image

Contents

1. User s Manual Lineage LI2200 UPS K01 1120004 00 LEGACY TABLE OF CONTENTS IMPORTANT SAFETY WARNINGS 0 0 ce cece e eee eee e eee eee e eee eae ee ees 1 INSTALLING YOUR UPS SYSTEM 00 ccc cceceee cece ee eee eee eee ee ee eeeeeeeeeeeeeeeees 2 UNPACKING coses eshte eles ces saeetect nc eles we wee wea ee eee 2 HARDWARE INSTALLATION GUIDE 0 0 cece cece eee eee eee ees 2 FRONT PANEL DESCRIPTION eceeesecceecceeeee eee eeeeeenesseaeeeeeeeeeeeneeeens 3 REAR PANEL DESCRIPTION viecpececeuets irosen arendsi 4 BATTERY REPLACEMENT AND STORAGE cc ccceeeee cece eee eee e eee eeeee tees 6 BATTERY REPLACEMENT PROCEDURE 0 eeeeeeeettetteeeeeeee es 7 DEFINITION FOR ILLUMINATED LED INDICATORS 8 TROUBLESHOOTING osiinsa ee eae Sra aaa 9 TECHNICAL SPECIFICATIONS 00 cc cece cece eee eee ee eee e teeta eee eereneas 10 LIMITED WARRANTY cennin a eerie eevee 11 Thank you for purchasing a Legacy Power Conversion Product To enjoy all the features and benefits of this Uninterruptible Power System UPS please read and follow all installation and operation instructions completely This UPS is designed to provide guaranteed power protection for connected electronic equipment The accompanying SeeUPS2020 software saves data closes open applications and automatically shuts down your computer system in an intelligent and orderly manner
2. On Off os On Off Flash On Off p ae Off On Off Set Up Condition AVR Max boost 15 of input voltage for output regulation while input voltage is from 8 to 30 under nominal AVR Max buck 15 of input voltage for output regulation while input voltage is from 8 to 26 over nominal Utility Failure The UPS is providing battery power to the Battery Power Supplied outlets Utility Failure The UPS is providing battery power Rapid beeps indicate the battery will run out of charge within a few minutes Overload Turn the UPS off and unplug at least one piece of equipment from the UPS Wait 5 seconds reset the circuit breaker and restart the UPS Overload Turn the UPS off and unplug at least one piece of equipment from the UPS Wait 5 seconds reset the circuit breaker and restart the UPS Weak Battery Recharge the battery for at least 8 hours If Check Battery is illuminated contact Legacy Power Conversion for battery replacement information Surge Protection Malfunction Power surge has damaged the unit Please contact Legacy Power Conversion Electrical Wiring Fault Indicates wiring problems such as a bad ground missed ground or reversed wiring within the AC outlet User is advised to disconnect all electrical equipment from the outlet and have the outlet checked by an electrician Lineage LI2200 Uninterruptible Power System TROUBLESHOOTING Problem Possible Cause Solution Turn the
3. Lineage LI2200 Uninterruptible Power System IMPORTANT SAFETY WARNINGS SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation and maintenance of the UPS and batteries Please read and follow all instructions carefully during installation and operation of the unit Read this manual thoroughly before attempting to unpack install or operate CAUTION The UPS must be connected to an AC power outlet with fuse or circuit breaker protection DO NOT plug the machine into an outlet that is not grounded If you need to de energize this equipment turn off and unplug the UPS CAUTION DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT Legacy Power Conversion does not sell products for life support or medical applications DO NOT use in any circumstance that would affect operation or safety of any life support equipment with any medical applications or patient care CAUTION The battery can energize hazardous live parts inside even when the AC input power is disconnected CAUTION To prevent the risk of fire or electric shock install in a temperature and humidity controlled indoor area free of conductive contaminants Please see specifications for acceptable temperature and humidity range CAUTION To reduce the risk of electric shock do not remove the cover except to service the battery No user serviceable parts inside except for the battery CAUTION To avoid electrical shoc
4. UPS off and unplug at Circuit breaker is tripped least one piece of equipment due to overload Wait 10 seconds reset the circuit Outlets do not breaker and then turn the UPS on provide power to equipment Recharge the unit for at least 4 hours Unit has been damaged by Recharge the battery by leaving a surge or spike the UPS plugged in Bater isnot lly charaed Recharge the battery by leaving The UPS does y y ged the UPS lugged in not oe Contact Legacy Power Conversion expecte a about replacement batteries at runtime Battery is slightly worn out A besos con or 800 859 5711 Batteries are discharged The on off switch is designed to prevent Turn the UPS off Wait 10 seconds damage by rapidly turning and then turn the UPS on it off and on l The unit is not connected to The unit must be connected to a The UPS will an AC outlet 110 120v 60Hz outlet not turn on Contact Legacy Power Conversion about replacement batteries at The battery has failed service lpc ups com or 800 859 5711 Contact Legacy Power Conversion Mechanical problem at service lpc ups com or 800 859 5711 Connect the serial cable to the The serial cable is not UPS unit and an open serial port of connected your computer You must use the cable that came with the unit The serial cable is SeeUPS2020 connected to the wrong Try ae port of your seca puter is inactive all port ICONS are Shutdown your computer and turn gray The unit i
