SmartLink-4 Software Installation & User Manual
Contents
1. Connection 3 Power Supply 12VDC 500mA Plug Pack 1 System Data Connection Green connector Plug cable connected to the SmartLink Receiver SCU via the DB25 connector on the Serial Extender Card Port 1 on the 4 Port Card Wiring instructions Connect Pin 1 Green socket connector to Pin 2 DB25 Connect Pin 2 Green socket connector to Pin 3 DB25 Connect Pin 3 Green socket connector to Pin 7 DB25 2 Telephone Line Connection Telephone line connection to existing telephone socket 3 3 Power Supply 12VDC 500mA Plug Pack Once the data and telephone connections have been made plug the 12VDC plug pack in to a power outlet The SmartLink Receiver SCU requires at least 12VDC Regulated 500mA power source to operate center pin ve 4 Hardwired Alarm Inputs 16 hardwired alarm inputs are supplied via a row of standard screw terminal connectors on the SmartLink Receiver SCU These alarm inputs are used to monitor external hardwired alarms such as BMS Security Fire Nurse Call and other miscellaneous hardwired alarm inputs e These 16 channels have fixed Client ID codes built in starting from 9901 to 9916 respectively e Client ID 9915 represents system AC Power Failure and Client ID 9916 represents system Low Battery used for monitoring Supply Power to system if required e An Alarm is generated when the input to the connector s common n and TB n is Closed e A Restore is generated when the
2. If this is a desired feature add a number between 1 and 30 to define the time period in days e g if a value of 20 is entered into Mrs Jone s Self Test value then Mrs Jone s SmartLink Medi Call unit has up to 20 days to dial in before a Self Test Failure alarm will occur notifying that the unit is not operating as correctly Note If a client is entered as ABSENT no Self Test will occur however all other alarms will operate as normal f PHONE Client s Telephone Number enter the Client s Telephone Number and press the Enter key g ROSTER For Automatic Paging the SmartLink 4 Software can handle up to 99 Rosters which are displayed in the Sub Menu These Roasters can be assigned to clients to define who should be paged Appropriate Roasters can depend on location to the client or by shift work etc For example when the alarm is activated for a certain client you may wish to have the closest person paged If Mrs Jone s room is in the North Wing then the designated person for the North Wing should be paged not someone in the South Wing For SmartLink 4 Software to determine who should be paged you will need to select a roster When an alarm goes off the SmartLink 4 Software will look up which roster the client has been assigned along with the time and whether it is a weekday or a weekend The software will then automatically page the appropriate person Refer to section 3 12 Rosters Setup To enter in a Roster press the Enter K
3. e Port Cable Combining 4 Ports to 1 Port 1 2 Tech Talk e 4 Port RS232 C Serial Card communication rates from 110 to 115 200 Baud e Remote Diagnostics via Dial Up Modem e POCSAG Output for On Site Paging e Dial Up PET Protocol for Wide Area Paging or access into host SmartLink Systems e Dial In Incoming PET Protocol allowing other Paging Systems to send messages via the SmartLink Software e Supports DEC VT100 and WYSE 30 terminal standards or a Windows terminal running VT100 Emulation 1 3 System Requirements e At least one spare ISA Slot on the PC motherboard for the 4 Port Serial Extender Card to function Computers that only have PCI and AGP slots on the motherboard will NOT be capable of running the 4 Port Serial Card e Ensure that IRQS is free and NOT used by another device eg Internal Modem Card Sound Card Network Card etc that may conflict with the Extender Card using IRQ5 e Do not change any settings on the 4 Port Serial Card default settings are correctly configured for SmartLink 4 1 4 BIOS Setup Peripherals Consult your computer manual for instructions on entering and modifying the computer s BIOS settings as follows e Onboard Serial Port 1 COM1 is set to 3F8h IRQ4 e Onboard Serial Port 2 COM2 is set to 2F8h IRQ3 e Onboard Parallel Port Printer Port is set to 378 IRQ7 e Parallel Port Mode is set to Normal or SPP Standard 1 5 Installation Procedure 1 Turn the Computer off and rem
4. a site survey you should pay particular attention to the quality of the messages that you receive on the test pager If you receive corrupted messages then it is possible that you will have problems sending messages to that particular region The Survey Site screen is a useful tool for testing coverage of your transmitter All you do is send out a test message periodically and then walk around looking for trouble spots Note Pressing the F1 key will bring up the Online Help Tutorial that will provide addition information on this topic e Select Survey Pager Group e ACTIVATE DE ACTIVATE Site Survey e Specify Time Interval e ADTIVATE DE ACTIVATE Test Mode e Exit Site Survey 1 From the Main Screen go to Maintenance then System Configuration then Survey and press the Enter key You will now be presented with Survey Site screen 2 Press the Enter key and you will be presented with a list of pager names 3 Use the Up and Down Arrowkeys to highlight the pager that you wish to send test messages to and press the Enter key 4 Specify the Timer Interval set to a default of 60 seconds 5 Use the Up and Down Arrow keys to highlight ACTIVATE Site Survey and press the Enter key to begin surveying 6 When finished testing press Enterkey again to DE ACTIVATE Site Survey 7 Highlight Exit Site Survey and press the Enter key then highlight Exit and press the Enter key again to return to the Main Menu 4 9 Reviewing the System Status This facil
