Home
Hurricane 1000 User Manual Rev. 1
Contents
1. ZHPRRICANE A User Manual TABLE OF CONTENTS 1 Before You Begi What Is Included Unpacking Instructions Claims Text Conventions Symbols Disclaimer Product at a Glance Safety Notes 2 Introduction Overview Dimensions 3 Setup AC Power Fuse Replacement Mounting Orientation Rigging 4 Operation Remote or Manual Operation Wired Manual Remote Control FC M Wireless Remote FC W 5 Technical Information Fogger Maintenance Storage 6 General Troubleshooting 7 Technical Specifications Returns Contact Us oi Down Non ue t t ww w Page 2 of i4 Huricane 1000 User Manual Rev 1 1 BEFORE YOU BEGIN What Is Included Unpacking Instructions Claims Text Conventions Symbols Disclaimer Hurricane 1000 FC M Wired Remote Control FC W Wireless Remote Warranty Card Quick Reference Guide Carefully unpack the product immediately and check the container to make sure all the parts are in the package and are in good condition If the box or the contents the product and included accessories appear damaged from shipping or show signs of mishandling notify the carrier immediately not Chauvet Failure to report damage to the carrier immediately may invalidate your claim In addition keep the box and contents for inspection For other issues such as missing components or parts damage not related to shipping or concealed damag
2. atter in the heating element The recommended cleaning procedure is as follows Unplug the product from power Empty all fog fluid from the machine Add cleaning solution to the tank Connect the product to power and allow it to warm up Run the unit in a well ventilated area until the tank is almost empty Do not allow the pump to run dry 6 Refil with fogger fluid to continue using the fogger Run the machine briefly to clear any remaining cleaning solution from the pump and heater Do Not operate the machine without fluid at any time Fog Cleaner Quart FCQ was specifically developed by Chauvet to clean your Hurricane 1000 Make sure you use FCQ regularly no longer than 90 days between cleanings to increase the life of your product Before storing the fogger run FCQ through the system as described in the cleaning procedure above however only follow steps 1 through 5 Do not refill the tank with fog fluid if storing the fogger Cleaning the system prior to storage will help prevent any particles from condensing inside the pump or heater while not in use Testrun your Hurricane 1000 on a monthly basis to achieve the best performance Page 10 of 14 Huricane 1000 User Manual Rev 1 6 GENERAL TROUBLESHOOTING Symptom Possible Cause Possible Action Line blockage or air in fluid line No output or short output Make sure there is fluid in the tank Turn fog machine 45 to flatten out the bu
3. bble and allow the fog fluid to flow properly Turn off the product for 5 seconds and then tum it back on Repeat as necessary Note After more than 10 attempts contact Customer Service Incorrect fluid Clean thoroughly with CHAUVET FCQ For full instructions see Fogger Maintenance Refill with CHAUVET water based fog fluid Incorrect fluid Clean thoroughly with CHAUVET FCQ For full instructions see Fogger Maintenance Refill with CHAUVET water based fog fluid No output or spitting fluid Fuse keeps blowing Blocked pipes Contact Customer Service Falling part Contact Customer Service Excessive load on the Make sure that the total load does not exceed 80 of the circuit breaker or fuse nominal current Short circuit along the power lines Check the power lines and power cords No energy on power outlet Check power outlet Change to another outlet Loose or damaged power Product does not power up cord Check the power cord Blown fuse Replace blown fuse with a good one of the same type and rating Internal problem Send product for repair Product stops pumping Loud noise Low No Fluid Refill product with fluid If you still experience problems after trying the solutions presented here contact Chauvet Technical Support See Con Us Hurricane 1000 User Manual Rev T Page 11 of 14 7 TECHNICAL SPECIFICATIONS Dimen
4. ce and fuid replenishment Make sure that the structure or surface onto which you are mounting the product can support the product s weight see the Technical Specifications When mounting the product overhead always use a safely cable Mount the product securely to a rigging point such as an elevated platform or a truss When rigging the product onto a truss you should use a mounting clamp of appropriate weight capacity The bracket has 13 mm holes which are appropriate for this purpose The rubber feet also serve as floor supports and allow for surface mounting When mounting the product on the floor make sure that the product and cables are away from people and vehicles Mounting Clamp feun as ARIF AR camp fom Chauvet ors tt rom Mounting Diagram 57 Bracket Adjustment Knob the machine to prevent pump and heater damage When the fog fluid level While operating the Hurricane 1000 make sure there is adequate fog fluid in becomes low simply add more fog fluid to continue using the Hurricane 1000 Page 8 of 14 Furicane 1000 User Manual Rev 1 4 OPERATION Remote OF the Hunicane 1000 can be operated manually or with the included wired manual Manual remote control FC M or wireless remote FC W The Manual button is located on the Pm rearofthe unit See the product Overview Operation x Wired Manual The FC M wired manual remote control allows the user to start and stop the fog output It operate
