Home

User Manual - Advanced HPC

image

Contents

1. 13 1 1 3 Product Physical Specifications and Power 13 42 Features List aan ne in dar fes dant ie iO e ets 15 1 3 InfiniBand FDR and FDR10 Overview 15 Chapter 2 Hardware ci iei dore dac Exe nk ia ile rg 16 2 1 Installation Safety Warnings 16 2 2 Power Supply Redundancy 20 2 2 1 1000W Power Supply Units 20 2 2 2 1600W Power Supply Units 20 2 3 LED Status Indicators uis m IRR a DER edd e ee 22 2 3 1 Power Supply Unit LEDS 22 2 3 2 Leaf Board LED Indicators 24 2 3 8 Spine Board LED Indicators 25 2 3 4 Spine Side Panel Display LED Indicators 27 2 3 5 Management Module LED Indicators 29 2 3 6 Port Connector Interfaces 29 2 4 SBIEEIOW us esu nn Rose ES Ree SS E br pP ae ide 30 2 5 QSFP Cable Power Budget Classification 30 2 6 Management Module Interfaces 30 2 641 One edd Part ace s br Laure dened tad seid Partt d 31 2 6 2 CONSOLE rs Fe e d ed dtd aie vs 31 2 6 3 MGT Management 31 20 MUUSB A nue dr LE 31 2 6 5 Reset AST
2. 41 Figure 19 Inserting the Caged Nuts for the Faceplate 42 Figure 20 Cable Holders rra ee e RR DO CR DER OT ee RE E Se 43 Figure 21 Cable Holder Placement 44 Figure 22 Chassis Rails and Rail Slides 45 Figure 23 Placement of Chassis in Rack 46 Figure 24 Installing the Handles 5 2 205 Kama Anang 233280 BERT een 46 Figure 25 Screw the Handles Onto the Chassis 47 Figure 26 The Rails are Already Connected Onto the Chassis 48 Figure 27 Raising the Chassis Using a Mechanical Lift 49 Figure 28 Put on the Rail Slide rs du a er 49 Figure 29 SX6512 Chassis on the Shelf 50 Figure 30 Face Plate Mounting Bolt Locations 50 Figure 31 Move the Rail Slide to the Vertical Support 51 Figure 32 Ground Connection cue ee ee EE Reni IRE ed os AN EE Kx d eus 52 Figure 33 Multiple Power Inlets Electric Caution Notification 53 FIgure 34 Spine Module errar Rat o NIE Oa n EROR EC RU Qe iod ir 54 Figure 35 Spine Side Panel Display Status Indications 57 Figure 36 Management Module Status Indications for Normal Operation 57 Figure 37 Power Cord Nurmberlng
3. 11 SCL 2 wire serial interface clock 30 9 MS ROS 12 SDA 2 wire serial interface data LPMode ModSelL 13 GND Ground bu END Rx3p Receiver Non Inverted Data 33 1143p Tx4p 14 put 34 Txan Tx4n 35 GND GND 4 15 Rx3n Receiver Inverted Data Outp ETE Txip Dep 3 16 GND Ground ETE Ha M 17 Rxlp Receiver Non Inverted Data put 18 Rxln Receiver Inverted Data Outp 19 GND Ground 20 GND Ground 21 Rx2n Receiver Inverted Data Outp 22 Rx2p Receiver Non Inverted Data put 3 23 GND Ground 24 Rx4n Receiver Inverted Data Outp 25 Rx4p Receiver Non Inverted Data put 3 26 GND Ground 27 ModPrsL Module Present 28 IntL Interrupt 29 Vcc Tx 3 3 V Power supply transm 30 Vccl 43 3 V Power Supply 31 LPMode Low Power Mode 32 GND Ground Tx3n Transmitter Non Inverted Da M ellanox Technologies 83 Rev 1 5 lews QSFP Connector Male and Female Vi Figure 52 Top 18 35 View into Rear of Connector GND AX n 7 TXip GND TX3n TX3p GND LPMode Vcc1 VccTx IntL ModPrsL GND RX4p RX4n GND RX2p RX2n GND Ng N N M GND TX2n TX2p GND TX4n TX4p GND ModSelL ResetL LO VecRx SCL o o ER GND RX3p RX3n GND RX1p RXin GND 0 View into Front of Cage LO 8 ANO 15 diXH ANO UEXH dexu ANO vas 10S XH99A Tieseu TISSPON AND dex UpXL
4. The leafs spines and management modules are shipped separately 5 3 6 2 5 Installing the Shelf 1 Place the ESD mat on the floor where you will be working and put on the ESD strap Make sure the ESD strap is touching your skin and that the other end is connected to a verified ground 2 Clip 4 caged nuts into the holes in the rack you will be using to connect the shelf brackets Check that both sides of the shelf are at the same level in the rack 40 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 Figure 17 Inserting the Caged Nuts for the Shelf Top of shelf a Bottom of shelf AR Do not use this hole 19 3 Using two of the bolts for each rail slide install the rail slides onto the rack Check that both sides of the switch left and right are the same level in the rack Figure 18 Connect Rail Slide to Rack Vertical support 4 Place the four bolts for the caged nuts within reach 5 Put the shelf into place and screw the bolts into the nuts from step 2 6 Extend the rail slides to the rack vertical support and screw them to the rack 7 Tighten all of the screws to 9 2 Nm or 81 5 pound inches 8 Insert 8 caged nuts for the faceplate in the exact locations shown in Figure 19 Inserting the Caged Nuts for the Faceplate Mellanox Technologies 41 co al gg Rev 1 5 Installation Figure 19 Inserting the Caged Nuts for the F
5. 14 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 1 2 Features List e 216 FDR 56Gb s InfiniBand ports in a 9U switch 24 2 Tb s aggregate data switching capacity with ultra low latency IBTA 1 3 and 1 21 compliant SDR DDR QDR FDR10 FDR link speed Congestion control e Adaptive routing e Port mirroring Chassis High Availability sMB High Availability 1 3 InfiniBand FDR and FDR10 Overview The Mellanox SX6512 switch system supports FDR a pre standard InfiniBand data rate where each lane of a 4X port runs a bit rate of 14 0625Gb s with a 64b 66b encoding resulting in an effective bandwidth of 54 54Gb s The FDR physical layer is an IBTA specified physical layer using different block types deskew mechanism and framing rules The SX6512 switch also supports FDR10 a non standard InfiniBand data rate where each lane of a 4X port runs a bit rate of 10 3125Gb s with a 64b 66b encoding resulting in an effective bandwidth of 40Gb s FDR10 supports 20 more bandwidth over regular QDR using the same QSFP cables connectors Both FDR and FDR10 support Forward Error Correction FEC as described in IEEE Std 802 3ap 2007 Amendment to IEEE Std 802 3 2005 chapter 74 FDR and FDR10 are only guaranteed to work with approved Mellanox Cables gt gt d FDR10 is only guaranteed to work with approved Mellanox ConnectX 3 adapters gt 1 Features for a future rele
6. 3 torcida a Ra RR IEEE 59 Figure 38 PSU Locations rs eias Dueb SUR RAM te Pee EN Ed IRE 59 InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 Figure 39 Power Supply Au Gage MX tt ie alt BN an EA eo Mose emt ed 59 Figure 40 Leaf Board Numbering 60 Figure 41 Ejector LAICA 2446 o Rb teeta de PANG mt ebd 61 Figure 42 Leaf Release a id a er ee WR Ae er 61 Figure 43 Management Module Numbering 63 Figure 44 Ejector bateli eos ae ae ae A ne 63 Figure 45 Spine Board Extraction 222 cero ee nie 63 Figure 46 Fan Locations on the Chassis 65 Figure 47 Leaf Fan Module Extraction 65 Figure 48 Spine Fan Module 2 4 r 2422 ra e e CR adeps 66 Figure 49 Fan Status LED on the Spine Module 66 Figure 50 Ejector batch uet ee a 68 Figure 51 Management Module u pd ee 22 Rex e RR oe a 68 Figure 52 QSFP Connector Male and Female Views 84 Rev 1 5 List of Tables Table 1 Revision History of this User s Manual 9 Table 2 Reference Documents and Web Sites 9 Table 3 Switch Rack Mechanical and Environmental Requirements 13 Table 4 OPNs for Power Supply Units 21 Table 5 Leat Status LE
7. M 14 UL und CSA Certified Netzkabel F r Nordamerika Stromanschluss w hlen Sie ein Netzkabel das UL und CSA Certi fied LA 3 Leiter 18 AWG mit einem angespritztem Stecker bewertet bei 125 V 15 mit einer Mindestl nge von 1 5 m Six Feet aber nicht mehr als 4 5 m F r die europ ischen Zusammenhang w hlen Sie ein Netzkabel das international harmonisiert und der Aufschrift lt HAR gt 3 Leiter mindestens 0 75 mm2 Draht bewertet mit 300 V mit einem PVC Mantel isoliert Das Kabel muss eine angespritztem Stecker bewertet bei 250 V 10 A 15 Ableitstrom gt 3 5mA LEAKAGE gt 3 5mA WARNUNG Hohe Ableitstrom Earth Verbindung bevor Sie die Verbindung von wesentlicher Bedeutung werden 16 Add GND Verbindung Informationen Bevor Sie dieses Ger t an das Stromnetz die Schutzerde Terminal Schrauben dieses Ger t muss an den Schutzleiter in der Geb udeinstallation 17 Installation Codes Dieses Ger t muss installiert sein entsprechend auf die neueste Version des Landes National Electrical Code F r Nordamerika m ssen in bereinstimmung mit den gel YN tenden Vorschriften in der US amerikanischen National Electrical Code und dem Canadian Electrical Code 18 Zusammenschaltung von EINHEITEN Kabel f r den Anschluss an das Ger t RS232 und Ethernet Schnittstellen m ssen UL zertifiziert Typ DP 1 oder DP 2 Hinweis wenn nicht mit Wohnsitz in LPS Schal LA tung berstromschutz Eine leicht zug
8. Disconnect all power supplies to ensure a powered down state inside of the switch plat form gt gt 9 Montage et entretien sur baie Lorsque ce produit est mont ou entretenu sur baie il faut prendre des pr cautions sp ciales pour s assurer que le syst me reste stable En g n ral il faut remplir la baie avec du mat riel de bas en haut 10 Fuite gt 3 5mA Leakage gt 3 5mA ATTENTION La connexion la terre des forts courants de fuite est essentielle avant le branchement de l alimentation Avant de brancher l appareil la conduite d alimentation les vis de protection la terre du terminal de l appareil doivent tre appliqu es l installation de protection la Terre du b timent 11 Forts Courants de Fuite High Leakage Current Attention Forts courants de fuite Il est essentiel de relier a la terre avant de brancher l alimentation 12 Ajouter une information de connexion la masse Connect a Valid Ground to this Device Avant de brancher l appareil la conduite d alimentation les vis de protection la terre du terminal de l appareil doivent tre appliqu es l installation de protection la Terre du b timent 13 Installation du mat riel Ce mat riel ne doit tre install remplac ou entretenu que par du personnel form et qualifi 14 Elimination du mat riel L limination de ce mat riel doit s effectuer dans le respect de toutes les l
9. ANO dzXL uZXL ANO Mellanox Technologies 84 InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 Appendix F Replacement Parts Ordering Numbers M Table 17 Replacement Parts Ordering Numbers Part Description OPN Power supply unit PSU 1000W for Modular Switch MTPO05001 Family Power Supply unit PSU 1600W for Modular Switch MTP006002 Family Power supply blank MTM005001 Leaf board unit 18 port FDR MSX6001FR Leaf board unit 18 port FDR 10 MSX6001TR Modular Switch Family Leaf Blank MTM005004 Spine board unit for FDR system MSX6002FLR Spine board unit for FDR10 QDR system MSX6002TBR Spine board blank MTM005002 PPC460 Management Module MSX6000MAR x86 Management Module MSX6000MBR Modular Switch Family Management Blank MTM005003 Rack Installation Kit for IS5600 SX6536 Series MTR005600 Cable Management Device Set for IS5600 SX6536 8 MTR005601 Cables Set For IS5600 SX6536 Series MTR005602 IS5600 SX6536 IS5300 SX6518 Series Modular MTF005001 Switch leaf cooling chassis fan unit located on Leaf Side 155600 5X6536 IS5300 SX6518 Modular Switch 83 MTF005002 leaf cooling chassis fan unit located on Spine Side SX6536 SX6518 MSX6512 MSX 6506 Modular MTF005005 Switch Series Spine Fan Unit DB to RJ45 Harness HAR000028 Power cord 250V 15A 2 0M C14 to C13 ACC000334 Power cord 125V 15A 2 0M C14 TO C13 ACC000242 Power cor
10. amp SS GE LE 50 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 Figure 31 Move the Rail Slide to the Vertical Support a Y N or cs f A a N 10 Place the 4 holed spacer on the outside of the vertical support and screw in the 4 screws for each rail slide Use the split lock washers here 11 Remove the two handles from the spine side and save all four handles for future use 12 Ground the switch 13 Replace all of the spines power supply units fan units and management modules removed at the start of the installation procedure 14 Plug in the power cables 15 Check the Status LEDs and confirm that all of the LEDs show status lights consistent with normal operation Warning Any yellow status LEDs is cause for concern and must be dealt with imme diately LA It can take up to 5 minutes to boot up during which time the status LED may indicate flashing green 16 You can start connecting all of the cables to the switch 3 65 Ground Connections Make sure to connect the ground post to a valid electrical ground Use a grounding lug and a ground wire of sufficient capacity to safely convey a potential discharge A ground wire of AWG 6 or 4mm diameter is recommended for grounding this device The chassis 1s concurrently grounded through each of the PSUs Only connect the PSU cords to prop erly grounded outlets Do not rely on the PSU grounds It is absolu
11. include 2 Fans Power Con sumption Leaf Max Heat Out put Power Con sumption for Active cables QSFP Typical 91W not including QSFP power Max 94W not including QSFP power 10 397 BTUs hr 2 0W MAX Power level 2 Speed protocol Management Data Rate QoS Safety EMC Emissions Environmental Vibration Acoustic Shock and Vibration InfiniBand Data Rate Safety Environmental Acoustic Protocol Support Management Auto Negotiation of 56Gb s 40Gb s 20Gb s 10Gb s QoS 56Gb s per port Regulatory Compliance EMC US Canada cTUVus certificate Emissions International CB report and certificate Russia GOST R certificate Argentina S mark certificate DoC BSMI certificate for the power supply only Vibration EU IEC 60068 2 64 Random 76 DbA Shock and ISO 7779 Vibration ETS 300 753 Managed using MLNX OS Baseboard Performance and Device management Agents for full InfiniBand In Band Manage ment 8 InfiniBand Virtual Lanes for all ports CE EMC amp safety report and cer tificate USA FCC part 15 class A Canada ICES 003 class A Australia New Zealand AS NZS CISPR 22 class A Japan VCCI Class A Australia C Tick certificate EU IEC 60068 2 29 Shocks Type I II EU IEC 60068 2 32 Fall Test ETSI EN 300 019 2 2 1999 09 78 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1
12. sisse eie ba ec aee an an de a ARR IR Rue dd 31 Chapter 3 Installation vacio oi on antenne 33 3 1 Environmental and Safety Recommendations 33 3 2 Chassis Package Contents 34 3 3 Leaf Package Contents 35 3 4 Spine Package Contents 35 3 5 Management Package Contents 35 3 6 Physical Installation pa cer 9 RR RR RR RR RES 35 3 6 1 ESD Connection 36 3 6 2 Installation Procedure 36 3 6 3 Installing the Cable Holder 42 Rev 1 5 3 6 4 Installing the Chassis 45 3 6 5 Ground Connections 51 3 7 Power G nnections essor er 52 3 7 1 Powering Up the Switch Platform 52 3 8 InfiniBand QSFP Cable Installation 54 3 8 1 Supported Approved Cables 55 3 8 2 Cable Power Classes 55 Chapter 4 Chassis Power Up 56 4 1 Power Supply and Spine Board Indicator Status at Power ON 56 Chapter 5 Insertion and or Hot swap Extraction 58 5 1 Power Supply UNITS x4 osten ars rn er en 58 5
