1. ssessss ee 35 8 Maintenance 8 1 Ice condenser chamber ccccceeeeeeceeeeee cece eee eeeeeeeeeeeeaaaaaeaeeeeeeeeeeeseeeeeneeaaees 36 8 2 Heat exchange annen secure acti evens hadi ented 36 8 3 R bb r Valves scene E EE qnae GERE C A VET ERTA E TENE N n ER 36 8 4 Vacuum eSa e A E c eeuec te teo a E euet ete coc E exe et oae ce eco a ge esee ee vare ge Een ned 36 8 5 PAIS 36 SESPEGIT Taro P 37 8 6 1 Cleaning the freeze dryer ceeeceeececeeeeeeeeeeeeeeeeeeaeeseeeeeeeeeeeeeeas 37 8 6 2 Cleaning the accessories sssssssssseee 37 8 6 3 Maintenance of the drain valve ssssssssssseseeeees 37 8 6 4 Disinfecting the drying chamber the lid and the accessories 37 8 7 Checks by the operator ssissisoniinsis iningatan naaa aaae nennen anias 37 9 IQ OQ Qualification 9 1 Installation Qualification essssseeeeeeeeene enne 38 9 2 Operational Qualification ssssssssseeeeeenennnne enne 40 9 3 SUMMARY cxcic secede danenevs dane E EAEE EE EEEE EARS 43 Operating Manual Freeze Drier Lablyo Plus and Accessories Page 4 1 General Information 1 1 Introduction What is freeze drying lyophilisation Freeze drying means Removal of water from frozen material The drying process takes place by direct conversion from ice to vapour This process is called sublimation Sublimation happens under
2. Frozen in Time a Manufacturers of Freeze Drying Machines and Vacuum Cold traps Operating Manual Lablyo PI US Lablyo Plus rg Main associated accessories Acrylic drying chamber FIT LYO 01 0 6 height shelf rack FIT LYO 03 0 6 heated shelf rack FIT LYO 19 0 4 shelf vial closing device FIT LYO 22 0 8 port flask manifold FIT LYO 13 0 48 port ampoule manifold FIT LYO 25 0 Spin Freezer FIT LYO 28 0 Vacuum pump for Lablyo Plus FIT LYO 59 0 Includes IQ OQ Qualification Contents 1 General Information USO arereliloie Er cnotedeadaatranuiue in A aaa ana aaa aai 5 LZ Applications irr edere AE inn ele RT AYUDE RAN TER ee 5 1 3 Lablyo Plus technical data 0 cece ieee eect em 6 1 4 Safety Instructions el eter aaah ean 7 1 4 1 Disconnect the mains plug sme 7 VA De SolVenhts c ree er eet hari a EET ev TH DB NN Lin aera wenden 7 1 4 3 Cleaning and Maintenance 2cccceceee ee eeeeeeseeeeeeseeeeeteeeeeenes 7 1 4 4 Freezing skin to cold SUrPACES 0 eee eect eeeeeeeeeeeteeeneeeeeeeeeeeaeens 7 1 4 5 Transport instructions cccceccceceeeeeeeeeeeeeeecaeeeeeeeeeeteeseeeeaeeaaa 7 1 5 The Lablyo Plus should not be used when sese 8 2 Information on Freeze Drying 2 1 General Information on Freeze Drying ccecceceeenececeeeeeeaeeceeeeeeteeeseeeetaas 9 2 2 cry e 11 2 93 Primary drylng cec ca
3. Vacuum Troubleshooting Guide in the User s Manual Does the system reach a displayed vacuum level of less than 6Pa in 18 hours Operating Manual Freeze Drier Lablyo Plus and Accessories Page 40 1f Temperature Graph Display The temperature graph traces on the control panel is a quick reference of the temperatures Verify these graphs are operating properly Compared to the readouts 1g Vacuum Wave Display The control panel s vacuum trace is a quick reference of vacuum level Verify this is operating properly Compared to the readouts N A ih Verify Displayed Vacuum The vacuum level indicated on the LCD display is measured between on the condenser chamber The value was calibrated at the factory by correlating its reading with that of a reference gauge The calibration was performed at a very low level approximately 10Pa NOTICE Factory calibration was performed using a precision Active Piranni Gauge calibrated to a Capacitance Manometer standard Despite the system s calibration and repeatability the readings taken at such a low level of vacuum should only be considered as a verification of a leak free system Vacuum swings can be attributed to contamination of surfaces which could take days to outgas Adjustments are discouraged Before any adjustments are made to the factory calibration of the vacuum measurement answer positively to these questions 1 Is the vacuum standard
4. Acrylic drying chamber 300mm OD Additionally requires 2x U section gaskets FIT LYO 40 0 Required if using with the Lablyo Plus 6 shelf rack FIT LYO 03 0 Heated shelves FIT LYO 19 0 Lid manifold FIT LYO 6 0 Closing device FIT LYO 22 0 FIT LYO 03 0 6 shelf rack for acrylic chamber aluminum Additionally requires Acrylic drying chamber FIT LYO 01 0 2x L section gaskets FIT LYO 40 0 FIT LYO 6 0 Lid manifold 8 port Additionally requires Acrylic drying chamber FIT LYO 01 0 2 x L section gaskets FIT LYO 40 0 8 x Quick seal valves FIT LYO 43 0 FIT LYO 9 0 Cold trap lid with hose for solvent recovery or vacuum pump protection Additionally requires 1x LU section gaskets FIT LYO 40 0 FIT LYO 12 0 Lid for drying chamber plain 320mm diameter x 20mm thick Additionally requires Acrylic drying chamber FIT LYO 01 0 2 x L section gaskets FIT LYO 40 0 FIT LYO 13 0 Column manifold 8 port Additionally requires 1x L section gaskets FIT LYO 40 0 8 x Quick seal valves FIT LYO 43 0 FIT LYO 16 0 Column manifold 16 port Additionally requires 1x L section gaskets FIT LYO 40 0 16 x Quick seal valves FIT LYO 43 0 Operating Manual Freeze Drier Lablyo Plus and Accessories Page 33 FIT LYO 19 0 Heated Shelves 6 shelves temperature controlled Additionally requires Acrylic drying chamber FIT LYO 01 0 2 x VU section gaskets FIT LYO 40 0 FIT LYO 22 0 Vial Closing Device Additionally requires
5. Acrylic drying chamber FIT LYO 01 0 2 x VU section gaskets FIT LYO 40 0 FIT LYO 25 0 Lid with ampoule manifold 48 port Additionally requires 1x UL section gasket FIT LYO 40 0 FIT LYO 28 0 Spin Freeze with 1 x set carrier plates Additionally options 1 x Extra Spin Freeze plates FIT LYO 31 0 FIT LYO 34 0 Trays 230mm for vials or tray drying x1 Additional option for the 6 shelf rack FIT LYO 03 0 Heated shelves FIT LYO 19 0 Closing device FIT LYO 22 0 FIT LYO 37 0 Vacuum hose 1m for vacuum pump Additional option for the Vacuum Pump FIT LYO 59 0 FIT LYO 40 0 L section gaskets for accessories Additional option for the Column manifold 8 port FIT LYO 13 0 Column manifold 16 port X FIT LYO 16 0 Lid manifold 8 port FIT LYO 25 0 Acrylic drying chamber FIT LYO 01 0 Lid for drying chamber FIT LYO 12 0 FIT LYO 43 0 Quick seal valves Additional option for the Column manifold 8 port FIT LYO 13 0 Column manifold 16 port FIT LYO 16 0 Lid manifold 8 port FIT LYO 16 0 Operating Manual Freeze Drier Lablyo Plus and Accessories Page 34 7 Troubleshooting 7 1 Power failure The refrigeration and vacuum pump will restart after a power failure In the event of a power failure in the drying phase the batch may become unusable Whether the batch can be saved or not depends on the drying phase the product was in when the power failure occurred If power returns within a few minutes then it is unlikely that any
