1. Acceleration feedforward gain KF Velocity feedforward gain KP KI KD PID gains for servo control loops LD Load parameters from flash MO Motor enable disable necessary to change some configuration parameters Page 16 of 23 Acuity Technologies ISS User s Manual Rev 1 3 MS Motion status PA Move to absolute position PE Position error PR Move to relative position PU Power up behavior PV Report present velocity PX Report present position RS Soft reset SR Status reporting level ST Stop motion immediately and hold position SV Save parameters to non volatile flash TC Torque motor current command TM System time TR Target radius UB Baud rate VE Velocity error 4 2 1 Servo Command Descriptions When using the motion control commands JV PA and PR each motion mode starts with its entire set of applicable parameters and limits HL N and LL N Starting a point to point motion uses the present limit settings of acceleration smoothing jerk acceleration deceleration speed and position Therefore these parameters should be set to the desired values before initiating a motion Maximum magnitude of all parameters must be lt 2 1 unless otherwise noted A few commands are available in binary format Binary values of 2 bytes or more are in little endian abbbb Move Servo Binary Command Send a torque speed or position command This command is composed of binary values so it cannot be issued from a keyboard It is u
2. Servo Proportional Integral Derivative gains The IS servo controllers implement PID control with an optional feedforward term The controllers and motors are tuned to perform well with most loads For highly inertial loads it may be appropriate to reduce the proportional and integral terms to reduce overshoot or oscillation These parameters can be read and adjusted through the KP KI KD KA and KF commands Page 20 of 23 Acuity Technologies ISS User s Manual Rev 1 3 Warning Changing these parameters can result in violent unstable motor motion We recommend setting low limits for maximum positive and negative motor current before experimenting with these values Keep in mind that the position speed acceleration and current limits can affect servo dynamics for large movements Test stability with small motions before trying large movements or high speeds LD Load Parameters from Flash Reads the stored servo parameters from non volatile memory and set the active parameters to the retrieved values See also SV and FD MO Enables and disables freewheels motor power MO 0 disables the motor This is the idle state of the drive The power stage is disabled and no current flows in the motor MO 1 is the operative state of the servo drive driving the motor and activating and executing the programmed motion When first enabled the servo holds its current position MO 1 must be given before a motion command will move the servo If MO is set
3. Standalone RS 232 Voltage Input Servos Servos ordered as standalone units can be controlled via RS 232 or a 10V differential input signal They are configured via RS 232 commands See the Servo Commands section of the Command Set chapter 3 3 1 Standalone Servo Connector Locations and Pinouts ISL Servo ISS Servo 8 Pin Control C t ae 4 Pin Power 8 Pin Control Connector Connector 4 Pin Power Connector Pin Wire Function Orange AN Pin Wire Function 2 Lt Orange AN White in 3 Green H 2 Brom GND 4 Lt Green H 3 Green Vin 5 Blu 4 Yellow GND 6 Lt Blue TX 7 Brown RS Return 8 Lt Brown NC Standalone Servo Control Connector Standalone Servo Power Connector 3 3 2 Standalone Servo Analog Voltage Input Maximum operating differential voltage 10V Maximum absolute differential input voltage 16V Differential input resistance 3 74 Kohms Analog input command resolution 14 bits Using the Analog Input To use the analog input to control position speed or torque the serial command UM must first be used to select the analog input as the control source and configure it as desired Driving the Analog Input with a Single Ended Source Page 9 of 23 Acuity Technologies ISS User s Manual Rev 1 3 To use the differential analog input with a single ended source AN should be connected to the signal source and AN to ground at the signal source location with a twisted pair 3 3 3 Standalon
4. a two letter code which in some cases is followed by an index specifier an sign and a parameter value Commands must be terminated by CR LF or semicolon AD NN Set new servo address AP NN Map PWM input to servo EN NSC Echo on off NR Set query NSC status reporting level NS Query Network status knabbbb Move servo binary command SB A Set NSC baud rate SS AA Select servo TS Synchronize Time UK Universal kill motor command US Universal stop motion command 4 1 1 NSC Command Descriptions Set NSC Baud Rate SB A Sets reports the NSC host port baud rate Valid values are Page 13 of 23 Acuity Technologies ISS User s Manual Rev 1 3 0 4800 1 9600 2 19200 3 38400 4 57600 5 115200 When the NSC or a serial standalone servo powers up it looks for a stream of Space ASCII byte code 32 characters at 9600 baud If a stream of spaces is detected it will set its baud rate to 9600 which is also the default If the first of a stream of 5 space characters is not detected within 250 ms it will set its rate to the value for which it has been configured and begin accepting commands This allows a user to establish contact with an NSC whose baud rate setting is unknown or does not match that of the host by powering it up while transmitting space characters or holding down the space bar when using a terminal emulator set to 9600 baud Note that an SV command must follow this command to make the change permanent Ba
