1. McMaster Innovation Park 175 Longwood Rd South Suite 114A Hamilton ON L8P 0A1 CANADA P 1 905 481 2607 EnviroSim ee ASSOCIATES LTD www envirosim com Installing PetWin 3 under Windows 7 1 Installing PetWin when BioWin is already installed PetWin 3 will be installed in a separate directory from BioWin Note that this upgrade will not affect BioWin versions which are separate applications This means that users can run their copies of BioWin in parallel with PetWin Installation Note 1 Do NOT plug the Hardlock Aladdin key into your computer until the installation is complete Note 2 You must have Administrator privileges to install the software Installation from CD e Insert the CD into the CD drive Installation should start automatically e If installation does not begin after several seconds e Open a command prompt click START button type command prompt into the search field and click on command prompt in the selection window e Type D PW31SETUP exe if your CD drive is another letter replace D with that letter Click OK to start installation e Follow the instructions on the screen Installation from downloaded file e Goto the download location e Double click on PW31SETUP exe e Follow the instructions on the screen Hardlock After installation and every time you want to run PetWin you must plug the Hardlock Aladdin key into your PC see picture below Hardlock key fo
2. user defined state variable concentrations metal addition for chemical phosphorus precipitation ferric or alum methanol for denitrification e Other process modules holding tanks equalization tanks dewatering units flow splitters and combiners A crucial component of PetWin is the biological process model The PetWin model is unique in that it merges both activated sludge and anaerobic biological processes Additionally the model integrates pH and chemical phosphorus precipitation processes It s easy to use The program has the look and feel of the many other Windows applications When it is launched it comes up with the familiar interface and menu structure Complex treatment plant schemes can be configured rapidly through drag and drop mouse actions Functions are selected from the pull down menus using short cut keys or by pointing the mouse and clicking on icons in the toolbar The user can also access many of the Windows functions usually embedded in a Windows application for example selecting and configuring the printer setup Context sensitive Help is built into PetWin to provide on line assistance particularly for new users Careful consideration has gone into the design of the package for example the hardware and software platforms the object oriented software development system the data structures the user interface and so on A primary aim has been the production of a package structured to allow on going devel
3. then the hardware should be functioning correctly and it is likely that your problem is not related to the installation of your key PetWin Hardlock key messages PetWin error message Possible reasons Error Unable to find Key OR All network licenses in use 1 The key is not plugged in or could not be found 2 The key driver software is not properly installed 3 If you have a server version of the software then either the Hardlock server cannot be found or all the licenses are in use Error Network error 1 If you do not have the server version then key cannot be found 2 If you have a server version of the software then an error in network operation remote was detected This may occur for example if no protocol such as IPX or NetBios is loaded in the local client system Error Accessing required driver A required driver cannot be opened The problem is usually that the driver is not installed Error Too many users The maximum number of users has been reached Error Invalid environment settings The specified environment variable for the API search sequence contains only incorrect entries Error Version mismatch HLVDD DLL During communication the system determined that the HARDLOCK VXD or HARDLOCK SYS HL Server or an installed Hardlock driver is not compatible with the API version being used PetWin Lease Messages Possibl
4. Environment Variables in the document hlendusersmanual_en pdf located in the MANUAL directory on the installation CD ROM describes the use of environment variables PetWin 3 Created by process engineers for process engineers Features of PetWin PetWin is a completely new version of the PetWin simulation tool for wastewater treatment for the petroleum and petrochemical industry PetWin features the state of the art model ASDMi which now includes sulfur species and processes on top of all other treatment related components and processes PetWin uses the well known BioWin simulator technology and even allows opening files developed in BioWin PetWin in Brief The user can define and analyze behavior of complex treatment plant configurations with single or multiple petrochemical and other wastewater inputs An example of a plant configuration is shown below Most types of petroleum and petrochemical wastewater treatment systems can be configured in PetWin using the many process modules These include e Arange of activated sludge bioreactor modules suspended growth reactors diffused air or surface aeration various SBRs media reactors for IFAS and MBBR systems variable volume reactors e Anaerobic and aerobic digesters e Various settling tank modules primary ideal and 1 D model settlers e Different input elements industrial influent COD based other wastewater influent COD or BOD baseqd
