1. 92 00 56 00 Figure 2 1 EKI 6528T1 6528TPI Dimensions EKI 6528T1 6528TPI User Manual 6 2 3 Mounting The EKI 6528T TPI supports two mounting methods DIN rail amp Wall 2 3 1 Wall mounting 1 Attach the brackets included to the switch with screws 2 With the brackets attached hang the switch to nails on the wall Figure 2 2 Attaching the Metal Mounting Kit 7 EKI 6528TI 6528TPI User Manual 2 3 2 DIN rail Mounting 1 Align the screw holes between the DIN rail clip and the unit 2 Hang the device to the DIN rail 3 Hook the device over the DIN rail and let it drop down straight to slide over the rail smoothly Figure 2 3 DIN rail Installation 2 4 Network Connection Prepare the M12 4 pole D Coded Fast Ethernet Port mating cable for Ethernet con nection The M 12 D coded Fast Ethernet ports are auto sensing for 10Base T or 100Base TX devices connections Auto MDI MDIX means that you can connect to another switch or workstation without changing straight through or crossover cabling 1 TX 2 RX O O 3 TX 4 RX Figure 2 4 Network Connector EKI 6528T1 6528TPI User Manual 8 2 5 Power Connection Prepare the M12 5 pole A Coded cable for Ethernet connection Connect the posi tive and negative wires to PWR1 V1 V1 and PWR2 V2 V2 as the power pin assignments shown below 1 V1 2 V2 JO O 3 V2 3 O5 4 4 V1 Figure 2 5 Power Connector 2 6 Grounding the Ethern
2. User Manual EKI 6528T1 6528TPI EN50155 8 port M12 Unmanaged PoE Switch with Wide Temperature AD ANTECH eAutomation Copyright The documentation and the software included with this product are copyrighted 2006 by Advantech Co Ltd All rights are reserved Advantech Co Ltd reserves the right to make improvements in the products described in this manual at any time without notice No part of this manual may be reproduced copied translated or transmitted in any form or by any means without the prior written permission of Advantech Co Ltd Information provided in this manual is intended to be accurate and reliable How ever Advantech Co Ltd assumes no responsibility for its use nor for any infringe ments of the rights of third parties which may result from its use Acknowledgements Intel and Pentium are trademarks of Intel Corporation Microsoft Windows and MS DOS are registered trademarks of Microsoft Corp All other product names or trademarks are properties of their respective owners Product Warranty 2 years Advantech warrants to you the original purchaser that each of its products will be free from defects in materials and workmanship for two years from the date of pur chase This warranty does not apply to any products which have been repaired or altered by persons other than repair personnel authorized by Advantech or which have been subject to misuse abuse accident or improper installation Advant
3. to your dealer Edition 1 January 2011 EKI 6528T1 6528TPI User Manual ii Declaration of Conformity CE This product has passed the CE test for environmental specifications when shielded cables are used for external wiring We recommend the use of shielded cables This kind of cable is available from Advantech Please contact your local supplier for ordering information CE This product has passed the CE test for environmental specifications Test conditions for passing included the equipment being operated within an industrial enclosure In order to protect the product from being damaged by ESD Electrostatic Discharge and EMI leakage we strongly recommend the use of CE compliant industrial enclo sure products FCC Class A Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Opera tion of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Technical Support and Assistance 1 Visit th
4. EC 704 1 Advantech disclaims all responsibility for the accuracy of any statements contained herein Safety Precaution Static Electricity Follow these simple precautions to protect yourself from harm and the products from damage To avoid electrical shock always disconnect the power from your PC chassis before you work on it Don t touch any components on the CPU card or other cards while the PC is on Disconnect power before making any configuration changes The sudden rush of power as you connect a jumper or install a card may damage sensitive elec tronic components EKI 6528T1 6528TPI User Manual iv Contents Chapter Chapter Chapter 1 2 4 2 5 2 6 3 1 Overview eren 1 Introduction ai 2 Features 2 Specifications iie dep ii pepe 2 Installation 5 LED Indicators 214 cette nent 6 Table 2 1 EKI 6528TI LED DefinitioNS 6 Dimensions units mm 1 e siat arena 6 Figure 2 1 EKI 6528T1 6528TPI Dimensions 6 Mounlting eT id an nt ntfs 7 2 3 1 Wall mountitig carla iano 7 Figure 2 2 Attaching the Metal Mounting Kit 7 2 9 2 DINerall MOUN essen 8 Figure 2 3 DIN rail Installation sess 8 Network Connection 8 Figure 2 4 Network Connector 8 Power Connection aen iie a ap eaa nn eaae ina 9 Figure 2 5 Power Connector 9 Grounding the Ethern
