other equipment within the enclosure or panel Drilled fragments that fall into the unit could cause damage Publication 1757 INO21E EN P August 2009 8 Foundation Fieldbus Linking Device Product Dimensions Dimension Measurement Height A 138 mm 5 43 in Width B 168 mm 6 62 in Depth C 87 mm 3 43 in Mount on a DIN Rail The linking device DIN rail latch locks in the open position so that the linking device can be easily attached to or removed from the DIN rail The maximum extension of the latch is 15 mm 0 67 in in the open position You need a screwdriver to remove the linking device The linking device can be mounted to 35 x 7 5 or 35 x 15 DIN trails EN 50 022 See page 10 for DIN r
16. o live parts The enclosure must have suitable flame retardant properties to prevent or minimize the spread of flame complying with a flame spread rating of 5VA V2 V1 VO or equivalent if non metallic The interior of the enclosure must be accessible only by the use of a tool Subsequent sections of this publication may contain additional information regarding specific enclosure type ratings that are required to comply with certain product safety certifications In addition to this publication see e Industrial Automation Wiring and Grounding Guidelines for additional installation requirements Allen Bradley publication 1770 4 1 e NEMA Standards 250 and IEC 60529 as applicable for explanations of the degrees of protection provided by different types of enclosure To comply with the CE Low Voltage Directive LVD all connections to this equipment must be powered from a source compliant with safety extra low A voltage SELV or protected extra low voltage PELV To comply with UL restrictions all connections to this equipment must be powered from a source compliant with Class 2 or limited voltage current Publication 1757 INO21E EN P August 2009 4 Foundation Fieldbus Linking Device North American Hazardous Location Approval The following information applies when operating this equipment in hazardous locations Products marked CL I DIV 2 GP A B C D are suitable for use in Class Division 2 Gr
17. ouch connectors or pins on component boards Do not touch circuit components inside the equipment Use a static safe workstation if available Store the equipment in appropriate static safe packaging when not in use Publication 1757 INO21E EN P August 2009 6 Foundation Fieldbus Linking Device Parts Illustration of the Fieldbus Linking Device The sample illustration shows the parts that comprise the 1757 FFLD linking device which links Rockwell Automation products and FOUNDATION Fieldbus products on the Ethernet network to products on H1 links Feature 31989 M Description Reset configuration jumper Factory default reset button inside top cover Interface to expansion 1 0 removable ESD sticker H1 status indicators Status indicators Fieldbus H1 interface terminals Filler module Power supply connection not shown oj CO NM MD oy BY wy N Ethernet port not shown Oo Serial port not used Publication 1757 INO21E EN P August 2009 Foundation Fieldbus Linking Device 7 Before You Begin The following software is compatible with this revision of the linking device e RSFieldbus software version 2 03 or later e RSLogix 5000 programming software version 16 03 or later e RSLinx Classic software version 2 52 or later e Logix5000 Clock Update tool Install the Linking Device Install your linking device by using the instructio
18. oups A B C D Hazardous Locations and nonhazardous locations only Each product is supplied with markings on the rating nameplate indicating the hazardous location temperature code When combining products within a system the most adverse temperature code lowest T number may be used to help determine the overall temperature code of the system Combinations of equipment in your system are subject to investigation by the local Authority Having Jurisdiction at the time of installation Informations sur l utilisation de cet quipement en environnements dangereux Les produits marqu s CL 1 DIV 2 GP A B C D ne conviennent qu une utilisation en environnements de Classe Division 2 Groupes A B C D dangereux et non dangereux Chaque produit est livr avec des marquages sur sa plaque d identification qui indiquent le code de temp rature pour les environnements dangereux Lorsque plusieurs produits sont combin s dans un syst me le code de temp rature le plus d favorable code de temp rature le plus faible peut tre utilis pour d terminer le code de temp rature global du syst me Les combinaisons d quipements dans le syst me sont sujettes inspection par les autorit s locales qualifi es au moment de l installation EXPLOSION HAZARD e Do not disconnect equipment unless power has been removed or the area is known to be nonhazardous Do not disconnect connections to this equipment unless power has been
