AM-1016

image

Contents

1. 3digits AC CURRENT 200 uA 0 1 uA 2 0 of rdg 3 digits 1 0 of rdg 3 digits 200mA 100 uA 1 8 of rdg 3 digits Page 9 of 10 WWW TMATLANTIC COM Overload Protection F 200Ma 250V fuse for 200uA to 200mA ranges Frequency Range 40Hz to 400Hz for AC Response Average Calibrated in rms of sine wave 4 4 RESISTANCE 0 8 of rdg 3 digits 0 8 of rdg 2 digit 0 8 of rdg 2 digit 0 8 of rdg 2 digit 0 8 of rdg 2 digit 1 0 of rdg 2 digit 5 0 of rdg 10digits 10 digits Maximum Open Circuit Voltage 700mV 3V for200MQ range Note On 200MQ range if short input display will read 1 MQ this 1 MQ should be subtracted from measurement results Overload Protection 250V dc or 250V ac rms 4 5 DIODE CONTINUTY Range Description Diode Shows the approximate forward voltage drop Continuit Built in buzzer will sound if the resistance under test is less than about 700 Overload Protection 250V dc or 250V ac rms 5 BATTERY amp FUSE REPLACEMENT If the sign C appears on the LCD display it indicates that battery should be replaced Remove screws on the back cover and open the case see the right photo Replace the exhausted battery with a new one Page 10 of 10 WWW TMATLANTIC COM Fuse rarely need replacement and blow almost always as a result of the operator s error Open the case as mentioned above and then take the PCB out from the front cover Replace
2. A AKTAKOM Network Multimeter AM 1016 User s Manual www tmatlantic com Page 1 of 10 WWW TMATLANTIC COM 1 SAFETY INFORMATION M WARNING To ensure safe operation and in order to exploit to the full functionality of the meter please follow the directions in this section carefully This multimeter has been designed according to IEC 1010 concerning electronic measuring instruments with an over voltage category CAT II 1000V CAT III 600V and pollution2 With proper use and care the digital multimeter will give you years of satisfactory service Follow all safety and operating instructions to ensure that the meter is used safely and is kept in good operating condition 1 1 PRELIMINARY 1 1 1 When using the meter the user must observe all normal safety rules concerning e Protection against the danger of electrical attack e Protection of the meter against misuse 1 1 2 When the meter is delivered check if it has been damaged in transit 1 1 3 When harsh preservation or shipping conditions caused inspect and confirm this meter without delay 1 1 4 Test leads must be in good condition Before using verify that the insulation on test leads is not damaged and or the leads wire is not exposed 1 1 5 Full compliance with safety standards can be guaranteed only id used with test leads supplied If necessary they must be replaced with the same model or the same class 1 2 DURING USE 1 2 1 Never exceed the
3. the blown fuse with same ratings Battery cover A WARNING Before attempting to open the case be sure that test leads have been disconnected from measurement circuits to avoid electric shock hazard For protection against fire replace fuse only with specified ratings F 200mA 250V
4. MISWIRE Fig 3 REVERSED CONMROWNM BONMOBDWH DONOR QUN ONNA OWN ONO DWH Fig 4 SPLIT PAIRS Fig 5 RIGHT PASS ONOMPOWN DONMAPDWNH ONE OWN ONJIA QON ONS OWN Page 7 of 10 WWW TMATLANTIC COM 3 7 1 Connect the RJ45 test jack to one end of the cable to be tested 3 7 2 Connect the remote unit to the other end of the cable 3 7 3 Push TEST button to perform test Example The Cable Fault is a SHORT on Pair 1 2 and Pair 3 6 the LCD status will be as follows Pair 1 2 Pair 3 6 Pair 4 5 Pair 7 8 SHIE and SHO will display at the same time 3 7 4 Push TEST button again Pair 1 2 Pair 3 6 and SHO will display Continue to Push TEST button the next pairs will display 4 SPECIFICATIONS Accuracy is specified for a period one year after calibration and at 18 C to 28 C 64 F to 82 F with relative humidity to 80 4 1 GENERAL 0 C to 40 C 32 F to 104 F STORAGE TEMPERATURE 10 C to 50 C 14 F to 122 F DIMENSION 185 x 85 x 44 mm WEIGHT 360 g 4 2 VOLTAGE DC VOLTAGE 200m V 0 1mV 2V ImvV _ 0 8 of rdg 2 digits 200V 100mV 1000V 1 2 of rdg 3 digits Page 8 of 10 WWW TMATLANTIC COM AC VOLTAGE 200mV 1 2 of rdg 3digits 2 V ImvV 20V 0 8 of rdg 3 digits Input Impedance 10MQ Frequency Range 40Hz to 400Hz for AC Response Average calibrated in rms of sine wave 4 3 CURRENT DC CURRENT ccumnewr O 10 8 of rdg