6. L k L b 4d k d d Tray eceding ice core pata LN S blim tion oo Soe xd Front 30 C 4 Contact heat transfer Shelf Heat transfer takes place via the heated shelves by direct contact with the bottom of the tray At the beginning of sublimation the transfer of heat is very effective from the wall of the tray to the frozen product However soon an area develops which is ice free porous dried and has an insulating effect between the wall of the tray and the product This slows down the heat energy transfer available to the ice core The porous dried layer enables the passage of vapour from the ice core If it is restricted the temperature will increase and ice core will thaw rather than sublimate This applies especially to inhomogeneous products and to great layer thicknesses During this drying phase it is important to regulate the heat supply and control temperature and pressure precisely Operating Manual Freeze Drier Lablyo Plus and Accessories Page 13 2 4 Secondary drying The final pressure in the drying chamber depends on the ice condenser temperature according to the vapor pressure curve above ice e g 1 030 mbar correspond to 20 C 0 370 mbar correspond to 30 C 0 120 mbar correspond to 40 C 0 040 mbar correspond to 50 C 0 01 mbar correspond to 60 C The unit is in operating condition if the temperature of the ice condenser is lower than 50 C and the pressure is lower than 0 12 mbar The final
7. and size of L section gaskets to make the vacuum seal 2d Vacuum Install the vacuum pump per the Users Manual Is the Y Pump pump attached to the vacuum port at the top of the Installation chamber with the correct rubber hose and clamps provided Vacuum Is the vacuum pump plugged into the rear of the freeze Y Pump dryer and the pump s power switch turned to the ON 2e Electrical position Vacuum The vacuum pump s ballast should remain closed Is Y Ballast the pump s ballast closed Electrical Plug the freeze dryer into a dedicated electrical outlet Y Connection Has the electrical service been verified to be adequate in size and voltage The ID plate on the rear of the freeze dryer has the electrical requirements 2e Electrical Has the ground on the electrical service been verified Y Grounding Operating Manual Freeze Drier Lablyo Plus and Accessories Page 39 9 2 Operational Qualification Step Description Specification or Acceptance Criteria Result 1 Freeze Drier 1a Condenser Chamber Refrigeration With the freeze dryer system at ambient temperature turn the Main Power Switch Switch on Condenser Chamber Cooling Does the refrigeration system start Record the time it started Y N Power to Vacuum Pump Press the button labeled Vacuum Pump Does the vacuum pump start Record the time it started Refrigeration Effectiveness Does the condenser chamb
8. being used to verify the freeze dryer accepted by the organization to be precise and has it organization to be precise and has it been calibrated recently 2 Is the level of accuracy we are attempting to reach pertinent to the freeze drying applications Does the vacuum display correlate to the reference gauge Ref Instrument If vacuum is to be calibrated contact Labconco Product Service for calibration procedure N A li Defrost With the refrigeration switched OFF press the defrost button ON Does the condenser chamber become warm to the touch N A Operating Manual Freeze Drier Lablyo Plus and Accessories Page 41 2 Routine Below are helpful hints to be included in the organization s Maintainance preventive maintenance plan 2a Vacuum Vacuum grease should be applied to rubber Y Grease components as required In general vacuum grease should be the first step in trouble shooting vacuum leaks Thin layers of grease are adequate for all seals Only use grease specially formulated for low vacuum service Is vacuum grease readily available and documented Type of grease used 2b Vacuum The vacuum pump oil should be changed as needed Y Pump Change oil that appears cloudy or discolored At a Oil minimum oil should be changed every 1000 hours of service Has there been a preventive maintenance plan established for the vacuum pump Type of oil to be us
9. flasks should be rotated in a freezer bath This causes the frozen material to form a thin layer lining the flask These procedures will help minimize the drying time It is advisable to pre cool the shelves in order to avoid partial thawing during the evacuation Products containing solvent high salt or sugar concentrations require freezing to lower temperatures 2 3 Primary drying The Lablyo Plus is taken to its operating temperature The vacuum pump is switched on The duration of the main drying phase depends mainly on the layer thickness of the product the solid content of the product the heat supplied to the product during the drying process the vacuum pressure inside the drying chamber during the drying process With increasing pressure the rate of sublimation rises as long as it stays below the vapour pressure of the product This is because at higher pressures the heat energy reaches the sublimation front of the ice core sooner Therefore the drying period is shortened The water vapor generated during the main drying phase is not intended to be removed by the vacuum pump It is to be collected by the ice condenser The purpose of the vacuum pump is to lower the partial pressure of the non condensable gases so that the water vapor can be transported from the product to the ice condenser However small quantities of water vapor will be removed by the vacuum pump The vacuum pump is equipped with a gas ballast valve th
10. heated or standard shelves The trays can then be lowered into the product chamber to freeze A blank lid can be placed on the top of the chamber to keep warm air and moisture from entering while the product is freezing The same principle can be used for tray drying although more care is needed when stacking the trays 3 1 2 Freezing in an external freezer The product is prepared in vials or trays and then placed in a 40 C freezer until it is completely frozen 3 1 3 The Spin freezer The spin freezer prevents foaming when vacuum freezing is used It does this by using centrifugal force The long thin ampoules sit at an angle with the tops facing in slightly towards the centre The vials are left to spin on an adjustable timer while the vacuum is applied The centrifugal force will stop the product from overflowing and a long thin tapered layer will freeze up the side of the slanting ampoule maximizing the surface area 3 1 4 Flask freezing in a glycol bath The flasks should only be partly filled then rotated in the freezing glycol so a thin layer freezes evenly around the inside of the flask to maximize the surface area Operating Manual Freeze Drier Lablyo Plus and Accessories Page 15 3 2 1 Drying on plain shelves Vials bottles trays or dishes containing frozen product are arranged on the shelves and lowered into the acrylic chamber These shelves are ideal for product that requires slow drying with minimal heat inp
