Home

Crest User Manual - Models 1500

image

Contents

1. A This appliance does not have a pilot It is e Immediately call your gas supplier from a equipped with an ignition device which neighbor s phone Follow the gas supplier s automatically lights the burner Do not try instructions to light the burner by hand If you cannot reach your gas supplier call BEFORE OPERATING smell all around the fire department the appliance area for gas Be sure to C U ly your hand to turn the gas control knob smell next to the floor because some gas ae ee 24 g Never use tools If the handle will not turn by is heavier than air and will settle on the hand don t try to repair it call a qualified service floor technician Force or attempted repair may WHAT TO DO IF YOU SMELL GAS result in a fire or explosion Do not try to light any appliance Do not use this appliance if any part has been under water Immediately call a qualified Do not touch any electric switch do service technician to inspect the appliance and not use any phone in your building to replace any part of the control system and any gas control which has been under water OPERATING INSTRUCTIONS 1 STOP Read the safety information 8 Turn gas shutoff valve clockwise to ON above on this label Handle will be parallel to pipe 2 Set the thermostat to lowest setting 9 Install front door 3 Turn off all electric power to the 10 Turn on all electric power to appliance appliance 11 Set thermostat to desired
2. A CAUTION CAUTION indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in property damage NOTICE NOTICE indicates special instructions on installation operation or maintenance that are important but not related to personal injury or property damage Please read before proceeding A WARNING DO NOT install units in rooms or NOTICE NOTICE The Crest Installation and Operation Manual along with the Crest Service Manual are for use only by a qualified heating installer service technician Refer only to this User s Information Manual for your reference Improper installation adjustment alteration service or maintenance can cause property damage personal injury exposure to hazardous materials or loss of life Installation and service must be performed by a qualified installer service agency or the gas supplier who must read and follow the supplied instruction before installing servicing or removing this boiler This boiler contains materials that have been identified as carcinogenic or possibly carcinogenic to humans When calling or writing about the boiler Please have the boiler model and serial number from the boiler rating plate Consider piping and installation when determining boiler location Any claims for damag
3. User s Information Manual Read the list of potential materials listed in Table 1A on page 4 of this manual If any of these products are in the room from which the boiler takes its combustion air they must be removed immediately or the boiler combustion air and vent termination must be relocated to another area Check pressure temperature gauge 1 Make sure the pressure reading on the boiler pressure temperature gauge does not exceed 24 psi 165 5 kPa Higher pressure may indicate a problem with the expansion tank 2 Contact a qualified service technician if problem persists Check vent piping 1 Visually inspect the flue gas vent piping for any signs of blockage leakage or deterioration of the piping Notify your qualified service technician at once if you find any problems Fail i h noted A WARNING allure to WS PECL the veni system as above and have it repaired by a qualified service technician can result in vent system failure causing severe personal injury or death Check air piping 1 Visually inspect the air inlet elbow to be sure it is unobstructed Inspect the entire length of air piping to ensure piping is intact and all joints are properly sealed 2 Call your qualified service technician if you notice any problems Check relief valve 1 Inspect the boiler relief valve and the relief valve discharge pipe for signs of weeping or leakage 2 If the relief valve often weeps the expansion tank may n
4. USER Rev C 1 14
5. boiler piping gas and water 1 Remove the boiler front access door and perform a gas leak inspection per steps 1 through 7 of the Operating Instructions on page 9 If gas odor or leak is detected immediately shut down the boiler following the procedure on page 9 Call a qualified service technician 2 Visually inspect for leaks around water piping Also inspect the circulators relief valve and fittings Immediately call a qualified service technician to repair any leaks A WARNING Have leaks fixed at once by a qualified service technician Failure to comply could result in severe personal injury death or substantial property damage 3 Replace the front access door Operate relief valve 1 Before proceeding verify that the relief valve outlet has been piped to a safe place of discharge avoiding any possibility of scalding from hot water To avoid water damage or scalding due to valve operation a metal discharge line must be connected to the relief valve outlet and run to a safe place of disposal This discharge line must be installed by a qualified heating installer or service technician in accordance with the instructions in the Crest Installation and Operation Manual The discharge line must be terminated so as to eliminate possibility of severe burns or property damage should the valve discharge TRAE M imr User s Information Manual 2 Read the boiler pressure temperature gauge to make sure the system is
