Home
Blackrock EIB-54K Omnetics Headstage Adapter
Contents
1. 2 EIB 54K Omnetics Headstage Adapter PN 7343 2 1 Connections to the Blackrock Neural Signal Processor and the A M Systems Four Channel Differential AC Amplifier are provided through connectors on the top of the adapter board A pin out of these connectors is provided below LEDs are provided for tracking with the NeuroMotive System All pin outs are viewed looking into the connector Connection to CerePlex M64 Bank B or C Connection to CerePlex M64 Bank A LED1 LED2 LEDs used for NeuroMotive tracking LED3 Connector J6 Connector J7 GND R2 oo CH31 CH32 CH29 99 oe CH27 ee CH28 CH25 26 CH23 22 CH24 tes CH21 60 CH22 19 ee CH20 CHI7 HH 8 CH15 CH16 CH13 o0 CH14 CHII HH CH12 CHO09 20 CH10 CH07 oo CHO08 CHO05 oe CH06 CH03 oo CH04 CHO1 CHO RI GND LB 0459 DRAFT Rev 1 00 BLACKROCK Page 3 MICROSYSTEMS EIB 54K Omnetics Headstage Adapter Instructions for Use 2 2 Connection to the Neuralynx EIB 54K Board The bottom of the adapter provides a direct connection to the Neuralynx EIB 54K board Pin outs for each connector are provided in the figure below All pin outs are viewed looking into the connector For mapping between the Neuralynx EIB 54K board and the Blackrock EIB 54K Omnetics Headstage Adapter refer to section 6 below a i on NJ x E m niiina 10 PPPELLI ES _ ro tt
2. meres e sai 8588 n P I AE 3 Dale to EIB 54K Omnetics Adapter PN 7344 Pin Out V Power Connection Provides power to LEDs for NeuroMotive tracking Dale Connector Stimulation Input Connectors Connects to differential stimulus channels on the EIB 54K Omnetics Headstage Adapter HDMI Type D Connector Stimulation Input Wire Connects to HDMI connector on the Blackrock CerePlex M64 Headstage LB 0459 DRAFT Rev 1 00 BLACKROCK Page 4 MICROSYSTEMS EIB 54K Omnetics Headstage Adapter Instructions for Use Pin D MM cae DATA a DATA CLK Stim black Stim blue 2 3 4 5 6 7 8 10 Not Connected 13 15 17 18 4 Dale to DAC A M 1700 Adapter PN 7345 Pin Out Stimulation Output Connector Dale Connector Connects to the stimulus connector of the A M Systems Differential AC Amplifier Model 1700 HDMI Type A Connector Connects to the HDMI connector on the Blackrock DAC DATA DATA Dale Connector Pin m DATA DATA Stim black Stim red 1 2 3 4 5 6 8 11 Not Connected 13 14 15 16 LB 0459 DRAFT Rev 1 00 BLACKROCK Page 5 MICROSYSTEMS EIB 54K Omnetics Headstage Adapter Instructions for Use Stimulation Output Wire Connector Pins Color Lm Be Refer to the A M Systems Four Channel Differential AC B Stim Black Amplifier user manual for further instructions regarding Not Connected the use of this s
3. Blackrock EIB 54K Omnetics Headstage Adapter PN 7343 2 BLACKROCK MICROSYSTEMS Blackrock Microsystems Inc 630 Komas Drive Suite 200 Salt Lake City UT 84108 Tel 866 806 3692 www blackrockmicro com EIB 54K Omnetics Headstage Adapter Instructions for Use 1 System Overview The EIB 54K Omnetics Headstage Adapter integrates a Blackrock 64 Channel Omnetics Headstage with a Neuralynx EIB 54 Kopf electrode interface board providing 48 electrode channels for recording neural signals 4 channels for recording from low impedance EMG electrodes and 2 sets of differential channels for providing stimulation stim and stim for return path Figure 1 below shows an application overview of how the EIB 54K Omnetics Headstage Adapter fits into a complete neural recording stimulation System Digital Hub Commutator Neural Signal Processor Dale to EIB 54K Omnetics Adaptbr Dale to DAC A M E 00000000 0000 PN 7345 CerePlex M64 Headstage 18 54 Omnetics Headstage Adapter PN 7343 Figure 1 EIB 54K Omnetics Headstage Adapter NOTE The Digital Hub CerePlex M64 Neural Signal Processor Commutator and the A M Systems Four Channel Differential AC Amplifier Model 1700 are not included in the packaging for this adapter and must be purchased separately LB 0459 DRAFT Rev 1 00 BLACKROCK Page 2 MICROSYSTEMS EIB 54K Omnetics Headstage Adapter Instructions for Use