5. accept 1 2 ms PWM signals at up to 500 Hz When pulses are received the same width pulse is transmitted to the mapped servo channel if the input has been mapped to a PWM address If the input has been mapped to an IS address the command is interpreted as a torque speed or position signal for that IS servo In torque mode pulse widths of 1 to 2 ms is mapped to a current range of the value specified in the last current limit command PWM inputs outside the 1 to 2 ms range will be limited or clipped to 1 or 2 ms before generating the servo signal Servos are shipped with the current limit set appropriately so current limits should only be modified if reduction in peak torque is required Page 10 of 23 Acuity Technologies ISS User s Manual Rev 1 3 3 5 NSC Front Panel The NSC connectors described below are mounted on the NSC front panel SERVO1 SERVO2 SERVO3 SERVO4 SERIAL1 SERIAL2 AUX1 AUX2 POWER RS 232 or RS 422 Host Interface Reserved Do not connect 4 PWM outputs 8 PWM inputs 12 PWM outputs Green Power LED Red Status LED NSC Front Panel 3 5 1 NSC Power Connector The large power connector on the NSC 60 is capable of 30 Amps on each of its 2 power and ground pins The smaller power connector on the NSC 20 is capable of 10 Amps per pin 3 5 2 Cable Plug The pinout of the plug on the power cable supplied with
6. detected This is normal when no servos are connected If it blinks when servos are connected it may be due to improper network geometry or missing termination plugs The red LED is normally off If the Red LED flashes there is a servo error The LED will flash the number of times indicating the address 1 to 20 of the servo with a fault pause and repeat If more than one servo has a fault the lower numbered servo will be indicated Transient faults such as momentary position errors may not be indicated but will appear in status messages from the NSC to the host 4 Command Set 4 1 NSC Commands The NSC accepts commands for itself and the servos connected to it over the 232 or 422 serial port The commands in this section are executed by the NSC and may generate a sequence of commands to a servo Except for the Move Servo command all commands are in ASCII These consist of ASCII command codes and command parameters The commands in the section Servo Commands have the same syntax and can be used with standalone servos or in networked systems In a networked system they are passed directly to the servos through the NSC The servo to which commands apply is specified with the SS Select Servo command Servo responses are relayed through the NSC Servo heartbeats are followed by a two character servo address identifier from 01 to 32 Reponses to queries can be assumed to come from the currently selected servo ASCII NSC commands consist of
7. it does all servo activity See the NSC command NR Status reporting command parameters are formed from 3 digits The first controls error reporting the second controls command acknowledgment and the third controls periodic heartbeat transmission 1XX Send no error messages to host 2XX Report hard servo errors only default 3XX Report hard and soft servo errors X1X Send no command acknowledgements X2X Send an error message if servo command is invalid default X3X Send an S acknowledgement to each valid servo command or an error message if invalid XX1 Send no K heartbeat default XX2 Send K heartbeat once every second XX3 Send K heartbeat once every 0 1 second XX4 Send K heartbeat once every 0 01 second XX5 Send K heartbeat once every 0 001 second Standalone Servo Heartbeat Single K character sent over serial port Network Servo Heartbeat 5 bytes 1 byte CAN ID followed by EE99 See the EC command for error code meanings ST Stop motion immediately and hold position Emergency stop and hold position Decelerates as allowed by the peak current limit and hold position when stopped To stop using the motion smoothness parameters use the JV 0 command To disable motor power immediately use the MO 0 command SV Save parameters to non volatile flash Saves the currently active servo parameters to non volatile memory overwriting the stored values Does not a
8. its settings and the NSC will always relay these messages as it does all servo activity See the servo command SR The NSC status configuration applies only to NSC status and error conditions Status reporting command parameters are formed from 3 digits The first controls error reporting the second controls command acknowledgment and the third controls periodic heartbeat transmission 1XX Send no NSC error or status messages to host 2XX Report NSC hard errors 3XX Report NSC hard and soft errors default X1X Send no command acknowledgements X2X Send an error message if NSC command is invalid default X3X Send an A acknowledgement to each valid servo command and an error message if invalid XX1 Send no N heartbeat default XX2 Send N heartbeat once every second XX3 Send N heartbeat once every 0 1 second XX4 Send N heartbeat once every 0 01 second XX5 Send N heartbeat once every 0 001 second Error Codes 50 Normal operation Sent only in response to an NS command Soft Errors 51 Can Bus Soft Error retried successfully Hard Errors 52 Can Bus Hard Error 53 Servo Communication Failure an expected response or heartbeat was not received Error code 53 is followed by a 2 character servo address 01 to 32 NS Query Network Status Returns one of error codes 50 53 Heartbeat N This is a single character message from the NSC not a command If status repo
9. neither connector of a pair is used it is not necessary to terminate the pair Termination plugs however may be used to seal the unused connectors e The last servo in each chain must have a termination plug in the unused connector 6 Connect the serial cable from the NSC to your host computer If the NSC is equipped with an RS 232 port a straight through serial cable is needed and may be ordered as an option If the NSC is equipped with an RS 422 port the dual twisted pair cable may be ordered as an option Ensure that the cable is wired appropriately for the pinouts of your host connector 7 Reapply power The NSC green LED should come on and stay on The red LED should remain off 8 Initiate communication with the NSC through a terminal emulation program or the demonstration software supplied See the NSC and servo command set for commands and queries 2 2 Standalone RS 232 Voltage Input Servos 1 Connect the power and voltage input signal or RS 232 host to the servo cables 2 Plug the cables into the proper servo connectors 3 Turn on system power A new servo will center and hold that position in the absence of an input signal or command from the RS 232 port Position will change over 45 degrees as a 10V differential signal is applied or position commands are issued over the serial port The servo should echo serial commands received Page 7 of 23 Acuity Technologies ISS User s Manual Rev 1 3 3 Component Desc
