Home
Qubino - Domotique-Info
Contents
1. mono stable push button e 5 External relay control bi stable switch Parameter no 10 Activate deactivate functions ALL ON ALL OFF Available configuration parameters data type is 2 Byte DEC e default value 255 e 255 ALL ON active ALL OFF active e 0 ALL ON is not active ALL OFF is not active e 1 ALLON is not active ALL OFF active e 2 ALLON active ALL OFF is not active Smart meter module responds to commands ALL ON ALL OFF that may be sent by the main controller or by other controller belonging to the system Parameter no 11 Automatic turning off IR external relay output after set time When IR external relay is ON it goes automatically OFF after time defined by this parameter Timer is reset to zero each time the module receive ON command regardless from where it comes push button associated module controller Available configuration parameters data type is 2 Byte DEC e default value 0 e 0 Auto OFF disabled e 1 32535 1second 32535 seconds Auto OFF enabled with define time step is 1s Parameter no 12 Automatic turning on IR external relay output after set time When IR external relay is OFF it goes automatically ON after time defined by this parameter Timer is reset to zero each time the module receive OFF command regardless from where it comes push button associated module controller Available configuration parameters data type is 2 Byte DEC e
2. Type connection single phase 1b Reference current Iref 5A Maximum current Imax 65A Minimum current Imin 0 25 A Starting current 20 mA Voltage Un 230 V 20 Power consumption at Un lt 2W Nominal frequency fn 50 and 60 Hz Accuracy Active energy and power Standard EN 62053 21 class 1 Standard EN 50470 3 class B Reactive energy Standard EN 62053 23 class 2 Optical communication Type IR used to control BICOM432 40 IR Input 1 Rated voltage 230 V 20 Input resistance 450 kOhm Safety Indoor meter yes Degree of pollution 2 Protection class II AC voltage test 4 kV Installation Category 300 Vrms cat III Standard EN 50470 Ambient conditions and EMC According standards for indoor active energy meters Temperature and climatic condition according to EN 62052 11 Ambient conditions and Safety According standards for indoor active energy meters Temperature and climatic condition according to EN 62052 11 Dust water protection IP20 Operating temp range 10 40 C Storage temp Range 40 70 C Enclosure material self extinguish complying UL94 V Indoor meter yes Degree of pollution 2 AC voltage test 4 kV Standard EN 50470 Wireless range up to 30 m indoors depending on building materials Weight 150g Colour RAL 7035 EC Directives conformity EC Directive on Meas Instruments 2004 22 EC EC Directive on EMC 2004 108 EC EC Di
3. default value 0 e 0 Auto ON disabled e 1 32535 1second 32535 seconds Auto ON enabled with define time step is 1s Parameter no 13 Automatic turning off External relay output after set time When External relay is ON it goes automatically OFF after time defined by this parameter Timer is reset to zero each time the module receive ON command regardless from where it comes push button associated module controller Available configuration parameters data type is 2 Byte DEC e default value 0 e 0 Auto OFF disabled e 1 32535 1second 32535 seconds Auto OFF enabled with define time step is 1s Parameter no 14 Automatic turning on External relay after output set time When External relay is OFF it goes automatically ON after time defined by this parameter Timer is reset to zero each time the module receive OFF command regardless from where it comes push button associated module controller Available configuration parameters data type is 2 Byte DEC e default value 0 e 0 Auto ON disabled e 1 32535 1second 32535 seconds Auto ON enabled with define time step is 1s Parameter no 40 Power reporting in Watts on power change Set value means percentage set value from 0 100 0 100 Available configuration parameters data type is 1 Byte DEC e default value 10 e 0 Reporting disabled e 1 100 1 100 Reporting enabled Power report is send push
