Home
User Manual - Chauvin Arnoux Group
Contents
1. CAT IV Phase Rotation Meter Model 6610 For measurements performed on circuits directly connected to the electrical distribution system Examples are measurements on household appliances or portable tools For measurements performed in the building installation at the distribution level such as on hardwired equipment in fixed installation and circuit breakers For measurements performed at the primary electrical supply 1000V such as on primary overcurrent protection devices ripple control units or meters 1 3 Receiving Your Shipment Upon receiving your shipment make sure that the contents are consis tent with the packing list Notify your distributor of any missing items If the equipment appears to be damaged file a claim immediately with the carrier and notify your distributor at once giving a detailed description of any damage Save the damaged packing container to substantiate your claim 1 4 Ordering Information Phase Rotation Meter Model 6610 Cat 2121 12 Includes meter with attached test leads black red and blue with large alligator clips soft carrying case one 9V battery and user manual 1 4 1 Accessories and Replacement Parts Case Replacement soft carrying Cat 5000 41 Order Accessories and Replacement Parts Directly Online Check our Storefront at www aemc com for availability 4 Phase Rotation Meter Model 6610 C
2. CATIVeOV 45 65Hz CAT 1000 75 1000VAc ots 5 SL N AIL1 B L2 CIL3 eNO 9 N PHASE ROTATION METER 73 o OO o e Live Open LED phase indicators ON OFF power button LED brightness button Phase sequence LEDs Battery LED flashes if low Phase Rotation Meter Model 6610 CHAPTER 3 OPERATION 3 1 Making Measurements Before proceeding with a measurement read the safety notes on page 2 1 Press the power button to turn on the instrument All of the LEDs will flash during the first 2 seconds Only the Green Battery OK LED will stay on at the completion of the self test Do not use the instrument if any of the LEDs do not function properly 2 Position the clamp on each conductor to be measured so that the point of the triangle mark Y on each jaw of the measurement clip is centered on each measured conductor Phase Rotation Meter Model 6610 7 3 Connect three clips as shown A L1 BLUE Black L1 to Phase A Red L2 to Phase B Blue L8 to Phase C 4 Measure a live insulated conductor carrying 75VAC or more first to confirm each live LED lights up 5 The presence of live wires and phase sequence are confirmed by LED indication and buzzer as soon as detection is completed 6 A B and C LEDs are always lit up when the instrument detects a live phase 7 ABC Green LED ON correct phase sequence BAC Red LED ON incorr
3. E PHASE ROTATION METER NON CONTACT INSTRUMENTS User Manual SS SS SS SS SS SS SS SS SRS 7 SS x Statement of Compliance x Chauvin Arnoux Inc d b a AEMC Instruments certifies that this instrument has been calibrated X 3 using standards and instruments traceable to 4 international standards t He We guarantee that at the time of shipping your je X instrument has met its published specifications x Ni 4 The recommended verification interval for this At X instrument is 12 months and begins on the date x of receipt by the customer For verification please x X use our calibration services Refer to our repair Ab x and calibration section at www aemc com X x jj Serials He Catalog 2121 12 IK XC x Model 6610 x I X Please fill in the appropriate date as indicated x C x Date Received X J jt Date Calibration Due X Jj ld At C Chauvin Arnoux Inc x X d b a AEMC Instruments x X AEMC www aemc com x Table of Contents 1 INTRODUCTION 2 1 1 International Electrical 3 1 2 Definition of Measurement Categories NEC 1 3 Receiving Your Shipmioent niter ette 3 1 4 Ordering Information ote acere 4 1 4 1 Accessories and Replacement Parts 4 2 PRODUCT FEATURES 5 254
4. HAPTER 2 PRODUCT FEATURES 2 1 Description The Phase Rotation Meter Model 6610 is an essential tool for any instal lation inspection and maintenance facility The Model 6610 is designed to identify phase rotation on 3 phase systems and identify live and open de energized phases The phase order is determined as soon as the leads are connected Presence of live wires and phase sequence are informed by LED indication and a buzzer as soon as detection has occurred The Model 6610 is ideal for installing rotating machinery or motors and for checking generator output 2 2 Features Non contact no metal contact points Operating voltage 75 to 1000VAc Frequency range 45 to 65Hz Phase rotation LED indicators ABC or BAC Bright LED indication Live or Open Phase A B C Includes three attached color coded test leads with alligator clips for easy connection to the device under test Clipping the non electrical contact alligator sensor clips onto the insulation of the phase conductor promotes operator safety during measurement Low battery indicator Back cover includes a magnet feature that can mount the instrument onto an AC distribution panel for easy measurement EN61010 1 1000V CAT Ill 600V CAT IV Phase Rotation Meter Model 6610 5 2 3 Applications Verify proper phase wiring Detect open or de energized phases Determine correct wiring for proper rotation on motors pumps etc 2 4 Control Features m Po N