10. should ensure that this does affect operation of the BT command CLIN Current limits Set the instantaneous peak and continuous current limits Note that if these values are changed it is possible to damage the motors in some servo models If the continuous current limit is exceeded for more than 2 7 seconds the current will be reduced to the continuous current limit If a motion command attempts to drive the current above the peak current limit the current will be limited to the peak current limit CL O sets reports the maximum peak current in amperes Valid limits are 0 to 6 6 amperes CL 1 sets reports the maximum continuous current in amperes Valid limits are 0 to 3 3 amperes EB Query error code binary Reports the current error status of the servo as an E character followed by a 32 bit binary long word Each error condition is reported with a corresponding bit in the long word set See EC for error descriptions EC Query error code ASCII Reports the current error status of the servo as an ASCII string of 32 1 or 0 characters Each error condition is reported by one character Hard errors will shut down the drive To re enable the drive ensure that the cause of the problem has been corrected before re enabling it by sending the MO 1 command Error Codes Normal operation 0000 0000 0000 0000 0000 0000 0000 0000 Hard Errors Hard CAN bus communication failure 0100 0000 0000 0000 0000 0000 0000 0000 Pow
11. to 1 and the motor is already on nothing happens MO is set to zero when a hard error occurs See the EC error status query Note When PU 1 or PU 2 the servo drive will attempt to start set MO 1 automatically after power on MS Motion Status Query the current status and target value Responses are In JV command JV speed In PA command PA destination In PR command PR target In TC command TC torque Holding position HL position Homing HO 1 Motor off MO 0 MS is a query command only Any parameter is ignored PA Absolute Position Reports last PA commanded or commands motion to the specified target position If a PA PR JV or TC command is being executed is aborted and the motion takes place immediately The drive moves to the desired target position as fast as possible subject to the jerk speed and acceleration limits See HH and HL commands See also PR Relative Position PE Position Error Reports the current position error when the motion status is MS is PA PR JV or HL This is the error in the PID motion control loop not the difference between the target location of a PA or PR command and the present location PR Command Relative Position Reports last PA commanded or moves the distance specified from the current position If a PA PR JV or TC command is being executed is aborted and the motion takes place immediately from the current encoder position If the servo is holding at a target location
12. Acuity Technologies ISS User s Manual Rev 1 3 Acuity Technologies Intelligent Servo System ISS User s Manual Acuity Technologies I nc 3475 Edison Way Bldg P Menlo Park CA 94025 www acuitytx com Page 1 of 23 Acuity Technologies ISS User s Manual Rev 1 3 TABLE OF CONTENTS WARRANT Vivscccccscsssccss sicesosichesscpucececcvstivssscssatecesssssessuacescssccesiscssdesssasbsecessieseseseshvescsisedasssbiseeccphcctovesesndessstusiecedssbeesstaces 3 Ae OVER VUEW sssess scsetistesisatasdesssesesscesssuessiece seasons sstecevecsaceseesssesauecesduccs E E 5 1 1 SERV D NA EEEE A ARE NEE A EEE E EE AE E EE S A E a chat E E 5 1 1 1 LANTO A RTA AO EEEE EAEE AEE EAEE EEE EA 5 LEQ Standalone Voltage RS232 SCrvOS isscvvcscsscsecsasveseigsisesiensisasscecssueseviscesecpscseatessisaseensdsuas esbasisoeysapeutosesees 5 1 2 NETWORK SERVO CONTROLLER scsssccscceceessssececececeessnecececccseneaecesececseseaacesececsesesseaeceeeceesesssaeeeeeceesensaaeees 5 1 3 USE AND MAINTENANCE c cccccccssssstcecececeessnaececccecsessaeeeeececseneaaececececeeseaaeaecececeesesaeaeceeeceeseasaeseeseeeseneaaeees 5 2 HARDWARE POWER UP ssscsscsscsesdssssasssescosssissasoessceseieadecssesecensssesieesbecesoosececsoesvesessusesesdessbecsssesedesdeeseassseessesas 6 2 1 SERVOS WITH NETWORK SERVO CONTROLLER sssssscesececsessssececececeesennsaececececsessaueceeececeensaaseeseeeceenenseaeees 6 2 2 STANDALONE RS 232 VOLTAGE INPUT SERVOS ccccccccccecseses
13. P host src host demo program source code and MS C C solution 6 Servo Interface Application The Acuity Servo Interface for Windows XP is an interface for communication through a serial port with the NSC or with a standalone servo is found in the bin directory of the distribution CD This provides a simple interface for configuring servos and trying out motion commands Page 23 of 23
14. ale or other proof of purchase your name address description of the problem s Print the RMA number you have obtained on the outside of the package Page 4 of 23 Acuity Technologies ISS User s Manual Rev 1 3 1 Overview The Intelligent Servo System consists of servos and network servo controllers position and motion control components for aerospace robotic and automation uses The servos may be purchased as standalone units or for control by the NSC network servo controller The Network Servo Controller NSC configures the servos supplies power and CAN bus control for the servos provides a single point serial host computer interface for multiple servos and facilitates coordinated motion between servos 1 1 Servos The IS servos have two case sizes and a range of torque speed combinations A network of up to 20 IS servos together with up to 12 third party PWM servos may be configured and controlled through the NSC Servos may be operated in torque speed or position control mode Servos are delivered configured for position control with a reconfigurable position range of 45 degrees 1 1 1 Networked Servos Networked servos are configured and controlled by sending commands to the NSC s RS 232 or RS 422 port Each networked servo has 2 connectors Either connector may be connected to the NSC or to another servo using ISS servo cables which provide power and CAN bus communications The last servo in a chain of servos must hav
