Home
Loop-O9330 Fiber Optical Mux
Contents
1. a Tat 2 ETSI Unit Front View Features e 1U height full front access ETSI unit or front and back access ANSI unit e Rack mount wall mount and stand alone e WAN Ports e Two hot swappable optical cards One optical interface each card e Optical interface 1 1 protection switching max 50 ms e Tributary ports e IDM Interface e 4 slots each slot canbe 4E1 4 11 or 2 V 35 hot plugable card e Upto 16 E1 e Upto 16 711 e Upto 8 V 35 e Up to 4 10 100Mbps Ethernet bridge hot swappable card e Power Modules e Hot swappable DC plug in modules 48 Vdc 36 to 75 Vdc dual for redundancy e Hot swappable AC plug in module 100 to 240 Vac dual for redundancy Auto laser shutdown function is user configurable Loopbacks for optical link each E1 and T1 Office alarm contacts Firmware download to local unit and remote unit Management port and interface e Multicolor LED indicators e One LCD and keypad on ANSI panel optional e Console port VI 100 menu driven e SNMP port e Telnet via SNMP port e LoopView GUI EMS Loop 09330 Fiber Optical Mux Description Loop Telecom s Loop O Fiber Optical Mux product family provides ideal solutions for building fiber based E1 T1 networks As one of this family the Loop 09330 can transparently carry up to 16 channels E1 T1 or 8 channels V 35 DTE and 100 Mbps Ethernet signals over a single fiber All services are transported point to point in a real static TDM manner
2. Fax 1 561 627 6615 Fax 86 22 8789 0344 www LoopTelecom com michael_tzeng loop com tw jimber561 aol com wym loop t com sales loop com tw All Rights Reserved 2008 Loop Telecommunication International Inc Subject to change without notice Version 11 15 SEP 2008
3. 120Km LC optical connector Single mode mini GBIC SFP 155M 1310 nm commercial 0 to 70 C 30Km LC optical connector with digital diagnostic monitoring Single mode mini GBIC SFP 155M 1310 nm commercial 0 to 70 C 50Km LC optical connector with digital diagnostic monitoring Single mode mini GBIC SFP 155M 1550 nm commercial 0 to 70 C 100Km LC optical connector with digital diagnostic monitoring Single mode mini GBIC SFP 155M 1550 nm commercial 0 to 70 C 120Km LC optical connector with digital diagnostic monitoring E Where s1 s2 s3 s4 are used to select plug in modules for Slots 1 4 Note If none are needed skip 1 4 in the ordering code and proceed to s7 S EUR EUM EUD TUR VS Description Note Quad E1 unframed RJ48C Quad E1 unframed mini BNC Conversion cable is not included order conversion Quad E1 unframed DB25 cable separately from accessory Quad T1 unframed RJ48C Dual V 35 SCSI68 Conversion cable is not included order conversion cable separately from accessory E Where s7 is used to select a plug in module for Slot 7 Note If none is needed skip s7 in the ordering code and proceed to pp1 S BR Description Note Quad Ethernet with bridge 10 100m bridge E Where pp1 is used to select 1st power supply pp1 SA SD48 Single AC power supply 100 to 240 Vac Description Note For redundancy purposes ordering a second plug in module will provide dual pow
4. CC PC UK AC power cord for UK i Loop ACC PC AUS AC power cord for Australia Loop ACC PC CH AC power cord for China i Cable All Cables are RoHS compliant DB 25pin Male to BNC Male Extension Loop ACC CAB DB25M 100 8BNCM Cable Length 100 cm DB 25pin Male to BNC Male Extension Cable Length 300 cm SCSI 68pin Male to two M34 Male Extension Cable Length 100 cm Loop ACC CAB DB25M 300 8BNCM Loop ACC CAB SCSIM 100 2M34M Hot Pluggable Modules Loop 09330 S EUR G Quad E1 unframed RJ48C Loop 09330 S EUM G Quad E1 unframed mini BNC Conversion cable is not Loop 09330 S EUD G Quad E1 unframed DB25 EGS OAE Conve ONEADE separately from accessory Loop 09330 S TUR G Quad T1 unframed RJ48 Conversion cable is not Loop 09330 S VS G Dual V 35 SCSI68 included order conversion cable separately from accessory Loop 09330 S BR G Quad 10 100M Ethernet with bridge User s Manual Loop 09330 UM User s Manual optional paper copy A CD version of the manual is supplied as standard equipment E Where opti and opt 2 are used to select optical module types for Slots 5 and 6 Note If only one is needed skip opt2 in the ordering code and proceed to s opt Description Note SAA Single optical module with dual uni directional fiber 1310 nm SC optical connector 30 km reach 20dB SBB Single optical module with dual uni directional fiber 1310 nm SC optical connector 50 km reach 30dB Single optical module with dual uni directional f