13. 19 482 6mmp Connector side Chassis Insufficient room for recommended bending radius Doors You will most likely need extra room for cable bending on the connector side of the chassis and should plan to keep the spine side as close to the rack door as possible thus having more room for the cables See Figure 1 on page 46 1 Screw the handles onto the chassis Use the 8 allen head screws and the allen wrench pro vided Two handles go on the connector side and two go on the sides of the chassis Use the locknuts on the spine side of the chassis to secure the handles There may be extra nuts left over Figure 24 Installing the Handles There may be extra nuts left over Don t worry 2 46 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 Figure 25 Screw the Handles Onto the Chassis Handles Do not use the handles on the fans for lifting or moving the chassis in the rack y MEN p D y L Di DK 4 D u Fan 2 Fan 3 Fan sx6512 alala ajalalalala DODDDDUDE pasa 000000900 alala ee eee DODDDDUDE pasna 000000900 paaa DDDDDDODH fafafafafalalalala 900000900 Mellanox Technologies 47 Wo TO VEREINE Rev 1 5 Installation Figure 26 The Rails are Already Connected Onto the Chassis lt 40 lbs 40 70 lbs 70 121 lbs gt 121 lbs lt 18 kgs 18 32 kgs 32 55 k
14. 5 Scalability and Performance Leafs Power Supplies Up to 12 leafs 18 ports each 4 Power Supplies standard Spines 6 spine boards Management All spines are needed for non Modules 2 available 1 required for opera blocking configuration tion Switching Addressing Leaf fans 4 none 48K Unicast Addresses Max per era Subnet 16K Multicast Addresses per Subnet Switching Switching Capacity 24 2 Tb s Performance Simultaneous wire speed any port to any port A 1 EMI Certification EMI certification on the fully populated chassis was performed with the chassis installed in a closed two door rack using the chassis installation kit supplied by Mellanox Tech nologies A 2 Approved Cables For a list of all approved cables see http www mellanox com related docs user_manuals Mellanox_approved_cables pdf A 3 EMC Certifications The list of approved certifications per chassis in different regions of the world is located on the Mellanox Website at http www mellanox com related docs user_manuals Regulatory and Compliance Guide pdf EMC Statements are also in the Regulatory and Compliance Guide Mellanox Technologies 79 o ap ng Rev 1 5 Appendix B Thermal Threshold Definitions There are three thermal threshold definitions for the SwitchX switch device which impact the overall switch system operation state Warning Critical and Emergency 1 Warning 100 C On managed systems
15. Environmental Requirements Rack Rack of leafs Ambient Height Rack Width Weight Max Power 216 x QSFP Ports A Depth S Temp Required of Spines 10 U 19 25 7 12 6 120 kg 265 LBS Typical 2553 59W including Max 45 C 444mm EIA 310 685 mm Full configuration QSFP at 2W Min 0 C including 482 6 mm Typical 2337 59W including bottom 48 kg 105 LBS QSFP at 1W shelf Empty configuration Max 2815 11W including QSFP at 2W 83 94 kg 185 LBS Up to 4 Power Supplies of 100 Shipped configura 240VAC 50 60Hz 6 3 13A tion The switch ships in a minimum base configuration plus additional modules depending on the chosen customer configuration Optional modules included Leaf boards Management modules Spine boards Figure 3 shows the connector and spine sides fully populated ellanox Technologies SR A Rev 1 5 Overview Figure 3 SX6512 Switch Views xj E EN sj gU COA gen EHER XI mo gt m coc cock EGER E an a i BUE p gee S ECC Bb Spine Side a fili E Up to 4 power supply units AA llano m L L IX TU Mi oo oS EE 1 Fan 2 Fan 3 Fan 4 SX6512 6 spine modules B es EEE l EEE JI ee O00000000 PS2 oooonannn 4 leaf fan modules HH enter Jalal alala ocooooo8 0 0 0 uh 12 leaf modules 000000000 goooooooo DOG Dooonaone 2 management modules
16. KG 105 LBS empty configuration 83 94kg 185 LBS shipped configuration The switch platform uses 10U of rack pace in a standard 19 rack 9U for the chassis and 1U for the shelf The switch ships from the factory with mounting holes on the spine side There are upper brackets to connect the leaf side to the rack near the top of the chas sis The weight of the switch is supported from underneath the unit by the shelf Rev 1 5 Installation This chassis can be installed in standard 19 racks that have between 65cm and 80cm between the vertical supports of the rack Make sure that a fully populated rack including cables will have sufficient air flow for cooling Choose a rack which is able to support the mechanical and environmental characteris tics of a fully populated switch chassis bo 3 6 1 ESD Connection Before starting any procedure on the SX6512 switch system 1 Put an ESD prevention wrist strap on your wrist and make sure there is good contact between your body and the strap 2 Plug the other end of the wrist strap to a valid ground Make sure that this is a tight fit 3 6 2 Installation Procedure 3 6 2 1 Requirements You will need 2 phillips screwdriver 3 phillips screwdriver a grounding lug ground wire to properly ground the chassis Y The installation will be much easier with a power screwdriver v It is recommended to use AWG6 or 4mm diameter wire for grounding purposes It is recommended t
17. for Power Supply Units PSU E OPN Wattage Description MTPO05001 1000 W Supplies N22 redundancy for SX6536 and SX6518 chassis Supplies N 1 redundancy for SX6512 and SX6506 chassis MTP006002 1600W Supplies N N redundancy for all switch chassis at 220 Volts 21 Rev 1 5 Hardware 2 3 LED Status Indicators The LEDs are placed on the chassis for the convenience of the IT manager All chassis conditions and management options are available and controllable through the management SW either CLI or Web GUI Y It is recommended that all of the chassis sub systems be maintained and managed through the management software 2 3 1 Power Supply Unit LEDs Each Power Supply Unit has the following indicator LEDs Figure 4 Power Supply Unit Status Indications DC AC OK FAIL oK AC When lit this LED indicates input voltage between 100 and 240 Volts DC FAIL When lit this LED indicates a fault in the power supply DC OK When lit this LED indicates that the output from the power supply is 48 VDC gt The PSUs are on the spine side of the chassis behind two cover panels The plugs for these PSUs are on the leaf side of the chassis y 22 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 Figure 5 PSU Cover On and Off PSU Covers a CDO OO Hani 1 Fan 2 Fan 3 Fan ta SX6512 Beam Sononnnna N Ooo
18. gislations et r glementations nationales en vigueur 88 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 15 Codes lectriques locaux et nationaux Ce mat riel doit tre install dans le respect des codes lectriques locaux et nationaux 16 Codes d installation L appareil doit tre install selon l ancienne version des codes lectriques nationaux du pays Pour l Am rique du Nord l quipement doit tre install conform ment aux sp cifications du Code Electrique National Am ricain et du Code Electrique Canadien 17 Interconnexion des unites Les c bles de branchement l unit RS232 et les interfaces Ethernet doivent tre certi fi s UL de type DP 1 ou DP 2 Note lorsqu il existe dans un circuit non LPS Protection contre la surintensit Un appareil de protection r pertori facilement accessible contre la surintensit du circuit de branchement et calibr 20A doit tre incorpor dans le c blage lectrique du b timent 18 Exposition au rayonnement grave Mise en garde l utilisation de commandes ou de r glages ou l ex cution de proc dures autres que ce qui est sp cifi dans les pr sentes peut engendrer une exposition au rayonnement grave PRODUIT LASER DE CLASSE 1 et r f rences aux normes laser les plus r centes CEI 60 825 1 1993 A1 1997 A2 2001 et NE 60825 1 1994 A1 1996 A2 2001 19 S assurer que les encei
19. it will be necessary to reboot the chassis once the defective PSU has been replaced With 1600W optional PSU supplies the chassis can run on as little as 1 2 of the full complement of PSUs N N allows the chassis to run on 2PSUs supplied from one power grid while 2 are con nected to a second power grid 1 Check all FRUs for proper insertion and seating before connecting the AC power cords e Boards e Power supplies Leaf fan modules Spine fan modules 2 Insert all leafs that you plan to use in the chassis Start at the bottom of the chassis and work your way up Insert the first two spines in the top two slots Insert the rest of the spines from the bottom of the chassis up to slot 3 Insert thermal blanks in unused leaf slots to maintain balanced air flow Tighten all leaf and spine mounting screws Connect the power cords to the PSUs 3 4 5 6 7 8 Connect the power cords to grounded electrical outlets With N 1 PSU redundancy do not power up the chassis with less than all PSUs installed 4 1 Power Supply and Spine Board Indicator Status at Power ON It can take up to 5 minutes to boot up the system Turn off the system if any LEDs remain red for more than 5 minutes 56 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 As the power is turned on you should observe the following conditions for normal oper ation 1 Power Supply Unit s AC OK and DC OK indicators are O
20. modules 3 15 Total This total is in kilograms Multiply the total by 2 2 to get the total weight in pounds Mellanox Technologies 81 EE a Rev 1 5 Appendix D Calculating the Power of a Chassis To calculate the power consumption of a chassis take the base power and add the power of the fans spines management modules and leafs Table 15 Power Consumption of Chassis Parts Part Typ Power Passive Cables Typ Bayan er canker IB FDR leaf 91W 125 Spine 108W Not applicable Fan 117W Not applicable Management Module 14W Not applicable 82 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 Appendix E QSFP Interface Table 16 InfiniBand QSFP Connector Pinc Connector Connecto Pin r Pin Signal Description Number Name 1 GND Ground 2 Tx2n Transmitter Inverted Data In J3 and J6 3 Tx2p Transmitter Non Inverted Da Input 19 2 GND O 4 GND Ground 21 Rx2n Rxtn 18 22 Ax2p Bon 17 5 Tx4n Transmitter Inverted Data Inj 23 GND anp 16 6 Tx4p Transmitter Non Inverted Da 24 us Ed 15 Input nx xan TO 25 Rx4p Rx3p 14 7 GND Ground 26 en GND 3 8 ModSelL Module Select 27 ModPrsL SDA 2 9 ResetL Module Reset nt sah 10 Vcc Rx 3 3 V Power supply receive 2 vot Voc Rx
21. ngliche Auflistung Abzweigleitung berstrom Schutzeinrichtung 20 A bewertet werden m ssen in dem Geb ude Verkabelung 19 Zweipolige bzw Neutralleiter Sicherung im Netzteil Achtung Zweipolige bzw Neutralleiter Sicherung im Netzteil Netzstecker ziehen um sicher zustellen da keine Spannung am Ger t anliegt Entfernen Sie alle Netzkabel vor dem ffnen der Abdeckung dieses Produkts oder dem Ber hren der Innenteile ellanox Technologies 93 Co ap uy Rev 1 5 20 40 lbs 40 70 lbs 70 121 lbs 121 lbs 18 kgs 18 32 kgs 32 55 kgs gt 55 kgs 94 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 Appendix I Advertencias de seguridad para la insta laci n Spanish 1 Instrucciones de instalaci n Antes de conectar el equipo a la fuente de alimentaci n leer todas las instrucciones de instalaci n 2 Lesi n corporal por peso 4 e 40 lbs 40 70 lbs 70 121 lbs gt 121 lbs lt 18 kgs 18 32 kgs 32 55 kgs gt 55 kgs 3 Lesi n corporal por peso Y N This equipment is very heavy and should be moved using a mechanical lift to avoid injuries 4 Sobrecalentamiento i No se debe utilizar el equipo en un rea con una temperatura ambiente superior a la obs m xima recomendada 45 C Adem s para garantizar una circulaci n de aire adec Y N uada se debe dejar como m nimo un espacio de 8 cm 3 pulgadas alrededor de las aberturas
22. nog PS2 alalalalalaala aaa DDBDOCBODO 000000000 lalalalala aa 000000000 000000000 apoa Googoogo0 PSU Covers co oe LUE Ex ES TT ISX6512 manana lalalalala HEBR sans HEBR Gants Daanan lalalalala aa 000000000 000000000 Daanan lalalalala Mellanox Technologies 23 KN E Rev 1 5 Hardware 2 3 2 Leaf Board LED Indicators Figure 6 Leaf Board Led Indicators YO Lae NA Y SAEZ t 2 3 2 1 Status LED Each leaf board has a Status LED on the far left of the leaf Table 5 shows the leaf status accord ing to the LED condition The Leaf Status indicator LED A has the following LED assignment Table 5 Leaf Status LED LED Condition LED Description Off No power to the Leaf Solid Green Leaf is up and running Flashing Green Leaf is powering up Solid Orange Non fatal error this leaf needs troubleshooting but does not require chassis shutdown Solid Red Fatal error 2 3 2 2 Bad Port LED EN The Bad Port indicator is located on the left side of the leaf The following Bad Port conditions are possible Table 6 Bad Port LED Configurations LED Configuration Description Off OK all ports are up and running Flashing Orange Error one or possibly more ports has just received a symbol error This LED shows symbol errors Possible causes for this are e bad cable e bad connection e bad c
23. only When the SwitchX device crosses the 100 C threshold a Warning Threshold message will be issued by the MLNX OS management SW indicating to system administration that the switch has crossed the Warning threshold Note that this temperature threshold does not require nor lead to any action by hardware such as switch shutdown 2 Critical 120 C When the SwitchX device crosses this temperature the firmware will automatically shut down the device 3 Emergency 130 C In case the firmware fails to shut down the SwitchX device upon crossing the Critical thresh old the SwitchX device will auto shutdown upon crossing the Emergency 130 C threshold 80 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 Appendix C Calculating the Weight of a Customized Chassis The weight of a customized chassis can be calculated for any possible customization as follows Take the weight of a chassis with the following FRUs installed e All fans modules e All power supplies The weight of the SX6512 chassis configured above is kg To this add the weight of installed FRUs e Spines e Leafs e Leaf blanks e Management modules Fill in the table below to calculate the weight of your system Number of FRUs FRU Type Weight of 1 FRU Total Weight FRU Type Chassis as shipped of Spines 3 77 of leafs 2 76 of leaf blanks 764 of management