15. arranties These limited warranties extend to the original purchaser and to no other purchaser or transferee Limited 90 Day Parts and Labor Warranty Acuity warrants this product and its parts against defects in materials or workmanship for a period of one year after the date of original retail purchase During this period Acuity will at its option repair or replace a defective product or part without charge to you THIS PRODUCT IS NOT CERTIFIED FOR AND IS NOT TO BE USED IN ANY LIFE CRITICAL MEDICAL HUMAN TRANSPORTATION OR OTHER APPLICATIONS OR PRODUCTS IN WHICH LIFE OR SAFETY HAZARDS MAY RESULT FROM USE MISUSE OR FAILURE OF THE PRODUCT Warranty Conditions The above LIMITED WARRANTIES are subject to the following conditions 1 Warranties extend only to products manufactured by Acuity 2 Warranties extend only to defects in materials or workmanship as limited above Warranties extend only to defects which occur during normal use and do not extend to damage to products or parts which results from alteration repair modification faulty installation or service by anyone other than an authorized Acuity service center damage to products or parts caused by accident abuse misuse or maintenance mishandling misapplication or damage caused by acts of God 3 You must retain your invoice bill of sale or other proof of purchase 4 Any replacement parts furnished at no cost to the purchaser in fulfillment of this warranty are warrant
16. d description of the SM commands refer to the Servo Command Set documentation below 4 2 Servo Commands The IS servos use a 2 character motion control command set The servo commands are the same whether communicating directly with a Standalone IS Servo or with a Network IS Servo through the NSC except that servos must first have addresses assigned and a servo must be selected using the AD and SS commands described above when using the NSC When communicating with a standalone servo NSC commands will have no effect Cautions Note that several non volatile servo parameters including current limits set with CL N are preset for the IS servos Exceeding the factory default values of these parameters may result in damage to the servo Standalone Servos The following commands are interpreted and executed by the servos In a networked system they are interpreted and relayed to the currently selected servo by the NSC Any servo responses are relayed to the host through the NSC BT Begin motion at specified time CLIN Motor current limitations EC Current error EH N EL N Position and velocity error limits ER Last Error ES Servo Echo on off FD Load factory default parameters from PROM HL N LL N Jerk acceleration speed and position limits HO Move the servo to the hardware home location or stop homing HV Homing velocity ID Set Report CAN node address IN Set Report motion command input source JV Jog at constant velocity KA
17. e Servo Home Input Standalone servos may be moved to their hardware home location by applying 3 3 to 5 V to the H input H is the return for the home signal and should be grounded If the servo is enabled it will move to its home position The Home input has an internal 10K pulldown resistor 3 4 Network Servo Controller 3 4 1 Servo Control The NSC can control IS servos as well as smaller pulse width controlled servos driven by RC style pulses 1 2 ms 50 400 Hz Up to 20 IS servos and 12 PWM servos may be connected 3 4 2 Servo Power IS servo power must be supplied on the main NSC power connector This power also supplies the NSC s internal electronics and host serial port The voltage input range is dependent on the version ordered 3 4 3 Controlling PWM Servos Power for any third Acuity or third party PWM servos must be applied to some of the V pins of AUX1 and or AUX2 or supplied to servos separately If less than 12 PWM servos are being driven the unused power ground pins on AUX1 and or AUX2 can be used as inputs Maximum current is 3 Amps per pin The twelve power pins on AUX and AUX2 are connected together internally but isolated from the rest of the NSC and may have 0 to 48V applied AUX1 and AUX2 ground pins are connected to NSC ground 3 4 4 Using PWM Input Signals Signals from a servo controller such as an RC radio receiver can be used to control IS or PWM servos attached to the NSC Eight input pins on the AUX2 connector
18. e a termination plug in its unused connector 1 1 2 Standalone Voltage RS232 servos If the standalone version of a servo is ordered one connector accepts RS 232 input for configuration and motion commands as well as an analog voltage input for torque speed or position control and a HOME command input line The second connector provides power to the servo Standalone servos are configured with commands similar to those used to control the CAN network servos but the commands go directly to the servo rather than to the NSC s RS 232 or RS 422 port Standalone servos are controlled individually and cannot be networked or connected to an NSC 1 2 Network Servo Controller The NSC Network Servo Controller has four functions Providing a single host interface for multiple servos implementing CAN protocol to distribute motion and configuration commands from the host processor to individual servos and relay status back to the host performing synchronized motion with multiple servos and supplying power to servos Configuration consists of functions such as selecting torque speed or position mode setting speed or position range limits and optionally setting motor current limits The NSC implementation of the CAN protocol allows the host system to communicate with a network of servos without the necessity of implementing CAN communication on the host or maintaining multiple serial ports on the host 1 3 Use and Maintenance Page 5 of 23 Acuity T
