Intradoor, Inc User`s Manual Railmaster Sliding Door Controller (SDC)
Contents
1. 2 Demolition For demolition of the Railmaster the following needs to be done 1 Execute steps 1 6 from paragraph 9 1 2 Remove the power supply 3 If needed the Railmaster can be taken apart further into parts 9 3 Storage Storage of new and reusable Railmasters has to find place in spaces that comply with the following environmental specifications temperature 5 C 40 C 41 F 104 F maximum humidity 90 at 20 C 68 F 50 at 40 C 104 F 9 4 Transport Transport of the Railmaster has to be done in such a way that there is no chance of damage User s Manual Railmaster SDC 10 1 10 Malfunctions and Repairs Malfunctions The door does not close completely Follow the next steps to solve this malfunction Turn off the power supply of the Railmaster by pulling the plug from the socket Operate the door with one of the sensors to make sure the door closes properly and completely In case the door still doesn t close properly or completely repeat these steps until it does Measure the distance that the door still has to travel from where it is to where it is fully closed Slide the door open far enough to make sure that the 50 millimeter position sticker which detects the closed position is accessible Mark the spot where the sticker is Remove the sticker from the driving belt Add the distance between the 30 millimeter position sticker and the marked position to the distance that
2. of the sensor Mount the mounting unit on the door Press the reset button of the printboard for 3 seconds Operate a sensor or the RF manual emitter to open the door The door will slowly open entirely and then stop After the programmed amount of timethat the door is open the door will again close Make sure the door closes properly If the door does not close properly follow the guidelines under paragraph 5 4 Build the framing around the door opening The door is ready for use 5 1 Tuning e Follow the following guidelines if the door is not properly closed Turn off the power supply of the Railmaster by pulling the plug from the socket Measure the distance that the door still has to travel from where it is to where it is fully closed Slide the door open far enough to make sure that the 50 millimeter position sticker which detects the closed position is accessible Mark the spot where the sticker is Remove the sticker from the driving belt Add the distance between the 30 millimeter position sticker and the marked position to the distance that the door still has to travel to close completely Attach the position sticker to the belt on this spot Put the plug of the power supply back in the socket Operate the door with one of the sensors to make sure the door closes properly and completely User s manual Railmaster SDC In case the door still doesn t close properly or completely repeat t
3. supply MUST NOT be placed in zone 0 or 1 Ignoring the following safety instructions can be of Mortal Danger Mortal Danger The Railmaster system uses a 230 VAC current Any maintenance or repair has to happen when the current is off The system needs to be unplugged Any repair or maintenance on the system can be of mortal danger when the power supply is still connected to any electrical current Warning Before the installer of the Railmaster releases the system for general use the installer needs to test the system and make sure the system is installed properly and works correctly Ignoring this safety instruction can cause dangerous situations and harm to any normal user User s manual Railmaster SDC Warning Prohibit children from playing with the control buttons of the Railmaster system Do not let children play with the remote controls of the Railmaster system Ignoring these safety instructions may cause dangerous situations and harm to any normal user User s manual Railmaster SDC 4 Description of the Railmaster 4 1 Operation The normal position of a door that is controlled by the Railmaster SDC is a closed position After operating the sensor the door will open at high speed At a moment that is determined during installation the door will slow down to low speed and stops when the door is opened completely The door will stay open for a predetermined period and will automatically close The door will start clo
4. the door still has to travel to close completely Attach the position sticker to the belt on this spot Put the plug of the power supply back in the socket The door runs into the frame during opening or closing Follow the next steps to solve this malfunction Turn off the power supply of the Railmaster by pulling the plug from the socket Slide the door open far enough to make sure that the 50 millimeter position sticker which detects the closed position is accessible Mark the spot where the sticker is Remove the sticker from the driving belt Attach the position sticker a little closer to the 30 millimeter position Put the plug of the power supply back in the socket Operate the door with one of the sensors to make sure the door closes properly and completely User s Manual Railmaster SDC Incase the door still doesn t close properly or completely repeat these steps until it does e Overige storingen For all other malfunctions the manufacturer needs to be contacted 10 2 Repairs For repairs of the Railmaster and for replacing the driving belt the manufacturer needs to be contacted In case the Railmaster comes supplied with a power supply from another manufacturer replacing the wiring of the power supply may only be done by qualified personnel User s Manual Railmaster SDC 11 Environment and Waste The Railmaster does not contain dangerous materials All parts of the Railmaster can be recycled o