24. such as a telecommunication centre or a dedicated computer room 18 Installation codes This device must be installed according to the latest version of the country national electrical codes For North America equipment must be installed in accordance to the applicable requirements in the US National Electrical Code and the Canadian Electri cal Code 19 Interconnection of units Cables for connecting to the unit RS232 and Ethernet Interfaces must be UL certified type DP 1 or DP 2 Note when residing in non LPS circuit LA Overcurrent Protection A readily accessible Listed branch circuit overcurrent protec tive device rated 20 A must be incorporated in the building wiring 18 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 20 Hazardous Radiation Exposure Caution Use of controls or adjustment or performance of procedures other than those specified herein may result in hazardous radiation exposure CLASS 1 LASER PRODUCT and reference to the most recent laser standards IEC 60825 1 2007 03 and EN 60825 1 2007 21 Do Not Use the Switch as a Shelf or Work Space Caution Slide rail mounted equipment is not to be used as a shelf or a work space E 22 WEEE Directive According to the WEEE Directive 2002 96 EC all waste electrical and electronic equipment EEE should be collected separately and not disposed of with regular household waste Dispose of this product and all of it
25. the chassis must go through an initial configuration proce dure See the Installation Guide for the initial configuration procedure 2 5 6 Switch Shut Down Procedures To shut down the chassis run the following command twice once for each MM Reload halt noconfirm f The chassis cannot be restarted remotely To restart the chassis you must physically go to the switch and unplug all of the power cords to the chassis and then replug in all of the power cords to the chas sis The first time you run the command it shuts down the master management module and the second time shuts down the slave management module To shut down a leaf run the following command no power enable lt module gt To shut down a spine run the following command no power enable lt module gt To shut down a management module run the following command no power enable lt module gt 69 Rev 1 5 Disassembly and Disposal 6 Disassembly and Disposal 6 1 Disassembling the Chassis Power down the chassis Remove all power cables Remove all connector cables Disconnect the ground lug from the ground post Remove all leafs Remove all spines AL ON Une des oue pae IS Remove all management modules Use enough people to safely lift this product de 40 lbs 40 70 lbs 70 121 lbs gt 121 lbs lt 18 kgs 18 32 kgs 32 55 kgs gt 55 kgs This product and all of its parts are NOT to be disposed of with household waste This pr
26. y respetuosa con el medio ambiente Mellanox Technologies 97
27. 000000000 OO00000d0 aafaa aa alata 000000000 ujuja a a ajajala OO00000000 Coooooooo 3 On the spine side of the chassis remove the cover to the power supply unit for the non working PSU Odd numbered PSUs are on the left side and even numbered PSUs are on the right side facing the spines There are four phillips head screws for the cover plate Figure 39 Power Supply Handle Latch m 5 9 gt dm QA 4 Grasping the handle with one hand push the black latch release while pulling the handle outward As the PSU unseats the PSU status indicators will turn off Mellanox Technologies 59 QA A Rev 1 5 Insertion and or Hot swap Extraction 5 Remove the PSU To insert a PSU 1 Make sure the mating connector of the new unit is free of any dirt and or obstacles 2 Insert the PSU by sliding it into the opening until a slight resistance is felt 3 Continue pressing the PSU until it seats completely The latch will snap into place confirming the proper installation 4 Insert the power cord into the supply connector on the other side of the chassis Eb Replace the cover over the PSUs The green indicators should light If not extract the PSU and re insert it again 5 2 Leaf Boards Do NOT mix replacement parts based on different generations of chip Do not install InfiniScale IV based replacement parts within a SwitchX based chassis and vice versa All Replacement modules must be consisten
28. 1 1 Extracting and Inserting the Power Supply Unit 58 3 2 Leaf Boards 2 8 pa kad pami S rn Seded bai vest 60 5 2 1 Extracting a Leaf Board 60 5 2 2 Inserting a Leaf Board 61 5 3 Spine Bords are ia wot Ota mo Date gate E eene 62 5 3 1 Extracting a Spine Board 62 5 3 2 Inserting a Spine Board 64 bat Fan Modules ua Sene X toot a inten ae PONE ae e DR RENE a ee 64 5 4 1 Leaf Fan Module 65 5 4 2 Spine Fan Modules 66 5 5 Management Module oss er endow xx RR xS 67 5 5 1 Extracting a Management Module 67 5 5 2 Inserting a Management Module 68 5 6 Switch Shut Down Procedures 69 Chapter 6 Disassembly and Disposal 70 6 1 Disassembling the Chassis 70 6 1 1 Removing the Chassis 70 6 1 2 Removing the Bottom Shelf 70 6 2 Disposaliz aodio Oe Sine de Ra gee yee wa Pps aye E UEM 71 Chapter 7 Switch Management Tools 72 7 1 InfiniBand Subnet Manager 73 7 2 Fabric Inspector Diagnostic
29. 4X The speed and link The switch does not provide a visual means to indicate the port speed configuration width configurations can be retrieved using management software 5 Spine Board LED Indicators Each leaf board is connected by links to each spine module Each spine has the following LEDs One status LED for the spine health One status LED for the spine fan modules e 36 status LEDs showing the existence of the leaf to spine connection e One Bad Port Led showing symbol errors in the data stream e One UID LED that can be lit to identify an individual spine The 36 LEDs on each spine are divided by the number of leafs and the result N is the number of connections from each leaf that are connected to the spine 6 spines must be installed and working to ensure that full BW exists between nodes The maximum num ber of connections from each leaf is 3 If the number of leafs x the maximum number of connections per leaf is less than 36 then some of the leaf to spine connection LEDs may be OFF ellanox Technologies 25 Rev 1 5 Hardware The status LEDs for the spine and their descriptions are shown in Table 8 The LEDs indicate as follows Figure 7 Spine Status LEDs Spine Status Fan Status Bad Port UID LENS IU 000000000 BEEBE el HEBEN ELLE ALLE a Spine Leaf IB Connection Status 2 3 3 1 Status LED A Table 8 shows the spine status according to the LED conditio
30. Bad Port LED Configurations LED Condition Description Off OK No ports have received symbol errors recently Flashing Orange Error One or possibly more ports has just received a symbol error This LED shows symbol errors Possible causes for this are e bad cable e bad connection e bad connector This LED lights up when one or more ports is receiving a symbol error The LED imme diately goes off until the next symbol error is received 2 3 3 5 UID LED Switch Identifier The UID LED is a debug feature that will become available to customers in the near future For details please contact Mellanox Technologies support 2 3 4 Spine Side Panel Display LED Indicators The spine side panel display has LEDs that show the chassis condition Mellanox Technologies 27 CET TO o MN Rev 1 5 Hardware Figure 8 Spine Side Panel Display Status Indications AA CE O STATUS PSU SPINE LEAF MNG 1 MNG 2 STATUS FANS FANS STATUS STATUS Table 12 LEDs Display for Normal Operation n T Normal LED Condition Description State STATUS Off No Power Green Green System is up and running Yellow System warning Attention needed such as overheating Red System not operational Diagnostics fail CPU hang HW fail Overheat critical Blinking green System booting Restore factory defaults in progress PSU STATUS Off No power Green Green Normal operational Red PS faul
31. D ua TE 24 Table 6 Bad Port LED Configurations mpa wa en A YQ ERG 24 Table 7 Connector Physical and Logical Link Indications 25 Table 8 Spine Status LED ot tha VAR ee 26 Table 9 Spine Fan Status LED ruca ae Ee EE Rea 26 Table 10 Spine to Leaf IB Link Status 27 Table 11 Bad Port LED Configurations 43 Sees x ra 27 Table 12 LEDs Display for Normal Operation 28 Table 13 LEDs Display for Normal Operation 29 Table 14 Switch Specification Sheet SX6512 4N R 77 Table 15 Power Consumption of Chassis Parts 82 Table 16 InfiniBand QSFP Connector Pinout 83 Table 17 Replacement Parts Ordering Numbers 85 InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 Revision History Table 1 Revision History of this User s Manual Revision Date Details 1 5 October Added Warning for handles 2012 1 4 September Added figure 23 2012 Added information regarding inserting the bottom spine first Insert spines from bottom to top 1 3 August Minor changes due to changes in container 2012 1 2 July 2012 Fixed broken link 1 1 July 2012 Added figure to show use of 2nd type of mechanical lift Added EMI explanation to Appendix Added explanation to N 2
32. Diagnostics fail CPU hang HW fail Overheat critical Blinking green System booting Restore factory defaults in progress PSU STATUS Off No power Green Green Normal operational Red PS fault detected User should check individual power sup plies for fault indications SPINE FANS Off No power to fan Green STATUS Green Nominal operational Red One or more of the spine fans is bad User should check individual spine fan LEDs for fault indications LEAF FANS Off No power to fan Green STATUS Green Nominal operational Red One or more of the leaf fans is bad User should check individual leaf fan LEDs for fault indications MASTER Off this management module is not the master MM Green Green Management module is operating as a master 1 e the other management module is a slave 2 3 6 Port Connector Interfaces The connector side of the switch has 12 leaf boards and each leaf board has 18 QSFP ports The ports on each leaf board are placed in two rows 9 ports to a row The ports are labelled as shown in Figure 10 The bottom row ports are flipped from the top row See Figure 11 Rev 1 5 Hardware Figure 10 Port Numbering 1 3 5 7 9 11 13 ARA AAA A O RO O Y E A ATA A EE SATA MEA ee 2 4 6 8 10 12 14 16 18 Figure 11 Top and Bottom Ports E u 2 4 Air Flow These switches come with the air flow pattern of air entering through the spine side and exiting through
33. EDs Leaf connection LEDs 3 8 InfiniBand QSFP Cable Installation The switch uses industry standard QSFP InfiniBand cables which are available from Mellanox Technologies The Mellanox proprietary QSFP cables support full 56 56Gb s FDR 40 40Gb s FDR10 40 40Gb s QDR 20 20Gb s DDR and 10 10Gb s SDR bidirectional wire speed of the switch ports All InfiniBand QSFP connections are made to the leaf boards Each leaf has 18 InfiniBand QSFP connectors in two rows which are numbered 1 18 See Section 2 3 6 for port numbering If maximum cable lengths are exceeded data transfer will be reduced and the bit error rate will increase FDR BandWidth is supported only by MLNX QSFP cables FDR and FDR10 are only guaranteed to work with approved Mellanox Cables EN AN EN All cables can be inserted or removed with the unit powered on To insert a cable press the con nector onto the port receptacle until the connector is firmly seated The orange LED indicator above the port will light when the physical connection is established when both ends of the cable are properly connected to working devices Allow 15 seconds for link to get up To remove dis engage the lock and slowly pull the connector away from the port receptacle For a valid physical connection both ends of the cable must be connected to working devices Take care to not impede the air flow through the ventilation holes next to the Infini Band ports Use cable lengths which
34. FP Modular InfiniBand Switch Plat form known in this document as the chassis or switch and its operational environment Mellanox SX6512 switch systems provide the highest performing fabric solution by delivering high bandwidth and low latency to Enterprise Data Centers EDC High Performance Comput ing HPC and Embedded environments Networks built with the SX6512 system can carry con verged traffic with the combination of assured bandwidth and granular quality of service Built with Mellanox s 5t generation SwitchX VPI switch device SX6512 systems provide up to 56Gb s full bidirectional bandwidth per port With up to 216 ports in a 9U high form factor these systems are among the densest switching systems available The switch platform comes pre installed with all necessary firmware for standard operation within an InfiniBand fabric and requires an InfiniBand compliant Subnet Manager running from one of the hosts or the management module of the switch system An initial configuration proce dure should be followed to initialize the switch before connecting it to the network after which normal operation can proceed See the installation guide for details regarding the initial configu ration Once connected to the network the Subnet Management software automatically discov ers and configures the fabric and begins utilizing the switch The Mellanox Operating System MLNX OSTM software package provides a subnet manager and network mana
35. Guide available through MLNX OS with explanations and examples MLNX OS Software Configuration Configuration Guide for MLNX OS displaying different configuration Guide scenarios Conventions Throughout this manual the name SX6512 and the terms chassis and switch are used to describe the 216 port QSFP InfiniBand chassis unless explicitly indicated otherwise The following icons are used throughout this document to indicate information that is important to the user Y This symbol makes recommendations to the user This symbol indicates information that is helpful to the user This symbol indicates a situation that can potentially cause damage to hardware or software Warning This symbol indicates a situation that can potentially cause personal injury and or damage to hardware or software 10 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 Mellanox Part Numbering Legend Place Field Decoder M Mellanox Technologies SX System Type SwitchX Switch PR Data Transfer Protocol 1 2 3 4 Ethernet 5 6 7 8 InfiniBand G Module Generation 5 6 7 8 FF Number of leafs 36 18 12 06 Separator P Power Supplies N N N redundant 0 0 1 1 2 2 R Chip Generation R SwitchX S SwitchX 2 Mellanox Technologies 11 Rev 1 5 Overview 1 1 1 12 Mellanox Technologies Overview This User Manual provides an overview of the SX6512 QS