5. end user referred to as the Initial Customer receives an express limited warranty referred to as the Limited Warranty for the LI2200 purchased from Legacy referred to as the Product The Limited Warranty is for the Product itself The Limited Warranty is subject to the terms set forth below Additionally State or Provincial law may adjust the terms of the Limited Warranty or the State or Province may impose additional obligations or additional implied warranties To the extent necessary to comply with those laws the terms of the Limited Warranty should be read to adjust to those requirements only to the extent necessary to comply with such local law If you are an Initial Customer you are asked to read the following terms and conditions carefully before using the Product By using the Product you consent to be bound by and become a party to the Limited Warranty If you do not agree to the terms and conditions of the Limited Warranty you should return the Product for a full refund prior to using it REGISTRATION Legacy requests that you complete and return the Warranty Registration Card enclosed with the Product or register the Product at its website www pc ups com to establish that you are the Initial Customer of the Product and therefore entitled coverage under the Limited Warranty Registration is not required for Limited Warranty coverage but note if you do not complete a registration card you will be required to provide pro
6. to the operation of the UPS The Secondary computer with SeeUPS2020 installed is unable to exhibit any control over the UPS When there is a power failure the Primary computer will start to shutdown after a user controlled delay Once the Primary computer is shutdown the UPS will signal the secondary computer and initiate a shutdown The secondary computer will then shutdown Once the secondary computer has completed its shutdown the UPS will power off SeeUPS2020 will save and close any open files prior to shutting the system down Serial Port Serial Port Il Y dary g 3 m a a S Cag F e a Z Primary Computer Secondary Computer install SeeUPS2020 Plus Install SeeUPS2020 LEGACY BATTERY REPLACEMENT Contact your dealer or call the number in this manual for information on battery replacement The order numbers for the battery assembly are BBAT LI2200 for LI2200 Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery Service the battery under the supervision of personnel knowledgeable of batteries and their precautions Servicing the battery can only be performed by trained personnel CAUTION Use only the specified type of battery See your dealer for replacement batteries CAUTION The battery may present the risk of electrical shock Do not dispose of batteries in a fire as they may explode Follow all local ordinances regarding proper disposal of batteries CAUTION Do not open or mut
7. Itis essential that only the supplied power cord be used Use only shielded cables to connect I O devices to this equipment CAUTION Any changes or modifications not expressly approved by the guarantee of this device could void the user s authority to operate the equipment LEGACY For more information contact us at Legacy Power Conversion Inc N9246 Hwy 80 South Suite 7 Necedah WI 54646 Tel 800 859 5877 Fax 608 565 5879 Email sales lpc ups com Web www lpc ups com Entire contents copyright 2006 Legacy Power Conversion Inc All rights reserved Reproduction in whole or in part without permission is prohibited
8. a wiring problem exists WARNING within the AC receptacle such as a bad ground miss ground or reversed wiring If illuminated disconnect all equipment and contact an electrician to insure outlet is properly wired Battery Indicator This illuminates during utility failure indicating that the battery is USING supplying power to the battery power supplied outlets aoe Cin pplying p y p pp AVR Indicator This LED indicates that the UPS is operating in automatic voltage AR OQO regulation mode When the led is illuminated continuously it indicates input over voltage and the UPS unit bucks the voltage When the led is flashed in rotation it indicates that the UPS unit boosts input voltage Power On Indicator This LED is illuminated when the utility condition is normal and the vs Q mN UPS outlets are providing clean power free of surges and spikes E LEGACY Battery Indicators This indicator shows a visual indication of the battery charge If battery capacity is under 20 no indicator LED will illuminate and UPS starts e beeping part a Load Level Indicators E This indicator shows a visual induction of the UPS load The load indicator LED will turn orange if the load is between 80 and 100 If the load is i under 20 no indicator LED will illuminate o E A oan REAR PANEL DESCRIPTION Tete Ne WGA TH UOH OM ae a om Wedd Me PO 18 v1 Ge FIR Standardan FoR HONE Of OFFICE a ci