19. ps to complete a factory default reset 1 Verify that the linking device is powered up and in a running state H1 status indicators are blinking 2 Press the reset button When you press the reset button while power is on an electrical arc can occur This could cause an explosion in hazardous location installations Be sure that power is removed or the area is nonhazardous before proceeding Publication 1757 INO21E EN P August 2009 20 Foundation Fieldbus Linking Device Status Indicators Linking Device Status Indicators Indicator Status H1 Off Description The linking device H1 channel is inactive Verify that the linking device is connected to the H1 network Flashing green The linking device H1 channel is active STATUS Off module No power Module does not have 24V DC power Verify that power is supplied to the module Flashing green Standby Module not config red Green Operational Module operating correctly Flashing red Minor fault A recoverable fault has been detected Verify that the configuration is correct and consistent Red Major fault An unrecoverable fault has been detected Recycle power to the module If this does not clear the fault replace the module WDOG 0 ormal operation watchdog Flashing red _ Software fault Contact Rockwell Automation Technical Support BATT 0 ormal operation battery Flashing red Jumper i
20. ption 5 Click OK The device is added to the Relation List at the bottom of the BOOTP DHCP Server window Relation List New peice Ethernet Address MAC 00 00 80 26 22 C1 Type DHCP 192168 1 67 Entries 1 of 256 Staus Sent 192 168 1 67 to Ethemet address 00 00 BC 26 22 C1 To permanently assign this configuration to the linking device select the device and click Disable BOOTP DHCP When you cycle power to the linking device it uses the configuration you assigned and does not issue a DHOP request Publication 1757 IN021E EN P August 2009 16 Foundation Fieldbus Linking Device 7 To enable DHCP for the linking device select the device and click Enable DHCP Save the Relation List You can save the Relation List for later use Do these steps to save the Relation List 1 From the File menu choose Save As The Save dialog box opens 2 Choose the location to save in 3 Type a File name for the Relation List for example Control System Configuration and click Save Install the EDS File The EDS file can be uploaded directly from the linking device This feature lets you register the EDS file for your device from within RSLinx software by following the steps listed below 1 Open RSLinx software and browse for the linking device 2 Right click the linking device and choose Upload EDS file from the device 3 Complete the EDS wizard to register
21. removed or the area is known to be nonhazardous Secure any external connections that mate to sl this equipment by using screws iding latches threaded connectors or other means provided with this product ubstitution of components may mpair suitability for Class Division 2 e f this product contains batteries they must only be changed in an area known to be nonhazardous e ERZ Publication 1757 IN021E EN P August 2009 RISQUE D EXPLOSION e Couper le courant ou s assurer que l environnement est class non dangereux avant de d brancher l quipement e Couper le courant ou s assurer que l environnement est class non dangereux avant de d brancher les connecteurs Fixer tous les connecteurs externes reli s cet quipement l aide de vis loquets coulissants connecteurs filet s ou autres moyens fournis avec ce produit La substitution de composants peut rendre cet quipement inadapt une utilisation en environnement de Classe Division 2 e S assurer que l environnement est class non dangereux avant de changer les piles Foundation Fieldbus Linking Device 5 European Hazardous Location Approval European Zone 2 Certification The following applies when the product bears the Ex or EEx marking This equipment is intended for use in potentially explosive atmospheres as defined by European Union Directive 94 9 EC Intertek certifies that this equipment has been fo
22. rollers Clause 8 Zone A amp B C Tick Australian Radiocommunications Act compliant with AS NZS CISPR 11 Industrial Emissions Ex European Union 94 9 EC ATEX Directive compliant with EN 60079 15 Potentially Explosive Atmospheres Protection n e EN 60079 0 General Requirements 13 GExnAnLiic EtherNet IP ODVA conformance tested to EtherNet IP specifications FF FOUNDATION Fieldbus Test Campaigns H1 CT0060 HTK 000900 1 When product is marked 2 See the Product Certification link at http www ab com for Declarations of Conformity Certificates and other certification details Publication 1757 INO21E EN P August 2009 26 Foundation Fieldbus Linking Device Additional Resources These documents contain additional information concerning related Rockwell Automation products Resource FOUNDATION Fi o dbus Wiring and Installation Application Guide publication at http www fieldbus org publication AG 140 Description Provides information on how to wire power and configure network components FOUNDATION Fieldbus Intrinsic Safe Systems Application Guide at http www fieldbus org publication Introduces you to the principals of intrinsic safety and outlines how to apply approved devices in a hazardous area FOUNDATION Fieldbus Linking Device User Manual publication 1757 UM010 Provides information needed to use the
