Home

SK608B Owners Manual

image

Contents

1. HF Motion Sensor Power Controller SK608B User Manual General The SK608B is an active motion sensor that emits high frequency waves 5 8GHzZ The sensor detects the change in the echo return and is sensitive to movement in its detection zone The SK608B is designed to be used in a device or system and must not be operated without appropriate protective covering If after reviewing this guide you require additional information or assistance please contact Eco Heat Equipment at info ecoheat co za 27 0 861 999 887 or www ecoheat co za Technical Specifications Voltage 220 240V AC Frequency 50 60Hz Motion Sensor HF system 5 8GHz CW radar ISM band Motion Sensor transmission power lt 0 2mW RF power Light load Incandescent 1 000W Fluorescent 300W Detection Range 2 10m Detection Angle 360 Light level 10 500 LUX Time setting 10 seconds 30 minutes Safety Any incorrect use or installation procedure not recommended by the manufacturer may cause fire electrical shock or injury to persons Box Contents Your box should contain the following items HF Sensor Installation Instructions Note Do not install the motion sensor on unstable or vibrating surfaces or near doors and windows where outside movement may be detected Motion may be detected through ceilings drywall wood or plastic WARNING THE SK608B IS DESIGNED TO BE A COMPONENT IN A DEVICE OR SYSTEM AND IS NOT SUI
2. IME time delay after motion sound until shut off 3 LUX LIGHT level of ambient light sensitivity The three adjustments settings are as follows Detection range 2m to 10m Time setting range 10sec to 30min Lux light sensitivity 10 to 500 LUX There are 8 settings on the motion sensor that control the range time and lux SENS S1 S2 TIME S3 S4 S5 LUX S6 S7 S8 Step 1 Adjust the detection range of the motion sensor The detection range is the term used to describe the radius of the circular detection zone produced on the ground after mounting the unit at a height of about 2 5m 1 of 2 ON position 1 OFF position 0 WARNING If the sensitivity is adjusted too high the sensor will pick Up movement such as curtains blowing in the wind small animals or movement through windows and thin walls If the sensor is too sensitive adjust the detection range lower Step 2 Adjust the time setting of the motion sensor The time setting will determine the time that needs to lapse before the motion sensor switches off due to lack of movement in the detection area Any movement detected during the time setting will restart the timer and keep the connected device on ON position 1 OFF position 0 4 5 SENS S3 S4 S5 Step 3 Adjust the lux setting of the motion sensor if applicable The lux light sensitivity can be used to ensure the unit only operates during minimum lux settings The lux
3. TABLE TO BE USED IN ITS CURRENT FORM EBSURE THE USE OF THE SK608B IS IN ACCORDANCE WITH NATIONAL AND LOCAL ELECTRICAL CODES AND STANDARDS Sensor calibration Note Allow up to 1 minute for the motion sensor to recalibrate after it has been connected for the very first time This is only necessary during installation or when the mains supply is disconnected Note After the connected device switches OFF it takes approximately 4 seconds before it is able to start detecting movement again The connected device will only switch on in response to movement once this period has elapsed Wire diagram Neutral O N to Neutral l Live In to L Eco Heat Equipment September 2015 Operation and Field of View The motion sensor detects motion within its coverage area and controls the associated load connected to the sensor For best performance persons or objects moving towards the sensor are ideal Detection is possible through wooden doors panes of glass dry wall ceiling tiles or thin brick walls Beware of windows facing passages or roads Ceiling Mount Wall Mount side view Wall Mount top view Motion Sensor Settings and Adjustments The motion sensor is a high frequency HF type electronic occupancy detector which in turn switches a load when connected to the motion sensor There are three adjustments that can be made to influence the operation of the motion sensor 1 RANGE motion detection range 2 T
4. hatsoever nature whether consequential or not either contractual sustained to or caused by or which may arise through the use of any comments suggestions circuitry services or equipment offered for purchase The User indemnifies the author and supplier and agrees not to hold him her responsible for any damages losses and or liabilities including legal costs on a scale as between attorney and user arising from or through the use of circuit diagrams equipment and services whether such circuit diagrams equipment and services were used with the consent of the User or not All risks attached to the use of circuit diagrams equipment and the connection thereof to the User s equipment shall be deemed to have passed onto the User once having purchased such equipment from the author or supplier A ecosensor 2 of 2
5. on range setting on detection zone and reduce detection range permanently The sensor is not sensitivity mounted correctly for b Check detection range setting reliable operation and mounting procedure Wrong LUX LIGHT level c Adjust setting on the LUX LIGHT setting settings Time setting control is set d Adjust the time setting control too high Unit may be faulty e Contact Eco Heat Equipment Warranty The sensor has a three 3 year warranty after the date of the original purchase Please keep your original receipt as this will be required for any claims under this warranty The warranty is a strictly carry in policy The sensor s must be returned to Eco Heat offices for a claim to be processed The warranty does not cover damage from misuse neglect or abuse products that have been modified in any way shipping and handling cost associated with the product damage resulting from accidents lightning fire water power surges natural disasters and or incorrect installation For more information view the Return Refund Policy at ecoheat co za terms ohp Due to minor improvements in design or otherwise the product you purchase may differ from the one shown in this leaflet For more information or advice on this or any other Eco Heat Equipment products visit www ecoheat co za or phone 27 0 861 999 887 Indemnity The Author and supplier shall not be held liable for any loss injury or damage of w
6. setting can also be disabled by setting it to the 24hr position S6 0 S7 0 S8 0 meaning the lux light level will have no effect on the operation of the unit ON position 1 OFF position 0 AB S H 100LUX 7 300LUX 500LUX LUX S6 S7 S8 WARNING Controlling a load in excess of the specified ratings will damage the unit and lights and could pose risk of fire and electric shock WARNING Do not install this unit to control a power socket OTHER CAUTIONS Disconnect power when working on electrical outlets or components Do not push on the surface of the lens Cleaning Carefully wipe sensor with a soft damp cloth Recycling Please recycle all packaging material that came with the motion sensor Eco Heat Equipment September 2015 Trouble Shooting Malfunction Possible Cause The unit will No mains power not switch No movement is Move towards the unit in on detected in detection detection zone or increase the zone detection range settings Wrong LUX LIGHT level Adjust setting on the LUX LIGHT setting settings Electrical circuitry faulty Refer to the Electrical Electrical Installation not Installation section to ensure done correctly correct installation Unit may be faulty Have a certified electrician disconnect and test the unit Contact Eco Heat Equipment Check mains power is on Unit stays Continuous movement in a Check detecti

Download Pdf Manuals

image

Related Search

Related Contents

iCOCOA User's Guide - Paris - Rocquencourt  Descargar ( 2492k )  Epson Textile carrying case K28  Guide d`installation - Silex Technology America  V7 WM1F175 flat panel wall mount  Descargar PDF - KD Soluciones  083① RSN    AD-5682  Belkin 8-Port Gigabit Switch  

Copyright © All rights reserved.
Failed to retrieve file