9. d the unit will emit one long beep To correct this turn the UPS off and unplug at least one piece of equipment from the battery power supplied outlets Wait 10 seconds Make sure the circuit breaker is depressed and then turn the UPS on If an overload is detected an audible alarm will sound and the unit will emit one long beep To correct this turn the UPS off unplug at least one piece of equipment wait 10 seconds check to make sure that the circuit breakers are depressed and turn the unit on Your UPS is equipped with an auto charge feature When the UPS is plugged into an AC outlet the battery will automatically recharge 2 Lineage LI2200 Uninterruptible Power System 9 To maintain optimal battery charge leave the UPS plugged into an AC outlet at all times 10 To store your UPS for an extended period cover it and store with the battery fully charged Recharge the battery every three months to insure battery life BASIC OPERATION FRONT PANEL DESCRIPTION Power Switch Press the power button to turn the UPS ON or OFF Test Switch Lineage LI2200 UPS performs a self test automatically When powered on When the UPS passes the test it returns to on line operation If the L d UPS fails the self test please recharge the battery for hours and perform another self test If it fails after recharging the battery please replace the battery Wiring Fault Indicator This LED will illuminate to warn the user that
10. eplace the Product if defective within a reasonable time Legacy will refund to you the full purchase price you paid for the Product purchase receipt showing price paid is required CONDITIONS TO THE LIMITED WARRANTY The Limited Warranty is the only and the exclusive express warranty of Legacy with respect to the Product This exclusion of other express warranties applies to written and oral express warranties LIMITATION THE LIMITED WARRANTY DOES NOT COVER The Limited Warranty is intended to exclusive rights and remedies and replace any other rights to the extent allowed by law As to the Legacy Product the limited warranty does not cover or apply to misuse modification operation or storage outside environmental limits for the Products in transit in shipment or in storage damage or deterioration improper operation or maintenance or use with items or equipment not designed or intended for use with the product The Limited Warranty Does Not Apply Unless The Initial Customer 1 Has properly connected the Product and the Connected Equipment to properly wired and grounded outlets including compliance with electrical and safety codes of the most current electrical code ANS NFPA 70 without the use of any adapters extension cords of other connectors 2 Has provided a suitable and proper environment for use and installation of the Product and Connected Equipment 3 Has properly installed and operated the Legacy Product and Con
11. gs OUT Circuit Breaker Reset for Overload Protection go ae Resettable circuit breakers provide optimal overload protection Battery Backup and surge Protection Outlets T E S The UPS provides four battery powered surge protected and a gD f AVR outlets for connected equipment and insures temporary Os uninterrupted operation of connected equipment during a jam a power failure Individual Backup Power for Critical Load The UPS provides two battery powered surge protected and AVR outlets for the most critical connected equipment and insures temporary uninterrupted operation of connected equipment during a power failure NOTE When the the UPS is overloaded two circuit breakers will be tripped to interrupt power supply to the four battery outlets and leaves the two outlets for critical loads uninterrupted peg m Our O j Dan ihe TEA Lineage LI2200 Uninterruptible Power System Communication Protection Ports RJ11 RJ45 Ports protect standard modem fax telephone line or network cable Dual Serial Ports Lineage LI2200 UPS provides two serial ports to allow connection 5 ole s innti j i lin and communication between the UPS and two computers This Serial Port Serial Port I PRIMARY allows the simultaneous shutdown of two computer systems The Primary computer with SeeUPS2020 Plus installed is the computer that you will use to control the UPS and make any changes
12. ilate the batteries Release electrolyte is harmful to the skin and eyes and may be toxic CAUTION A battery can present a high risk of short circuit current and electrical shock Take the following precautions before replacing the battery 1 Remove all watches rings or other metal objects 2 Only use tools with insulated handles 3 Do not lay tools or metal parts on top of battery or any terminals 4 Wear rubber gloves and boots 5 Determine if the battery is inadvertently grounded If inadvertently grounded remove source of ground CONTACT WITH GROUNDED BATTERY CAN RESULT IN ELECTRICAL SHOCK The likelihood of such shock will be reduced if such grounds are removed during installation and maintenance applicable to a UPS and a remote battery supply not having a grounded circuit Lineage LI2200 Uninterruptible Power System BATTERY REPLACEMENT PROCEDURE 1 Remove the right side front panel 3 Disconnect the black and red cable 5 Pull the battery pack out from the unit 2 Remove the two retaining screws of the cable protection cover then remove the cover E 4 Remove the four retaining screws 6 Slide a new battery pack into the unit Assemble the screws cover cable and front panel in the reverse sequence of above steps 7 Recharge the unit for 4 8 hours to ensure the UPS performs expected runtime LEGACY DEFINITIONS FOR LED INDICATORS On Off On Off On Off IFlash On Off