6. is located in a laundry room or pool facility for example these areas will always contain hazardous contaminants Pooland laundry products and common household and hobby products often contain fluorine or chlorine compounds When these chemicals pass through the boiler they can form strong acids The acid can eat through the boiler wall causing serious damage and presenting a possible threat of flue gas spillage or boiler water leakage into the building Please read the information listed in Table 1A If contaminating chemicals will be present near the location of the boiler combustion air inlet have your installer pipe the boiler combustion air and vent to another location per the Crest Installation and Operation Manual A WARNING To prevent the potential of severe personal injury or death check for areas and products listed in Table 1A before installing the boiler or air inlet piping If contaminants are found you MUST e Remove products permanently ne e Relocate air inlet and vent terminations to other areas Table 1A Corrosive Contaminants and Sources Products to avoid Spray cans containing chloro fluorocarbons Permanent wave solutions Chlorinated waxes cleaners Chlorine based swimming pool chemicals Calcium chloride used for thawing Sodium chloride used for water softening Refrigerant leaks Paint or varnish removers Hydrochloric acid muriatic acid Cements and glues Antistatic fabric softeners u
7. 5 4 mm fitting on the condensate trap with the factory supplied silicone hose Secure the hose to the condensate trap and the boiler using the factory supplied hose clamps Connect the 3 8 inch 9 8 mm fitting to the 3 8 inch 9 8 mm fitting on the condensate trap shipped loose with the factory supplied silicone hose Secure the hose to the condensate trap and the boiler using the factory supplied hose clamps The condensate trap must be installed at the same level or below the boiler base The condensate trap is sized for a 1 PVC outlet connection pipe Plug the wiring connection from the condensate trap into the connector located on the back of the unit Slope condensate tubing down and away from the boiler into a drain or condensate neutralizing filter Condensate from the Crest will be slightly acidic typically with a pH from 3 to 5 Install a neutralizing filter if required by local codes A neutralizer kit FIG 2 2 is available from the factory KIT40045 The neutralizer kit must be placed on a surface that is a minimum of 3 inches lower than the condensate trap Do not expose condensate line to freezing temperatures NOTICE Use materials approved by the authority having jurisdiction In the absence of other authority PVC and CPVC pipe must comply with ASTM D1785 or D2845 Cement and primer must comply with ASME D2564 or F493 For Canada use CSA or ULC certified PVC or CPVC pipe fittings and cement NOTI
8. CE To allow for proper drainage on large horizontal runs a second line vent may be required and tubing size may need to increase to 1 inch The condensate line must remain unobstructed allowing free flow of condensate If condensate is allowed to freeze in the line or if the line is obstructed in any other manner condensate can exit from the boiler tee resulting in potential water damage to property Call your qualified service technician to inspect the boiler and system 10 A condensate removal pump is required if boiler is below the drain When installing a condensate pump select one approved for use with condensing boilers and furnaces The pump should have an overflow switch to prevent property damage from condensate spillage The switch should be wired to the auxiliary device proving switch terminals on the low voltage connection board Figure 2 2 Condensate Disposal FLOOR DRAIN OR DRAIN PAN CONDENSATE TRAP NEUTRALIZER KIT SAME LEVEL OR BELOW OPTIONAL BOILER BASE 3 MINIMUM BELOW CONDENSATE TRAP 2 Maintenance schedule Test low water cutoff if installed 1 Ifthe system is equipped with a low water cutoff test the low water cutoff periodically during the heating season following the low water cutoff manufacturer s instructions Reset button low water cutoff 1 Testing the low water cutoff shuts the unit off Press the RESET button on the low water cutoff to turn the unit back on Check
9. FB USER Rev C CREST CONDENSING BOILER User s Information Manual Models 15 50 Coal WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and CERTIFI ED liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS e Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building e Immediately call your gas supplier from a near by phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier High Efficiency Water Heaters Boilers and Pool Heaters Save this manual for future reference Contents HAZARD DEFINITIONS oreren 2 3 OPERATING INSTRUCTIONS wsivietuteohcadpsnamanvapanetsines 9 PLEASE READ BEFORE PROCEEDING ccccc0000 3 4 SMART TOUCH CONTROL MODULE 1 PREVENT COMBUSTION AIR CONTAMINATION 4 Crest Control MOdUule ccccccccscsssseseeceeeeeeeeeeeeeeeeeees 10 2 MAINTENANCE SCHEDULE c00ccccceeeeeeeeeeeees 5 Home SCP SCM ova vedninnivevinecesondaaewnananiedabdeeunasnerauctanenteseus 10 Maintenance Procedures cccccccecessseeceeeeseeseseeeeeeeaeees 6 Ma
