Home
Theta Inverter User Manual & Technical
Contents
1. fuse and battery connecting cables or car cigarette lighter port Indicator light on AC side WORK WORKING When inverter is working this light turns on ALARM WARNING When low voltage over voltage short circuit overload or thermal protection occur this light turns on www solarpower mart com www scorigin com Graphic illustration On LED Green Alarm LED Red Universal Power Socket www solarpower mart com www scorigin com Technical Specification Model SPM150MS SPM300MS SPM500MS SPM1000MS Continuous Power 150W 300W 500W 1 000W Surge Power 300W 600W 1 000W 2 000W Rated Output VAC 240V 10 Voltage Input Voltage DC11V 15V DC11V 15V DC11V 15V DC11V 15V Range Over Voltage Over DC 15V Shutdown Under Voltage Below DC 11V Shutdown Output Wave Form Modified Sine Wave Frequency 60Hz Over Load Yes Shutdown Thermal Shutdown Yes Short Circuit Yes Shutdown Efficiency Up to 90 Total Harmonic lt 5 Distortion No Load Current lt 0 3A lt 0 3A lt 0 4A lt 0 6A Draw Dimension mm 105 55 120 105 55 120 105 55 150 105 70 210 L x W x H Weight kg 0 6kg 0 7kg 0 8kg 1 8kg www solarpower mart com www scorigin com Model SPM2000MS SPM3000MS Continuous Power 2 000W 3 000W Surge Power 4 000W 6 000W Rated Output VAC 240V 10 Voltage Input Voltage DC22V 30V D
2. over rate the current drawn by their products If a piece of electrical or electronic equipment is rated at 300 watts or less the Theta 300W will probably operate it The inverter has overload protection so it is safe to try it with equipment rated at 300 watts or more The inverter will shut down if it is overloaded and will restart once the overload is removed Safety instructions This equipment should be installed and serviced by a qualified electrician or professional that is familiar with the inverter functions and operations Failure to do may result in injury or inverter damaged 1 Do not connect the Theta inverter unit to AC distribution wiring such as your house wiring 2 Keep the Theta inverter unit away from water Do not allow water to drip or splash onto the inverter Do not insert or pull out plug with wet hands 3 Keep the Theta inverter unit in cool environments Ambient air temperature should be between 0 C and 40 C Keep from direct sunlight and away from heating vents 4 Keep the Theta inverter unit away from flammable material or in any 5 With heavy usage the Theta inverter unit will become warm and possibly hot Keep it away from any heat sensitive materials 6 Make sure the opening to the ventilation fan and vent holes are not blocked 7 Do not open the Theta inverter unit because it is a high voltage device and can induce an electrical shock It may result in injury or even death 8 Use the prope
3. C22 30V Range Over Voltage Over DC 30V Shutdown Under Voltage Below DC 22V Shutdown Output Wave Form Modified Sine Wave Frequency 60Hz Over Load Yes Shutdown Thermal Shutdown Yes Short Circuit Yes Shutdown Efficiency Up to 90 Total Harmonic lt 5 Distortion No Load Current lt 0 6A lt 0 6A Draw Dimension mm 310 150 70 340 150 152 L x W x H Weight kg 2 7kg 3 3kg www solarpower mart com www scorigin com Model SPM300PS SPM500PS SPM1000PS Continuous Power 300W 500W 1 000W Surge Power 600W 1 000W 2 000W Rated Output VAC 240V 10 Voltage Input Voltage DC11V 15V DC11V 15V DC11V 15V Range Over Voltage Over DC 15V Shutdown Under Voltage Below DC 11V Shutdown Output Wave Form Pure Sine Wave Frequency 60Hz Over Load Yes Shutdown Thermal Shutdown Yes Short Circuit Yes Shutdown Efficiency Up to 90 Total Harmonic lt 5 Distortion No Load Current lt 0 6A lt 0 6A lt 0 8A Draw Dimension mm 150 130 52 210 150 70 310 150 70 L x W x H Weight kg 0 9kg 1 5kg 2 6kg www solarpower mart com www scorigin com Model SPM2000PS SPM3000PS Continuous Power 2 000W 3 000W Surge Power 4 000W 6 000W Rated Output VAC 240V 10 Voltage Input Voltage DC22V 30V DC22V 30V DC22V 30V
4. Range Over Voltage Over DC 30V Shutdown Under Voltage Below DC 22V Shutdown Output Wave Form Pure Sine Wave Frequency 60Hz Over Load Yes Shutdown Thermal Shutdown Yes Short Circuit Yes Shutdown Efficiency Up to 90 Total Harmonic lt 5 Distortion No Load Current lt 0 1A lt 0 1A Draw Dimension mm 395 150 70 370 150 152 L x W x H Weight kg 3 2kg 4 2kg www solarpower mart com www scorigin com SC ORIGIN LIMITED PRODUCT WARRANTY SC Origin manufactures its hardware products from parts and components that are new or equivalent to new in accordance with industry standard practices SC Origin warrants the Theta to be free from defects in workmanship or materials for 12 months from the date of purchase During this period SC Origin will at its option repair or replace the defective product free of charge This warranty will be considered void if the unit has suffered any physical damage or alteration either internally or externally and does not cover damage arising from improper use attempting to operate products with excessive power consumption requirements or from use in an unsuitable environment This warranty will not apply where the product has been misused neglected improperly installed or repaired by anyone other than SC Origin In order to qualify for the warranty the product must not be disassembled or modified without prior auth
