1. Drawing TPC413 Issue 1 1 Date 22 01 14 HGR1500 INDUSTRIAL DEHUMIDIFIER USERS MANUAL www eipl co uk Page 1 of 12 Drawing 1TPC413 Issue veel Date 22 01 14 ORION PACKAGE CONTENTS Item Description Quantity 10272GR US Dehumidifier 1 3086144 Quick release hose coupling 1 3944110 PVC Tube 3 8 I D 7 8M TPC413 Manual 1 Page 2 of 12 Drawing TPC413 Issue veel Date 22 01 14 UNPACKING Thank you for deciding to purchase an Ebac dehumidifier Like the many tens of thousands of people who have already bought an Ebac dehumidifier we are confident you will find it is the most effective answer to the problem of condensation and dampness related problems Carefully remove the HGR1500 dehumidifier unit from its transit box and visually check for signs of transit damage If there is evidence of damage DO NOT attempt to operate the unit call your supplier for advice Do not discard the packing it will be useful when transporting the dehumidifier unit in the future Your dehumidifier is packed in a plastic wrapping please ensure that it is disposed of safely and where it will not be a danger to children INTRODUCTION This user manual tells you how to use the HGR1500 dehumidifier Please read it thoroughly before operating the dehumidifier If you have any questions about the unit please contact our Customer Services Department at the address shown at the back of the section or p
2. RRANTY REGISTRATION DATE MODEL S N RECEIVED To ensure that your Ebac Dehumidifier is OWNER accorded the full ADDRESS coverage provided by this warranty please CITY STATE ZIP complete and mail this COMMENTS card at your earliest convenience Ebac Industrial Products Tha n k Yo u 700 Thimble Shoals Boulevard Suite 109 Newport News Virginia 23606 2575 Page 11 of 12 gt UK Head Office American Sales Office Ebac Industrial Products Ltd Ebac Industrial Products Inc St Helens Trading Estate 700 Thimble Shoals Blvd Bishop Auckland Suite 109 Newport News County Durham Virginia 23606 2575 DL14 9AD USA Tel 44 0 1388 664400 Tel 01 757 873 6800 Fax 44 0 1388 662590 Fax 01 757 873 3632 www eipl co uk www ebacusa com sales eipl co uk sales ebacusa com Page 12 of 12 Drawing TPC413 Issue veel Date 22 01 14 German Sales Office Ebac Industrial Products Ltd Gartenfelder Str 29 37 Geb ude 35 D 13599 Berlin Germany Tel 49 3043 557241 Fax 49 3043 557240 www eip ltd de sales eip ltd de
3. YING Ensure that all External doors and windows are closed Where no doors or windows are fitted temporarily screen off the openings POSITIONING For small areas position centrally in the area to be dried for larger areas such as open plan buildings offices or factories a number of dryers may be required in such cases they should be spaced evenly around the area Ensure that no unit is positioned in such a way that it blows directly into another For private houses or flats position the dryer on one floor at a time starting at the lowest floor closing all internal doors on the floor previously dried Continue until all floor levels have been dried Note when a particular damp patch is to be dried out the air outlet grille should be directed towards that area but should never be closer than 1m to the surface At no time should the inlet or outlet grilles be covered or obstructed DRAINAGE Under most operating conditions water will be produced continuously and it is important that it is drained away correctly and not allowed to spill Any spillage will evaporate and will therefore have to be recycled through the dryer again which in effect only prolongs the drying period PORTABLE CONTAINERS Position a closed top container underneath the water discharge pipe approximately 25 litres capacity Place a short length of pipe one end over the discharge pipe and the other end in the container Use a transparent container this wil
4. ed with a defrost control device When the unit is operated in ambient of less than 15 C a defrost cycle should occur approximately every hour The exact time is impossible to predict as the unit is fitted with a temperature sensitive defrost control During the defrost cycle the high pressure hot gas from the compressor is diverted into the evaporator coil where it melts the ice which has formed on the evaporator coil Page 7 of 12 Drawing TPC413 Issue veel Date 22 01 14 SAFETY e DO NOT Use the unit if the cabinet or power cord is damaged e DO NOT Insert objects into any of the grilles on the machine e DO NOT Cover or obstruct airflow from the grilles e DO NOT Operate the unit with the covers removed e DO NOT Attempt any repairs should the unit fail to operate e DO NOT Stand on the unit e DO NOT Attempt to lift heavy units unassisted e DO Check the plug on the equipment matches the supply e DO Use this unit for the purpose for which it was designed e DO Ensure the power cord and supply is earthed correctly e DO Check the voltage selection before attempting to power up the unit Dual voltage units only e DO Use a Residual Current Device RCD where possible SERVICE The machine should be serviced by qualified Ebac personnel or other persons having technical competence in servicing refrigeration equipment following the instructions in the Ebac service manual SPARES Full spares parts listings a
5. he room The HGR1500 dehumidifier is a robust compact unit designed to control the humidity in the enclosed space in which it is placed The unit is thermally protected and will switch off for a period if maximum operating temperature of 40 C is exceeded ELECTRICAL CONNECTIONS WARNING THIS APPLIANCE MUST BE EARTHED WIRING Connect the power mains cable plug of the dehumidifier unit as follows Brown Live Blue Neutral Green Yellow Earth ground As the colour of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminal in your own plug proceed as follows The wire which is coloured Green and Yellow must be connected to the terminal marked E or by the Earth symbol or coloured Green or Green and Yellow The wire which is coloured Blue must be connected to the terminal in the plug which is marked the letters N or coloured Black The wire which is coloured Brown must be connected to the terminal which is marked with the letter L or coloured Red You must safely dispose of the non re wireable plug once it has been removed from the flexible cord It is dangerous to attempt to insert the plug into any electrical socket CHANGING THE FUSE 13 Amp fuses that are ASTA approved to BS1362 should only be used NON REWIREABLE PLUGS The fuse cover must be refitted after the replacement of the fuse Page 4 of 12 Drawing 1TPC413 Issue veel Date 22 01 14 BASIC STEPS FOR DR