4. Qubino The INNOVATIVE and SMALLEST Smart meter ORDERING CODE Z WAVE FREQUENCY ZMNHTA1 868 4 MHz ZMNHTA2 921 4 MHz ZMNHTA3 908 4 MHz ZMNHTA4 869 0 MHz ZMNHTAS5 916 0 MHz This Z Wave module is used intended for energy measurements in single phase electrical power network and can be used in residential industrial and utility applications Meters measure energy directly in 2 wire networks according to the principle of fast sampling of voltage and current signals A built in microprocessor calculates energy power and power factor from the measured signals The module can be controlled through Z wave network and it acts as repeater in order to improve range and stability of Z wave network It is designed to be mounted on DIN rail Installation e Before the installation disconnect power supply e Connect the module according to electrical diagram e Locate the antenna far from metal elements as far as possible e Do not shorten the antenna Danger of electrocution e Module installation requires a great degree of skill and may be performed only by a qualified and licensed electrician e Even when the module is turned off voltage may be present on its terminals Any works on configuration changes related to connection mode or load must be always performed by disconnected power supply disable the fuse Note Do not connect the module to loads exceeding recommended values Connect the module only in accordanc
5. _ASSOCIATION_GRP_INFO_V2 COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 COMMAND_CLASS_MARK COMMAND_CLASS_BASIC NOTE Endpoints are shown hidden by Parameter No 100 BASIC SET GET on root device is mapped to basic set get of both endpoints This product can be included and operated in any Z Wave network with other Z Wave certified devices from any other manufacturers All constantly powered nodes in the same network will act as repeaters regardless of the vendor in order to increase reliability of the network Important disclaimer Z Wave wireless communication is inherently not always 100 reliable and as such this product should not be used in situations in which life and or valuables are solely dependent on its function Warning Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new once the retailer is legally obligated to take back your old appliance for disposal at least for free of charge This user manual is subject to change and improvement without notice NOTE User manual is valid for module with SW version S1 SW version is part of P N Exampl
6. a2 Module Inclusion Adding to Z wave network e Connect module to power supply e auto inclusion works for about 5 seconds after connected to power supply or e press service button S for more than 2 second NOTE For auto inclusion procedure first set main controller into inclusion mode and then connect module to power supply Module Exclusion Reset from Z Wave network e Connect module to power supply e _ bring module within maximum 1 meter 3 feet of the main controller e enable add remove mode on main controller e press service button S for more than 6 seconds By this function all parameters of the module are set to default values and own ID is deleted If service button S is pressed more than 2 and less than 6 second module is excluded but Removing configuration parameters are not set to default values Association Association enables Smart meter module to transfer commands inside Z Wave network directly without main controller to other Z Wave modules Associated Groups Group 1 Lifeline group reserved for communication with the main controller 1 node allowed Configuration parameters Parameter no 7 Input 1 switch function selection Available configuration parameters data type is 1 Byte DEC e default value 4 e Odisabled e 21R external relay control mono stable push button e 3 IR external relay control bi stable switch e 4 External relay control
7. e P N ZMNHTAx H1S1P1 Qubino Goap d o o Nova Gorica Ulica Klementa Juga 007 5250 Solkan Slovenia E mail info qubino com Tel 386 5 335 95 00 Web www qubino com Ix Date 24 9 2015 Document Qubino_Smart meter user manual_V1 0_eng
8. e to the below diagrams Improper connections may be dangerous Ilt is recommended to use 65 A fuses for the line protection Package contents e Smart meter Electrical diagram 230VAC nr A Lo No J Qubino www qubino com Smart meter 0 25 5 65 A 230Vac 50 60Hz CI B 15 55 C AIMcez wr LED 1 O LED2 O 1imp Wh Made in EU S LSN I 1 2 4 5 Notes for the diagram LI Live input NI Neutral input Lo Live output No Neutral output 1 Input for IR external relay Ext relay 2 Neutral lead for input 4 Live lead for External relay output 5 Output for External relay max 3W S Service button used to add or remove module from the Z Wave network LED1 Green Power on solid no ID blinking slow 1s Inc Exc mode blinking fast 0 5s LED2 Yellow on output on any Yellow off outputs off both IR Output for IR external relay limp Wh Red Pulse rate Measurements Voltage V Current Power Active W Power Active total kWh Power Reactive var Power Reactive total kvarh Power Apparent total kVAh Power Factor PF External relays It is possible to connect two external relay to Smart meter module One controlled by built in optical IR communication port on the side second controlled by output on terminal 5 SMART METER BICOM432 40 IR IKD232 20 230V 230V AC 230V AC IR In 32A in 32A gt oo iil N ai