5. ent air temperature should be between 0 C and 40 C ideally between 15 C and 25 C Do not place the inverter on or near a heating vent or any piece of equipment which is generating heat above room temperature Do not place the inverter in direct sunlight unnecessarily c Ventilated allow at least one inch of clearance around the Theta for air flow Do not place items on or over the inverter during operation Make sure that air is allowed to circulate freely around the unit A fan is helpful in the case where the inverter is operating at maximum power output for extended periods The unit will shut down if the internal temperature exceeds 90 C It will restart once it cools off CAUTION THETA CASE GETS HOT The case of the Theta acts as a heat sink dispersing internally generated heat When the Theta is operating at high power levels above 100 watts for extended periods the case will get hot Surface temperatures may approach 60 C 140 F on some parts of the case When operating at high power levels do not place the Theta on or near materials that may be affected by these temperatures Use caution when handling the Theta if it is operating at high power levels Safe do not use the Theta near flammable materials or in any location which may accumulate flammable fumes or gases www solarpower mart com www scorigin com Rated versus actual current draw of equipment Manufacturers of electrical and electronic equipment often
6. erference You can get minimum interference through use of a filter On some occasions when the interference of very weak signals becomes too obvious you can try the following e Place the inverter far from the TV and TV antenna e Try to change the direction of TV signal cable and TV antenna to reduce the interference to minimum e Use screen cable antenna of high quality Unresponsive Inverter 1 Poor connection between batteries amp inverter reconnect them 2 Reverse polarity connection and fuse burned out replace the fuse with a same spec fuse and reconnect Output voltage very low 1 Overload Load power exceeds rated power shut off part of the appliances and restart inverter 2 Input voltage too low Make sure input voltage is within the rated range Low voltage alarm 1 Battery has no power Recharge the battery via charger or solar 2 Battery voltage too low or in poor connection Recharge the batteries check terminal connection or clean terminals with a dry cloth Inverter no output 1 Battery voltage too low recharge or replace the batteries 2 Load power too high shut off some of the appliances and restart inverter 3 Inverter thermal protection Cool the inverter and place it in an area with good ventilation 4 Inverter start up fails Restart the inverter 5 Reverse polarity connection and fuse burned out replace the fuse with a same spec fuse and reconnect Inverter does not work Check the power switch
7. eta Works An inverter is an electronic device that converts low voltage DC direct current electricity from a battery or other power source to the standard 240 volts AC alternating current household power In designing the Theta SC Origin has used design techniques previously employed in computer power supplies to give you an inverter that is smaller lighter and easier to use than any other inverter with a similar power rating Principle of operation The Theta converts power in two stages The first stage is a DC to DC converter that raises the low voltage DC at the inverter input to 240 volts DC The second stage is the actual inverter stage It converts the high voltage DC into 240 volts 60 Hz or 50 Hz AC The DC to DC converter stage uses modern high frequency power conversion techniques that makes the bulky transformers found in inverters based on older technology obsolete The inverter stage uses advanced power MOSFET transistors in a full bridge configuration This gives you excellent overload capability and the ability to operate tough reactive loads like lamp ballasts and small induction motors Theta Modified Sine Wave output waveform The AC output waveform of the Theta is called a quasi sine wave or a modified sine wave It is a stepped waveform that is designed to have characteristics similar to the 3 sine wave shape of utility power A waveform of this type is suitable for most AC loads including linear and switching p