5. ct the RJ11 test jack to one end of the telephone line to be tested 3 6 2 Connect the UAX Telephone Unit Automatic Exchange to the other end of the line 3 6 3 Push TEST button to perform test 3 7 TESTING Network Cable RJ45 CAUTION DO NOT use on the circuits as it may damage the tester e The network tester is suitable for T168A T568B 10Base T and Token Ring Page 6 of 10 WWW TMATLANTIC COM The Network Cable Tester will check a fault condition in the above descending order before detecting other fault conditions The detection and indication of the presence of a fault is handled on a one per test basis Once a fault is corrected it is recommended the cable be tested again for other faults OPEN There is no OPEN indication A typical cable may have 2 3 or 4 pairs OPENS are displayed as an unlit symbol The user will determine if a pair is present and continuous or OPEN by comparing the illuminated symbol to the expected number of pairs that should be good SHO A short circuit condition exists see Fig 1 MIS Indicates the improper assignment of individual wire pairs to pins for the wiring schemes tested see Fig 2 REV Reverse wiring means the pin for one wire in a pair is connected to the opposite pin for the pair in the remote jack see Fig 3 SPL Split pairs occur when the tip positive conductor and ring negative conductor of two twisted pairs are interchanged see Fig 4 Fig 1 SHORT Fig 2
6. ecified voltage and current ratings F 200mAI250V quick acting 1 4 5 Do not use abrasives or solvents on the meter use a damp cloth and mild detergent only 1 4 6 ALWAYS set the power switch to the OFF position when the meter is not in use 1 4 7 If the meter is to be stored for a long period of time the batteries should be removed to prevent damage to the unit Page 3 of 10 2 DESCRIPTION WWW TMATLANTIC COM The 3 in 1 digital multi tester has been designed to combine the functions of Digital Multimeter Telephone Line Tester and Network Cable Tester DC voltage measurement 5 ranges from 200mV to 1000V AC voltage measurement 5 ranges from 200mV to 700V DC AC current measurement 5 ranges from 200MA to 10A Resistance measurement 7 ranges from 2000 to 200MQ e Diode test Audible continuity test Battery test 1 5 6 9V Telephone Line test RJ11 o Network Cable test RJ45 3 OPERATING INSTRUCTION 3 1 MEASURING VOLTAGE Names of components 1 RJ 11 test jack 2 RJ45 test jack 3 Data hold key only for multimeter 4 AC DC switch key 5 8 input jacks 9 RJ45 jack Remote 10 Function range select rotary switch 11 Cable test key Resent 12 Back light key 13 LCD display 3 1 1 Connect the black test lead to the COM jack and the red test lead to the V Q jack Page 4 of 10 WWW TMATLANTIC COM 3 1 2 Set the rotary switch at the desired V range pos
7. ing The meter will show the approx Forward voltage drop of the diode If the lead connection is reversed only figure 1 will be displayed If continuity exists i e resistance less than about 70Q built in buzzer will sound 3 4 MEASURING RESISTANCE Page 5 of 10 WWW TMATLANTIC COM 3 4 1 Connect the black test lead to the COM jack and the red test lead to the V Q jack NOTE The polarity of red lead connection is positive 3 4 2 Set the rotary switch at desired Q range position and connect test leads across the resistance under measurement Read LCD display NOTE 1 For resistance above 1 MQ the meter may take a few seconds to stabilize reading 2 When the input is not connected i e at open circuit the figure 1 will be displayed for the overrange condition 3 When checking in circuit resistance be sure the circuit under test has all power removed and all Capacitors are full discharged 4 At 200MQ range display is 10 counts when test leads are shorted These counts have to be subtracted from measuring results For example when measuring 100M Q resistance the reading will be 101 0 and the correct measuring result should be 101 0 1 0 100 0 MO 3 5 TESTING BATTERY 3 5 1 Connect the black test lead to the COM jack and the red test lead to the V Q jack 3 5 2 Set the rotary switch at the desired BAT range position and connect test leads across the battery 3 6 TESTING Telephone Line RJ11 3 6 1 Conne
