Home
User Manual
Contents
1. UPS www visionups com N 00 4 SYSTEM DESCRIPTION 4 1 Front panel 1 Mains power switch 2 LED Indicators Mains mode The green LED is lighting 650 1300VA The left green LED is lighting amp the 1st to 4th green LED are gradually lighting and in line with the load level 1600 2200VA Battery mode The yellow LED is flashing 650 1300VA The left green LED is flashing amp the 1 to 4 green LED are gradually lighting and in line with the autonomy level 1600 2200VA Fault mode The red LED is lighting 3 LCD 1100 1300VA A ii ee ee ee ee ee ee ee ee ee eee ee ee ee Ui 4 2 Back panel 1 Input mains power supply 2 Output receptacles 3 USB amp RJ11 data communication 4 USB amp RS232 data communication 5 RJ45 6 Circuit breaker ke pe e e e e e m em em e e e e e e o 0 O So e eee i m ue 0 09 O 00 BUDGET PRO series 650 2200VA UPS www visionups com 5 INSTALLATION amp OPERATION 5 1 Unpacking and control Remove the packaging from the UPS and inspect it for eventual transport damage If any damage is discovered repack the unit and send it back to the seller 5 2 Charging before first use Tis unit was sent ex factory with its internal battery fully charged anyhow it can discharge during the transportation That s why it has to be charged before firs
2. User Manual Budget Pro series 650 2200VA EOS650 2200 Uninterruptible Power Supply INDEX Te MAHOU CHOW TTT 2 2 Safety INSWUCHONS costcorrrarminrerisctnbrr drid Setncna ga dades lorca 2 o E UE o ADE REIS a icon Cad aca saE 3 4 System description penpsstastia crises ndoncrea gia canoas adding ido de pndai andem g arabica da aplicadas 4 cN Seine PANO A e e o en 4 B25 BACK DANG IPP OA IP o 4 Oy IMSTAlMalOA SSODELANON serprrtos cos unir io Pina a lps els aE 5 9 1 Unpacking and CONTO asencrrosostrecccin totor patin sap EEEE 5 5 2 Charging before first USO cci cece cece eect ence eee eee eee ened teat este rear aerea 5 A e eta assada a dana re saida ia 5 BAC OWE COIN AA A A 5 AAA e ne OA 5 5 6 Cold start in battery mode 5 QUIS PP o A Ie 6 1 INTRODUCTION This UPS is specially designed for personal computers with multi functions Its light weight and compact design fits perfectly into limited workspaces The UPS input is equipped with automatic voltage regulation boost and buck AVR to stabilize input voltage range It has also a built in cold start function which enables the UPS for start up without mains supply Although it s a small UPS it disposes the main features listed below control by microprocessor guarantees a high reliability equipped with automatic voltage regulation boost and buck AVR green power function for energy saving cold start function automatic restart while mains sup
3. aintaining the battery lifetime we advise an ambient operating temperature of 20 C to 25 C Ensure during the installation of the appliance that the sum of the residual current of the UPS and of the connected load does not exceed 3 5mA Caution of electric shocks Even when the unit is disconnected from the mains dangerous voltages could be achieved via power supply from the battery For that raison interrupt the battery on its plus and minus poles when maintenance and servicing activities are necessary and undertaken The mains socket outlet that supplies the UPS shall be installed near the UPS unit and shall be easily accessible 3 SPECIFICATIONS LED Model amp LCD Model BP650 BP850 BP1100 BP1300 BP1600 BP2200 BP650D BP850D BP1100D BP1300D BP1600D BP2200D 650VA 850VA 1100VA 1300VA 1600VA 2200VA 220 230 240 Vac 162 290 Vac 60 50 Hz automatic recognition Capacity Voltage Voltage range Frequency range 230 Vac 10 no block sinus 50 60 Hz 1 typically 2 a 6 ms Voltage in battery mode Frequency in battery mode Transfer time Batteries Recharge time 6 8 hours to reach 90 of capacity Number and type of battery Mains mode AC Battery Modus Overvoltage overload Battery mode Weak autonomy Overload Replace batteries Fault continuously sounding Dimensions mm W x D x H 158 x 380 x 198 Net weight kg 4 25 8 111 11 5 lt 90 without condensation 3 BUDGET PRO series 650 2200VA
4. en 2 The battery voltage is too low 3 Battery fault because of too high Operating temperature or because of malfunction of the battery 1 Charge the battery during 8 hours 2 Replace the battery with a new one of same type 3 Press the power switch again Verify if the connected load is in accordance with the denoted performance see specifications 1 Remove some non critical loads 2 Charge the battery during 8 hours or more 3 Replace the battery with a new one of same type Mains power is normal but The Power cord is loose Reconnect the power cord properly and the yellow LED is flashing firmly If any abnormal situations occur that are not listed above please contact immediately the client service BUDGET PRO series 650 2200VA UPS www visionups com