5. elsewhere on the system will be automatically reflected in the graphical representation of the top callers Gf applicable As the number of calls per person increases the horizontal axis representing the number of calls made will automatically adjust to suit the largest number of calls made Call Statistics Call Rate Statistics This is by far one of the most important facilities provided by the SmartLink 4 package with respect to administration This facility allows you to review the call rates on a per day basis within a year with a further break down of the calls made for a particular day on an hourly basis This facility allows you as an administrator to analyze call trends over days weeks months and even a complete year You also have the ability to view at a glance the average number of calls for the year as well as on an hourly basis This will allow you to adjust staffing levels according to peak and low periods on a per day basis based on the daily average or alternatively on a weekly basis for holiday periods Further to this you can also cross tabulate any particular period with the actual calls being sent out via the paging system using the Report Wizard Report Wizard Generating Your Own Reports By far the most important aspect of the system is the ability to produce a report on any aspect of the system This facility is known as the Report Wizard This allows you to produce your own custom designed reports from the history
6. input to the connector s common n and TB n is Opened Where n represents the channel number 1 to 16 5 Relay Output C NO NC The single Relay Output is used to provide an external output for interfacing third party systems The Relay Output is controlled by the computer which incorporates a communications Watchdog system The relay is in the normally closed position when communication is established with the computer and will change state when communication is lost Note SmartLink Software also has an extra Watchdog circuit facility incorporated where if communication is lost to the SmartLink Receiver SCU the SmartLink Software will automatically page the service pager of the fault 2 4 LED Status LED Number LED Colors LED Status 1 Red NA NA 2 Red NA NA 3 O Red Fast Flashing PC Communication Note Both LED 3 and 4 4 O Red Fast Flashing PC Communication rapidly fl sh when 5 O Red Slow Flashing Modem On pray SAO 6 D Yellow ON Incoming Alarm communication is established 7 8 Yellow NA NA 8 O Green ON Communication Failure 9 O Green NA NA 2 5 Additional Notes e When making or changing connections to SmartLink Receiver SCU check that the SmartLink Receiver SCU is OFF by disconnecting the plug pack from the power outlet e Do not change any settings on the SmartLink Receiver SCU This has already been configured and defaulted by the SmartLink Engineers e For Smar
7. test call Cancel button pressed without a previous alarm 55555555 9 Send an auto test call 15555555 6 A power failure has occurred 35355555 6 Power is restored 51555555 6 Battery is low and approaching its cut off threshold point 11555555 6 Power fail amp low battery Battery may need replacing 15555555 7 Person attending a previous alarm on zone 1 needs urgent assistance 85555555 7 Alarm on zone 1 and pendant transmitter has a low battery 15555555 1 Duress Emergency panic 35555555 1 Duress is restored 55555555 2 System switched off opening 15555555 3 Zone 1 has been isolated or bypassed 55555555 4 System switched on closing 15555555 5 Trouble alarm on zone 1 Low battery on device Note The above examples use a test client code 1111 SMART gt LINK Tomorrows Technology Today Copyright SmartLink International Pty Ltd August 2001 Email smartlink smartlink com au Web Site www smartlink com au To the best of our knowledge the information contained in this manual is correct at the time of print SmartLink International Pty Ltd reserve the right to make changes to the features and specifications at any time without prior notice in the course of product development 19
8. with a list of Client Names and ID Codes Use the UP and Down Arrow keys to highlight the Client that you wish to Remove Delete and press the Enter key You will now be asked if you are sure Choose OK and press the Enter key to Remove Delete that client from the list Viewing Responses This function allows you to review whether a Client s Med Call Unit has called in to the SmartLink 4 Monitoring Software during the designated time span To view this function highlight View Responses from the High Level Interfaces menu then press the Enter key Press the Enter key again to view a list of the Client Names and ID Codes that have not called in You can then select a client by using the Up and Down Arrow keys and press the Enter key to bring up the Clients Details if you wish to take further action Otherwise you can ring any relevant Contacts or Clients displayed on the right hand side of the screen Press the ESC key to return to the High Level Interfaces menu Setting up ADEMCO The Setup Ademco function allows you to change the alarm names and system names that appear in the SmartLink 4 Software This means you can change the descriptions to suite your own company s needs and preferences The alarm name indicates the status of the alarm zone whether everything is normal or if the alarm is activating The system name indicates the type of alarm whether it is for zone trouble duress etc By changing the names of the alarms and systems in the Set