8. m which indicates DC power supply voltage is descending and batteries need to recharge B When input voltage is below 10V 0 5V for 12V input inverter 20V 1 0V for 24V input inverter AC output will be automatically shut off a buzzer alarm and ALARM WARNING light turns red at the same time www solarpower mart com www scorigin com Input over voltage protection When input voltage reach 15V 0 5V for 12V input inverter 30V 1 0V for 24V input inverter ALARM WARNING light turns red and the AC output will be shut off automatically Short circuit protection When short circuits occur output will be shut off and ALARM WARNING light turns red Overload protection When overloads occur output will be shut off and ALARM WARNING light turns red Reverse polarity input protection When battery terminals are reverse connected fuse will be burned to protect appliances Invert thermal protection When inner temperature exceeds 70 C AC output will automatically shut off ALARM WARNING light turns red It is unusable for 15 minutes Charge thermal protection When radiator temperature exceeds 50 C the inner cooling fan will automatically turn on to cool the inverter www solarpower mart com www scorigin com TROUBLESHOOT amp SOLUTION Acoustics buzzer alarms When applying the inverter to acoustics devices some inferior acoustics devices will buzz this is because the output wave from the inverter is a modified sine wave TV Int
9. orization by SC Origin Repair or replacement are your sole remedies and SC Origin shall not be liable for damages whether direct incidental special or consequential if caused by negligence or fault SC Origin owns all parts removed from repaired products SC Origin uses new and reconditioned parts made by various manufacturers in performing warranty repairs and building replacement products If SC Origin repairs or replaces a product its warranty term is not extended THIS IS A SC ORIGIN ONLY WARRANTY AND THE COMPANY MAKES NO WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE LIMITED LIABILITY The Limited Warranty set forth herein are expressly in lieu of and exclude all other expressed or implied warranties including but not limited to warranties of merchantability and of fitness for particular purpose use or application and all other obligations or liabilities on the part of SC Origin unless such other warranties obligations or liabilities are expressly agreed to in writing signed and approved by SC Origin SC Origin shall have no responsibility or liability whatsoever for damage or injury to persons or property or for other loss or injury resulting from any cause whatsoever arising out of or related to misuse or installation of the inverters Under no circumstances shall SC Origin be liable for incidental consequential or special damages howsoever caused Loss of use lo
10. ower supplies used in electronic equipment transformers and motors This waveform is much superior to the square wave produced by many other DC to AC inverters The modified sine wave produced by the Theta is designed to have a RMS root mean square voltage of 240 volts the same as standard household power Most AC voltmeters both digital and analog are sensitive to the average value of the waveform rather than the RMS value They are calibrated for RMS voltage under the assumption that the waveform measured will be a pure sine wave These meters will not read the RMS voltage of a modified sine wave correctly They will read about 2 to 20 volts low i e about 230V when measuring the output of the Theta For accurate measurement of the output voltage of the Theta a true RMS reading voltmeter such as a Fluke 87 Fluke 8060A Beckman 4410 or Triplett 4200 must be used www solarpower mart com www scorigin com Installation Power source For optimum performance the power source must provide between 11 and 14 5 volts 22 30 volts for Theta 24V input system and must be able to supply sufficient current to operate the load The power source may be a battery or a well regulated DC power supply As a rough guideline divide the power consumption of the load in watts by 10 by 20 for Theta 24V input system to obtain the current in amperes the power source will deliver Example Load is rated at 120 watts Power source will be able to deli