11. or removed from the manifold while the refrigeration and vacuum pump are running When adding a flask to a manifold that is under vacuum it is important to close the valves on the other flasks that are in use Open the valve to the newly introduced flask and after a few minutes the rest of the valves can be reopened 3 2 6 Freeze drying with a 48 port ampoule manifold The 48 port ampoule manifold requires that all 48 ports are used at once Ampoules from the spin freeze are a push on seal to the rubber nipples When the frozen the ampoules are attached then will freeze dry from the vacuum and the ambient heat Once the product is dry the ampoules can be removed and sealed The ampoules are usually hermetically sealed using a flame to melt the glass tube while it is being twisted Operating Manual Freeze Drier Lablyo Plus and Accessories Page 17 4 Installation and Commissioning of the Unit 4 1 Site of installation In order to ensure the air circulation of the heat exchanger do not place any paper cloths or similar items behind the unit The freeze dryer should be positioned horizontally The ambient temperature should be between approx 5 C and 30 C The refrigeration compressor of the freeze dryer is air cooled Sufficient air circulation must be ensured A distance of at least 30cm to the wall should be kept The unit should not be positioned near radiators or heat sources In the case of insufficient air circulation
12. pressure measured when there is no product in the unit and its corresponding ice temperature is determined by the warmest ice surface in the condenser chamber 2 5 End of drying and air admittance The product is dry when it at or above ambient temperature while under the secondary drying vacuum level The condenser temperature will also be lower than when under load The vacuum pump can be switched off and the condenser chamber drain valve can be opened as an air admittance valve This valve can be used to purge the unit with nitrogen or another inert gas instead of using air Then the unit is switched off and the product is removed 2 6 Defrosting Defrosting of the ice condenser is carried out by switching off the refrigeration and switching on the red defrost button To let the water out the open the drain valve and allow to drain into an appropriate container The defrost is self regulating and will not overheat Operating Manual Freeze Drier Lablyo Plus and Accessories Page 14 3 Description of the Freeze Drying Processes 3 1 Freezing the product There are 4 ways to freeze the product when using the Lablyo Plus 1 Directly inside the Product Chamber 2 A laboratory freezer preferably 40 C 3 The Spin freezer 4 Flask freezing in a glycol bath 3 1 1 Freezing inside the product chamber Product can be loaded into the freeze drier in an unfrozen state This would be done in trays on shelves either closing device shelves
13. vacuum when the temperature in the product is less than 10 C The aim of freeze drying is to obtain a readily water soluble product which has the same characteristics as the original product after the addition of water As the drying process takes place in the frozen state at low temperatures it is possible to dry proteins which will not denature Most of the other chemical compounds will also remain unchanged Freeze drying products of biological origin such as tissues tissue extracts bacteria vaccines and sera transforms them into a dry product During this process enzymatic bacterial and chemical changes are largely avoided Freeze drying is the gentlest process for preserving the biological properties of sensitive tissue and tissue components Freeze drying can also be used for dry some inorganic products 1 2 Applications The Lablyo Plus is a laboratory and pre production machine for the freeze drying of products in ampoules vials glass flasks bottles or dishes The initial freezing of the products will require a spin freezer flask freezing bath laboratory freezer or in some cases the pre freezing of the products can be done in the Lablyo Plus chamber The appropriate accessories are required for freeze drying can be made with the use of the Operating Manual Freeze Drier Lablyo Plus and Accessories Page 5 Lablyo Plus 1 3 Technical data of freeze dryer Performance data 55 C Ice condenser capacity 3 kg max
14. Ice condenser 2 kg per 24 hour performance maximum Physical data Dimensions of the unit width 9000 mm height 500 mm depth 630 mm Weight approx 48 kg Noise emissions according to DIN 45635 54 dB A Condenser Chamber Dimensions 200mm x 230mm Product Chamber Dimensions 300mm x 380mm Electromagnetic compatibility according class B to EN 55011 Refrigerant R507 0 65KG Voltage 240V 50Hz 220V 60Hz special order Main fuse rating 13 Amp Ambient temperature 5 C to 30 Equipment connections Vacuum connection 19mm nozzle Drain valve 1 4 BSP ball valve Electrical connection IEC connection Operating Manual Freeze Drier Lablyo Plus and Accessories Page 6 1 4 Safety instructions 1 4 1 Disconnect the mains plug before removing panels The mains plug must be disconnected before the panels are removed or any maintenance work is undertaken 1 4 2 Solvents Acidic or high solvent concentration products should not be dried because of corrosion risk and damage to the vacuum pump 1 4 3 Cleaning and Maintenance of the Unit For infectious toxic pathogenic and radioactive substances the danger information of the associated safety regulations must be observed 1 4 4 Freezing of skin to surfaces Make sure skin does not come into contact with freezing surfaces Skin can only be detached from the surf