9. CC Configuration 1 From the Main Screen go to Maintenance then System Configuration then Port and press the Enter key 2 You will now be presented with the relevant Port Configuration Screen Select any available port normally Wide Area Paging is set to Port 3 and press the Enter key twice Ensure that the modem is connected to the appropriate port e g port 3 of the 4 Port Serial Card and that the power is on 3 You will then be provided with a field listing a variety of Configurations Use the Up and Down arrow keys to highlight TAP OUT DIAL UP and press the Enter key 4 Type in a name for the new interface e g WIDE AREA PAGING 5 Use the Up and Down arrow keys to change the baud rate Modems are normally set at Baud Rate of 1200 with Data 8 Stop Bits 1 and Parity None 6 Set the Protocol to PET 1 Message Length to 100 and Messages to 10 7 Press the F10 key to save settings and press ESC Key twice to return to the Main Screen 8 Main Screen Go to Maintenance System Configuration RCC and press the Enter Key 9 With RCC 1 highlighted press the Enter key and enter the data provided by your RCC into the appropriate field Repeat this process if you have more then one RCC SmartLink 4 can handle up to 32 RCCs by selecting the next available RCC 10 Press the F10 key to save these settings and press the ESC key twice to complete the installation of the Wide Area Paging and return to the Main Screen Note To A
10. Export Call Data Export Client Call Data e Exit Exit the Backup Restore Facility and return to the Main Menu screen 4 12 Entering Test Data Strings 1 Hold down the Control key and press the Print Screen key 2 Enter the data defining the type of alarm followed by the Enter key An appropriate data string contains a 4 digit client code followed by 8 digits of channel data or zones and a type identifier as follows client code channel data type identifier For example 1111551555557 Where 1111 is the client code 55155555 is the channel data and 7 is the type identifier Pressing the S key when an alarm is visible on the screen will bring up additional notes and statistics associated with that particular alarm If an alarm is already on the screen and a new alarm is generated the screen will display new alarm s pending and identifies the first alarm by name and the total number of other alarms pending in queue 18 The following examples display typical communications between a SmartLink and its monitoring terminal and radio pagers as listed below a b c d e f g h 1 j k 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 1111 15555555 7 Send an alarm on zone 1 35355555 7 Send a restoral or cancel the zone alarm 51555555 7 Send an alarm on zone 2 53555555 7 Send a restoral or cancel the zone 2 alarm 55555555 7 Send a manual
11. SMART lt LINK Tomorrows Technology Today SMARTLINK 4 MONITORING SOFTWARE INSTALLATION amp USER MANUAL CONTENTS Is Is I gt LE PO A it 2 12 Teh la ie 2 LAS OSO AA AI 2 LA BIOS Seup Penphem Sl uuu uuu u ako eae ee a qysaas s 2 LS moelion Procede tata 2 RECEIVER SCU INSTALLA TION 3 PA O ISU di 3 2 Toh AA E EAEE E EE 3 23 System COMO ii iria 3 2a LED SSD u uuu mau mana iya i n 4 PA ANO E ad 4 SOFTWARE INSTALLATION amp SETUEP 5 Ji A a ia 5 3 2 DOWA A ULU a ar REE E EE A EEE R E E REARS 5 A LA E e E 5 34A Installation PRI AS 5 23 Running IS a 6 20 TUI LEl A Ra 6 3 7 SmatLink Receiver SCU A a bas 6 2S TS PARO SSE is 7 29 Wide Neea Parme a A A in 7 3 10 ChHe nts O asa 8 311 Paget tor Mobile Phone Details ASMA uso 11 e IN i 11 2 13 Group Details ia 12 SOFTWARE USER MANUAL msn 13 A A A e UE EE EE E E RREA 13 da Runnine the ANO do 13 4 3 Exiting the SOT os dns 13 E Ock Reference id 14 45 Reviewing Active AO sar 15 3 6 Status iia 15 d Mamia O A AA A 15 EN O S u cates E ease q eee eee hass asayayyas 16 49 Reviewimgihe System NN ti 16 4 10 Using the Report IIA A 17 4 11 Using File Mana ae 18 4 12 Entering Test Data A iieo oninia ereenn a a saaa i Es 18 1 4 PORT SERIAL CARD INSTALLATION 1 1 Equipment List e 4 Port Serial Extender Card
12. ach alarm input will display information about the alarm such as its name how long it has been activated for whether or not it is urgent and who is currently being contacted Note Pressing the F1 key will bring up the Online Help Tutorial that will provide addition information on this topic 1 From the Main Screen go to Display then Active Alarms and press the Enter key 2 You will now be presented with the Reviewing Active Alarms screen Use the Up and Down Arrowkeys to find an active alarm and press the Enter key or the Page Up and Page Down keys to select the relevant Alarm Screen 3 Press the ESC key twice to exit to the Main Screen 4 6 Status Symbols There are 4 symbols in the top right hand corner of the SmartLink 4 Main Screen that provide real time updates on message activity The three left most dots indicate the progress of TNPP Wide Area and Local Area On Site messages respectively The dots are Red if there are messages waiting to be sent otherwise they are Green The last icon is a musical symbol that represents the status of the Local Area On Site Transmitter A single Red flash of the musical symbol indicates that the Transmitter is sending a message a Green musical symbol indicates that the Transmitter is idle and a permanent Red musical symbol means that it cannot transmit due to interference 4 7 Manual Paging The simplest way of sending messages in SmartLink 4 is to use a Manual Page Simply select th
13. at will provide addition information on the topic of Installing Modifying Pager Details 3 12 Rosters Setup Note Pager or Mobile Phone Details must be entered in first before Rosters can be Setup Refer to Section 3 11 Pager or Mobile Phone Details Setup For Automatic Paging the Roster must also be enabled selected in the Clients Setup Refer to Section 3 10 Clients Setup Adding a Client Automatic Paging 1 From the Main Screen go to Maintenance then Alarm Configuration then Rosters and press the Enterkey 2 You will now be presented with the Alarm Roster Schedule Configuration screen with ROSTER 1 highlighted 3 Press the Enter key or use the Up and Down Arrow keys to select a ROSTER between 1 and 99 Note that the Roster names can be changed or left as default e g ROSTER 1 11 4 5 6 Use the Up and Down Arrow keys to highlight Weekday Operation Enter in a time based on a 24 hour clock 1 e 00 01 to 23 59 and press the Enter key You will now be presented with a Sub Menu Use the Up and Down Arrow keys to select pager mobile phone for Automatic Paging and press the Enter key Note that you can use up to four roster shifts to select whom you wish to receive alarm call messages at different times of the day Press the F8 key to toggle Weekend Operation and repeat the same precudure in the previous step Press the F10 key to save and press the ESC key twice to complete setting up the Rosters and exit t