5. e Reasons LEASE EXPIRED Your lease period has come to an end contact EnviroSim for a lease renewal Your PetWin lease will expire in X days Contact EnviroSim to renew your lease now Your lease will expire in the specified number of days Your PetWin lease was successfully updated The lease code that you entered was accepted by PetWin and your lease date has been updated Your PetWin lease was successfully updated An updated version is available The lease code that you entered was accepted by PetWin and your lease date has been updated A minor update of the PetWin software is available Code appears to be mistyped please check The code that you entered is incorrect for the key that you are using or has been mistyped Program file appears corrupted The PetWin executable file appears to be corrupt please contact EnviroSim Purchased version PetWin Code entered for older version The activation code entered is only valid for the version of PetWin purchased Please contact Envirosim Hardlock key search information If your system has difficulties in finding the Hardlock key there are a number of environment variables that can be used to address these difficulties The environment variables allow you to specifically use the port on which the key is installed change the network search options and control retries and timeouts The section Setting
6. opment in years to come The PetWin simulator suite presently includes two modules e A steady state module for analyzing systems based on constant influent loading and or flow weighted averages of time varying inputs This unit is also very useful for mass balancing over complex plant configurations e An interactive dynamic simulator where the user can operate and manipulate the treatment system on the fly This module is ideal for training and for analyzing system response when subjected to time varying inputs or changes in operating strategy Linking to PW Controller PW Controller is a separate Windows application which links to a PetWin configuration and allows specification of a range of process control features commonly employed in wastewater treatment systems Start PW Controller To start click on the Start PW Controller button at the right on the toolbar in PetWin to link the control application to the PetWin configuration PW Controller includes its own Help and Tutorials
7. r PetWin The Hardlock USB is equipped with an LED which shows the status of the protection module If you plug the Hardlock key into the USB port the LED does not light up or if it flashes see the section Hardlock USB key status information in Appendix 1 4 Lease Activation Code When you first run PetWin after installing you will be prompted to enter a Lease Activation Code This is located on a sticker on the back of the CD case Type the code in and press the Apply Lease Code button note that the code is NOT case sensitive Note A common error is pressing the OK button instead of the Apply Lease Code button 5 Help F1 PetWin employs the latest in Help delivery technology HTML help This launches with a look and feel consistent with Microsoft Office products For tips on using this effectively look in the Help press the F1 button under the Getting Help in PetWin chapter 6 Manual PetWin does not ship with a printed manual However if you want to print the manual it has been shipped as an Adobe PDF This document can be found on your PC in the MISC subdirectory of your PetWin installation directory the standard path is C PROGRAM FILES ENVIROSIM PETWIN 3 1 MISC but depends on where you installed 7 Getting started A good starting point is to print out the Tutorials chapter and use this to get familiar with PetWin It s all in the Help but having a hardcopy may be easier for the initial steps Afte
8. r you install there is a document called Help Tutorials amp Examples PDF in the MISC subdirectory of the PETWIN 3 directory Alternatively look on the CD in the MANUAL directory Running PetWin 3 To run PetWin click the PetWin shortcut in the Start menu PetWin 32v1 J PetWin 3 1 C Help Tutorials amp Examples PetWin Feature Tour iz oa PetWin 3 1 4 Back Appendix 1 Hardlock information General The Aladdin Hardlock End User s Manual is in the document hlendusersmanual_en pdf which is located in the MANUAL directory on the installation CD ROM The document contains detailed information about the Hardlock module installations procedures and troubleshooting information If you have purchased a server version of the software the document also describes the HL Server and utility software Hardlock USB key status information Hardlock USB is equipped with an LED display which shows the status of the protection module LED display Status LED does not light The module is not recognized Possible reasons No driver no USB support module not functioning LED flashes at approx 2 Hz The module is recognized but not initialized correctly Possible reasons Memory defective module not encoded as a Hardlock module module not functioning LED lights up The module is recognized and initialized correctly If your USB key LED is steadily lit