36. Mellanox TECHNOLOGIES 216 Port InfiniBand FDR Switch Platform Hardware User Manual PN MSX6512 4R MSX6512 NR Rev 1 5 www mellanox com Rev 1 5 NOTE THIS HARDWARE SOFTWARE OR TEST SUITE PRODUCT PRODUCT S AND ITS RELATED DOCUMENTATION ARE PROVIDED BY MELLANOX TECHNOLOGIES AS IS WITH ALL FAULTS OF ANY KIND AND SOLELY FOR THE PURPOSE OF AIDING THE CUSTOMER IN TESTING APPLICATIONS THAT USE THE PRODUCTS IN DESIGNATED SOLUTIONS THE CUSTOMER S MANUFACTURING TEST ENVIRONMENT HAS NOT MET THE STANDARDS SET BY MELLANOX TECHNOLOGIES TO FULLY QUALIFY THE PRODUCTO S AND OR THE SYSTEM USING IT THEREFORE MELLANOX TECHNOLOGIES CANNOT AND DOES NOT GUARANTEE OR WARRANT THAT THE PRODUCTS WILL OPERATE WITH THE HIGHEST QUALITY ANY EXPRESS OR IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT ARE DISCLAIMED IN NO EVENT SHALL MELLANOX BE LIABLE TO CUSTOMER OR ANY THIRD PARTIES FOR ANY DIRECT INDIRECT SPECIAL EXEMPLARY OR CONSEQUENTIAL DAMAGES OF ANY KIND INCLUDING BUT NOT LIMITED TO PAYMENT FOR PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES LOSS OF USE DATA OR PROFITS OR BUSINESS INTERRUPTION HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY WHETHER IN CONTRACT STRICT LIABILITY OR TORT INCLUDING NEGLIGENCE OR OTHERWISE ARISING IN ANY WAY FROM THE USE OF THE PRODUCT S AND RELATED DOCUMENTATION EVEN IF ADVISED OF THE POSSIBILITY
37. N and FAIL indicators are OFF 2 There is a green Status LED per spine board per leaf board and per management module that indicates power supplies are good 3 Spine Board indicators will display status of internal links to the installed leaf boards All PHY links to existing leaf Boards should be ON 4 Check the Spine LEDs and make sure they coincide with Figure 35 Figure 35 Spine Side Panel Display Status Indications EOL LE AAA O STATUS PSU SPINE LEAF MNG 1 MNG 2 STATUS FANS FANS STATUS STATUS 5 Check the Management Module LEDs and make sure they coincide with Figure 36 Figure 36 Management Module Status Indications for Normal Operation Een CI Mellanox Technologies 57 QA Rev 1 5 Insertion and or Hot swap Extraction 5 Insertion and or Hot swap Extraction Before starting any procedure on the SX6512 switch system put an ESD prevention wrist strap on your wrist and connect to the SX6512 chassis Do NOT mix replacement parts based on different generations of chip gt Do not install InfiniScale IV based replacement parts within a SwitchX based chassis and vice versa All Replacement modules must be consistent with the Chassis family be and switch chip generation When hot swapping any of the units it is necessary to wait 1 minute after removing the defective part before inserting the new part This is necessary so that the manage ment module will start a new cycle checking through the leafs a
38. OF SUCH DAMAGE Mellanox TECHNOLOGIES Mellanox Technologies Mellanox Technologies Ltd 350 Oakmead Parkway Suite 100 Beit Mellanox Sunnyvale CA 94085 PO Box 586 Yokneam 20692 U S A Israel www mellanox com www mellanox com Tel 408 970 3400 Tel 972 0 74 723 7200 Fax 408 970 3403 Fax 972 0 4 959 3245 Copyright 2012 Mellanox Technologies All Rights Reserved Mellanox Mellanox logo BridgeX ConnectX CORE Direct InfiniBridge InfiniHost InfiniScale PhyX SwitchX Virtual Protocol Interconnect and Voltaire are registered trademarks of Mellanox Technologies Ltd Connect IB FabricIT MLNX OSTM ScalableHPC Unbreakable Link UFMTM and Unified Fabric Manager are trademarks of Mellanox Technologies Ltd All other trademarks are property of their respective owners 2 Mellanox Technologies Document Number 3835 InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 Table of Contents Revision History ons us tnc e ares a AA 9 About this Manual 24 2 a eee ee da 9 Intended Audience 9 Related Documentation 9 GOHVBHIIOHS a ridad Ba Ng 10 Mellanox Part Numbering Legend 11 Chapter 1 Overview rer 12 1 1 Product Information ccc ees 12 1 1 1 Serial Number and Product Version Information 12 1 1 2 Management Module MAC
39. Power Numbers 1 0 May 2012 Initial release About this Manual This manual provides an overview of the SwitchX based SX6512 modular InfiniBand chassis switch and guidelines for its operation Intended Audience This manual is intended for users and system administrators responsible for installing and setting up the chassis platform The manual assumes familiarity with the InfiniBand architecture specification Related Documentation The documentation set accompanying the QSFP Chassis InfiniBand Switch platform includes the following Table 2 Reference Documents and Web Sites Document Name Description InfiniBand Architecture Specifica The InfiniBand Architecture Specification that is provided by IBTA tion Vol 1 Release 1 2 1 Switch Hardware Errata For any possible errata due to hardware issues see the switch support product page This requires a customer support login M ellanox Technologies 9 Rev 1 5 Table 2 Reference Documents and Web Sites Document Name Description Mellanox MLNX OS SwitchX WebUI Overview for MLNX OS software Software WebUI User s Manual Mellanox MLNX OS SwitchX This document contains information regarding configuring and manag Software User Manual ing Mellanox Technologies SwitchX Switch Platforms MLNX OS Software Command Ref Command Reference Guide for MLNX OS listing all of the commands erence
40. aceplate Place the caged nuts here 3 6 3 Installing the Cable Holder Y Now is the time to install the cable holder 42 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 Figure 20 Cable Holders Right side cable holder E 12 X M6 caged nut Ili 12 X M6 bolt for caged nut 1 Place the Cable holder next to the rack on the connector side of the chassis and iden tify the holes where the caged nuts are to be placed The cable holders should go to the outside of the vertical supports Bo 2 Set the bottom of the cable holder at the level of the shelf Ah If the cable holder is not set properly the upper bracket will not line up with the cable holder Mellanox Technologies 43 Rev 1 5 Installation Figure 21 Cable Holder Placement Notch for upper bracket washer Set this even with the top of the shel 3 Screw the cable holder onto the rack using the screws provided 4 Repeat steps 1 3 for the second cable holder 44 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 3 6 4 Installing the Chassis Figure 22 Chassis Rails and Rail Slides Rail Slide 8u tz bd 00000000 Do not use the handles on the fans for lifting or moving the chassis in the rack Rev 1 5 Installation Figure 23 Placement of Chassis in Rack Doors RACK Cable with recommended bending radius
41. al Rev 1 5 3 Push the fan module as far as it will go make sure the locking latches engage If the Fan LED continues to show red remove the fan module and check the pins on the connector inside if the spine to make sure that none of them are bent 5 5 Management Module When hot swapping any of the units it is necessary to wait 1 minute after removing the defective part before inserting the new part This is necessary so that the manage ment module will start a new cycle checking through the leafs and spines for the FW versions Before starting any procedure on the SX6512 series switch system put an ESD preven tion wrist strap on your wrist and connect to the SX6512 series chassis 5 5 1 Extracting a Management Module Management modules are located on the leaf side above the leafs There are two places to install the management modules Only one management module is required to run the switch system aa Each management module has a pair of ejectors that lock the board in place and serve as a lever for seating or extracting see Figure 51 1 Run the shut down command no power enable lt module gt For example to shut down management module 2 run the command below switch 1 Orca648 master config no power enable MGMT2 Disconnect all cables connected to the management module Push outward on the latches to unlock the ejectors from the chassis Open the ejectors until they are 45 degrees from the mo
42. allow routing horizontally around to the side of the chassis before bending upward or downward in the rack 54 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 3 8 1 Supported Approved Cables For a list of approved cables for this switch see the Mellanox approved cable list http www mellanox com related docs user manuals Mellanox approved cables pdf 3 8 2 Cable Power Classes Chassis and switches need to be able to dissipate the heat generated by high power I O cables and modules The Mellanox SX 65XX series chassis are rated for cables up to class 2 as per the SFF committee classification SFF 8436 PDF See http www mellanox com content pages php pg cables for the cable class rating of Mellanox cables Rev 1 5 Chassis Power Up 4 Chassis Power Up Before starting any procedure on the SX6512 system put an ESD prevention wrist strap on your wrist and connect to the SX6512 chassis With N 1 PSU redundancy the chassis must be started with a full complement of possible PSUs thereafter it can run on one less than the total number of PSUs This final PSU is redundant and allows for hot swapping a PSU should one fail Connecting the PSUs to different AC lines pro vides AC failover protection The system should continue to run and allow a hot swap of a defective PSU Should there not be enough power to keep all of the leafs running MLNX OS may power down some leafs If this happens
43. ase Mellanox Technologies 15 Co ap ng Rev 1 5 Hardware 2 Hardware 2 1 Installation Safety Warnings These safety warnings are in English For French Spanish and German see the Appendixes 1 Installation Instructions LA Read all installation instructions before connecting the equipment to the power source 2 Bodily Injury Due to Weight h Use enough people to safely lift this product 40 lbs 40 70 lbs 70 121 lbs 121 lbs 18 kgs 18 32 kgs 32 55 kgs gt 55 kgs 3 Installation in Restricted Access Location LA This unit is intended for installation in a Restricted Access Location 4 Over temperature ing the maximum recommended 45 C 113 F Moreover to guarantee proper air This equipment should not be operated in an area with an ambient temperature exceed A flow allow at least 8cm 3 inches of clearance around the ventilation openings 5 Stacking the Chassis The chassis should not be stacked on any other equipment If the chassis falls it can cause bodily injury and equipment damage 6 Redundant Power Supply Connection Electrical Hazard power supply do not operate the product with the blank cover removed or not securely This product includes a redundant power or a blank in its place In case of a blank A fastened 16 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 7 Multiple Power Inlets Risk of electric shock and energy hazard T
44. ce defective spine fan modules as soon as they are identified 8 4 Spine Board The yellow LED on the Spine board is lit 1 Check the MLNX OS management for confirmation and possible explanation of the alert 2 Make sure that there is nothing blocking the front or rear of the chassis and that the fan mod ules and ventilation holes are not blocked especially dust over the holes 3 If you find dust blocking the holes it is recommended to clean the fan unit and remove the dust from the front and rear panels of the switch using a vacuum cleaner 4 Remove and reinstall the spine board Make sure the mating connectors of the unit is free of any dirt and or obstacles See Section 5 3 on page 62 5 Make sure that the spine and the Leafs both have the same version of FW 6 Reburn the FW and remove and reinstall the spine 7 Replace the spine board 8 5 MLNX OSTM Software For more detailed instructions concerning MLNX OS software see the Mellanox MLNX OS SwitchX Software WebUI User s Manual or the Mellanox MLNX OS SwitchX Software User Manual 76 Mellanox Technologies Appendix A Specification Data Specification Data Sheet Table 14 Switch Specification Sheet SX6512 4N R InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 Physical Size Mounting Weight Center of Gravity Size Weight Max Air Flow 15 75 x 19 x 27 inches 400 mm x 482 6mm x 733 mm The
45. d Type B for USA Canada Mexico Taiwan ACC000204 Power cord Type H for Israel ACC000205 Power cord Type E F for Sweden France Germany ACC000207 Netherlands Russia ellanox Technologies Co OT NA 85 Rev 1 5 Table 17 Replacement Parts Ordering Numbers Continued Part Description OPN Power cord Type G for UK ACC000208 Power cord Type D for India ACC000209 Power cord Type I for China ACC000210 Power cord Type J for Switzerland ACC000211 Power cord Type B for Japan ACC000212 Power cord Type I for Australia ACC000213 86 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 Appendix G Avertissements de s curit d installation French 1 Instructions d installation Lisez toutes les instructions d installation avant de brancher le mat riel la source d alimentation lectrique 2 Temp rature excessive Ce mat riel ne doit pas fonctionner dans une zone avec une temp rature ambiante d passant le maximum recommand de 45 C 113 F Un flux d air de 200LFM cette temp rature ambiante maximale est n cessaire En outre pour garantir un bon coulement de l air laissez au moins 8 cm 3 pouces d espace libre autour des ouver tures de ventilation 3 Empilage du ch ssis Le ch ssis ne doit pas tre empil sur un autre mat riel Si le ch ssis tombe il peut pro voquer des blessures corporelles et des d gradati
46. de ventilaci n 5 Apilamiento del chasis A Los chasis no se deben apilar sobre otros equipos La ca da del chasis podr a causar lesiones corporales as como da os al equipo 6 Dos fusibles uno en el polo y otro en el neutro A N Dos fusibles uno en el polo y otro en el neutro Quitar los cables de corriente antes de abrir la tapa de este producto o tocar cualquier componente interno TN Rev 1 5 7 Cuando hay rayos peligro de descarga el ctrica No utilizar el equipo ni conectar o desconectar cables durante per odos de actividad de rayos 8 Conexi n y desconexi n del cable Copper InfiniBand A Dado que los cables de cobre InfiniBand son pesados y no son flexibles su conexi n a los conectores y su desconexi n se deben efectuar con mucho cuidado Para ver adver tencias o instrucciones especiales consultar al fabricante del cable 9 Montaje y mantenimiento de bastidores Al instalar o realizar el mantenimiento de este aparato en un bastidor es preciso adop Mo tar precauciones especiales para garantizar que el sistema se mantenga estable En gen i N eral en un bastidor los equipos se deben instalar comenzando desde abajo hacia arriba 10 Instalaci n de equipos N La instalaci n el reemplazo y el mantenimiento de este equipo estar n a cargo nica A mente de personal capacitado y competente 11 Asegurar confinamientos adecuados un confinamiento adecuado para componentes el c