14. cted and the power is on failing to connect the Antenna while transmitting can damage the Transmitter 3 You will then be provided with a field listing a variety of Configurations Use the Up and Down arrow keys to highlight POCSAG OUTPUT and press the Enter key 4 Type in a name for the new interface e g LOCAL TRANSMITTER 5 Ensure the configuration is set to EXCLUSIVE for a single local transmitter select NON EXCLUSIVE if the Smartlink 4 system is intended to control multiple Transmitters and there is the possibility that they may transmit simultaneously 6 Press the F10 key to save settings and press the ESC key twice to complete the On Site Paging installation and return to the Main Screen Note To Add Modify Pager Details refer to Section 3 11 Pager or Mobile Phone Details Setup Transmitter Types Setup Go to Maintenance then System Configuration then System and press the Enter key for a e 2 Watt Transmitter select Invert using the Space Bar key e 4 Watt Transmitter select Normal using the Space Bar key e 5 Watt Transmitter select Normal using the Space Bar key 3 9 Wide Area Paging Setup To setup a Wide Area Paging service you will require a variety of information such as Phone Number Password and Serial Data Format baud rate data bits stop start bits amp parity This information should be provided by your RCC Radio Common Carrier For more information press the F1 Key online Help Tutorial and choose Topic R
15. dd Modify Pager or Mobile Phone Details refer to Section 3 11 Pager or Mobile Phone Details Setup 3 10 Clients Setup Adding a Client 1 From the Main Screen go to Maintenance then Alarm Configuration then High Level and press the Enter key alternatively from the Main Screen go to Maintenance then Interfaces and press the Enter key 2 You will now be presented with the High Level Interfaces menu Choose the port associated with the SmartLink SCU normally Port 1 of the 4 Port Serial Card and then press the Enter key 3 Use the Up and Down Arrowkeys to select Add New Client and press the Enter key 4 You will now be presented with the View Client Details screen Note Additional information eg Medical history ect may be added to a client s records later by viewing full client alarm details and pressing the S key See Listing Clients for more details a CLIENT Client s Name enter in the brackets and press the Enter key b CODE Client ID Code allows you to enter in a Four Digit ID Code that has been assigned to the Client SmartLink unit If you enter in an ID Code that is already in use you will be presented with a screen telling you that another client is presently using the user ID You will then be given an option to either overwrite the client s record or view the client s record that is using that ID If you want to do neither choose Cancel If you choose to view the client s record then y
16. e and time an alarm has occurred e A multitude of High Level Interfaces is available including Fire Security Nursecall Duress Poker Machines and Care Packages 3 3 System Requirements e Minimum Pentium 120MHZ CPU with 32MB of RAM and 250MB of hard disk space e Capable of running MS DOS or Windows MS DOS Mode i e shut down Windows and restart in MS DOS Mode NOT a MS DOS Prompt running within Windows e At least one spare ISA Slot on the motherboard for the 4 Port Serial Card Computers that only have PCI and AGP slots on the motherboard will NOT be compatible with the 4 Port Serial Card e Ensure that IRQ5 is free and NOT used by another device eg Internal Modem Card Sound Card Network Card or any other cards that may interfere with the Serial Extender Card which uses IRQ5 e SmartLink 4 Software relies on serial communications Ensure that both primary serial ports COM1 and COM2 are available Note that USB Ports are NOT compatible with the SmartLink 4 Monitoring Software 3 4 Installation Procedure 1 Insert the SmartLink 4 Software Floppy Disk into the Floppy Disk Drive 2 Type a install followed by the Enter key 3 Follow the instructions on the screen a SmartLink v4 13 Installation press the Enter key to continue b SmartLink Registration Requesting you to type in Owner s Name Company Name and Address Press the F10 Key to continue c SmartLink Power Up Press the Y key for Yes followed by the F10 k
17. e people you wish to contact type in the message and then send the message SmartLink 4 takes care of the rest Manual Keyboard paging allows you to effectively contact key personnel quickly and efficiently You have the ability to contact any number of personnel simultaneously by simply selecting them from an alphabetically sorted list of pagers mobile phones and group names 1 From the Main Screen Go to Manual Page and press the Enter key You will now be presented with the Manual Page screen 2 Press either the TAB key or Enter key and you will be presented with a list of pager names 3 Use the Up and Down Arrowkeys to highlight the pager that you wish to page and press the Enter key 4 Type in the Alphanumeric message you wish to send to the Alphanumeric Pagers Mobile Phones or the Numeric message you wish to send to specific Numeric Pagers 5 Press the F10 key to send the message 6 Press the ESC key to exit and return to Main Screen Note Pressing the F1 key will bring up the Online Help Tutorial that will provide addition information on this topic 15 4 8 Surveying Sites It is a good idea to test the coverage of your local area Transmitter If you use The Survey Site screen to send periodic test messages then you can roam around the installation site with a test pager Thick steel and concrete large magnetic and electric fields and terrain and weather conditions will affect Transmitter efficiency When you perform