13. k turn off the unit and unplug it from the AC power source before servicing the battery or installing a computer component CAUTION DO NOT USE WITH OR NEAR AQUARIUMS To reduce the risk of fire do not use with or near aquariums Condensation from the aquarium can come in contact with metal current contacts and cause the machine to short out CAUTION DONOT USE WITH LASER PRINTERS The power demands of laser printers are too large for a UPS LEGACY INSTALLING YOUR UPS SYSTEM UNPACKING Inspect the UPS upon receipt The box should contain the following 1 UPS Unit 1 User s Manual for UPS 2 Rack mount Brackets 2 Stands 1 Telephone Cable 1 SeeUPS2020 Software Disk 1 User s Manual for SeeUPS2020 2 Serial Interface Cable DB 9 1 Serial to USB cable 1 Warranty Registration Card HARDWARE INSTALLATION GUIDE 1 N Your new UPS may be used immediately upon receipt However recharging the battery for at least four hours is recommended to insure that the battery s maximum charge capacity is achieved Charge loss may occur during shipping and storage To recharge the battery simply leave the is unit plugged into an AC outlet The unit will charge in both the on as well as lif yt the off position A i If you wish to use the software connect the enclosed serial interface cable to the serial port on the UPS and an open serial port on the computer If you would like to use USB interface please connec
14. ll free Legacy is the warrantor under this Limited Warranty You may also contact Legacy on the Internet at www lpc ups com E LEGACY FCC Notice This equipment has been tested and found to comply with the limits for a Class B Digital Device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures 1 Reorient or relocate the receiving antenna 2 Increase the separation between the equipment and receiver 3 Connect the equipment into an outlet on a circuit different from that to which the receiver is connected 4 Consult the dealer or an experienced radio TV technician for help Any special accessories needed for compliance must be specified in the instruction CAUTION A shielded type power cord is required in order to meet FCC emission limits and also to prevent interference to the nearby radio and television reception
15. mage or loss is caused by negligence or other fault NOTE Some States or Provinces do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you DO NOT USE FOR HIGH RISK ACTIVITIES Legacy does not sell the Products for use in high risk activities The Product is not designed or intended for use in hazardous environments requiring fail safe performance including the operation of nuclear facilities aircraft navigation or communication systems air traffic control weapons systems life support or for use in any circumstance in which the failure of the Product could lead directly to death personal injury or severe physical or property damage or that would affect operation or safety of life support device collectively High Risk Activities Legacy expressly disclaims any express or implied warranty of fitness for High Risk Activities Legacy does not authorize use of any of its products use in any High Risk Activities ANY SUCH USE IS IMPROPER AND IS A MISUSE OF LEGACY PRODUCTS The Limited Warranty is governed by the laws of the United States and the State of Wisconsin without reference to conflict of law principles The application of the United Nations Convention of Contracts for the International Sale of Goods is expressly excluded Contact Information Legacy s address is N9246 Hwy 80 South Necedah WI 54646 and its phone number is 608 565 5878 or 800 859 5711 to
16. nected equipment 4 Has operated the Product at all times within the limitations on the Product s VA capacity as stated in this User Manual Lineage LI2200 Uninterruptible Power System Legacy Does Not Cover or Undertake Any Liability in Any Event for Any of the Following 1 Loss of or damage to data records or software or the restoration of data or records or the reinstallation of software 2 Damage from causes other than AC Power Line Transients spikes or Surges on properly installed grounded and code compliant 120 volt power lines in the United States and Canada transients surges or spikes on standard telephone land lines PBX telephone equipment lines or Ethernet lines when properly installed and connected 3 Damage from any circumstance described as excluded above with respect to the product 4 Damages from fire flood wind rain rising water leakage or breakage of plumbing abuse misuse or alteration of either the product or the Connected Equipment Exclusion of Consequential and Other Damages The sole and exclusive remedies of the Initial Customer are those provided by the Limited Warranty Legacy excludes any liability for personal injury under the Limited Warranty Legacy excludes any liability for direct indirect special incidental or consequential damages whether for damage to or loss of property loss of profits business interruption loss of information or data This exclusion applies even though da