23. s missing or not seated on the two rightmost pins or the battery is low or dead 2 NS 0 ot powered no IP address network Verify that power is supplied or assign an IP address status Flashing green o connections Verify that the linking device is connected to the fieldbus network Green CIP connections Flashing red Connection timeout Verify that the linking device is connected to the Ethernet network Flashing red Self test and green Publication 1757 IN021E E P August 2009 Foundation Fieldbus Linking Device 21 Linking Device Status Indicators Indicator Status Description MODE Solid green Linking device operational Flashing green Linking device out of service Verify that the Resource Block is set to Target Auto mode 1 If you already set the IP address and the Status and Mode indicators are flashing green you may have a duplicate IP address with another device on your network 2 If the BATT status indicator remains on after the jumper is replaced and power has been returned to the linking device contact Rockwell Automation Technical Support Specifications 1757 FFLD2 1757 FFLD4 Technical Specifications Attribute Physical interfaces Value 2 or 4 H1 FOUNDATION Fieldbus interfaces 1 10 100 Ethernet interface HSE IP Number of H1 networks per linking device 2 for 1757 FFLD2 linking device 4 for 1757 FFLD4
24. some important differences between solid state equipment and hard wired electromechanical devices Because of this difference and also because of the wide variety of uses for solid state equipment all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable n no event will Rockwell Automation Inc be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment he examples and diagrams in this manual are included solely for illustrative purposes Because of the many variables and requirements associated with any particular installation Rockwell Automation Inc cannot assume responsibility or liability for actual use based on the examples and diagrams 0 patent liability is assumed by Rockwell Automation Inc with respect to use of information circuits equipment or software described in this manual Reproduction of the contents of this manual in whole or in part without written permission of Rockwell Automation Inc is prohibited hroughout this manual when necessary we use notes to make you aware of safety considerations Identifies information about practices or circumstances that can cause an explosion in a hazardous environment which may lead to personal injury or death property damage or economic loss IMPORTANT dentifies information that is critical for successful application
25. und to comply with the Essential Health and Safety Requirements relating to the design and construction of Category 3 equipment intended for use in potentially explosive atmospheres given in Annex II to this Directive The examination and test results are recorded in confidential report 3172640DAL Compliance with the Essential Health and Safety Requirements has been assured by compliance with EN 60079 15 and EN 60079 0 This equipment must be installed in an enclosure providing at least IP54 protection when applied in Zone 2 environments e This equipment is not resistant to sunlight or other sources of UV radiation This equipment shall be used within its specified ratings defined by Allen Bradley Provision shall be made to prevent the rated voltage from being exceeded by transient disturbances of more than 40 when applied in Zone 2 environments Secure any external connections that mate to this equipment by using screws sliding latches threaded connectors or other means provided with this product Do not disconnect equipment unless power has been removed or the area is known to be nonhazardous Preventing Electrostatic Discharge This equipment is sensitive to electrostatic discharge which can cause internal damage and affect normal operation Follow these guidelines when A you handle this equipment e Touch a grounded object to discharge potential static e Wear an approved grounding wriststrap e Do not t
26. us devices and use the other for short term connection of diagnostic devices Perform the following steps to connect the H1 cables 1 Strip about 5 7 mm 0 2 0 28 in of the insulation at the ends of the cable leads 2 Insert the stripped cable end into the RTB following the layout on page 13 and tighten the screw Publication 1757 INO21E EN P August 2009 Foundation Fieldbus Linking Device 13 3 Complete step 1 and step 2 for all H1 cables 4 Insert the RTB into the corresponding socket H1 Terminal Block Layout catalog number 1757 FFLD4 shown PRSE STET OEOTOue DIO OTONO TOTO t Mee Cr Nr H1 1 H1 2 H1 3 H1 4 Power and Grounding You must use a power conditioner between your fieldbus power supply and the devices on the fieldbus network For more information see the FOUNDATION Fieldbus specifications at http www fieldbus org publication AG 140 Do not exceed 10 m 32 8 ft total wiring length on the 24V DC power connection 1 Connect the chassis ground to connector 1 CHASSIS GND 2 Connect the 24V common to connector 2 DC GND 3 Connect the 24V DC input power to connector 3 24V DC 420 1 CHASSIS GND 2 3 DC Gnd 24V DC 20 43576 4 Apply power to the linking device Publication 1757 IN021E EN P August 2009 14 Foundation Fieldbus Linking Device Configure the Linking Device The following instructions describe how to configure and set up
Download Pdf Manuals
Related Search
Related Contents
バラード MIC 胃瘻造設キット - ハリヤード・ヘルスケア・インク Adaptador IV a Bluetooth U1177A Keysight Instruções de operação Cedis SanDry Eco en Premium DEWALT DC550KA Use and Care Manual WS 8002 Manual KD-AVX40/KD-AVX20 ※施工上の注意とご使用上の注意はカタログー取扱説明書をお読み Sony SVE11125CXB Safety & Regulations Guide CA Network Flow Analysis - Manuel de l`opérateur Rayming TN-206 GPS Receiver - C:\Documents and Settings\RSJ\My Documents\Business Equipment\Rayming GPS BT TN Copyright © All rights reserved.