5. JDescriplion onere eb et a ete eels 5 2 2 Featil6S sinet ieri pico beue CU E Ova die ode RENNES 5 2 9 JADDIICATOFIS c crier tee i ct eren ee eee 5 2 4 CorittollFeatufes iecit ro conconssaceunsensencepceneszendocantnn 6 3 OPERATION 7 3 1 Making Measurements 7 3 2 Live Wire COCK ss eere rcr ete dee 9 4 MAINTENANCE 4 1 Replacing the Battery 4 2 Cleaning rit coti hr esr dtt Oei 5 SPECIFICATIONS 11 Repaitiand Calibration iot cesa tree ts tbe cede 12 Technical and Sales Assistance 12 irnited Warrant u u 13 Warranty R6palls cct oen et pe dre d ei De tuae 13 Phase Rotation Meter Model 6610 1 CHAPTER 1 INTRODUCTION Precautions Before Use These safety warnings are provided to ensure the safety of personnel and proper operation of the instrument To ensure safe operation and usage of this instrument follow instruc tions in this manual Failure to observe Warnings may result in SEVERE injury or death It is recommended for use in distribution level and fixed installations as well as lesser installations and not for primary supply lines over head lines and cable systems Do not exceed the maximum overload limits per function see speci fications nor the limits marked on the instrument itself Never apply more than 600V CAT IV 1000V CAT III between the tes
6. be scheduled back to our factory Service Center at one year intervals for recalibration or as required by other standards or internal procedures For instrument repair and calibration You must contact our Service Center for a Customer Service Authorization Number CSA This will ensure that when your instrument arrives it will be tracked and processed promptly Please write the CSA on the outside of the shipping container Ship To Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 800 945 2362 or 603 749 6434 Ext 360 Fax 603 742 2346 or 603 749 6309 E mail repair aemc com Or contact your authorized distributor NOTE You must obtain a CSA before returning any instrument Technical and Sales Assistance If you are experiencing any technical problems or require any assistance with the proper operation or application of your instrument please call mail fax or e mail our technical support team Chauvin Arnoux Inc d b a AEMC Instruments 200 Foxborough Boulevard Foxborough MA 02035 USA Phone 800 343 1391 508 698 2115 Fax 508 698 2118 E mail techsupport aemc com www aemc com NOTE Do not ship Instruments to our Foxborough MA address 12 Phase Rotation Meter Model 6610 Limited Warranty The Phase Rotation Meter Model 6610 is warranted to the owner for a period of one year from the date of original purchase against defects in manufacture This
7. e instrument is OFF e Loosen the screw that secures the battery compartment cover and open cover e Replace the battery with a new 9V alkaline battery Ensure battery is inserted with the correct polarity e Install the battery compartment cover and tighten the screw 4 2 Cleaning e fthe case needs cleaning do not use any alcohol or oil based clean ers Preferably use soapy water with a damp cloth or sponge e Dry immediately after cleaning Avoid water penetration into the elec tronic module 10 Phase Rotation Meter Model 6610 CHAPTER 5 SPECIFICATIONS ELECTRICAL MECHANICAL Measurement Principle Static induction Operating Voltage 75 to 1000Vac Frequency Range 45 to 65Hz Auto Off 5 minutes after power on if not in use Power Source 1 x 9V alkaline battery Low Battery Warning lt 7V 0 2V Current Consumption 20mA ENVIRONMENTAL Dimensions 5 0 x 2 8 x 1 8 128 x 72 x 46mm Weight 0 82 Ibs 3759 including battery Cable Length 2 5 ft 600mm approx SAFETY Safety Rating Operating Temperature 14 to 122 F 10 C to 50 C Storage Temperature 4 to 140 F 20 to 60 C Humidity 80 RH IEC61010 1 1000V CAT Ill 600V CAT IV EN61326 1 CE Mark Yes Specifications are subject to change without notice Phase Rotation Meter Model 6610 11 Repair and Calibration To ensure that your instrument meets factory specifications we recommend that it