15. L Section Gasket Cm Z m Lably o Plus www freezedriers com Frozenin Time ra FIT LYO 19 0 Additionally requires Acrylic drying chamber FIT LYO 01 0 2 x VU section gaskets FIT LYO 40 0 6 x Trays 230mm FIT LYO 34 0 Heated Shelves 6 shelves temperature controlled Acrylic lid with hieu leadthroughs 7 OLC Section Gasket Heater control Ld SS ca Laplyo Plus www freezedriers com L Section Gasket Vacuum Hose J S Frozen in Time La E Vacuum pump e T Vacuum pump Vacuum Hose Ay n Operating Manual Freeze Drier Lablyo Plus and Accessories Page 23 4 7 5 8 port column manifold Column manifold Rubber valve Glass flasks v Glass tube E IE E Section Gasket Vacuum Hose o Plus ILL LN Lably www freezedriers com M Frozen in Time ra Vacuum pump FIT LYO 13 0 Column manifold 8 port Additionally requires 1x L section gaskets FIT LYO 40 0 8 x Quick seal valves FIT LYO 43 0 Operating Manual Freeze Drier Lablyo Plus and Accessories Page 24 4 7 6 8
16. ace by applying heat Do not use liquid 1 4 5 Transporting The Lablyo Plus should be carried by two people and care must be taken when placing the unit down on a surface not to trap fingers Operating Manual Freeze Drier Lablyo Plus and Accessories Page 7 1 5 The Lablyo Plus should not be used when 1 It is not properly installed 2 The lid or accessories are not properly installed 3 Panels are missing 4 The operator is not authorized or trained 5 Highly corrosive or solvent substances are present 6 The accessories are not designed to be used with the unit or show signs of damage Glassware can be susceptible to implosion causing potential risk during freeze drying 7 In hazardous or dangerous locations 11 The products are explosive or highly flammable 12 The products are Infectious toxic pathogenic or radioactive unless in suitable vessels and in accordance with the relevant safety data Operating Manual Freeze Drier Lablyo Plus and Accessories Page 8 2 Information on Freeze Drying 2 1 General Information on Freeze Drying Freeze drying is the gentlest process for drying products It uses the process of sublimation the direct conversion from solid to gaseous state The frozen product is dried under vacuum without thawing The condenser chamber works as a cryogenic pump as it takes large quantities of vapour and condenses it to ice The vacuum pump is only intended to remove the air from the drying chamb
17. as been just switched off There is a delay and countdown timer shown in the red indicator Operating Manual Freeze Drier Lablyo Plus and Accessories Page 28 5 2 Graph The right hand side Y axis of the graph shows the temperature Across the X axis it shows the time in hours The left hand side of the Y axis shows the vacuum level in Pascals The right hand side of the screen is where you can select which information you would like to appear on the graph the button colour indicates the trace on the graph Sraph Operating Manual Freeze Drier Lablyo Plus and Accessories Page 29 5 3 Program Steps Recipe 1 Vacuum Stey 2 Final ste 1 The program steps create a recipe to allow simple automation of the product chamber temperature using time to initiate the change in temperature Several Recipes can be saved and entered in the top left box The operator can choose within which step the vacuum will be applied in the centre top middle box There are 40 available recipe steps but it unlikely that all of them will be required Use as many steps as is needed and indicate the last one in the box Final step By selecting one of the steps numbered 01 to 40 in the blue table it will become highlighted Give the highlighted step its time frame and temperature level in the larger box on the right When all steps have been programmed as planned press Save To return to the main screen press Return Operating Manual Freez
18. at the there is no ice or water inside the condenser chamber Dry the chamber with a cloth To test the Lablyo Plus connected to the vacuum pump and put a blank lid and seal on the mouth of the chamber It will not achieve the same level of vacuum as a direct reading off the pump but it should probably be lower than 0 1 mbar The next thing to do would be to fit the accessory if it is a manifold with rubber valves then these should all be closed If itis a 48 port manifold then all 48 ports need to blanked off or fit with ampoules All accessories with acrylic chambers need to be assembled complete To check the vacuum pump directly it is necessary to use a separate vacuum sensor Make sure that the vacuum pump is warm and there should be a vacuum reading of 0 04 mbar or less 7 3 Unit does not work If the indicator light does not work and the refrigeration system is not running after the mains switch has been activated the following tests must be performed Check that the Lablyo Plus is plugged in Check the breakers or fuses for the circuit Check the plug fuse 7 4 Insufficient ice condenser temperature The refrigeration will stop if the ambient temperature is too high or the airflow is restricted to the heat exchanger Once the permissible operating conditions are reached again the refrigeration unit is switched on automatically via the motor protection switch or via the pressure switch The minimum ice condenser temperature of approxi
19. at when open removes traces of condensable vapors from the pump For this reason the gas ballast valve can be open during the main primary phase The gas ballast valve is not required for secondary drying and closing it will help achieve a lower level of vacuum During primary drying the moisture is removed by sublimation and during final drying the bound moisture is removed by desorption The recommended vacuum pump should reach with open gas ballast valve a vacuum level lower than the relevant water vapour pressure Operating Manual Freeze Drier Lablyo Plus and Accessories Page 11 The residual moisture of the dried product depends mainly on The temperature of the dried product during the final drying process The final vacuum reached during the final drying process The end of the primary drying phase is reached when the product temperature is nearly the same as the shelf temperature temperature difference between shelf and product approximately 3 to 5 C Once the primary drying is completed the secondary drying will remove the bound water from the product The following diagram shows the drying process for a product containing approximately 10 96 solid matter During the first quarter of the primary drying phase 5096 of the water content is condensed During the next quarter of the primary drying phase 5096 of the remaining water content is condensed This continues until the drying curve approaches the time axis asymptotically Thi