18. equire message stamps and Require automatic logging options should be activated Use the Left and Right Arrow keys to change these options between YES activated and NO deactivated 8 Press the F10 key to save settings and then press the ESC key to return to the Main Screen to complete setting up the Pager or Mobile Phone Details Modifying Pager or Mobile Phone Details Press the TAB key in the Pager Name field to display the list of pagers installed in the SmartLink 4 database If no list appears then no pagers are setup in your database Use the Up and Down Arrow keys to highlight the pager you wish to modify then press the Enter key The Pager Details screen will update to reflect the change If you make any changes press the F10 key to save followed by the ESC key to exit to the Main Screen Removing Pager or Mobile Phone Details Use the Up and Down Arrow keys to highlight the pager you wish to remove and press the Enter key to select Alternatively press the Insert key to tick off a number of pagers that you wish to delete and then press the F10 key when you have completed your selection SmartLink 4 will prompt you for confirmation before deleting any pagers in the database Select OK and press the Enter key to proceed or choose CANCEL if you don t want to remove the pagers Press the ESC key to return to the Main Screen Note Pressing the FI key while viewing the pager details setup will bring up the Online Help Tutorial th
19. esting you for the Maintenance Password to exit SmartLink 4 Software 2 Type in MAINTENANCE or POWER and press the Enter key The SmartLink 4 Software will prompt you for confirmation before exiting Select OK and press the Enter key to proceed or CANCEL if you don t want to exit alternatively press the ESC key to return to the Main Screen 13 4 4 Quick Reference Keys Help Tutorial F1 Online help is provided in two forms 1 From the Main Menu press the Fl key to bring up the Context Sensitive Online Help Reference screen Use the Up and Down Arrow keys to Scroll through the current topic and use the Left and Right Arrow keys followed by the Enter key to select Next or Previous to browse through topics one at a time Topics to provide a full listing or Exit to Main Screen 2 From the Current Screen press the F1 key to display a brief description of the current window menu option or entry field Enable Screen Saver F3 Press the F3 key to leave a Screen Saver indicating whether the SmartLink 4 software is currently in Staffed or Away mode of operation Change Level of Access Operator Administration Maintenance F5 SmartLink 4 operations are divided into three distinct levels of accessibility Each level provides additional features and operations Users can change between Access Levels with the higher access levels providing more complicated facilities 1 From the Main Screen press the F5 Key to display the l
20. ey again to show the Sub Menu Choose the relevant Roster by using the Up and Down Arrow keys for that client and press the Enter key Note Always choose or enter a Roster e g ROSTER 1 even if no Rosters are required h CONTACT Client s Contacts allows you to enter details of the client s contacts in case of an emergency such as next of kin Enter in the first contact s name in the first bracket and press the Enter key followed by Phone bracket and Relationship bracket a list of options for Relationship can be brought up by pressing the Enter key Repeat this process for all appropriate Contacts If you only wish to enter one contact repeatedly press the Down Arrow key instead of the Enter key until you have reached the first ALARMS bracket i ALARMS Alarm Descriptions allows you to enter your own descriptions for 8 different alarms referred to as zones These could be panic button inactivity smoke detector bedroom call point etc In the event that an alarm is activated the SmartLink 4 Software Setup will show exactly which zone has set off the alarm and what type of alarm it is If zone 1 is breached next to that bracket a FLASHING bar will come up describing the urgency severity of the alarm i e whether it is an Emergency or the alarm has a Low Battery etc At the top of the screen next to EVENT it will show what type of alarm it is i e if it is a duress call zone trouble etc To enter in a description of an a
21. ey to continue if you would like SmartLink 4 to load automatically on boot up of the PC To install without this feature choose N for No d Once the SmartLink 4 Software installation is complete takes approximately two minutes press the Enter key to continue before removing the SmartLink 4 Software Disk 4 Connect the Dongle on the Printer Parallel Port of your computer then re boot to start the Smartlink 4 Monitoring Software for the first time 3 5 Running the Software Note Ifat the time of installation you chose to have the Smartlink 4 automatically load on boot up please ignore this section For manually loading Smartlink 4 from MS DOS do the following e Type CASMARTLNKISMARTENKispaco SAVER Note SMARTLINK without the letter D at the MS DOS prompt followed by the Enter key 3 6 User Access Level In order to setup SmartLink 4 you must be in Maintenance Access Level 1 Press the F5 key from the Main Screen while no other screens are displayed You will be presented with the Select Level of User Operation dialog box 2 Use the Up and Down Arrow keys to highlight Maintenance Access and press the Enter key 3 SmartLink 4 will now requesting you for the Password Authorization Type in POWER or MAINTENANCE and press the Enter key to gain Maintenance Access Level privileges 3 7 SmartLink Receiver SCU Setup 1 From the Main Screen go to Maintenance then System Configuration then Port and press the Enter key 2 You