47. dule AR D Pull out on the module using both ejectors Mellanox Technologies 67 Co ap ng Rev 1 5 Insertion and or Hot swap Extraction Figure 50 Ejector Latch Pull the module out of the chassis Management Module Spine Management Module Spine Push the latch m release 0 PP The board is short therefore do not let go of it while sliding it out Figure 51 Management Module I I2C CONSOLE MGT A amp RST PSU S Fans L Fans Master zz ee 00 0 IA Ejectors 5 5 2 Inserting a Management Module 1 Start with the latch fully open that is 45 degrees to the front panel of the leaf 2 Carefully seat the management module into the slot and slowly slide the board into the chas sis until the ejectors begin to engage on the chassis edge 3 Press the ejectors inward until the locks snap This indicates that the board is fully seated 4 Perform the initial configuration on the management module See the Installation Guide the master management module CPU and only then configure the slave By default the master CPU is the top management module For further information on the master and be slave roles see the MLNX OSTM Software UM section High Availability P On switch systems with dual management systems first connect the cable and configure 68 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 09 All management modules in
48. e installation site building be equipped with a light ning rod Itis highly recommended that the installation site be equipped with smoke detectors and a fire alarm warning system SSA 8 Mellanox Technologies 33 Rev 1 5 Installation Y The system requires a KVA rated UPS system It is recommended that a UPS system be installed to protect the equipment in the event of unexpected power failure Make sure that the outlets and circuits will not be overloaded Spread out the load over at least two or three circuits or use a 3 phase circuit 3 2 Chassis Package Contents The package includes e 1 box containing installation kit parts cable management system power cords e 1 shelf e 1 chassis with the following modules installed e 4fans e 4PSUs If you are not using a mechanical lift to install the chassis reduce the weight of the chassis by removing all of the power supply units and fan units and put aside for reinstallation after the chassis is installed in the rack Installation Guide e 1 chassis e 1 box containing various other parts Inside the single box is 3 smaller boxes e 1 installation kit box 1 box containing 4 power cords 250v 15a 2 0M C14 to C13 USA UL Standard e 1 cable management kit Before you install your new SX6512 series chassis unpack the system and check to make sure that all the parts have been sent check this against the parts list Check the parts for visible dam age t
49. eakage gt 3 5mA For North American power connection select a power supply cord that is UL Listed and CSA Certified 3 conductor 16 AWG terminated with a molded plug rated at LA 125 V 13 A with a minimum length of 1 5m six feet but no longer than 4 5m For European connection select a power supply cord that is internationally harmonized and marked lt HAR gt 3 conductor minimum 1 0 mm wire rated at 300 V with a PVC insulated jacket The cord must have a molded plug rated at 250 V 10 A 16 High Leakage Current LA Warning High leakage current Earth connection essential before connecting supply 17 Add GND connection information Before connecting this device to the power line the protective earth terminal screws of this device must be connected to the protective earth in the building installation LA GND Connection Information The building installation shall provide a means for a connection to protective earth and the equipment shall be permanently connected to that by a service person A SERVICE PERSON shall check whether or not the socket outlet from which the equipment is to be powered provides a connection to the building protective earth If not the SERVICE PERSON shall arrange for the installation of a PROTECTIVE EARTHING CONDUCTOR from the separate protective earthing terminal to the pro tective earth wire in the building The equipment shall be installed in area where equi potential bonding exists
50. en Temperatur von 45 C 113 F betrieben werden Es ist ein Luft LA strom von 200 LFM bei maximaler Umgebungstemperatur erforderlich Au erdem sollten mindestens 8 cm 3 in Freiraum um die Bel ftungs ffnungen sein um einen einwandfreien Luftstrom zu gew hrleisten 3 Stapeln des Chassis Das Chassis sollte nicht auf andere Ger te gestapelt werden Wenn das Chassis herun terf llt kann es zu Verletzungen und Besch digungen an Ger ten f hren 4 Redundanter Stromversorgungsanschluss Elektrische Gefahr Stromversorgung Betreiben Sie das Produkt nicht wenn diese Abdeckung nicht sicher Dieses Produkt verf gt ber eine Abdeckung ber dem Bereich f r die redundante A festsitzt oder entfernt wurde 5 Bei Gewitter Elektrische Gefahr Arbeiten Sie w hrend eines Gewitters und Blitzschlag nicht am Ger t schlie en Sie keine Kabel an oder ab 6 Anschlie en Trennen von InfiniBand Kupferkabel an die Anschl sse angebracht bzw davon getrennt werden Lesen Sie die speziellen InfiniBand Kupferkabel sind schwer und nicht flexible Deshalb m ssen sie vorsichtig A Warnungen und Anleitungen des Kabelherstellers 7 Gafahr des elektrischen Schocks frei Um alle Einhieten spannungsfrei zu machen sind die Netzstecker aller Netzteile zu Gafahr des elektrischen Schocks Entferrnen des Netzsteckers elnes Netzteils spannungs A entfernen Mellanox Technologies 91 AA Rev 1 5 9 2 Risk of electric shoc
51. ent Module Spine Figure 45 Spine Board Extraction Pull the latches to remove the spine 4 000000000 AS aj mm EEEE EEHEHE HELE INH EE 5555000000 LING E BEER ooo gug EEE If you need to hot swap spine 1 or spine 2 Mellanox Technologies 63 Rev 1 5 Insertion and or Hot swap Extraction 1 Check to see if the spine you need to remove is connected to the master management module See Figure 43 Warning If you have only one management module the chassis will crash 2 Push outward on the latches to unlock the ejectors from the chassis 3 Open the ejectors until they are 45 degrees from the module 4 Pull out on the module using both ejectors 5 3 1 2 Extracting Spine Boards Except 1 or 2 1 Run the shut down command no power enable lt module gt For example to shut down spine 06 run the command below switch 1 Orca648 master config no power enable S06 2 Push outward on the latches to unlock the ejectors from the chassis 3 Open the ejectors until they are 45 degrees from the module 4 Pull out on the module using both ejectors 5 3 2 Inserting a Spine Board 1 Start with the latches fully open that is 45 degrees to the front panel of the leaf 2 Hold the spine board by the sides with both latches fully open 3 Insert the board into its rail The board should slide in without resistance 4 Push the board in until the hooks on t
52. et de danger energy hazard Entferrnen des Netzsteckers e lectriques Le de branchment The PSUs are all independent elnes Netzteils spannungsfrei d une seule alimentation stabi Um alle Einhieten spannungsfrei lise e ne de branch uniquement Disconnect all power supplies to zu machen sind die Netzstecker qu un module Alimentation ensure a powered down state aller Netzteile zu entfernen Stabilise e Pour isoler com inside of the switch platform pletement le module en cause Il faut de brancher toutes les ali mentations stabilise es 3 Check the Status LEDs on all of the management modules and confirm that all of the LEDs show status lights consistent with normal operation Any yellow or red status LEDs on any of the management modules is cause for con cern and must be dealt with immediately 4 Check that none of the LEDs on the spines are yellow It can take up to 5 minutes to boot up the system Turn off the system if any LEDs remain red for more than 5 minutes 5 Check that the Leaf status LEDs Fan status LED and Spine status LED in the spines are all green The maximum number of connections from each leaf is 3If the number of leafs x the maximum number of connections per leaf is less than 36 then some of the leaf to spine connection LEDs may be OFF Mellanox Technologies 53 Co ap mg Rev 1 5 Installation Figure 34 Spine Module Status Fan Bad Port and UID L
53. formaci n de conexi n a tierra La instalaci n del edificio deber prover un medio para la conexi n con la puesta a tierra de protecci n y un t cnico de servicio deber conectar permanentemente el equipo a dicho medio de conexi n Un T CNICO DE SERVICIO comprobar si la toma el ctrica de la que se suminis trar corriente al equipo provee una conexi n con la puesta a tierra de protecci n del edificio De no ser as el T CNICO DE SERVICIO se encargar de instalar un CON DUCTOR DE CONEXI N A TIERRA DE PROTECCI N del terminal de puesta a tierra de protecci n separado al conductor de tierra de protecci n del edificio El equipo se instalar en un rea donde haya conexi n equipotencial como por ejemplo un centro de telecomunicaciones o una sala de computadoras dedicada 16 C digos de instalaci n Este dispositivo se debe instalar conforme a la versi n m s reciente de los c digos el ctricos nacionales del pa s en cuesti n En Am rica del Norte el equipo se debe instalar de acuerdo con las disposiciones vigentes del C digo El ctrico Nacional de los EE UU y del C digo El ctrico de Canad 17 Directiva sobre RAEE Conforme a la Directiva 2002 96 CE sobre RAEE todos los residuos de equipos el c tricos y electr nicos EEE se deben recolectar por separado y no se deben eliminar junto con residuos dom sticos Al deshacerse de este producto y de todas sus partes h galo de una manera respon a sable
54. gement tools as well as connectivity software for servers and storage and is available on the Mellanox web site Basic installation is covered in Chapter 3 Installation on page 33 Hot swapping components and hardware maintenance is covered in Chapter 5 Insertion and or Hot swap Extraction on page 58 Product Information Serial Number and Product Version Information The serial number GUID Identifier and product version information are found on the label that is attached to the pull out tab that is below the Mellanox logo on the spine side of the chassis Figure 1 Generic Product Label S N MT0806X01504 UNO Y P N MSX6512 4R UA KANAN am GUID 0002 9020027051 LIU TEIL PS MAC 020040 0002C9 DARAN DAN M ade in Israel The GUID is the System Image GUID according to the IB spec It is burned on the board which is in the chassis All the boards and the management software look for this GUID in addition to their own Node GUID InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 1 1 2 Management Module MAC A ee Here is the tab with the product label e Fan 4 SX6512 Each management module has a label with its MAC address See below for the location of this label Figure 2 Management Module MAC Address Location WI a at mx a SER MEN il m m MAC address location IT 1 1 3 Product Physical Specifications and Power Table 3 Switch Rack Mechanical and
55. go of it while sliding it out Figure 42 Leaf Release Push here to release the latch Pull the ejector to remove the leaf Y O dE W AV W p WW 4 5 2 2 Inserting a Leaf Board Start with the latch fully open that is 45 degrees to the front panel of the leaf Carefully set the leaf board into the side guide rails and slowly slide the board into the chassis Catch the hooks onto the vertical bar and push the latch shut Rev 1 5 Insertion and or Hot swap Extraction 5 3 Spine Boards Do not install InfiniScale IV based replacement parts within a SwitchX based chassis and vice versa All Replacement modules must be consistent with the Chassis family P Do NOT mix replacement parts based on different generations of chip and switch chip generation When hot swapping any of the units it is necessary to wait 1 minute after removing the defective part before inserting the new part This is necessary so that the manage ment module will start a new cycle checking through the leafs and spines for the FW versions Each spine has a pair of ejectors that lock the board in place and serve as levers for seating or extracting see Figure 44 Management board 1 is connected to spine board 1 and management board 2 is connected to spine board 2 When a slave management board is not installed or not working the spine board connected to the master management board cannot be
56. gs gt 55 kgs 2 Lift the chassis and slide it onto the shelf Use a mechanical lift or enough people to safely lift the chassis A full chassis weighs 120 kgs an empty chassis weighs 50 kgs y N Do not use the handles on the fans for lifting or moving the chassis in the rack Km 48 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 Figure 27 Raising the Chassis Using a Mechanical Lift y LI A 0 00 O 3 3 Remove the two handles from the sides of the chassis 4 Push the chassis into the rack until the faceplate is 20cm 8 from the vertical support 5 Put the rail slides onto the rails Figure 28 Put on the Rail Slide Mellanox Technologies 49 Rev 1 5 Installation 6 Slide the chassis further into the rack 7 Slide the chassis all the way into the rack until the faceplate is touching the vertical rack sup port The caged nuts placed in the last procedure should line up with the holes in the face plate 8 Screw the 8 screws through the faceplate and into the caged nuts 9 Slide the rail slides to the vertical rails Figure 29 SX6512 Chassis on the Shelf Figure 30 Face Plate Mounting Bolt Locations Fan 3 Holes in the faceplate for mounting on the rack LCL EX Li E amp So e
57. hat may have occurred during shipping gt d If anything is damaged or missing contact your customer representative immediately 5 34 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 3 3 3 4 3 5 3 6 The rack mounting holes conform to the E A 310 standard for 19 inch racks Guaran tee proper ventilation by leaving 8cm 3 of space to the front and rear of the switch This will ensure proper air flow through the chassis This is crucial for maintaining good airflow at ambient temperature In particular route cables such that they do not impede the air into or out of the chassis Leaf Package Contents The leafs are ordered by the customer and are shipped 4 to a box The customer will receive as many boxes as needed to fill the order Spine Package Contents The spines are shipped 3 to a box The customer will receive as many boxes as needed to fill the chassis with a full complement of spines Insert the bottom spine board first Management Package Contents The package includes all of the management modules ordered by the customer e 1 RJA5 to DB9 harness for each management module received Physical Installation Warning This equipment is very heavy Safety is the first concern Make sure that adequate manpower and proper equipment is used for transporting and moving the LA chassis The fully loaded chassis weighs 120 kg 265 LBS full configuration 48
