Home

BDF-XX-CRX

image

Contents

1. FEMA ELECTRONICA Page 3 User s Manual BDF xx CRH CRM CRS and CR7 General specifications DISPLAY 4 or 6 digits in red color 7 segment Led reading from 9999 to 9999 in 4 digits reading from 999999 to 999999 in 6 digits decimal point selectable digit 57 mm 2 3 in BDF 24 and BDF 26 digit 100 mm 4 0 in BDF 44 and BDF 46 antirreflexive front filter IP65 front protection ENVIRONMENTAL DATA Working Temp 0 50 C 32 122 F Storage Temp 20 85 C 4 185 F Rel Humidity 0 to 85 non condensated HOUSING extruded aluminium anodized in black color for panel mount optional wall mount POWER SUPPLY standard 230 Vac 50 60 Hz optional 115 Vac 50 60 Hz CONSUMPTION 6 VA in series BDF 24 and BDF 26 12 VA in series BDF 44 and BDF 46 Program codes 4 digit units MODEL CRH Range 1999 Hours 41 1 Reset to default values Switch to counter mode 45 4 Factor x0 001 44 2 Flange x2 3 Factor x 0 0028 a 60Hz 0 0023 2 Maximum 1999 56 5 Load 0000 when reaching 1999 MODEL CRM Range 9999 Min 41 1 Reset to default values Switch to counter mode 45 4 Factor x 0 001 3 Factor x 0 3333 a 60Hz 0 2778 2 Maximum 9999 56 5 Load 0000 when reaching 9999 MODEL CRS Range 9999 Sec 41 1 Reset to default values Switch to counter mode 45 3 Factor x 0 01 3 Factor x 2 0000 a 60Hz 1 6666 2 Maximum 9999 56 5 Load 0000 when reaching 9999 MO
2. 41 1 Button acts as a validation of the code and value entered If this button is not pressed the unit will not validate the new value EXAMPLE Introducing code 41 1 Press 4 Number 4 appears on display to the left Press 1 Number 1 appears on display to the left The current value for code 41 appears to the right it can be 1 or 2 Press 2 Number 2 appears on display to the right replacing the previous value Press Validates the code and the value entered in this case 41 1 Note After 6 seconds without introducing data the instru ment will cancel the programming code without validation Note Codes 1 2 and 3 are special codes composed by only 1 digit The value is a 6 digit numerical value and will load on display as soon as the code is pressed The way to modify this value is to modify each digit value independently by pressing 1 to 6 and then to validate the whole KBD programming keyboard Figure 1 Function of the programming terminal pins O Pin 1 common ss Pin 9 re button Jedi 1 Pin2 a button 6 101 O2 Pin 10 n button 5 11 O 3 Pin 3 n button 4 125 f Pin n button 3 13 O o 6 Pin4 e button 2 O olz E Pin 12 a button 1 O Sla Pin5 ea button ENTER O Pins 6 13 and 14 shortcircuited Pin 7 8 and 15 leave open FEMA
3. Page 4 Programming codes The BDF Time Counter instruments are configured by programming codes that activate internal scale factors decimal points and other elements which scale the signal counted on display The programming of these codes is done through the 15 pin SUB D connector at the rear side of the instrument A KBD Programming Keyboard is needed or the connections shown in Figure 1 need to be set up Buttons 1 to 6 introduce the numerical characters 1 2 3 4 5 and 6 on display button executes ENTER on the displayed code Button adds negative sign in some codes Note When KBD or contacts indicated in Figure 1 are con nected to the BDF the point placed under the negative sign will light This led must be on during the reprogramming of the unit if the led is not lightning but the led on top of the negative sign lights then press to switch leds Note When KBD or contacts indicated in Figure 1 are connected to the BDF Ratemeter with 4 digits the 2 small 7 segment displays on top left part will light These digits are needed to program some codes which are 6 digit codes User s Manual BDF xx CRH CRM CRS and CR7 Programming example The programming codes are made of 2 digits identifying the code and a third digit identifying the value assigned to the code Code 41 with value 1 is represented as