8. ition and connect test leads across the source or load under measurement 3 1 3 Put down the AC DC when measuring the voltage Meter will be transformed between DC and AC range 3 1 4 If you need data hold when measuring you can put on HOLD it will hold the reading if you put the button again data hold will not continue 3 1 5 When only the figure 1 is displayed it indicates over range situation and the higher range has to be selected 3 2 MEASURING CURRENT 3 2 1 Connect the black test lead to the COM jack and the red test lead to the A jack for a maximum of 200mA For a maximum of 10A move the red lead to the 10A jack 3 2 2 Set the rotary switch at desired A range position and connects test leads in series with the load under measurement 3 2 3 Put down the AC DC when measuring the current Meter will be transformed between DC and AC range 3 2 4 If you need data hold when measuring you can put on HOLD it will hold the reading if you put the button again data hold will not continue 3 2 5 When only the figure 1 is displayed it indicates over range situation and the higher range has to be selected 3 3 TESTING DIODE CONTINUITY 3 3 1 Connect the black test lead to the COM jack and the red test lead to the V Q jack NOTE The polarity of red lead connection is positive 3 3 2 Set the rotary switch at P position and connect the red lead to the anode the black lead to the cathode of the diode under test
9. protection limit values indicated in specifications for each range of measurement 1 2 2 When the meter is linked to measurement circuit do not touch unused terminals Page 2 of 10 WWW TMATLANTIC COM 1 2 3 When the value scale to be measured is unknown beforehand set the range selector at the highest position 1 2 4 Before rotating the range selector to change functions disconnect test leads from the circuit under test 1 2 5 When carrying out measurements on TV or switching power circuits always remember that there may be high amplitude voltages pulses at test points which can damage the meter 1 2 6 Never perform resistance measurements on live circuits 1 2 7 Always be careful when working with voltages above 60V dc or 30V acrms Keep fingers behind the probe barriers while measuring 1 3 SYMBOLS AN Important safety information refer to the operating manual CE European Union Directive Earth Ground 1 4 MAINTENANCE 1 4 1 Please do not attempt to adjust or repair the meter by removing the rear case while voltage is being applied A technician who fully understands danger involved should only carry out such actions 1 4 2 Before opening the case of the meter always disconnect test leads from all sources of electric current 1 4 3 To avoid the wrong reading causing electricity attack when the meter displays ak you must change the battery 1 4 4 For continue protection against fire replace fuse only with the sp

Download Pdf Manuals

image

Related Search

AM 1016 am 1016 z5053 am1016a am101615 am101602 john deere am1016b am 1160 radio am 116304 fuel filter am 1160 hope for your life am 1160 am 1160 hope am 1160 in ithaca am 1160 olavarria am 1160 atlanta am 1160 chicago

Related Contents

Whirlpool LA50000XP User's Manual  Fujitsu PRIMERGY TX200 S4  2 - シャープ  INSTRUCCIONES DE USUARIO  JTCー。ーー ー ー533 クランクシャフ ト固定レンチ取扱説明書  Service Manual – ThermoPro Single Head Brewer  入札説明書 - JICA  Procesamiento de Papaya a Pequeña Escala, Elaboración  Barfield DPS 450 Manual  AFT - MTE Prof. Danillo Lorusso Seg. e Saúde no Trabalho  