19. echnologies ISS User s Manual Rev 1 3 The ISS Servos and NSC controllers form a rugged system designed for use on mobile platforms However they should be protected from severe shock and vibration such as that which might be experienced on a vehicle without suspension or with high engine vibration In these cases the components should be mounted with the supplied grommets The servos are sealed with protection against rain washdown short term immersion to 1 meter in water and pressure differentials of one atmosphere It is not recommended that the servos be operated under water See the ISS datasheet for additional information 2 Hardware Power Up 2 1 Servos with Network Servo Controller A standard networked system consists of an NSC one or more IS servos a servo cable for each servo an NSC power cable and two or more termination plugs The NSC has four CAN connectors and up to five servos can be connected to each in a daisy chain configuration for a total of 20 servos Performing the following steps in this order will minimize the chances of damage to servos in the event of an error such as connecting to your power supply incorrectly or causing damage to plugs from high voltage arcing 1 Connect the NSC power cable connector to the NSC It is advisable to include a high power switch between the supply and the controller and to double check the supply connection polarity The NSC and servo plugs are not designed to act a
20. ed only for the unexpired portion of the original warranty ALL WARRANTIES REQUIRED TO BE IMPLIED BY STATE LAW ARE EXPRESSLY LIMITED TO THE DURATION OF THE LIMITED WARRANTIES SET FORTH ABOVE Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you WITH THE EXCEPTION OF ANY WARRANTIES REQUIRED TO BE IMPLIED BY STATE LAW AS HEREBY LIMITED THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES IN NO EVENT SHALL ACUITY BE LIABLE FOR SPECIAL INCIDENTAL CONSEQUENTIAL OR PUNITIVE DAMAGES INCLUDING WITHOUT LIMITATION INJURY OR DAMAGE TO PERSONS OR OTHER PROPERTY INCONVENIENCE LOSS OF GOODWILL LOST PROFITS OR REVENUE LOSS OF USE OF THISPRODUCT OR ANY ASSOCIATED EQUIPMENT COST OF SUBSTITUTIVE EQUIPMENT DOWNTIME COSTS OR CLAIMS OF ANY PARTY DEALING WITH PURCHASER FOR SUCH DAMAGES RESULTING FROM THE USE OF THIS PRODUCT OR FROM DEFECTS IN THIS PRODUCT OR ARISING FROM BREACH OF WARRANTY OR CONTRACT NEGLIGENCE OR ANY OTHER LEGAL THEORY Page 3 of 23 Acuity Technologies ISS User s Manual Rev 1 3 Procedures for Obtaining Warranty Service 1 Contact your Acuity distributor or call Acuity Technologies at 650 369 6783 to obtain a return merchandise authorization RMA number within the applicable warranty period Acuity will not accept any returned product without an RMA number 2 Ship the product to Acuity postage prepaid together with your bill of s
21. er circuitry short 0010 0000 0000 0000 0000 0000 0000 0000 Temperature limit exceeded 0001 0000 0000 0000 0000 0000 0000 0000 Power supply failure 0000 1000 0000 0000 0000 0000 0000 0000 Under voltage 0000 0100 0000 0000 0000 0000 0000 0000 Over voltage 0000 0010 0000 0000 0000 0000 0000 0000 Power up reset occurred 0000 0001 0000 0000 0000 0000 0000 0000 Motor commutation failure 0000 0000 1000 0000 0000 0000 0000 0000 Unknown Amplifier Error 0000 0000 0100 0000 0000 0000 0000 0000 EEPROM Read Error 0000 0000 0010 0000 0000 0000 0000 0000 Short Commutation and Over temperature errors require disabling the motor MO 0 or power cycling the servo to restore operation Soft Errors Bad command code received 0000 0000 0000 0000 0000 0000 0000 0001 Bad parameter value received 0000 0000 0000 0000 0000 0000 0000 0010 Continuous or peak current limit triggered 0000 0000 0000 0000 0000 0000 0000 0100 EEPROM Write Error 0000 0000 0000 0000 0000 0000 0000 1000 Page 18 of 23 Acuity Technologies ISS User s Manual Rev 1 3 Soft CAN error transmission retried 0000 0000 0000 0000 0000 0000 0001 0000 Position following error 0000 0000 0000 0000 0000 0000 0010 0000 Speed following error 0000 0000 0000 0000 0000 0000 0100 0000 Position limit error At or beyond limits on motion 0000 0000 0000 0000 0000 0000 1000 0000 Speed limit error At or beyond limits on motion 0000 0000 0000 0000 0000 0001 0000 0000 EH EL Error High Low Limits Set rep
22. ffect the factory default values See also LD and FD Page 22 of 23 Acuity Technologies ISS User s Manual Rev 1 3 TC Torque motor current command Direct control of motor current Valid command values are CL O to CL O TM System Time Set report the servo time If the time is not set the servo s time is in milliseconds from power up System time is not preserved across power cycles Note The servo time in milliseconds is a 32 bit value and will wrap around when the time value reaches 27 1 milliseconds Users should ensure that this does affect operation of the BT command TR Target Radius Set report the distance from position target for deciding that a motion is complete when executing a PA or PR command Range is 0 to 65535 The MS query will return Holding position once the servo has arrived within this radius of the target position and the speed has reached zero The MS state will not change until the next motion command regardless of motion from external disturbances The holding error can be read using PE UB Baud Rate Set report the current baud rate in serial interface servos Values are 0 4800 Baud 1 9600 Baud 2 19200 Baud 3 38400 Baud 4 57600 Baud 5 115200 Baud Baud rate of CANBus servos cannot be changed 5 CD Directory Structure The NSC and servos come with a CD with the following contents doc This users guide and servo datasheet bin precompiled GUI driven demo for Windows X