9. only when actual power in Watts in real time changes for more than set percentage comparing to previous actual power in Watts step is 1 NOTE if power changed is less than 1W the report is not send pushed independent of percentage set When reporting Watts module will automatically reports also V Voltage A Amperes Power factor kVar Reactive Power Parameter no 42 Power reporting in Watts by time interval Set value means time interval 0 32535 in seconds when power report is send Available config parameters data type is 2 Byte DEC e default value 300 power report in Watts is send each 300s e 0 Reporting Disabled e 1 32535 1 second 32535 seconds Reporting enabled Power report is send with time interval set by entered value When reporting Watts module will automatically reports also V Voltage A Amperes Power factor kVar Reactive Power Parameter no 45 Reset Power counters Available configuration parameters data type is 1 Byte DEC e default value 0 e Ono function e 1 reset counter 1 KWh e 2 reset counter 2 kVARh e 4 reset counter 3 kVAh e 15 reset ALL counters Parameter no 100 Enable Disable endpoints IR external relay and External relay Enabling IR external relay and External relay or both of them means that endpoint IR external relay and endpoint External relay or both will be present on UI Disabling them will res
10. rective on Low Voltage 2006 95 EC EC Directive WEEE 2002 96 EC Dimensional drawings 45 36 Z Wave Device Class ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_ALWAYS_ON GENERIC_TYPE_METER SPECIFIC_TYPE_WHOLE_HOME_METER_SIMPLE Z Wave Supported Command Classes COMMAND_CLASS_ZWAVEPLUS_INFO_V2 COMMAND_CLASS_BASIC COMMAND_CLASS_SWITCH_ALL COMMAND_CLASS_SWITCH_BINARY_V2 COMMAND_CLASS_METER_V4 COMMAND_CLASS_MULTI_CHANNEL_V4 COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2 COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_MARK COMMAND_CLASS_BASIC COMMAND_CLASS_SWITCH_BINARY Endpoint 1 IR external relay Device Class GENERIC_TYPE_SWITCH_BINARY SPECIFIC_TYPE_POWER_SWITCH_BINARY Command Classes COMMAND_CLASS_ZWAVEPLUS_INFO_V2 COMMAND_CLASS_BASIC COMMAND_CLASS_SWITCH_BINARY_V2 COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2 COMMAND_CLASS_MULTI_LCHANNEL_ASSOCIATION_V3 COMMAND_CLASS_MARK COMMAND_CLASS_BASIC Endpoint 2 External relay Device Class GENERIC_TYPE_SWITCH_BINARY SPECIFIC_TYPE_POWER_SWITCH_BINARY Command Classes COMMAND_CLASS_ZWAVEPLUS_INFO_V2 COMMAND_CLASS_BASIC COMMAND_CLASS_SWITCH_BINARY_V2 COMMAND_CLASS_VERSION_V2 COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS
11. ult in hiding endpoints according to parameter set value Note that hiding endpoint has no impact on its functionality Available configuration parameters data type is 1 Byte DEC e default value 0 e 0 Endpoints IR external relay and External relay disabled e 1 Endpoints IR external relay disabled External relay enabled e 2 Endpoints IR external relay enabled External relay disabled e 3 Endpoints IR external relay and External relay enabled NOTE After parameter change module has to be reconfigured Parameter no 130 Serial Number Read only Parameter no 131 Meter Software reference Read only Parameter no 132 Meter Hardware reference Read only Parameter no 140 Voltage U1 Read only Parameter no 141 Current I1 Read only Parameter no 142 Active Power Total Pt Read only Parameter no 143 Reactive Power Total Qt Read only Parameter no 144 Power Factor Total PFt Read only Parameter no 145 Energy Counter 1 Active power accumulated Read only Parameter no 146 Energy Counter 2 Reactive power accumulated Read only Parameter no 147 Energy Counter 3 Apparent power accumulated Read only Technical Specifications Main terminals Li Ni Lo No Contacts capacity 1 5 16 25 mm Connection screws M5 Max torque 3 5 Nm PZ2 Optional terminals 1 2 4 5 Contact capacity 0 05 1 2 5 mm Screws M3 Max torque 0 6 Nm Measuring input
Download Pdf Manuals
Related Search
Related Contents
Italian SMC Networks Switch SMC8848M User's Manual Samsung Galaxy Alpha manual do usuário(OPEN) Elation 15rPro Manuel d`atelier - Forum du Bateau Daewoo Electronics KOG-37DP0S User's Manual Whirlpool 3360464 Washer User Manual Untitled - Skylanders ASUS P1 Owner's Manual Installation Manual Copyright © All rights reserved.