5. User s manual Railmaster SDC Intradoor Inc User s Manual Railmaster Sliding Door Controller SDC Version 1 Date of Edition 11 03 08 Publisher Intradoor Inc Address 2850 Elmwood Avenue Rochester NY 14618 Telephone 1 585 752 7525 E mail info intradoor com Web www intradoor com User s manual Railmaster SDC User s Guide To be used by This user s guide is to be used by anyone who is to perform any work with or on the Railmaster Work in this context means Installation Setting Up Changing any settings on the Railmaster Using the Railmaster in any way Performing any service or repairs on the Railmaster Minimum level of knowledge and experience The person who is to perform any work with or on the Railmaster must have enough technical knowledge and experience to perform these actions safely He or she is knowledgeable with the use of a PDA Personal Digital Assistant and he or she is trained for the installation of the Railmaster by the manufacturer Clues for the use of this manual The user of this manual must at all times comply with any safety precautions in this manual in addition to any general safety precautions and common sense The failure to follow these precautions may lead to dangerous situations for the user and or others Explanation of terminology Attention Additional information or a possible problem Warning Failure to carefully follow the manual s instructions may cau
6. Wattage Motor Type RPM Performance Specifications At 160 RPM At 540 RPM Dimensions Driving Unit Turning Wheel Unit Door Mounting Unit Weight Specification Maximum Door Weight Sensor Specifications Manual sensors sensor 1 and 2 Automatic Sliding Door Controller Railmaster Pocket Wall mount Bypass and Multi pass doors Manual contacts Contact mats Manual remote controls RF remote controls Central controls etc Locks Fire Doors 5 C 40 C 41F 104F 90 at 20 C 68F 50 at 40 C 104F 24 VDC 6A VDS 1 5 mm2 VMDS 1 mm2 0 5 Watt 145 Watt Valeo GPMG 404 160 RPM max 0 3 m s adjustable in 5 steps max 0 8 m s adjustable in 5 steps 160 x 90 x 90 mms 150 x 45 x 45 mms 90 x 90 x 5mms 100 kg 220 Ibs Potential Free Contact User s manual Railmaster SDC Fire Alarm Sensor sensor 3 RF sensor Remarks Driving Belt Maintenance Intervals Settings IP classification Controls Power Supply 110 VAC 24 VDC Applied Normatives Driver Controls Power Supply 110 VAC 24 VDC Pictograms Sound Emission Potential Free Contact 434 MHz Manual Emitter When several manually controlled wired sensors control one door all sensor contacts can be connected to work parallel PU Aramite The Railmaster SDC is completely maintenance free Freely programmable with Personal Digital Assista
7. e door and the presence of electrical current it will always be possible to open and close the door manually User s Manual Railmaster SDC 7 Maintenance and Cleaning The Railmaster SDC is completely maintenance free Once a year the connection of the door assembler needs to be checked The Railmaster SDC and the power supply need to be checked regularly conform the demands of NEN 3140 The cleaning of the complete automatic sliding door system needs to be executed conform the instructions of the door supplier User s Manual Railmaster SDC 8 Switching Off The Railmaster SDC needs to be switched off by pulling the plug from the socket The door can still be operated manually User s Manual Railmaster SDC 9 Deconstruction Demolition Storage and Transport 9 1 Deconstruction The Railmaster can be deconstructed using the following guidelines 1 Remove the Railmaster from any current by pulling the plug of the power supply from the socket If the power supply is connected directly to the wiring in the wall the connection clamps and the wiring need to be disconnected from the power supply 2 Disconnect the door from the mounting unit 3 Remove the door following the guidelines of the door supplier 4 Remove the framing around the door opening 5 Disconnect the wiring from the printboard power supply sensor s fire alarm connections 6 Unscrew the Railmaster and remove the Railmaster from the door frame 9