22. ity provides you with important summary information concerning the status of your system such as Installation details Hardware details Alarm details and Call details etc All of these details are updated in REAL TIME to give a true indication of what is occurring Note Pressing the F1 key will bring up the Online Help Tutorial that will provide addition information on this topic e Build Version Info e Transmitter Summary e Pager Group Summary e Call Summary e Hardware Summary e Network Summary e Port Summary e Exit e PBX Summary 1 From the Main Screen go to Display then System Status and press the Enter Key You will now be presented with the System Status screen 2 Use the Up and Down Arrow keys to highlight the topic you wish to summarize and use the Page Up or Page Down keys to summarize the relevant page 3 Highlight Exit and press the Enteror ESC key return to Main Screen when complete 16 4 10 Using the Report Summary Graph Top Callers Graphing The Top Callers This displays the fifteen most frequently paged people and the fifteen top people who have not responded to alarm activation within the designated time period The graphical representation of the top callers takes place in a horizontal graph where the most frequently called person is displayed at the top and the fifteenth most frequently called person is displayed at the bottom of the graph This facility updates in real time so that any calls being made
23. larm type in the description in the first bracket and press the Enter key Repeat this process for all required zones to enter their individual descriptions 5 Press the F10 key to save then choose OK and press the Enter key to conclude the entering of the Client s Details Listing Clients Highlight List Clients from the High Level Interface menu and press the Enter key You will be presented with a list of Client Names and ID Codes You can scroll through this list by using the Up and Down Arrow keys and using the Enter key to select Press the ESC key to exit this function When viewing a client either in the Client List or under Display Active Alarms press the S key to bring up the Review Client Statistics window This can now be used to store additional notes and provide further statistical information if required NB Press the F10 key to save entered information Editing Clients Highlight Edit Clients in the High Level Interface menu and press the Enter key You will be presented with a list of Client Names and ID Codes Using the UP and Down Arrow keys to highlight the Client that you wish to Edit Modify and press the Enter key to select Edit the appropriate fields as described in Adding a New Client Press the F10 key to save choose OK and press the Enterkey to finish modifying editing a Client s Details Removing Clients Highlight Remove Clients in the High Level Interface and press the Hnter key You will be presented
24. o the Main Screen Note Pressing the FI key while viewing the pager details setup will bring up the Online Help Tutorial that will provide addition information on the topic of Defining Roster Schedules 3 13 Group Details Setup Note Pager or Mobile Phone Details must be entered in first before Rosters can be Setup Refer to Section 3 11 Pager or Mobile Phone Details Setup 1 2 3 4 5 6 7 8 From the Main Screen go to Modify then Group Details and press the Enterkey You will now be presented with the Group Details screen with your cursor highlighting the Enter Group Name option Type in a Group Name e g North Wing Group and press the Enter key Enter a PBX Number used for PABX Communications and default to the next available number The Rotary Group Calling is used to distribute workload among staff and is set to NO as default The Require Time and Date Stamp can be changed using the Left and Right Arrow keys and is set to No as default The Require Automatic Logging is used to generate reports at a later point in time and is set to Yes as default Press the F10 key to save and press the ESC key to complete the Group Details Setup and return to the Main Screen Note Pressing the FI key while viewing the pager details setup will bring up the Online Help Tutorial that will provide addition information on the topic of Installing Modifying Group Details 12 4 SOFTWARE USER MANUAL 4 1 Introd
25. of the calls made on the system e g a report could be generated for all calls sent to Joseph Banks between a certain time and date generated by the Pressure Valve 10 alarm being activated This is by far the most powerful report generator available for any paging product to date Normally you would have to generate the report yourself by exhaustively searching through the stored logs This not only consumes large amounts of human resources but also the Paging System would be unavailable for this time With SmartLink you can simply specify the report that you want to generate and the Report Wizard will search the stored logs and produce the report either to be displayed on the screen printed or saved for later retrieval and at the same time not sacrificing any of your time or the system s time Viewing Reports Viewing a Previously Saved Report As described earlier you have the ability to generate your own custom made reports around any aspect of the system based on the stored logs As an administrator you may wish to save these newly generated reports for future reference If so by using this facility you have the ability to load and view these reports at any time in the future and if necessary print them out 17 Print Reports Printing Reports A very important part for any Paging System is the ability to print out reports on various aspects of the system for future reference SmartLink 4 allows you to print out various standard