58. he PSUs are all independent Disconnect all power supplies to ensure a powered down state inside of the switch platform 8 During Lightning Electrical Hazard During periods of lightning activity do not work on the equipment or connect or dis connect cables gt 9 Copper InfiniBand Cable Connecting Disconnecting Copper InfiniBand cables are heavy and not flexible as such they should be carefully attached to or detached from the connectors Refer to the cable manufacturer for spe cial warnings instructions gt 10 Rack Mounting and Servicing When this product is mounted or serviced in a rack special precautions must be taken to ensure that the system remains stable In general you should fill the rack with equip ment starting from the bottom to the top gt 11 Equipment Installation This equipment should be installed replaced and or serviced only by trained and qual ified personnel 12 Proper Enclosure A suitable electrical mechanical and fire enclosure shall be provided by the end prod uct manufacturer and or the end user gt 13 Equipment Disposal Disposal of this equipment should be in accordance to all national laws and regula tions Mellanox Technologies 17 Rev 1 5 Hardware 14 Local and National Electrical Codes This equipment should be installed in compliance with local and national electrical codes 15 UL Listed and CSA Certified Power Supply Cord L
59. he latches are touching the vertical bar 3 Now press both latches inward simultaneously You should feel the latches are hooked into the front panel 6 Press both latches applying some force to close them completely The locking latch will engage 5 4 Fan Modules There are four fan modules on the chassis for the leafs They are located on the spine side along the top of the chassis When a fan module is not functioning the status LED on the fan will light up Fach spine has an individual fan module that contains two individual fans Should a single fan fail the Fan Status LED on the spine and the S Fan LED on the management module will light indicating the necessity to replace the fan module Air flow through the spines is independent of the air flow through the leafs 64 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 Figure 46 Fan Locations on the Chassis E Fans oo m L D L Fan 3 El Fan 1 lalalala alla enfers aaa aa aal inae aaa alaa aa aala 5 4 1 Leaf Fan Module There are 4 Leaf fan modules found on the Spine side 5 4 1 1 Extracting the Leaf Fan Module 1 Push and hold the blue latch release See Figure 47 2 Slowly pull out the fan module using the handle Figure 47 Leaf Fan Module Extraction Handle Latch 5 4 1 2 Inserting the Leaf Fan Module 1 Make sure the fan module is oriented correctly top side up Confirm that the
60. hinweise German 91 Appendix I Advertencias de seguridad para la instalaci n Spanish 95 Mellanox Technologies 5 BA E o Rev 1 5 List of Figures Figure 1 Generic Product Label 12 Figure 2 Management Module MAC Address Location 13 Figure 3 9X6512 Switch VIEWS s 22 D SEE ER sra e 14 Figure 4 Power Supply Unit Status Indications 22 Figure 5 PSU Cover On and Off nase Tr REESE 23 Figure 6 Lear Board Led Indicators io dure me a i E RR e be 24 Figute 7 pire Status LEDS 24 25 tat gees sama RO ice Nox Er puce tod ec ine ts 26 Figure 8 Spine Side Panel Display Status Indications 28 Figure 9 Management Module Status Indications 29 Figure TO Port Numbering Semen a ies Ne TG 30 Figure 11 Top and Bottom Ports ouf o nep E ERE PU ADAN DAA DEAD rene 30 Figure 12 Management Module Interfaces 30 Figure 13 Reset Button xc exero er RE bea he gue cades 32 Figure 14 Shelf Installation Kit Parts 37 Figure 15 Chassis Installation Parts orita ERR in 38 Figure 16 Shock and Tilt Stickers 5222222 tia er bene a a 39 Figure 17 Inserting the Caged Nuts for the Shelf 41 Figure 18 Connect Rail Slide to Rack Vertical support
61. hot swapped All of the spine boards can be hot swapped when two management boards installed and working When more than one spine slot is empty always insert the lowest spine board first then Work your way up M2 L 5 3 1 Extracting a Spine Board When a slave management board is not installed or not working hot swapping the spine board connected to the master management board will cause the chassis to crash Neither the CLI nor the GUI management tools will allow you to shut down spine 1 or spine 2 as the management modules are connected to the chassis components through these spines 5 3 1 1 Extracting Spine Board 1 or 2 Spine board 1 is connected to management board 1 and spine board 2 is connected to man agement board 2 62 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 Push the latch release Figure 43 Management Module Numbering MNGI management module 1 MNG2 management module 2 bottom Removing spine 1 causes management module 1 to reset Removing spine 2 causes management module 2 to reset Warning If the spine you want to hot swap is connected to the master management module the management module will reboot when you take out the spine If you have only one management module the chassis will crash Figure 44 Ejector Latch Pull the module out of the chassis Management Module Spine Managem
62. ies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 3 Installation This chassis can be installed in standard 19 racks that have depths between 65cm and 80cm between the vertical supports of the rack 5 Installation and initialization of the chassis is a simple process requiring attention to the normal mechanical power and thermal precautions for rack mounted equipment Your chassis comes only with the power supplies and fans pre installed The rest of the open ings are populated with blanks All of the leafs spines and management modules come shipped in a separate package The chassis requires initial configuration to get the chassis and Fabric management up and running through remote management See the Installation Guide that is packed in the box for the instructions to make the initial configuration LII access area can be accessed only through the use of a special tool lock and key or p This unit is intended for installation in a Restricted Access Location A restricted other means of security 5 3 1 Environmental and Safety Recommendations The following are Mellanox recommendations Recommended ambient temperature in the System room is 20 5 C Recommended humidity range is 40 15 without condensing It is highly recommended that the installation sites be as isolated as possible from all sources of radio transmissions and electrical interference It is highly recommended that th
63. ite for detailed instructions for disassembly according to the WEEE Directive M ellanox Technologies 71 Rev 1 5 Switch Management Tools 7 Switch Management Tools This chapter describes the management module and tools available for Out of Band management of the switch system via MLNX OS 4 There are 2 Ethernet ports 1 for each management module that get connected to Ethernet switches These switches must be configured to 10 100M auto negotiation Aa The SX6512 switch comes standard with a management software module for chassis manage ment called Mellanox Operating System MLNX OS MLNX OS is installed on all SwitchX based managed switch systems management modules MLNX OS includes a CLI WebUI SNMP and chassis management features for software and IB management software OpenSM You can get more information via the Mellanox MLNX OS SwitchX Software WebUI User s Manual or the Mellanox MLNX OS SwitchX Software User Manual The managed switch system includes the following software components Embedded Subnet Manager SM Chassis manager and system BIST SNMP agent 3rd party tool integration GUI Remote logging e SSH telnet e Secured access in band and out band e IPv4 IPv6 network stack The chassis manager will give the user access to Switch temperatures Power supply voltages Fan unit information Power unit information Flash memory Monitoring of e AC power to the PSUs DC powe
64. k and energy hazard The PSUs are all independent Disconnect all power supplies to ensure a powered down state inside of the switch plat form 8 Rack Montage und Wartung sichtsma nahmen zu ergreifen um die Stabilit t des Systems zu gew hrleisten Im Wenn dieses Produkt in einem Rack montiert oder gewartet wird sind besondere Vor A Allgemeinen sollten Sie das Gestell von unten nach oben mit Ger ten f llen 9 Ger teinstallation Diese Ger t sollte nur von geschultem und qualifiziertem Personal installiert ausge tauscht oder gewartet werden 10 Ger teentsorgung Die Entsorgung dieses Ger ts sollte unter Beachtung aller nationalen Gesetze Bestim mungen erfolgen 11 Regionale und nationale elektrische Bestimmungen Dieses Ger t sollte unter Beachtung der regionalen und nationalen elektrischen Bestimmungen installiert werden 12 Richtigen Schutz sicherstellen Geeigneter elekrischer mechanischer und Feuerschutz sind vom Hersteller des Endprodukts oder dem Endbenutzer bereitzustellen 13 Strahlenkontakt Achtung Nutzung von Steuerungen oder Einstellungen oder Ausf hrung von Proze duren die hier nicht spezifiziert sind kann zu gef hrlichem Strahlenkontakt f hren Klasse 1 Laserprodukt und Referenzen zu den aktuellsten Lasterstandards ICE 60 825 1 1993 A1 1997 A2 2001 und EN 60825 1 1994 A1 1996 A2 2001 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5
65. ll allow for N N redundancy This requires a second power grid supplied by a e backup power supply grid gener ator e battery backup system any combination of the above Connecting 2 power supplies to one power supply grid and the remaining 2 power supplies to a sec ondary power supply grid will create N N redundancy This is High Availability Under these condi tions should a power supply fail an electric company power failure or blackout for example power grid High Availability will continue to keep the chassis running at full capacity through the secondary or backup power supply grid With N N optional PSU grid redundancy the chassis can run on 1 2 of the full complement of PSUs N N allows the chassis to run on 2 PSUs supplied from one power grid while 2 are con nected to a second power grid AA With power grid A charged with current and power grid B not charged there is only grid redundancy and not PSU redundancy 5 MLNX OSTM may power down some leafs If this happens it may be necessary to reboot the chassis once the defective PSU has been replaced Two simple ways to reboot is to use the reboot command in the CLI or reboot through the Web GUI 20 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 The form is identical between the 1600W and the 1000W PSUs The standard PSU weighs 0 3kg more than the 1600W PSU N N redundancy ONLY works with a supply voltage of 220V Table 4 OPNs
66. location of the connector in the chassis will line up with the connector in the fan module Mellanox Technologies 65 Rev 1 5 Insertion and or Hot swap Extraction 2 Slowly slide in the new leaf fan module A If the fan module stops before it goes in all of the way it is inserted incorrectly or it 4 1 may be for the other side of the chassis DL A 3 Push the fan module until the latch engages 4 Make sure that the green leaf LED on the module comes on indicating that fan is running 5 4 2 Spine Fan Modules Each spine module has a fan module with two individual fans built in When a fan module is not functioning the Fan Status LED on the spine will light up Figure 48 Spine Fan Module bb n b t E E OOOODODOC maana TU EE yg ae ale Fan Module When a fan module is removed the indicator light will reset Figure 49 Fan Status LED on the Spine Module Ji ey SL 0000 LEE alala a ajajela 10 12 14 16 18 Fan Status 5 4 2 1 Extracting the Spine Fan Module 1 Push the two blue latch buttons together while pulling the fan module out 5 4 2 2 Inserting the Spine Fan Module 1 Make sure the fan module is oriented correctly top side up Confirm that the location of the connector in the chassis will line up with the connector in the fan module 2 Slowly slide in the new spine fan module 66 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manu
67. n Table 8 Spine Status LED LED Condition LED Description Off No power to the spine Solid Green Spine is up and running Flashing Green Spine is powering up Solid Orange Non fatal error this spine needs troubleshooting but does not require chassis shutdown Solid Red Fatal error 2 3 3 2 Fan LED The spine fan indicator LED has the following LED assignment Table 9 Spine Fan Status LED LED Color LED Description Solid Green Spine Fan is OK Solid Yellow One or more of the fans in this spine is not working Each spine has two fans in the fan module 26 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 2 3 3 3 Spine to Leaf IB Connection Status LEDs The leaf connection status on each spine displays the condition of the connection between the spine and each leaf There is a minimum of one LED per leaf per spine and a maximum of 3 LEDs per leaf These LEDs indicate a valid connection between a leaf and a spine Table 10 shows the leaf to spine status according to the LED condition Table 10 Spine to Leaf IB Link Status LED Condition LED Description Off Link is down Solid Green Logical connection Flashing Green Data activity Solid Orange Physical connection 2 3 3 4 Bad Port LED E The Bad Port indicator is located on the left side of the spine The following Bad Port conditions are possible Table 11
68. nd spines for the FW versions This switch platform supports hot swap capabilities for the parts listed below e Power supply units Leaf boards e Spine boards Leaf fan module Spine fan module Management modules 5 1 Power Supply Units The 1000 W power supplies deliver 1000W at 48V The input to each of these power supplies requires 1214 46W at 220V in order to output 1000W For N 1 configuration PSUs Power Supply Unit can be extracted without bringing down the system For N N configuration up to half of the PSUs can go down and the system will continue to run The power required to run the switch system is equally divided between all of the working PSUs 5 1 4 Extracting and Inserting the Power Supply Unit With all of the 1000W power supplies installed the system is in N 1 redundant configuration With all of the N N 1600W power supplies installed the system is in N N redundant configura tion half of the PSUs may be extracted without bringing down the system To extract a PSU 1 Determine which AC connector on the connector side of the chassis corresponds to the defec tive PSU 2 Remove the power cord from the power supply unit Note which power cord it is according to the AC numbering 58 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 Figure 37 Power Cord Numbering Fan 3 Fan 4 gt 6512 000000000 000000000 OO000d odo 000000000 000000000