10. by pressing the appropriate button Figure 4 1 Home Screen STATUS Main Burner On Set Point 110 F System Supply 12 45 Nevis ol When the ON OFF switch is turned to the ON position the first screen visible on the LCD display will be the Home Screen This screen displays the current status of the Crest boiler The following items can be viewed or interacted with on the Status Screen On Off button Pressing this button allows the boiler to be placed in either Manual Shutdown Mode or Standby Mode Status This line shows the current operating status of the Crest boiler and the current set point Outlet Water Temperature This is the boiler outlet temperature Inlet Water Temperature This is the boiler inlet temperature System Supply Temperature This is the water temperature as measured by the system supply sensor located in the downstream piping if connected System Return Temperature This is the water temperature measured by the system return sensor located in the upstream piping if connected Outside Air Temperature This is the outdoor air temperature if connected E 0 AEs j Inlet WaterTemperature an eremm System Return Temperature 80 F DHW Temperature 140 Fy DHW Temperature This is the temperature as measured by the tank sensor in the hot water storage tank if connected Flue Temperature Temperature measured by the flue sensor Time The time is disp
11. e information additional screens which are used to set temperatures regarding the nine 9 accessible screens operating conditions and monitor boiler operation These screens are as follows e Home Navigates back to the Home Screen e Setup Allows access to 12 other screens for the adjustment of the control parameters e Cascade Shows the status of multiple boilers connected together in a cascade arrangement Leader only e Modulation Shows the status of the two 2 gas train systems used in the boiler e BMS Shows the information from a Building Integration System e Pumps Allows the installer to configure the boiler system and DHW pumps e History Shows the operating and fault history of the control module e Graphs Allows the selection of items to be graphed on a chart e Service Allows the installer to control the fan speed of the individual combustion systems for the purposes of combustion analysis Service Mode will override all other heat demands however all limits will remain active E g Lochinvar V High Efficiency Water Heaters Boilers and Pool Heaters 300 Maddox Simpson Parkway Lebanon TN 37090 615 889 8900 Fax 615 547 1000 www Lochinvar com Revision Notes Revision A ECO C07970 initial release Revision B ECO C11613 reflects the addition of models 4 0 and 5 0 Revision C ECO C14386 reflects the addition of the corrosive contaminant warning on page 3 R06313 FB
12. e or shortage in shipment must be filed immediately against the transportation company by the consignee Factory warranty shipped with unit does not apply to units improperly installed or improperly operated ARNING Failure to adhere to the guidelines on this page can result in severe personal injury death or substantial property damage CPSP AP Ae EC e n User s Information Manual environments that contain corrosive contaminants see Table 1A on page 4 Failure to comply could result in severe personal injury death or substantial property damage Boiler service and maintenance e To avoid electric shock disconnect electrical supply before performing maintenance e To avoid severe burns allow boiler to cool before performing maintenance Boiler operation e Do not block flow of combustion or ventilation air to the boiler e Should overheating occur or gas supply fail to shut off do not turn off or disconnect electrical supply to the circulator Instead shut off the gas supply at a location external to the appliance e Do not use this boiler if any part has been under water The possible damage to a flooded appliance can be extensive and present numerous safety hazards Any appliance that has been under water must be replaced Boiler water Thoroughly flush the system without boiler connected to remove sediment The high efficiency heat exchanger can be damaged by build up or c
13. in Menu Screen c ccseecccececesseeeceeceeeeeeeeeesseeeees 11 Boiler Must Be Serviced and Maintained 6 Revision Notes ccccsscecsseceseesseeseseeseeeeesaaeees Back Cover Check Boiler Ar a ccccccccccesseeeeeeeceeeseceeeeeeeeseeees 6 Check Pressure Temperature GaugQe cccssseeeeeeees 6 Check Vent PIPING escent cecaaeacnieasteenseteatexctocaderedenedoncaats 6 Check Air Piping ccecsscactotectacevtestosestwotedececdatahdexeadedovsncned 6 Check Relief Valve seeissseeirneererneerrrieerrrreerrrreerrrreenn 6 Check Condensate Drain System cccccesseeeeeeeees 6 Test Low Water Cutoff if installed ceeeeeeeees 8 Reset Button low water Cutoff ccccecesseeeeeeeeeees 8 Check Boiler Piping gas and water ssseseeeeeees 8 Operate Relief Valve cccseseeeecceceeeeeeeseeesseeeeeeeeees 8 Shut Boiler DOWN nsisacieininiiittassdiacdsnbetscawianliimmtendennstacmwis 8 Hazard definitions The following defined terms are used throughout this manual to bring attention to the presence of hazards of various risk levels or to important information concerning the life of the product A DANGER DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury A WARNING WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury
14. in equipment failure causing possible severe personal injury death or substantial property damage The following information provides detailed instructions for completing the maintenance items listed in the maintenance schedule on page 5 In addition to this maintenance the boiler must be serviced and started up at the beginning of each heating season by a qualified service technician Check boiler area A WARNING To prevent potential of severe personal injury death or substantial property damage eliminate all materials discussed below from the boiler vicinity and the vicinity of the boiler combustion air inlet If contaminants are found Remove products immediately from the area If they have been there for an extended period call a qualified service technician to inspect the boiler for possible damage from acid corrosion If products cannot be removed immediately call a qualified service technician to re pipe vent and air piping and locate vent termination air intake away from contaminated areas 1 Combustible flammable materials Do not store combustible materials gasoline or any other flammable vapors or liquids near the boiler Remove immediately if found 2 Air contaminants Products containing chlorine or fluorine if allowed to contaminate the boiler intake air will cause acidic condensate in the boiler This will cause significant damage to the boiler if allowed to continue 6 TRAE Pl 4s PAE
15. layed in the lower left hand corner of the display Reference the Crest Service Manual for Night Setback parameters and more information regarding adjusting the date and time Boiler Status button Pressing this button brings up the Boiler Status Screen This screen shows the status of the various safeties inputs and outputs to the control module Reference the Boiler Status Screen section in the Crest Service Manual for more information regarding this screen Main Menu button Pressing this button brings up the Main Menu Screen From this screen navigation to nine 9 other screens is possible Reference the Main Menu Screen section on page 52 of this manual for more information regarding this screen Modulation button Pressing this button brings up the Modulation Screen This screen shows overall boiler modulation individual fan speeds and flame currents Modulation Percentage Displays the current boiler firing rate CREST User s Information Manual COME NAINE wee 4 SMART TOUCH control module continued Use the Main Menu Screen FIG 4 2 to access the screens necessary to set temperatures operating conditions and monitor boiler operation The Crest is equipped with a SMART TOUCH control system All menu options are accessed by touching the screen with your finger or a stylus from a PDA Figure 4 2 Main Menu Screen The Main Menu Screen allows navigation to nine 9 Reference the Crest Service Manual for mor
16. orrosion due to sediment e Do not use petroleum based cleaning or sealing compounds in the boiler system Gaskets and seals in the system may be damaged This can result in substantial property damage e Do not use homemade cures or boiler patent medicines Serious damage to the boiler personnel and or property may result e Continual fresh make up water will reduce boiler life Mineral buildup in the heat exchanger reduces heat transfer overheats the stainless steel heat exchanger and causes failure Addition of oxygen carried in by makeup water can cause internal corrosion Leaks in boiler or piping must be repaired at once to prevent makeup water Freeze protection fluids e NEVER use automotive antifreeze Use only inhibited propylene glycol solutions which are specifically formulated for hydronic systems Ethylene glycol is toxic and can attack gaskets and seals used in hydronic systems 3 Oe Ae Paes FP R User s Information Manual 1 Prevent combustion air contamination If the boiler combustion air inlet is located in any area likely to cause contamination or if products which would contaminate the air cannot be removed you must have the combustion air and vent re piped and terminated to another location Contaminated combustion air will damage the boiler resulting in possible severe personal injury death or substantial property damage A WARNING If the boiler combustion air inlet
17. ot be working properly Immediately contact your qualified service technician to inspect the boiler and system Check condensate drain system 1 Inspect the condensate drain line vent line condensate PVC fittings and condensate trap Flush condensate trap with water 1 Remove the four 4 screws securing the top cover to the condensate trap and remove the cover FIG 2 1 2 Locate the plastic ball inside the float tube Verify there is nothing under the ball causing it to not seat properly 3 Fill with fresh water until the water begins to pour out of the drain 4 Replace the top cover and the screws removed in Step 1 CREST User s Information Manual UGARAN te a e R 2 Maintenance schedule continued The condensate trap FIG 2 1 must A WARNING be filled with water during all times of boiler operation to avoid flue gas emission from the condensate drain line Failure to fill the trap could result in severe personal injury or death Figure 2 1 Condensate Trap TO FLOOR DRAIN FROM CONDENSATE VENT ON BOILER FROM CONDENSATE DRAIN ON BOILER OR NEUTRALIZER KIT 1 PVC CPVC CONNECTION Condensate disposal l The Crest is a high efficiency appliance that produces condensate The rear of the boiler has a 1 inch 25 4 mm stainless steel drain fitting and a 3 8 inch 9 8 mm stainless steel vent line for connection to the condensate trap Connect the 1 inch 25 4 mm fitting to the 1 inch 2