26. ogon Screen 2 Use the Up and Down Arrowkeys to Select level of User Operation Operator Allows manual paging messaging status of alarms and some statistical analysis No password is required Administration Access to Maintenance Databases to edit Clients Rosters for keeping backups and monitoring System Reports The default Password is Administration Maintenance for installation and setup of SmartLink 4 Hardware and other restricted Database features and configurations The default Password is Maintenance 3 To return to the most restricted level of access press the F5 key select Operator Access and press the Enter key note that no password is required for this Toggle Staffed or Away F6 Toggling the F6 key will switch SmartLink 4 between STAFFED and AWAY modes STAFFED Monitoring Centre must process incoming alarms by pressing the Enter key Computer speaker beeps are enabled AWAY alarms are automatically process and computer speaker beeps are disabled Display Last Alarm F8 Press the F8 key to display the last incoming alarm Display Version Information Shift TAB The Version Information or About screen displays the SmartLink 4 Version Number Copyright and Memory Available etc and can be viewed by holding down the Shift ke y and pressing the TAB key at the same time 14 4 5 Reviewing Active Alarms This facility allows you to view all the currently active alarm inputs on the system E
27. ou will be presented with the client s details which you can modify if you choose If you do not wish to modify these details press the F10 key or the Esc key to go back to the SmartLink High Level Interfaces menu If you need to use an ID Code that is already in use contact the System Administration Note If you choose to overwrite the client s record all of the client s details will be lost c STATUS Client s Status press the Enter key to show a Sub Menu of ABSENT or PRESENT This function allows you to keep track of field units Self Test facilities If a unit is present yet there has been no test report detected by the SmartLink 4 Software for a programmed period of time 1 to 30 Days then the SmartLink 4 Software will automatically generate a Self Test alarm and notify the relevant personnel Choose either PRESENT enable test reports or ABSENT Disable test reports using the Up and Down Arrowkeys followed by the Enter key to select your choice d ADDRESS Client s Address There are three lines that can be used for the Clients Address Your cursor will start the first line of the address bracket and as you enter data followed by the Enter key the curser will automatically go to the next line e SELF TEST Self Test Function prevents the scenario of a field unit malfunction going unnoticed The Self Test function means that a clients alarm must call the SmartLink 4 Software periodically to demonstrate that it is still working
28. ove the cover side panel of the computer case 2 If you have a static strap then you should put it on Static electricity may damage sensitive computer components 3 Insert the 4 Port Serial Card into a spare ISA Slot in the PCs motherboard Make sure that all pins of the Serial Extender Card are firmly inserted in the ISA Slot A partial connection may damage the Serial Extender Card 4 Screw the Card to the computer case to fix it in place and replace the cover on the Computer and turn it on 5 Ensure the System Requirements and BIOS settings are configured appropriately to conclude the installation of the 4 port Serial Card 2 RECEIVER SCU INSTALLATION 2 1 Equipment List e SmartLink Receiver SCU e Telephone Line Cord e 12VDC 500mA Regulated Plug Pack e Cable Green connector plug to 25 pin female D Connector 2 2 Tech Talk e Monitors Ademco High Speed Expanded and Contact ID e Stores and Buffs up to 500 events e On board RS232 485 Port for PC Connection e In built automatic Watchdog circuit e Single Relay Output C NO NC which activates on communication failure to the PC e 16 Hardwired Alarm Inputs 15 amp 16 reserved for external AC Fail amp Low Battery 2 3 System Components The illustration below indicates the relevant connections for the SmartLink Receiver SCU 4 Hardwired 1 System Data Alarm Inputs Connection installation 5 Relay Output 2 Telephone Line C NO NC
29. reports to assist you with administration and maintenance These reports provide an invaluable hard copy of your system details and more importantly the SmartLink 4 Software reporting capabilities can also allow for these reports to be even further refined This will give you the ability to print out specific parts of a report and set how many copies that you wish to print 4 11 Using File Management From time to time the system administrator may require maintenance in the form of backing up to restore the system database as well as clearing the transaction log This is a very simple task and requires very little time and user interaction It provides security for your system in the event of computer failure as well as the ability to back up the history of your system for administration purposes Such a task may be performed on a weekly monthly or yearly basis Note Pressing the F1 key will bring up the Online Help Tutorial that will provide addition information on this topic 1 From the Main Screen go to Maintenance then File Management and press the Enter key You will now be presented with the SmartLink File Management screen 2 Use the Up and Down Arrowkeys to highlight the desired topic and press the Enterkey e Backup Backup System Files to Floppy Disk or Hard Disk e Restore Restore System Files from Floppy Disk or Hard Disk e Clear Log Clear the existing Transaction Log e Clear System Clear the System Transaction Log e