5. E Std 802 1D MAC Bridging capabilities without spanning tree algorithm Automatic MAC table learning and aging Support VLAN and extended Ethernet frame support SNMP Port Protocol Telnet Connector RJ45 Console Electrical RS232 interface Protocol Menu driven VT 100 terminal Baud Rate 9600 19200 38400 57600 115200 bps asynchronous Connector DB9 female DCE Switches and Contacts Power Alarm Cut Off and ENTER for command execute Major and Minor alarm contact closures DB9F connector Diagnostics Test Optical Fiber Local and remote loopbacks E1 T1 Lines Local and remote loopbacks Power AC Power 100 240 Vac 50 60 Hz DC Power 48 Vdc 36 to 75 Vdc Power Consumption lt 20 Watts Physical and Environment Dimensions for 1U 432 x 44 x 226 mm W x Hx D Mounting Stand alone 19 or 23 inch rack mount wall mount Temperature Range 0 C to 55 C Humidity 5 90 RH non condensing Compliance EMI EMC EN50082 1 EN55022 EN55024 ITU G 703 G 706 G 732 G 823 Safety IEC60950 Application Illustration Tributary ports WAN ports Tributary ports Slot 1 4E1 4T1 or 2V 35 per slot 4F1 4T1 0r 2V 35 Optical Link per slot 4 10 100 BaseT 4 10 100 BaseT Ethernet Bridge Ethernet Bridge Protection Pair PORT4 PORTS PORT2 POR
6. TI 7 D oO D a cE wo CONSOLE NANI fo Ab of__e g oo oo o wo 4 3 2 1 E1 4 3 2 1 E1 50O of m O O O 100003 q O 00002 ACO PWR AC LINE 100 240VAC Oo OW o D 00001 50 60Hz 0 4A MAX TX RX 6 TX RX 5 4 3 2 1 El 4 3 2 1 E1 4 3 2 SNMP 09330 with AC Power D 48 V 0 5A QD PORT 4 PORT 3 PORT 2 PORT 4 7 4 2 nc EY NO CONSOLE 9600 n 8 1 rane i O Pole V 4V ar INK 10 00 LINK 10 100 LINK 10 100 UNK 10 100 ok 48 V 0 5A E 10100 __LINKJACT O O ACO PWR O O Q VW z SNMP 09330 with DC Power E P K P P ld P K Technologies 4 rue Edouard Branly Immeuble Hermes II 78190 TRAPPES FRANCE Tel 33 134 521 480 Fax 33 134 521 489 www pkt net com LOOP TELECOMMUNICATION INTERNATIONAL INC pusa Cee tae ae none ena Mm wav at 2 WD AvA VA LoopTelecom com ISO 900 1 150 14001 Worldwide Taipei Taiwan North America Tianjin China 8F No 8 Hsin Ann Road 6F No 36 Alley 38 Lane 358 8 Carrick Road No 240 Baidi Road Science Based Industrial Park Rueiguang Road Palm Beach Gardens Nankai District Hsinchu Taiwan 30078 Neihu Taiwan 11492 Florida 33418 U S A Tianjin 300192 China Tel 886 3 578 7696 Tel 886 2 2659 0399 Tel 1 561 627 7947 Tel 86 22 8789 4027 Fax 886 3 564 6272 Fax 886 2 2659 2325
7. er All plug in power modules are interchangeable If a unit is one day moved to a site witha Single 48 Vdc DC power supply 36 to 75 Vdc different power source the plug in module s can be changed For AC choose an appropriate power cord NOTE 1 E Where pp2 is used to select 2nd power supply pp2 Description Note SA Single AC power supply 100 to 240 Vac for ANSI only For AC choose an appropriate power cord SD48 Single 48 Vdc DC power supply 36 to 75 Vdc e NOTE 1 NOTE 1 The combinations of pp1 and pp2 power modules For ANSI unit pp1 SA Single AC power plug in in front or at rear pp1 SD48 Single DC power plug in at rear pp1 SD48 pp2 SD48 Dual hot swappable DC both rear plug in pp1 SA pp2 SA Dual hot swappable AC one front and one rear plug in pp1 SA pp2 SD48 Hot swappable AC front and DC rear plug in Note For ANSI unit DC power is available in rear panel only For ETSI unit all power modules in front pp1 SA Single AC power plug in pp1 SD48 Single DC power plug in pp1 SD48 pp2 SD48 Dual hot swappable DC power plug in E Where add is used to select LCD option add Description Note LCD LCD display LCD is supported for ANSI unit only Loop 09330 Fiber Optical Mux Product Specifications Optical Fiber Interface Source MLM Laser System Gain 30 dB Wavelength 1310 50 nm 1550 40 nm Line Code Scrambled NRZ Power 26 or 8 dBm Detector Type PIN FET Receiver Sen