23. h to zero allows unlimited rotation Position limits and speed limits are enforced in all types of motion Acceleration and jerk limits are enforced only in PA and PR moves The jerk limits are used to set the rate of acceleration in PA and PR moves The position and speed limits are enforced in three ways First a position or speed motion command with a parameter that exceeds the limits will be rejected as invalid Second path planning is performed such that if the planned trajectory will cause commanded speeds or positions outside the limits the trajectory is altered Third actual speed and position are checked at 1 millisecond intervals and commanded motor Page 19 of 23 Acuity Technologies ISS User s Manual Rev 1 3 power is limited to generate only those motor currents that will accelerate away from the limit reached For example reaching a positive limit will clip signed commanded motor current to zero or less It is possible for an external force or inertia to carry the speed or position past the limits set No power is applied to the motor for enforcing limits HO Home Reports whether the servo is homing or moves the servo to the encoder home location HO 1 and then sets the servo position to zero or stops homing HO 0 Servos may be configured to home on power up or only on receipt of this command HV Home velocity Sets reports the speed at which the servo will home Range gt 0 and within the velocity limits in
24. i EAS EE ESEE SEE AEE EEEE ESEESE OES EEE EEE EEEE E OEA ESEAS E ET EEE 11 3 5 1 NSC Power CONNEC CLOT ric a Se ea en at a MED aa es Stites Il 3 3 2 Cab esPLUG o nro E EEE EEEE AEA OESE vevens EAEE EEE N EEE OSEA EAEE lobes EEEE S ll 3 6 SERIAL AND AUXILIARY INPUT CONNECTORS cscsessssecececsessaececececsessnececececsesesssceeececeesesnsaeeeeseeesenseaeees 12 3 6 1 NSC Front Panel LEDS ccccccccscccscesesecsescssscecssccccesscssscssssnsscscscscscscsscssssssscssscssscsesssesssssssesesesesesssesssssees 13 4 COMMAND SET wvvscsssscesscsecsssecistsossctncssdentassessededestecissenseesesvstenssonsssedseessossuveessedescedeubsdsosssiedsodsedesessecdeesebestessess 13 4 1 NSO COMMANDS a a a a ea ea Es 13 411 NSC Command Descriptions csiscasissssessussaseisasiscestentassases shee ches sdreasbocosntvng SE ees PE CEDE pE a EEES SEPE 13 4 2 S15 AOA SIV IN FANNI DA RAEE E E EE ELTE A EEE E A EE A E E E 16 42 1 Serv Command Descriptions ois cssicsssessescasecsnssasesiosiass cies saseshnondreqsessssvtvossassadyesasecbuscdseavessusnduvesaseasheaes 17 5 CD DIRECTORY STRUCTURE bissssscsssecssssssesssssesscssveczssessectesesbecsstnssecsssesseesssecssesesosssessaecssosssesssnsessosvdecsssses 23 6 SERVO INTERFACE APPLICATION sssccssssssscsssssccssssccssssscccssseccscsscccsessscccessacccesscassscsaceccssseccscsssseces 23 Page 2 of 23 Acuity Technologies ISS User s Manual Rev 1 3 Warranty Acuity Technologies Inc makes the following limited w
25. ort the error level at which a soft position or speed error will be reported EL 1 Lower speed error limit EL 2 Lower position error limit EH 1 Higher speed error limit EH 2 Higher position error limit Lower limits must be lt 0 Higher limits gt 0 ER Latched Errors Reports clears errors detected in the current power cycle since the last time ER was cleared In the case of transient errors such as a CAN bus soft error this value will be retained after the error condition has corrected ER 0 will clear the retained errors See EC for list of error bits ES Echo on off A value of 1 turns NSC serial port character echo on default O turns echo off An alternative to local echo at terminal emulator FD Load factory default parameters from PROM Reads the factory servo parameters from non volatile memory and set the active parameters to the retrieved values See also SV and LD HL N LL N Jerk acceleration speed and position limits Positive and negative values for motion limits HL N sets reports the positive limit for each and LL N the negative limit Jerk in encoder counts sec Acceleration in encoder counts sec Speed in encoder counts sec Position in encoder counts ZZZ Z Nol Il AUNE Jerk is defined as the rate of change of acceleration For all except position lower limits must be lt 0 Higher limits gt 0 For position lower limits must be lt 0 Higher limits gt 0 Setting bot
26. presently in effect ID CAN node address Sets reports the CAN address of the servo from 1 to 127 IN Motion command input source Sets Reports motion command input source The serial port remains active for configuration and other commands 1 Serial port 2 Analog Input 3 PWM Input JV Jog at constant velocity Reports last JV commanded or ramps to the specified velocity in encoder counts second and continues until the next motion command is received or a position limit is exceeded Uses the jerk and acceleration limits to reach the commanded velocity JV 0 will stop using these limits To stop immediately and hold position use the ST command See also PV for actual velocity KA Acceleration feedforward gain Applies a motor current proportional to the instantaneous commanded speed in position control in addition to the KF and PID output current This can be used to improve transient response in systems with large inertial loads This parameter only has an effect in PA and PR commands and their binary equivalents KF Velocity feedforward gain Applies a motor current proportional to the commanded speed JV or to the instantaneous speed in position control in addition to the KA and PID output current This can be used to improve transient response in systems with a high degree of mechanical speed proportional damping This parameter only has an effect in JV PA and PR commands and their binary equivalents KP KI KD