20. avy cere rete eire eet ne nis etae Pa e dde Eae qe beta end de Ete es 11 2 4 Secondary dryilig uitia aee eerte e eue v se Vade Eea 14 2 5 End of Process 0 0 cceeeeeceeeeeeeseeeeeeeeeceeeeeeeeeneeeeeeseneaeeeeseneaeeeeeseeaeeeeeenaaees 14 ZAMBIE 14 3 Description of the Freeze Drying Processes 3 1 Freezing the product 2 oca eec eae A edward deletes 15 3 1 1 Freezing samples inside the ice condenser sssus 15 3 1 2 Freezing in an external freezer 15 3 1 3 Freezing with a spin freezer esses 15 3 1 4 Flask freezing in a glycol freezer bath sess 15 3 2 Drying the product ciui ecd sete pe termed o pai sex d Pena ES 16 3 2 1 Drying on plain SHEIVES 0 cece ete e eee ee m 16 3 2 2 Drying on heated SHEIVES 0 cece ee eee eee e ee ee eects eee eeeeeeeaeeees 16 3 2 3 Drying in a vial closing GEVICE 0 cece ee eee ee eee eee ee ee eeeeneneaes 16 3 2 4 Drying in a vial closing device with heated shelves 16 3 2 5 Drying with a drum column or lid manifold sssss 17 3 2 6 Drying with a 48 port ampoule manifold sssssssse 17 4 Installation and Commissioning of the Unit 4 1 Site of installation nnne enne nnne 18 AD Mans DOW IEEE 18 4 3 Air Adrmilttance eiecit o Pc RR RE Sue RR Ren RARE ERRR RC ERR ENRREE 18 4 4 Condensate and d
21. damage will have occurred It is important to distinguish between the primary drying phase and the secondary drying phase The product is in the secondary drying phase if the residual moisture has reached approximately 5 Below this value the product is generally not damaged by a power failure If the product is in the primary drying phase we recommend removing it for refreezing It is advisable to defrost the condenser chamber at this point If the product is considered to be still usable then it can be placed back in the freeze drier and the process can be started again 7 2 Insufficient vacuum 7 1 1 Easy initial checks Check that the drain valve is closed Remove the accessory and seal the top of the condenser chamber with a blank lid and a lightly greased L section gasket If the lid now seals it indicates that there is a leak in the accessory If the lid does not seal then the drain valve vacuum hose or vacuum pump is at fault Check that the vacuum pump is running and that there is suction If there is check that the hose push on connections between Lablyo Plus and vacuum pump are tight Make sure that the drain valve is not leaking by checking for suction when it is closed If the accessory is leaking examine every port and push on fitting Lightly grease any sealing parts and press down on chamber or manifold in order to assist the sealing gaskets 7 1 2 Checks to make using the vacuum readout The following steps require th
22. driers com Frozen in Time ra Vacuum pump am m i Operating Manual Freeze Drier Lablyo Plus and Accessories Page 20 4 7 2 48 port ampoule manifold 48 port manifold 7 Push on ee ET _ Acrylic lid Ampoules ampoules nipples mp 44V Section Gasket Vacuum Hose o Plus Lably www freezedriers com M Frozen in Time ra Vacuum pump e FIT LYO 25 0 Lid with ampoule manifold 48 port Additionally requires 1x L section gasket FIT LYO 40 0 c Operating Manual Freeze Drier Lablyo Plus and Accessories Page 21 4 7 3 Spin freezer Acrylic chamber Ampoules Ampoule plates E Section Gasket Acrylic lid v gp N _ Motor controler Vacuum Hose Lablyo Plus www freezedriers com L M Frozen in Time ra Vacuum pump FIT LYO 28 0 Spin Freeze with 1 x set carrier plates Includes L section gasket Additionally options Extra Spin Freeze plates FIT LYO 31 0 Operating Manual Freeze Drier Lablyo Plus and Accessories Page 22 4 7 4 Heated shelves _ Heater shelves _ Acrylic lid __
23. e Drier Lablyo Plus and Accessories Page 30 5 4 Historic Data Historic Data 90150329 12503l csv Data files get created for upto every 24 hours of run time These files can be saved onto a USB stick or can be used within the control system to create a graph e Select a file and press Confirm Historic Graph Scroll back and forth to see the full time frame Select or deselect to show the traces that are most important Operating Manual Freeze Drier Lablyo Plus and Accessories Page 31 5 5 Defrost Defrost is not part of the control panel The red illuminated switch on the side activates the defrost Defrost will always be overridden by the refrigeration Defrost should only be switched on to defrost ice and it must then be switched off However the defrost heater is self regulating and will not over heat 5 6 Drain valve The drain valve should be closed whenever the vacuum pump is activated It should not be opened while the vacuum pump is still switch on The drain valve is used to drain defrosted condensate from the condenser chamber It is also used to admit air or inert gases into the condenser chamber to break the vacuum 5 7 Vacuum connection The IEC socket connection at the back of the unit is used to power a vacuum pump through the Lablyo Plus making use of the control panel functions Operating Manual Freeze Drier Lablyo Plus and Accessories Page 32 6 Accessories and part numbers FIT LYO 01 0
24. ed 3 Personnel Training 3a User Training Have personnel that will use the Lablyo Plus freeze Y Related to drier been adequately trained Equipment Are personnel familiar with All the buttons and displays on the front Collector capacity limits before defrosting Defrosting and draining methods Safe handling of solvents drained The use of vacuum grease Opening closing and venting sample valves Cleaning of the freeze dryer and neutralization of acids 3b User s Are the personnel who are to use or maintain Y Manual the Lablyo Plus able to locate the User s Manual for the machine Operating Manual Freeze Drier Lablyo Plus and Accessories 9 3 Summary Lablyo Plus freezedrier IQ OQ Document Equipment Location FreeZone Ser No Model No User Protocol Revision or Date published Contact print name Title Review the Response columns for answers of NO Use the area below to describe the deficiency or unacceptable results Those deficiencies are to be followed with an instruction for Corrective Actions Once acceptable results are obtained the deficiency is accepted by signing the Corrective Action Step Deficiency followed by Corrective Action Signature Operating Manual Freeze Drier Lablyo Plus and Accessories Page 43