8. ect phase sequence 8 The maximum cable diameter that the measurement clips can connect to is 1 18 inches 30mm 8 Phase Rotation Meter Model 6610 3 2 Live Wire Check STATE INDICATION Live Phase with A B C LEDs are ON Missing Ground Earth line LED does not light up for missing Ground Earth line Ground Earth line Delta connection Positive phase Phase with flashing LED Ground Earth phase Green ABC LED ON The circuit under test is phased correctly The buzzer sounds intermittently Reversed phase Red BAC LED ON The circuit under test is reverse phased The buzzer sounds continuously Detection Indicators A B C LEDs ON Indicates a live phase LEDs OFF Indicates an open or de energized phase Green ABC LED ON Correct phase sequence Phase Rotation Meter Model 6610 Red BAC LED ON Incorrect phase sequence CHAPTER 4 MAINTENANCE Use only factory specified replacement parts AEMC will not be held responsible for any accident incident or malfunction following a repair done other than by its service center or by an approved repair center Disconnect the instrument from any electrical source before replacing the battery or cleaning the instrument 4 1 Replacing the Battery When low battery LED flashes replace with new batteries To replace the battery perform the following steps e Remove all clips from any conductor and make sure th
9. ial NOTE You must obtain a CSA before returning any instrument Phase Rotation Meter Model 6610 13 INSTRUMENTS 07 15 99 MAN 100375 v4 Chauvin Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 603 749 6434 e Fax 603 742 2346 www aemc com
10. limited warranty is given by AEMC Instruments not by the distributor from whom it was purchased This warranty is void if the unit has been tampered with abused or if the defect is related to service not performed by AEMC Instruments Full warranty coverage and product registration is available on our website at www aemc com warranty html Please print the online Warranty Coverage Information for your records What AEMC Instruments will do If a malfunction occurs within the one year period you may return the instrument to us for repair provided we have your warranty registration information on file or a proof of purchase AEMC Instruments will at its option repair or replace the faulty material REGISTER ONLINE AT www aemc com Warranty Repairs What you must do to return an Instrument for Warranty Repair First request a Customer Service Authorization Number CSA by phone or by fax from our Service Department see address below then return the instrument along with the signed CSA Form Please write the CSA on the outside of the shipping container Return the instrument postage or shipment pre paid to Ship To Chauvin Arnoux Inc d b a AEMC Instruments 15 Faraday Drive Dover NH 03820 USA Phone 800 945 2362 Ext 360 603 749 6434 Ext 360 Fax 603 742 2346 or 603 749 6309 E mail repair amp aemc com Caution To protect yourself against in transit loss we recommend you insure your returned mater
11. t lead and ground earth Inspect the meter and test leads before each use Do not use any damaged parts Never ground yourself when taking measurements Do not touch exposed circuit elements Do not operate the tester in an explosive atmosphere Exercise extreme caution when measuring voltage gt 50V and current 10mA Never open the battery compartment while measuring Do not operate in a manner not specified or the instrument s protec tion may be impaired Phase Rotation Meter Model 6610 1 1 International Electrical Symbols This symbol signifies that the instrument is protected by double or reinforced insulation CAUTION Risk of Danger Indicates a WARNING and that the operator must refer to the user manual for instructions before operating the instrument in all cases where this symbol is marked Important instructions to read and understand completely Important information to acknowledge Risk of electric shock The voltage at the parts marked with this symbol may be dangerous gt oO AC Alternating current oN fan Compliance with the Low Voltage amp Electromagnetic Compatibility European directives 73 23 CEE amp 89 336 CEE In the European Union this product is subject to a separate collection system for recycling electrical and electronic components In accordance with directive WEEE 2002 96 EC 1 2 Definition of Measurement Categories CAT Il CAT
Download Pdf Manuals
Related Search
Related Contents
Libretto d`installazione e uso Roburbox 100File PDF Minox EC Instruction Manual Eglo RICCIO 2 Nokia Mediamaster 9860 S User's Manual Wind Tunnel Fog User Manual notice d`utilisation Mode d`emploi Poêle en fonte thermoIMAGER TIM 200/230 Copyright © All rights reserved.
Failed to retrieve file