8. iber 1310 nm an C optical connector 30 km reach 20dB o SDD Single optical module with dual uni directional fiber 1550 nm SC optical connector 20 km reach 12dB SEE Single optical module with dual uni directional fiber 1550 nm SC optical connector 100 km reach 40dB Single optical module with single bi directional fiber master e 1310 nm from master to slave SSM 1310 nm transmit and 1550 receive SC optical connector e Order SSM to use with SSS 30 km reach 20dB e Use 1 fiber Single optical module with single bi directional fiber slave e 1550 nm from slave to master SSS 1310 nm receive and 1550 transmit SC optical connector e Order SSS to use with SSM 30 km reach 20dB e Use 1 fiber SEPC SFP mini GBIC optical housing plug in card without SFP optical e Order SFP modules separately module from SFP table below SFP Optical Module Plug in Tables 155M bps MHBTW PHB3W PHBSW PHCUW PHCXW PHB3D PHB5D PHCUD PHCXD Multi mode mini GBIC SFP 155M 1310 nm commercial Use 2 fibers for all SFP 0 to 70 C 2Km LC optical connector optical modules Single mode mini GBIC SFP 155M 1310 nm commercial 0 to 70 C 30Km LC optical connector Single mode mini GBIC SFP 155M 1310 nm commercial 0 to 70 C 50Km LC optical connector Single mode mini GBIC SFP 155M 1550 nm commercial 0 to 70 C 100Km LC optical connector Single mode mini GBIC SFP 155M 1550 nm commercial 0 to 70 C
9. sitivity 38 dBm at BER lt 10 10 Fiber Type Single mode Optical Line Rate 155 52M bps Protection Optional 1 1 APS 50 Km reach Optical Fiber Interface Characteristics Optical Fiber Direction Wavelength nm Connector Distance km Power dB Module SAA Dual uni directional 1310 SC Subscriber Connector 30 20 SBB Dual uni directional 1310 SC Subscriber Connector 50 30 SCC Dual uni directional 1310 FC Fiber Connector 30 20 SDD Dual uni directional 1550 SC Subscriber Connector 20 12 SEE Dual uni directional 1550 SC Subscriber Connector 100 40 SSM Single bi directional master 1310 1550 SC Subscriber Connector 30 20 SSS Single bi directional slave 1550 1310 SC Subscriber Connector 30 20 E1 Line Interface Number of E1 lines Up to 16 Line Rate 2 048M bps 50 ppm Line Code HDB3 Line Impedance 120Q twisted pair 75Q for mini BNC Output Signal ITU G 703 Clock Transparent Connector 120Q RJ48C 75Q DB25 female future option 75Q MiniBNC T1 Line Interface Line Rate 1 544M bps 50 bps Line Code AMI or B8ZS Input Signal ABAM cable length up to 655 feet Output Signal DSX1 Clock Transparent Connector RJ48C V 35 Interface Data Port 2 ports per card DCE Data Rate n X 64K bps n 1 to 32 Clock Mode External Internal Received Selectable Connector SCSI 68 optional SCSI 68 Male to M34 Male DCE Conversion Cable Bridge 10 100M bps half full duplex Ethernet bridging and 100M bps operation on the HDLC port ANSI IEE
10. which includes a 16 E1 16 T1 or 8 V 35 b 100M bps Ethernet and c management channel The bandwidth is guaranteed for full configuration of the mentioned speeds for each channel service To select protection level users can choose either single pair or dual pair fiber Either a single power supply or dual power supplies can be chosen Loop 09330 offers management through console port Ethernet port Telnet and SNMP agents It supports local control and diagnostics using a 2 line by 16 character LCD display and keypads or console port The unit also supports local and remote monitoring and diagnostics Contacts for office alarms are available Applications for Loop O include interconnections for LAN WAN SONET SDH ATM and DLC Ordering Information To specify options choose from the list below Note RoHS compliant units are identified by the letter G appearing immediately at the end of the ordering code Model Description Note Main Unit Loop 09330 S CA opt1 opt2 s1 s2 1U height ANSI rear amp front access unit S3 S4 S7 pp1 pp2 add G Operating range 0 50C For allowed pp1 pp2 Loop 09330 S CE opt1 opt2 s1 s2 1U height ETSI unit fully front access combinations refer to NOTE 1 S3 S4 S7 pp1 pp2 G unit Operating range 0 50C Accessories Power Cord Order a power cord if you select the SA 100 to 240 Vac power option Loop ACC PC USA AC power cord for Taiwan America it Loop ACC PC EU AC power cord for Europe i Loop A