17. of of purchase as described below to have the benefits of this Limited Warranty LIMITED WARRANTY Legacy warrants to you the Initial Purchaser that the Product will be free from defects in material and workmanship for three years from the date of original purchase subject to the terms of this Limited Warranty This Limited Warranty gives you specific rights and you may have other rights which vary from State to State or Province to Province Any Implied Warranty of Merchantability or for Fitness for a Particular Purpose if applicable to the Product is limited in duration to the period of ownership by the Initial Customer This provision shall NOT create any Implied Warranty or Merchantability or of Fitness for a Particular Purpose that would not otherwise apply to the Product NOTE Some States and Provinces do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you To be covered you must still be the owner of the Product at the time of the failure that results in the claim made under this Limited Warranty Exclusive Remedies Under Limited Warranty Your exclusive remedy and Legacys sole obligations are as follows for the Product If a the Legacy Product you purchased and still own is defective in material or workmanship under this Limited Warranty or any applicable warranty imposed by law and b all Limited Warranty requirements have been met Legacy will repair or replace the P
18. roduct if it proves to be defective in material or workmanship during the Warranty Period 11 LEGACY Making a Limited Warranty Claim To make a Limited Warranty claim on a Product you must do the following 1 Complete and return the Legacy Warranty Registration Card or provide reasonable proof of purchase for example a sales receipt that establishes you as the Initial Customer the original end user consumer purchaser of the Product and prove that the Product was purchased within three 3 years of the event for which you want to make a claim for warranty service 2 Call Legacy at 608 565 5878 or 800 859 5711 toll free write to Legacy Power Conversion at N9246 Hwy 80 South Suite 7 Necedah WI 54646 or e mail Legacy at service lpc ups com within ten 10 days of the event for which you want to make a claim 3 When you contact Legacy identify the Product the Purchase Date and request Return Materials Authorization RMA information from Legacy 4 Pack and ship the Product to Legacy as instructed in your RMA Show the RMA code on the shipping label or include it with the Product You MUST prepay all shipping costs and you are responsible for packaging and shipment Legacy will inspect and examine the Product within ten 10 days of receipt If the Product is not as warranted Legacy will repair or replace the Product and return it to you at Legacy s expense or if Legacy is unable to or decides not to repair or r
19. s not providing the UPS off Wait 10 seconds battery power and turn the UPS on This should reset the unit The serial cable is not the cable that was provided with the unit You must use the cable included with the unit for the software iE LEGACY TECHNICAL SPECIFICATIONS Modi con Capacity VA 2200VA Capacity Watts 1500W nput Voltage Range 85 150Vac Frequency Range 47 63Hz Output On Battery Output Voltage Pure Sine Wave at 120Vac 5 On Battery Output Frequency 60Hz 1 Transfer Time Typical On Battery Internal Current Limiting Lightning Surge Protection Internet Ready DSL Phone RJ11 RJ45 One In One Out FAX Modem Protection Total of UPS Receptacles 0 00 6 O Maximum Dimensions cm Weight Kg Sealed Maintenance Free Lead 12Vdc 9AHx4 Acid Battery Typical Recharge Time Indicators Power On Using Battery AVR Wiring Fault Load Level Battery Level Audible Alarms On Battery Low Battery Overload Operating Temperature Operating Relative Humidity 0 to 95 NON CONDENSING SeeUPS2020 Software 10 Lineage LI2200 Uninterruptible Power System LIMITED WARRANTY In purchasing the LI2200 in the United States or Canada the original end user receives a Limited Warranty from Legacy Power Conversion Inc for ease of reading referred to as Legacy The Limited Warranty is intended to be the original end user s exclusive rights and remedies Limited Warranty The original
20. t the USB adapter with the Serial Cable then connect the USB to your computer With the UPS unit off and unplugged connect your computer monitor and any externally powered data storage device Zip drive Toin e s 7 z O ere _ on Jazz drive Tape drive etc into the battery power supplied outlets DO NOT 4 plug a laser printer copier space heater vacuum paper shredder or other large sn 1 J electrical device into the UPS The power demands of these devices will i A p overload and possibly damage the unit f N g To protect a fax telephone modem line or network cable connect a telephone cable or network cable from the wall jack outlet to the IN jack of the UPS Then AH E connect a telephone cable or network cable from the OUT jack on the UPS to the i ult modem computer telephone fax machine or network device Plug the UPS into a 2 pole 3 wire grounding receptacle wall outlet Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not a service equipment with large electrical demands e g refrigerator copier etc oe Avoid using extension cords If used the extension cord must be rated for 15 Us d Amps Depress the power switch to turn the unit on The power on indicator light will illuminate If an overload is detected an audible alarm will sound an