4. Digital Hub and A M Systems Differential AC Amplifier Model 1700 for the set up and appropriate use of these systems 1 Turn off all power to the Neural Signal Processing System i e Digital Hub Neural Signal Processor and A M Systems Differential AC Amplifier Model 1700 before making any connections 2 Connectthe commutator to the Digital Hub and the Stimulus connector s on the A M Systems Differential AC Amplifier Model 1700 using the Dale to DAC A M 1700 Adapter Cable PN 7345 3 Connect the EIB 54K Omnetics Headstage Adapter PN 7343 to the Neuralynx EIB 54K interface board Use caution when making this connection and verify that all pins align correctly 4 Connect the Headstage to the Omnetics connectors of the EIB 54K Omnetics Headstage Adapter 7343 NOTE When connected the labeling on the Omnetics connectors should face the same direction 5 Connect the stimulation input connectors to the desired differential stimulation channels on the EIB 54K electrode interface board 6 Connect the power line from the Dale to EIB 54K Adapter Cable to the power connector on the EIB 54K Omnetics Headstage Adapter board All three LEDs on the surface of the adapter should light up 7 Connectthe EIB 54K Omnetics Headstage Adapter to the electrodes according to the instructions provided by Neuralynx for the use of the EIB 54K electrode interface board 8 Power on each system to begin stimulating and recording through the adapter
5. LB 0459 DRAFT Rev 1 00 BLACKROCK Page 8 MICROSYSTEMS EIB 54K Omnetics Headstage Adapter Instructions for Use 8 Warranty Blackrock Microsystems Inc warrants that its products are free from defects in materials and manufacturing for a period of one year from the date of shipment Blackrock will at its option repair or replace any product that does not comply with this warranty This warranty is voided by 1 Any modification or attempted modification to the product done by anyone other than an authorized Blackrock employee 2 Any abuse negligent handling or misapplication of the product This constitutes the sole warranty made by Blackrock LLC There are no other warranties expressed or implied which extend beyond those described herein or to anyone other than the original purchaser including the implied warranties of merchantability and fitness for a particular purpose In no event shall Blackrock Microsystems LLC be liable for any incidental or consequential damages or for the infringement of any patent rights or third party rights due to the use of its products 8 1 Return Merchandise Authorization RMA In the unlikely event that your adaptor needs to be returned to Blackrock for repair or maintenance do not send any equipment back without a Return Merchandise Authorization Number An RMA number will be issued to you by a Blackrock representative If you need to obtain an RMA number you may contact a product support repr
6. esentative at 801 582 5533 or toll free at 866 806 3692 Once an RMA number has been issued it is important to safely pack the returned item for shipping back to Blackrock It is preferred that you save the original boxes and packing materials that your system arrived in for return shipment Please address the package as follows Blackrock Microsystems LLC ATTN RMA 630 Komas Drive Suite 200 Salt Lake City UT 84108 USA Tel 801 582 5533 LB 0459 DRAFT Rev 1 00 BLACKROCK Page 9 MICROSYSTEMS
7. ystem 5 EIB 54K Interface Board Pin Layout Fae 9 lm 6 i Ds Al 5 2 2 25 dh Zl qu d 2 a 26 5 c7 a C qUES x EIB 54K Pin Layout Top View NOTE Each tetrode TT1 TT2 TT3 etc is laid out according to the diagram above when looking at the TT label right side up 6 EIB 54K Omnetics Headstage Adapter Channel Mapping The following table provides the channel mapping between the Neuralynx EIB 54K electrode interface board and the Blackrock 64 Channel Omnetics Headstage Electrode Channel NEURAL SIGNAL PROCESSOR EIB 54K EIB 54K ELECTRODE CHANNEL TETRODE TETRODE EEG CHANNEL LB 0459 DRAFT Rev 1 00 BLACKROCK Page 6 MICROSYSTEMS EIB 54K Omnetics Headstage Adapter Instructions for Use CH39 TT2 cHao cua cus TT3 cus CH30 cusi CH36 TT4 cus cua TTS cus cuo TT6 cu cun T TT7 m HDs cun CHI TTS cuo CHOS TT9 9 cHso TT10 cuis LB 0459 DRAFT Rev 1 00 BLACKROCK Page 7 MICROSYSTEMS EIB 54K Omnetics Headstage Adapter Instructions for Use Instructions for Assembly WARNING Always use antistatic or electrostatic discharge ESD safe gloves when connecting the EIB 54K Omnetics Adapter CAUTION Refer to the individual user manuals for the Neuralynx EIB 54K CerePlex M Headstage Blackrock Cerebus System