27. riptions 3 1 Servos Case Aluminum black anodized Shafts Hardened steel Diameter ISS 6 0 03 mm ISL 10 0 03 mm Gears Steel Sealed output and connectors Position Feedback 5000 count optical quadrature optical encoder on output shafts Index and Home channels Connectors LEMO 1K series Connector characteristics Humidity max lt 95 at 60 deg C 140 F Vibration 15 g 10 Hz 2000 Hz Shock Resistance 100 g 6 ms Salt Spray Corrosion gt 144 hr Climatic Category 50 175 21 Shielding min 95 dB 10 MHz Shielding min 80 dB 1 GHz IP Rating 66 3 1 1 Fault Protection The IS Servos include built in protection against possible fault conditions including e Software error handling e Status reporting for a large number of possible fault conditions e Protection against conditions such as excessive temperature under over voltage loss of commutation signal short circuits between the motor power outputs and between each output and power input return e Recovery from loss of commutation signals and communication errors 3 2 Networked Servos 3 2 1 CAN Servo Connectors The pinout and wire chart for both of the power plugs cables on a networked servo are shown below The connectors are capable of carrying 7 amps on each of the 3 power and 3 ground pins 8 Pin ISS NSC Receptacle OrISMRONT Q Z G Page 8 of 23 Acuity Technologies ISS User s Manual Rev 1 3 Servo CANbus Power Connector Pinout 3 3
28. rting level 3 is set this heartbeat acknowledgement is sent from the NSC to the host after each message This provides assurance that the NSC is functioning properly and receiving servo commands with a minimum of communication overhead The heartbeat consists of the letter N This is acknowledgement that a motion command has been received by the NSC not an indication that the servo has received the command or that motion has been completed This is not the same as an individual servo S heartbeat which is relayed through the NSC from a servo Select Servo SS Select a servo for subsequent configuration and motion control commands Addresses of networked servos must be two characters and must be in the range of 01 to 32 Upon power up the default value of SS in the NSC software is 127 Synchronize Time Page 15 of 23 Acuity Technologies ISS User s Manual Rev 1 3 TS Set all servos time to the specified value synchronized to within 100 microseconds This can be used with the BT command for multi axis synchronized motion UK Universal Kill Motor Command When the NSC receives a UK command it sends MO 0 commands to all CAN servos This command disables power to the motor but the shaft may coast due to inertia US Universal Stop Motion Command When the NSC receives a US command it sends a Stop Motion ST command to all CAN servos The ST command stops immediately and puts it into the position control mode For a detaile
29. s high voltage switches and should not be plugged unplugged with power applied 2 Connect the NSC power cable s flying leads to your system power supply 3 Turn on power The green LED will light when power is applied to the NSC If the power light flashes no servos are detected This is normal when no servos are connected If it blinks when servos are connected it may be due to improper network geometry or missing termination plugs The red LED is normally off If the Red LED flashes there is a servo error The LED will flash the number of times indicating the address 1 to 20 of the servo with a fault pause and repeat If more than one servo has a fault the lower numbered servo will be indicated Transient faults such as momentary position errors may not be indicated but will appear in status messages from the NSC to the host 4 Remove power from the NSC and connect the servos to the NSC through the four 8 pin ports on the NSC front panel with the servo cables supplied Either connector on a servo may be used for connection to an NSC or another servo Page 6 of 23 Acuity Technologies ISS User s Manual Rev 1 3 To Power Controller Termination Typical Daisy Chain Configuration 5 Install the termination plugs e There are 2 pairs of servo connectors on the NSC front panel one above and one below the LEDs If one connector of a pair is used and the other unused the unused connector have a termination plug installed If
30. sececececeesenseaeceeccecsessaaeseecescsessaaeceseceesenenseaeees 7 3 COMPONENT DESCRIPTIONS vsscsssssisctesssssesessscnssssensecsesvsdecssonsssosesonsosssssasecbescsssubassosscduesobendaassisetnessecteaessses 8 3 1 SERVOS ei cet at sie thick T ts ate E en IES 8 3 1 1 No1 cd DOXA 64 11 6 EEE IEEE EE E EEE EAEE EEE EEEE EAE TAEAE 8 3 2 NETWORKED SERVOS 5563 53505205 eed s3 oa vocbeaseepeat ta Boia socd Pave a a SE A 8 3 2 1 CAN Seo O16 1 1 610 ARERR ARCEE EPR EPR EARS EEE PR Er ARE Rr I ee ee eee 8 3 3 STANDALONE RS 232 VOLTAGE INPUT SERVOS cccccccccesssssscesececsesesecesececeeseneceeccecsenessaeseescsesenssaeeeeeens 9 3 3 1 Standalone Servo Connector Locations and PinOuUts cccccccccccccccccccccccscscececscscscscseseseseseseseseseseseseseseseseeess 9 3 3 2 Standalone Servo Analog Voltage Input csccsccsccesccescsesscesscesecesecnsecsecseeeseeeseesseesseseseeseceseseasenaeesaeees 9 5 3 3 Standalone Servo Home INPutl s zicciccssaysscissersecceeessesuptesive stony ios ter eir o eie Dri E apea RSET ESEESE ENE aa 10 3 4 NETWORK SERVO CONTROLLER sars eare e EE R Eear ANa aN eE E R E rear TASIE rRe 10 3 4 1 YAAA A O18 51 0 are AREER Re A N EE EE E N A E AA 10 3 4 2 RYA AOE OUA EA E BE EE ENE E A A A N A 10 3 4 3 Controlling PWM Servs is tienoon soyani a ae i eea EEE E E O VEE RSE E NAREDE EEE a 10 344 Using PWM Input Signal s icsscassteveassscedsenseccaeobgesgpneedeeuseay cots ea oE R E EE a pE E RSE atiii as 10 3 5 ARSA i LONN HE ege
31. sed for high speed control of a servo network from a host control program through the NSC The motor must be enabled MO 1 for this command to have an effect These moves take place at once They are not affected by the BT command This command does not have a specific code Rather the first byte of the command is a binary value specifying the type of motion commanded Valid values are 1 4 A 4 byte parameter must follow The parameter is a 32 bit two s complement value representing the number of encoder counts for absolute or relative position mode the servo speed in encoder counts second for speed mode or the current in milliamps for torque mode First byte binary codes 1 Absolute position 2 Relative position 3 Velocity 4 Torque motor current Replies Servo ack or status according to the servo status reporting control value BT Set the time of execution of the next motion command Starts the next PA PR JV or TC command at the time specified provided the specified time is after the time of receipt of the BT command and the motion command If the command has not begun executing Page 17 of 23 Acuity Technologies ISS User s Manual Rev 1 3 by the time a second motion command is received the pending delayed command is removed Sending BT 0 will remove any pending delayed execution See also TM Note The servo time in milliseconds is a 32 bit value and will wrap around when the time value reaches 2 1 milliseconds Users