5. ger electric appliances to the output connectors The electricity consumption would cause an overload and possibly even the damage of the UPS To reduce the risk of overheating do not cover or block the vent of the UPS unit do not expose the appliance to direct sunlight do not install it near heat emitting appliances such as space heaters or furnaces ovens Pull the mains plug out of the socket before cleaning Do not use liquid or spray detergents Do not expose the batteries to fire because they may explode Do not open and or damage the batteries on their outside released electrolyte lead acid accumulator is harmful to skin and eyes It may be toxic A battery holds the risk of electric shocks and short circuits The following precautions should be considered when working with batteries 1 Remove watches rings or other metal objects from your hands 2 Use tools with insulated handles 3 Wear rubber gloves and rubber boots 4 Do not deposit tools and or metal parts on the battery 5 Disconnect the appliance from the mains each time you are connecting or disconnecting the battery terminals The maintenance of the batteries should be executed by battery knowledgeable personnel Observe the recommended and necessary precautions Keep unauthorised personnel away from the batteries When the batteries are replaced utilize the same quantity and type of sealed lead acid battery The ambient temperature may not exceed 40 C For m
6. ply recovery compact size light weight provides mains supply overload protection 2 SAFETY INSTRUCTIONS This UPS uses voltages that may be dangerous Do not attempt to disassemble the unit it contains no user serviceable parts Repairs should only be executed by plant service The battery voltage is 12Vdc These are internal sealed maintenance free 6 cells lead acid batteries The UPS must be connected to a mains socket with circuit breaker Connect the appliance only to a mains socket with grounding Incase of an emergency press the OFF button and pull the mains plug for interrupting completely the power supply to the UPS Do not let attain any liquids or foreign objects into the UPS appliance that s why no beverage or other liquid containing vessels should be placed on or near the appliance This unit is intended for installation in a controlled environment temperature and humidity Do not install it in locations with standing or flowing water or excessive humidity Do not plug the input cable of the UPS in its own output Do not connect multiple plugs or surge protections to the UPS unit Only connect computer related elements to the UPS unit DO NOT CONNECT medical applications or life support equipment BUDGET PRO series 650 2200VA UPS www visionups com DO NOT CONNECT AS WELL laser printer labelling machines copy machines generators vacuum cleaners drain pumps microwave ovens or other lar
7. t use Turn on the UPS plug it into an appropriate power supply and allow the UPS to charge totally by leaving it plugged in for at least 6 hours with no load no electrical devices such as computers monitors etc connected a hours 5 3 Placement Install the UPS unit in a protected environment that provides adequate ventilation around the unit and that s free from excessive dust corrosive vapours and conducting polluting substances Do not operate your UPS in an environment where the ambient temperature or humidity is high 5 4 Connection Plug the UPS into a 2 pole grounded mains socket phase and neutral Afterwards connect by means of the delivered cable one computer or computer related device to each connection jack on the back side of the UPS 5 5 Turn On Off To turn the UPS on press the power switch To turn the UPS off press the power switch again 5 6 Cold start in battery mode All UPS appliances are equipped with a cold start function in battery mode To start the UPS when mains power is not available simply press the power switch gt BUDGET PRO series 650 2200VA UPS www visionups com 6 TROUBLE SHOOTING No LED indication on the 1 The battery is weak front panel display 2 Battery fault 3 The power switch is not pressed Alarm buzzer beeps Overload of the UPS continuously when mains supply is normal When the power failures 1 Overload of the UPS back up time is short
Download Pdf Manuals
Related Search
Related Contents
LG 55EC9300 Specification Sheet Sony LCS-WR2AM Marketing Specifications Memorex Mi1111 L`objet effectivement enseigné en classe de français par des 製品の最小曲半径はR30mm(長さ方向)です。 縦方向の Lithonia Lighting 11790 BZ M4 Installation Guide IMPORTANT WARNINGS La Plate-Forme décembre 2012 - Sainte-Rose-du-Nord INSTRUÇÕES DE MONTAGEM - Pfaff Industrial Machinery Copyright © All rights reserved.