25. efrosting water sssssssssseeeeeens 18 4 5 Vacuum pump exhaust gases sssssssssseeee eene nnne 18 LEJENIIEIECISU EE 19 4 7 Installation of accessories sssssssess seem emen 20 4 71 Vial ClOSING device oiii iecit Tee ree ese 20 4 7 2 48 port ampoule manifold sssssssssseee 21 4 7 3 SPIN MECZE ATE 22 4 7 4 Heated shelves 1e ge ig edn nee La regu ied ec 23 4 7 5 8 port column ManNifOld cece cece eee eee eee teat eee eeeee ee eeees 24 4 7 6 8 port lid Manifold ccc eee mH 25 ALT Shelf TACKS cick sence ocio ene deca eieedanale lesson cU E Ed eels 26 Operating Manual Freeze Drier Lablyo Plus and Accessories Page 3 5 1 Switching the Unit On cecus eter neret ee metere en ee una EAE 27 Neri pem 29 5 9 Program Steps rec tre pen tue ipee e E EEEE nO ERR e T EROR TE 30 S Edslzieg dBri PE 31 5 5 Defrost METER 32 5 6 Drain V l ese erener a a aA a o a a 32 5 7 VACUUM conrnectlon tiep oa a a e a MR ERN 30 6 Accessories and part numbers sssssssssssssss 33 7 Troubleshooting PAZ Power fallUre oreet idee scuscitoces tete eed t eoe tot Sedes oce ecd Eee ae dacs 35 7 2 Irnisufficient vacuum serinin evene oL inne OE Ee en aen ma waascnee stacbacwcsenaneteneunty 35 FS Unit does not WOIK rete toes reete edt e ced nt dares Decus eC n X A NA 35 7 4 Insufficient ice condenser temperature
26. er but not the vapor In order to start the sublimation process energy must be supplied to the product When drying takes place in glass flasks on a manifold the heat energy is taken from the warmer surrounding air When drying takes place on shelves in an acrylic chamber the heat energy source is radiation from the environment and directly by from the shelves if they are heated Primary drying removes the most of the water from the product Secondary drying removes the last traces of water means of deep vacuum The main components of a freeze dryer are e Vacuum drying chamber or manifold a plain or heated shelves for drying in dishes b shelves with sealing device for drying in vials or small bottles C rubber valves for connecting round bottom flasks bottles etc d rubber nipples for connecting ampoules e Vacuum pump to evacuate air e ce condenser with a temperature of 55 C or 85 C to condense vapour Sublimation The principle of sublimation is briefly explained using the phase diagram of solid liquid and vapour If the pressure is higher than 6 1 mbar water passes through all three phases solid liquid vapour when the temperature is lowered or raised At 6 1 mbar and 0 C all three lines meet this is called the triple point where all three phase can occur simultaneously Below this point when the pressure is lower than 6 1 mbar the ice is converted directly from a solid to a vapour on reaching the sublimation pressure cur
27. er temperature reach 40 C in less than 40 minutes With the system under vacuum and 21 C ambient temperature NOTE Freeze Dryers are tested to 50 C or in the factory Conditions may vary in the field resulting in warmer acceptance temperatures Product Shelf Chamber Refrigeration Set the Product Chamber Cooling to Does the refrigeration system start Record the time it started Verify Displayed Temperature The temperature indicated on the display is measured on the collector coil There is a mobile probe that hangs free inside as well The values were calibrated at the factory by correlating its reading with that of a reference gauge attached to a sensors Does the display correlate to the reference Gauge 200 Ref Instrument If the temperature does not correlate contact Frozen in Time 01347 878158 N A Vacuum Leaks Verify that the system is leak free by continuously running the vacuum pump with the refrigeration system ON The rate the freeze dryer without samples achieves a low level of vacuum less than 13 Pa it is dependent upon many factors Inside volume amp surface area of the system Cleanliness or cleaners used on interior Condition amp size of the vacuum pump Period of time the parts have been exposed to environmental conditions Based on the freeze dryer s displayed vacuum level the freeze dryer should reach its lowest level in less than 18 hours If not refer to
28. eze Drier Lablyo Plus and Accessories Page 26 5 Using the Lablyo Plus 5 1 Switching on the unit Switch the Lablyo Plus on at the power switch on the rear of the unit The indicator light should now be on The control panel should also now be active The screen on start up shows the Main Menu On the right there is Shelf chamber temperature Mobile probes 1 to 4 temperatures Condenser temperature Vacuum level in Pascals Shelf 90 0 c Lus Probe 1 70 0 cC Probe 2 50 0 cC On the left top 5 there are buttons to control e Condenser Cooling Vacuum Pump Vacuum Sensor Shelf Cooling Jump to step to be used to advance steps during an automated program In the centre we have the Run Status table e Work Mode Stop when off and Run when the program is running Run time Recipe number Current step that is running Target Temp for the current step Remaining Time for the whole program Power on time since last time the unit was switched on Operating Manual Freeze Drier Lablyo Plus and Accessories Page 27 Shelf 90 0 C Probe i 70 0 C ded Along the bottom row we have the following buttons e Start to start up the program in the above table e Pause to temporarily stop the running of the current program e Graph will show the graph with the current data e Program this enables the operator to program a recipe for an automated cycle The refrigeration compressor will not start straight away if it h
29. mately 55 C or 85 C is reached when the ice condenser is not under load Sufficient air circulation is very important Do not place any objects behind the unit Operating Manual Freeze Drier Lablyo Plus and Accessories Page 35 8 Maintenance 8 1 Ice condenser chamber Before each start up ensure that all water residues have been removed from the ice condenser chamber If necessary wipe the ice condenser chamber dry Before every drying process it is recommended to open and close the drain valve 8 2 Heat exchanger The refrigeration heat exchanger is used to cool the refrigerant compressed by the refrigeration unit The heat exchanger is located at the back of the unit and should be checked for dust or dirt residues every few months It must be cleaned whenever necessary The heat exchanger can be cleaned best by brushing by using a vacuum cleaner from the outside or by using compressed air from inside of the unit Excessive build up on the heat exchanger leads to a decrease in performance and may cause a failure of the unit 8 3 Rubber valves and seals Special attention must be paid to the rubber valves If the valves are stiff they must be dismantled cleaned slightly greased with vacuum grease and reassembled 8 4 Vacuum pump For the maintenance of the vacuum pump please refer to the separate operating manual Additionally we would like to emphasize the following points The oil level of the vacuum pump must be reg