69. nes provides AC failover pro tection When using the 1600W PSUs the minimum complement of power supply units to start the chas sis is 2 and the chassis will continue to run at full capacity with only 2 PSUs The system should continue to run and allow a hot swap of a defective PSU Should there not be enough power to keep all of the leafs running MLNX OS may power down some leafs If this happens it may be necessary to reboot the chassis once the defective PSU has been replaced Two simple ways to reboot is to use the reboot command in the CLI or reboot through the Web GUI 52 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 The power system will divide the current consumption by the number of working PSUs Should one of the PSUs fail the total current consumption will then be divided by the remaining working PSUs When the failed PSU is hot swapped the new PSU will ramp up and pass its share of current so that the total current is always divided by the number of working PSUs 1 Plug in the power cords to the PSUs 2 Plug the other end of the power cords into grounded outlets Make sure that the outlets and circuits will not be overloaded Spread out the load over at least two or three circuits or use a 3 phase circuit Figure 33 Multiple Power Inlets Electric Caution Notification CAUTION ACHTUNG ATTENTION Risk of electric shock and Gafahr des elektrischen Schocks Risque de choc
70. ntes sont appropri es Des enceintes lectriques m caniques et incendie adapt es doivent tre fournies par le fabricant du produit final ou par l utilisateur final 20 Cordons lectriques CA homologu s UL f Pour les prises lectriques en Am rique du Nord choisissez un cordon lectrique homologu UL et certifi CSA 3 conducteurs 18 AWG termin par une fiche moul e d une tension nominale de 125 V 15 A avec une longueur minimale de 1 5 m 6 pieds et d une longueur maxi male de 4 5 m 18 pieds Pour les prises lectriques en Europe choisissez un cordon lectrique harmonis inter nationalement et marqu lt HAR gt 3 conducteurs d un diam tre de fil minimum de 0 75 mm2 d une tension nominale de 300 V avec une gaine isol e en PVC Le cordon doit avoir une fiche moul e d une tension nominale de 250 V et d une intensit nominale de 10 A Mellanox Technologies 89 Co ap ng Rev 1 5 21 40 lbs 40 70 lbs 70 121 lbs 121 lbs 18 kgs 18 32 kgs 32 55 kgs gt 55 kgs 90 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 Appendix H Installation Sicherheitshinweise Ger man 1 Installationsanleitungen Lesen Sie alle Installationsanleitungen bevor Sie das Ger t an die Stromversorgung anschlie en 2 bertemperatur Dieses Ger t sollte nicht in einem Bereich mit einer Umgebungstemperatur ber der maximal empfohlen
71. o have at least two people for the duration of the installation proce dure Use a mechanical lift to raise this chassis If not use enough manpower to ensure the safety and wellbeing of all of the people involved in the installation 36 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 3 6 2 2 Installation and Cable Management Kit Parts Parts for installing the shelf e 1 shelf 16 M6 bolts for the caged nuts 8 for the shelf and 8 for the faceplate e 12 caged nuts 4 for the shelf and 8 for the 2 Shelf rail slides faceplate Parts for installing the chassis 2 chassis rail slides e 4 handles 8 M 5 pan head bolts 8 allen head screws 2 flat 4 hole metal spacers e allen wrench 8 split lock washers 4 ock nuts for handles Parts for installing the cable manager e 1 RH cable holder e 1 LH cable holder 12 caged nuts M6 12 M6 bolts You will need 10 U of space in the rack Nine U for the chassis and one U for the shelf Figure 14 Shelf Installation Kit Parts gled icket M6 X 12 Caged nuts e 4 gt M6 X 16 bolts Ow Mellanox Technologies 37 Cc apang Rev 1 5 Installation Figure 15 Chassis Installation Parts ail Slide kaan al mall a M 5 Pan 00000000 head screws ANA GE Washer AA the handles 3 6 2 3 Container Mishandling The container has shock and tilt stickers applied These will turn red if the container has been mishandled o
72. oduct contains printed circuit boards cables and batteries According to the WEEE Directive 2002 96 EC all waste electrical and electronic equipment EEE should be collected separately and disposed of according to the directive 8 Go to the Mellanox website for detailed instructions for disassembly of the FRUs and chassis according to the WEEE Directive 9 Dispose of these pieces in a legal and environmentally friendly way 6 1 1 Removing the Chassis pa Remove the screws connecting the upper brackets to the rack 2 Remove the screws holding the chassis to the rack These screws are located in the faceplate on the spine side of the chassis Remove the upper brackets from the chassis 4 Dispose of the Chassis in a legal and environmental way en Go to the Mellanox website for detailed instructions for disassembly of the chassis according to the WEEE Directive 6 1 2 Removing the Bottom Shelf 1 Remove all of the bolts that are holding the shelf to the rack 2 Remove the shelf 3 Remove all of the caged nuts 70 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 6 2 Disposal According to the WEEE Directive 2002 96 EC all waste electrical and electronic equipment EEE should be collected separately and not disposed of with regular household waste Dispose of this product and all of its parts in a responsible and environmentally friendly way Go to the Mellanox webs
73. oles it is recommended to clean the fan unit and remove the dust from the front and rear panels of the switch using a vacuum cleaner 4 Determine which fan module is problematic by checking the status LED on each fan module 5 Remove and reinstall the problematic fan unit Make sure the mating connector of the new unit is free of any dirt and or obstacles See Section 5 4 on page 64 6 Replace the Leaf fan module LA Replace defective leaf fan modules as soon as they are identified Should any of the boards shut down due to over temperature follow the procedure starting in step 2 Mellanox Technologies 75 QR MEN Rev 1 5 TroubleShooting 8 3 3 Yellow LED for the Spine Fan on the Management Module is Lit 1 Check the MLNX OS management for confirmation and possible explanation of the alert 2 Determine which spine has a defective fan by checking the Fan LEDs on all of the spines 3 Make sure that there is nothing blocking the front or rear of the chassis and that the fan mod ules and ventilation holes are not blocked especially dust over the holes 4 If you find dust blocking the holes it is recommended to clean the fan unit and remove the dust from the front and rear panels of the switch using a vacuum cleaner 5 Remove and reinstall the fan unit of the spine Make sure the mating connector of the new unit is free of any dirt and or obstacles See Section 5 4 on page 64 6 Replace the spine fan module LA Repla
74. onnector This LED lights up when one or more ports is receiving a symbol error The LED immediately goes off until the next symbol error is received 24 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 M 2 3 2 3 2 3 2 4 2 3 3 UID LED Switch Identifier The UID LED is a debug feature that will become available to customers in the near future For details please contact Mellanox Technologies support Leaf Board Port Connector LED Assignment Above the ports are two LEDs one for the upper port and one for the lower port v Each port has a single 2 color LED Table 7 shows the link status according to the LED condition Table 7 Connector Physical and Logical Link Indications LED Condition LED Description Off No power to the port Solid Green Logical link up Flashing Green Data activity flashing speed is proportional to data transfer speed Solid Orange Physical link up Flashing Orange A problem with the physical link The LED indicator corresponding to each data port will light orange when the physical connection is established that is when the unit is powered on and a cable is plugged into the port with the other end of the connector plugged into a functioning port When a log ical connection is made the LED will change to green When data is being transferred the light will blink green SDR DDR QDR or FDR and or the link width 1X or
75. ons de biens 4 Connection d Alimentation electrique excedentaire dangers lectriques Ce produit comporte un couvercle transparent sur l espace pour l alimentation lec trique redondante Ne pas faire fonctionner le produit si le couvercle transparent n est pas solidement fix ou s il est enlev 5 Systeme de fusible neutre double p le Avertissement Syst me de fusible neutre double p le Veuillez debrancher tous les cordons d alimentation avant d ouvrir le boitier de ce produit ou de toucher un de ses composants internes 6 Orages dangers lectriques Pendant un orage il ne faut pas utiliser le mat riel et il ne faut pas brancher ou d brancher les c bles 7 Branchement d branchement des c bles InfiniBand en cuivre Les c bles InfiniBand en cuivre sont lourds et ne sont pas flexibles il faut donc faire tr s attention en les branchant et en les d branchant des connecteurs Consultez le fab ricant des c bles pour connaitre les mises en garde et les instructions sp ciales 87 Rev 1 5 8 Risque de choc et de danger Risque de choc et de danger e lectriques Le de branchment d une seule alimentation stabilise e ne de branch unique ment qu un module Alimentation Stabilise e Pour isoler completement le module en cause Il faut de brancher toutes les alimentations stabilise es Risk of electric shock and energy hazard The PSUs are all independent
76. otiation N Initial configuration must be done on all of the management modules The first man agement module you configure will be the master 2 6 4 c SB The USB port can be used to upload new SW using any storage device that has a USB connector This interface is USB 2 0 2 6 5 Reset RST The Reset button resets the chassis management module when the button is pushed When the button is held down for 15 seconds the management module is reset and the password deleted DO NOT use a sharp pointed object such as needle or push pin for pressing the Reset button Sharp objects can cause damage use a flat object such as a paper clip Mellanox Technologies 31 AA Rev 1 5 Hardware Figure 13 Reset Button CONSOLE MGT e RST PSU S FANS L FANS MASTER a h IA This button resets the CPU of the management module A quick push of this button performs this reset When the reset button is pushed on the master management module this management mod ule is reset becoming the slave and the other management module becomes the master If there is only one management module in the chassis all of the leafs and ports are reset by bringing them down and powering them up when the reset button is pushed When the button is held down for 15 seconds the management module is reset and the password is deleted You will then be able to enter without a password and make a new password for the user admin 32 Mellanox Technolog
77. r out from the PSUs chassis failures querying for switch serial numbers revisions Software version e SwitchX FW version switch temperatures The manager also has the ability to burn new firmware and upgrade software on the switch 72 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 7 1 InfiniBand Subnet Manager The InfiniBand Subnet Manager SM is a centralized entity running in the switch It dis covers and configures all the InfiniBand fabric devices to enable traffic flow between those devices The SM applies network traffic related configurations such as QoS rout ing partitioning to the fabric devices You can view and configure the Subnet Parameters SM via the CLI WebUI Each InfiniBand subnet needs one subnet manager to discover activate and manage the subnet An InfiniBand network requires a Subnet Manager to be running in either the Infiniband switch itself switch based or on one of the nodes which is connected to the Infiniband fabric host based 7 2 Fabric Inspector Diagnostics Fabric Inspector is a plug amp play software for fee within MLNX OS displaying and fil tering all identified systems and nodes within the fabric Fabric Inspector includes a complete set of tools for fabric wide diagnostics to check node node and node switch connectivity and to verify routes within the fabric Advanced filtering allows creating filtering rules on a system wide ba
78. r roughly handled Upon receipt of the container look for and inspect the shock and tilt stickers to confirm that they have not tripped If one or more are red notify the shipper and Mellanox This on its own does not indicate damage to the contents But be sure to carefully inspect the contents if any of the shock and tilt stickers have tripped 38 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 Figure 16 Shock and Tilt Stickers a Stickers unaffected by shipping Stickers showing excessive shock or tilt 3 6 2 4 Opening the Container 1 Before starting the procedure put the ESD strap on and connect it to a valid ground Rev 1 5 Installation 2 Open the crate by unscrewing the sides and top of the crate Container screws Y It is highly recommended to have a screw gun or electric screwdriver for this step 3 Unscrew the sides of the crate 4 Remove and put aside the box 5 Visually inspect the chassis make sure that thereis no visible damage e 4PSUs are installed for the chassis e all 4 fans are installed 6 Remove all protective plastic film from all sides and top of the chassis 7 If you are not using a mechanical lift to install the chassis reduce the weight of the chassis by removing all of the power supply units and fan units and put aside for reinstallation after the chassis is installed in the rack