5. ct s back panel or refer to the products specifications chart The listed current rating indicates the product s average current draw under normal conditions Always connect the product to a protected circuit circuit breaker or fuse Make sure the product has an appropriate electrical ground to avoid the risk of electrocution or fire To eliminate unnecessary wear and improve its lifespan during periods of non use completely disconnect the product from power via breaker or by unplugging it Never connect the product to a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel serves only as a 0 to 100 switch Fuse 1 Disconnect the product from power Replacement 2 Twist the fuse holder cap counterclockwise to loosen the fuse holder and pull straight out 3 Remove the blown fuse Replace with a fuse of the same type and rating 5 Screw the fuse holder cap back in place and reconnect power Disconnect the product from power before replacing the fuse Always replace a blown fuse with another of the same type and rating Huricane 1000 User Manual Rev T Page 7 of 14 Mounting Before mounting the product read and follow the safety recommendations indicated in the Safety Notes Orientation This product may not be tilted This product should only be mounted used on a level surface Rigging Before deciding on a location always make sure there is easy access to the product for maintenan
6. e file a claim with Chauvet within 7 days of delivery Convention Meaning 1 512 A range of values 50 60 A set of values Settings A menu option Menu gt Settings A sequence of menu options lt Enter gt A button Symbol Meaning Critical installation configuration or operation information Not following these instructions may make the product not work cause damage to the product or cause harm to the operator Important installation or configuration information The product may not function correctly if this information is not used Useful information The information and specifications contained in this User Manual are subject to change without notice Chauvet assumes no responsibilty or liability for any errors or omissions and reserves the right to revise or recreate this manual at any time Download the latest version from www chauvetlighting com Copyright 2015 Chauvet All rights reserved Electronically published by Chauvet in the United States of America Author Date Eder Dae R Isenstadt weis Auen ous Hurricane 1000 User Manual Rev T Page Saf 1 Product at a Use on Dimmer X Auto Programs x Glance Outdoor Use X_ Fixed voltage 120 V or 230 V P Sound Activated X Replaceable Fuse P DMX X UserSeniceable x Master Slave x Duty cyce x Safety Notes These notes include important information about the mounti
7. lux It you are located outside the U S UK Ireland Mexico or Benelux contact your distributor of record and follow their instructions on how to return Chauvet products to them Visit our website www chauvetlighting com for contact details Call the corresponding Chauvet Technical Support office and request a Return Merchandise Authorization RMA number before shipping the product Be prepared to provide the model number serial number and a brief description of the cause for the return Send the merchandise prepaid in its original box and with its original packing and accessories Chauvet will not issue call tags Clearly label the package with the RMA number Chauvet will refuse any product returned without an RMA number Write the RMA number on a properly affixed label DO NOT write the RMA number directly on the box Before sending the product clearly write the following information on a piece of paper and place it inside the box Your name Your address Your phone number RMA number A brief description of the problem Be sure to pack the product properly Any shipping damage resulting from inadequate packaging will be your responsibility FedEx packing or double boxing are recommended Chauvet reserves the right to use its own discretion to repair or replace returned product s Hurricane 1000 User Manual Rev T Page T3 of 14 CONTACT US WORLD HEADQUARTERS Chauvet General Information Technical Supp
8. n Contact the nearest authorized technical assistance center This product is not intended for permanent installation Use only CHAUVET water based fog fluid Drain the tank before transporting or storing the product To eliminate unnecessary wear and improve its lifespan during periods of non use completely disconnect the product from power via breaker or by unplugging it X Keep this User Manual for future use If you sell the product to another user be sure to give this document to the next owner Hurricane 1000 Make sure you use FCQ regularly no longer than 90 days between FCQ Fog Cleaner Quart was specifically developed by Chauvet to clean your cleanings to increase the life of your fogger Page 4 of 14 Furicane 1000 User Manual Rev 1 2 INTRODUCTION Overview Fuid Level Indicator Fog Fluid Tank Remote Connector Manuab Fog Button Fuse Holder Back Panel View Power Cord Hurricane 71000 User Manual Rev T Page 5 of 14 Dimensions AUT CI 3 SETUP AC Power This Hurricane 1000 has a fixed voltage power supply and it can work with an input voltage of either 120 VAC 60 Hz or 230 VAC 50 Hz depending on the specific model To determine the product s power requirements circuit breaker power outlet and wiring use the current value listed on the label affixed to the produ