32. servo speed in encoder counts second for speed mode or the current in milliamperes for torque mode per the present value of SM for each servo addressed Replies Servo ack or status according to the status reporting value for each servo and the NSC AD NN Set New Servo Address Seeks a servo attached to the CAN network with address NN and changes its address to AA The default address for new servos is 127 As each new servo is added to a network AD 127 AA should be performed to set its address within the range 01 20 before adding another new servo Servos will retain their addresses when moved from one network to another so care must be taken to avoid conflicting addresses Reply The new servo address if it was successfully assigned 0 otherwise AP NN Map PWM Input to Servo Maps PWM input NN to servo AA NN is in the range 1 to 8 and AA in the range 1 to 32 If the servo address is in the range 1 to 20 the 1 to 2 ms input is scaled to the configured position torque or speed limits for that servo If AA is in the range 21 to 32 the corresponding output PWM width and repetition rate will track the input PWM signal with up to 1 ms delay Page 14 of 23 Acuity Technologies ISS User s Manual Rev 1 3 NR Set query NSC status reporting level Set the way NSC status messages are sent to the host This is distinct from the status reporting level for a servo In a network each servo will report status to the NSC in accordance with
33. the NSC looking into the cable plug not the mating NSC connector is shown below Pin Wire Function Pin Wire Function ul Vin White Vin 2 Brown GND 4 2 L2 GND 3 L3 Vin Green Vin 4 Yellow GND Yellow GND Green 60 Amp NSC Plug 20 Amp NSC Plug Page 11 of 23 Acuity Technologies ISS User s Manual Rev 1 3 3 6 Serial and Auxiliary Input Connectors Pinouts are shown below for the SERIAL1 AUX1 and AUX2 connectors SERIAL1 RS 232 model PWM Output Address Map Connector AUX1 AUX1 AUX1 AUX1 AUX2 AUX2 AUX2 AUX2 AUX2 AUX2 AUX2 AUX2 Pin 1 2 3 4 1 2 3 4 5 6 7 8 Servo Address AUX1 Power Pins 10 13 AUX1 Ground Pins 14 17 19 22 AUX2 Power Pins 10 16 AUX2 Ground Pins 17 19 26 Reserved AUX1 pins 9 18 AUX2 pins 9 18 Do not connect PWM Input Address Map Connector AUX1 Pin 5 23 6 24 7 25 8 26 Input Address ONOaRWNDN Tx RX RX Tx SERIAL1 RS 422 model O a o Q s oY wW O a O 10 toj t f va lt h lra lu Sie t 2 t pej ee I I J 2 Q 2 2 O G Ve t j t j tel k fo o war o H a j ee t j t t j 2 ran k 63 Oo o j 109 a T paf ju Jee O _ al gl AUX 1 AUX2 Page 12 of 23 Acuity Technologies ISS User s Manual Rev 1 3 3 6 1 NSC Front Panel LEDs The green LED will light when power is applied to the NSC If the power light flashes no servos are
34. the relative move will be from the target location not the current location which may differ from the target by a holding error The drive moves to the desired target position as fast as possible subject to the jerk speed and acceleration limits See HH and HL commands See also PA Absolute Position PU Power Up Behavior Page 21 of 23 Acuity Technologies ISS User s Manual Rev 1 3 Configures the servo s power up behavior Valid parameters are 0 Do not activate the motor on power up Servo will not engage until a motion or HO command is received Zero position is the encoder position when the servo engages This is the default 1 Activate the motor causing it to hold position but do not move to home on power up 2 Activate the motor and home the servo setting the encoder value to 0 at the home location PV Report Present Velocity Reports the present velocity in encoder counts per second This is an average of the velocity over the previous 10 milliseconds This may be noisy and of low resolution at low speeds PX Report Present Position Reports the present position in encoder counts RS Soft Reset Restarts the servo as if from power up SR Status Reporting Level Set the way servo status messages are sent to the host This is distinct from the status reporting level for the NSC In a network each servo will report status to the NSC in accordance with its settings and the NSC will always relay these messages as
35. ud rate of the CANBus cannot be changed EN Echo on off Set query the NSC character echo mode A parameter value of 1 turns NSC serial port character echo on 0 turns echo off May be turned off if local echo at terminal emulator is on knabbbb nabbbb Move Servos Binary Command Sends a torque speed or position command to one or more servos depending on the servo mode Servo SM command and immediately executes the motion This command is composed of binary values so it cannot be issued from a keyboard It is used for high speed control of a servo network from a host control program through the NSC This command does not have a specific code Rather the first byte of the command is a binary value specifying the number of CAN servos being commanded Valid values are 1 20 This command causes the NSC to issue a TC JV or PA command followed by a BG command to the specified servo s not the servo presently selected with the SS command The second byte and optionally every 5 subsequent byte is a servo address Valid values are 1 20 The four bytes following each address are a position or speed value for that servo depending on the mode of the servo A 4 byte value must follow each address and the number of 5 byte address parameter pairs must match the binary value of the first byte of the command The parameter is a 32 bit two s complement value representing the number of encoder counts for absolute or relative position mode the