30. or too high ambient temperatures the temperature and the pressure in the refrigerating system will increase If the maximum permissible operating pressure is exceeded this may cause the refrigeration unit to switch off The following connections are required at the site 4 2 Mains power The operating voltage on the name plate must correspond to the local supply voltage Frozen in Time freeze dryers are units of safety class The Lablyo Plus has a three wire connection cable with a 230VAC 13 amp fused plug earth contact The freeze dryer must be on a circuit protected with a 16 Amp fuse or circuit breaker 4 3 Air admittance Drain valve The drain valve is also used for air admittance If bottles have to be sealed in nitrogen the ice condenser chamber can be purged through the drain valve Take care not to over pressure the system 4 4 Condensate and defrosting water The condensate and the defrosting water are discharged through the drain valve 4 5 Vacuum pump exhaust gases The oil mist from the vacuum pump is normally trapped in an exhaust filter If this is not the case the oil mist has to be discharged A hose can be connected to the exhaust flange of the vacuum that leads into the open air or a vent During installation of the pipe special care must be taken that condensate cannot flow back into the pump Operating Manual Freeze Drier Lablyo Plus and Accessories Page 18 4 6 Initial start up Prior to start up make s
31. port lid manifold E Section Gasket Glass flasks Acrylic Chamber zm y Rubber valve Y Glass tube 4 V Section Gasket Vacuum Hose Labtyo Plus www freezedriers com h Frozen in Time ra Vacuum pump i e FIT LYO 6 0 Lid manifold 8 port Additionally requires Acrylic drying chamber FIT LYO 01 0 2 x VU section gaskets FIT LYO 40 0 8 x Quick seal valves FIT LYO 43 0 Additionally options 6 shelf rack FIT LYO 03 0 6 x Trays 230mm FIT LYO 34 0 c To use the Lid manifold as a plain lid without valves it can be turned upside down Operating Manual Freeze Drier Lablyo Plus and Accessories Page 25 4 7 7 6 shelf rack for acrylic chamber aluminum IE pee Acrylic lid BE L Section Gasket 6 Shelves Rack a V Section Gasket Vacuum n 1 Hose plus Frozen in Time ria Lablyo www freezedriers com Vacuum pump FIT LYO 03 0 6 shelf rack for acrylic chamber aluminum Additionally requires Acrylic drying chamber FIT LYO 01 0 2x L section gaskets FIT LYO 40 0 Lid for drying chamber FIT LYO 12 0 Additionally options Lid manifold 8 port FIT LYO 6 0 4 x Trays 230mm FIT LYO 34 0 Operating Manual Fre
32. rotocol is solely intended to be used with Lablyo Plus freeze driers which are new or relocated It is written to assist the end user in validation of predetermined specifications The protocol begins with planning the site for the piece of equipment and therefore is of value prior to receipt of delivery The use of this document does not replace the need for the Lablyo Plus User s Manual and is in this case attached Information within the User s Manual is required to complete this IQ OQ Protocol If the manual has been misplaced copies can be obtained from the manufacturer or down loaded from their website www freezedriers com 9 1 Installation Qualification Description Specification or Acceptance Criteria Result Step 1 Site Planning 1a Space Requirements Refer to 1 3 Technical data of freeze dryer Check in the User s Manual for dimensions of the model you have chosen Has adequate floor or counter space been provided for placement of the equipment A minimum of 100mm is required between the back of a freeze dryer and the wall and between the sides and the walls for proper airflow through the refrigeration system Electrical Service Refer to the User s Manual for electrical requirements Are services available for the equipment to be connected to an electrical circuit of adequate size and the proper voltage Vacuum Pump Refer to the User s Manual Have accommodations been made to p
33. rovide a suitable vacuum pump It must be capable of at least 100 Liters min With an inlet fitting suitable for a 34 inch ID vacuum hose on one end and a KF25 on the other It must have the same voltage rating as the freeze dryer And have the means to be powered by an IEC connection An oil mist eliminator exhaust filter is recommended Accessories Freeze drying chambers or manifolds are not included with the freeze dryer Has an appropriate accessory been purchased to complete the required freeze drying process Y JIN N A Operating Manual Freeze Drier Lablyo Plus and Accessories Page 38 2 Prior to operation 2a Damage Have the delivered products been inspected fo any Y Claims signs of damage that may have occurred while in transit Keep packaging materials until inspection is complete WARNING Do not attempt to pull a vacuum on a freeze dryer with any damage to any of the accessories manifolds chambers etc Implosion and potential for injury can occur If damaged contact Frozen in Time 01347 878158 or the distributer from whom it was purchased 2b Handling Has the Safety Officer or equivalent reviewed the safe Y Solvents handling and disposal of solvents trapped as well as N A used vacuum pump oil 2c Manifold Place the desired drying chamber or manifold on to the Y Installation top of the Lablyo Plus condenser chamber flange N A Do you have the correct number
34. s typical drying curve is due to the fact that the area of sublimation recedes into the product and the remaining water vapour must pass through the already dried layers During the drying process the resistance increases The drying curve is determined by the latent heat of sublimation and the amount of vapour transported In order to increase the specific heat conduction properties of the product and to keep the water vapour volume as low as possible it is necessary that drying takes place as close as possible to the solidification point or eutectic point Primary Drying Secondary Drying 1004 o c E i 6 4 9 d 50 l 5 NO T 0 r r 0 10 20 24 30 Time in Hours The drying time depends heavily on the vacuum level The nearer the vacuum to the solidification point in accordance with the vapor pressure curve the shorter the drying time Operating Manual Freeze Drier Lablyo Plus and Accessories Page 12 Facts regarding ice in a vacuum 1 0 gram of ice at 1 0 mbar assumes a volume of 1 m vapor 0 1 mbar assumes a volume of 10 m vapor 0 01 mbar assumes a volume of 100 m vapor Heat supply during drying The required heat supply to the product to be dried takes place by Conduction through contact in the drying chamber Mild conduction through low pressure vapour Radiant heat energy Affects of freeze drying of a product in a dish Radiant heat Radiant heat 1 Vaporization Product N i