5. Ethernet Switch B 2x Wall mount plates with screws B 1xDIN rail clip with screws WB 1x EKI 6528TI 6528TPI startup manual m 1x User Manual CD ROM If anything is missing or damaged contact your distributor or sales representative immediately Safety Precaution ATTENTION IF DC voltage is supplied by an external circuit please use a protection device on the power supply input 3 EKI 6528TI 6528TPI User Manual EKI 6528TI 6528TPI User Manual Chapter 2 Installation 2 1 LED Indicators LED indicators located on the front panel display the status of system power net working and power feeding over Ethernet of the Ethernet switch Please refer to the following table for further details Table 2 1 EKI 6528TI LED Definitions LED Color Description PWR1 Green On Power input 1 is active Off Power input 1 is inactive PWR2 Green On Power input 2 is active Off Power input 2 is inactive LNK ACT Green On Connected to network Blinks Data is transmitting receiving Off Not connected to network PoE port 5 8 Green On A powered device is connected utilizing PoE on the EKI 6528TPI port Off No device is connected or power forwarding fails 2 2 Dimensions units mm i rol uer 1 Er a De 38 x 8 O g _ pu ou TT ii Br En al e 28 00 3 L Unit mm
6. e Advantech web site at www advantech com support where you can find the latest information about the product 2 Contact your distributor sales representative or Advantech s customer service center for technical support if you need additional assistance Please have the following information ready before you call Product name and serial number Description of your peripheral attachments Description of your software operating system version application software etc Acomplete description of the problem The exact wording of any error messages Safety Instructions 1 Read these safety instructions carefully 2 Keep this User Manual for later reference 3 Disconnect this equipment from any AC outlet before cleaning Use a damp cloth Do not use liquid or spray detergents for cleaning 4 For plug in equipment the power outlet socket must be located near the equip ment and must be easily accessible 5 Keep this equipment away from humidity iii EKI 27281 User Manual 10 11 12 13 14 15 16 17 Put this equipment on a reliable surface during installation Dropping it or letting it fall may cause damage The openings on the enclosure are for air convection Protect the equipment from overheating DO NOT COVER THE OPENINGS Make sure the voltage of the power source is correct before connecting the equipment to the power outlet Position the power cord so that people cannot step o
7. ech assumes no liability under the terms of this warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous testing most of our customers never need to use our repair service If an Advantech product is defec tive it will be repaired or replaced at no charge during the warranty period For out of warranty repairs you will be billed according to the cost of replacement materials service time and freight Please consult your dealer for more details If you think you have a defective product follow these steps 1 Collect all the information about the problem encountered For example CPU speed Advantech products used other hardware and software used etc Note anything abnormal and list any onscreen messages you get when the problem occurs 2 Call your dealer and describe the problem Please have your manual product and any helpful information readily available 3 If your product is diagnosed as defective obtain an RMA return merchandize authorization number from your dealer This allows us to process your return more quickly 4 Carefully pack the defective product a fully completed Repair and Replacement Order Card and a photocopy proof of purchase date such as your sales receipt in a shippable container A product returned without proof of the purchase date is not eligible for warranty service 5 Write the RMA number visibly on the outside of the package and ship it prepaid
8. et Switch 9 Figure 2 6 Grounding ScreWSs nn 9 Troubleshooting 11 Troubleshooting 2 tte E en 12 3 1 1 Power Input tio c dad caa d ee tnt palio 12 9 12 Cable oder HEU ebenda 12 3 1 3 Diagnosing LED Indicators nn nennen 12 V EKI 6528TI User Manual EKI 6528TI 6528TPI User Manual vi Chapter 1 Overview 1 1 Introduction EKI 6528TI and EKI 6528TPI are EN50155 compliant industrial switches with IP40 protection and wide temperature support designed for railway applications EKI 6528TPI provides 4 x PoE ports that support IEEE 802 3af and can provide up to 15 4 watts of power per port M12 connectors ensure highly reliable connectivity for industrial communication applications With IP40 compact metal housings these switches are protected against dusty environments and are a good fit for many industrial applications Under no power condition Auto Bypass function ensures the Ethernet signal connection through internal circuitry This feature provides non stop communication to rolling stocks even no power exists in some of the carriages 1 2 Features Back plane switching fabric 1 6Gbps M12 connectors and IP40 metal housing Four IEEE 802 3af compliant PoE ports EKI 6528TPI Each PoE port provides up to 15 4 watts at 24 48 VDC Wide range redundant power design Wide operating temperature 40 75 C EN50155 50121 3 2 50121 4 1 3 Specificat