6. hone 01388 664400 Dehumidifiers remove moisture from the air circulating through it Continuous operation reduces the relative humidity the air and this helps prevent rust rot mould mildew and condensation The HGR1500 dehumidifier consists of an air to air heat exchange motor compressor unit a refrigerant condenser and air circulating fan a refrigerated surface a means for collecting and disposing of the condensed moisture and a cabinet to house these components GENERAL The HGR1500 dehumidifier must only be stored and transported in the horizontal position To operate stand the unit on level ground and connect power supply and it is ready for operation When a generator is used to supply the power it is essential to check the minimum kva required in the technical section within this manual The generator must be started before connection is made to the dehumidifier Page 3 of 12 Drawing TPC413 Issue veel Date 22 01 14 OPERATION The fan draws the moist air through the refrigerated surfaces which cools it below its dew point removing moisture which is collected and lead away The cool air then passes over the hot condenser where it is repeated With the addition of other radiated heat the air is discharged into the room at a higher temperature but a lower relative humidity than when it entered the unit Continuous circulation of the room air through the dehumidifier unit gradually reduces the relative humidity in t
7. l enable you to check the level of water and so prevent overflowing As the unit will be running for long periods of time a regular check should be made on the container water level PERMANENT DRAINAGE Connect a flexible hose to the water drainage pipe of sufficient length so that it will reach a permanent drain The gravity head created will allow for a gradual fall from the unit to the drain Ensure that the hose is free of kinks and is not allowed to rise at any point above the level of the discharge point from the dehumidifier Any air locks which may be created should the level be raised by the hose passing over obstructions could cause the water to back up the hose and spill from the drier Page 5 of 12 Drawing TPC413 Issue Se Date 22 01 14 SWITCHING ON Plug the unit into the power supply and switch on Set the illuminated Rocker switch to the ON SWITCHING OFF Set the illuminated Rocker switch to the OFF position Turn off the power supply and disconnect Page 6 of 12 Drawing TPC413 Issue veel Date 22 01 14 SPECIAL FEATURES DEFROST OPERATION If the ambient temperature of the room in which the dehumidifier is conditioning falls below 15 C ice will form on the evaporator coil as the air passes over it Over a period of time this build up of ice will effect the efficiency of the dehumidifier on its ability to maintain the required set conditions within the room The HGR1500 is therefore fitt
8. nd Ebac Service Manuals are available upon request by contacting one of the Ebac Service Centres listed in this manual OZONE FRIENDLY The gas which is inside the hermetically sealed refrigeration circuit is R22 which is an HCFC Under No circumstances should this gas be released into the atmosphere The unit should be serviced by trained personnel who will reclaim the removed gas DISPOSAL OF UNIT At the end of the machines working life the refrigerant must be disposed of in the correct manner Page 8 of 12 Drawing TPC413 Issue veel Date 22 01 14 SPECIFICATIONS Units Of 10272GR US Measure HEIGHT 21 5 Inch WIDTH 21 Inch DEPTH 35 6 Inch WEIGHT 165 Lbs AIRFLOW 295 CFM VOLTAGE 115 V PHASE 1 FREQUENCY 60 Hz MAXIMUM POWER 900 W MAXIMUM CURRENT 8 A GENERATOR SIZE 1 5 Kva FUSE RATING 13 A EFFECTIVE VOLUME 300 m3 REFRIGERANT TYPE R407c REFRIGERANT 0 585 Kg QUANTITY NORMAL 105 PPD EXTRACTION Noise Level Less than 70dB A when running Finish Epoxy Coated Zintec Steel Mobility Light in construction and easily positioned Normal Rated Extraction at 54 F 70 RH Condition This product contains fluorinated greenhouse gases covered by the Kyoto Protocol The refrigeration system is hermetically sealed The Global Warming Potential GWP of refrigerants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant c
9. ontained in this unit please refer to the product data label Page 9 of 12 Drawing TPC413 Issue veel Date 22 01 14 CONTACTING EBAC CUSTOMER SERVICES If you have nay further queries please contact the Ebac Customer Services Department on 01388 664400 and have the following information at hand e Part Number and Serial Number of the machine located on the rating plate and the front of the machine e Full name and address e Where your machine was purchase Page 10 of 12 Drawing TPC413 Issue veel Date 22 01 14 LIMITED WARRANTY Our products carry a one year unconditional warranty against any defects in workmanship or material This warranty will cover all parts and labour required to repair your Ebac product This warranty is invalid if the unit has been abused damaged whether intentional or accidental or if any modifications have been made to the unit THE FOREGOING WARRANTY IS EXCLUSIVE AND IS ISSUED IN LIEU OF ALL OTHER WARRANTIES WHETHER WRITTEN ORAL OR IMPLIED INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE EBAC INDUSTRIAL PRODUCTS INC DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL DAMAGES LOST PROFITS OR INCIDENTAL DAMAGES FOR BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THE FOREGOING DESCRIBED MERCHANDISE For Your Records Model S N Date Received SAVE THIS SECTION FOR YOUR RECORDS CLIP AND RETURN THIS CARD PLEASE NOTE WA