30. tLink 4 Software DIP switch SW1 inside the SCU should have switches 1 5 ON and all other switches OFF The four jumpers LK7 LK8 LK5 LK6 near the System Data Connector 3 wire green terminal socket should be set to RS232 Mode e For SmartLink NT Software DIP switch SW1 inside the SCU should have switch 5 ON and all other switches OFF The four jumpers LK7 LK8 LK5 LK6 near the System Data Connector 3 wire green terminal socket should be set to RS232 Mode If more than 1 SmartLink Receiver SCU is used up to 16 maximum an RS232 to RS485 converter is required product number RS232 4 3 SOFTWARE INSTALLATION amp SETUP 3 1 Equipment List e SmartLink 4 Software Installation Disk gt r m e Installation amp User Manual iii e Dongle me e 4 Port Serial Card 3 2 Software Overview The SmartLink 4 Monitoring Software represents the most advanced computer based on site and remote monitoring paging platforms available in the world today e Monitors ADEMCO High Speed Expanded and Contact ID formats e Automatic reporting and notification of a failure of Exception Reports e On Site POCSAG and Wide Area PET TAP Paging e Dynamic pager and group management automatic workload management for groups e Reminder Messages and Booked Calls e Automatic System Failure Communication Watchdog Paging e Rostering system allowing the SmartLink 4 Software to contact various staff groups depending on the sourc
31. uction The SmartLink 4 Monitoring Software is designed to notify people when an alarm is activated glve details of that alarm and whom to contact refer to Section 3 10 Clients Setup Adding a Client To use these functions you will need to enter client and alarm details into the programs client database Details you will need to provide are e Client Name e Client Code a four digit ID code for Client reference e Whether the client is absent or present for auto test reports e Client Address e Self Test Default 7 Days e Client Telephone Number e Roster e Contact Whom to Contact in case of an alarm e Alarms 8 different alarm zone descriptions A message is sent to the SmartLink 4 Software from the SCU receiver for the following e Client Alarms e Opening Reports e Closing Reports e Zone Exclusions e Zone Trouble e System Alarms e Self Tests failure to test 4 2 Running the Software Note If at the time of installation you chose to have the Smartlink 4 Software automatically load on boot up please ignore this section For manually loading Smartlink 4 from MD DOS do the following e Type C SMARTLNK SMARTLNK space SAVER Note SMARTLINK without the letter D at the MS DOS prompt followed by the Enter key 4 3 Exiting the Software To quit and exit to MS DOS simply 1 Press the ESC key from the Main Screen while no other screens are displayed You will be presented with the Password Authorization dialog box requ
32. up Ademco option you are making a global change throughout the SmartLink 4 Software For example if you were to change the System name Duress to read Code Red every time a duress occurs SmartLink 4 Software will display Code Red not Duress Highlight Setup Ademco from the menu and press the Enter key Use the Up and Down Arrow keys to highlight the alarm or system name you wish to change and system names and press the F10 key to return to the High Level Interfaces menu WARNING This should only be used when customising of alarm types is required The default alarm names are based on a standard that will suit the majority of installations 10 3 11 Pager or Mobile Phone Details Setup 1 From the Main Screen go to Modify then Pager Details and press the Enter key 2 Enter a name for the pager eg ADMINISTRATION 1 and press the Enter key 3 Enter the Pager Capcode e g 1234567 Normally this is the last 7 Digits of the Pager or Mobile Phone Number 4 Enter the PBX Number used for PABX Communications and default the next available number 5 Use the Up and Down Arrowkeys to select the Pager Type then press the Enter key Use the Up and Down Arrow keys to select TONE ONLY PAGER NUMERIC PAGER or ALPHANUMERIC PAGER 6 Press the Enter key twice and select the Network Type Use the Up and Down Arrow keys to select TRANSMITER or WIDE AREA PAGING and press the Enter key 7 For most situations the Require time and date stamps R
33. will now be presented with the relevant Port Configuration Screen Select any available port normally SCU is set to Port 1 and press the Enter key twice Make sure that the Receiver SCU is connected to the appropriate port e g port 1 and that the power is on 3 You will then be provided with a field listing a variety of Configurations Use the Up and Down arrow keys to highlight SMARTLINK and press the Enter key 4 Type in a name for the new interface e g SMARTLINK SCU 5 Use the Up and Down Arrowkeys to highlight the Baud Rate option and press the Enter key Then use the Up and Down Arrow keys to highlight 1200 Baud and press the Enter key Ensure that the data settings are Data 8 Stop Bits 1 and Parity None 6 Press the F10 key to save the settings followed by the ESC key twice to complete the Smartlink Receiver SCU installation and return to the Main Screen Note This process must be repeated for multiple SmartLink Receivers i e you can only use one SmartLink Receiver SCU per Port 3 8 On Site Paging Setup 1 From the Main Screen go to Maintenance then System Configuration then Port and press the Enterkey 2 You will now be presented with the relevant Port Configuration Screen Select any available port normally a Transmitter is set to Port 2 and press the Enter key twice Make sure that the Paging Transmitter is connected to the appropriate port e g port 2 of the 4 Port Serial Card and that the antenna is conne