4. until it presses the panel 4 and is firmly fixed Note The front of the instrument is sealed IP65 To have the same level of protection between the panel and the instru ment place a rubber profile squared or round as indicated D 1 Instrument BDF 2 Screw N N 3 Fixation tool 4 Panel 5 Rubber profile FEMA ELECTR NICA Page 6 User s Manual BDF xx CRH CRM CRS and CR7 Warranty All instruments are warranted against all manufacturing defects for a period of 24 MONTHS from the shipment date This warranty does not apply in case of misuse accident or manipulation by non authorized personnel In case of mal function get in contact with your local provider to arrange for repair Within the warranty period and after examination by the manufacturer the unit will be repaired or substituted when found to be defective The scope of this warranty is limited to the repair cost of the instrument not being the manufacturer eligible for responsibility on additional damages or costs CE Declaration of conformity Manufacturer FEMA ELECTRONICA S A Altimira 14 Pol Ind Santiga E08210 Barbera del Valles BARCELONA SPAIN www fema es info fema es Series Models BDF 24 y BDF 44 CRH CRM CRS and CR7 The manufacturer declares that the instruments indicated comply with the directives and rules indicated below Directive of electromagnetic compatibility 2004 108 CEE Directive of lo
5. ELECTR NICA Page 5 Mechanical dimensions User s Manual BDF xx CRH CRM CRS and CR7 Panel cut out and weights Size 24 A B C 4 digits 5 mm 264mm 120mm 112mm 2 10 40 4 75 4 41 Size 44 A B C 4 digits 100mm 480mm 180mm 112mm 4 18 90 7 09 4 41 Size 26 A B C 6 digits 5 mm 384mm 120mm 112mm 2 15 12 4 75 4 41 Size 46 A B C 6 digits 100mm 668mm 180mm 112mm 4 27 10 7 09 4 41 Note add 27mm to the C dimension for the power supply plug C ee I Rear cover TL Antirreflexive filter ee i 7 Size 24 D E weight 4 digits 5 mm 256mm 112mm 2 3 Kg 2 10 07 4 40 5 Ibs Size 44 D E weight 4 digits 100mm 472mm 172mm 5 0 Kg 4 18 58 6 77 11 Ibs Size 26 D E weight 6 digits 5 mm 376mm 112mm 2 7 Kg 2 14 80 4 40 6 Ibs Size 46 D E weight 6 digits 100mm 680mm 172mm 5 7 Kg 4 36 77 6 77 12 5 Ibs PANEL CUT OUT A E lt D p y Panel width Max 14 mm 0 55 Min 2 5 mm 0 10 Panel installation Introduce instrument 1 into the panel cut out and place the fixation piece 3 on each side Place screw 2 through fixa tion piece 3
6. CTRONIC INSTRUMENTATION FOR INDUSTRY FEMA ELECTRONICA S A Altimira 14 Pol Ind Santiga E08210 Barber del Vall s RYN 4 inl RO NV WIN EAI Tel 34 93 729 6004 www fema es Fax 34 93 729 6003 info fema es
7. DEL CR7 Range 99 99 Sec 41 1 Reset to default values Switch to counter mode 3 Factor x 2 0000 a 60Hz 1 6666 2 Maximum 99 99 56 5 Load 00 00 when reaching 99 99 46 3 Decimal point XX XX Internal jumpers The internal jumpers at the control panel must be configured as indicated below Jumpers A B C D F Closed Jumpers E Open Jumpers H G Closed Jumpers J K Open Control board H i E NN ma a ae F eu III IST KJHGFEDCBA EEE EE eee ELT Program codes 6 digit units MODEL CRH Range 1999 99 Hours 41 1 Reset to default values Switch to counter mode 45 4 Factor x0 001 44 2 Flange x2 3 Factor x 0 002778 a 60Hz 0 002315 2 Maximum 1999 99 56 5 Load 0000 00 when reaching 1999 99 46 3 Decimal point XXXX XX MODEL CRM Range 150000 Min 41 1 Reset to default values j Switch to counter mode 45 4H Factor x 0 001 3 Factor x 0 333333 a 60Hz 0 277778 2 Maximum 150000 56 5 Load 0000 00 when reaching 150000 MODEL CRS Range 999999 Sec 41 1 Reset to default values Switch to counter mode 45 3 Factor x 0 01 3 Factor x 2 000000 a 60Hz 1 666666 2 Maximum 999999 56 5 Load 0000 00 when reaching 999999 MODEL CR7 Range 9999 99 Sec 41 1 Reset to default values i Switch to counter mode 3 Factor x 2 000000 a 60Hz 1 666666 2 Maximum 9999 99 56 5 Load 0000 00 when reaching 9999 99 46 3 Decimal point XXXX XX FEMA ELECTR NICA