18. pressurized Lift the relief valve top lever slightly allowing water to relieve through the valve and discharge piping 3 If water flows freely release the lever and allow the valve to seat Watch the end of the relief valve discharge pipe to ensure that the valve does not weep after the line has had time to drain If the valve weeps lift the seat again to attempt to clean the valve seat If the valve continues to weep afterwards contact your qualified service technician to inspect the valve and system 4 If water does not flow from the valve when you lift the lever completely the valve or discharge line may be blocked Immediately shut down the boiler following the operating instructions on page 9 of this manual Call your qualified service technician to inspect the boiler and system Shut boiler down unless boiler is used for Domestic Water 1 Follow To Turn Off Gas to Appliance on page 9 of this manual 2 Do not drain the system unless exposure to freezing temperatures will occur 3 Do not drain the system if it is filled with an antifreeze solution 4 DO NOT shut down boilers used for domestic water heating they must operate year round CREST User s Information Manual TRAP Bl te PAPE 3 Operating instructions FOR YOUR SAFETY READ BEFORE OPERATING WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life
19. rformance verification per Section 9 am H lt H v al lt _ lt lt lt e Flame inspection stable uniform e Test low water cutoff e Check both flame signals at least 10 microamps at high fire Every e Reset button low water cutoff 6 months e Clean the heat exchanger e Check boiler piping gas and e est low water cutoff reference the water for leaks Crest Service Manual e Operate relief valve If combustion or performance indicate need e Clean heat exchanger End e Remove and clean burner using of season compressed air only months e Shut boiler down unless boiler used for domestic hot water e Clean the blower wheel Follow the maintenance procedures given throughout this manual Failure to perform the service and A WARNING Oar cae l maintenance or follow the directions in this manual could result in damage to the boiler or system resulting in severe personal injury death or substantial property damage 5 2 Maintenance schedule Maintenance procedures Boiler must be serviced and maintained The boiler must be inspected and started annually at the beginning of the heating season by a qualified service technician In addition the maintenance and care of the boiler designated on page 5 of this manual and explained on pages 6 through 8 must be performed to assure maximum boiler efficiency and reliability Failure to service and maintain the boiler and system could result
20. sed in clothes dryers Chlorine type bleaches detergents and cleaning solvents found in household laundry rooms Adhesives used to fasten building products and other similar products Areas likely to have contaminants Dry cleaning laundry areas and establishments Swimming pools Metal fabrication plants Beauty shops Refrigeration repair shops Photo processing plants Auto body shops Plastic manufacturing plants Furniture refinishing areas and establishments New building construction Remodeling areas Garages with workshops CREST User s Information Manual 2 Maintenance schedule Service technician Owner maintenance see the Crest Service Manual see pages 6 8 for detailed instructions General e Address reported problems if any e Check boiler area e Inspect interior clean and vacuum if necessary e Check pressure temperature gauge e Clean condensate trap and fill with fresh water e Check for leaks water gas flue condensate e Verify flue and air lines in good condition e Check t pipi and sealed tight eck vent piping eCheck system water pressure system e Check air piping iping expansion tank Pore re Monthly e Check air and vent termination e Check control settings screens e Check ignition and flame sense lt Check relief valve electrodes sand off any deposits clean and reposition e Check condensate drain system e Check wiring and connections e Perform start up checkout and pe
21. setting 4 This appliance is equipped with an 12 If the appliance will not operate follow the ignition device which automatically lights instructions To Turn Off Gas To Appliance and ee Do not try to light the burner call your service technician or gas supplier ees Gas Valve Gas Valve 5 Remove front door OPEN CLOSED 6 Turn gas shutoff valve counterclockwise ay to OFF Handle will be perpendicular to to CLOSE pipe Do not force 7 Wait five 5 minutes to clear out any gas If you then smell gas STOP Follow B in the safety information above this label If you don t smell gas go to next step AN AS 7 TO TURN OFF GAS TO APPLIANCE Set the thermostat to lowest setting 4 Turngas shut off valve counterclockwise to Turn off all electric power to the appliance OFF Handle will be perpendicular to pipe if service is to be performed Do not force Remove front door 5 Install front door LBL20053 REV B User s Information Manual COMPDEN NE Oe 4 SMART TOUCH control module EMINI TOUCH Crest control module The Home Screen displays status modulation rate outlet water temperature inlet water temperature flue temperature system supply temperature system return temperature outdoor air temperature and domestic hot water tank temperature The boiler can be started and stopped by pressing the ON OFF button The Boiler Status Screen and Main Menu Screen can be accessed