9. ng usage and maintenance of this product read before using the product Always connect the product to a grounded circuit to avoid the risk of electrocution Always disconnect the product from the power source before cleaning or replacing the fuse Make sure the power cord is not crimped or damaged Never disconnect the product from power by pulling or tugging on the cord mem Do not drink or come in contact with the fog fluid If you do call your local Always make sure that the voltage of the outlet to which you are connecting the product is within the range stated on the decal or rear panel of the product The productis for indoor use only IP20 To prevent risk of fire or shock do not expose the product to rain or moisture Always install the product in a location with adequate ventilation at least 20 in 60 cm from adjacent surfaces Be sure that no ventilation slots on the product s housing are blocked Never connect the product to a dimmer or rheostat Make sure to replace the fuse with another of the same type and rating Never carry the product from the power cord or any moving part Always use the D hangingmouning bracket The maximum ambient temperature Ta is 104 F 40 C Do not operate the product at higher temperatures In the event of a serious operating problem stop using the product immediately Never try to repair the product Repairs carried out by unskilled people can lead to damage or malfunctio
10. ort Address 5200 NW 108 Avenue Voice 864 577 4455 Press 4 Sunrise FL 33351 Fax 954 756 8015 Voice 954 577 4455 Email tech chauvetighting com Fax 954 929 5560 Tollfree 800 762 1084 World Wide Web www chauvetlighting com UNITED KINGDOM AND IRELAND Chauvet Europe Lid General Information Technical Support Address Unit 16 Email lktech chauvetlighting com Brookhil Road Industrial Estate Pinxton Nottingham UK World Wide Web www chauvetlighting co uk NG16 6NT Voice 44 0 1773 511115 Fax 44 011773 511110 MEXICO Chauvet Mexico General Information Technical Support Address Av Santa Ana 30 Email servicio chauvet com mx Parque industrial Lerma Lerma Mexico C P 52000 World Wide Web www chauvet com mx Voice 52 728 285 5000 CHAUVET EUROPE Chauvet Europe BVBA General Information Technical Support Address Stokstraat 18 Email Eutech chawetighiing eu 9770 Kruishoutem Belgium World Wide Web ww chauvetighting eu Voice 43293889397 Outside the U S United Kingdom Ireland Mexico or Benelux contact your dealer Follow their instructions to request support orto return a product Visit our website for contact details Page 140114 Huricane 1000 User Manual Rav 1
11. s the same as the Manual button on the product with the addition of a READY Remote Control Paca LED FC M 1 Plug in the fog machine to power 2 Plug in the wired manual remote control to the Remote Connector socket on the back of the fog machine See the product Overview 3 Walt for the READY indicator LED to light up indicating the Hurricane 1000 is heated enough to produce fog 4 Press and hold the lt FOG gt button on the wired manual remote control 5 Release the button to stop the fog output FC M Manual Remote Control Overview reheating after a period of continuous fog output This is a normal occurrence i The FC W wireless remote allows the user to trigger the Hurricane 1000 to produce Wireless Remote iog rom up to 100 f away No receiver is required as the product has an Internal FC W receiver for the wireless remote 1 Plug in the fog machine to power 2 Allow the Hurricane 1000 3 4 minutes to heat up 3 Press and hold the lt 1 gt button on the wireless remote 4 Release the button to stop the fog output FC W Wireless Remote Overview performance EE ith thc i ed ras Huricang 1000 User Manual Rev T Pages af 1 5 TECHNICAL INFORMATION Fogger Do not allow the fogger to become clogged After every 40 hours of continuous Maintenance operation use CHAUVETB Fog Cleaner Quart FCQ through the system to prevent the i Storage accumulation of particulate m
12. sions and Weight Power Operation Fog Output Thermal Ordering Length 11 9 in 301 mm 89 in 225 mm Height Weight 8 2 in 208 mm 581b 2 7 kg Note Dimensions in inches rounded to the nearest decimal digit Power Supply Type Model specitic Parameter Consumption Operating current Fuse Power V O Power input connector Power Cord plug Heat up Time 2min Output 10 000 cm Maximum External Temp 104 F 40 C Product Name Hurricane 1000 120 V Hurricane 1000 230 V Voltage Selection Range 120 VAG 60 Hz or 230 VAG 50 Hz Foal 120 V 60 Hz 230 V 50 Hz 740 05 W 59A 35A F10 250 V F6A 250V US Worldwide UK Europe Hardwired Hard wired Edison US Local plug Tank Capacity Fluid Consumption 0 26 gal 1 01 20 mimin Cooling System Convection Item Code UPC Number 08071071 781462214197 09071072 781462214203 RoHS CEA Furicane 1000 User Manual Rev 1 Page 12 of 14 In case you need to get support or return a product RETURNS It you are located in the U S contact Chauvet World Headquarters It you are located in the UK or Ireland contact Chauvet Europe Lid It you are located in Mexico contact Chauvet Mexico If you are located in Benelux contact Chauvet Europe BVBA It you are located in any other country DO NOT contact Chauvet Instead contact your local distributor See www chauvetlighting com for distributors outside the U S UK Ireland Mexico or Bene