8. hese steps until it does e Follow the following instructions if the door runs into the frame at slow speed Turn off the power supply of the Railmaster by pulling the plug from the socket Slide the door open far enough to make sure that the 50 millimeter position sticker which detects the closed position is accessible Mark the spot where the sticker is Remove the sticker from the driving belt Attach the position sticker a little closer to the 30 millimeter position Put the plug of the power supply back in the socket Operate the door with one of the sensors to make sure the door closes properly and completely In case the door still doesn t close properly or completely repeat these steps until it does User s Manual Railmaster SDC 6 Use 6 1 Normal Use The normal position of a door that is controlled by the Railmaster is a closed position After operating the sensor the door will open at high speed At a moment that is determined during installation the door will slow down to low speed and stops when the door is opened completely The door will stay open for a predetermined period and will automatically close The door will start closing at high speed and will slow down at a predetermined moment to low speed until it is fully closed When the door comes in contact with an obstacle during opening or closing it will change direction and start moving at low speed 6 2 Manual Control Regardless of the position of th
9. nt PDA and software package SD Toolkit IP 00 IP 44 EN 294 EN 349 EN 811 EN 60204 1 EN 61000 6 1 EN 61000 6 3 EN 55022 EN 61000 3 2 3 EN 61000 4 2 3 5 6 8 11 ENV 50204 EN 55024 NEN 3011 The level of produced sound pressure created by the Railmaster SDC is less than 70 dB A User s manual Railmaster SDC Door Types The Railmaster SDC can be applied with the following door types ine M Pocket doors E M Wall Mounted Doors mm Picture 1 Possible Door Types User s manual Railmaster SDC 3 Precautions and safety instructions The installer of a Railmaster system The installer of a Railmaster system possesses a minimum of relevant technical education at WEB level 2 and has sufficient experience Installation of a Railmaster system may only be executed by a qualified installer that has received education from the manufacturer The maintenance technician of the Railmaster system The maintenance technician of the Railmaster system possesses a minimum of relevant technical education at WEB level 2 and has sufficient experience Repairs of a Railmaster system may only be executed by a qualified installer that has received education from the manufacturer Assembly in wet spaces Bathrooms When a Railmaster system is assembled to control an entrance for wet bathrooms the printboard MUST NOT be placed in zone 0 When using the 230 VAC 24 VDC power supply the power
10. r handled as normal waste
11. se personal injury and or damage to the machine Danger Mortal danger threat of loss of life Pictograms The following pictograms appear on the Railmaster Dangerous Electric Current Danger Only on externally sliding doors User s manual Railmaster SDC 1 Foreword The function of the Railmaster The Railmaster is an operating system for automatic opening and closing of doors in residences health care centers and offices Opening the door can happen using several manual or automatic sensors Closing will take place after a certain predetermined programmable time The Railmaster can also be connected to a centralized fire alarm system In case of a fire the door that is controlled by the Railmaster can fulfill a roll as fire door To prevent blocking an escape route the door controlled by the Railmaster can always be opened manually whether or not there is electrical current Unprescribed Use The Railmaster is not suitable for use to open exterior doors The Railmaster is not suitable for use in an industrial environment The Railmaster is not suitable for use in an area with danger of explosion User s manual Railmaster SDC 2 Technical Specifications Description Type Area of Application Controls Extra functions Environmental Influences Temperature Maximum Humidity Electric Specifications Motor Voltage Amperage Power Supply Connection Non operational Wattage Operational
12. sing at high speed and will slow down at a predetermined moment to low speed until it is fully closed 4 2 Controls The Railmaster SDC can be controlled in four different ways Using a manually controlled contact This contact can be activated using a button Using a person detection system The presence of persons can for instance be detected using a radar or an IR sensor Using a RF sensor Using a fire alarm system When the Railmaster SDC is connected to an activated fire alarm system the door will automatically close The door can still be controlled using the RF manual emitter and simple manual control is also still possible 4 3 Safety Measures The Railmaster SDC is equiped with several safety measures which guarantee that with normal use of the door no situations will arise where people can get hurt All safety measures are automatic Warning When the power supply is connected to the electric point the printboard is under electric current Touching the track side of the printboard with a conducting part can cause a short circuiting which can damage the printboard User s manual Railmaster SDC 5 Testing When the instructions as described in paragraphs 5 1 and 5 2 are executed the Railmaster can be tested and used according to the following steps 1 2 Close the door Move the driving belt with the mounting unit in such a way that the 50 mm position sticker which detects the closing position is in front