35. ularly checked at the sight glass in case of continuous operation at least once a day Top up oil to the required level via the oil inlet Due to possible operation with gas ballast oil consumption cannot be avoided For topping up see the operating manual of the pump The oil change should always be carried out with warm pump 8 5 Exhaust filter If the unit is equipped with an exhaust filter necessary if the exhaust gases cannot be extracted into the open air or into a vent take care that the condensate in the filter does not rise too high Operating Manual Freeze Drier Lablyo Plus and Accessories Page 36 8 6 Cleaning 8 6 1 Cleaning the freeze dryer Use soapy water or other water soluble mild cleaning agents to clean the freeze dryer Avoid corrosive and aggressive substances Do not use alkaline solutions or solvents or agents with abrasive particles Remove product residues from the ice condenser chamber using a cloth It is recommended to open the lid of the condenser chamber when the freeze dryer is not in use so that moisture can evaporate If there is the risk of toxic radioactive or pathogenic contamination special safety measures must be considered and adhered to 8 6 2 Cleaning the accessories When cleaning accessories special safety measures must be taken as these are measures to ensure operational safety and reliability Cleaning of accessories should be carried away from the freeze dryer once a week or preferabl
36. ure that the freeze dryer has been properly set up and installed Actylic lid _ Acrylic lid mm mm Vacuum Hose POE Lab www freezedriers com Frozen in Time ua Vacuum pump Ju L E e LJ LJ TL Installation of the vacuum pump The vacuum pump can be powered through the Lablyo Plus via the IEC socket on the left hand side Make sure that the vacuum exhaust gases are filtered or carried off Operating Manual Freeze Drier Lablyo Plus and Accessories Page 19 4 7 Installation of accessories 4 7 1 Vial closing device _ Operating handle l _ Acrylic lid e LET ME Vacuum lr 1 Hose cabo PMS ERO Frozen in Time La www freezedriers com Vacuum pump FIT LYO 22 0 Vial Closing Device Additionally requires Acrylic drying chamber FIT LYO 01 0 2 x VU section gaskets FIT LYO 40 0 4 x Trays 230mm FIT LYO 34 0 P Operating handle 5 Acrylic Chamber 7 Section Gasket mmeemmHhmemmn Closing device Viale Jmeenenhnnnnn si AARRAAAAARAAA Vial Ti Acrylic lid L Section Gasket N He lal Trays EN ERE NY T y Vacuum i y Hose o Plus Lably www freeze
37. ut or small volume drying 3 2 1 Drying on heated shelves Vials bottles trays or dishes containing frozen product are arranged on the shelves and lowered into the acrylic chamber These shelves are ideal for product that requires faster drying or higher temperatures Each shelf is has equal heat input and there is a temperature sensor sampling one shelf r1 only Product should be loaded equally over all the shelves to allow for even drying rates There are leadthroughs in the lid for the temperature sensor and power supply The Lablyo Plus requires a separate temperature controller 3 2 3 Drying in a closing device The closing devise is a series of shelves also for use inside an acrylic chamber Trays of frozen product are loaded onto it is then lowered into the chamber When the product is dry the lids on the vials can be closed sealing in either a vacuum or a nitrogen charge To do this the handle is turned clockwise to close levels 1 and 3 and then anticlockwise to close levels 2 and 4 3 2 4 Drying in a closing device with heated shelves This combines the closing device with the heated shelves in one unit For use when extra heat is required in closable vials Operating Manual Freeze Drier Lablyo Plus and Accessories Page 16 3 2 5 Freeze drying with a column or lid manifold These manifolds use rubber valves to attach the glass freeze drying flasks The flasks are frozen first and then can be added
38. ve The sublimation curve shows the vapour pressure of water as affected by temperature and pressure Operating Manual Freeze Drier Lablyo Plus and Accessories Page 9 Phase diagram for solid liquid and vapour 1000 LIQUID 100 10 S 1 t E e 2 01 amp 001 VAPOUR 0 001 0 0001 0 00001 100 C 80 C 60 C 40 C 20 C 0 C 20 C 40 C 60 C 80 C 100 C oc 10 C Frozen in Time Ltd 20 C 30 C N Sublimation Curve 40 C 50 C 60 C g 0C 5 E E 80C He 90 C 100 C 865 4 3 2 1865 4 3 2 1865 4 3 2 1865 4 3 2 1865 4 3 2 1 10 0 1 0 0 1 0 01 0 001 Pressure mbar Operating Manual Freeze Drier Lablyo Plus and Accessories Page 10 2 2 Freezing Small product quantities can be frozen directly inside the ice condenser chamber of the Lablyo Plus Larger quantities are pre frozen in a deepfreeze This the usual option for product to be freeze dried in trays or vials Deep fill depths should be avoided by using wider containers filled to a shallower depth in order to maximize surface area Liquids to be dried in narrow ampoules should be frozen in a spin freezer this causes the product to freeze in a thin section up the wall of the tube Liquid to be dried in
39. y after every use Aluminium accessories are particularly prone to corrosion If there is the risk of toxic radioactive or pathogenic contamination special safety measures must be considered and adhered to 8 6 3 Maintenance of the air admittance drain valve Special attention must be paid to the air admittance drain valve If residues from previous drying processes deposit on it the freeze dryer may not achieve correct vacuum levels Therefore take care that no product or other residues will get into the valve 8 6 4 Disinfecting the drying chamber the lid and the accessories Check compatibility with the lid and the drying chamber The freeze dryers and the accessories are made of different materials A possible incompatibility must be considered For autoclaving the temperature stability of the individual materials must be taken into consideration Please consult us if in doubt If dangerous materials are used the freeze dryer and the accessories must be disinfected 8 7 Checks by the operator The operator has to ensure that the important parts of the freeze dryer that are necessary for Pane are not damaged This especially refers to Lid or drying chamber Seals Oil level of vacuum pump Accessories especially changes like corrosion wear and abrasion of material etc PAT test must be carried out annually Operating Manual Freeze Drier Lablyo Plus and Accessories Page 37 9 IQ OQ Qualification This Qualification P