8. Large Displays for time counters BDF xx CRH counter of hours BDF xx CRM Counter of minutes BDF xx CRS Counter of seconds BDF xx CR Counter of cents of second IDEAL SOLUTION for counting time in decimal format seconds minutes hours and indicating the value at long distances All units with reset and control for start stop Very strong housing and electrically protected units designed for all type of industrial applications User s Manual BDF xx CRH CRM CRS and CR7 ModelsCRH CRM CRSandCR7 Large displays for time counting The BDF series of large displays for time counting appli cations is made of models CRH CRM CRS and CR7 All units are available in 4 and 6 digits format with 5 mm or 100mm digit height All units have control for START STOP function with mechanical contact and RESET function The mechanical of the BDF instruments is a very strong and sturdy aluminium housing anodized in black color for panel mount and for wall mount as an option The front lens is antir reflexive and is firmly inserted on the aluminium profile with a rubber gasket around providing IP65 protection on the front The signal wires are connected to plug in screw clamps for higher security of the connections accessible at the rear side of the instrument The power is connected to a 3 terminal plug 2 power connections and 1 earth containing an integrated protection fuse and an additional f
9. ew A BABB Decimal point selectable 588888 Negative sign Negative sign Decimal point selectable The BDF Time Counter units are available in 4 and 6 digits format All digits are 7 segment LED type with decimal point negative sign and red color Leds B and D are lighted when the unit is being repro grammed through the Programming Terminal on the rear cover Digits A are only available in units with 4 digits These small digits will light only when the unit is being reprogrammed through the Programming Terminal on the rear cover Connections terminal All BDF Counter units have RESET function by mechani cal contact on the rear side of the instrument Connection is done between terminals E Reset and A Common Connections for START and STOP control are done between terminals B and D The status of this switch will determine if the units counts or not counts RESET O START STOP ruv oou m Power supply connections The power connector allows one terminal for earth and two power terminals Internal fuse is integrated on the connector and an additional fuse is available as a spare part The value of the fuses depends on the power supply and is according to rule IEC127 2 230 Vac 200 mA fuse time lag 115 Vac 400 mA fuse time lag Powered 230 Vac 115 Vac optional
10. g the wiring of the sen sors probes transducers etc The wires can act as antennas and introduce electrical noise from the environment into the signal wires specially if the wires are close to noise sources or electromagnetic sources There are several rules generally known which should be taken into consideration for the wiring a DO NOT install impulse control or signal wires together in the same conduits as the wires connected to power lines connected to CC or AC engines electromagnets b When using shielded wires connect the shield to the common of the instrument and leave not connected the probe side c The wires of impulse control and signal should be placed in places far away from switches transformers control relays etc IN CASE OF FIRE 1 Disconnect the unit from the power supply 2 Give the alarm according to the local rules 3 Switch off all the air conditioning devices 4 Attack the fire with carbonic snow do not use water in any case WARNING In closed areas do not use systems with vaporized liquids FEMA ELECTRONICA Page 7 other products Panel Meters Panel Meters Panel Meters Standard 96x48mm Small 72x36 mm Miniature 48x24 mm gt a Large Displays Signal Converters Panel Meters 60 amp 100 mm digit amp Isolators Standard 96x48mm www fema es ELE