9. et Switch Follow the instructions below to attach the Ethernet switch to ground Figure 2 6 Grounding Screws 9 EKI 6528TI 6528TPI User Manual EKI 6528T1 6528TPI User Manual 10 Chapter 3 Troubleshooting 3 1 Troubleshooting 3 1 1 Power Input Verify that you are using the correct power cord adapter Don t use the power adapter with DC output higher than the rated voltage of the equipment Or the equipment will be damaged 3 1 2 Cable Select proper cables to construct your network Please check that you are using the correct cables 3 1 3 Diagnosing LED Indicators Diagnosing LED Indicators the equipment can be easily monitored through panel indicators which describes common problems you may encounter and where you can find possible solutions to assist in identifying problems If the power indicator does not light up when the power cord is plugged in you may have a problem with power cord Then check for loose power connections power losses or surges at power outlet If you still cannot resolve the problem contact your local dealer for assistance If the LED indicators are normal while the corresponding cables are connected correctly but the networking is still inactive please check your system s Ethernet devices configuration or status EKI 6528T1 6528TPI User Manual 12 13 EKI 6528TI 6528TPI User Manual AD ANTECH eAutomation www advantech com Please verify speci
10. fications before quoting This guide is intended for reference purposes only All product specifications are subject to change without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permis sion of the publisher All brand and product names are trademarks or registered trademarks of their respective companies O Advantech Co Ltd 2011
11. ions Communications E Standard IEEE 802 3 10Base T IEEE 802 3u 100Base TX EEE 802 3x Flow control and back pressure IEEE 802 3af Power over Ethernet EKI 6528TPI m LAN 10 100Base TX B Transmission Speed Upto 100 Mbps WB Switch Architecture Back plane 1 6Gbps Interface M Connectors 8x M12 4 pole D coded female 10 100TX 1xM12 5 pole A coded male Power WB LED Indicators System PWR1 PWR2 10 100Base TX port LNK ACT PoE EKI 6528TPI Power m 3 36W max 48VDC EKI 6528TI m 72 W max 24 VDC EKI 6528TPI EKI 6528T1 6528TPI User Manual 2 Mechanism W Dimensions WxHxD 92 x 180 x 42 mm B Enclosure IP40 protection metal housing WB Mounting DIN rail Wall mount Environment M Operating Temperature 40 75 C Operating Humidity 5 95 non condensing M Storage Temperature 40 85 C B MTBF EKI 6528TI 391 306 hours EKI 6528TPI 348 384 hours Certifications M Safety UL cUL 60950 a EMC CE FCC Class A CE EN61000 6 2 CE EN61000 6 4 CE EN61000 4 2 ESD CE EN61000 4 3 RS CE EN61000 4 4 EFT CE EN61000 4 5 Surge CE EN61000 4 6 CS CE EN61000 4 8 Magnetic Field a Railway EN50155 EN50121 3 2 EN50121 4 im Free Fall IEC60068 2 32 Shock IEC61373 E Vibration IEC61373 Packing List Before installation please make sure that you have received the following B 1x EKI 6528T1 6528TPI Industrial Unmanaged
12. n it Do not place anything over the power cord All cautions and warnings on the equipment should be noted If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient overvoltage Never pour any liquid into an opening This may cause fire or electrical shock Never open the equipment For safety reasons the equipment should be opened only by qualified service personnel If one of the following situations arises get the equipment checked by service personnel The power cord or plug is damaged Liquid has penetrated into the equipment The equipment has been exposed to moisture The equipment does not work well or you cannot get it to work according to the user s manual The equipment has been dropped and damaged The equipment has obvious signs of breakage DO NOT LEAVE THIS EQUIPMENT IN AN ENVIRONMENT WHERE THE STORAGE TEMPERATURE MAY GO BELOW 20 C 4 F OR ABOVE 60 C 140 F THIS COULD DAMAGE THE EQUIPMENT THE EQUIPMENT SHOULD BE IN A CONTROLLED ENVIRONMENT CAUTION DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY REPLACED REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE RECOMMENDED BY THE MANUFACTURER DISCARD USED BATTERIES ACCORDING TO THE MANUFACTURER S INSTRUCTIONS The sound pressure level at the operator s position according to IEC 704 1 1982 is no more than 70 dB A DISCLAIMER This set of instructions is given according to I