79. range of 100 240 volts AC Remove and reinstall the power cable Check the circuit breakers to be sure that the breaker has not tripped Check that the power cable is good Replace the power cable If the AC power LED is green but the OK power LED is off or the FAIL LED is on Replace the PSU AAA de OX ko 8 2 Leaf Board The power LED for the Leaf board is off 1 Make sure that all of the PSUs are showing DC OK 2 Uninstall and reinstall the Leaf board 3 When the Yellow LED is on this indicates a fault in the board uninstall and reinstall the Leaf board 4 If uninstalling and reinstalling the Leaf board does not work burn the latest FW on the Leaf board and uninstall and reinstall the Leaf board 5 Replace the Leaf board with a new one hl Should any of the boards shut down due to over temperature wait 5 minutes and then follow the procedure starting with step 2 gt The Physical link LED for the InfiniBand connector does not come on 1 Check that both ends of the cable are connected 2 Check that the locks on the ends are secured 3 Make sure that the latest FW version is installed on both the HCA card and the switch 4 If media adapters are used check that the all connections are good tight and secure 5 Replace the cable The Activity indication does not come on 74 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 Check that the Subnet Manager has been
80. s 73 7 3 Accessing the CPU via the Ethernet Connector 73 7 4 Upgrading SOMWAIC 3x a De Spes GAN NOR BR re 73 Chapter 8 TroubleShooting 74 S T Power Supply Uniti eo aa are a 74 8 2 SAMBO ONG uv a A e e di o A ee in mU e 74 8 3 Management Module 2s reir en 75 8 3 1 Yellow Status LED for the Chassis on the Management Module is Lit 75 8 3 2 Yellow LED for the Leaf Fan on the Management Module is Lit 75 8 3 3 Yellow LED for the Spine Fan on the Management Module is Lit 76 8 4 Spine BO ana ns oer eub e aha oe PETRI be arr 76 8 5 MLNX OS Software sitiada ee tadas xe qued 76 Appendix A Specification Data 77 Ad EMI Gerlitication a aa ica 79 4 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 A 2 Approved Cables da Naa a dors d aa DO e dt 79 AS EMC Certifications s ns rain 79 Appendix B Thermal Threshold Definitions 80 Appendix C Calculating the Weight of a Customized Chassis 81 Appendix D Calculating the Power of a Chassis 82 Appendix E QSFP Interface 83 Appendix F Replacement Parts Ordering Numbers 85 Appendix G Avertissements de s curit d installation French 87 Appendix H Installation Sicherheits
81. s parts in a responsible and environmentally friendly way pai 23 Country of Norway Power Restrictions This unit is intended for connection to a TN power system and an IT power system of Norway only Mellanox Technologies 19 Rev 1 5 Hardware 2 2 Power Supply Redundancy The MSX6512 platform comes standard with four power supplies and has two order options e MSX6512 4R N 1 1000W output per PSU e MSX6512 NR N N 1600W output per PSU 2 2 1 1000W Power Supply Units The 1000 W power supplies deliver 1000W at 48V The input to each of these power supplies requires 1214 46W at 220V in order to output 1000W With 1000W PSUS the only redundancy option is N 1 In this configuration 1PSU Power Sup ply Unit can be extracted without bringing down the system When using the 1000W PSUs the minimum complement of power supply units is 4 and the chassis will continue to run at full capacity with only 3 PSUs 2 2 2 1600W Power Supply Units When using the 1600W PSUs the minimum complement of power supply units is 2 and the chassis will continue to run at full capacity with only 2 PSUs The 1600W PSUs can implement two redundancy options e N 1 configuration The chassis when supplied by a single power grid can be configured for N 1 times 2 This means that all PSUs are supplied from a single power source usually the commercial electric grid This enables 2 power supply redundancy N N configuration N N with 1600W PSUs wi
82. shelf adds 44 5mm to the height 120 kg 265 LBS full configura tion 48 kg 105 LBS empty configu ration 83 94 kg 185 LBS shipped con figuration Mounting Center of Grav ity Measured from the bottom left corner as one faces the switch ports Max Air Flow 19 Rack mount CoGh 311 8 mm from bottom of chas sis CoGw 222 mm from left side surface CoGd 328 14 mm from port end sur face Measured from the bottom left corner as one faces the switch ports ellanox Technologies Co ap ng BIDEN Through leafs 16 59M3 min 585 9 CFM Through spines 9 48 M3 min 334 8 CFM SerDes Speeds Connector Seres naga 10 20 40 Gb s or 56 Gb s per Types QSFP Connector Types port Sound Level Sound Level Ports Ports 76 db A 216 ports Power and Environmental Input Voltage Input Voltage Management Management 100 240 VAC 50 60Hz CPU PowerPC 460EX Temperature Operating 0 to 45 Celsius Non operating 40 to 70 Celsius Cable power QSFP MAX 2W Humidity 5 95 non condensing Humidity TYP 1 5W Operating 77 Rev 1 5 Power numbers Total Power Consumption Power Con sumption Spine Typical FDR14 Passive cables 2287W Typical FDR14 Active optical cables 2846W including QSFP at 1 5W Max FDR14 Passive cables 2390W Max FDR14 Active optical cables 3047W including QSFP at 2 0W Typical 108W include 2 Fans Max 117W
83. sis between nodes or port connections based on traffic patterns and user assigned system names GUIDs 7 3 Accessing the CPU via the Ethernet Connector Once the initial configuration is completed the management tools can be accessed through SSH Telnet WEB SNMP XML 7 4 Upgrading Software The new software and firmware update is available to the user from the Mellanox Sup port website Copy the update to a known location on a Remote server within your LAN Use the CLI or the GUI in order to perform the Software upgrade For further informa tion please refer to the Mellanox OS user manual 99 an earlier version than the minimum that the new version of the software can work with then the chassis management system may require up to 45 minutes to update all of the ka FW images in all of the leafs and spines P If Mellanox OS is updated and the FW image in the leafs and spines of the chassis is Mellanox Technologies 73 Co ME Rev 1 5 TroubleShooting 8 TroubleShooting 8 1 Power Supply Unit If the Power supplies cannot supply enough power the management module may shut down the system 5 As each PSU is plugged in make sure that the green power LEDs on the PSU comes on If the AC power LED is off 1 Check that the power cable is the correct power cable for your country Check that the power cable is plugged into a working outlet Check that the power cable has a voltage within the
84. started 8 3 Management Module 8 3 1 Yellow Status LED for the Chassis on the Management Module is Lit 1 Check the MLNX OS management for confirmation and possible explanation of the alert 2 Reset the master management module by pushing the rest button If you have two management modules installed this will convert the master management module to the slave and convert the slave to the master If there is only one management module in the chassis all of the leafs and ports are reset by bringing them down and powering them up when the management module is removed Make sure the S Fans and L Fans LEDs are green Make sure that the spine and the leafs both have the same version of FW Reburn the FW and remove and reinstall the management module Dy Me E If you are running the chassis with only one management module remove and rein stall the management module Make sure the mating connectors of the unit are free of any dirt and or obstacles See Section 5 5 on page 67 7 If you are running the chassis with only one management module replace the man agement module 8 3 2 Yellow LED for the Leaf Fan on the Management Module is Lit 1 Check the MLNX OS management for confirmation and possible explanation of the alert 2 Make sure that there is nothing blocking the front or rear of the chassis and that the fan modules and ventilation holes are not blocked especially dust over the holes 3 If you find dust blocking the h
85. t detected User should check individual power sup plies for fault indications SPINE FANS Off No power to fan Green STATUS Green Nominal operational Red One or more of the spine fans is bad User should check individual spine fan LEDs for fault indications LEAF FANS Off No power to fan Green STATUS Green Nominal operational Red One or more of the leaf fans is bad User should check individual leaf fan LEDs for fault indications MNGI Off Green MASTER no power STATUS this management module is not installed this management module is not the master Green Management module is operating as a master MNG2 Off Off MASTER no power STATUS this management module is not installed this management module is not the master Green Management module is operating as a master 28 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 2 3 5 Management Module LED Indicators Figure 9 Management Module Status Indications m m an n r m m ICON ya IN Status The management module LEDs display the switch system operating conditions Table 13 LEDs Display for Normal Operation qn aen Normal LED Condition Description State STATUS Off No Power Green This LED Green System is up and running shows the sta Yellow System warning Attention needed such as overheat tus of the chas ing sis Red System not operational
86. t with the Chassis family and switch chip generation When hot swapping any of the units it is necessary to wait 1 minute after removing the defective part before inserting the new part This is necessary so that the manage ment module will start a new cycle checking through the leafs and spines for the FW versions gt Ww The leaf boards are numbered from top to bottom with corresponding numbers displayed to the outside of the leafs vertically along the side panel Figure 40 Leaf Board Numbering aa H E MU 3a v y 154 Vis 17A Vig Ba vis a Vie 1 L1 L2 L3 LA gene men TE OS L11 ng L12 bis 5 2 1 Extracting a Leaf Board Each leaf board has an ejector that locks the board in place and serves as a lever for seating or extracting see Figure 51 1 Run the shut down command no power enable lt module gt For example to shut down leaf 16 run the command below switch 1 Orca648 master config no power enable L16 60 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 Disconnect all cables connected to the leaf Push the latch to unlock the ejector from the chassis Open the ejector until it is 45 degrees from the leaf HS oe D Pull out on the leaf Figure 41 Ejector Latch Pull the leaf out of the chassis Leaf Leaf in Push the latch release 0 Pup Ejector Ah The board is short therefore do not let
87. tely necessary to con nect the grounding post Make sure the connections are solid and permanent If you choose to not use the ground screw make sure that the rack is properly grounded and that Rev 1 5 Installation there is a valid ground connection between the chassis of the switch and the rack Test the ground using an Ohm meter Figure 32 Ground Connection AU ESD connector Ground Post 3 7 Power Connections The switch includes integrated hot swap power supplies which support up to 4 load sharing 1000W or 1600W supply units The slots for the power supply units PSUs are on the spine side The left side has odd numbered PSUs and the right side has even numbered PSUs Each PSU has a dedicated AC inlet This design enables the optional use of separate main and backup AC feeds The input voltage is Autorange 100 240 VAC 50Hz or 60Hz The output voltage for the PSUs is 48V The power cords should be standard 3 wire AC power cords including a safety ground 3 7 1 Powering Up the Switch Platform Make sure that the power cords are compatible with your outlets Power cords for dif b ferent countries can be ordered from Mellanox SS The chassis in N 1 mode must be started with a full complement of PSUs thereafter it can run on one less than the total number of PSUs This final PSU is redundant and allows for hot swap ping a PSU should one fail Connecting the PSUs to different AC li
88. the connector side 2 5 QSFP Cable Power Budget Classification All SX6512 QSFP switches are designed for active cables with a max power per module of 2 0W This is power level 2 according to the QSFP Public Specification 2 6 Management Module Interfaces The switch system requires at least one management module The management module has five interfaces to connect to the SX6512 They are e 11 port e CONSOLE port this is an RS232 connector for connecting to a host machine MGT this is an Ethernet connector e 1 USB port e RST reset button Figure 12 Management Module Interfaces m CONSOLE MGT eb RST PSU li 30 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 2 6 1 12C This interface is for Debug and Troubleshooting only This interface is for FAEs only 2 6 2 CONSOLE The CONSOLE port is used during the installation process to configure the chassis for remote management Connect this port to a local host using the harness supplied with the chassis See the Installation Guide for the initial configuration procedure 2 6 3 MGT Management The MGT port is an Ethernet port for remote management Any remote terminal con nected to the Ethernet port can then be used to manage the fabric and chassis Each Ethernet connector gets connected to Ethernet switches These switches must be configured to 100M 1G auto neg
89. tricos y mec nicos y contra incen El fabricante del producto final o el usuario final deber n suministrar A dio 12 Eliminaci n de equipos A A La eliminaci n definitiva de este equipo se debe efectuar conforme a todas las leyes y reglamentaciones nacionales K 13 C digos el ctricos locales y nacionales LA Este equipo se debe instalar conforme a los c digos el ctricos locales y nacio nales 96 Mellanox Technologies InfiniBand FDR Switch Platform Hardware User Manual Rev 1 5 14 Cable de alimentaci n homologado por UL y con certificaci n CSA N En conexiones de America del Norte seleccionar un cable de alimentaci n a homologado por UL y con certificaci n CSA de tres conductores 16 AWG termi nado en un enchufe moldeado con capuch n de 125 voltios nominal 13 A con una longitud minima de 1 5 metros pero no m s de 4 5 metros En conexiones europeas seleccionar un cable de alimentaci n armonizado internacionalmente y marcado lt HAR gt de tres conductores hilo de 1 0 mm2 como minimo 300 voltios nominal con cobertura protectora aislante de PVC El cable debe tener un enchufe moldeado con capuch n de 250 voltios nominal 10 A 15 Anadir conexi n a tierra Antes de conectar el dispositivo ala linea de alimentaci n los tornillos del terminal de la puesta a tierra de protecci n del dispositivo se deben conectar a la puesta a tierra de protecci n de la instalaci n del edificio In