11. r size wiring provided The Theta inverters can draw many amps from the DC source and can easily melt wires if not fused and sized properly 9 Make sure to connect the Theta inverter with battery batteries correctly Reverse polarity connection may burn invert fuse Immediate switch off the inverter and do not use the equipment 10 When cleaning the Theta inverter please switch off power unplug the inverter Carefully clean with dry cloth Do not use wet cloth or cleanser How to use the Theta Inverter 1 Power supply selection It must get power from storage battery batteries or a car cigarette lighter port Input voltage can be 12Vor 24V or 48V depending on the model 1 Connect Theta inverter to power supply Set the switches into the OFF position including inverter and appliances 2 Get power from battery batteries Connect the black U shape end of battery cable with the Black connecting pole of inverter and the red U shape end with the red connecting pole 3 Get power from car cigarette lighter port insert the car cigarette lighter plug into the car cigarette lighter port 4 Connect inverter to appliances Make sure the load power within the rated power of inverter and the start power should not exceed the peak power of the inverter When having the inverter connected with appliances and a power supply switch on the inverter and appliances Input low voltage protection A When battery voltage is low a buzzer will alar
12. sc Origin Inspired by the Sun Theta Inverter User Manual FEATURES amp BENEFITS e True sine wave output THD 5 Typ Input amp output fully isolated Thermo control cooling fan High efficiency inverter Advanced microprocessor Input polarity reverse under voltage over voltage protection e Output short circuit overload over temperature protection e Capable of driving highly reactive and capacitive loads e LED Color indicators display input output level amp failure status e CE and ROSH Approved e Quality construction amp durability Solar Power 2 Mart Harvest the Sunpower www solarpower mart com www scorigin com Introduction Your new Theta power inverter is a member of the most advanced line of DC to AC inverters available today It will give you years of dependable service in your vehicle boat RV or remote home To get the most out of your Theta inverter it must be installed and used properly Please read the installation and operating instructions in this manual carefully before installing and using your Theta Inverter Pay special attention to the CAUTION and WARNING statements in this manual and on the Theta Inverter CAUTION statements identify conditions or practices which could result in damage to your Theta inverter or to other equipment WARNING statements identify conditions or practices that could result in personal injury or loss of life CAUTION WARNING How Your Th
13. ss of profits loss of production and loss of revenues are therefore specifically excluded Send product purchased in Pan Asia to SC Origin M Sdn Bhd No 87 Jalan TPP 1 13 Taman Industri Puchong 47100 Puchong Selangor THE LIMITED WARRANTY IS THE ONLY WARRANTY OF SC ORIGIN M SDN BHD THERE ARE NO OTHER WARRANTIES EXPRESSED OR IMPLIED EXCEPT AS PROVIDED BY LAW INCLUDING THE IMPLIED WARRANTY OF QUALITY MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND SUCH IMPLIED WARRANTIES IF ANY ARE LIMITED IN DURATION TO THE TERM OF THE LIMITED WARRANTY ROHS compliant b 4 Solar Power 2 Mart Think before Harvest the Sunpower you print D www solarpower mart com www scorigin com
14. ver 120 10 12 amps or 6 amps for Theta 24V input system CAUTION The Theta must be connected only to batteries with a nominal output voltage of 12 volts 24 volts for Theta 24V input system The Theta will not operate from a 6 volt battery and will be damaged if connected to a voltage source above 16 volts WARNING RISK OF EXPLOSIVE GASES Sparks may occur when connecting the inverter to the battery These sparks can ignite accumulated battery gases and cause an EXPLOSION VENTILATE BATTERY IMMEDIATELY BEFORE CONNECTING BATTERY TO INVERTER For temporary connections a Connect the inverter s positive DC wire clip to the positive battery terminal b Connect the inverter s negative DC wire clip to the free end of the cable negative When disconnecting the inverter always do so in the reverse sequence of the connecting procedure and break the first connection as far away from the battery as possible The purpose of this procedure is to eliminate the possibility of a spark from the battery when connecting and disconnecting to avoid possible ignition of gases Placement of inverter For best operating results the inverter should be placed on a flat surface such as the floor or seat of a vehicle Approximately 0 6 m 2 feet of cord has been provided for this purpose The inverter should only be used in locations that meet the following requirements a Dry do not allow water to drip or splash onto the Theta b Cool ambi