11. ubstitution maintenance repair etc the instrument must be unplugged from the power supply The instrument must be installed in places with good ventilation to avoid excessive heating and far from sources of electrical noise or magnetic field generators such as power relays electrical motors speed controls etc The instrument can not be installed in open places Do not use until the installation is finished The instrument is designed to be mounted on a metallic panel with the adequate protections DO NOT clean the front lens with abrasive products such as solvents alcohol etc use a clean and water humid rag Do not expose the instrument to excessive moisture DO NOT operate the unit in the presence of flammable gases or fumes EXCITATION VOLTAGE Vexc Instruments BDF xx 32 and BDF xx 36 supply an excitation voltage of 10 to 24 Vdc 50mA to power transducers available between terminals A and C Do NOT connect these terminals to an external power supply permanent damages may result on both instruments POWER SUPPLY Connect the Power Supply to the terminals indicated in this manual Verify that the voltage and frequency of the power supply is according to the voltage and frequency values indicated in the label attached to the unit DO NOT connect the instrument to power lines which are overloaded or power lines with loads working in ON OFF cycles or with inductive loads SIGNAL WIRING Information to consider relatin
12. use as spare part Order reference Size Model Power Color Others BDF 24 CRS 0 R 24 CRH 0 230 Vac Red 65 IP65 44 CRM 1 115 Vac Green empty 26 CRS check for 46 CR7 availability the IP65 option uses a completely different type of housing from the indicated in this documentation Check the BDF IP65 housing docu 7 mentation for more information Sizes SIZE BDF 24 Instrument with 4 digits digit 57mm height 2 3 SIZE BDF 44 Instrument with 4 digits digit 100 mm height 4 0 SIZE BDF 26 Instrument with 6 digits 5 mm digit height SIZE BDF 46 Instrument with 6 digits 100mm digit height FEMA ELECTRONICA Page 2 User s Manual BDF xx CRH CRM CRS and CR7 Models MODEL BDF xx CRH Time counter for Hours up to 1999 99 hours with control for START STOP and RESET MODEL BDF xx CRM Time counter for Minutes up to 150000 minutes with control for START STOP and RESET MODEL BDF xx CRS Time counter for Seconds up to 999999 seconds with control for START STOP and RESET MODEL BDF xx CR7 Time counter for Cents of Second up to 1999 99 seconds with control for START STOP and RESET Rear view Programming Terminal Power includes fuse Terminal for input impulses and control Front vi
13. w voltage 73 23 CEE Security rules 61010 1 Emission rules 50081 2 Immunity rules 50082 1 NOTE During an electromagnetic disturbance 10V m it is permitted a worst case error of 1 of the A D range The instrument will recover automatically its functionality when the disturbance stops without need of the operator to reset or restart Barber del Vall s October 2009 Daniel Junc Quality Manager Precautions on installation INSTALLATION PRECAUTIONS The installation and 1 operation of this instrument must be done by qualified operators This instrumentDOES NOT have power switch and will start to operate as soon as the power supply is connected The instrument has an internal protection fuse according to IEC 127 2 and is located inside the power supply connector The values are Fuse 200 mA Time Lag for 230 Vac power Fuse 400 mA Time Lag for 115 Vac power Fuse 350 mA Fast for 24 Vdc power When the instrument is used to control machines or processes where the personnel or the process can be damaged the appropriate security ele ments must be added to the system in order to protect the operator and or the system SAFETY PRESCRIPTIONS This instrument has been designed and veri fied according to the UNE 20553 rules and is delivered in perfect conditions of operation This manual contains the adequate infor mation for the electrical installation Before starting operations for connections readjustment s

Download Pdf Manuals

image

Related Search

BDF XX CRX

Related Contents

Mode d`emploi CD-200  日本側報告(2)(PDF: 125KB)  DIN-A-MITE - Artisan Technology Group  « Première connexion à m@gistère » MODE D`EMPLOI  SewArt user manual  Field Test Procedure for MICROLOGIC® Ground  www.philips.com/welcome 1  ETHOS Plus User Manual - Snap-on  scarica il manuale  om, weedeater, we261, 96028000103, 2012  